HomeMy WebLinkAboutNCG550833_Inspection_20240626
June 26, 2024
Soraya Galdamez
220 Mickey Circle
Durham, NC 27712
Subject: Compliance Evaluation Inspection
Single Family Wastewater Treatment System
General NPDES Permit NCG550000
Certificate of Coverage NCG550833
Facility: 220 Mickey Circle, Durham, NC 27712, Durham County
Dear Ms. Galdemez:
On June 18, 2024, Tyler Clark and Kurtis Waibel from the Raleigh Regional Office visited your single-
family residence (SFR) wastewater treatment system to evaluate compliance with the subject General
NPDES Permit. The assistance you provided over the telephone was greatly appreciated.
Our records indicate the treatment system consists of a septic tank, sub-surface sand filter, tablet
chlorinator with chlorine contact chamber, and discharge pipe.
General NPDES Permit NCG550000 and Certificate of Coverage (COC) NCG550833 authorize the
discharge of domestic wastewater from your treatment system to receiving waters designated as unnamed
tributary to Little River(classified WS-IV, NSW) in the Neuse River Basin. The authorized discharge is
in accordance with the effluent limits and monitoring requirements established within the General Permit.
The items below show what conditions were noted at your facility:
Findings during the inspection were as follows:
1. Treatment system operation: The wastewater treatment system shall be maintained at all
times to prevent seepage of sewage to the surface of the ground.
2. Pumping the septic tank: You are required to inspect the septic tank at least yearly to
determine if solids must be removed or if other maintenance is necessary. Septic tanks
should be pumped out every five years or when the solids level is found to be more than
1/3 of the liquid depth in the septic tank compartment, whichever is greater. A pumping
company can check the status periodically and determine when pumping is required.
Within 30-days of receiving this letter, please send a copy of the most recent
receipt/invoice to this office showing the date the septic tank was last checked and/or
pumped out. The General NPDES Permit requires the permittee to retain records
associated with sewage disposal activities for a period of at least 5 years.
DocuSign Envelope ID: DAE8613C-CA13-4C84-8DA1-F4C994AE8251
Soraya Galdemez, NCG550833
June 26, 2024 Page 2 of 3
3. Chlorine tablets in the chlorinator: You are reminded that it is required that chlorine
tablets be maintained in the chlorinator to ensure proper disinfection of the discharged
wastewater. Chlorine tablets provide effective disinfection and prevent/limit harmful
bacteria from discharging to the environment. The product label for these tablets must
indicate the tablets are approved for wastewater use and not for swimming pools. Part 1,
Section D (1) of General NPDES Permit NCG550000 requires the permittee to inspect the
tablet chlorinator weekly to ensure there is an adequate supply of tablets for continuous
and proper operation. Section D (4) requires the permittee to maintain all system
components, including...disinfection units...at all times and in good operating order. The
inspector did not observe any chlorine tablets in the chlorinator. Please ensure the correct
type of tablets are used and maintained in the chlorinator as required by the General
NPDES Permit.
4. Analyzing the effluent: Part 1. C., Effluent Limitations and Monitoring Requirements,
within General Permit NCG550000 requires a permittee to sample and analyze the effluent
leaving his/her treatment system prior to discharge annually. Parameters to be sampled
and analyzed include Flow, BOD (Biochemical Oxygen Demand), Total Suspended Solids,
Fecal Coliform, Total Residual Chlorine, Total Nitrogen, Ammonia Nitrogen and Total
Phosphorous. Within 30-days of receiving this letter, please let this office know if you
have monitored your effluent discharge within the last 12 months, and provide this office
with a copy of the lab results if you have. If you have not monitored your effluent, then
please collect a representative sample of the effluent, have it analyzed by a certified
commercial laboratory and submit the results to this office no later than August 30, 2024.
If, during this time, you are unable to collect a representative sample of the effluent
discharge due to insufficient flow from the discharge pipe, then update this office with that
information and continue to monitor the discharge and if conditions for sampling become
favorable, then arrange to collect a sample. Failure to monitor the effluent discharge as
required is a violation of NPDES General Permit NCG550000.
5. Discharge outlet location. The permittee is required to conduct a visual review of the
outfall location at least twice each year (one at the time of sampling) to ensure that no
visible solids or other obvious evidence of system malfunctioning is observed. Any visible
signs of a malfunctioning system shall be documented, and steps taken to correct the
problem. The end of discharge pipe was not visible nor accessible the day of the
inspection. To comply with the general permit monitoring requirements, you need to be
able to sample and analyze the effluent from your SFR system through the discharge pipe.
You need to keep the area around the discharge pipe cleared of vegetation, soil and leaves.
Please take the necessary steps to ensure the discharge outlet is visible and accessible.
Maintaining the area will allow you to monitor the discharge and to collect effluent
samples as required by the subject permit.
Part II Section B.14 of General Permit NCG550000 requires the permittee to “pay the annual
administering and compliance monitoring fee within thirty days after being billed by the Division.”
Division records indicate the required annual fee ($60 per year) for the period ending September 30, 2024,
and due November 3, 202, has been paid. There are no overdue fees for the subject COC.
DocuSign Envelope ID: DAE8613C-CA13-4C84-8DA1-F4C994AE8251
Soraya Galdemez, NCG550833
June 26, 2024 Page 3 of 3
The wastewater treatment system should be periodically inspected to ensure the treatment components are
always maintained and in good operating order. You are also reminded to maintain all monitoring data
and associated maintenance records onsite for a minimum of three years and available for inspection.
Within 30-days receipt of this letter, please submit a written response to this office indicating the
actions you will take or have taken to comply with or resolve the issues noted items #2-5 above.
If you have questions or comments about this inspection or the requirements to take corrective action (if
applicable), then please contact Tyler Clark at 919-791-4242 or by email at timothy.clark@deq.nc.gov.
Sincerely,
Vanessa E. Manuel, Assistant Regional Supervisor
Water Quality Regional Operations Section
Raleigh Regional Office
Division of Water Resources, NCDEQ
Attachment(s): EPA Water Compliance Inspection Report
Cc: RRO/SWP Files
Laserfiche
DocuSign Envelope ID: DAE8613C-CA13-4C84-8DA1-F4C994AE8251
EPA
United States Environmental Protection Agency
Washington, D.C. 20460
Water Compliance Inspection Report
Form Approved.
OMB No. 2040-0057
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1 N 52 NCG550833 24/06/18 C S31112171819 20
21 66
Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ----------------------Reserved-------------------
N67707172 73 74 75 80
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
POTW name and NPDES permit Number)
220 Mickey Circle
220 Mickey Cir
Durham NC 27712
Entry Time/Date Permit Effective Date
Exit Time/Date Permit Expiration Date
09:30AM 24/06/18 13/08/01
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
///
Other Facility Data
10:15AM 24/06/18 18/07/31
Name, Address of Responsible Official/Title/Phone and Fax Number
Soraya Galdamez,220 Mickey Cir Durham NC 27712///Contacted
No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit Operations & Maintenance Records/Reports Facility Site Review
Effluent/Receiving Waters
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s)Agency/Office/Phone and Fax Numbers Date
Timothy Clark DWR/RRO WQ/919-791-4234/
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
Page#1
6/25/2024
DocuSign Envelope ID: DAE8613C-CA13-4C84-8DA1-F4C994AE8251
6/27/2024
NPDES yr/mo/day
24/06/18
Inspection Type
C3111218
1
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
NCG550833 17
Page#2
DocuSign Envelope ID: DAE8613C-CA13-4C84-8DA1-F4C994AE8251
Permit:NCG550833
Inspection Date:06/18/2024
Owner - Facility:
Inspection Type:
220 Mickey Circle
Compliance Evaluation
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping?
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment:
Permit Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new
application?
Is the facility as described in the permit?
# Are there any special conditions for the permit?
Is access to the plant site restricted to the general public?
Is the inspector granted access to all areas for inspection?
Permit expired 07/30/2018.Comment:
Page#3