Loading...
HomeMy WebLinkAboutNCG550121_Compliance Evaluation Inspection_20150522 46 LAVA NCDENR North Carolina Department of Environment and Natural Resources Pat McCrory Donald R. van der Vaart Governor Secretary May 22,2015 RECEIVED Mr. John Grounds MAY 2 6 2015 1011 Kelly Road Mount Holly,North Carolina 28120 CENTRAL FILES y DWR SECTION Subject: Compliance Evaluation Inspection Grounds Single Family Residence COC#NCG550121 Gaston County Dear Mr. Grounds: Enclosed is a copy of the Compliance Evaluation Inspection report(CEI)for the inspection conducted at the subject facility on May 20, 2015 by Mr. Barry Love with this Office. Thank you for your assistance and cooperation during the inspection. The report should be self-explanatory. Please take special note of the comments sections for things which need to be addressed. Pool chlorine tablets were being used. These are harmful to aquatic life and only tablets approved for wastewater use should be used(calcium hypochlorite). Please provide documentation to this office when you have purchased new tablets. No analytical results were available at the time of the inspection. The permit requires annual monitoring of the system. Please provide a copy of the analytical results when available. The septic tank should be pumped every five years or as needed. If you have any questions,comments, or need assistance with understanding any aspect of your permit or this report,please do not hesitate to contact me at(704)-663-1699. Sincerely, Barry Love,Environmental Specialist Mooresville Regional Office Water Quality Regional Operations Section Division of Water Resources,NCDENR Cc: MRO SFR-Grounds Central Files Mooresville Regional Office,610 East Center Avenue,Suite 301,Mooresville,NC 28115 Phone:704-663-1699\Internet:www.ncwaterquality.org An Equal Opportunity\Affirmative Action Employer-Made in part by recycled paper • United States Environmental Protection Agency Form Approved. E PA Washington,D.0 20460 OMB No.2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A:National Data System Coding(i.e.,PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 ��, 2 IS I 3 I NCG550121 111 12 I 15/05/20 117 18 I I 19 I 201 21I I I I I I I I I I II r6 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ------- Reserved--------- 67I I 70I LJ) 71 I it I 72 I N 1 73I I I74 75I I I I I I I 180 Section B:Facility—Data l Name and Location of Facility Inspected(For Industrial Users discharging to POTW,also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 12:00PM 15/05/20 13/08/01 1011 Kelly Road 1011 Kelly Rd Exit Time/Date Permit Expiration Date 12:35PM 15/05/20 18/07/31 Mount Holly NC 28120 Name(s)of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data /// Name,Address of Responsible Official/Title/Phone and Fax Number Contacted Linda Grounds,1011 Kelly Rd Mount Holly NC 28120/// No Section C:Areas Evaluated During Inspection(Check only those areas evaluated) Permit Operations&Maintenance 1. Records/Reports IN Facility Site Review Ni Effluent/Receiving Waters In Laboratory Section D:Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s)and Signature(s)of Inspector(s) Agency/Office/Phone and Fax Numbers Date Barry F Love MRO WQ//704-663-1699 Ext.263/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3(Rev 9-94)Previous editions are obsolete. Page# 1 NPDES yr/mo/day Inspection Type 1 31 NCG550121 111 121 15/05/20 11 7 18 I C • Section D:Summary of Finding/Comments(Attach additional sheetsof narrative and checklists as necessary) Page# 2 f Permit: NCG550121 Owner-Facility: 1011 Kelly Road Inspection Date: 05/20/2015 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? • 0 ❑ ❑ Does the facility analyze process control parameters,for ex: MLSS, MCRT, Settleable ❑ ❑ • ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: No analytical data was available. The permittee needs to have analysis of the wastewater done to be in compliance with the permit requirements. Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ 0 • ❑ application? Is the facility as described in the permit? ❑ ❑ ❑ • #Are there any special conditions for the permit? 01100 Is access to the plant site restricted to the general public? ❑ ❑ 11 ❑ Is the inspector granted access to all areas for inspection? 11 ❑ ❑ ❑ Comment: Septic Tank Yes No NA NE (If pumps are used)Is an audible and visual alarm operational? ❑ ❑ • ❑ Is septic tank pumped on a schedule? ❑ ❑ ❑ 11 Are pumps or syphons operating properly? ❑ ❑ 11 ❑ Are high and low water alarms operating properly? ❑ ❑ • ❑ Comment: The septic tank was last pumped on 5/13/2010 according to an invoice in the file. The permit requires that the septic tank be pumped every 5 years,so it is due again. Sand Filters (Low rate) Yes No NA NE (If pumps are used)Is an audible and visible alarm Present and operational? ❑ ❑ 11 ❑ Is the distribution box level and watertight? ❑ ❑ ❑ • Is sand filter free of ponding? • ❑ ❑ ❑ Is the sand filter effluent re-circulated at a valid ratio? ❑ ❑ ❑ 111 #Is the sand filter surface free of algae or excessive vegetation? MEI ❑ ❑ #Is the sand filter effluent re-circulated at a valid ratio?(Approximately 3 to 1) ❑ ❑ ❑ • Comment: The sand filter is underground. Disinfection-Tablet Yes No NA NE Are tablet chlorinators operational? 11 ❑ ❑ ❑ Are the tablets the proper size and type? ❑ • 0 ❑ Page# 3 i Permit: NCG550121 Owner-Facility: 1011 Kelly Road Inspection Date: 05/20/2015 Inspection Type: Compliance Evaluation Disinfection-Tablet Yes No NA NE Number of tubes in use? 2 Is the level of chlorine residual acceptable? ❑ ❑ ❑ • Is the contact chamber free of growth, or sludge buildup? ❑ ❑ ❑ Is there chlorine residual prior to de-chlorination? ❑ ❑ ❑ III Comment: Pool tablets were being used. The permittee was advised that these were unacceptable as they are harmful to aquatic life. Only tablets approved for wastewater use should be used (calcium hypochlorite). Page# 4