Loading...
HomeMy WebLinkAboutWQ0013555_Permit (Issuance)_20240620DocuSign Envelope ID: E9B204C2-3E2A-4925-8AF7-A8B9EE1C8ED1 ROY COOPER Governor ELIZABETH BISER Secretary •`t RICHARD E. ROGERS, JR. NORTH CARCLINA en Orvnmerdal Quorrty Director June 20, 2024 Jeff Theberge, Engineering Manager CFPUA Sent via email to: sewer.permits@cfpua.orR Subject: Permit No. WQ0013555 MODIFICATION CFPUA Motts Creek Outfall & Pump Station Wastewater Collection System Extension New Hanover County Dear Mr. Theberge: In accordance with your application received April 22, 2024, and additional information received June 7, 2024, we are forwarding herewith Permit No. WQ0013555 dated June 20, 2024 to the CFPUA (Permittee) for the construction only of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, shall void Permit No. WQ0013555 issued April 1, 2022, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. This modification is removing previously permitted infrastructure due to a project redesign in order for certification. In addition to this, approximately 1,040 LF of 20-inch and 2,160 LF of 24-inch DRY -force main is being constructed in relation to the pump station 69 expansion project. Please pay particular attention to the following conditions contained within this permit: Special Conditions: Condition 1.1: Pursuant to the request from McKim and Creed, dated February 7, 2011, and supporting pump manufacturer documentation, an alternative to the Minimum Design Criteria is granted to allow the pump station cycle time of greater than eight (8) cycles/hour. [15A NCAC 02T .0105(n)] Condition 1.2: Each pump station shall be clearly and conspicuously posted using a weatherproof sign with the address, a pump station identifying name/number, 24-Hour Emergency telephone number, and name of the owner/operator of the sewer system/pump station and instructions to call the number in the event of alarm activation or other emergency. Simplex pump stations or vacuum sewer pits serving a single-family residence may have a placard or sticker without the address placed on the control panel in lieu of a sign. [15A NCAC 02T .0305(h)(2)] Division of Water Resources —Wilmington Regional Office 127 Cardinal Drive Extension, Wilmington, North Carolina 28405 Phone: 910-796-7215\ Internet: www.deg.nc.gov DocuSign Envelope ID: E9B204C2-3E2A-4925-8AF7-A8B9EE1C8ED1 Condition 1.3: This permit shall be for the construction of the wastewater collection facilities only. No flow shall be made tributary to the subject facilities until a permit modification application is submitted (with the appropriate fee), a modified permit is issued, and the Engineer's Certification is received and approved by the Division. Only lots that can obtain a septic disposal system via the County health department may be developed until such time that the permit is modified and system permitted herein is placed into operation. [15A NCAC 02T.0116] Standard Conditions: Condition ILL This permit shall not be automatically transferable; a request must be made and approved. Condition 11.4: Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Condition 11.7: Upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form with checklist attached to this permit shall be submitted with the required supporting documents to the address provided on the form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations, or the Minimum Design Criteria. [15A NCAC 02T.01161 Condition 11.13: If the Permittee/Applicant holds a system -side collection system operation, maintenance and management permit (WQCS-prefix) from the Division, then the following applies: For all newly constructed, modified and rehabilitated pump stations, all equipment and components shall be sealed within a corrosion -resistant coating or encasement to the extent practicable and equivalent to the minimum design criteria unless the permittee can demonstrate it is not practicable or another form of corrosion resistance is employed. [15A NCAC 02T .0108 (b)] It shall be responsibility of the Permittee to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. Permit No. WQ0013555 June 20, 2024 Page 2 of 12 DocuSign Envelope ID: E9B204C2-3E2A-4925-8AF7-A8B9EE1C8ED1 If you need additional information concerning this matter, please contact Tyler Benson at (910) 796-7215 or via e-mail at tyler.bensonkdeq.nc..00vv. Sincerely, DocuSigned by: 10- --m"M On, 7F141E73B6F3456... Tom Tharrington, Assistant Regional Supervisor Water Quality Regional Operations Section Wilmington Regional Office Division of Water Resources, NCDEQ Cc: Sean Kenyon, McKim and Creed Jacob VandenBosch, Black & Veatch (Laserfiche info via email) Upload to Laserfiche Permit No. WQ0013555 June 20, 2024 Page 3 of 12 DocuSign Envelope ID: E9B204C2-3E2A-4925-8AF7-A8B9EE1C8ED1 NOR IH �:AgO_IN.4 Envrrortmrrtruf Quality In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the CFPUA NEW HANOVER COUNTY for the construction only of approximately 1,040 linear feet of 20-inch and 2,160 linear feet of 24-inch DRY -force main to serve planned future development as part of the Motts Creek Pump Station Replacement project with no additional discharge of collected wastewater into the CFPUA's existing sewerage system, pursuant to the application received April 12, 2024, and additional information received June 7, 2024, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting data subsequently filed and approved by the Department of Environmental Quality and considered a part of this permit. April 1, 2022 MODIFICATION Version 1.3 (modified June 20, 2024 per request) For the continued construction and operation upon certification of approximately 50 linear feet of 12_ inr;h, 17 lanea;feet of 24-;nchi , 33 lonea;feetaf atl , and -54 65 linear feet of 36-inch gravity sewer; a 4,260—gallon per minute pump station (firm capacity of 6.13 MGD) utilizing three of four pumps, in -line grinder, odor control system, on -site audible and visual high water alarms, telemetry, and a permanent generator with automatic transfer switch as well as approximately 76 linear feet of 12-inch, 286 linear feet of 16-inch, and 122 linear feet of 20-inch force main to serve the existing sewer basin as part of the Motts Creek Pump Station Replacement project with no additional discharge of collected wastewater into the CFPUA's existing sewerage system, pursuant to the application received March 1, 2022 and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting data subsequently filed and approved by the Department of Environmental Quality and considered a part of this permit. January 8, 2013 MODIFICATION Version 1.2 For the continued operation of a sewer system extension consisting of the abandonment of approximately 14,226 linear feet of existing 12-inch force main and an increase in the firm capacity to the existing Motts Creek Pump Station from 1,800 GPM to 3,343 GPM operating up to three (3) of four (4) 1,465-GPM pumps in parallel (utilizing approximately 15,800 linear feet of 20-inch force main permitted under Permit No. WQ0033328 and approximately 4,220 linear feet of existing 18-inch force main permitted under Permit No. WQ0002632) along with approximately 60 linear feet of new 20-inch force main; the pump station is equipped with on -site audible & visual alarms, screening, odor control, an on -site emergency backup generator, and monitored by a SCADA system with no additional discharge of collected wastewater pursuant to the permit application received on October 19, 2010 and permit issued June 1, 2011 then subsequently modified on January 8, 2013 pursuant to the application received on November 26, 2012. Permit No. WQ0013555 June 20, 2024 Page 4 of 12 DocuSign Envelope ID: E9B204C2-3E2A-4925-8AF7-A8B9EE1C8ED1 g� sruT', i o;;,a:�' NORTH �:AgO_IN.4 Envrrortmcrtruf Quality June 1, 2011 MODIFICATION Version 1.1 For the continued operation of a sewer system improvement via the abandonment of approximately 14,226 linear feet of existing 12-inch force main that results in a capacity increase of the existing Motts Creek Pump Station from 1,800 GPM to 2,930 GPM including four (4) 1,465 GPM pumps (utilizing approximately 15,800 linear feet of 20-inch force main permitted under Permit No. WQ0033328 and approximately 4,220 linear feet of existing 18-inch force main permitted under Permit No. WQ0002632) using existing odor control facilities, manual bar and automatic screening, and an on -site emergency back-up generator with approximately 60 linear feet of 20-inch force main as a part of the Motts Pump Station project with no additional discharge of collected wastewater pursuant to the permit application received on October 19, 2010. April 17, 1997 ORIGINAL ISSUANCE Version 1.0 For the continued operation of approximately 7,684 linear feet of 24 inch gravity sewer Outfall, a 1200 GPM pump station with duplex pumps, telemetry monitoring system, odor control facilities, bar and automatic screens, pre - oxidation pit, on site emergency generator, high water alarms, flow meter system, air bubbler system, and approximately 14,226 linear feet of 12-inch force main (with 203 linear feet of 14-inch force main if the approved plans alternate stream crossing is used) connecting to the existing Barnards Creek 18-inch force main to serve the New Hanover County Water & Sewer District Motts Creek Area, as an outfall collector (for several existing and proposed collection systems), and the discharge of no new wastewater flows (total design flow of pump station is 750,000 GPD) of collected domestic, commercial and industrial wastewater into the New Hanover County Water and Sewer District's existing sewerage system, pursuant to the application received March 7, 1997. This permit shall be effective from the date of issuance until rescinded and shall be subject to the specified conditions and limitations contained therein. Permit Number: WQ0013555 Issued Today: June 20, 2024 DocuSigned by: l o4K -T aN rl On, 7F141E73B6F3456... Tom Tharrington, Assistant Regional Supervisor Wilmington Regional Office Water Quality Regional Operations Section Division of Water Resources, NCDEQ By Authority of the Director and The Environmental Management Commission Permit No. WQ0013555 June 20, 2024 Page 5 of 12 DocuSign Envelope ID: E9B204C2-3E2A-4925-8AF7-A8B9EE1C8ED1 SUPPLEMENT TO PERMIT COVER SHEET CFPUA is hereby authorized to: Construct, and then operate upon certification the aforementioned wastewater collection extension. The sewage and wastewater collected by this system shall be treated in the Wilmington Southside Wastewater Treatment Facility in accordance with Permit Number NC0023973. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 15A NCAC 2T; the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as - constructed project meets the appropriate design criteria and rules. Construction and operation is contingent upon compliance with the Standard Conditions and any Special Conditions identified below. I. SPECIAL CONDITIONS Pursuant to the request from McKim and Creed, dated February 7, 2011, and supporting pump manufacturer documentation, an alternative to the Minimum Design Criteria is granted to allow the pump station cycle time of greater than eight (8) cycles/hour. [15A NCAC 02T .0105(n)] 2. Each pump station shall be clearly and conspicuously posted using a weatherproof sign with the address, a pump station identifying name/number, 24-Hour Emergency telephone number, and name of the owner/operator of the sewer system/pump station and instructions to call the number in the event of alarm activation or other emergency. Simplex pump stations or vacuum sewer pits serving a single-family residence may have a placard or sticker without the address placed on the control panel in lieu of a sign. [15A NCAC 02T .0305(h)(2)] 3. This permit shall be for the construction of the wastewater collection facilities only. No flow shall be made tributary to the subject facilities until a permit modification application is submitted (with the appropriate fee), a modified permit is issued, and the Engineer's Certification is received and approved by the Division. Only lots that can obtain a septic disposal system via the County health department may be developed until such time that the permit is modified and system permitted herein is placed into operation. [15A NCAC 02T.0116] II. STANDARD CONDITIONS 1. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. [15A NCAC 02T.0104; G.S 143-215.1(d3)] Permit No. WQ0013555 June 20, 2024 Page 6 of 12 DocuSign Envelope ID: E9B204C2-3E2A-4925-8AF7-A8B9EE1C8ED1 2. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials unless specifically mentioned herein. [15A NCAC 02T.0110] 3. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. [15A NCAC 02T .0110] 4. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met: [15A NCAC 02T .0108(b)] a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six -months and inspections are documented. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. h. A Grease Control Program is in place as follows: For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems. 2. For privately owned collection systems, the Grease Control Program shall include at least bi- annual distribution of grease education materials to users of the collection system by the permittee or its representative. Grease education materials shall be distributed more often than required in Parts (1) and (2) of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows. Right-of-ways and easements shall be maintained in the full easement width for personnel and equipment accessibility. Documentation shall be kept for Subparagraphs (a) through (i) of this Rule for a minimum of three years with exception of the map, which shall be maintained for the life of the system. Permit No. WQ0013555 June 20, 2024 Page 7 of 12 DocuSign Envelope ID: E9B204C2-3E2A-4925-8AF7-A8B9EE1C8ED1 5. Noncompliance Notification: The Permittee shall report by telephone to a water resources staff member at the Wilmington Regional Office, telephone number (910) 796-7215, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any SSO and/or spill over 1,000 gallons; or c. Any SSO and/or spill, regardless of volume, that reaches surface water Voice mail messages or faxed information is permissible, but this shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing and submitting Part I of Form CS-SSO (or the most current Division approved form) within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Part 11 of Form CS-SSO (orthe most current Division approved form) can also be completed to show that the SSO was beyond control. [G.S. 143-215.1C(a1)] 6. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. [15A NCAC 02T.0108(b)] 7. Upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form with checklist attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. If the permit is issued to a private entity with an Operational Agreement, then a copy of the Articles of Incorporation, Declarations/Covenants/Restrictions, and Bylaws that have been appropriately filed with the applicable County's Register of Deeds office shall be submitted with the certification. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Supporting documentation shall include the following: a. One copy of the project construction record drawings (plan & profile views of sewer lines & force mains) of the wastewater collection system extension. Final record drawings should be clear on the plans or in accepted electronic format and are defined as the design drawings that are marked up or annotated with after construction information and show required buffers, separation distances, material changes, etc. b. One copy of the supporting applicable design calculations including pipe and pump sizing, velocity, pump cycle times, and level control settings, pump station buoyancy, wet well storage, surge protection, detention time in the wet well, and force main, ability to flush low points in force mains with a pump cycle, and downstream sewer capacity analysis. If a portable power source or pump is dedicated to multiple stations, an evaluation of all the pump stations' storage capacities Permit No. WQ0013555 June 20, 2024 Page 8 of 12 DocuSign Envelope ID: E9B204C2-3E2A-4925-8AF7-A8B9EE1C8ED1 and the rotation schedule of the portable power source or pump, include travel timeframes, shall be provided. c. Changes to the project that do not result in non-compliance with this permit, regulations, or the Minimum Design Criteria should be clearly identified on the record drawings, on the certification in the space provided, or in written summary form. Prior to Certification (Final or Partial): Permit modifications are required for any changes resulting in non-compliance with this permit (including pipe length changes of 10% or greater by type & size, increased flow, pump station design capacity design increases of 5% or greater, and increases in the number/type of connections), regulations, or the Minimum Design Criteria. Requested modifications or variances to the Minimum Design Criteria will be reviewed on a case -by -case basis and each on its own merit. Please note that variances to the Minimum Design Criteria should be requested and approved during the permitting process prior to construction. After -construction requests are discouraged by the Division and may not be approved, thus requiring replacement or repair prior to certification & activation. [15A NCAC 02T .0116] 8. Gravity sewers installed greaterthan ten percent below the minimum required slope perthe Division's Gravity Sewer Minimum Design Criteria shall not be acceptable and shall not be certified until corrected. If there is an unforeseen obstacle in the field where all viable solutions have been examined, a slope variance can be requested from the Division with firm supporting documentation. This shall be done through a permit modification with fee. Such variance requests will be evaluated on a case -by -case basis. Resolution of such request shall be evident prior to completing and submitting the construction certification. [ 15A NCAC 02T.0105(n)] 9. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. [15A NCAC 02T .0116] 10. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. [15A NCAC 02T .0104; 15A NCAC 02T .0108(b-c)] 11. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. [15A NCAC 02T .0110; 15A NCAC 02T .0108(b)] 12. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by the Division any other Federal, State, or Local government agencies which have jurisdiction or obtaining other permits which may be required by the Division or any other Federal, State, of Local government agencies. [G.S. 143-215.1(b)] 13. If the Permittee/Applicant holds a system -side collection system operation, maintenance and management permit (WQCS-prefix) from the Division, then the following applies: For all newly constructed, modified and rehabilitated pump stations, all equipment and components shall be sealed within a corrosion -resistant coating or encasement to the extent practicable and equivalent to the Permit No. WQ0013555 June 20, 2024 Page 9 of 12 DocuSign Envelope ID: E9B204C2-3E2A-4925-8AF7-A8B9EE1C8ED1 minimum design criteria unless the permittee can demonstrate it is not practicable or another form of corrosion resistance is employed. [15A NCAC 02T .0108 (b)] Permit No. WQ0013555 June 20, 2024 Page 10 of 12 DocuSign Envelope ID: E9B204C2-3E2A-4925-8AF7-A8B9EE1C8ED1 FAST TRACK SEWER ENGINEERING CERTIFICATION PERMITTEE: CFPUA PERMIT #: WQ0013555 PROJECT: Motts Creek Pump Station Replacement (Version 1.3) ISSUE DATE: June 20, 2024 COUNTY: New Hanover This project shall not be considered complete nor allowed to operate in accordance with Condition 7 of this permit until the Division has received this Certification and all required supporting documentation. Consequently, it should be submitted in a manner that documents the Division's receipt. Send the required documentation to the Wilmington Regional Supervisor, Water Quality Section at the address at the bottom. The Permittee is responsible for tracking all partial certifications up until a final certification is received. Certifications shall include Phase/Section covered, line size & lengths installed, and listing of lots/connections to be served and pump station design, if applicable. A Final Certification shall be a complete set of record drawings and design calculations regardless of whether partials have been submitted. PERMITTEE'S CERTIFICATION I, the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof. Printed Name, Title Signature Date ENGINEERS CERTIFICATION I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to (❑ periodically, ❑ weekly, ❑ full time) observe the construction of the project name and location as referenced above for the above Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the following construction: of approximately 50finea;- feet of 12-inc-h, 17 linear- feet of , 33 fineciF feet of 30-inc,114, G ,d51 65 linear feet of 36-inch gravity sewer, a 4,260—gallon per minute pump station (firm capacity of 6.13 MGD) utilizing three of four pumps, in -line grinder, odor control system, on -site audible and visual high water alarms, telemetry, and a permanent generator with automatic transfer switch as well as approximately 76 linear feet of 12-inch. 286 linear feet of 16-inch. and 122 linear feet of 20-inch force main; such that the construction was observed to be built in compliance of this permit; 15A NCAC 2T; the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's Seal w/signature & date ❑ Final ❑ Partial (include description) Certification Comments/Qualifiers (attach if necessary): NC DWR — Water Quality Regional Operations Section 127 Cardinal Drive Extension Wilmington, NC 28405 Wilmington Regional Office Phone: 910-796-7215 FAX: 910-350-2004 DocuSign Envelope ID: E9B204C2-3E2A-4925-8AF7-A8B9EE1C8ED1 SEWER ENGINEERING CERTIFICATION CHECKLIST To be completed by the certifying engineer prior to operation of the permitted sewers, per 15A NCAC 02T.0116. Certifying Engineer: Certification Review Date: Project Name: W Q00 Project County: 1) Has permittee information changed since the permit was issued (or last modified): change of mailing address, change of ownership, transfer from developer to HOA/POA, etc. ❑ Yes ❑ No • If yes, please provide either a change of ownership form or new contact information. Note that transfer of permits from the developer to the HOA/POA must occur with the first certification. 2) Have the as -built drawings have been signed, sealed, and dated by an N.C. PE? ❑ Yes ❑ No 3) Final Engineering certification? ❑ Yes ❑ No • If Partial Engineering certification, provide detailed narrative including what is being certified in the current phase, what was previously certified (if applicable), and what is left to be certified. 4) Adequate information related to sewer lines: ❑ Yes ❑ No ❑ N/A • Three feet minimum cover has been provided for all sewers unless ferrous pipe was installed. • Minimum diameters for gravity sewers are 8-inches for public lines and 6-inches for private lines. • Manholes have been installed: At the end of each line, at all changes in grade, size, or alignment, at all intersections, and at distances not greater than 425 feet; minimum diameter shall be 4 feet (48-inches). 5) Adequate information related to pump stations: ❑ Yes ❑ No ❑ N/A • Ensure power reliability option was selected per 15A NCAC 02T.0305(h). 6) Was project construction completed in accordance with all of the following: ❑ Yes ❑ No ❑ N/A • 15A NCAC 02T, Minimum Design Criteria (MDC) for the permitting of Gravity Sewers (latest version), and MDC for the Permitting of Pump Stations and Force Mains (latest version)? If not, a variance approval is required in accordance with 15A NCAC 02T.0105(b), prior to certification and operation. • Contact the Central Office to discuss the variance to determine a course of action. • Applicant must submit two copies of the variance request form, plans, specifications, calculations, and any other pertinent information to the Central Office (one hard copy, one digital copy). • The central office will review the variance request, and if approvable, specific language regarding the variance will be incorporated into the permit, either via a special condition or a supplementary letter. A copy of the reissued permit with variance language or the variance letter must be maintained with the original documents. 7) Does the project contains high priority lines (15A NCAC 02T .0402(2))? ❑ Yes ❑ No • If yes, ensure that the permit already contains the necessary condition related to high priority lines 15A NCAC 02T.0403 (a)(5). If the permit does not include this language, the Fast Track reviewer will reissue the permit with the appropriate language. 8) Are Permit modifications are required for any changes resulting in non-compliance with this permit (including pipe length difference of 10% or greater, change in flow, pump station design capacity design change of 5% or greater, and change in the number/type of connections)? ❑ Yes ❑ No • If yes, a permit modification request must be submitted to the appropriate Regional Office, and a modified permit with revised certification must be issued prior to certification and operation.