Loading...
HomeMy WebLinkAboutNC0024201_Historical information (Including performance report)_20210202Roanoke Rapids Sanitary District January 27, 2021 NC Dept of Environmental Quality FEB 0 2 2021 Raleigh Regional Office Re: Dear Mr. Vinson: R. Enclosures Co: hAnpdes pennilV2O_sy s performance aim report Itr.doc.x Mr. Scott Vinson, Regional Supervisor Water Quality Regional Operations Section Raleigh Regional Office Division of Water Resources, NCDEQ 1628 Mail Service Center Raleigh, N. C. 27699-1628 Enclosed please find three (3) copies of Roanoke Rapids Sanitary District's System Performance Annual Report for calendar year 2020. This report is submitted to meet the requirements of the NCDEQ policy to promote public oversight of system performance for reduction and elimination of sanitary sewer overflows (SSO’s) from wastewater collection or treatment works. If these documents should be provided to additional DWQ personnel; or if additional information is required, please contact me. Very truly yours, Roanoke Rapids Sanitary District Steven Ellis David Scott File CERTIFIED MAIL 7005 3110 0001 6339 2067 RETURN RECEIP F REQUESTED 2020 System Performance Annual Report Collection System #WQC00027 NPDES #NC0024201 NCG110000 P.O. Box 308 1000 Jackson Street Roanoke Rapids, NC 27870 (252)537-9137 Fax: (252)537-3064 vwnv.rrsd.org Page: 1/1 leley Brown. P.E. Chief Executive Officer JY 2020 Annual Performance Report Roanoke River Waste Treatment Plant NC0024201 & Collection System WQCS00027 Abstract The Annual Performance Report provides key performance information that demonstrates the POTW's accountability to ensure Roanoke Rapids Sanitary District's stewardship and prosperity by addressing its environmental, operations, and maintenance challenges through transformative process and technology solutions. Steven L. Ellis, David Scott sellis@rrsd.org dscott@rrsd.org sw General Information:I. C. Person in charge/contact D. Applicable Permit(s) Page 1 Roanoke Rapids Sanitary District 2020 Annual Performance Report National Pollution Discharge Elimination System (NPDES): NC0024201 Land Application (L.A.): WQ0001989 Stormwater (General): NCG110000 2. WWTP: Steven L Ellis, Operator in Responsible Charge (ORC) Timothy Skipper, Back-up ORC Roanoke River Wastewater Treatment Plant 135 Aqueduct Road Weldon, NC 27890 Phone: 252-536-4884 A. Regulated entity: Roanoke Rapids Sanitary District, Collection Systems (C.S.) and Wastewater Treatment Plant (WWTP), together Publicly Owned Treatment Works (POTW) B. Responsible entity: Roanoke Rapids Sanitary District, Dan Brown, CEO PO Box 308 Roanoke Rapids, NC 27870 Phone: 252-537-9137 2. WWTP: E. Description of C.S.: The collection system consists of approximately 146 miles of sewer lines and six lift stations that serve Roanoke Rapids, Gaston, and portions of Halifax and Northampton Counties, which serves an approximate population of 17,600. The sewer lines within Roanoke Rapids, Gaston and all sub­ divisions, which connect to two main Interceptors, range in size from 8" to 12". There are two main 30" diameter Interceptors transporting wastewater to the WWTP. 1. C.S.: North Carolina Environmental Management Commission System-wide Wastewater Collection System Permit No. WQCS00027 1. C.S.: David Warren Scott, Operator in Responsible Charge (ORC) Eric Wes Deaton, Back-up ORC Roanoke Rapids Sanitary District, Distribution & Collection 425 East 11th St. Roanoke Rapids, NC 27870 Phone: 252-537-9747 Page 2 Roanoke Rapids Sanitary District 2020 Annual Performance Report Treatment processes at the wastewater plant include grit and rag removal. This is followed by primary clarification, trickling filter BOD buffering, biological secondary treatment, activated solids treatment, secondary clarification, final effluent chlorination/de-chlorination processes, and final pH adjustment. The system has six sewer lift stations. Three stations are in the Gaston basin. HWY 46 Pump Station serves a Northampton County School. The Old Emporia Road Pump Station serves the Chowan Housing Projects and the Hwy 48 Pump Station pumps all flows from Gaston and Northampton County via an 8" force main suspended from the NC HWY 48 Bridge spanning the Roanoke River to the Roanoke River Interceptor. The remaining three pump stations are located within Roanoke Rapids basins and serve residential and some light commercial customers. Two of the stations, Belmont and Poplar Springs, discharge to the Roanoke River Interceptor while the Greenbriar Pump Station discharges to the Chockoyotte Creek Interceptor. The Chockoyotte Creek Interceptor serves the south side of the Sanitary District and three sub­ divisions located outside the Roanoke Rapids city limits: Lake View Park, Greenbriar, and Lincoln Heights. The Interceptor begins adjacent to 1100 Zoo Road. There is one primary basin pump station along the route. The interceptor pipe sizes range from 12" to 30". The Roanoke River Interceptor collects wastewater from basins located on the north side of the Sanitary District. The Gaston basin and Northampton County are also served by this interceptor. The Interceptor begins just west of 100 Gaston Road (NC HWY 48) in Roanoke Rapids. There are 3 primary basin pump stations and 2 secondary pump stations served by the interceptor whose pipe sizes range from 18" to 30". F. Description of WWTP: The wastewater treatment plant is rated at 8.34 million gallons per day (MGD). Peak flow is rated at 12.5 MGD. During these processes, solids are removed from two locations. Primary clarification removes settleable solids from incoming wastewater to an anaerobic digestion unit. Here, the solids in the absence of oxygen receive pH adjustment, mixing, and heating to produce a stabilized material suitable for land application. Once the solids are stable, excess water is decanted and returned to the plant for further treatment. The stabilized, thickened solids are treated with lime for odor control and then removed to a holding tank prior to transportation for land application. Secondary clarification removes solids from the activated solids process. Here, solids in the presence of oxygen, pH control, and mixing, accumulate in excess. They are removed, chemically stabilized, and added to a holding facility. All stabilized solids are analyzed, and land applied according to their nutrient value, ceiling limit (mg/kg) and accumulative requirements. Performance:II. 1. C.S: 2. WWTP: Page 3 Roanoke Rapids Sanitary District 2020 Annual Performance Report The District contracted with USDA wildlife services for outfall cutting, stream debris removal and beaver management from Chockoyotte Creek located adjacent to its interceptor. This ongoing work improved access to the interceptor and helped minimize flooding of manholes along the easement. Over the course of 2020, the Roanoke River Wastewater Plant operated very efficiently. There were no permit violations or monitoring and reporting violations. The plant flows ranged from a daily maximum of 12.4 MGD to a minimum of 2.0 MGD. The average daily flow was 3.6 MGD. The plant treated 1,507,500,000 gallons of wastewater throughout the year, which was discharged to the Roanoke River. During 2020, there were two plant bypasses of treatment units in which 1,536,877 gallons of Wastewater with some biological treatment were bypassed to the Roanoke River. There were five times during the year when flows into the plant were increased due to heavy rains. During these times, flow was equalized to the equalization basins to lower peak flows through the plant. Throughout 2020, 7,360,300 gallons of wastewater was equalized and later returned to the plant for treatment. The efforts to repair the collection system and reduce Inflow and Infiltration from There are two pumping stations distributing wastewater into and through the plant. They are the Influent Pump Station, which includes an equalization pump, and the Trickling Filter Effluent Pump Station. The Influent Pump Station has the capacity to pump 20 MGD, the equalization pump 6 MGD and the Trickling Filter Effluent Pump Station 27 MGD. Standing by in conjunction with these two pump stations is the Emergency Flood Pump Station with a capacity of 21 MGD to remove treated effluent from the plant during high river stages which prevent normal gravity flow discharge. Also, a storm water pump station has been installed. This station intercepts site runoff, an unnecessary treatment load and potential site flooding condition, and removes it before entry to the plant. It has the capacity to pump 11.5 MGD. Numerous other pumps and mixers are located throughout the plant to facilitate process control. The performance of the system in 2020 was particularly good. There were no permit violations or monitoring and reporting violations. The District's Fat, Oil, and Grease (FOG) Program performed 29 inspections of area restaurants and food preparation facilities (FSE). Full facility inspections were limited due to the ongoing COVID-19 pandemic. There were no notices of violation. All FSE were advised to continue following "Best Management Practices" and maintain maintenance records. The District FOG program is continuing our public education program. There were no Sanitary Sewer Overflows (SSO) out of twenty-seven total SSOs during the period attributed to FOG in 2020. PARAMETER A. Permit limit violation Page 4 Roanoke Rapids Sanitary District 2020 Annual Performance Report The wastewater treatment plant also relies heavily on electricity to operate all its treatment units. The Sanitary District entered a contract with Greggory Poole Caterpillar for the purchase and installation of a new full load generator. The new generator will be installed in early 2021 and will be complimentary to the existing full load generator to provide redundant emergency back-up power. During 2020, the Land Application Permit was renewed to facilitate land application of stabilized biosolids. A total of 1,535.15 applicable acres is permitted; a decrease of 450.31 acres from the prior permit. There were 2,275,042 gallons, or 430.27 dry tons of biosolids applied to 327.17 acres. There were no permit violations for the land application program in 2020. The following table illustrates the treatment performance of the wastewater plant and its ability to meet and comply with the NPDES permit requirements: prior years continued in 2020. This work has led to lower peak flows for shorter durations and reduced the number of bypasses from the plant as illustrated in the following table: _______________Year Max Day (MGD) Avg. Daily Flow - MGD Estimated I & I - MGD Annual Rainfall - in. REQUIRED REMOVAL 85% 85% N/A N/A N/A N/A 2017 2.96 1.06 41.33 ANNUAL REMOVAL 95.6% 92.0% N/A N/A N/A N/A 2018 9.0 3.34 1.54 60.5 2019 11.4 1.48 46 2020 12.4 3.58 1.86 66.3 2016 17.3 3.62 1.76 49.99 The Wastewater Treatment Plant relies on anaerobic digesters for primary sludge stabilization. In 2019 digester number 1 original sludge heater installed in 1965 for was replaced. The new heater is safer and more efficient. In 2020, the parts to update the heater for digester number 3 were installed to make both heaters alike. Furthermore, a new waste gas burner was installed that will automatically control the methane gas system pressure for the digester heaters. This will prevent the wasting and release of unburned methane gas into the atmosphere. CBQD TSS Fecal Coliform NH3-N Total-N Total-P MONTHLY LIMIT 25mg/L 30mg/L 200 Colonies N/A N/A N/A WEEKLY LIMIT 37.5mg/L 45mg/L 400 Colonies N/A N/A N/A ANNUAL AVERAGE 7.7mg/L 15.4mg/L 35 Colonies <1.9mg/L <15.3mg/L 0.99mg /L DAILY MAX 35.6mg/L 109.3mg/L >240 Colonies 8.2mg/L 32.3mg/L 1.80mg/L DAILY MIN 3.0mg/L 4.4mg/L 1 Colony <0.5mg/L 4.8mg/L 0.47mg/L 1. C.S.: None 2. WWTP: None B. Monitoring and Reporting Violations C. 2020 Sanitary Sewer Overflows 2. WWTP: N/A Page 5 Roanoke Rapids Sanitary District 2020 Annual Performance Report There was an estimated total of 360,575 gallons spilled in SSO's in 2020. These spills are the result of capacity exceedance due to wet weather conditions. This correlates to 18.49 spills per 100 miles of pipe. 1. C.S.: There were 27 reportable SSO's in 2020. 1. Manhole K-419 near Chockoyotte Creek & Smith Church Rd. 1/4/2020 200 Gal. 2. Manhole B-46 3rd & Starke Dr. on 1/14/2020 675 Gal. 3. Manhole B-46 3rd & Starke Dr. on 2/7/2020 5,100 Gal. 4. Manhole B-52 3rd & Rapids St. on 2/7/2020 900 Gal. 5. Manhole C-41 1st & Franklin St. on 2/7/2020 300 Gal. 6. Manhole A-54 on Land St. on 2/7/2020 13,500 Gal. 7. Manhole B-46 on 3rd & Starke Dr. 6/17/2020 8,400 Gal. 8. Manhole MGB-10 on Gail Dr. 6/18/2020 600 Gal. 9. Manhole A-54 on Land St. 8/4/2020 1,050 Gal. 10. Manhole A-54 on Land St. 9/17/2020 16,200 Gal. 11. Manhole B-46 on 3rd & Starke Dr. 9/18/2020 4,050 Gal. 12. Manhole B-l on Harris St. on 9/29/2020 3,300 Gal. 13. Manhole B-46 on #rd & Starke St. 9/29/2020 3,300 Gal. 14. Manhole B-46 on 3rd & Starke Dr. on 11/12/2020 15,750 Gal. 15. Manhole B-52 3rd & Rapids St. on 11/12/2020 10,500 Gal. 16. Manhole A-54 on Land St. on 11/12/2020 27,000 Gal. 17. Manhole C-12 on 2nd & Franklin St. 9,900 Gal. 18. Manhole C-11A on 2nd & Franklin St. 9,900 Gal. 19. Manhole C-13B on 1st & Franklin St. 15,600 Gal. 20. Manhole G-46 on River Rd. on 11/12/2020 46,500 Gal. 21. Manhole C-188 in WestRock Paper on 11/12/2020 600 Gal. 22. Manhole D-228 in WestRock Paper on 11/12/2020 9,000 Gal. 23. Manhole C-183 in WestRock Paper on 11/12/2020 16,200 Gal. 24. Manhole C-186 in WestRock Paper on 11/12/2020 15,750 Gal. 25. Manhole C-184 in WestRock Paper on 11/12/2020 52,500 Gal. 26. Manhole C-185 in WestRock Paper on 11/12/2020 63,000 Gal. 27. Manhole J-46 on Ivey St. on 11/17/2020 5,400 Gal. 1. C.S.: None 2. WWTP: None D. Bypass of Treatment Facility E. Description of any known environmental impact or violations. Description of corrective measures taken to address violations or deficiencies.F. District employees cleaned 22.81 miles of sewer lines and CCTV'd all suspect problem areas. Page 6 The District contracted with Tri-State Utilities to clean and CCTV the Chockoyotte Creek Interceptor from Zoo Rd. to Roanoke Ave. Tri-State cleaned and TV'd 7,700 feet of 12" sewer main in Basin J. District employees completed 17 total new replacement taps in 2020. All 17 were 4" service lateral replacement taps throughout the district service area. District employees completed three Sanitary Sewer Point Repairs in 2020. The locations 1008 W 2nd St, 105 Beechwood St, and 2500 W 10th St. The District contracted with Freese and Nichols, Inc. to perform Sub-Basin 'A' sanitary sewer evaluation using flow meters and modeling with a total cost of $116,895.00. Additionally, the 1. C.S.: N/A 2. WWTP: There were two bypasses at the Wastewater Treatment Plant in 2020. 1. C.S.: Along with the wildlife control, FOG program and outfall clearing discussed above, RRSD continues to perform preventative sewer backup maintenance by cleaning with Jetter and Root Cutter; which is attached to the Jetter hose, followed by Closed Circuit TV (CCTV) camera to inspect the lines after cleaning. The District also uses its Vac-con Truck, which cleans the line more effectively and proves to be more reliable than the old unit. The District also continues to use the Rausch CCTV van purchased in 2018 extensively. District employees utilized the District's excavator mounted flail mower in conjunction with NC Wildlife Solutions LLC to cut and clear 19.01 miles of interceptor right-of-way's and cross­ country lines in 2020. RRSD entered into Task Authorization 3 associated with its Master Agreement with Freese and Nichols to perform Wastewater Sub-Basin 'K' Sanitary Sewer Evaluation Survey (SSES) to assist RRSD in identifying areas within the sub-basin where inflow & infiltration (l/l) is occurring. Sub-Basin 'K' contains mostly 8" and 10" gravity collection lines with a 30" main interceptor (Chockoyotte Outfall) that serves the basin. The sub-basin contains approximately 435 manholes, and approximately 100,000 feet of gravity pipe. Work includes flow monitoring; manhole inspections and gravity pipe zoom camera inspection. Roanoke Rapids Sanitary District 2020 Annual Performance Report 1. C.S.: None 2. WWTP: None III. IV. Page 7 Roanoke Rapids Sanitary District 2020 Annual Performance Report 2. WWTP: All repairs to minimize the Inflow & Infiltration due to heavy rains are being made to correct known system deficiencies. The District entered into a design services agreement with Freese and Nichols, Inc. to replace a segment of 8" main during 2021 which crosses Chockoyotte Creek in the vicinity of Smith Church Road and is known to be a significant source of inflow due to the deteriorated condition of the pipe. study includes a desktop analysis of the existing system, development of existing sanitary sewer flows, review of previous study information, and hydraulic modeling to evaluate capacity in these areas. The study is expected to be completed during 2021. Notification: This System Annual Performance Report will be noted on the monthly bill and available to customers via the Roanoke Rapids Sanitary District's Webpage at www.rrsd.org . Certification: I certify, under penalty of law, that this document is complete and accurate to the best of my knowledge. I further certify that this report has been made available to the users of the named system and those users have been notified of its availability. MlI * R. Danieley Brown/PE Chief Executive Officer t April 22, 2021 SUBJECT: Dear Permittee: Limit Exceedance Violation(s): Parameter Date 001 Effluent 2/20/2021 45 48.16 Monthly Average Exceeded2/28/2021001 Effluent 30 30.6 r^DEQ A review of the February 2021 Discharge Monitoring Report (DMR) for the subject facility revealed the violation(s) indicated below: Remedial actions, if not already implemented, should be taken to correct any noted problems. The Division of Water Resources may pursue enforcement actions for this and any additional violations. If the violations are of a continuing nature, not related to operation and/or maintenance problems, and you anticipate remedial construction activities, then you may wish to consider applying for a Special Order by Consent (SOC). Sample Location Limit Value Certified Mail # 7017 2680 0000 2237 4540 Return Receipt Requested R. Danieley Brown, CEO PE Roanoke Rapids Sanitary District PO Box 308 Roanoke Rapids, NC 27870 K'.'i COOi'ER DK DELU GAI II S O/’MEI. Sf.’ JH NOTICE OF VIOLATION Tracking Number: NOV-2021-LV-0270 Permit No. NC0024201 Roanoke River WWTP Halifax County Solids, Total Suspended - Concentration (CO530) Solids, Total Suspended - Concentration (CO530) J' Reported Value Type of Violation Weekly Average Exceeded Jr Sincerely, Cc: ^DEQ WQS Raleigh Regional Office - Enforcement File Laserfiche If you have any questions concerning this matter or to apply for an SOC, please contact Cheng Zhang of the Raleigh Regional Office at 919-791-4200. x------DocuSigned by: Uwaz-SSa Auiw-d, ------B2916E6AB32144F... Vanessa E. Manuel, Assistant Regional Supervisor Water Quality Regional Operations Section Raleigh Regional Office Division of Water Resources, NCDEQ '•iq it<c- ■fi LO L USE 'Street and )■ Clty.'S'taie.'. PS Form 3811, July 2015 PSN 7530-02-000-9053 Domestic Return Receipt For delivery information, visit pur website at www.usps.com®. - PS Form 3800, April 2015 PSN 753002-000-9047 See Reverse for Instruction! COMPLETE THIS SECTION ON DELIVERYSENDER: COMPLETE THIS SECTION I a s____ $____ $____ $____ Postmark Here R. DANIELEY BROWN, CEO PE ROANOKE RAPIDS SANITARY DISTRICT PO BOX 308 ROANOKE RAPIDS, NC 27870 NOV-2021-EV-0270: NC0024201: ROANOKE RIVER WWTP HALIFAX COUNTY: NOV 04/22/2021: MAILED: 04/23/2021: ZHANG rR O cO JI ru Signature Confirmation Restricted Delivery n Article Number (Transfer from service label) ,01? ObflO 0000 203? M5M0 3. Service Type Adult Signature Adblt Signature Restricted Delivery H'Certified Mail® Certified Mail Restrioted Delivery Collect on Delivery rn ru HJ CERTIFIED MAIL® RECEIPT 'omestiCMaiJOnly ■11111111111111111 iiiiii iiiiiiiii inn 9590 9402 3415 7227 6617 45 ■ Complete items 1,2, and 3. ■ Print your name and address on the reverse so that we can return the card to you. ■ Attach this card to the back of the mailpiece, or on the front if space permits.___________ 1. Article Addressed to: Agent Addresser C. Date of Deliver R. DANIELEY BROWN, CEO PE ROANOKE RAPIDS SANITARY DISTRICT PO BOX 308 ROANOKE RAPIDS, NC 27870 NOV-2021-LV-0270: NC0024201: ROANOKE RIVER WWTP HALIFAX COUNTY: NOV 04/22/2021: MAILED: 04/23/2021: ZHANG Priority Mail Express® Registered Mail™ Registered Mail Restrict, Delivery K>Return Receipt for , , Merchandise Collect on Delivery Restricted Delivery Signature Confirmation11 r' Insured Mail Insured Mail Restricted Delivery (over $500) B. Received by (Printed Npme) D. is delivery address different from item 1? Yes If YES, enter delivery address below: No O F Fl G I A Certified Mail Fee $______________________ Extra Services & Fees (check box, add fee as appropdate) O Raturn Receipt (hardcopy) Return Receipt (electronic) Certified Mall Restricted Delivery Adult Signature Required r~| Adult Signature Restricted Delivery $ Postage $____ Total Postaj $____ Sent To ■WO =1402 341S 7227 LL17 4S • Sender: Please print your name, address, and ZIP+4® in this box* Oept of Enviroj menial APR ?8 ii'l United States Postal Service ■ A receipt (Uris portion of tire Certified Mail label). ■ A unique identifier for your mailpiece. ■ Electronic verification of delivery or attempted delivery. ■ A record of delivery (including lire recipient's signature) that is retained by the Postal Service"" for a specified period. Important Reminders: ■ You may purchase Certified Mail service with First-Class Mail*, First Class Package Service®, or Priority Mail* service. ■ Certified Mail service is not available for internalional mail. ■ Insurance coverage Is not available for purchase with Certified Mail service. However, the purchase of Certified Mail service does not change the insurance coverage automatically included with certain Priority Mail items. ■ For an additional fee, and with a proper endorsement on the mailpiece, you may request the following services: - Return receipt service, which provides a record of delivery (including the recipient's signature). You can request a hardcopy return receipt or an electronic version. For a hardcopy return receipt, complete PS Form 3811, Domestic Return Receipt; attach PS Form 3811 to your mailpiece; for an electronic return receipt, see a retail associate for assistance. To receive a duplicate return receipt for no additional fee, present this USPSO-postmarked Certified Mail receipt to th retail associate. - Restricted delivery service, which provides delivery to the addressee specified by name, or to tire addressee's authorized agent. - Adult signature service, which requires the signee to be at least 21 years of age (not available at retail). - Adult signature restricted delivery service, whic requires ttie signee to be at least 21 years of a< and provides delivery to the addressee specifie by name, or to the addressee's auUiorized ager (not available at retail). ■ To ensure that your Certified Mall receipt is accepted as legal proof of mailing, it should bear DSPS postmark. If you would like a postmark on this Certified Mail receipt, please present your Certified Mail item at a Post Office"" for postmarking. If you don't need a postmark on this Certified Mail receipt, detach the barcoded portioi of this label, affix it to the mailpiece, apply appropriate postage, and deposit the mailpiece. First-Class Mail Postage & Fees Paid USPS Permit No. G-10 USPS TRACKING# Raleigh Rcgio ial Office IMPORTANT: Save this receipt for your records. PS Form 3800, April 2015 (Reverse) PSN 7530-02-000-9047 NCDEQ DIVISION OF WATER QUALITY REGIONAL OFFICE 3800 BARRETT DRIVE RALEIGH, NC 27609