HomeMy WebLinkAboutSW6230804_Plansheet - Proposed Conditions/Site Plan_20240621 SITE NOTES:
X
1. ALL SIGNS SHOULD USE PRISMATIC SHEETING THAT MEETS MINIMUM o N
RETROREFLECTIVITY STANDARDS FOUND IN THE LATEST EDITION OF THE MUTCD. v
w
N
2. ALL CONSTRUCTION MUST BE PERFORMED IN ACCORDANCE WITH HARNETT COUNTY, "'
az NCDOT,AND NCDEQ STANDARD SPECIFICATIONS AND DETAILS. Coo s o Q w
z > o - > U
O � ouiof � (n
3. ALL ASPHALT EDGES SHALL BE SAW CUT TO PROVIDE A GOOD LONGITUDINAL JOINT. w u � c�
MILL 1.5 FEET AT 1.5 INCHES DEEP MINIMUM TO PROVIDE A LONGITUDINAL LAP JOINT w = o o o
JOE E.WHITE I JOE E.WHITE FOR FINAL SURFACE LAYER. NO MILLING SHALL BE LEFT FOR A PERIOD OF TIME o Of Lu� 0 0
I F MELANIE T.WHITE coou
GREATER THAN 48 HOURS BEFORE A STREET IS TO BE PAVED/RESURFACED. z
MELANIE T.WHITE 0 0
DB.1197, PG.490 DB.1371,PG.356
II PC#F,SLIDE 708E I MB.99,PG.385 4. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING AND PAYING FOR ANY PERMITS
/-(;VING:RA-30 / 1 1 I ZONING:RA-30 - AND/OR CONNECTION FEES REQUIRED TO CARRY OUT THE WORK.
EIP S\ 851d15Q» 50 -�- I I TODD P.DENNIS 5. CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL GRADES PRIOR TO THE START OF o o N o co
o N
S05�°39' 2. 4" �58 Y'p6 9�� I CHRISTIANA E.W.DENNIS
-�. CONSTRUCTION. N N M N N o
0.0 ,[50.91 DB.3249,PG.960 `V
M6.2014,PG.256 257 6. EXISTING UTILITY LOCATIONS SHOWN ARE APPROXIMATE AND SHALL BE FIELD o o o 0
/`�- ZONING:RA 30 VERIFIED. LU
z
\` C l �4$ r-- � -\ 7 PROPERTY LIONS UNLESSO EDGE S OWNOOTHERWESE., FACE OF CURB, FACE OF BUILDING, OR
/L DIRT DR `�8 �i �•5 J
APPRAT V E 5I
LOCA9TION� \ \ \ f \ 8. TACTILE WARNING MATS ARE TO BE INSTALLED ON ALL WHEELCHAIR RAMPS.
5p, \ -
9. ALL PARKING STALL MARKINGS AND LANE ARROWS WITHIN THE PARKING AREAS
o a o �\ / RESS EGR S GRE\ \ \- ® \ _ SHALL BE WHITE.
O N N I f- o Z 7 w I
O cn \S E SS&U I CC
Q v M 20/ P 5jCD
ITET S,14' 10.26y1L 10. MAX. SIDEWALK CROSS SLOPE IS 2%.
Z — 1 _
U I � o I � m \_ \ I 50.38
z V =1 ui
0 I� (D ,\ NC GRID COORDINATES(NAD 83)
/�j N=657,097.847
Lijo z aSITE/ ^ E040,242.531 LEGEND: Q
W
Y - - - - /�' �, SUP BOUNDARY
O _ --mums-� \ PHASE LINE O
e, 1 o� _® SELF-STORAGE PROPERTY BOUNDARY
/ \ PAUL E.DAVIS,JR. --
S 86°58 2g W 181 .J / �� CANOPY SAMANTHA A.DAVIS
EASEMENT LINE
/ DB.2619,PG.255 M BUILDING --- � SURFACE � / � PROPERTY BOUNDARY - - - - - - - SETBACK LINEco
/ 4,000 SF \ E STORAGE
MB.2009,PG.247 - BUFFER LINE ,
(FUTURE
FUT U Y — SCM LIMITS
BUILDING�3 �Q / \ ZONING:RA-30 —..-..-..
/ p1 CHAIN LINK FENCE
/ / ►-� S7 T �\� 8,000SF \ w WATERLINE
1Mai
l / \ � FIRE HYDRANT ASSEMBLY
W am
I ® � J ! / - 7 ►� GATE VALVE
\ \
P \ p „' „ TEE cn
APP 0 MAT l ASPHALT PAVEMENT zcn
C/L lR/E`OCAT/ l l
-
\ _� SSRE GRAVEL SURFACING
GRE - \ — — — — ►,
�� 8.2014 PRE T \ S P SIBL BOUNDARY LINE DISPUTE z a
\JUDY H.LAWRENGE� \ \ \\ - / / / ° / \ E MB.2G14,PG.257/ � p / ZONING:RA-30 STORAGE BUILDING
MB.2007,PG.896
ZONING:RA-30
- -0�jn ____ o ) IuiUZI-
j \
Pc
Nt —b — �— — -- — -- \\ —®-�—\ ROPERTY
OUTSIDE
OF SUP r�
128247 SQFT. (O
2.94 AC. - I
I A,, / \ \ EMILY�M RGAN,
TRU
DB.2201, PG.160
ZONING:I A-30
EXISTING �\ �� -�— - . A A —� CN
WETLANDSIV 0
04
>U
I \N1
4 STORMWATER
— MANAGEMENT AR \ LL
IL Cj D
HLI
J
Lu
_ - — BEFORE YOU DIG, co
0
N--8-9'44,42 VV -8�59--29 l\ \\ \ \� _EI
P \ CALL CA N
Lo In
\ \ Lo Lo
Lu
Lu
z SARAH K.MASHBURN \ I
D6.3655,PG.224Lu
_
ZONING:RA-30 I � o bN'
N
I NORTH CAROLINA z o
z ONE CALL CENTER z
www.ncocc.org �d� ��
U �� w N� U
z
z
SCALE: 1 IN=60 FT
w
CD
60' 30' 0 60' 120'
0
w SCALE IN FEET
z HORIZONTAL
U
z
0
W
CD
SEAL
\`�1111lff/i!
1
N
o � •�FESS/�
N
N
O
z S w W EAL W
0
CO
04$ 84
ui
w
• , W
O.
w�
NOT FOR CONSTRUCTION y C-OZ
J