Loading...
HomeMy WebLinkAbout20070776 Ver 3_More Info Letter_20080903OF W A T? Michael F. Easley, Governor Q G William G. Ross Jr., Secretary ` Cq Y North Carolina Department of Environment and Natural Resources ^i O Coleen Sullins, Director Division of Water Quality September 3, 2008 DWQ Project # 07-0776 Haywood County CERTIFIED MAIL: RETURN RECEIPT REQUESTED Waynesville Commons Retail Associates, LLC 1765 Meriman Road Akron, OH 44313 Subject Property: Waynesville Town Center Richland Creek [040305, 5-16-(1), B, TR] REQUEST FOR MORE INFORMATION: STORMWATER MANAGEMENT PLAN Dear Sir or Madam: On October 22, 2007, the Division of Water Quality (DWQ) issued a 401 Water Quality Certification to impact 52 linear feet of perennial stream to construct the Waynesville Town Center in Haywood County. In order to meet Condition 9 of the 401 Certification for this project, a stormwater management plan for Outparcel B, dated July 31, 2008. was received by the DWQ on August 1, 2008. The DWQ has detennined that your stormwater management plan was incomplete as discussed below. Please provide the following information so that we may continue to review your project. Additional Information Requested: Overall site: a. Clearly show the stormwater drainage system, showing inlets, pipes and pipe outlets. b. Infiltration trenches and wet detention ponds are NOT preferred devices to use on a Brownfield site. Please consider the use of a more suitable device, such as a closed sand filter or a lined bioretention area. DWQ will only allow the use of a wet detention pond or an infiltration trench on this site if you can demonstrate that there is no practical alternative and if you can satisfactorily address all of the following concerns. 2. Wet detention pond: a. The vegetated shelf of the wet detention pond must extend around the entire perimeter of the main treatment area. Retaining walls may then be placed upslope of the vegetated shelf. b. The pond does not have enough capacity to treat the water quality volume for the one-inch storm in this drainage area (5,032 cubic feet). c. Please show the calculation of average depth. It appears that the average depth is significantly less than three feet, which will affect the SA/DA ratio. d. Please provide the detail for the orifice structure and show the discharge pipe. NoofthCarolina 401 Oversight/Express Review Permitting Unit Naturally 1650 Mail Service Center, Raleigh, North Carolina 27699-1650 2321 Crabtree Boulevard, Suite 250, Raleigh, North Carolina 27604 Phone: 919-733-1786 / FAX 919-733-6893 / Internet: http h'o.cnr,tatcnc us/newetland, An Equal Opportunity/Affirmative Action Employer - 50% Recycled/ 10% Post Consumer Paper Waynesville Commons Retail Associates, LLC Page 2 of 3 September 3, 2008 e. Please provide design calculations for the 15-foot retaining wall to show that it will be stable. f. Please provide data on the borings at the proposed site of the wet detention basin to show that the elevation of the SHWT elevation. The "In Situ" Constant Head Permeameter Table indicates that the depth to the water table on the day the Bio- Basin C site was tested was only 1.25 inches beneath the ground surface. Because this is a Brownfield site, the invert of the pond should be above the level of the SHWT. g. The Supplement Form indicates that the pond will be lined with PVC; however, this is not shown on the plans. Infiltration trench: a. The infiltration trench must be equipped with a high flow bypass structure. Using a level spreader to bypass high flows is not allowed. Volume in excess of the treatment volume must be evenly distributed across a minimum 30-foot wide filter strip. b. Please provide data on the borings at the proposed site of the infiltration trench to show that the SHWT elevation is at 275 1.00. The "In Situ" Constant Head Permeameter Table indicates that the depth to the water table on the day the Bio- Basin C site was tested was only 1.25 inches beneath the ground surface. c. The Supplement Form indicates that a forebay will be provided for pretreatment; however, this is not shown on the plans. d. The infiltration trench must be equipped with a minimum of one observation well. Please submit this information within 30 calendar days of the date of this letter. The DWQ will require the above additional information to finalize review of the stormwater management plan for the subject property. You are welcome to contact me at 919-715-3425 if you have questions or would like to set up a meeting. Sincerely, (3? va" C- a-,",> Annette. Lucas, Environmental Engineer III 401 Oversight/Express Review Permitting Unit AML/aml cc: Kevin Barnett, DWQ Asheville Regional Office USACE Asheville Regulatory Field Office File Copy Central Files Gary O'Nesti, Cedarwood Development, Inc., 1765 Meriman Road, Akron, OH 44313 Filename: 070776 W aynesvilleTow nCenter(Haywood)S W_Hold. doc ¦ Complete items 1, 2, and 3. Also complete A. Sign tun item 4 if Restricted Delivery is desired. ? Agent ¦ Print your name and address on the reverse X ? Addressee so that we can return the card to you. B. 71`eivel!! ( nnted Name) C. Date of Delivery ¦ Attach this card to the back of the mailpiece, or on the front if space permits. I D. Is delivery address different from item 1? ? Yes 1. Article Addressed to: If YES, enter delivery address below: ? No Waynesville-mmons Retail Associates, LLC 1765 Meriman Road Akron, OH 44313 DWQ# 07-0776-Haywood 3. S rvice Type Certified Mail Express Mail ? Registered Return Receipt for Merchandise ? Insured Mail ? C.O.D. _x 14. Restricted Delivery? (Extra Fee) ? Yes 2. Article Number (Transfer from ser 7008_130_0 0001 2224 9429 PS Form 3811, February 2004 Domestic Return Reosipt 102595-02-M-1540 UNITED STATES POSTAL Skr0F 0? :nG &E-1P, 21,0013 • Sender: Please print your name, address, and ZIP+4 in this box • NC DENR Division of Water Quality 401 Oversight/Express Unit 2321 Crabtree Boulevard, Suite 250 Raleigh, NC 27604 fillliiEl?liftill?Fitlfill?ljl?tfiltilti? ulltii?itil? a ?tf1?