HomeMy WebLinkAboutNCG550166_Compliance Evaluation Inspection_20171003 ROY COOPER
aov or
• MICHAEL S. REGAN
Samitary
WaterResourc s S.JAY ZIMMERMAN
ENitIRQNMENTAL QUAt,YTY /.?tf £ r
•
October 3, 2017
Kimberly A. Woods
R' CEIVED/NCDEQ/DwR
1080 Baker Crossroads Rd OCT Y 0
Reidsville, NC 27320 2017
Water Quality
SUBJECT: Compliance Evaluation Inspection Report Permitting Section
Certificate of Coverage NCG550166 under NPDES General Permit NCG550000
Facility Located at 1080 Baker Crossroads Rd, Rockingham County
Dear.Ms. Woods:
On September 28, 2017, Paul DiMatteo of the Division of Water Resources ("Division"), Winston-Salem
Regional Office conducted a Compliance Evaluation Inspection of the above referenced wastewater treatment
system.The Division is required to inspect these types of systems at least every 5 years. An inspection
summary follows and an inspection report is attached for your records.
Site Review
The system consists of a septic tank, subsurface sand filter, chlorinator, and outfall, with final disposal
to an unnamed tributary to the Rock House Creek. No sewage malfunction was observed at or around the
septic tank. The chlorinator was not located during the inspection.There appeared to be a slight discharge of
water from the outfall.
Please note that annual effluent monitoring is required as stated in Part LA of the Permit.The
chlorinator should also be checked weekly to ensure an adequate supply of chlorine disinfection tablets.
Tablets should only be used if they are labeled for wastewater disinfection; do not use tablets that are labeled
for pool disinfection.
Documentation & Monitoring Review
A review of documentation was not conducted at the time of inspection.We would like to remind you
to conduct and document the following:
- Effluent monitoring must be performed as required in the permit.
- All system components must be maintained at all times and in good working order.
- Inspect the septic tank and secondary tanks at least yearly to determine if solids must be removed.
- Pump the septic tank every 5 years, or when the solids level is found to be more than 1/3 of the
liquid depth in any compartment, whichever is greater. All tanks should be emptied of their
contents whenever any of the tanks meet this requirement.
- Contents removed from septic tanks shall be disposed of at a location and in a manner compliant
State of North Carolina I Environmental Quality I Water Resources
450 West Hanes Mill Road,Suite 300,Winston-Salem,NC 27105
336-776-9800
F
with all local and state regulations.
- Inspect the outfall location at least twice per year to ensure that no visible solids or other obvious
evidence of system malfunctioning is observed. .
- Inspect the tablet chlorinator (if applicable) at least weekly to ensure there is an adequate supply
•
of tablets for continuous & proper operation.Tablets used for chlorination must be labeled for
wastewater use.
- Any monitoring data obtained shall be retained onsite for a minimum of 5 years.
- Additional requirements as stated in NCG550000.
There were no significant issues noted during the inspection; therefore, a response to this report is not
required.
Thank you for your cooperation in this matter. If you should have any questions, please do not hesitate
to contact Paul DiMatteo at 336-776-9691 or our office at 336-776-9800.
Sincerely,
y%der" -
77 Sher IV. Knight, P.E., Regio Supervisor
• Water Quality Regional Operations Section
Winston-Salem Regional Office
Division of Water Resources, NCDEQ
Enclosures—Inspection Report and Summary
Cc: WQS Winston-Salem Regional Office
NSDE—SiElt iti.fi1F7'Nlail;-Se-rvic& eater-
State of North Carolina I Environmental Quality I Water Resources
450 West Hanes Mill Road,Suite 300,Winston-Salem,NC 27105
336-776-9800
United States Environmental Protection Agency
Form Approved.
EPA Washington,D.C.20460 OMB No.2040-0057 •
Water Compliance Inspection Report Approval expires 8-31-98
Section A:National Data System Coding(i.e.,PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1 u 2 3 I NCG550166 111 12I 17/09/28 117 18 19I c I 20Li
21I 1 1 1 I I I I- I I I I I I I I I I 1 1 1 1 1 1 1 l l l l l I�I I I I I I I I I i I 166
Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA — Reserved
671 I 70 LJ L I 71 I liI 72 I L�,J I 73 I I 174 75� l
I I I I I I 180
Section B:Facility Data
Name and Location of Facility Inspected(For Industrial Users discharging to POTW,also include Entry Time/Date Permit Effective Date
POTW name and NPDES permit Number) 10:15AM 17/09/28 09/06/15
1080 Baker Crossroads Rd
1080 Baker Cross Rd Exit Time/Date Permit Expiration Date
Reidsville NC 27320 10:30AM 17/09/28 12/07/31
Name(s)of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data
///
Name,Address of Responsible Official/Title/Phone and Fax Number
Contacted
Charles R Benton,1080 Baker Cross Rd Reidsville NC 27320///
, No
• Section C:Areas Evaluated During Inspection(Check only those areas evaluated)
Permit IIII Operations&Maintenance Facility Site Review IN Effluent/Receiving Waters
Section D:Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s)and Signature(s)of Inspector(s) Agency/Office/Phone and Fax Numbers Date
Paul DiMatteo WSRO WQ//336-776-9691/
e ,0447
Signature of anagement Q A Reviewer Agency/Office/Phone and Fax Numbers Date
l V.1 1' /P/ —iP/
EPA Form 3560-3(Rev 9-94)Previous edition are solete.
Page# 1
NPDES yr/mo/day Inspection Type (Cont.) 1
31 NCG550166 111 121 17/09/28- 17. 18 I,. •
Section D:Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary)
Site Review
The system consists of a septic tank, subsurface sand filter, chlorinator, and outfall,with final
disposal to an unnamed tributary to the Rock House Creek. No sewage malfunction was observed at
or around the septic tank.The chlorinator was not located during the inspection.There appeared to be
a slight discharge of water from the outfall.
Please note that annual effluent monitoring is required as stated in Part I.A of the Permit.The
chlorinator should also be checked weekly to ensure an adequate supply of chlorine disinfection
tablets.Tablets should only be used if they are indicated for wastewater disinfection.
Documentation & Monitoring Review
A review of documentation was not conducted at the time of inspection.We would like to remind
you to conduct and document the following:
- Effluent monitoring must be performed as required in the permit.
- All system components must be maintained at all times and in good working order.
- Inspect the septic tank and secondary tanks at least yearly to determine if solids must be removed.
- Pump the septic tank every 5 years, or when the solids level is found to be more than 1/3 of the
liquid depth in any compartment,whichever is greater.All tanks should be emptied of their contents
whenever any of the tanks meet this requirement.
Contents removed from septic tanks shall be disposed of at a location and in a manner
compliant with all local and state regulations.
- Inspect the outfall location at least twice per year to ensure that no visible solids or other obvious
evidence of system malfunctioning is observed.
- Inspect the tablet chlorinator(if applicable)at least weekly to ensure there is an adequate supply of
tablets for continuous &proper operation.Tablets used for chlorination must be labeled for wastewater
use.
- Any monitoring data obtained shall be retained onsite for a minimum of 5 years.
- Additional requirements as stated in NCG550000.
Page# 2
•
Permit: NCG550166 Owner-Facility: 1080 Baker Crossroads Rd
- . . •Inspection Date: 09/28/2617 - Inspection Type:_ Compliance Evaluation - - •-- ---
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? • ❑ ❑ ❑
Does the facility analyze process control parameters,for ex:MLSS,MCRT,Settleable ❑ ❑ • ❑
Solids,pH,DO,Sludge Judge,and other that are applicable?
Comment:
Permit Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ • ❑
application?
Is the facility as described in the permit? • ❑ ❑ ❑
#Are there any.special conditions for the permit? ❑ • ❑ ❑
Is access to the plant site restricted to the general public? • ❑ ❑ ❑
Is the inspector granted access to all areas for inspection? • ❑ ❑ ❑
Comment:
Effluent Pipe Yes No NA NE
Is right of way to the outfall properly maintained? • ❑ ❑ ❑
Are the receiving water free of foam other than trace amounts and other debris? ❑ ❑ ❑
If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ MI ❑
Comment: There was evidence of a slight discharge at the outfall.