HomeMy WebLinkAboutWQ0032515_BIMS Report_20240628Compliance Inspection Report
Permit:WQ0032515 Effective:12/01/21 Expiration:01/31/28 Owner :City of Durham
SOC:
Contact Person:
Region:
County:
Directions to Facility:
Durham
Raleigh
Brian Merritt
Effective:Expiration:Facility:North Durham WRF
1900 E Club Blvd
Durham NC 27704
Title:Phone:919-560-4384
Get on I-440W. Take US-70W to E Club Blvd in Oak Grove. Take exit 179 from I-85N/US15N. Sharp L onto E Club Blvd.
Secondary ORC(s):
Phone:Certification:Primary ORC:
SINC,WWNC,System Classifications:
On-Site Representative(s):
Related Permits:
WQ0003504 City of Durham - City of Durham Class B Residuals Program
NC0023841 City of Durham - North Durham WRF
Secondary Inspector(s):
Primary Inspector:
Inspection Date:Exit Time:Entry Time:
Phone:
06/25/2024 09:15AM 10:30AM
Chris Smith 919-791-4257
Facility Status:
Permit Inspection Type:
Reason for Inspection:Inspection Type:
Not CompliantCompliant
Routine
Reclaimed Water
Compliance Evaluation
Question Areas:
Treatment Flow Measurement-Water
Use Records
Treatment Flow Measurement
Record Keeping
Treatment Return pumps
Treatment Disinfection
End Use-Reuse
(See attachment summary)
Page 1 of 7
Inspection Date:
Permit:
Inspection Type :
Owner - Facility:
Reason for Visit:
WQ0032515
06/25/2024 Compliance Evaluation
City of Durham
Routine
Inspection Summary:
On June 25, 2024, Chris Smith of the Raleigh Regional Office conducted a compliance evaluation inspection of the reclaimed
water generation and bulk distribution system located at the Durham Water Reclamation Facility.
This facility is permitted for operation of a reclaimed water generation and bulk distribution facility consisting of:
the installation of an on-line turbidimeter and all associated piping, valves, controls, and appurtenances and the continued
operation of reclaimed water generation from NPDES Permit No. NC0023841, two variable frequency drive (VFD) pumps to
maintain pressure to the distribution system, a 4-inch overhead loading arm, a 3-inch quick connect fitting at ground level for
distribution to customers, a sodium hypochlorite feed system with bulk tank and meter pump to supply chlorine to the pump
feed system, a manual valve at the loading station with a hand held turbidimeter (for use prior to installation of on-line
turbidimeter), flow meter, and residual chlorine monitor, a catch basin that drains to the headworks, and all associated
piping, valves, controls, and appurtenances.
The purpose of this inspection was to ensure compliance with the subject permit. During the inspection, the cooperation and
assistance provided by Brian Merritt and Jason Cash was helpful and appreciated.
This compliance evaluation inspection consisted of the following:
•Review of the permit
•Review of the owner/facility information
•Review of ORC logbooks, calibration documentation, Non-Discharge Monitoring Reports (NDMR) and
•On-site inspection of treatment components
The current permit was effective December 1, 2021 and expires on January 31, 2028.
The inspector reviewed the facilities Operation and Maintenance Plan, which was found to be adequate. The flowmeter used
by the facility is a factory calibrated Seimens magmeter and cannot be field calibrated. The handheld turbidimeter calibration
records were not available during the inspection. Brian Merritt stated during the inspection that he will provide calibration
documentation as soon as possible. The facility is certified to monitor and collect two field parameters’ values (chlorine and
turbidity) in house. A calibration log is maintained for the chlorimeter, but residual chlorine values are not a parameter that is
required to be reported by the permit. Chlorine content is monitored by a SCADA connected monitor and maintained around
1ppm. Sodium Hypochlorite is added to the reclaimed water pump by quill at delivery as the UV disinfection system for the
NPDES discharge is after the reclaimed water pumps.
Residuals are managed under NPDES permit NC0023841.
Reclaimed water is distributed to the reclaimed system by two (2) pumps and is used on site for equipment washing, seal
water, odor control, firefighting (if necessary). The facility has not distributed any reclaimed water from the bulk distribution
station in over a year. A Seimens magmeter is installed near the bulk loading station to track distribution. Turbidity and
chlorine are recorded as water is pumped to customer tanks.
Operation and Maintenance documents are maintained on the facility computer system and a printed copy was available
during the inspection. All reclaimed water users and customers receive training from facility staff prior to receiving reclaimed
water. Reclaimed water system components are properly color coded.
Overall, the facility appears to be well-maintained and operated and in compliance with permit conditions.
Note: The facility permit requires continuous turbidity monitoring once reclaimed water begins to be sent to the Mist Lake
facility listed as PPI-003 in Attachment A in the permit. Until that time, the facility should continue to monitor turbidity when
it is bulk distributed to customers using the above-mentioned hand-held turbidimeter. Additionally, until such time that any
Page 2 of 7
Inspection Date:
Permit:
Inspection Type :
Owner - Facility:
Reason for Visit:
WQ0032515
06/25/2024 Compliance Evaluation
City of Durham
Routine
reclaimed water is distributed from the bulk filling station or to the Mist Lake facility, and as long as all generated reclaimed
water continues to be used solely within the facility and returned to the treatment system, the facility may submit monthly
Non-Discharge Monitoring Reports (NDMRs) indicating “No Flow” on the forms.
Page 3 of 7
Inspection Date:
Permit:
Inspection Type :
Owner - Facility:
Reason for Visit:
WQ0032515
06/25/2024 Compliance Evaluation
City of Durham
Routine
Type Yes No NA NE
Infiltration System
Lagoon Spray, LR
Activated Sludge Spray, LR
Single Family Spray, LR
Activated Sludge Drip, LR
Activated Sludge Spray, HR
Recycle/Reuse
Single Family Drip
Reuse (Quality)
Yes No NA NETreatment Flow Measurement-Effluent
Is flowmeter calibrated annually?
Is flowmeter operating properly?
Does flowmeter monitor continuously?
Does flowmeter record flow?
Does flowmeter appear to monitor accurately?
Comment:
Treatment Return pumps Yes No NA NE
Are they in place?
Are they operational?
Comment:
Treatment Disinfection Yes No NA NE
Is the system working?
Page 4 of 7
Inspection Date:
Permit:
Inspection Type :
Owner - Facility:
Reason for Visit:
WQ0032515
06/25/2024 Compliance Evaluation
City of Durham
Routine
Do the fecal coliform results indicate proper disinfection?
Is there adequate detention time (>=30 minutes)?
Is the system properly maintained?
If gas, does the cylinder storage appear safe?
Is the fan in the chlorine feed room and storage area operable?
Is the chlorinator accessible?
If tablets, are tablets present?
Are the tablets the proper size and type?
Is contact chamber free of sludge, solids, and growth?
If UV, are extra UV bulbs available?
If UV, is the UV intensity adequate?
# Is it a dual feed system?
Does the Stationary Source have more than 2500 lbs of Chlorine (CAS No. 7782-50-5)?
If yes, then is there a Risk Management Plan on site?
If yes, then what is the EPA twelve digit ID Number? (1000-____-____)
If yes, then when was the RMP last updated?
Comment:
Record Keeping Yes No NA NE
Is a copy of current permit available?
Are monitoring reports present: NDMR?
NDAR?
Are flow rates less than of permitted flow?
Are flow rates less than of permitted flow?
Are application rates adhered to?
Is GW monitoring being conducted, if required (GW-59s submitted)?
Are all samples analyzed for all required parameters?
Are there any 2L GW quality violations?
Is GW-59A certification form completed for facility?
Is effluent sampled for same parameters as GW?
Do effluent concentrations exceed GW standards?
Are annual soil reports available?
# Are PAN records required?
# Did last soil report indicate a need for lime?
If so, has it been applied?
Are operational logs present?
Are lab sheets available for review?
Page 5 of 7
Inspection Date:
Permit:
Inspection Type :
Owner - Facility:
Reason for Visit:
WQ0032515
06/25/2024 Compliance Evaluation
City of Durham
Routine
Do lab sheets support data reported on NDMR?
Do lab sheets support data reported on GW-59s?
Are Operational and Maintenance records present?
Were Operational and Maintenance records complete?
Has permittee been free of public complaints in last 12 months?
Is a copy of the SOC readily available?
No treatment units bypassed since last inspection?
Comment: