Loading...
HomeMy WebLinkAboutSW5240602_Design Calculations_20240704 • neiengineering.com 303-431-7895 12600 W Colfax Avenue,Suite C500,Lakewood,CO 80215 NCDEQ Post-Construction Stormwater Permitting Group 512 N. Salisbury Street, Office 640E Raleigh, NC 27604 June 25, 2024 RE: Red Bud Solar Stormwater Management Administrative Review Kaitlin Peck, In response to your email on 6/25/24 this letter is being provided as part of the Red Bud Solar Post-Construction Stormwater Permit Application. Included with this letter is the Low Density calculation table from the NCDEQ Supplemental EZ form and a summary table of all temporary diversion swales proposed as part of this project. Please note that these swales are intended only to divert runoff to temporary sediment basins during construction and will not be retained at the end of the project when the basins are decommissioned. ``'R.`o t t i 111111,,,, .‘` -cN CARS ,,. • `•\0�.voFESs/ptiq. -9,,. SEAL ',i . /GINEE--.1— 1.16,f14 .0,Zi :::. ./iii;'gN'D.gR``�``.. 06/25/2024 Thank you for your attention in regard to this submission. Best Regards, Digitally signed by Ryan D Brick pate 202406.25 12:47:27-06'00' Ryan Brick rbrick@neieng.com 12600 W Colfax Ave, Suite C500, Lakewood CO 80215 303-431-7895 Red Bud Solar LOW DENSITY DESIGN REQUIREMENTS FOR LOW DENSITY PROJECTS FROM 02H .1003 1 Is project below density thresholds set forth in the applicable stormwater rule? Yes 2 Does project maximize dispersed flow and minimize channelization of flow? Yes 3 Has the use of piping been minimized per .1003(2)(c)? Yes 4 Side slopes of the vegetated conveyances (H:V) 3 to 1 5 Maximum velocity in the vegetated conveyances during the 10-year storm? 6 Are curb outlet swales proposed? No 7 Maximum longitudinal slope of curb outlet swale(s) (%) 8 Bottom width of curb outlet swale(s) (feet) 9 Maximum side slope of curb outlet swale(s) (H:V) 10 Minimum length of curb outlet swale(s)(feet) 11 Are treatment swales used instead of curb outlet swales? 12 Is stormwater released at the edge of the setback as dispersed flow? Yes 13 Have stormwater outlets been designed to prevent downslope erosion? Yes 14 Are variations to rule .1003 proposed? No ADDITIONAL INFORMATION - L 15 Please use this space to provide any additional information about this low density project: All ditches on site that drain to High Quality Waters are temporary and will not be retained after construction. Red Bud Temporary Diversion Ditch Summary Table Velocity Channel Shear Dimensions Diversion Flow Q V Capacity Stress Bottom Side Max Liner Material Ditch ID (cfs) Width Slope Depth (fps) (cfs) (lb/ft-) (ft) (ft/ft) (ft) _ V1, V2 1.1 2.65 2.78 0.69 ! 0.10 4.00 0.50 Straw with Net _ 1.A 1.8 4.26 18.39 1.02 3.00 3.00 0.80 Straw with Net _ 3.A 4.9 4.49 7.95 1.14 5.00 3.00 0.30 Straw with Net 5.A 6.1 4.06 6.82 0.99 3.00 3.00 0.40 Straw with Net _ 7A.A 2.9 3.85 16.62 0.83 3.00 3.00 0.80 Straw with Net _ 8.A 2.6 3.85 6.46 0.89 3.00 3.00 0.40 Straw with Net 13.A 0.4 4.94 21.33 1.37 3.00 3.00 0.80 Straw with Net 13.6 1.3 4.35 7.31 1.13 3.00 3.00 0.40 Straw with Net 19.A 1.7 4.56 7.67 1.25 3.00 3.00 0.40 Straw with Net _ 23B.A 8.7 3.82 22.60 0.72 5.00 3.00 _ 0.80 Straw with Net 26.A 2.3 3.78 6.36 0.86 3.00 3.00 0.40 Straw with Net 26.B 10.6 3.80 19.45 0.76 4.00 3.00 0.80 Straw with Net _ 27.A 9.7 4.27 11.73 1.00 4.00 3.00 0.50 Straw with Net 28.A.1 16.5 5.33 31.56 1.41 5.00 3.00 0.80 Straw with Net 28.A.2 16.5 3.00 17.76 2.50 5.00 3.00 0.80 Rock Riprap D50=9 _ 28.A.3 16.5 4.01 23.73 0.80 5.00 3.00 0.80 Straw with Net 28.B 34.5 5.27 43.85 1.24 8.00 3.00 0.80 Straw with Net 28.0 1.6 4.04 10.66 1.38 0.10 4.00 0.80 Straw with Net _ 28.D 17.2 2.55 20.36 2.58 0.10 4.00 1.40 Rock Riprap D50=9 28.E.1 7.4 3.54 18.13 0.66 4.00 3.00 0.80 Straw with Net _ 28.E.2 7.4 2.85 14.58 2.37 4.00 3.00 0.80 Rock Riprap D50=9 _ 28.E.3 7.4 2.78 _ 14.24 2.26 4.00 3.00 _ 0.80 Rock Riprap D50=9 _ 29.A 16.5 5.04 _ 25.82 1.33 4.00 3.00 _ 0.80 Straw with Net 29.B 3.7 3.77 16.28 0.80 3.00 3.00 0.80 Straw with Net 29.0 4.9 4.60 5.38 1.31 3.00 3.00 0.30 Straw with Net 30.A 2.2 3.77 16.28 0.80 3.00 3.00 0.80 Straw with Net _ 33.A 5.6 3.87 16.73 0.84 3.00 3.00 0.80 Straw with Net _ 34.A 2.4 4.83 20.88 1.31 3.00 3.00 0.80 Straw with Net 35.A 1.5 4.13 17.85 0.96 3.00 3.00 0.80 Straw with Net _ 38.A 12.1 3.66 21.67 0.67 5.00 3.00 0.80 Straw with Net 39.A 15.9 4.47 16.76 1.01 6.00 3.00 0.50 Straw with Net 40.A 3.1 4.60 7.73 1.27 3.00 3.00 0.40 Straw with Net 41.A 4.1 4.36 7.33 1.14 3.00 3.00 0.40 Straw with Net _ 43.A 3.9 3.64 6.11 0.79 3.00 3.00 0.40 Straw with Net _ 44.A 12.5 4.42 26.17 0.97 5.00 3.00 0.80 Straw with Net 48.A - BYP 4.6 4.43 10.98 1.05 5.00 3.00 0.40 Straw with Net 49.A 4.1 3.34 5.61 0.67 3.00 3.00 0.40 Straw with Net _ 52B.A 7.4 3.90 8.77 0.89 3.00 3.00 0.50 Straw with Net _ 52A.A 1.1 4.36 18.84 1.07 3.00 3.00 0.80 Straw with Net _ 56.A 0.7 4.45 3.20 1.30 3.00 3.00 0.20 Straw with Net 60.A 3.4 3.51 5.90 0.74 3.00 3.00 0.40 Straw with Net