Loading...
HomeMy WebLinkAboutNC0026921_Compliance Reconnaissance Inspection (Fran)_19960926p- 2. y,d 17. (GPI W/ State of North Carolina Department of Environment, Health and Natural Resources Fayetteville Regional Office James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary Mr. Dan Webb Town of Parkton PO Box 55 Parkton, NC 28371-0055 7,F5Ti A .Nr„ OEHNR DIVISION OF WATER QUALITY September 26, 1996 SUBJECT: COMPLIANCE RECONNAISSANCE INSPECTION Town of Parkton WWTP NPDES Permit No. NC0026921 Robeson County Dear Mr. Webb: Please find enclosed a copy of the Compliance Reconnaissance Inspection for the inspection conducted September 25,1996. The inspection was conducted in part as a follow-up to hurricane "Fran" that impacted numerous wastewater treatment and collection facilities in North Carolina. The report should be self-explanatory and contains information obtained during the inspection. Should you discover damage to .the wastewater treatment or collection system not previously reported, please FAX an updated report to this office at (910) 486-0707 as soon as possible. If you have any questions or comments concerning this report, please do not hesitate to contact me or Michael Wicker, P.E., Regional Water Quality Supervisor, at (910) 486-1541. Sincerely, Grady Dobson Environmental Engineer II GD/bs Enclosure cc: Bob Sledge, DEM Compliance Group Wachovia Building, Suite 714, Fayetteville North Carolina 28301-5043 Voice 910-486-1541 NOC FAX 910-486-0707 An Equal Opportunity Affirmative Action Employer 50% recycled/10% post -consumer paper RECONNAISSANCE INSPECTION FROM HURRICANE FRAN WWT FACILITY Town of Parkton PERSON CONTACTED Dan Webb DWQ INSPECTOR Grady Dobson COUNTY Robeson POWER OUTAGE WHEN OUT WHEN RETURNED UNITS OUT LIST YES [X] 9/5/96 8:45 p.m. 9/9/96 12:30 p.m. 9/6/96 - 6:30 a.m. Generator took over. Power outage NO [ ] BYPASS None approximately 12 hours. PUMP STATIONS POWER OUT POWER ON CORRECTIVE MEASURES 2 9/5/96 8:45 p.m. 9/9/96 12:30 p.m. OVERFLOWS FROM PUMP STATIONS WHERE CORRECTIVE ACTION None Backed -up in Town system until generator took over. COLLECTION SYSTEM YES NO STATUS OVERFLOWS - [ ] IX] FLOODING [] [X] Some in Town but not in collection system. Flow parameters may exceed monthly average. SAMPLING MISSED [ ] [X] VIOLATIONS OF PERMIT CODES [ ] [X] GOOD BAD EFFLUENT QUALITY X _ STREAM QUALITY X _ Typical swamp like conditions Tanic water - slow flow FISH KILLS None ESTIMATED COST OF DAMAGES $ 1,225 Aerator Tubes $ 75.00 Generator Repair$300.00 Light Poles $350.00 Fence Repairs $150.00 Chlorine Contact $350.00 Cleaning COMMENTS: This facility was roughly out of power for 12 hours. An auxiliary generator took control on 9/6/96, and was utilized until power came on - 9/9/96. No sewer manhole overflows in the Town were observed. The plant now appears to be normal except for sand and debris washed in by excessive flow.