Loading...
HomeMy WebLinkAboutNCG550121_Notice of Deficiency_20170713 (2) II(WeA)' /2(C)- &A,eb/2-- RECEIVED SOC PRIORITY PROJECT: Yes No X If Yes, SOC No. NOV 1 8 1992 To: Permits and Engineering Unit Water Quality Section TECHNICAL SUPPORT BRANCH Attention: Mack Wiggins Date: November 17 , 1992 NPDES STAFF REPORT AND RECOMMENDATION County: Gaston Permit No. NC0045632 PART I - GENERAL INFORMATION 1 . Facility and Address : Deese Residence Post Office Box 189 Kelly Farm Road Mount Holly, North Carolina 28120 2 . Date of Investigation: 11-16-92 3 . Report Prepared By: G. T. Chen 4 . Persons Contacted and Telephone Number: Mr. Don C . Deese, Property Owner; ( 704 ) 827-8259 5 . Directions to Site : From the intersection of Kelly/West Land Farm Road ( SR 1924 ) and Lane Road (SR 2085 ) in west Mount Holly, travel west on SR 1924 approximately 0 . 6 mile. Deese residence is the fourth house past the Green Meadows Golf Course, on the left (south) side of the road. 6 . Discharge Point(s ) . List for all discharge points : Latitude: 35° 19 ' 20" Longitude: 81° 03 ' 56" Attach a U. S .G. S . map extract and indicate treatment facility site and discharge point on map. USGS Quad No. : F 14 SE USGS Name: Mount Holly, NC 7 . Site size and expansion are consistent with application? Yes X No If No, explain: 8 . Topography (relationship to flood plain included) : Uniformly sloping toward receiving water at the rate of 3 to 5% . The treatment facilities are subsurface and could be affected by infiltration during wet seasons . 9 . Location of nearest dwelling: One dwelling within 100 feet of the discharge point. 10 . Receiving stream or affected surface waters : Unnamed tributary to Taylors Creek a. Classification: C b. River Basin and Subbasin No. : Catawba and 03-08-33 c. Describe receiving stream features and pertinent downstream uses : The receiving water is a narrow and shallow drainage ditch which enters Taylors Creek via a private pond in the Green Meadows Golf Course. Down- stream users are not known. PART II - DESCRIPTION OF DISCHARGE AND TREATMENT WORKS 1 . a. Volume of wastewater to be permitted: 0 . 00045 MGD (Ultimate Design Capacity) b. What is the current permitted capacity of the wastewater treatment facility? 0 . 00045 MGD c . Actual treatment capacity of the current facility (current design capacity) ? 0 . 00045 MGD d. Date(s) and construction activities allowed by previous Authorizations to Construct issued in the previous two years : N/A e. Please provide a description of existing or substantially constructed wastewater treatment facilities : The existing facility consists of a 1, 000 gallon septic tank, 1125 square feet of nitrification field, a subsurface sand filter and tablet chlorination. f. Please provide a description of proposed wastewater treatment facilities : N/A g. Possible toxic impacts to surface waters : N/A h. Pretreatment Program (POTWs only) : N/A in development: approved: should be required: not needed: 2 . Residuals handling and utilization/disposal scheme: a. If residuals are being land applied, please specify DEM permit no. : Residuals Contractor: NPDES Permit Staff Report Version 10/92 Page 2 Telephone No. : b. Residuals stabilization: PSRP: RFRP: Other: c. Landfill : d. Other disposal/utilization scheme (specify) : Sludge is removed by Cline Septic Tank Service and taken to a municipal wastewater treatment facility for final disposal . 3 . Treatment plant classification (attach completed rating sheet) : Single Family Dwelling, no rating. 4 . SIC Code(s) : 4952 Wastewater Code(s) of actual wastewater, not particular facilities, i .e. , non-contact cooling water discharge from a metal plating company would be 14, not 56 . Primary: 04 Secondary: Main Treatment Unit Code: 44007 PART III - OTHER PERTINENT INFORMATION 1 . Is this facility being constructed with Construction Grant Funds or are any public monies involved (municipals only) ? N/A 2 . Special monitoring or limitations (including toxicity) requests : N/A 3 . Important SOC, JOC or Compliance Schedule dates : (please indicate) N/A Date Submission of Plans and Specifications Begin Construction Complete Construction 4 . Alternative Analysis Evaluation: Has the facility evaluated all of the non-discharge options available. Please provide regional perspective for each option evaluated. Spray Irrigation: Insufficient land area for spray irrigation. NPDES Permit Staff Report Version 10/92 Page 3 a• Connection to Regional Sewer System: If and when area-wide sewer system becomes available. Subsurface: Existing facility was converted from a subsurface disposal system. Other Disposal Options : N/A 5 . Other Special Items : N/A PART IV - EVALUATION AND RECOMMENDATIONS It is recommended that the NPDES Permit for this facility be renewed. ,r5W Signature of Report Preparer Water Quality gional Supervisor //Date NPDES Permit Staff Report Version 10/92 Page 4 �� II . - .# #: MODEL SUmMARi UATA *#*: DISCHARGER 1 DONNIE DEESE SFR SUBBASIN 030533 RECEIVING STREAM UT TAYLORS CREEK STREAM CLASS : C 7010 0 .0 CFS WINTER 7010 : CFS DESIGN TEMPERATURE: 25 DEGREES C . WASTEFLOW : 0 . 00045 McD ILENGTHISLOPE I VELOCITY ! DEPTH I K1 I Kr 1 Kn 1 K2 I Oro 1 IMILES IFT/MI I FPS 1 FT I /DAY I /DAY 1 /DAY I /DAY ICFS/MII I I 1 I I I I I I 1 SEGMENT 1 I 0 . 101210.501 0 . 10 10 . 09 I :1 . 26 11 . 26 1 0 . 00 142 . 25 10 . 00 I REACH 1 I I I I I I I I 1 I ALL RATES ARE AT 25 DEGREES C . :.* k INPUT DATA SUMMARY *4 k I FLOW I CBOD I NBOD I D .O . I ! CFS I MG/L I MG/L I MG/ L I ! I I I I SEGMENT 1 REACH 1 I I I I I WASTE I 0 . 00 1110 . 00 I 0 .00 I 6.00 I HEADWATERS ' 0 .00 I 0 .00 I 0 . 00 I 0 . 00 I TRIBUTARY I 0. 00 I 0 . 00 I 0 .00 I 0 .00 I RUNOFF * I 0 .00 1 0 . 00 1 0 . 00 1 0 .00 I _ - RUNOFF FLOW IS IN CFS/MILE - -1-- ________ -_—_-- 1 i