Loading...
HomeMy WebLinkAboutSW6240608_Supplement-EZ Form_20240625 SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION 1 Project Name Caropines Phases 3A/7A 2 Project Area ac) _ 15.81 3 Coastal Wetland Area(ac) �v- 4 Surface Water Area(ac) - 5 Is this project High or Low Density? { High 6 Does this project use an off-site SCM? No COMPLIANCE WITH 02H.1003(4) 7 Width of vegetated setbacks provided(feet) N/A 8 Will the vegetated setback remain vegetated? N/A 9 If BUA is proposed in the setback,does it meet NCAC 02H.1003(4)(c-d)? No 10 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: 11 Infiltration System I 2 12 Bioretention Cell _ 0 13 Wet Pond _ 1 14 Stormwater Wetland 0 15 Permeable Pavement 0 16 Sand Filter 0 17 _ Rainwater Harvesting(RWH) 0 18 Green Roof 0 19 Level Spreader-Filter Strip(LS-FS) 0 20 Disconnected Impervious Surface(DIS) 0 21 1Treatment Swale 0 22 D Pond 0 23 StormFilter _ 0 24 Silva Cell 0 25 Bayfilter 0 26 Filterra 0 FORMS LOADED 1 DESIGNER CERTIFICATION 27 Name and Title: Matt Lowder,PE 28 _Organization: Bowman North Carolina,Ltd. 29 Street address: 4006 Barrett Drive,Suite 104 30 ;City,State,Zip: Raleigh,NC 27609 _ 31 Phone number(s): 919-553-6570 32 Email: mlowder@bowman.com Certification Statement: I certify,under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision;that the information provided in the form is,to the best of my knowledge and belief,true,accurate,and complete;and that the engineering plans, specifications,operation and maintenance agreements and other supporting information are consistent with the information provided here. Designer Signature of Designer SEAL 051571 • • • £NGINE�.• ' p 5/ �o?`I //�icp'rti0„E, ��o\ Date DRAINAGE AREAS 1 Is this a high density project? Yes 2 If so,number of drainage areas/SCMs 3 ~3 :Does this project have low density areas? Nov 4 If so,number of low density drainage areas 0 Is all/part of this project subject to previous rule 5 versions? No FORMS LOADED T2-----p-- 3 DRAINAGE ofA SCMEA INFORMATION Entire Site Infiltration Basin Infiltration Basinet �-- Type • Pond 5 Total drainage area(sq ft) 952186 sf 95450 _&. 101415 755321 6 Onsite drainage area(sq ft) 952186 sf L 95450 101415 755321 7 Offsite drainage area(sq ft) sf 8 Total BUA in project(sq ft) 256050 sf 22955 sf _ 39164 sf 193931 sf ,New BUA on subdivided lots(subject to permitting) 9 (sq ft) New BUA not on subdivided lots(subject to 410 ,permitting)(sf) 11 Offsite BUA(sq ft) sf 12 Breakdown of new BUA not on subdivided lots: 4 -Parking(sq ft) _-Sidewalk(sq ft) 17882 sf 2975 sf 2689 sf 12218 sf -Roof(sq ft) 146520 sf 19980 sf 23310 sf 103230 sf -Roadway(sq ft) 91648 sf 13165 sf 78483 sf -Future(sq ft) -Other,please specify in the comment box below(sq ft) _ New infiltrating permeable pavement on 13 subdivided lots(sq ft) New infiltrating permeable pavement not on 14 subdivided lots(sq ft) Existing BUA that will remain(not subject to , 15 permitting)(sq ft) 16 Existing BUA that is already permitted(sq ft) _ ' 17 Existing BUA that will be removed(sq ft) - 18 Percent BUA 24% 39% 26% 19 Design storm(inches) 1.0 in _ 1.0 in _ 1.0 in `.20 Design volume of SCM(cu ft) _ 2119 cf t 3360 cf � . 17692 cf 21 Calculation method for design volume Simple Method Simple Method Simple Method ADDITIONAL INFORMATION Please use this space to provide any additional information about the 22 drainage area(s): INFILTRATION SYSTEM 1 Drainage area number 1 2 2 Minimum required treatment volume(cu ft) 2119 cf 1 3360 cf :GENERAL MDC FROM 02H.1050 mom- 3 Is the SCM sized to treat the SW from all surfaces at build-out? Yes Yes 4 Is the SCM located away from contaminated soils? Yes Yes 5 What are the side slopes of the SCM(H:V or enter"Vertical"for trenches)? 3:1 3:1 6 Does the SCM have retaining walls,gabion walls or other engineered side slopes? No No 7 Are the inlets,outlets,and receiving stream protected from erosion (10-year storm)? Yes Yes 8 Is there an overflow or bypass for inflow volume in excess of the design volume? i Yes Yes - 9 What is the method for dewatering the SCM for maintenance? ` Pump(preferred) Pump(preferred) 10 If applicable,will the SCM be cleaned out after construction? Yes Yes j i __ 11 Does the maintenance access comply with General MDC(8)? Yes Yes - 12 Does the drainage easement comply with General MDC(9)? Yes Yes 13 If the SCM is on a single family lot,does(will?)the plat comply with General MDC(10)? N/A N/A 14 Is there an O&M Agreement that complies with General MDC(11)? Yes Yes 15 Is there an O&M Plan that complies with General MDC(12)? Yes _ Yes 16 I Does the SCM follow the device specific MDC? Yes Yes 17 Was the SCM designed by an NC licensed professional? Yes Yes INFILTRATION SYSTEM MDC FROM 02H.1051 18 Proposed slope of the subgrade surface(%) { 0% 0% 19 Are terraces or baffles provided? , No No - l_20 Type of pretreatment: f Forebay Forebay Soils Data 21 Was the soil investigated in the footprint and at the elevation of the infiltration system? Yes _ Yes 22 SHWT elevation(fmsl) 379.00 _ 368.10 _ 23 Depth to SHWT per soils report(in) 120.00 22.00 _ 24 Ground elevation at boring in soils report(fmsl) 389.00 370.00 25 Is a detailed hydrogeologic study attached if the separation is between 1 and 2 feet? Yes Yes 26 Soil infiltration rate(in/hr) 12.00 10.50 27 Factor of safety(FS) (2 is recommended): 2.00 2.00 Elevations 29 Bottom elevation(fmsl) 381 ft 374 ft 30 Storage elevation(fmsl) 383.ft 375.ft 31 ;Bypass elevation(fmsl) I 383.4 ft 375.75 ft For Basins Only 32 Bottom surface area(ft2) 1580 ft I 2845 ft 33 Storage elevation surface area() 2695.ft -- 4250.ft For Trenches Only 34 Length(ft) 35 Width(ft) 36 Perforated pipe diameter,if applicable(inches) 37 Number of laterals 38 Total length of perforated piping 39 Stone type,if applicable 40 Stone porosity(%) 41 Is stone free of fines? 42 Is the stone wrapped in geotextile fabric? 43 Has at least one inspection port been provided? Volumes/Drawdown 44 Design volume of SCM(cu ft) 2119 cf I 3360 cf 45 Time to draw down(hours) 72 hrs 72 hrs ADDITIONAL INFORMATION 46 Please use this space to provide any additional information about the infiltration system(s): Infiltration 1 8:40 AM 5/29/2024