Loading...
HomeMy WebLinkAboutNC0007064_Monitoring (Report)_20231108Brunswick Steam Electric Plant (BSEP) Supplemental Information for Thermal Plume: A. (1) EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS [Outfall 001] [15A NCAC 026.0400 et seq., 15A NCAC 0213.0500 et seq.] Criteria: TEMPERATURE — Cooling -water system facilities shall be effectively maintained and operated to meet the temperature standards assigned to the Atlantic Ocean: 0.8°C (1.447) increase above ambient water temperature during the months June through August; 2.2°C (3.96°F) increase above ambient water temperature during the months September through May. In no case should the temperature exceed 32°C (89.6°F) due to the discharge of heated liquid measured three (3) feet below the water surface except within the following defined mixing zones: (a). The temperature increase above ambient water temperature shall not exceed 7°F outside an area of 120 acres included within the plume extending from the point of discharge. (b). The temperature increase above ambient water temperature shall not exceed 0.8°C (1.44°F) increase above ambient water temperature during the months of June through August; 2.2°C (3.967) increase above ambient water temperature during the months of September through May. In no case should the temperature exceed 32°C (89.6'F) outside an area of 2000 acres. (c). The temperature increase above ambient water temperature at the bottom (defined as one foot above the ocean floor) shall not exceed 7°F for more than 1000 feet from the point of discharge, nor for an area of more than four (4) acres. Temperature monitoring at the ocean discharge shall be conducted semiannually, once during the months of April - November and once during the months of December- March. Reactor power levels should be at least 85% for each unit on the date of monitoring. If it is determined by this Division that the water quality standards or conditions of this permit are being violated or being threatened (within 90% of the limitations or standards), additional monitoring may be required. Temperature shall be monitored within a 2320-acre rectangular mixing zone defined by two (2) sampling grids; one near the ocean surface (three feet below the water surface) and the second near the bottom (one foot above the ocean floor). Temperatures shall be recorded at locations sufficient in number to establish compliance with Water Quality Standards. The Permittee shall likewise establish and report ambient temperatures beyond each grid by averaging four (4) temperature measurements -- each measurement to be taken approximately 1500 feet beyond a different mixing -zone corner on a baring approximately 1352 relative to each sampling grid except for the corners closest to the shoreline which are to be taken 1500 feet from the grid parallel to the shoreline. Conclusion: Temperature monitoring is performed by plant procedure OE&RC-3227, Thermal Plume Monitoring. Monitoring was performed on 11/08/2023. All measured parameters were within the guidance specified by the BSEP NPDES permit. THERMAL PLUME MONITORING OE&RC-3227 Rev. 6 Page 14 of 18 ATTACHMENT 4 << BNP Thermal Plume Monitoring Log >> Page 1 of 2 Date 11/8/2023 Wind Direction SE Unit 1 Wind Speed 6 MPH Unit 2 Air Temperature 67.1 Tide Stage Power 99.0 100.0 Low/Rising Station Time Surface Temp Bottom Temp. 1 N/A N/A N/A 2 12:06 66.1 65.9 3 12:04 66.5 N/A 4 12:03 67.1 N/A 5 12:01 67.5 N/A 6 11:58 67.5 N/A 7 11:56 67.7 N/A 8 11:55 67.9 N/A 9 11:53 67.6 N/A 10 11:52 67.3 N/A 11 11:50 68.2 N/A 12 11:48 66.4 65.1 13 N/A N/A N/A 14 11:45 65.8 N/A 15 12:28 67.3 N/A 16 12:27 68.1 N/A 17 12:25 67.8 N/A 18 12:24 67.8 N/A 19 12:22 68.2 N/A 20 12:20 67.5 N/A 21 12:16 67.8 N/A 22 12:14 67.9 N/A 23 12:12 66.9 N/A 24 12:10 66.5 N/A 25 12:47 66.5 N/A 26 12:45 66.7 N/A 27 12:43 68.1 N/A 28 12:42 68.7 N/A 29 12:40 68.4 N/A 30 12:38 68.1 N/A 31 12:37 68.4 N/A 32 12:35 67.9 N/A THERMAL PLUME MONITORING OE&RC-3227 Rev. 6 Page 15 of 18 << BNP Thermal Plume Monitoring Log >> ATTAC;HMEN 1 4 Page 2 of 2 Station Time Surface Temp. Bottom Temp. 33 12:33 67.9 N/A 34 12:31 68.2 N/A 35 11:42 66.2 N/A 36 N/A N/A N/A 37 11:37 65.9 64.9 38 11:35 65.8 N/A 39 11:33 67.1 N/A 40 11:31 68.4 N/A 41 11:30 66.9 N/A 42 11:28 67.9 N/A 43 10:31 66.4 N/A 44 10:29 66.4 N/A 45 10:27 66.1 N/A 46 10:25 65.9 N/A 47 10:22 65.5 65.3 48 N/A N/A N/A 49 10:45 N/A 67.1 50 10:42 N/A 65.2 51 11:00 N/A 65.9 52 10:40 N/A 66.5 53 11:24 N/A 68.3 54 11:12 N/A 65.4 55 11:06 N/A 65.3 56 10:38 N/A 67.8 57 11:27 66.7 N/A 58 11:13 66.9 N/A 59 11:07 68.3 N/A 60 10:35 69.1 N/A 61 j 10:47 74.3 69.6 Ambient Temperature: Surface: 66.0 Bottom: Temperature Meter Serial Number: 4009314 Probe Serial Number: Calibration Due Date: 9/22/2024 Data Collected by: Wirth Wei mop Babson, Kelli Davis 65.3 CP3166512 Reviewed by: '�//;e'.l /4 �✓6�c �r°i`^'- n/e- r 5- m N O N 00 W F- Q z a z Ln Lrj LD Ln LD LD Ln LO LD r 1.0 LD rq m Lri lD LO LD rn �.o LD Ln tD LD ci lD LD rl 00 LD C 1 r; lD r` lD Z i Q i Q t = 2 r` t LD LL o o U) E Z ~ E N a) - L' O W O1 d E LnN O 'G O Q LD LD 00 LD Ln LD CL d U E N L cu r4 N =C E L Y � G F E 0 w lD 00Q LD Ln LD Ln LD V I Q1 LD c-f 00 W N 00 W r` Lo co = w U a w o- m LU C9 —, 0 d 00 o J ' _ Q� N r X � O p O� ttDD. 01 00 lD lD U a �, n wIR /w Ln v 0 rn 0 0 m Lo N in W N uj m °i Q � Q 00 Ln LD N 00 lD rq r\ LD N 00 LD N L O a V m W p� Ln lD N CD LD 00 Ln lD d LD Lo Q z W H Q O z z .T. U W m J W U a W Z o ^ CL W Cl) Z a W V a L,L Cl) a uj U U o IV) a c» N O N 00 ci W H Q M N M LM i� U VI in M o6 lD KOM Uj H FQ- Z (A W_ W m 0 � 1- Q 3: V MW J J W ui w Cl) a U Ief� z W 0 CL a M W o W Z a a O N W O a a m W C7 a� 2 N vo Co o � W h Q Lr 0 0 0 CLO V L Lj t0 m l0 N l0 Q1 l0 N O M Ln N m L V cc o= N d 2 � N i LL N i N Q. Qi L L L 'a t H � 0 �L z c� bn C LI m 3 � 0 W W C9 z (n W_ W m 0 � 1- a