HomeMy WebLinkAboutSW4230701_Supplement-EZ Form_20240621 DocuSign Envelope ID: 1 EF6A072-09C7-43E3-B13D-4A1A0F55F141
SUPPLEMENT-EZ COVER PAGE
FORMS LOADED
jROJECT INFORMATION
1 Project Name High Meadows,Sec 2
2 Project Area(ac) 14.84
3 Coastal Wetland Area(ac) _ _ 0
4 Surface Water Area(ac) 0.073
5 Is this project High or Low Density? Low
6 Does this project use an off-site SCM? No
COMPLIANCE WITH 02H.1003(4)
7 Width of vegetated setbacks provided(feet) 30
8 Will the vegetated setback remain vegetated? Yes
9 If BUA is proposed in the setback,does it meet NCAC 02H.1003(4)(c-d)? N/A
10 Is streambank stabilization proposed on this project? No
NUMBER AND TYPE OF SCMs: •
11 'Infiltration System
12 Bioretention Cell
13 Wet Pond
14 Stormwater Wetland
15 Permeable Pavement
16 Sand Filter
17 Rainwater Harvesting(RWH)
18 Green Roof
19 Level Spreader-Filter Strip(LS-FS)
20 Disconnected Impervious Surface(DIS)
21 Treatment Swale
22 Dry Pond
23 StormFilter
24 Silva Cell
25 Bayfilter
26 Filterra
FORMS LOADED
DESIGNER CERTIFICATION
27 Name and Title: Alex Carter,PE
28 Organization: Beeson&Carter,PA
29 Street address: 4510 Reidsville Road
30 City,State,Zip: Winston Salem,NC 27101
31 Phone number(s): 336-748-0071
32 Email: acarter@bc-eng.com
Certification Statement:
I certify,under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision;that the
information provided in the form is,to the best of my knowledge and belief,true,accurate,and complete;and that the engineering plans,
specifications,operation and maintenance agreements and other supporting information are consistent with the information provided here.
Designer
O▪ S /0C/,17\,
Signature of Designer
• 038574
•
'V s',▪••.4/GINEde
T"C � •��` 6/21/2024 6/21/2024
Date
DocuSign Envelope ID: 1 EF6A072-09C7-43E3-B13D-4A1A0F55F141
DRAINAGE AREAS
1 Is this a high density project? No
2 If so, number of drainage areas/SCMs 0
3 Does this project have low density areas? Yes
4 If so, number of low density drainage areas 1
Is all/part of this project subject to previous rule
5 versions? No
FORMS LOADED
DRAINAGE AREA INFORMATION Entire Site LD 1
4 Type of SCM Vegetated Vegetated
5 Total drainage area (sq ft) 646565 646565
6 Onsite drainage area (sq ft) 646565 646565
7 Offsite drainage area (sq ft)
8 Total BUA in project(sq ft) 138350 sf 138350 sf
New BUA on subdivided lots (subject to
_ 9 permitting) (sq ft) 88000 sf 88000 sf
New BUA not on subdivided lots (subject to
10 permitting) (sf) 50350 sf 50350 sf
11 Offsite BUA(sq ft)
12 Breakdown of new BUA not on subdivided lots:
- Parking (sq ft) sf
-Sidewalk (sq ft) sf
- Roof(sq ft) sf
- Roadway(sq ft) 50350 sf 50350 sf
- Future (sq ft) sf
-Other, please specify in the comment box
below(sq ft) sf
New infiltrating permeable pavement on
13 subdivided lots (sq ft) sf
New infiltrating permeable pavement not on
14 subdivided lots (sq ft) sf
Existing BUA that will remain (not subject to
15 permitting) (sq ft) sf
16 Existing BUA that is already permitted (sq ft) sf
17 Existing BUA that will be removed (sq ft) sf
18 Percent BUA 21% 21%
19 Design storm (inches)
20 Design volume of SCM (cu ft)
21 Calculation method for design volume
ADDITIONAL INFORMATION
Please use this space to provide any additional information about the
22 drainage area(s):
See sheet C-4.1 for more details on drainage areas. Site is low density and
uses vegatated conveyances to the maximum extent pratical.
DocuSign Envelope ID: 1 EF6A072-09C7-43E3-B13D-4A1A0F55F141
LOW DENSITY
DESIGN REQUIREMENTS FOR LOW DENSITY PROJECTS FROM 02H.1003
1 Is project below density thresholds set forth in the applicable stormwater rule? Yes
2 Does project maximize dispersed flow and minimize channelization of flow? Yes
3 Has the use of piping been minimized per.1003(2)(c)? Yes
4 Side slopes of the vegetated conveyances(H:V) 3:1
5 Maximum velocity in the vegetated conveyances during the 10-year storm? 8.10
6 Are curb outlet swales proposed? No
7 Maximum longitudinal slope of curb outlet swale(s)(%) _
8 Bottom width of curb outlet swale(s)(feet)
9 Maximum side slope of curb outlet swale(s)(H:V)
10 Minimum length of curb outlet swale(s)(feet) _
11 Are treatment swales used instead of curb outlet swales? Yes
12 Is stormwater released at the edge of the setback as dispersed flow? Yes
13 Have stormwater outlets been designed to prevent downslope erosion? Yes
14 Are variations to rule.1003 proposed? No
ADDITIONAL INFORMATION
15 Please use this space to provide any additional information about this low density project:
This site is the final phase of an existing residential development with lots platted in 1975,1978 and 1995. The site will utilize
side ditches that are periodically piped for outletting between lot areas in keeping with existing ties to ribbon pave/side ditch stub
streets. Piping is periodically needed to prevent excessive storm water buildup in the side ditches creating greater possibility of
erosion. All piped side ditch piping outlets to riprap outlet aprons and vegetated swales that meet the MDC requirements to
disperse the flow on the low side of the site. No SCMs are proposed for this site.
Drainage Pervious
Swale Area BUA area C Q Slope Vallow Va«ua, Flow depth
# (ac) (ac) (ac) (cfs) (%) (fps) (fps) (ft)
1 2.11 0.41 1.70 0.40 5.83 1.21 5.00 2.57 0.87
2 0.51 0.11 0.40 0.40 1.34 1.21 5.00 1.79 0.50
3 2.62 0.00 2.62 0.40 7.17 12.90 9.50 8.10 0.30
4 0.77 0.28 0.49 0.40 2.13 10.50 5.00 4.44 0.40
5 0.87 0.32 0.55 0.40 2.40 6.10 5.00 3.78 0.46
6 1.57 0.62 0.95 0.65 7.05 10.50 9.50 7.76 0.55
7 0.46 0.07 0.39 0.40 1.27 11.95 5.00 4.13 0.32
8 0.82 0.16 0.66 0.40 2.27 11.95 5.00 4.73 0.40
9 1.09 0.16 0.93 0.40 3.01 2.89 5.00 2.98 0.58
10 0.76 0.12 0.64 0.40 2.10 2.89 5.00 2.69 0.51
11 0.84 0.12 0.72 0.40 2.32 2.89 5.00 2.75 0.53
12 1.14 0.16 0.98 0.40 3.00 20.80 9.50 5.73 0.12
13 0.87 0.16 0.71 0.40 2.30 18.60 9.50 4.78 0.12
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30