Loading...
HomeMy WebLinkAboutNC0020389_Pretreatment Compliance Inspection Letter and Report_20240702DocuSlgn Envelope ID: 0OF57B8B-33AA-4F68-AD23-225562530340 ROY COOPER Governor ELIZABETH S. BISER S-ra tejue V RICHARD E. ROGERS, JR Ulreeme NORTH CAROLINA Environmental Quality July 2, 2024 Ms. Kimberly Pickett Town Manager Town of Benson P.O. Box 69 Benson, NC 27504 Subject: Pretreatment Compliance Inspection Benson Wastewater Treatment Plant NPDES Permit No. NCO020389 Johnston County Dear Ms. Pickett: On June 27, 2024, Donald Smith of the Division of Water Resources (DWR) - Raleigh Regional Office conducted a Pretreatment Compliance Inspection (PCI) of the program at the Town of Benson (Town). The assistance given by Mr. Brian Leavitt — Superintendent -ORC was greatly appreciated. Findings during the inspection were as follows: 1. Currently, the Town has one Significant Industrial User (SIU) — Chicopee -- Berry Global, Inc., 2. The pretreatment files of Chicopee (0001). The files needed for review were available for inspection, contained all the required elements and were in good condition and well organized. The SIU was compliant during the most recent seini-annual period (July 2023 December 2023). The Town's Pretreatment Program inspected the SIU as identified in the permit. 3. A review of the files containing the pretreatment program elements (head works analysis, industrial waste survey, enforcement response plan, short-term monitoring plan, and sewer use ordinance) was conducted. These files were available for review and well organized. All elements were up to date, with some awaiting DWR review and/or approval. A Head Works Analysis (HWA) was submitted September 25, 2020, with three subsequent revisions with the last revision on February 22, 2022. An industrial waste survey (IWS) was submitted June 20, 2024. The Town is awaiting DWR approval for the HWA and IWS. 4. Mr. Leavitt indicated that a Short -Term Monitoring Plan (STMP) was set to begin soon to prepare for one year of monitoring data before the NPDES Permit expiration (April 30, 2026). STMP data will be available with the NPDES permit renewal application. Please ensure that required minimum practical quantitation limits are used for the STMP data collection. NC PQLs can be found at https:. www.deq.nc.gov:`pgls'download?attachment 5. Fiscal Year 2023 - Pretreatment Annual Report (PAR) dated February 26, 2024, was reviewed during the inspection. The PAR included an Allocation Table (AT) based on the last DWR -� Vonh Carolina Dcpanmcnt of Lnvironnkcntal Quality j on of 1Vatcr Resources �{ D�P Raleigh Regional 011ice 1 3800 Barren Drive I Raleigh, \onh Carolina 27601) d��a\ �/ 919.791.4200 DocuSign Envelope ID OOF57B8B-33AA-4F6B-AD23-225562530340 approved HWA from September 25, 2020. Lead, Zinc, and Copper were identified in the AT as being overallocated. The AT also did not include Nickel. Please submit a revised 2023 PAR to include the most recent revision of HWA and AT that has been submitted to DWR, even if it has not been approved by DWR. The 2023 PAR also included an Industrial Data Summary Form (IDSF) that included "NIA" for all calculated SIU permitted parameters for chronic and technical review criteria (TRC) percent non-compliance. If a SIU is fully compliant with limited parameters for the semi-annual compliance judgement period, the % violations and % TRC violations would be identified by a calculated "091•0" violations. For parameters that are monitored and not limited, "N A" or "Monitor Only" should be included for % violation compliance judgement since compliance judgement is not being calculated. Include an updated IDSF with your revised 2023 PAR submittal. The Town's Pretreatment Program is satisfactory and appears to be in tune with NPDES compliance initiatives. Thank you for your continued cooperation and support of the Pretreatment Program. If you have any questions or comments, please call Donald Smith at (919) 791-4234 or donald.smith@deq.nc.gov. Sincerely, EoeuSlyned by: IU,LSSa V. ha Utt D 297flE6AB31114F Vanessa E. Manuel, Assistant Regional Supervisor Water Quality Regional Operations Section Raleigh Regional Office Division of Water Resources Enclosure: Town of Benson PCI Inspection Form Cc: Laserfiche North Carolina Department of Environmental Quality 1 Division orWater Resources 5I2 North Salisbury Street 1 1611 Mat] Smtcc Center I Raleigh, North Carohna 27699-1611 1719.707.90(H) DocuSign Envelope ID: 00F57B8B-33AA-4F6B-AD23-225562530340 NORTH CAROLINA DIVISION OF WATER RESOURCES PRETREATMENT COMPLIANCE INSPECTION (PCI) REPORT BACKGROUND INFORMATION lComplete Prior To PCI; Review Proeram Info Database Sheet(s 1. Control Authority (POTW) Name: Town of Benson 2. Control Authority Representative(s): Brian avitt 3. Title(s): SuperintendenUORC 4. Last Inspection Date: 08.18;2023 Inspection Type (Check One): ❑ PCI ® Audit S. Has Program Completed All Requirements from the Previous Inspection and Program Info Sheet(s)? ® YES ❑ NO 6. Is POTW under an Order That Includes Pretreatment Conditions? ❑ YES ® NO Order Type, Number, Parameters: ICIS CODING Main Program Permit Number N I C 1 0 1 0 1 2 1 0 1 3 1 $ 1 9 MMIDDIYY 1 05 101 1 21 1 Are Milestone Dates Being Met? ❑ YES ❑ NO 7. Current Number Of Significant Industrial Users (SIUs)? 8. Number of SiUs With No IUP, or With an Expired IUP? 9. Number of SIUs Not Inspected B POTW in the Last Calendar Year? no 10. Number of SIUs Not Sampled 8 POTW in the Last Calendar Year? 11. Number of SIUs In SNC For Limits Violations During Either of the Last 2 Semi -Annual Periods? 0 12. Number of SIUs in SNC For Reporting During Either of the Last 2 Semi -Annual Periods? 0 13. Number of SIUs in SNC with Pretreatment Schedule? 0 14. Number of SIUs on Schedules? 0 15. Current Number Of Categorical Industrial Users (CIUs)? 16. Number of CIUs in SNC? 0 POTW INTERVIEW 17. Since the Last PCI, has the POTW had any NPDES Limits Violations? If Yes, What are the Parameters and How are these Problems Being Addressed? 18. Since the Last PCI, has the POTW had any Problems Related to an Industrial Discharge (Interference, Pass -Through, Blockage, Citizens` Complaints, Increased Sludge Production, Etc.)? If Yes, How are these Problems Being Addressed? 19. Which Industries have been in SNC for Limits or Reporting during SNC for either of the Last 2 Semi -Annual Periods? Not Been Published for SNC for Public Notice?(May refer to PAR if Excessive SIUs in SNC} Not Put 20. Which Industries are on Compliance Schedules or Orders? For all SIUs on an Order, Has a Signed Copy of the Order been sent to the Division? 21. Are Any Permits or Civil Penalties Currently Under Adjudication? If Yes, Which Ones? LTMPISTMP FILE REVIEW.- ® YES NO Total Phosphorous Qtr Avg Exceedance. See comment section on how problem was addressed ❑ YES NO Limits: None Reporting: None dished: NIA None YES NO 22. Is LTMPISTMP Monitoring Being Conducted at Appropriate Locations and Frequencies? ® YES ❑ NO 23. Are Correct Detection Levels being used for all LTMPISTMP Monitoring? ® YES ❑ NO 24. Is LTMPISTMP Data Maintained in a Table or Equivalent? ® YES ❑ NO Is Table Adequate? ® YES ❑ NO 25. All LTMPISTMP effluent data reported on Discharge Monitoring Report? ® YES ❑ NO Division Inspector, please verify yourself'. 26. if NO to 23 - 26, list violations NC DWR Pretreatment Compliance Inspection (PCI) Form Updated December 2016 Page I DocuSign Envelope ID: 00F57B8B-33AA-4F68-AD23-225562530340 27. Should any Pollutants of Concern be Eliminated from or Added to LTMP'STMP? ❑ YES ® NO If yes, which ones? Eliminated: Added: 28. PRETREATMENT PROGRAM ELEMENTS REVIEW— Please review POTW files, verify POTW has copy of Program Element in their files, complete with supporting documents and copy of PERCS Approval Letter, and dates consistent with Pro gram Info: Program Element Last Submittal Date In file? Last Approval Date In file Date Next Due, If Applicable Headworks Analysis (HWA) 09125�2020 Yes No 09/24/2015 N Yes Lj No Industrial Waste Survey IWS 06(20�2024 N Yes LJ No 12/03/2018 0 Yes No Sewer Use Ordinance SUO 0410512013 0 Yes No 04/11/2013 Yes No Enforcement Response Plan (ERP) 02125/2020 0 Yes El No 1 03/17/2020 Yes No Short Term Monitoring Plan (STMP) 10131/2013 N Yes Lj No 1 01/07/2014 N Yes Lj No INDUSTRIAL USER PERMIT (IUP) FILE REVIEW (3 IUP FILE REVIEWS OR I FILE REVIEW AND I IU INSPECTION) 29. User Name 1. Chicopee (001) 2. N/A 3. NIA 30. IUP Number 0001 1 NIA NIA 31, Does File Contain Current Permit? Yes No Yes No Yes No 32. Permit Expiration Date F 12/31/2027 33. Categorical Standard Applied (I.E. 40 CFR, Etc.) Or NIA NIA 34, Does File Contain Permit Application Completed Within One Year Prior N Yes U Yes No Yes No to Permit Issue Date? !11 35 Does File Contain an Inspection Completed Within Last Calendar Year? Z Yes I INoI U Yes U No Yes Lj No 36. a_ Does the File Contain a Slug/Spill Control Plan? a. ®Yes ❑No a. ❑Yes ❑No a. ❑Yes ❑No 11 b. If No, is One Needed? (See Inspection Form from POTW) b. ❑Yes ON— b. ❑Yes ❑No b. ❑Yes ❑No 37. For 40 CFR 413 and 433 TTO Certification, Does File Contain a Toxic 0Yes0No0Nj67;;6RZNj OYes❑No❑NIA Organic Management Plan TOMP)? 38. a. Does File Contain Original Permit Review Letter from the Division? a. ❑Yes ®No a. ❑Yes ❑No a. ❑Yes ❑No b. All Issues Resolved? b 0YesMoON A_] b ❑Yes❑NoON A b.❑Yes❑No❑N A 39. During the Most Recent Semi -Annual Period, Did the POTW Complete Yes U No U Yes Lj No U Yes U No its Sampling as Required by IUP, including Flow? 40. Does File Contain POTW Sampling Chain-Of-Custod Forms? Yes NoI U Yes U Nojj UYes U No 41. During the Most Recent Semi -Annual Period, Did the SIU Complete its ®Yes❑No❑N A ❑Yes❑No❑N A ❑Yes❑No❑N A Sampling as Required b IUP, including flow? 41b. During the Most Recent Semi -Annual Period, Did SIU submit all reports ®Yes❑No❑N A ❑Yes❑No❑N A ❑Yes❑No❑N A on time? 42a. For categorical IUs with Combined Wastestream Formula (CWF), does ❑Yes❑NoON A ❑Yes❑No❑N A ❑Yes❑No❑N A file includeprocess/dilution flows as Required b IUP? 42b. For categorical IUs with Production based limits, does file include ❑Yes❑No®N A OYes❑No❑N A ❑Yes❑No❑N production rates and/or flows as Required b IUP? fl 43a. During the Most Recent Semi -Annual Period, Did the POTW Identify Z Yes U No U Yes Lj No Yes No All Limits Non -Compliance from Both POTW and SIU Sampling? 43b. During the Most Recent Semi -Annual Period, Did the POTW Identify ElYesONo❑N A ❑Yes❑No❑N A ❑Yes❑No❑N A All Reporting -Non -Compliance from SIU Sampling? 44. a. Was the POTW Notified by SIU (Within 24 Hours) of All Self- a.OYesMoON A a.❑Yes❑NOON A a.OYesONo❑N A Monitoring Violations? b. Did Industry Resample and submit results to POTW Within 30 Days? b OYcs0Not1lN A b OYesOvoON)A b DYesMoON A c. If applicable, Did POTW resample within 30 days of becoming aware of SIU limit violations in the POTW's sampling of the SIU? c.OYesONoON A c ❑YesONo❑N.A c.❑Yes❑No❑N A 46. During the Most Recent Semi -Annual Period, Was the SIU in SNC? U Yes DQ No Yes No 11 U Yes El No 47. During the Most Recent Semi -Annual Period, Was Enforcement Taken ❑Yes❑No®N A ❑Yes❑No❑N A ❑Yes❑NOON A as Specified in the POTW's ERP (NOVs, Penalties, timing, etc.)? 48, Does the File Contain Penalty Assessment Notices? ❑Yes®No❑N A ❑Yes❑NO❑N.A ❑Yes❑No❑N A 49. Does The File Contain Proof Of Penalty Collection? ❑Yes❑No®N A ❑Yes❑No❑N A 11 ❑Yes❑No❑N A 50. a. Does the File Contain Any Current Enforcement Orders? a.DYesONoON A 11 a.❑YesMo❑N A 11 a.pvesONoON A NC DWR Pretreatment Compliance Inspection (PC1) Fonn Updated December 2016 Page 2 DocuSign Envelope ID; 0OF57B8B-33AA-4F66-AD23-225562530340 b. Is SIU in Compliance with Order? _ 51. Did the POTW Representative Have Difficulty in Obtaining Any of This Requested Inforination For You? b OYesONo0h.A b OYes❑No❑V A b OY.0NoON A Yes ED No LJ Yes Lj No Lj Yes Ll No FILE REVIEW COMMENTS: Total phosphorus quarterly average exceedance in September 2023, according to the ORC it was a result of switching chlorine disinfection carry water from well to county water. County water contains orthophosphate as a corrosion inhibitor. Switched carry stater back from county water to well water and have not had any additional total phosphorus non-compliance. INDUSTRY INSPECTION 1CIS CODING: Main Program Permit Number MMIDDIYY I I I 1 I I I I 1 1 1 1 1 1 Industry Inspected: _ SIU inspection was not conducted during Pt'I 2. Industry Address: 3. Type of Industry/Product: _ 4. Industry Contact: Phone: Fax: Title: 5. Does the POTW Use the Division Model Inspection Form or Equivalent? ❑ YES ❑ NO 6. Did the POTW Contact Conduct the Following Parts of the Industrial Inspection Thoroughly'' Comments: A. Initial Interview ❑ YES ❑ NO B. Plant Tour ❑ YES ❑ NO C. Pretreatment Tour ❑ YES ❑ NO D. Sampling Review ❑ YES [:]NO E. Exit Interview ❑ YES ❑ NO Industrial Inspection Comments: OVERALL SUMMARY AND COMMENTS: Comments: Pretreatment Program appears satisfactory and in tune with NPDES compliance initiatives Requirements: Revise and resubmit 2023 PAR HWA and IDSF Recommendations: NOD: ❑ YES ® NO NOV: ❑ YES ®NO QNCR: ❑ YES ®NO POTW Rating: Satisfactory X Marginal UnSatisfactory PCl COMPLETED BY: OocuSigned by: DATE: 7 /2 / 202 4 St,4,, *24'FA647A NC DWR Pretreatment Compliance Inspection (PCI) Form Updated December 2016 Page 3