Loading...
HomeMy WebLinkAboutNCG110140_Inspection_20240712 ROY COOPER M, Governor y ELISABETH BISER Secretary w µ Mirj6 WILLIAM E.TOBY vINSON,JR. Interim Director NORTH CAROLINA Environmental Quality July 12, 2024 City of Mount Airy Attention: Stan Farmer, City Manager PO Box 70 Mount Airy, NC 27030 Subject: Compliance Evaluation Inspection City of Mount Airy NPDES Certificate of Coverage—NCG110140 Surry County,North Carolina Dear Sir or Madam, Enclosed please find a copy of the Compliance Evaluation Inspection Report for the inspection we conducted at the Mount Airy WWTP on July 10, 2024. Please note that in the stormwater inspection report summary we ask that you create and maintain a S WPPP, review site map and modify as necessary, revise stormwater locations as necessary, implement appropriate preventative and good housekeeping practices to eliminate exposure, and analyze and address the drainage Swale that displays several indicators of potential wastewater and environmental impacts. The report should be self-explanatory; however, should you have any questions, please do not hesitate to contact Ashley Vikara at (336) 776-9655 or by E-mail at Ashley.vikara@deq.nc.gov. Sincerely, Tamera Epli , PE Regional E gineer Land Quality Section Enclosure: Compliance Inspection Report c: Laserfiche North Carolina Department of Environmental Quality I Division of Energy,Mineral and Land Resources tE Winston-Salem Regional Office 1 450 Hanes Mill Road,Suite 3001 Winston-Salem,North Carolina 27105 �'' � 336-776-9800 Compliance Inspection Report Permit: NCG110140 Effective: 03/01/24 Expiration: 02/28/29 Owner: City of Mount Airy SOC: Effective: Expiration: Facility: Mount Airy WWTP County: Surry US Hwy 52 S Region: Winston-Salem Mount Airy NC 27030 Contact Person:Chris Marion Title: Phone: Directions to Facility: System Classifications: SWNC, Primary ORC: Certification: Phone: Secondary ORC(s): On-Site Representative(s): Related Permits: Inspection Date: 07/10/2024 Entry Time 09.45AM Exit Time: 11:OOAM Primary Inspector:Ashley J Vikara Phone: 336-776-9655 Secondary Inspector(s): Isaiah L Reed Margeory Castellanos Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Municipal WWTP > 1 MGD, Stormwater Discharge, COC Facility Status: ❑ Compliant Not Compliant Question Areas: Storm Water (See attachment summary) Page 1 of 3 Permit: NCG110140 Owner-Facility:City of Mount Airy Inspection Date: 07/10/2024 Inspection Type :Compliance Evaluation Reason for Visit: Routine Inspection Summary: On July 10, 2024, a compliance inspection was conducted for the facility.We met with Chris Marion on site. During the inspection the following issues were noted- 1- SWPPP has not been created or maintained on site. A SWPPP shall be created and maintained in accordance with NCG 110000. 2. Additional outfalls were observed on site, not shown on the site map. Review site map and modify as necessary. Potential additional outfall locations include the access road on the west side of drying beds; the woodline northeast of biosolids loading area; perimeter west of headworks. 3. Stormwater outfalls are to be located before reaching surface waters and after any potential industrial impact. Consider revising as necessary. 4. Biosoiids accumulation was observed on asphalt adjacent to loading area. Implement appropriate preventative maintenance and good housekeeping practices to eliminate exposure. 5. Waste management equipment was observed in an area draining to a stormwater system. Implement appropriate preventative maintenance and good housekeeping practices to eliminate exposure. 6. Drainage swale west of aeration basin displayed several indicators of potential wastewater and environmental impacts (visual and odor). Analyze and address appropriately. Please give the above items attention and the facility will be reinspected on or after August 13, 2024. Page 2 of 3 Permit: NCG 110140 Owner-Facility:City of Mount Airy Inspection Date: 07/10/2024 Inspection Type :Compliance Evaluation Reason for Visit: Routine Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? ❑ E ❑ ❑ # Does the Plan include a General Location (USGS) map? ❑ 0 ❑ ❑ # Does the Plan include a"Narrative Description of Practices"? ❑ 0 ❑ ❑ # Does the Plan include a detailed site map including outfall locations and drainage areas? ❑ ❑ ❑ # Does the Plan include a list of significant spills occurring during the past 3 years? ❑ ❑ ❑ # Has the facility evaluated feasible alternatives to current practices? ❑ ❑ 0 ❑ # Does the facility provide all necessary secondary containment? 0 ❑ ❑ ❑ # Does the Plan include a BMP summary? ❑ 0 ❑ ❑ # Does the Plan include a Spill Prevention and Response Plan (SPRP)? ❑ E ❑ ❑ # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? ❑ 0 ❑ ❑ # Does the facility provide and document Employee Training? ❑ N ❑ ❑ # Does the Plan include a list of Responsible Party(s)? ❑ 0 ❑ ❑ # Is the Plan reviewed and updated annually? ❑ 0 ❑ ❑ # Does the Plan include a Stormwater Facility Inspection Program? ❑ 0 ❑ ❑ Has the Stormwater Pollution Prevention Plan been implemented? ❑ 0 ❑ ❑ Comment: See summary for details. Qualitative Monitorinq Yes No NA NE Has the facility conducted its Qualitative Monitoring? ❑ 0 ❑ ❑ Comment: See summary for details. Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? 0 ❑ ❑ ❑ #Were all outfalls observed during the inspection? 0 ❑ ❑ ❑ # If the facility has representative outfall status, is it properly documented by the Division? ❑ ❑ N ❑ # Has the facility evaluated all illicit(non stormwater) discharges? ❑ 0 ❑ ❑ Comment: See summary for details. Page 3 of 3