HomeMy WebLinkAboutWQ0044093_Toyota_802_Lift_Station_Wet_Well_Markups_2024062427 0 K 1/2" S ATE STRAI TYP 1 1/2" "0 X 4" NUTS (TY 1/2" TF I V 'X 4"X 1/ L ...... JJ 1 (SHOE -BEND ENDS UP 1/2") CASING SECTION J.NOTE* USE RACIO HDPE SPACERS, TYPE G, IN LIEU OF STEEL SPACERS WHERE INDICATED ON DRAWINGS. STEEL SPIDER DETAIL NOT TO SCALE STD WT STL PIPE SLEEVE, GALV AFTER FABRICATION ANNULAR LINK -SEAL v PROVIDE SINGLE ROW OF SEALS FOR PIPES d o LESS THAN 16" DIA. v PROVIDE DOUBLE ROW PIPE THRU s OF SEALS FOR PIPES 16" WALL OR FLOOR v DIA AND LARGER. ANNULAR SEAL PIPE THRU WALL OR FLOOR d n e AS RECOMMENDED d o WALL SLEEVE v BY ANNULAR SEAL d o MANUFACTURER d v AS RECOMMENDED T/2 BY ANNULAR 1/4"x3" STEEL P L T SEAL MFR SEEP RING > 8" INTERIOR, DRY T/2 BURIED, WET OR NOTE: TYPICAL PENETRATION OF BURIED DIP THROUGH OR TOP SIDE T<8„ BOTTOM SIDE CONCRETE PRECAST STRUCTURE UNLESS OTHERWISE ����► INDICATED. PENETRATION THROUGH PRECAST CONCRETE DETAIL NOT TO SCALE 12'-0" MAXIMUM BETWEEN SPACERS INSTALL THREE CASING SPACERS PER PIPE JOINT AS REQUIRED TO MEET MAXIMUM SPACING SUCTION PIPE EMERGENCY 10' X 10' PRECAST CONCRETE BYPASS CONNECTION WET WELL SEE DETAIL 5/01D-04 72" X 48" DOUBLE LEAF • , . , , • ALUMINUM ACCESS HATCH PVC 8" INFLUENT SEWER • ' / PVC 8" INFLUENT SEWER • �F ° ° I� li 3" PVC DRAIN. SLOPE TO WET WELL WITH P-TRAP I I °� 1°I WET WELL (L°1 1 II LLi - - II J0 ,. .„ VENT 6" DIP FLANGE BY PLAIN END PIPE COMPRESSION SLEEVE 7' X 6' DOUBLE LEAF ALUMINUM ACCESS HATCH 8' X 10' VALVE VAULT THRU ORT AND � —0 I 3E I 4 I I� g' 1°I 1°I TS h °I 1°1 II O �° PLAN NOTE: ALL MATERIALS AND FASTENERS SHALL BE 316 SS. 2' VALVES AND PIPES TO BE INSTALLED BY OTHERS LIFT STATION PLAN VARIES \ T-0" MAX TYP BOTH LEGS r ADJUST L3x3x3/8 TO MAINTAIN TOP LEG NORMAL TO PIPE C L 3/4" EPDXY ADHESIVE ANCHORS, TYPICAL CLCVfi I IVIV RISER PIPE SUPPORT DETAIL NOT TO SCALE 1'-6" (MAX' 6" (MIN) 1'-0" PLUG CARRIER PIPE Z_ STEEL CASING PIPE CASING SPACERS SHALL BE SPACED A MAXIMUM OF 1'-6" FROM EACH SIDE OF JOINT CASING END PLUGS 1. CASING SHALL BE PLUGGED ON BOTH ENDS BEFORE BACKFILLING. PLUGS SHALL CONSIST OF MINIMUM OF 1 LINEAR FOOT OF LOW STRENGTH GROUT (1,500 PSI MIN). 2. PROVIDE SIX-1/2" DIAMETER WEEP HOLES ON DOWNSLOPE SIDE OF CASING. TYPICAL PIPE CROSSING NOT TO SCALE NOT TO SCALE 'CH ANGLE BLEAR TS AS IUIRED TYP 20 D COUPLING ADAPTER 3/4" 0 SS EXP ANCHORS W/ 4" MIN EMBEDMENT 6" X 8" INCREASER WALL, FLOOR CY IL I OR CELLING Cn 6"XV TEE WITH BRANCH OUTLET FACING < UP WITH 6" VALVE AND PIPE TO EMERGENCY BYPASS (DETAIL 5) STL STRAP X"x3" VXV TEE WITH SIDE OUTLET ROTATED UP WITH BLIND FLANGE FOR ARV STEEL P ES" BOLTS, NUTS & WASHERS 72" x 48" ALUMINUM ACCESS HATCH WITH FALL PROTECTION GRATE AND PAD LOCK POST 10 TETHER CORD II —============--====-======--- AII I II I I II I II I I II I II I I I I I I II I I II I I I I --- I I I I I II iT r II I I I I I I I j1 I I it I I I I II I I I I III I I II I I I I 20 17 5/a O 17 I I I I p I I Il) I I I I I I I I IA I I I I I I I I I I n.I lill I I I I I I I I II ti� �X II I I I I I I I I -nIuIII --1III -'----- ------—r) d'--------III1 --- III��III — --------C— AL- rS�-T-- --A—J-Lrt—UII ---M—u- ItNnfI� UMIIIIIIIIIIIIII 7DROP HALE DROP HANDLE SLAMLOCK SLAMLOCK W/REMOVABLE KEY 1/4" FLOOR PLATE NOTES: (TOP PLATE) 1— MATERIAL: ALUMINUM SUPPORT CHANNEL 2— LOADING: DESIGNED FOR OFF STREET LOCATIONS WHICH MAY OCCASIONALLY RECEIVE H-20 WHEEL LOADS II _6" CAM & GROOVE 3— 316 STAINLESS STEEL NUTS & BOLTS COUPLING PLATE —6-3/4- DIA. HOLE IN BOTTOM PLATE FOR CONTRACTORS NPT PIPE BYPASS CONNECTION DETAIL NOT TO SCALE 3' MIN PIPE SIZE "D" < 2" 5/16" 1/4"x1" 1/4" 3"-4" 5/16" 1/4"x1" 1/2" 6"-8" 3/4" 3/8"x1 1/2" 1/2" NOTE: ALL MATERIALS AND FASTENERS SHALL BE 316 SS. OFFSET PIPE SUPPORT DETAIL NOT TO SCALE EMERGENCY BYPASS CONNECTION SEE DETAIL 5 CONCRETE WASH PAD J 0 a" 316 STAINLESS STEEL HOOKS FOR PUMP, PULL CHAINS, POWER CORDS, AND FLOAT HANGERS. MOUNT WITH 316 SST WEDGE ANCHORS (TYP) COORDINATE LOCATION WITH ENGINEER /OWNER PERSONNEL WASH PAD DRAIN WITH FLAPE VALVE 316 STAINLESS STEEL GUIDE RAILS WET WELL SUMP DETAIL NOT TO SCALE D BITUMINOUS JOINT MATERIAL (TYP) 3RAVITY SEWER IN (E): 692.93' 3RAVITY SEWER IN (W): 685.61' 0 316 SST UPPER GUIDE RAIL BRACKET LONG RADIUS 90' BEND TTOM WET WELL: 674.61' ' . Al. D 6" - DIP :Tr12" MINIMUM CLASS #57 CRUSHED STONE E LIFT STATION SECTION NOT TO SCALE 0 LU CJ w < 1 1/4 T/CONC. SLAB 1" NON -SHRINK GROUT, GALV. STEEL SHIMS AS REQ'D LOW PIPE SUPPORT TYPE 1 % NOT TO SCALE 3" SST VENT WITHHSSST NON- FERROUS INSECT SCREEN LOCATED ON HINGE SIDE OF PUMP ACCESS HATCH PROPOSED FINISHED GRADE: APPROX. 701.2' 2'-6" HAND WHEEL PUMPS, PIPES, VALVES, AND RAILS TO BE INSTALLED BY OTHERS. 8.5" III III INV OUT: 696.00' 6" MIN CONCRETE BASE 03" PVC MIN. DRAIN SLOPE TO WET WELL, \-- GROUT SLOPES TO DRAIN MIN 2" THICKNESS PIPE SUPPORT (TYP) MIN 6" CLASS #57 CRUSHED STONE 3" FLAP VALVE 3" DRAIN WITH TRAP AND TRAP GUARD LOW*] GENERAL NOTE 1. UNLESS 01 SHALL BE 2. UNLESS 01 FASTENER' ANCHORS. 3. ALL PUMP: CONTROLf 4. ALL PIPE IN WITH PR01 -ANVIL FIG. 264 (GALVANIZED) OR APPROVED EQUAL 4" O GALV. STD. PIPE KEI 1. 2. 3. 4. (4)-5/8"0 CIP OR EPDXY ANCHORS (DRILLED & SET IN 6" EPDXY) 5. GALV. BASE PL 5/8x9" SQ. PIPE SUPPORT, SEE DETAIL 6/01 D-04 SST INTERMEDIATE GUIDE RAIL SUPPORT (TYP) MONOLITHIC CONCRETE BASE EMERGENCY BYPASS HATCH, SEE DETAIL 5 —EMERGENCY BYPASS LOCATE WIRE FOR FORCE MAIN TO EXTEND INSIDE VALVE PIT, 6" MIN ti HERWISE SPECIFIED, ALL HARDWARE 316 STAINLESS STEEL OR BETTER. HERWISE SPECIFIED, ALL CONCRETE i TO BE 316 STAINLESS STEEL WEDGE , PIPE, VALVES, GUIDE RAILS AND OTHER 'ANEL TO BE INSTALLED BY OTHERS. WET WELL AND VALVE VAULT TO BE DIP ECTO 401. NOTES: O CONCRETE FILLET IN BOTTOM OF WET WELL. SEE DETAIL 2. ONE PIECE, SCHEDULE 40,316 STAINLESS STEEL GUIDE RAILS. DIAMETER PER MANUFACTURER RECOMMENDATIONS. TWO PIECE RAILS WITH INTERMEDIATE (MID') SUPPORT, FOR LENGTHS GREATER THAN 18 FEET. PUMP REMOVABLE CHAIN AND RELATED LIFTING HARDWARE TO BE $" MINIMUM 316L STAINLESS STEEL 2000 LB MINIMUM WORKLOAD LIMIT. LENGTH TO EXTEND 4' ABOVE HATCH. ACCESS HATCHES SHALL BE PAD LOCKABLE FRAME AND COVER WITH FALL PROTECTION GRATING, HALLIDAY PRODUCT HW SERIES OR EQUAL. MINIMUM ONE PUMP DISCHARGE SUPPORT BRACKET FOR DUCTILE IRON PIPE REQUIRED MIDWAY FOR LENGTHS GREATER THAN 10'. 4' X 4' X 6" (MIN) CONCRETE WASH PAD WITH 2" LIP. SLOPE TO DRAIN AND PROVIDE WIRE MESH REINFORCEMENT (WWF 6 X 6, W2.9 X W2.9, WWR CENTER). HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1200 Charlotte, NC 28202-2075 704.338.6700 N.C.B.E.L.S. License Number F-0116