WQ0044093_Toyota_802_Lift_Station_Phase_II_Asbuilts_20240624
CITY OF GREENSBORO WATER RESOURCES DEPARTMENT I I - rE 8 HASE CONSTRUCTION COMPLETE PLEASANT ti�gy a GARDEN .7 �oP Q � ~ � 9�0 HASE III Q PROJECT } EXTENTS a M U rod' 1� N.c HIGHWA 6 `R �G J U LIAN � I HASE II UNDER CONSTRUCTION PRO V ENCE F U T U R CH RCH A N DESIGN � PUMP r STATION i PROJECT��. c, SITE l F_ LOCATION MAP N.T.S. ENGINEERING DIVISION Contract Drawings For City of Greensboro Me asmite Water Water and Sewer Improvements Phase II Civil Greensboro Project No. P05805D Greensboro Contract No. 2022-0180 HDR Project No. 10328289 Greensboro, April 2023 North Carolina WATER...........................................................L.F. _$..0 .................................. SEWER...... 10,950..........................................L.F. _$..0 .................................. RDWY.............................................................L.F. =$..0 ................................... TOTAL.............................................................................................$ ..................................... ❑ ROADWAY TO BE PRIVATELY INSPECTED DATE FEES (S) RECEIVED BY CITY OF GREENSBORO................................................... GENERAL NOTES ALL CONSTRUCTION SHALL CONFORM TO THE MOST CURRENT CITY OF GREENSBORO STANDARDS AND SPECIFICATIONS, ALL NC-DENR REGULATIONS AND ALL REQUIREMENTS FROM THE NORTH CAROLINA DEPARTMENT OF TRANSPORTATION'S POLICIES AND PROCEDURES FOR ACCOMMODATING UTILITIES ON HIGHWAY RIGHTS -OF -WAY. CONSTRUCTION SHALL COMPLY WITH ALL REQUIREMENTS SET FORTH IN ALL PERMITS RECEIVED FOR THE PROJECT, WHICH ARE INCLUDED IN THE CONTRACT SPECIFICATIONS. FOR REQUIREMENTS REGARDING UNDERGROUND UTILITIES, REFER TO "PROTECTION OF EXISTING UTILITIES" LOCATED IN THE SPECIFICATIONS UNDER "PROJECT SPECIAL PROVISIONS." DITCHES DISTURBED BY CONSTRUCTION SHALL BE SEEDED AND LINED WITH APPROPRIATE LINING TO PREVENT SOIL EROSION. SEE NOTES ON SEPARATE SHEETS. GROUND COVER MUST BE PROVIDED FOR DISTURBED AREAS AFTER EVERY 1,000 FEET OF LINE CONSTRUCTION AND AT NO TIME SHALL DISTURBED AREAS BE EXPOSED FOR MORE THAN 15 WORKING DAYS. ALL ENCASED PIPE SHALL BE RESTRAINED JOINT UNLESS OTHERWISE NOTED ON DRAWINGS OR IN SPECIFICATIONS. SEDIMENT MUST BE REMOVED FROM STREETS AS OFTEN AS NECESSARY TO PREVENT ANY BUILD-UP AND TO PREVENT WASHING OF SEDIMENT OUT OF CONSTRUCTION AREAS. DE -WATERING OF STRUCTURES WITH SEDIMENT -LADEN WATER DIRECTLY TO STREAMS IS PROHIBITED. CONTRACTOR SHALL DISPOSE OF ALL DEMOLISHED TANKS, PIPING AND APPURTENANCES AT AN APPROPRIATE OFF -SITE FACILITY. HDR Engineering, Inc. of the Carolinas N.C.B.E.L.S. License No. F-0116 440 S. Church St., Suite 1200 Charlotte, NC 28202 704.338.6700 CONTRACT SHEET 1 OF 20 BEFORE YOU DIG! CONTACT O 1-800-632-4949 STANDARD TOPO SYMBOLS CITY OF GREENSBORO WATER RESOURCES DEPARTMENT Existing Manhole 1/8" (labeled) ............................ 0 Proposed Manhole 1/8"....................................... Telecommunications Manhole 1/8" (labeled) .................. 0 Exist. Curb Inlet 5/32"-5/64................................ Prop. Curb Inlet 5/32"-5/64................................. m Telephone Booth 3/16"-5/16.................................. ❑Q Exist. Telephone Or Power Pole 3/32"........................ Prop. Telephone Or Power Pole 3/32"......................... City Of Greensboro Signal Pole 3/32" (labeled) .............. ® Coo Guy Wire 3/32".............................................. v Exist. Hydrant 3/32"........................................ 0 Prop. Hydrant 3/32"......................................... AK Water Valve 3/32" (labeled) ................................. Traffic Engineering Signal Box 5/64"........................ ❑ coo Gas Valve 3/32"............................................. Grate or Drop Inlet (D.I.) 3/32............................. Right Of Way Monument 3/32"................................. 0 Iron Pipe 3/64.............................................. C OP Meter 5/64"................................................. Electrical Outlet 5/64" (labeled) ........................... Telecommunications Box Or Pedestal 5/64" (labeled)......... ❑T Exist. Precise Traverse Point 7/64" (labeled) ............... P,P 18" Or Less Tree 1/4" (labeled) ............................. 10' Over 20" Tree 5/16" (labeled) ............................... zo° Shrub 5/32.................................................. Clean Out 1 /16"-1 /32" (labeled) ............................ Mao. Light Pole 3/32" (labeled) .................................. ® L!CT Wheelchair Ramp (City Of Greensboro Std. #418).............. wca Control Of Access Line 5/16................................. � Exist. Water Line (labeled) ................................. W Prop. Water Line (labeled) .................................. W Exist. Sanitary Sewer (labeled) ............................. —SS Prop. Sanitary Sewer (labeled) .............................. �• Exist. Right Of Way ......................................... — - - — Proposed Margin ............................................. — - - — Easement (labeled) .......................................... Temporary Construction Easement ............................. E Exist. Dirt Street .......................................... Exist. Pavment.............................................. ---v--v- Exist. Curb (labeled) ....................................... ---------- Exist. Curb & Gutter (labeled) .............................. ---------- Prop. Curb & Gutter (shaded & labeled) ...................... o Survey Line ................................................. SlopeLine .................................................. - Center Line ................................................. — - — Exist. Storm Sewer (labeled) ................................ Prop. Storm Sewer (labeled) ................................. Gas Line (labeled) .......................................... Transmission Line & Tower ................................... E 0 Underground Telecommunication Cable (labeled) .............. T Underground Power Line ...................................... P Fence(labeled) ............................................. X Railroad.................................................... Bridge (Prop. Solid & Exist. Broken) ........................ Box Culvert (Prop. Solid & Exist. Broken) ................... GuardRail .................................................. Hedges Or Bushes (labeled) .................................. WoodsLine .................................................. Exist. House ................................................ i-Seo 2ooi Temporary Silt Fence ........................................ Erosion Control Device (COG Std. No. 215 & 432)............. ^ Cleanwater Diversion Ditch —TD — HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1200 Charlotte, NC 28202-2075 704.338.6700 XITOWER NEAR CABIN WATER TANK SITE L--- BUILDING 801 XCELL TOWER kEAR 4-21 BUILDING 802 0 BUILDING 803 30 All '2 : 1:: 1: : :... 1] - — -- — -- — -- — -- — -- — -- — -- — -- — -- — -- — S HIDIR Engineering, Inc. of the Carolinas NCIBELS License No. F-01 16 440 S. Church St., Suite 1200 Charlotte, NC 28202-2075 704 338.6700 INDEX OF DRAWINGS GENERAL PROJECT NOTES CONSTRUCTION SEQUENCE GENERAL 1. CONTRACTOR SHALL PROVIDE SEQUENCING PLAN/PHASING PLAN PRIOR TO 1. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR SITE SAFETY ASSOCIATED WITH THE WORK UNDER THIS CONSTRUCTION. PROJECT AND FOR COMPLIANCE WITH ALL FEDERAL, STATE, AND LOCAL HEALTH AND SAFETY LAWS, CODES, 1 OOG-00 COVER SHEET REGULATIONS, AND ORDINANCES INCLUDING BUT NOT LIMITED TO THOSE CURRENTLY MANDATED BY THE 2. OBTAIN AND MAINTAIN ON SITE THE LAND DISTURBING PERMIT FROM NCDEQ. 2 OOG-01 ORIENTATION PLAN OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA). 3. NOTIFY THE NCDEQ AT LEAST 48 HOURS PRIOR TO BEGINNING WORK. 3 OOG-02 SITE LAYOUT 4 OOG-03 SHEET INDEX AND GENERAL NOTES 2. CONTRACTOR SHALL USE ADEQUATE SHORING METHODS TO ENSURE: 4. HOLD PRE -CONSTRUCTION MEETING. 5 OOG-04 ABBREVIATIONS AND GENERAL SYMBOLS A. COMPLIANCE WITH OSHA REGULATIONS. 5. INSTALL CONSTRUCTION ENTRANCES TO EDGE OF PAVEMENT OR GRAVEL. B. PROTECTION OF EXISTING PAVEMENT AND ROAD SHOULDERS. FORCEMAIN PHASE 2 C. CONSTRUCTION ACTIVITIES ARE CONFINED TO RIGHTS -OF -WAY OR EASEMENTS AS INDICATED. 6. INSTALL ALL EROSION & SEDIMENT CONTROL MEASURES AS SHOWN ON THE PLANS PRIOR TO ANY SITE DISTURBANCE ACTIVITIES (CLEARING, GRUBBING, GRADING, OR 6 02C-01 MEGASITE FORCE MAIN #1 - PLAN AND PROFILE - STA 12+00 TO 21 +00 3. CONTRACTOR SHALL INSTALL SANITARY FORCE MAINS AND GRAVITY SEWER AS INDICATED ON PLANS AND EXCAVATION). 7 02C-02 MEGASITE FORCE MAIN #1 - PLAN AND PROFILE - STA 21 +00 TO 30+00 SHALL NOT DISTURB ANY AREA OUTSIDE THE EASEMENT LIMITS AND LIMITS OF DISTURBANCE SHOWN ON 7. ALL CLEARING AND GRUBBING ARE TO STAY WITHIN LIMITS AS SHOWN ON THE PLANS. 8 02C-03 MEGASITE FORCE MAIN #1 - PLAN AND PROFILE - STA 30+00 TO 39+00 THE PLANS. 9 02C-04 MEGASITE FORCE MAIN #1 - PLAN AND PROFILE - STA 39+00 TO 48+00 8. AS NOTED ON THE PLANS, NO WORK SHALL BE DONE IN AREAS OF WETLANDS AND 10 02C-05 MEGASITE FORCE MAIN #1 - PLAN AND PROFILE - STA 48+00 TO 57+00 4. CONTRACTOR IS RESPONSIBLE FOR REPAIR/REPLACEMENT OF ALL MAINTAINED PAVEMENT DAMAGED BY STREAMS UNTIL THE 401/404 PERMITS ARE OBTAINED. 11 02C-06 MEGASITE FORCE MAIN #1 - PLAN AND PROFILE - STA 57+00 TO 66+00 CONSTRUCTION ACTIVITIES TO SATISFACTION OF NCDOT, GUILFORD COUNTY, RANDOLPH COUNTY AND THE 9. IN WORK ZONE AREAS: 12 02C-07 MEGASITE FORCE MAIN #1 - PLAN AND PROFILE - STA 66+00 TO 75+00 CITY OF GREENSBORO. NO SEPARATE PAYMENT SHALL BE MADE FOR PAVEMENT REPAIR EXCEPT AS NOTED 13 02C-08 MEGASITE FORCE MAIN #1 - PLAN AND PROFILE - STA 75+00 TO 84+50 ON PLANS. 9.1. INSTALL SILT FENCE AND DOWNSTREAM EROSION CONTROL MEASURES. ENSURE THAT 14 02C-09 MEGASITE FORCE MAIN #1 - PLAN AND PROFILE - STA 84+50 TO 93+00 PRIOR WORK AREA IS CLOSED, SEEDED AND MATTED (IF CALLED OUT ON THE 5. LOCATION OF EXISTING UTILITIES SHOWN ON THESE PLANS ARE NOT INTENDED TO BE EXACT OR PLANS). 15 02C-10 MEGASITE FORCE MAIN #1 - PLAN AND PROFILE - STA 93+00 TO 102+00 COMPLETE. THE CONTRACTOR SHALL COORDINATE WITH ALL UTILITY COMPANIES AND FIELD VERIFY THE 9.2. CONTRACTOR SHALL ESTABLISH CLEAN WATER DIVERSION SWALES AS DETAILED 16 02C-11 MEGASITE FORCE MAIN #1 - PLAN AND PROFILE - STA 102+00 TO 109+05.02 LOCATION AND DEPTH OF ALL UTILITIES PRIOR TO CONSTRUCTION. LOCATE WELL AHEAD OF PIPE LAYING UPSLOPE OF TRENCH LOCATION WHERE ROOM EXISTS BETWEEN LOD AND PROPOSED 05E-04 PHASE V SANDY CREEK OUTFALL - EROSION AND SEDIMENT CONTROL OPERATIONS TO ALLOW FOR ADJUSTMENT. NO SEPARATE PAYMENT WILL BE MADE FOR FIELD VERIFICATION WATERLINE. 05E-05 PHASE V SANDY CREEK OUTFALL - EROSION AND SEDIMENT CONTROL OR ADJUSTMENT AS REQUIRED. ADJUSTMENTS TO LAYOUT SHOWN SHALL BE SUBJECT TO ENGINEER APPROVAL. CONTRACTOR SHALL REPAIR, AT HIS OWN EXPENSE, ANY DAMAGE CAUSED BY 9.3. CONTRACTOR SHALL NOT OPEN UP ANY MORE TRENCH THAN CAN BE CLOSED AT DETAILS CONSTRUCTION -RELATED ACTIVITIES TO EXISTING UTILITY LINES. THE END OF THE DAY. 9.4. SET EXCAVATED MATERIAL ON THE HIGH SIDE OF THE TRENCH SO THAT TRENCH 17 CIVIL DETAILS 6. IN THE EVENT OF DAMAGE TO EXISTING UTILITIES, OR OTHER FACILITIES, CONTRACTOR SHALL STOP WORK WILL ACT AS A BASIN SHOULD THERE BE A POP-UP STORM. 18 CIVIL DETAILS IMMEDIATELY, TAKE NECESSARY PRECAUTIONS TO PREVENT INJURY OR FURTHER DAMAGE, AND NOTIFY 9.5. WORK WITH DRIVEWAYS, EXISTING CULVERTS, ETC. TO REVIEW IN THE FIELD 19 CIVIL DETAILS PROPER AUTHORITIES. CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING/REPAIRING ALL EXISTING LOCATIONS WHERE SEDIMENT LADEN RUN-OFF MAY ESCAPE. PROVIDE EXTRA 20 CIVIL DETAILS STRUCTURES, CONDUITS, OR OTHER UTILITIES DAMAGED BY CONTRACTOR'S OPERATIONS AT NO COST TO MEASURES AS NECESSARY TO MAINTAIN A SEDIMENT SECURE SITE. OWNER. 9.6. APPLY STABILIZATION MEASURES AS SOON AS PIPE IS SET AND TRENCH BACKFILLED AND COMPACTED. 7. THE CONTRACTOR SHALL RECONSTRUCT ALL ROAD SHOULDERS, DRAINAGE DITCHES AND SWALES DISTURBED 9.7. IT IS RECOMMENDED THAT, GIVEN MOST LOCATIONS ARE WITHIN OR NEAR ROADSIDE BY CONSTRUCTION ACTIVITIES TO THEIR ORIGINAL GRADE AND LOCATION. DITCHES THAT SEEDING OCCUR WITHIN 7 DAYS OF OPENING DISTURBED AREAS. 9.8. WORK WITH THE NCDEQ INSPECTOR ON THE USE OF WATTLES VERSUS ROCK CHECK 8. ALL HOLES, TRENCHES, AND OTHER HAZARDOUS AREAS SHALL BE ADEQUATELY PROTECTED BY DAMS AT VARIOUS LOCATIONS. BARRICADES, LIGHTS OR OTHER PROTECTIVE DEVICES. 10. INSPECT ALL EROSION CONTROL DEVICES AT WEEKLY INTERVALS AND AFTER EVERY 9. REMOVAL OF EXCAVATED MATERIALS AND DAILY CLEANUP OPERATIONS SHALL BE PERFORMED IN RAINFALL EVENT EXCEEDING 1.0 INCH TO VERIFY THAT THEY ARE FUNCTIONING COMPLIANCE WITH THE SPECIFICATIONS AND TO THE SATISFACTION OF THE OWNER/ENGINEER, AND/OR PROPERLY. ANY ACCUMULATED SEDIMENT SHALL BE REMOVED AND PLACED IN A NCDOT. DESIGNATED SPOIL DISPOSAL AREA APPROVED BY THE INSPECTOR. CONDUCT PERIODIC INSPECTIONS OF ALL EROSION AND SEDIMENTATION CONTROLS AND MAKE ANY REPAIRS 10. ALL ROCKS, BRUSH, TIMBER, AND OTHER DEBRIS THAT IS CLEARED FROM THE RIGHTS -OF -WAY SHALL BE OR MODIFICATIONS NECESSARY TO ASSURE CONTINUED EFFECTIVE OPERATION OF EACH REMOVED FROM THE PREMISES AND SHALL NOT BE BURIED WITHIN THE RIGHT-OF-WAY OR PLACED ON DEVICE. ADJOINING LANDS, EXCEPT WHERE ARRANGEMENTS FOR SUCH PLACEMENT OR DISPOSAL ARE MADE WITH THE APPROPRIATE PROPERTY OWNERS. 11. BORE LOCATIONS: CLEAR UTILITY MAIN EASEMENTS AND GRUB AREAS FOR BORE PITS, HAUL ALL DEBRIS FROM CLEARING ACTIVITIES TO AN APPROVED OFF -SITE WASTE 11. ALL TREE PROTECTION AND EROSION AND SEDIMENTATION CONTROLS SHALL BE IMPLEMENTED BEFORE HANDLING FACILITY. CONSTRUCTION COMMENCES AND SHALL NOT BE REMOVED UNTIL RE -VEGETATION HAS BEEN ESTABLISHED. 12. THERE ARE AREAS WITHIN THE PROJECT WHERE THERE ARE LARGE DRAINAGE AREAS FLOWING THROUGH THE SITE WITH LIMITED ABILITY TO DIVERT THOSE FLOWS AROUND 12. ANY AGREEMENT BETWEEN THE CONTRACTOR AND PROPERTY OWNERS SHALL BE MADE IN WRITING AND THE WORK ZONE. THESE AREAS ARE NOTED IN THE PLANS AS "SENSITIVE AREAS" AND COPIED TO THE OWNER. THERE RE SPECIFIC CONSTRUCTION SEQUENCES FOR THESE AREAS. 13. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING THE ENGINEER WITH A SET OF SURVEY RECORD 13. AFTER STABILIZATION IS ESTABLISHED, THE CONTRACTOR SHALL WORK WITH NCDEQ TO (AS -BUILT) DRAWINGS PREPARED BY A NORTH CAROLINA REGISTERED LAND SURVEYOR CERTIFYING THE OBTAIN APPROVAL FOR REMOVING EROSION CONTROL BMPSs. ACCURACY OF THE SURVEY HORIZONTAL AND VERTICAL LOCATIONS TO ONE TENTH (0.10) OF A FOOT. SURVEY SHALL BE TIED TO THE NORTH CAROLINA STATE PLANE COORDINATE SYSTEM (NAD83 FEET) HORIZONTALLY, AND ELEVATIONS SHALL BE NORTH AMERICAN VERTICAL DATUM (NAVD88). SURVEY POINT INFORMATIONSHALL BEPROVIDED IN NELECTRONICAUTOCAD [VERSION 2018 OR EARLIER] DWGFILE OR AN ASCIIPOINTTEXT LE FILE COORDINATES]). EROSION EROSION CONTROL NOTES AND SEQUENCES THESE DRAWINGS SHALL AT A MINIMUM SHOW THE FINAL ELEVATIONS AND HORIZONTAL LOCATIONS FOR THE FOLLOWING: ALL MANHOLES, PIPING INVERTS IN MANHOLES, VAULTS, BELOW GRADE FITTINGS, VALVES, ALONG THE - SEE GREENSBORO RANDOLPH MEGASITE FOUNDATION DRAWINGS (PROJECT NUMBER: WATERLINE AND FORCE MAIN. 10068163) FOR EROSION CONTROL CONSTRUCTION SEQUENCE, PLANS, & DETAILS. - FOR SHEETS 02C-09 - 02C-1 1, SEE SHEETS 05E-04 AND 05E-05 ON CITY OF CONTRACTOR SHALL PROVIDE THE ENGINEER WITH A LETTER CERTIFYING TO THEIR COMPLIANCE WITH THE GREENSBORO PHASE V SANDY CREEK OUTFALL (PROJECT NUMBER: 10328292) FOR CONTRACT DRAWINGS. EROSION CONTROL MEASURES OFF OF PAD SITE. 14. CONTRACTOR IS RESPONSIBLE FOR ALL CONSTRUCTION STAKING. 15. NOT ALL TREES OR VEGETATION ARE SHOWN ON DRAWINGS. NO EXTRA PAYMENT WILL BE GIVEN FOR REMOVING TREES NOT SHOWN. REMOVE ALL TREES WITHIN EASEMENT LIMITS. VEGETATION OUTSIDE EASEMENT LIMITS IS NOT TO BE DISTURBED. 16. EXISTING TOPOGRAPHIC SURVEY BASED ON LIDAR DATA. 17. PROPOSED TOPOGRAPHY OBTAINED FROM GREENSBORO RANDOLPH MEGASITE GRADING PLANS (PROJECT NUMBER: 10068163. 18. ALL CLEAN -OUTS AND SERVICE LINES SHALL BE INSTALLED PER NC PLUMBING/INTERNATIONAL PLUMBING CODES (LATEST EDITION) 19. ALL CONSTRUCTION SHALL CONFORM TO CITY OF GREENSBORO/NCDEQ STANDARDS. 20. CITY OF GREENSBORO CONSTRUCTION INSPECTOR REQUIRED FOR WATER AND SANITARY SEWER. CALL (336) 373-2377 TO SCHEDULE INSPECTOR. 21. ALL PIPE LAYING CONDITIONS TO FOLLOW PIPE MANUFACTURER'S RECOMMENDATIONS. 22. ALL DUCTILE IRON FITTINGS AND APPURTENANCES TO HAVE PROTECTO 401 OR APPROVED EQUAL. 23. ALL AIR RELEASE VALVE MANHOLES SHALL BE LINED TO PROTECT FROM SEWER GASES WITH A MINIMUM EPDXY COATING OF 150 MILS. F)l HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1200 Charlotte, NC 28202-2075 704.338.6700 MATERIALS IN PLAN/SECTION GENERAL SYMBOLOGY ABBREVIATIONS A, AMP AMPERE FICA FLANGED COUPLING ADAPTER NF NON —FUSED ARROW INDICATES TARGET ELEVATION @ AT FD FLOOR DRAIN NO NORMALLY OPEN/NUMBER ACOUSTICAL CEILING TILE (SECTION) DIRECTION OF AB ANCHOR BOLT FDN FOUNDATION NOM NOMINAL PLAN NORTH ABC AGGREGATE BASE COURSE FFE FINISHED FLOOR ELEVATION NTS NOT TO SCALE ASPHALT (PLAN OR SMALL—SCALE SECTION) AC ACI ALTERNATING CURRENT AMERICAN CONCRETE INSTITUTE FIN FL, FLR FINISHED FLOOR NPT NS NATIONAL PIPE THREAD NEAR SIDE ARCHITECTURAL ACSR ALUMINUM CABLE STEEL REINFORCED FLA FULL LOAD AMPS CIA OVERALL 4 ASPHALT (LARGE—SCALE SECTION) PLAN 1/4" 1'-0" AD ADD ACCESS DOOR ADDENDUMOD FLG FLOUR FLANGE FLUORESCENT OC,O/C ON CENTER OUTSIDE DIAMETERADDL = ROOM NAME ADDITIONAL F/0 FIBER OPTIC OIT OPERATOR INTERFACE TERMINAL PLAN TITLE ADJ ADJACENT FO FINISHED OPENING/FAIL OPEN OPH OPPOSITE HAND 2M BATT INSULATION (SECTION) XX—XX ROOM NUMBER AF AMP FRAME FOB FLAT ON BOTTOM OPNG OPENING AFF ABOVE FINISHED FLOOR FOT FLAT ON TOP OPP OPPOSITE SECTION LETTER !XXX DOOR NUMBER AFG AGGR ABOVE FINISHED GRADE AGGREGATE FPT FRP FLOOR PLATE FIBER REINFORCED PLASTIC ORP P OXIDATION REDUCTION POTENTIAL PIPE BRICK MASONRY (PLAN AND/OR SECTION) X AHU AIR HANDLING UNIT PB PULL BOX FS FAR SIDE FLAG INDICATES DIRECTION AIC AMPS INTERRUPTION CAPACITY FT FOOT OR FEETFTG PCCP PRESTRESSED CONCRETE CYLINDER PIPE OF SECTION CUT A COLUMN GRID LINE (SYMMETRICAL) FOOTING PCF POUNDS PER CUBIC FOOT CHECKERED PLATE (PLAN) X AL, ALUM ALUMINUM FUT FUTURE PE PLAIN END XXX ALTN ALTERNATE FWD FORWARD PF POWER FACTOR a a a SHEET WHERE SECTION WALL TYPE AMB AMBIENT GA GAGE PH PHASE a CONCRETE (PLAN AND/OR SECTION) IS LOCATED ANDZ ANODIZED GAL GALLONS PL PLATE CONCRETE MASONRY AND/OR SECTION CUT MARKER X WINDOW TYPE O APPR AT APPROXIMATE AMP TRIP GALV GEN GALVANIZED GENERATOR PLC PNL PROGRAMMABLE LOGIC CONTROLLER PANEL (PLAN SECTION) ATM ATMOSPHERE GFCI GROUND FAULT CIRCUIT INTERRUPT PNT PAINT AUTO AUTOMATIC GPM GALLONS PER MINUTE PP POWER POLE SECTION LETTER �X LOUVER AUX AUXILLIARY GND GROUND PROJ PROJECTION DEMOLITION (PLAN AND/OR SECTION) SECTION AVG AVERAGE GV GATE VALVE PROP PROPOSED X AWG AMERICAN WIRE GAGE HC HOLLOW CORE PSC PRESTRESSED CONCRETE °° XXX BET BETWEEN HDW HARDWARE PSF POUNDS PER SQUARE FOOT EARTH (SECTION) — 3/8 — 1 —0 SHEET WHERE OX ACCESSORY, FURNITURE, BF BLIND FLANGE, BOTH FACES, HEX HEXAGONAL PSI POUNDS PER SQUARE INCH SECTION VIEW IS AND MISCELLANEOUS BOTTOM FACE HH HANDHOLE PSIG POUNDS PER SQUARE INCH GAUGE FIRST CUT * EQUIPMENT IDENTIFIER BLDG BUILDING HID HIGH INTENSITY DISCHARGE PT POINT, POINT OF TANGENCY FILTER POINT MAT (PLAN) BLK BLOCK HK HOOK PUE PUBLIC UTILITY EASEMENT SECTION TITLE BLKG BLOCKING HM HOLLOW METAL PVC POLYVINYL CHLORIDE KEY NOTE DESIGNATION BM BENCH MARK HOA HAND —OFF —AUTOMATIC PVMT PAVEMENT FINISHED WOOD (SECTION) BOP BOTTOM OF PIPE HOAR HAND —OFF —AUTOMATIC —REMOTE PWR POWER BOT OR B/ BOTTOM HORIZ HORIZONTAL P/LF POUNDS PER LINEAL FOOT GLULAM LUMBER (SECTION) DETAIL NUMBER # KEY NOTE NUMBER # BP BRIG BASE PLATE BEARING HP HPS HORSEPOWER, HIGH POINT, HEAT PUMP HIGH PRESSURE SODIUM RAID RED RADIUS REDUCER BRGPL BEARING PLATE HPT HIGH POINT REF REFERENCE XXX SHEET WHERE DETAIL BS BOTH SIDES HSB HIGH STRENGTH BOLT REINF REINFORCED, REINFORCING GRANULAR FILL (SECTION) IS LOCATED BTU BRITISH THERMAL UNIT HT HEIGHT REQD REQUIRED BV BALL VALVE HV HIGH VOLTAGE REV REVISED, REVISION DETAIL MARKER C CONDUIT HVAC HEATING, VENTILATING AND AIR CONDITIONING RGS RIGID GALVANIZED STEEL CONDUIT GENERAL LINE SYMBOLOGY GRATING (SECTION) FOR REFERENCING DETAILS INCLUDED IN DRAWING SET. CB C/C CATCH ASIN CENTER BTO CENTER HWL HWR VEL HIGH AWATERTER E RETURN HEATED RH RJ RIGHT HAND RESTRAINED JOINT CFM CUBIC FEET PER MINUTE HWS HEATED WATER SUPPLY RL ROOF LOAD GRATING (PLAN) XXXXXXXXX CHWR CHILLED WATER RETURN HZ HERTZ RLA RUNNING LOAD AMPS CHWS CHILLED WATER SUPPLY ID INSIDE DIAMETER RM ROOM DETAIL MARKER 4—HOUR FIRE RATED WALL CIR CIRCUMFERENCE IE INVERT ELEVATION RO ROUGH OPENING .. GROUT (SECTION) CJ CONSTRUCTION JOINT IG ISOLATED GROUND ROW RIGHT OF WAY ° FOR REFERENCING DETAILS BOUND IN CKT CIRCUIT IN INCHES RTU REMOTE TERMINAL UNIT SPECIFICATIONS OR SEPARATE VOLUME. 3—HOUR FIRE RATED WALL CLG CEILING INC INCLUDING RVAT REDUCE VOLTAGE AUTO TRANSFORMER GYPSUM BOARD (SECTION) CLKG CAULKING INFO INFORMATION RVSS REDUCED VOLTAGE SOLID STATE CLR CLEAR INSTL INSTALL, INSTALLATION R/W RIGHT OF WAY METAL (SECTION) DETAIL NUMBER DETAIL 2—HOUR FIRE RATED WALL CO COM CLEANOUT COMMON INSUL INTR INSULATION INTERIOR OR INTERMEDIATE RPZ S BACKFLOW PREVENTOR SOUTH # INTRINSIC SAFETY BARRIER SCH SCHEDULE 1 —HOUR FIRE RATED WALL COMB COMBINATION ISB 3" = 1'-0" XXX CONIC CONCRETE ISDPS INFLUENT STRUCTURE DRAIN PUMPING STATION SECT SECTION ORIENTED STRAND BOARD (SECTION) SHEET WHERE DETAIL CONN CONNECTION JB JUNCTION BOX SHT SHEET WAS CALLED OUT * COLUMN GRID LINE/CENTERLINE CONT CONTINUOUS J, JCT JUNCTION SIG SIGNAL CONTR CONTRACTOR JF JOINT FILLER SIM SIMILAR PARTICLE BOARD (SECTION) CPLG COUPLING JT JOINT SPD SURGE PROTECTION DEVICE DETAIL TITLE IDENTIFICATION SYMBOLOGY CRS COUNTERSINK K KIP SPEC SQ SPECIFICATION SQUARE PLYWOOD (LARGE—SCALE SECTION) ELEVATION NUMBER CT CTD CURRENT TRANSFORMER CENTER, CENTERED KCMIL kV 1000 CIRCULAR MILLS KILOVOLTS SS,STANDARD STAINLESS STEEL STD PIPING CTL CONTROL JOINT kVA KILOVOLT AMPERES STANDARD ARROW INDICATES X POINT OF VIEW CTR CENTER kW KILOWATT STL STEEL PLYWOOD (SMALL—SCALE SECTION) XX FIGURE 36—PLE EXAMPLE CTRL CUFT CONTROL CUBIC FOOT LA LIGHTING ARRESTOR STRL SUSP STRUCTURAL SUSPEND SHEET WHERE ELEVATION LBS POUNDS a a PRECAST CONCRETE (PLAN AND/OR IS LOCATED * CUYD DC CUBIC YARD DIRECT CURRENT LC LF LOCKED CLOSED LINEAR FEET SW SYM STILLING WELL SYMMETRICAL SECTION) SINGLE ELEVATION OR PHOTO MARKER LINE SIZE 36" DCJ DOWELED CONTROL JOINT LG LONG SYS SYSTEM RIGID INSULATION (SECTION) SERVICE PLANT EFFLUENT DE DEM DRAINAGE EASEMENT DEMOLITION LH LL LEFT HAND LIVE LOAD TC TCE TOP OF CURB TEMPORARY CONSTRUCTION EASEMENT A ELEVATION NUMBER DET DETAIL LO LOCKED OPEN T&B TOP AND BOTTOM r'D'_4'Xn RIPRAP (PLAN AND/OR SECTION) ARROW INDICATES POINT OF EQUIPMENT IDENTIFICATION DI DIA DUCTILE IRON DIAMETER LOC'N LOD LOCATION LIMITS OF DISTURBANCE TEMP TERM TEMPERATURE TERMINAL VIEW ELEVATION DIAG DIAGONAL LP LOW POINT, LIGHTING PANEL THK TH / THICK D B DIM DIMENSION LR LONG RADIUS TO OR T/ TOP OF X X INDICATES SHEET WHERE ALTERNATIVE 1 DIP DUCTILE IRON PIPE LTG LIGHTING TOC OR T/CONC TOP OF CONCRETE SAND (SECTION) ELEVATION IS LOCATED NPWP2023 DISC DISCONNECT LTS LIGHTS TOG TOP OF GRATING FIGURE EXAMPLE DUE DRAINAGE MAINTENANCE UTILITY EASEMENT LV LOW VOLTAGE TOS OR T/STL TOP OF STEEL (1 C MULTIPLE ELEVATION OR PHOTO MARKER DN DO DOWN DISSOLVED OXYGEN LWL LOW WATER LEVEL TOW OR T/WALL TP TOP OF WALL TURNING POINT SOD (SECTION) SERVICE INDICATES MAN MANUAL \1�1IIV� ABBREVIATION NON —POTABLE WATER DWG IL G L MATERIAL TRD TREAD WEEP JOINT MORTAR ELEVATION DWL DOWEL MAX MAXIMUM I TS TEMPERATURE SWITCH PROTECTION SYSTEM (SECTION) IDENTIFICATION EQUIPMENT INDICATES PUMP E EA EAST EACH MB MACHINE BOLT TSP TYP TWISTED SHIELDED PAIR TYPICAL NUMBER ABBREVIATION MBH THOUSAND BTU'S PER HOUR ELEVATION BUILDING OR EF EACH FACE, EXHAUST FAN MBR MEMBER UE UNDERGROUND ELECTRICAL ® (SECTION) WOOD — CONTINUOUS SECTION X STRUCTURE BUILDING 20 EJ EXPANSION JOINT MCA MAXIMUM CONTINUOUS AMPS UG UNDERGROUND 3" = 1 —0 XXX NUMBER EJF EXPANSION JOINT FILLER MCC MOTOR CONTROL CENTER UON,UNO UNLESS OTHERWISE NOTED WOOD BLOCKING (SECTION) SHEET WHERE POINT EL, ELEV ELEVATION MCCB MOLDED CASE CIRCUIT BREAKER V VOLT OF VIEW MARKER CAN EQUIPMENT PUMP 23 NUMBER ELEC ELL ELECTRICAL ELBOW MCOP MAXIMUM OVER CURRENT PROTECTION VA VB VOLT AMPERE VAPOR BARRIER BE FOUND * EMBED EMBEDMENT MECH MECHANICAL VALVE BOX GENERAL NOTES: ELEVATION TITLE ALTERNATIVE 2 ENCL ENCLOSURE MET MFR METAL MANUFACTURER BT VR VERTICALX NPWP-23 EOP EPS EDGE OF PAVEMENT EFFLUENT PUMPING STATION MH MANHOLE, METAL HALIDE VE VARIABLE FREQUENCY DRIVE 1. THIS IS A STANDARD SHEET SHOWING COMMON * EXCEPTIONS WHERE THE SHEET NUMBER IS REPLACED BY A FIGURE EXAMPLE EQ EQUAL MIN MINIMUM W WATTS/WEST/WIRE SYMBOLOGY. ALL SYMBOLS ARE NOT NECESSARILY DASH (—). EQUIP EQUIPMENT MISC MISCELLANEOUS WL WATER LEVEL USED ON THIS PROJECT. 1) FOR COMMON DETAILS, SECTIONS, ELEVATIONS OR DETAILS SERVICE INDICATES ETM ELAPSE TIME METER MJ MECHANICAL JOINT WM WIRE MESH THAT ARE CUT OR CALLED OUT ON MULTIPLE SHEETS. ABBREVIATION NON —POTABLE WATER EW EACH WAY MO MASONRY OPENING P W/ WEATHERPROOF 2. SCREENING OR SHADING OF WORK IS USED TO 2) SECTIONS, ELEVATIONS OR DETAILS THAT ARE LOCATED ON EQUIPMENT EX EXISTING MTD MOUNTED W WITH INDICATE EXISTING COMPONENTS OR TO INDICATES PUMP MTG MOUNTING W 0 / WITHOUT DE—EMPHASIZE PROPOSED IMPROVEMENTS TO THE SAME SHEET THEY ARE CUT OR CALLED OUT ON. ABBREVIATION EXIST EXISTING N NORTH, NEUTRAL YD YARD HIGHLIGHT SELECTED TRADE WORK. REFER TO EQUIPMENT EXP EXPANSION NC NORMALLY CLOSED YH YARD HYDRANT CONTEXT OF EACH SHEET FOR USAGE. NUMBER PUMP 23 EXPO EXPOSED ND NORMALLY DE —ENERGIZED Z/C TS Z CONDUCTOR TWISTED SHIELDED CABLE EXT °F EXTERIOR NEC NORMALLY ENERGIZED 2/C TS 2 CONDUCTOR TWISTED SHIELDED CABLE FAHRENHEIT NE NATIONAL ELECTRIC CODE 3/C TS 3 CONDUCTOR TWISTED SHIELDED CABLE FA FC FOUL AIR FAIL CLOSED NEUT NEUTRAL DIMENSION TO BE VERIFIED WITH OR AS REQUIRED * FOR PURCHASED ITEM SENSITIVE INFORMATION Not to be copied or distributed without the express written permission of the City of Greensboro. ��� www.ncimtorg CHY COG Water GDOT Traffi COG/GuiIf COG Wat�r Tanks � GDOT St rn NPDES General Permit Applies DISTURBED AREA OFF PAD = 2.11 AC :!0 [ N1][•YyW_\I711a:N Objects on this map shown with a dotted linestyle were not surveyed, they were compiled by photogrammetric methods, available on the Geographic Information System (GIS) software used by the City of Greensboro. F)l HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1200 Charlotte, NC 28202-2075 704.338.6700 LOCATION MAP MATCH LINE STA 21+00 I I I IIII 2135 I I I 683.50 II I IIII dot N sleeve I I I N 781252.1 E 1812548.0 ce - -� / �� - 10" GATE VALVE m c L STA 19+40 I v + I _ N 781264.86 1 a' I E 1812401.66 0 0 9.67 ,I 1 10" X 6" WYE WITH 6" GATE VALVE FOR FUTURE CONNECTION BY TOYOTA STA 19+33 / N 781265.56 \ \ \ \ E 1812393.76 2112CD O O O O O E) E) � O O O E)O O 161NC ©\ 0 1 0 0 1 0 0 0 O O O O O 0 0 10 t o o l 0 0 C:) 0 0 61N CASING \\ \ \ \ I N 781273.7 \\ \ \ \ \ O O X O O X O I O X O O X O O X01 22.5' BEND (HORIZONTAL) E)X O 0 0 E 1812301.0STA 16+11 \ \1 1 I N 781407.79 \ \ \ \ \ , �\ E 1812168.70 68 LF OF 16" STEEL CASING BY OPEN CUT MIN. THICKNESS 0.250" I I I - � _ I 3005 I - I 1 692.29 2104 1 I I I I I _ _ TOP RIM ARV I IT m - - 5003 N 781466.1 680.58 I I I I I I I m - - - - - - - - SING 683.44 E 1812174.0 1 \ N78 325.4 I I � I � 0 J 10" C-900 DR-18 PVC PIPE APPROXIMATE LOCATION OF 803 LIFT STATION AND FORCE MAIN, TO BE BUILT BY OTHERS 8" X 10" REDUCER (CONCENTRIC) STA 18+52 N 781272.55 E 1812313.71 2111 683.84 161N CASING N 781279.3 E 1812233.0 22.5' BEND (HORIZONTAL) STA 17+42 • N 781282.13 E 1812204.24 _ 2109 �y • 682.94 81N 45 BEND FM ' N 781283.5 t E 1812201.0 D _ O cn �� - 81N SLEEVE FM _ N 781559.0 - �(� _ �l \ 1 I E 1812191.0 I I I I I I + 8 C-900 DR-18 PVC PIPE _ - �� I I I- •., MM m -_ �_ E 1812182.0 _ � I I I I I I 'jx .. � , 45 BEND (HORIZONTAL) m - I 1 I I I I • STA 17+39 _ I I I I I •, • ' • ., • o N 781283.78 cn m � = D ----L ----T--- - - - - -- �13+QQ I - � � �4+00 ,� 1 1 +0oI, 16k I ..• . j• .•. • � •, I E 1812201.05 o _ __ ��� 1 1 50 ••• ' j '' I '• 2110 cDn T m T\T RIZONTAL) \ \ 730 720 710 700 M 670 - � V COMBINATION AIR RELEASE i VALVE AND MANHOLE Is OP SEE DETAIL 211/02D-03 \ / STA 15+50 � �I r N7o 1468- 781466.1 II E 1812174 1812174 12+00 12+50 13+00 13+50 14+00 14+50 15+00 HDR Engineering, Inc. REVISIONS of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1200 I Charlotte, NC 28202-2075 704.338.6700 ■ x z x FINAL DESIGN 5005 +� 681.54 ' ' 682.81 �• 81N 22.5 BEND FM 2105 N 7 22 8 BEND FM III I N 781413.0 J 683.23 , I N 781281.5 \ E 1812170.0 CASING E 1812204.0 •.. • N 781285.E � \ \ I I I 0 I4' I I I \ E 1812200.0 \ \ \ 8" GATE VALVE I I \ \ STA 15+59 81N FM VALVE NUT I \ N 781459.40 I I N 781459.4 I 0 \ 41 LF OF 16" STEEL CASING BY OPEN CUT E 1812173.11 I I I I I I I E 1812174.0 ° MIN. THICKNESS 0.250" yy I IIIIIIII. I �,1111 I _ ° II 15+50 16+00 TYPE ROADWAY SEWER WATER SIDEWALK 16+50 17+00 17+50 18+00 18+50 19+00 CONTRACT ICONTRACTORI AS -BUILT I AUTH. DATE I WATER AND SEWER PERMITS 2022-0180 40 0 40 80 HORIZONTAL SCALE IN FEET 10 0 10 20 VERTICAL SCALE IN FEET 19+50 20+00 20+50 JOB NO. P-05805E-07 DESIGNED 4 2023 BY HDR CONST. SURVEY BY CHECKED BY SCALE: AS NOTED 730 720 710 700 CONTRACT SHEET 6 of 20 SENSITIVE INFORMATION Not to be copied or distributed without the express written permission of the City of Greensboro. North 81 Caroli�na� Clay of reeps1lodro F1nc#er rounc Locato Info 1 /R uests c_ COG Water f�esoya .es 73-2033 GDOT Traffi Si� - Ze _ 73-2606 COG/GuiIf9rd Co. Tcom - 73-2084 COG Water upply _ - - - - - 73-5855 Tanks/Tredtment Plants j GDOT Storm Voter _ - - - / 73-2569 NPDES General Permit Applies DISTURBED AREA OFF PAD = 2.11 AC GIS DISCLAIMER Objects on this map shown with a dotted linestyle were not surveyed, they were compiled by photogrammetric methods, available on the Geographic Information System (GIS) software used by the City of Greensboro. + I K_ I I CITY OF GREENSBORO WATER RESOURCES DEPARTMENT Megasite City of Greensboro Wet Utilities Phase 2 MEGASITE FORCE MAIN #1 PLAN AND PROFILE STA 12+00 TO STA 21 +00 02C- 01 SHEET NO. 6 OF 20 LOCATION MAP EN 710 WIN w d d z FL w m 130Q •M 670 •M Mom co O I` 10" C-900 DR-18 PVC PIPE O 1-00 N 1 21+5 U) w z_ J IU III I I III � I III I II �II I � � % � �;IIIII,I 1 �I 1 II II II II �I II II I I I I III I I KII I I III I i III I I III I I�III I � I I I III II ,� 10" 45' FITTING (HORIZONTAL) STA 28+30 N 781183.27 E 1813285.35 of I II �I + III II N I 2145 I 685.20 I I 10in 45 bend IE 1813285.6 o I 11 II I III 11 I I I I I � I I II I I I NI II I I J I I III111 I � I III I I \ MATCHLINE STA 30+00 9 ----------------- z --- Q w 10" 45° FITTING z L` ON a ,` (HORIZONTAL) STA28+24 00 v 0O a co O + ------ -•`�_ � N Q o = + 6) O (if___ _ _ N Q ````- F3 � Q < z —'---- -- EXISTING GRADE, TYP w _ < z cn w ---------- - - - - - - \ w U)---------------- — 10" C-900 DR-18 PVC PIPE :r — �--_ — 228 LF OF 24" STEEL CASING BY OPEN CUT MIN. THICKNESS 0.250" 105 LF OF 24" STEEL CASING BY OPEN CUT MIN. THICKNESS 0.250" --- '------------ ALL FORCE MAIN PIPE SHALL BE INSTALLED ON A POSITIVE SLOPE OF 0.1% OR GREATER M LO . (O (0 C OR CM O O cl .LO U') C.00 O U') LIDO O M O 00 CV) CIO 0) 0") O CO C.O N .M O 't Co � 0)M N 'IT� �A 0) NO OO 00O L) �O O C7O N O 00 U.)N O M O ON ON O CID CID (0 (O 0) (0 0) (0 m (O co O (0 � O CO 0) � (0 0) (0 a) (0 0) co O O 0) O �M O O 0) O co O W 0)CO � O 21+00 21+50 22+00 22+50 23+00 23+50 24+00 24+50 �� 0 40 80 HORIZONTAL SCALE IN FEET 10 0 10 20 VERTICAL SCALE IN FEET 710 700 ••ff m 670 m MOM O O O c+, 25+00 25+50 26+00 26+50 27+00 27+50 28+00 28+50 29+00 29+50 30+00 K- CONTRACT SHEET 7 of 20 SENSITIVE INFORMATION Not to be copied or distributed without the express written permission of the City of Greensboro. N o rah 8� Caroli�na� Clay of Gree oro ncler rounc Locates Info Juests 7esep COG Water esow 73-2033 GDOT Traffi Si� 73-2606 COG/Guilf rd Co. Telecom — 73-2084 COG Water upply _ _ — — — — 73-5855 Tanks/Treatment Plants GDOT Storm W(ter _ — — — 73-2569 NPDES General Permit Applies DISTURBED AREA OFF PAD = 2.11 AC GIS DISCLAIMER Objects on this map shown with a dotted linestyle were not surveyed, they were compiled by photogrammetric methods, available on the Geographic Information System (GIs) software used by the City of Greensboro. F)l HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1200 Charlotte, NC 28202-2075 704.338.6700 REVISIONS FINAL DESIGN TYPE CONTRACT CONTRACTOR AS —BUILT AUTH. DATE WATER AND SEWER PERMITS JOB NO. P— 05805E-07 CITY OF G R E E N S B O R O WATER RESOURCES DEPARTMENT 0 2 C— 0 2 ROADWAY DESIGNED 4 2023 BY HDR SEWER 2022-0180 CONST. SURVEY BY Megasite City of Greensboro Wet Utilities Phase 2 MEGASITE FORCE MAIN #1 PLAN AND PROFILE STA 24+00 TO STA 36+00 SHEET NO. WATER CHECKED BY 7 OF 20 SIDEWALK SCALE: AS NOTED LOCATION MAP CONTRACT SHEET 8 of 20 W 700 Me .:1 670 Zee1 650 M1 Iq 00 co 011IIIj1' - 17 C-00DR-1 E COMBINATION AIR RELEASE _ 0 VALVE AND MANHOLE - SEE DETAIL 211/02D-03 4+77 / STA 3 57 780540.7 Q 3006 III I III E 1813231.89-1813232 690.88 MIN THICKNESS CKNESS 0 STEEL SING BY OPEN CUT _I - TOP RIM ARV 0 Q N 780540.7 - E 1813232.0 CB / CB CB Ca B CB CB CB CB - co -� - co 00 0 - 33+00 \ z 30+50 31+5� 32+50 / +50 34+50 FNV FM 4- 10" GATE VALVE 2108 1___ � � o STA 34+88 �� 684.96 / 685.39 + N 780527.23 - 101N SLEEVE FMK7=I CASING la- E 1813230.95 _ N 780267.2 I cn E 1813209.0 N 780195.E LU _ E 1813203.0 z - _ 36+00_ �0 - _ 37/ 38+ \ \ _ U 36+� 7+50 _ 38 Q ----- 2149 \ 2148 685.6E 2078 80 LF OF 24" STEEL CASING BY OPEN CUT 685.96 sleeve 686.00 N 780427.4 MIN. THICKNESS 0.250" - 10in gv fm 81N SLEEVE FM N 780527 6 E 1813222.5 N 780759.9 E 1813230.7 _-_ - E 1813250.0 2147 - - :_2686.19 - - - X- X i X- bell restaint megalug - - _ N 780561.0 j E 1813233.6 i 2107 685.48 - 241N CASING - - N 780255.4 E 1813208.0 - z 40 0 40 80 30+50 31+00 31+50 32+00 32+50 33+00 33+50 34+00 34+50 35+00 35+50 36+00 36+50 37+00 37+50 38+00 38+50 700 .:1 670 e 1� M1 co OR ti 00 CD i? 0mil1 HORIZONTAL SCALE IN FEET 10 0 10 20 VERTICAL SCALE IN FEET 111 SENSITIVE INFORMATION Not to be copied or distributed without the express written permission of the City of Greensboro. IWINorth 8� aroli�na� Clay of reepsboro F1nc#er round Locato nfo 1 /Requests COG Water Resgya es ep . 73-2033 GDOT Traffi Sit _ _ _ 73-2606 COG/Guilf�upply rd Co. Telecom _ 73-2084 COG Water _ - - _ - - 73-5855 Tanks/Tredtment Plants j GDOT Storm Water _ - - - 73-2569 �I NPDES General Permit Applies DISTURBED AREA OFF PAD = 2.11 AC GIS DISCLAIMER Objects on this map shown with a dotted linestyle were not surveyed, they were compiled by photogrammetric methods, available on the Geographic Information System (GIS) software used by the City of Greensboro. IM)l HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1200 Charlotte, NC 28202-2075 704.338.6700 REVISIONS TYPE ROADWAY SEWER 1 2 ziWATER FINAL DESIGN SIDEWALK CONTRACT CONTRACTOR AS -BUILT I AUTH. DATE WATER AND SEWER PERMITS 2099-0180 JOB NO. P-05805E-07 CITY OF GREENSBORO WATER RESOURCES DEPARTMENT 02C-03 DESIGNED 4 2023 BY HDR CONST. SURVEY BY Megasite City of Greensboro Wet Utilities Phase 2 MEGASITE FORCE MAIN #1 PLAN AND PROFILE STA 30+00 TO STA 39+00 SHEET NO. CHECKED BY 8 OF 20 SCALE: AS NOTED LOCATION MAP [7 CONTRACT SHEET 9 of 20 700 e .:I 670 W 650 O 39+00 HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1200 Charlotte, NC 28202-2075 704.338.6700 I I I � I I I I - I - - - - 2155 679.07 I I I I - 22.5 bend fm COMBINATION AIR RELEASE I ✓ _ _ N 779410.4 VALVE AND MANHOLE I I I I 2156 E 1813136.6 SEE DETAIL 211/02D-03 I 674.62 STA 46+24 I 22.5 bend fm E ��,-� �r 181313E I N 779420.E 1813135 „^ - I - -18 PVC PIPE E 1813137.8 I I - CB CB CB CB CB CB CB CB CB 2152 - - 675.09 3007 10in 11.25bend fm 2153 684.56 N 779484.5 675.66 684.561 - E 1813143.8 - - 24in casing _ N 779396.4 = - - N 779480.2 _ _ E 1813136.0 . - _ - - E1813143.4 L Z m- - - - - _ (n -00 i _ �0±� 1 00- 42 0 - 43�00 - - - +gam= -_�a = 48 D - - - - AI---42+50 -50- i \+ 46+50 - �+510-- Z I-3�+59-- _ -40*fr m Cl)_ o - T / \ Z _ D T� 2157 00 \ 681.45 \ ) - \ \ 10in gv fm CD \ N 779400.1 \ \ \ E 1813135.7 79 LF OF 24" STEEL CASING BY OPEN CUT / / MIN. THICKNESS 0.250" � L 2151 L- 10" GATE VALVE 2158 680.05 2154 STA 46+12 679.05 I N 779407.47 sleeve _ 10in 11.25 bend fm - 675.5E E 1813136.61 N 779254.7 2150 - N 779510.9 - = 24in casing - _ E 1813123.5 . �- 680.96 = _ - E 1813145.6 N 779427.7 - --- - sleeve I I I f E 1813138.1 --- - N 779529.7 - - - - E 1813147.1 x I II II r- I- I 53 LF OF 24" STEEL CASING BY OPEN CUT I I MIN. THICKNESS 0.250" II II 39+50 40+00 40+50 41+00 41+50 42+00 42+50 43+00 43+50 44+00 44+50 45+00 45+50 46+00 46+50 47+00 47+50 REVISIONS TYPE ROADWAY SEWER 1 2 3 WATER FINAL DESIGN SIDEWALK CONTRACT ICONTRACTORI AS -BUILT I AUTH. DATE I WATER AND SEWER PERMITS 2022-0180 700 670 e 650 • 1, 000, 48+00 40 0 40 80 HORIZONTAL SCALE IN FEET 10 0 10 20 VERTICAL SCALE IN FEET JOB NO. P-05805E-07 DESIGNED 4/2023 BY HDR CONST. SURVEY BY CHECKED BY SCALE: AS NOTED SENSITIVE INFORMATION Not to be copied or distributed without the express written permission of the City of Greensboro. North 8� CarolincOla� City of', Gree oro a rounc Loca es I o e uests COG Water eso ces ep . 73-2033 GDOT Traffi Si a _ _ - 73-2606 COG/Guilf rd Co. Telecom - 73-2084 COG Water upply - - - - - - 73-5855 Tanks Tredtment Plants GDOT Stormer 373-2569 NPDES General Permit Applies DISTURBED AREA OFF PAD = 2.11 AC GIS DISCLAIMER Objects on this map shown with a dotted linestyle were not surveyed, they were compiled by photogrammetric methods, available on the Geographic Information System (GIS) software used by the City of Greensboro. K_ CITY OF GREENSBORO WATER RESOURCES DEPARTMENT Megasite City of Greensboro Wet Utilities Phase 2 MEGASITE FORCE MAIN #1 PLAN AND PROFILE STA 39+00 TO STA 48+00 02C- 04 SHEET NO. 9 of 20 LOCATION MAP CONTRACT SHEET 10 OF 20 Un .'1 .:1 670 ..1 650 M$ 630 to 48+00 IM)l - 2136 677.38 �B cB - °B °B sleeve - N 778921.4 , - - E 1813096.8 - Cn 100 - �0 - _ 50+00 1 0 D 48+_56- 49+50 - - 50+56 41 - - r � In n TV1 ++ � CD 60 LF OF 24" STEEL CASING BY OPEN CUT \ MIN. THICKNESS 0.250" _ n fl> 1 2138 676.73 casing I N 778858.3 E 1813091.8 �X X X _ - 10" X 6" WYE WITH 6" VALVE FOR FUTURE CONNECTION FOR TOYOTA FACILITY STA 54+34 N 778588.94 E 1813065.33 10" C-900 DR-18 PVC PIPE NL 2137 677.72 casing N 778916.9 E 1813096.8 - 52+00- _ 51 2161 _ 672.04 45 bend fm- N 778796.2 - E 1813087.7 ROADWAY DESIGN IN PROGRESS 10" C-900 DR-18 PVC PIPE 2168 670.80 CASING N 778372.0 E 1813104.8 71 LF OF 24" STEEL CASING BY OPEN CUT MIN. THICKNESS 0.250" hcy�/tiF STq SOX 00 h^ x 2163 h 672.37 61N GV FM / N 778293.5 2167 2164 - - E1813�0.3/ / - 670.59 - _ - 7/ 673.19 CASING g X N 778417.4 - h� - _ c 7 N 778582.2 E 1813063.3 E 1813050.1 55+00 -HIV► - / , --- - _ 2166 669.88 / I 2159 / �\ 675.67 \ sleeve \\ 10" 45° FITTING N 778842.2 , (HORIZONTAL) E 1813090.8 = I 2 6`\ STA 55+95 671.41 N 778430.81 10x6 wy e fm E 1813034.70 N 778588.7\\ E 1813064. \ 2160 / \ 10" GATE VALVE \ �_�_ STA 54+42 N 778580,34 45 bend fm �� �\ E 81306181306417 . N 778800.7 \\\\\ \ \ E 1813087.7 10 in 11.25 band ' N 778426.2 I E 18130,39.9 669. /// 669.70 10 IN 45 BEND N 778432.3 / / E 1813035.5/ % / 48+50 49+00 49+50 50+00 50+50 51+00 51+50 52+00 52+50 53+00 53+50 54+00 54+50 55+00 55+50 56+00 56+50 57+00 57+50 HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1200 Charlotte, NC 28202-2075 704.338.6700 REVISIONS TYPE ROADWAY SEWER 1 2 3 WATER FINAL DESIGN SIDEWALK CONTRACT CONTRACTOR AS -BUILT AUTH. DATE WATER AND SEWER PERMITS 2022-0180 SENSITIVE INFORMATION Not to be copied or distributed without the express written permission of the City of Greensboro. Nortalili- Car lia 'a8� Jiwwww.ne811.org1 , City of Grime ro oa rounc Loc es IJ/Re nests COG Water eso c s ep .73-2033 GDOT Traffi Si a _ -73-2606 COG/GuiIf rd Co. Teleco73-2084 COG Wat r upply - - -73-5855 anks a tment PlantsGDOT St rrr� ter _ - _ -73-2569 NPDES General Permit Applies DISTURBED AREA OFF PAD = 2.11 AC GIS DISCLAIMER Objects on this map shown with a dotted linestyle were not surveyed, they were compiled by photogrammetric methods, available on the Geographic Information System (GIS) software used by the City of Greensboro. 690 40 0 40 80 HORIZONTAL SCALE IN FEET 10 0 10 20 VERTICAL SCALE IN FEET ff e 650 • R ff N 00 58+00 JOB NO. P-05805E-07 DESIGNED 4/2023 BY HDR CONST. SURVEY BY CHECKED BY SCALE: AS NOTED K_ I I CITY OF GREENSBORO WATER RESOURCES DEPARTMENT Megasite City of Greensboro Wet Utilities Phase 2 MEGASITE FORCE MAIN #1 PLAN AND PROFILE STA 48+00 TO STA 57+00 02C- 05 SHEET NO. 10OF20 LOCATION MAP CONTRACT SHEET 11 of 20 III F)l HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1200 Charlotte, NC 28202-2075 704.338.6700 \ 10" C-900 DR-18 PVC PIPE I\ I 0 00 0 + 58+50 L0 U LU _Z \ J \ ROADW' Sz OS 45° FITTING (HORIZONTAL) STA 58+82 ii N 778247.20 E 1813256.30 ZX =� TEEL CASING BY OPEN CUT N. THICKNESS 0.250 _ /J / 10" C-90 [`R-18 PVC PIPE / 66 z "0 // � / / 65+50 rn cn / / 63+00 63+50 / 64+ 0 rn 62+00 62+50 // / // / // // / / Cri j 63 LF OF 2_4" STEEL CASING BY OPEN CUT MIN. THICKNESS 0.250" AT SWALE \ _ L — \ 10" GATE VALVE COMBINATION AIR RELEASE- - STA 60+47 = VALVE AND MANHOLE— _— = N 778089.84 SEE DETAIL 211/02D-03 E 1813267.87 — STA 60+60 N778882.37 778081.7 E 1813278.751813280 3008 -�= 684.83 TOP RIM ARV — _ — N 778081.7 — — E 1813280.0 40 0 40 80 — HORIZONTAL SCALE IN FEET 10 0 10 20 VERTICAL SCALE IN FEET 700 .•1 .:1 670 650 .�1 M co 61 —�� 45° FITTING (HORIZONTAL) - \ STA \ 60 8. -- N 1813255.1 — \ E 1813255.12 58+00 58+50 59+00 59+50 60+00 60+50 61+00 REVISIONS 61+50 TYPE ROADWAY SEWER WATER SIDEWALK 62+00 62+50 63+00 63+50 64+00 64+50 65+00 CONTRACT ICONTRACTORI AS —BUILT I AUTH. DATE I WATER AND SEWER PERMITS 65+50 66+00 11, :•1 .:1 670 ..1 650 M LO co rl- co 66+50 JOB NO. P-05805E-07 DESIGNED 4/2023 BY HDR CONST. SURVEY BY CHECKED BY SCALE: AS NOTED K- SENSITIVE INFORMATION Not to be copied or distributed without the express written permission of the City of Greensboro. N o rah 8� Caroli.nc811.erg� Clay of Gree oro er rounc Locates Info a uests C_ COG Water esour es ep . 73-2033 g GDOT Traffi Si 73-2606 COG/Guilf rd Co. Telecom — 73-2084 COG Water upply _ _ — — — — 73-5855 Tanks/Treatment Plants GDOT Storm Water _ — — — 73-2569 NPDES General Permit Applies DISTURBED AREA OFF PAD = 2.11 AC GIS DISCLAIMER Objects on this map shown with a dotted linestyle were not surveyed, they were compiled by photogrammetric methods, available on the Geographic Information System (GIs) software used by the City of Greensboro. CITY OF GREENSBORO WATER RESOURCES DEPARTMENT Megasite City of Greensboro Wet Utilities Phase 2 MEGASITE FORCE MAIN #1 PLAN AND PROFILE STA 57+00 TO STA 66+00 02C— 06 FINAL DESIGN 2022-0180 SHEET NO. 1 • IN LOCATION MAP CONTRACT SHEET 12 of 20 j \ 10" 45' BEND (HORIZONTAL) \ --------- Gj 0 67+ \ \ --rQZ+50 STA 66+73 1 N 777736.47 E 1813785.08— _ 167 LF OF 24" STEEL CASING BY OPEl' MIN. THICKNESS 0.250" COMBINATION AIR RELEASE AT PROPOSED FUTURE ROAD CROSSING VALVE AND MANHOLE _\\\ SEE DETAIL 211/02D-03 STA 69+93 N 777713.61- 777712.9 E 1814103.99-1814104 \\\ 68+00 69+00 70+00 71\\\ \ 70+50 71+50 68+50 6 9FM +50 U \ \ \ R �\ 3009 678.36 II I \� 10" GATE VALVE _ TOP RIM ARV 1 STA 66+96 - N 777734.95 — N 777712.9 I 10" GATE VALVE - - — E 1814107.0 \ _ E 1813807.92 — STA 70+01 — l I N 777713.03 I I �\ I E 1814112.39 I I I I I 700 e 670 % e 66+50 67+00 67+50 68+00 68+50 69+00 69+50 70+00 HDR Engineering, Inc. REVISIONS of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1200 Charlotte, INC 28202-2075 704.338.6700 FINAL DESIGN 70+50 71+00 TYPE ROADWAY SEWER WATER SIDEWALK 71+50 72+00 I I I I ROADWAY DESIGN IN PROGRESS I I I I I ----_-------- \T }�- / / iF 72+ 0— 3+00 i 74+00 7 a PIIII f •. 7 '50 74+50 z .� m _J\ I� M / D `D CD — "I I �lI ilII�� ------ I I III IIII III IIII II IIII IIIII I I I I I IIIII I � I III III IIIII / 72+50 73+00 73+50 74+00 CONTRACT ICONTRACTORI AS —BUILT I AUTH. DATE I WATER AND SEWER PERMITS 2022-0180 700 ••1 •:1 670 e M01 650 M 0 00 co 74+50 75+00 40 0 40 80 HORIZONTAL SCALE IN FEET 10 0 10 20 FM VERTICAL SCALE IN FEET JOB NO. P-05805E-07 DESIGNED 4/2023 BY HDR CONST. SURVEY BY CHECKED BY SCALE: AS NOTED SENSITIVE INFORMATION Not to be copied or distributed without the express written permission of the City of Greensboro. NorthCarallina ICU 8� I VAM COG Water �eso C s ep . 73-2033 GDOT Traffi Si _ — — 73-2606 COG/Guilf�rd Co. Telecom — 73-2084 COG Water upply _ — — — — — 73-5855 Tanks/Tredtment Plants j GDOT Storm Vter 73-2569 NPDES General Permit Applies DISTURBED AREA OFF PAD = 2.11 AC GIS DISCLAIMER Objects on this map shown with a dotted linestyle were not surveyed, they were compiled by photogrammetric methods, available on the Geographic Information System (GIS) software used by the City of Greensboro. 1 K- CITY OF GREENSBORO WATER RESOURCES DEPARTMENT Megasite City of Greensboro Wet Utilities Phase 2 MEGASITE FORCE MAIN #1 PLAN AND PROFILE STA 66+00 TO STA 75+00 02C— 07 SHEET NO. 12OF20 LOCATION MAP CONTRACT SHEET 13 of 20 F)l HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1200 Charlotte, NC 28202-2075 704.338.6700 i I — — D nn 76+00 n 75+50 r Z m rn -1 D M 0 CDf 700 1:0&4101 e i 670 S Me e m ►. ROADWAY, SUBJECT TO CHANGE � � / — � I \ \ \\ \ \\\ \\ ✓ / 0VC PIPE _ 77+00 78+00 76+50 77+50 10" GATE VALVE POLYMER MANHOLE 72" 24" C-900 DR-18 PVC PIPE STA 78+85 MANHOLE 2-1 ( ) N 777650.27 STA 79+22 �� 0.' - b�R 8 oP1�E �0 � E 1814993.84 RIM =676.64 , / \\\ \ \\\ \\ \ 24" OUT (E) IE = 678.66 670.96 �� \ 79+00 80+00 81+00 82+00 83+00 81+50 82+50 80+50 78+50 79+50 S -as s 83xs� �0 MANHOLE MH 2-2 _ —_— STA 83+22 RIM = 678.16 677.98 24" IN (W) IE = 668.72 668M6 — 24" OUT (SE) IE = 668.69 66B-.79_—_ - — J _ = 96 LF OF 36" STEEL CASING BY - — — — OPEN CUT MIN. THICKNESS 0.375" — o CID (0Co 00 w J I- Q0 O zII Q N d7 II 3 N w J NU N � = CO � W W - - - - - - - - - - - - - - - _______________ O + _ O < II W N C coo '----_ � Z O _-_,-- EXISTING GRADE, TYP O co = 00 =O O Q F — _ W 2(n Q'N II w Z ZQ CDN �(n Q' N 10" C-900 DR-18 PVC PIPE 400 LF 24" C-900 DR- 8 PVC PIPE @ 0.32% ----- \ 96 LF OF 36" STEEL CASING BY ----- _ 10" GATE VALVE OPEN CUT MIN. THICKNESS 0.375" STA 78+85 ROCK ELEVATION, TYP. SEE AERIAL CROSSING DETAILS ON SHEET w � � 02D-02 & 02D-03 0- o0 w �r �00 + w U) p Q m Z U) I Lu ALL FORCE MAIN PIPE SHALL BE INSTALLED ON A NEGATIVE SLOPE OF 0.1 % OR GREATER N N O 0) 1 M 'T 00 .7 N 0' O OLO M 00 u7 M 0) 00 � LO ti O N 0� M O to co N C0 C0 CD O LO CV N r-- Ou7 ti 00 00 ti O 00 00 O O O — O ti 00 � 00 ti M ti � r— Cfl O 00 o0 M ti M � r� ti 0) ti O ti 11 O � CO CM C0 r C0 00 (0 1fl 1fl 1fl ~ C0 (0 (0 (0 C0 (0 CO (D (0 ~ Cfl (0 C0 (0 O (D C0 (0 (0 O C0 C0 C0 C0 O O O C0 C0 (0 O C0 ( O O (0 (0 C0 ~ CO C0 (0 C0 C0 r` C0 C0 (0 C0 C0 (0 C0 /b+bu /ti+UU 16+bu / /+UU / /+bu /t3+UU REVISIONS FINAL DESIGN /t3+bu 19+UU TYPE ROADWAY SEWER WATER SIDEWALK 19+bu uu+UU MU+bu 61+UU 61+bu 62+UU 62+bu 63+UU CONTRACT ICONTRACTORI AS —BUILT I AUTH. DATE I WATER AND SEWER PERMITS 2022-0180 t33+bu 64+UU JOB NO. P-05805E-07 DESIGNED 4/2023 BY HDR CONST. SURVEY BY CHECKED BY SCALE: AS NOTED 700 . O 1 670 ..1 M911 M SENSITIVE INFORMATION Not to be copied or distributed without the express written permission of the City of Greensboro. North 8� Carolina www.nc811.org� � , �tz COG Water eso ces ep . 73-2033 GDOT Traffi Si a _ — — 73-2606 COG/Guilf rd Co. Telecom — 73-2084 COG Wat r upply _----- 73-5855 Tanks/'T,re tment Plants GDOT Storm \4qter _ — — — �73-2569 NPDES General Permit Applies DISTURBED AREA OFF PAD = 2.11 AC GIS DISCLAIMER Objects on this map shown with a dotted linestyle were not surveyed, they were compiled by photogrammetric methods, available on the Geographic Information System (GIS) software used by the City of Greensboro. 40 0 40 80 HORIZONTAL SCALE IN FEET 10 0 10 20 VERTICAL SCALE IN FEET K- CITY OF GREENSBORO WATER RESOURCES DEPARTMENT Megasite City of Greensboro Wet Utilities Phase 2 MEGASITE FORCE MAIN #1 PLAN AND PROFILE STA 75+00 TO STA 84+50 02C— 08 SHEET NO. 13OF20 LOCATION MAP I 1 I " \ �l� / I I l 'A I I I I f l IIIII / I f r I � � r� fIIIII ll IIIIII > l � � /SEE EROSION CONTROL SHEET 05E-05 l l l l I I I I I I\ MANHOLE MH 2-3 f I / \ I I l \J / // r _ \J I I III I I I STA 85 72 �- + 0� RIM -�3 667.20 I 7 I I 1 I / / / / I 15257 T W 24" IN (NW) IE fi68.46 660.6d I - 24 C-900 DR-18 PVC PIPE 1F 631.24 I I I I 8 24" OUT (SE) IE �60.36-660.52 MANHOLE MH 2 4 / 1 MH-2-5 I I I 15+ ( 86+00 I / 1 STA 87 73 RIM = 656.53 655.87 N 777306.E / I / 24" IN (NW) IE =0 648.01 / / / d I I - E 1816188.9 ' �--- g 86+50 87+pd I 24" OUT (E) IE =fi48 9�647 91 r �� 1 La_-� �U1� J1J I f 8k5o' I+00 J J I 1 g + I / 92+0092 I i 88+50 / /89+5 g +p I + 0 92 ,- ► \ 84 LF OF 36 STEEL CASING BY \\ \ OPEN CUT MIN. THICKNESS 0.375" / II II , �- rl I 1 11 1 11 1 III / 1 I ill IIII III (IIIIII IIII 1 I II l .:1 670 650 M 630 620 I' I - z Cn o MANHOLE MH 2-5 l STA 91+43 / I I I I RIM = 63-1.15 631.07 / 1 24" IN W IE = 5 620.40 d I I 1 24" OUT (E) IE=626�5-620.35 r � ��� ,�4,, 85+00 85+50 86+00 86+50 87+00 87+50 88+00 88+50 89+00 89+50 90+00 90+50 91+00 91+50 92+00 .:1 ••t 650 M1 K- CONTRACT SHEET 14 of 20 SENSITIVE INFORMATION Not to be copied or distributed without the express written permission of the City of Greensboro. Nori '�Iinal� 1 www.nc811.org� city COG Water es0 ces ep . 73-2033 GDOT Traffi S a _ — — 73-2606 COG/Guilf rd Co. Telecom — 73-2084 COG Wat r upply - — — — — — Tanks Tre tment Plants GDOT St I ter�73-51155 73-2569 NPDES General Permit Applies DISTURBED AREA OFF PAD = 2.11 AC GIS DISCLAIMER Objects on this map shown with a dotted linestyle were not surveyed, they were compiled by photogrammetric methods, available on the Geographic Information System (GIS) software used by the City of Greensboro. 40 0 40 80 HORIZONTAL SCALE IN FEET 10 0 10 20 VERTICAL SCALE IN FEET H)l HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1200 Charlotte, NC 28202-2075 704.338.6700 REVISIONS TYPE ROADWAY SEWER 1 ZL 3 WATER FINAL DESIGN SIDEWALK CONTRACT ICONTRACTORI AS —BUILT 1 AUTH. DATE I WATER AND SEWER PERMITS 2022-0180 JOB NO. P-05805E-07 DESIGNED 4/2023 BY HDR CONST. SURVEY BY CHECKED BY SCALE: AS NOTED CITY OF GREENSBORO WATER RESOURCES DEPARTMENT Megasite City of Greensboro Wet Utilities Phase 2 MEGASITE FORCE MAIN #1 PLAN AND PROFILE STA 84+50 TO STA 93+00 SHEET NO. 14OF20 LOCATION MAP CONTRACT SHEET 15 of 20 623.44 MANHOLE MH 2-7 I _ l MH 2-7 STA 96+00 N 777146.8 \ 1 I M -68 623.43 E 181661 �' I " IN (NW) IE = 609.88608.79 UT (SW) IE=688.98 60886 sx,° o 9 J V 24' C 900 Dft-18 PVC P,41!5E \ SEE EROSION CONTROVSHEETS/ \ I 1 \ 05E-04 & 05E-05co — \� \ \ \ \ \ or'�' �\ \� V I MANHOLE MH 6 t \ \� 9 \ /1 I \ / p \\\ STA 94+28 \\� \ \\ �XSO 60 - J\ \ W "+00 101+50 Ei z RIM =fr19 60 618.64 \\ \ \ \\ m 621.77 ( +5 / \ 24 IN (W) IE = 5-609.9� 100+00 '1� l� O \ 24" OUT (SE) IE=r609.98 -� \ \ MH 2-8 \ \D \ \ \ 99 N 776898.0 3 E 1816454.1 — + \ \ \ \ J i(q- 4 \ MANHOLE MH 2-8 k- \ \ \ _, ( \0 I ✓ \ STA 98+96 Ch'</iy RIM =621.76 621.76 / � 24" IN (NE) IE - 606.96 606,�D 85 - _ MANHOLE MH 2-9 \ �\ O �\ 24" OUT (S) IE = 666.86 6 f STA 101+92 v 93x0J RIM = fir. 60 614.81 24" IN (N) IE = 605.92 605.72 L J^-- ` \ -1 _ _ \ ✓ 24" OUT (SE) IE=665-82 605.71 e 630 620 met, e 590 40 0 40 80 HORIZONTAL SCALE IN FEET 10 0 10 20 VERTICAL SCALE IN FEET 650 0 630 620 G'�iM 590 SENSITIVE INFORMATION Not to be copied or distributed without the express written permission of the City of Greensboro. Northir, Caro linawV wWM811.8rg �tz COG Water esa ces ep . 73-2033 GDOT Traffi Si a _ _ _ 73-2606 COG/Guilf rd Co. Telecom _ 73-2084 COG Wat r upply _----- 73-5855 Tank,/T�e tment Plants GDOT Storm �er _ — — — ��73-2569 NPDES General Permit Applies DISTURBED AREA OFF PAD = 2.11 AC GIS DISCLAIMER Objects on this map shown with a dotted linestyle were not surveyed, they were compiled by photogrammetric methods, available on the Geographic Information System (GIS) software used by the City of Greensboro. HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1200 Charlotte, NC 28202-2075 704.338.6700 REVISIONS TYPE ROADWAY SEWER 1 2 3 WATER FINAL DESIGN SIDEWALK CONTRACT ICONTRACTORI AS —BUILT 1 AUTH. DATE I WATER AND SEWER PERMITS 2022-0180 JOB NO. P-05805E-07 DESIGNED 4/2023 BY HDR CONST. SURVEY BY CHECKED BY SCALE: AS NOTED CITY OF GREENSBORO WATER RESOURCES DEPARTMENT Megasite City of Greensboro Wet Utilities Phase 2 MEGASITE FORCE MAIN #1 PLAN AND PROFILE STA 93+00 TO STA 102+00 101/ SHEET NO. 15OF20 LOCATION MAP CONTRACT SHEET 16 of 20 \ \ MANHOLE MH 2-10 �� ^n I \ 15256 STA / / J[ Ir` k S 1 / / 619.57 RIM = 619.99MH I \_ / I N 2-106.3 C 24" IN (NW) IE = 604.47 24" C- DR- 81PP �P / 24 00 OUT (S) IE = 604.37 _, _ � / r E 1816861.5 20' TEMPO�hARY x�0 )06+ 10 / -►y - / 15255 CONSTRUCT?MI�Ef�I� EASE MH22 , 612.76 �07+50 108+00 - / N 775994.4 / E 1816812.1 108+50 10 ✓LF-pF J / ( 10g+ �� ,� -�� SEE SHEEN 7.65 �O \✓ / SEE -EROSION CONTROL SHEETS 05E 04 & 05E 05 x \ �y / BEGINNING PHASE V I--,'/ ( \ \ / SANDY CREEK OUTFALL --� / f / I I // �- STA 109+47 •� / ~ J j� \ ) - RIM = 611.40- /- 24" IN (N) IE - 596.76 ti MH-22 - J STA58+10.33 E 1816811.47\\ MEGASITE PROPERTY BOUNDARY — / _, � \ \`\ 15261 614.82 M H 2-9 650 L. 1 1 620 610 46011 109+47.3�X_-- PHASE V SANDY CREEK OUTFALL PROJECT NUMBER: P05805E _ 4--- _41 T T T T T T T T T T T T T T T T T T T T T T T T T T T�TTTTTTTTTTT T \T T T T TAT T T T T T n n m m a 4, m m m 4, m r T T T T T � T T T T T T T T T TIT T T TTTTT TTTTT T�TTTTTTTTTT ` TTTTT f J \ �< /I \ °l CM O C) � CD N II II 2 W W_ 2E qzt > J + 0-, 0 CO O O Z 2— J i Q II Z O W LL EXISTING GRADE, TYP U N N W Y LID (� W II Z U W Z + � ^ Z}oZ�Z Op—nZ W ZQ 0°Q�� ROCK ELEVATION, TYP 422 LF 24" C-900 D -18 PVC PIPE @ 0.32% 333 L 24" C-900 DR-"' 29 LF 24" PIPE PVC PE @ 2.28% a7 (M M LID N � O 00 � O 00 O O ti ll') 00 M � Uf N O ti Lr) O 00 � O O U r O CO � O co O CO � a0 Ln Cn N 00 N N N 00 — 00 Ln Cn O O O O O (0 - r N O O O O co (0 O N O O N (D CO (D O O O O O r O O r O O � ( O (D O (D O O 40 0 40 80 HORIZONTAL SCALE IN FEET 10 0 10 20 VERTICAL SCALE IN FEET SENSITIVE INFORMATION Not to be copied or distributed without the express written permission of the City of Greensboro. North Iina�� 8� awww.nc811.or9A City COG Water eso ces ep . 73-2033 GDOT Traffi Si a _ — —1.73-5855 73-2606 COG/Guilf rd Co. Telecom 73-2084 COG Wat r upply _ — — — — Tanks Tre tment Plants GDOT St rri ter _ — — — 173-2569 NPDES General Permit Applies DISTURBED AREA OFF PAD = 2.11 AC GIS DISCLAIMER Objects on this map shown with a dotted linestyle were not surveyed, they were compiled by photogrammetric methods, available on the Geographic Information System (GIS) software used by the City of Greensboro. 1U2+5U 1U3+UU 1U3+5U 1U4+UU 1U4+5U 1U5+UU 1U5+5U 1U6+UU 1U6+5U 1U7+UU 1U/+5U 1U13+UU 1U13+5U 1U9+UU 1U9+5U 11U+UU 11U+bL K- HDR Engineering, Inc. REVISIONS TYPE CONTRACT CONTRACTOR AS —BUILT AUTH. DATE WATER AND SEWER PERMITS JOB NO. P-05805E-07 CITY OF GREENSBOROof 02C-11 the Carolinas NCBELSLicense No. F-0116 ROADWAY DESIGNED 4 2023 BY HDR WATER RESOURCES DEPARTMENT S.te,NC 8202-ite5 Charlotte, Charlotte, NC 28202-2075 SEWER 2022-0180 CONST. SURVEY BY Megasite City of Greensboro Wet Utilities Phase 2 SHEET NO. 704.338.6700 1 ZL 3 WATER CHECKED BY MEGASITE FORCE MAIN #1 PLAN AND PROFILE 16 OF 20 FINAL DESIGN SIDEWALK SCALE: AS NOTED STA 102+00 TO STA 109+06 NOTE: NO ENCASEMENT REQUIRED FOR SPACE GREATER THAN 24" FOR SEWER LINES )I LL IT MI,' :NCH CON _LER PROPOSED PIPELINE OVER EXISTING PIPE CONCRETE CRADLE DETAIL NOT TO SCALE SIZE OF BEND THRUST REQUIRED RODS MAXIMUM SIZE EACH STRAP 11-1/4 831 IDS. 2 EACH @ 1/2" DIA. 2"x1/2" THICK 22-1/2 ° 1, 655 IDS. 2 EACH e 1/2" DIA. 2"x1/2" THICK 6„ 45 ° 3, 246 IDS. 2 EACH @ 1/2" DIA. 2"x1/2" THICK 90' 5998 IDS. 2 EACH @ 1/2" DIA. 2"x1/2" THICK PLUG 4,241 Ibs. 2 EACH @ 1/2" DIA. 2"x1/2" THICK 11-1/4' 1,478 Ibs. 2 EACH @ 1/2" DIA. 2"x1/2" THICK 22-1/2' 2, 942 Ibs. 2 EACH @ 1/2" DIA. 2"x1/2" THICK 8 45' 5771 IDS. 2 EACH @ 5/8" DIA. 2"x1/2" THICK go. 10, 663 Ibs. 2 EACH @ 3/4" DIA. 2"x1/2" THICK PLUG 7540 Ibs. 2 EACH @ 3/4" DIA. 2"x1/2" THICK 11-1/4' 2,310 Ibs. 2 EACH @ 1/2" DIA. 2"xi/2" THICK 22-1/2' 4, 597 Ibs. 2 EACH @ 5/8" DIA. 2"x1/2" THICK 10" 45' 9, 017 Ibs. 2 EACH @ 3/4" DIA. 2"xi/2" THICK 90, 16,661 Ibs. 2 EACH @ 1 " DIA. 2"x1/2" THICK PLUG 11,781 IDS. 2 EACH @ 7/8" DIA. 2"xi/2" THICK 11-1/4' 3, 326 IDS. 2 EACH @ 3/4" DIA. 2"x1/2" THICK 22-1/2 ° 6, 619 Ibs. 2 EACH @ 3/4" DIA. 2"x1/2" THICK 12" 45' 12,984 Ibs. 2 EACH @ 7/8" DIA. 2"x1/2" THICK 90 ' 23,992 IDS. 2 EACH @ 1 " DIA. 2 "x1/2" THICK PLUG 16,965 lbs. 2 EACH @ 1 " DIA. 2"x1/2" THICK 11-1/4 ° 5,912 Ibs. 2 EACH @ 7/8" DIA. 2"x1/2" THICK 22-1/2 ° 11, 768 Ibs. 2 EACH @ 7/8" DIA. 2"x1/2" THICK 16" 45' 23,083 IDS. 2 EACH @ 1-1/8" DIA. 2"x5/8" THICK 90' 42, 652 IDS. 2 EACH @ 1-1/4" DIA. 2"x5/8" THICK PLUG 30, 159 Ibs. 2 EACH @ 1-1/4" DIA. 2"x5/8" THICK NOTES.' STEEL RODS ARE CALCULATED ON THE BASIS OF NET THREADED SECTION USING MAXIMUM TENSILE STRESS OF 20,000 PSI. STRAPS ARE CALCULATED ON BASIS OF MAXIMUM SHEAR STRESS OF 13, 000 PSI. ALL RODS AND STRAPS ARE TO BE HEAVILY COATED WITH AN APPROVED BITUMA5TIC COMPOUND. C/ T Y O F G R E E N S B O R O STANDARD FOR RODS AND STRAPS STD. NO. REV. TO HOLD FITTINGS WHERE CONCRETE oB-02 REACTION BLOCKING CANNOT BE USED 12 09-°0 1 PROPOSED PIPELINE UNDER EXISTING PIPE NOTES: 1. CONCRETE SHALL BE 2500 P.S.I. MIN. 2. REINFORCING BARS SHALL BE DEFORMED AND TIED TOGETHER. 3. TRENCH BOTTOM WIDTH IN VICINITY OF THRUST BLOCK(S) INSTALLATION SHALL IIXII BE MINIMUM WIDTH. 4. BACKFILL TAMPED IN 6" LAYERS. 5. KEY THRUST COLLAR INTO UNDISTURBED SOIL ALONG SIDES AND BOTTOM OF TRENCH. THRUST COLLAR IrvIf ID A to C_ oQz M 0 J 0'0 7 p gPti. Qopo PF ,�V�� V� 0 PA SP p Gj 00 QP �P 00 �Q� �Q 0 tiGti� G o0 F 0ti �� Fp p. 2 0 ti0 P�,O, Fti 0P P OJyO Q0 ti Q 6" 11-1/4' 812 1 FT2 1 1 1 1 1 1 1 22-1/2' 1653 1 FT2 1 1 1 1 1 2 1 45' 3247 1 FT2 2 1 1 1 1 4 1 90' 5994 2 FT2 3 1 1 1 2 6 1 PL UG 4239 1 FT-' 2 1 1 1 1 4 1 B" 1444 1 FT2 1 1 1 1 1 2 1 2939 1 FT2 2 1 1 1 1 3 1 11-1/4° 22-1/2, 45° 5773 2 FT2 3 1 1 1 2 6 1 90° 10656 3 FT2 6 1 2 1 2 1 3 11 2 PL UG 7536 2 FT2 4 1 2 B 1 12" 11-1/4' 3248 1 FT2 2 1 1 1 1 3 1 22-1/2' 6612 2 FT2 4 1 1 1 2 7 1 45' 12988 3 FT2 7 1 2 2 3 13 2 90' 23976 6 FT2 12 2 3 3 6 24 3 PLUG 16956 4 FT2 9 1 2 2 4 17 2 16" 11-1/4' 5775 2 FT2 3 1 1 1 2 6 1 22-1/2' 11756 3 FT2 6 1 2 1 3 12 1 45' 23090 6 FT2 12 2 3 3 6 23 3 90' 42624 11 FT2 22 3 6 6 11 43 4 PLUG 30144 8 FT2 15 2 4 4 B 30 3 BASED ON TEST PRESSURE OF 150 PSI NOTES.' REACTION BEARING AREAS ARE IN SOUARE FEET MEASURED IN A VERTICAL PLANE IN THE TRENCH SIDE AT AN ANGLE OF 90 ' TO THE THRUST VECTOR. USE 5`90 ° BEND VALUE FOR HYDRANTS FOR ADDITIONAL SAFETY. ClT Y OF GREENSBORO STANDARD REACTION BEARING AREAS FOR STD. NO. REV. HORIZONTAL WATER PIPE BENDS 105 firm UNU15 I UKbtzU SUIL Fm 11—I I-111-111—III =1 11=1 11=1 11=1 11= 3" MIN. CLEAR. REINFORCING REQUIREMENTS REINFORCING BAR SCHEDULE ill—'' I 11=1 11=1 11=1 MIN.I �LEA�. =III=III= 4 _ I - 4 4 4 4 4 4Ih a a ° 4 4 4 4 4 4 4 4 a 4 4 a a 4 a 4 4 4 4 4 d a d a a a 4 44 a 4 4 a aa 4 4 4 4 4 a 4 44 4 1=1 11=1 11=1 11=1 "B" FINISH PAVEMENT WATER LINE %CLASS B CONCRETE, 2500 PSI I� I �I I :.• 07 Haas SUFFICIENT BEARING AREA TO SUPPORT CONCRETE ACTUAL AMOUNT TO BE DETERMINED BY FIELD I- ENGINEER, 2 CY* BEARING AREA FROM TABLES FOR HORIZONTAL BENDS CUBIC YARDS OF CONCRETE TO ANCHOR VERTICAL BEND PIPE DIA. 11-1/4 " ' BEND 22-1/2 " ' BEND 45 ' BEND 6" B12 / 1/2 CY 1653 # i/2 CY 3247 / 1.0 CY 8" 1444 / 1/2 CY 2939 / 3/4 CY 5773 if 1.5 CY 12" 3248 OF 1.0 CY 6612 / 1-3/4 CY 129880 3.5 CY 16" 5775 OF 1-1/2 CY 11756 / 3.0 CY 23090 0 6.0 CY C/ T Y O F C R E E N S B O R O Is STD. NO. REV. STANDARD VERTICAL BEND ANCHORS 11 08-02 03-03 • BACKFILL TO EXTEND TO J J UNDERSIDE OF SLAB OR z U BOTTOM OF BASE COURSE U_ Q FOR PAVEMENT m COMPACTED ABC/3" MINUS STONE (AASHTO M-43) IN 4" LAYERS COMPOSITE SECTION BACKFILL FOR PIPING UNDER PAV'T BACKFILL FOR PIPING IN OTHER AREAS J J FINISHED GRADE EXCAVATED MATERIALS SUITABLE FOR COMPACTION BY TESTING LABORATORY LAID IN 8" LOOSE LIFTS AND COMPACTED FOR ENGINEERED FILL J N 0°v�0°v�o Y SIDE OF TRENCH IF z 1 r ° ° oo�° °�PC, U ADEQUATELY o z Y �o oa°O m BRACED TO MEET 0 o U _ o° 0 SAFETY CODES AND m z m CO ° oog U REGULATIONS Q — z I.D. PIPE REBAR SIZE "X"BAR LENGTH "X" BAR WGHT. "Y" BAR LENGTH "Y" BAR WGHT. NO. READ. 6"-36" #5 2'-2"+O.D. PIPE 1.043 LBS./FT 1'-1" 1.1 LBS. EA. X-24,Y-12 48" #6 3'-0"+O.D. PIPE 1.502 LBS./FT 1'-3" 1.9 LBS. EA. X-24,Y-12 REINFORCING BAR SCHEDULE I.D. PIPE "A" "B" "C" - 6"-1611, 20"-2411, 30"-3611, 48" 6"-36" 1'-4" 1'-7" 2" 3" 4" 48" 1'-8" 1'-9" 6" THRUST COLLAR FOR PIPE NOT TO SCALE -1 IIIIII IIII I C, W m PIPE OD I I \ 3" MIN 3" MIN 12" MAX 12" MAX PIPE BEDDING AND BACKFILL NOT TO SCALE #57 OR #67 STONE IN 4" LAYERS F)l HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1200 Charlotte, NC 28202-2075 704.338.6700 R RING 6 COVER 2g 7" ..a'. 24I.D. o �R COG STD. Nd v #206 -0" RING ✓DINT - - - - - - - - - - - - ASTM C-361 a.' 3 4 ' -0 " I. D. (#200) to -5 oM^o R oo W Mco 5'-0" 1. D. (#201) R .a ° -p° * BRICK < O I I I I n�m °.. �4 0 5'-10" STD. #200 lu 6'-10" STD. #201 6'-0" PRECAST INVERT SECTION A -A `O SECTION B-B NOTES.' ON NEW INSTALLATION A MAX. OF TWO GRADE RINGS SHALL BE USED. CONCRETE SHALL BE CLASS AA, 4000 PSI AS PER ASTM C-478. STEEL REINFORCING SHALL MEET ASTM C-185 (4' DIA) OR ASTM C-478 (5 ' DIA) . MANHOLES OVER 3'-6" IN DEPTH SHALL BE PROVIDED WITH STEPS 16" ON CENTERS STEPS SHALL BE IN ACCORDANCE W/ COG STD. #206. MANHOLES (MAX. PIPE 0. D. MH DIA 45 ' DEFL 90 ' DEFL 4' 31-1/2" 25" 5' 42" 32" 6' 51" 38" M PRECAST INVERT (OPTIONAL) PLACE 12 " OF #57 STONE UNDER BASE C/ T Y O F G R E E N S B O R O S STANDARD 4' I. D. 6 5' I. D. ECCENTRIC PRECAST STD. NO. REV. 98 CONCRETE SANITARY MANHOLE WITH EXPANDED BASE 200 05-93 03-OB-02 20 -tog 09-9.5 COVER =MIN WT = 125 LBS (4) 1,12 DRILL AND ASTM A48-CL35 g FRAME = MIN WT = 100 LBS TAPPE17 BOLT HOLES AASHTO M306 0 5/8" LETTERING \ RECESSED FLUSH 1" SPECIAL LETTERING o RECESSED FLUSH 6 0 R O, ti O �580 A ��`� �? O 0� A � n Y LIL Ir O (4) 1 " CORED HOLES 1 7 90 ' ON CENTER ti 1805 0 0 C N (4) 1/2"-13 X 2" (1) 1 1/4" VENT HOLE WITH S. S. HEX. HEAD BOLTS 90 . CRETEX PL UG WITH S. S. WASHERS 5/8" LETTERING PLAN VIEW RECESSED FLUSH 2'5 " 1/8" 23 3/4" FLAT GASKET 23 1/2 " 1" CORED DETAIL 1/8' 1 •• HOLE (TYP.) - 4 ,. 112 19 1/2" e'1 ' 3 3/8" 24 1/4" m 31 ., N SECTION A -A NOTES.' N ALL DIMENSIONS AND TOLERANCES ARE TO BE CONCENTRIC AND WILL SUPERSEDE W ANY ASTM STANDARDS WITH A MAXIMUM VARIATION t 1/16 ' ON ALL DIMENSIONS. LL MANHOLE RING TO BE ANCHORED WITH 11/2" REDHEAD STAINLESS STEEL ANCHORS = a AND SEALED BETWEEN RING AND CONE WITH BITUMASTIC SEALER. a ♦ MACHINED BEARING SURFACE o N C/ T Y OF G R EEN S B O R O STANDARD WA TER TIGHT MANHOLE STD. N0. REV. 205-B MAR-97 DEC-05 MAR4 x RING AND COVER MAR-01 GENERAL NOTES: I . RESTRAINED JOINT PIPE AND FITTINGS SHALL CON515T OF BOLTED RETAINER RINGS AND WELDED RETAINER BARS OR 13OLTLE55 TYPE WHICH INCLUDE DUCTILE IRON LOCKING SEGMENTS AND RUBBER RETAINERS. BOLTS FOR RESTRAINED JOINTS (IF APPLICABLE) SHALL CONFORM TO AN51 1318.2. RESTRAINED PIPE SHALL BE C-900 DR-18 PVC PIPE. CONCRETE PROPERTIES SHALL BE AS FOLLOWS: CONCRETE COMPRESSIVE STRENGTH = 4000 P51 NOMINAL SLUMP = 4 INCHES 2. WATER/CEMENTITOU5 MATERIALS RATIO = 0.45 (MAX) AIR CONTENT = G%' 1 .5% CONCRETE SHALL BE COMPOSED OF CEMENT, WATER, COARSE AGGREGATES, FINE AGGREGATES AND AIR. CEMENT SHALL BE TYPE 1/II OR II IN ACCORDANCE WITH A5TM C-150. MATERIAL REQUIREMENTS FOR ALL FINE AND COARSE AGGREGATES SHALL CONFORM TO A5TM C-33. COARSE AGGREGATE SHALL BE SIZE No. 57 OR G7. AN APPROVED CLASS 'FFLYA5H MAY BE SUBSTITUTED FOR AN EQUAL AMOUNT OF CEMENT BY WEIGHT UP TO 25%. ALL EXPOSED CONCRETE CORNERS SHALL BE CHAMFERED 3/4" CONVENTIONAL REINFORCING STEEL SHALL CONFORM TO A5TM AG 15 GRADE GO AND SHALL BE PLACED IN 3. ACCORDANCE WITH "RECOMMENDED PRACTICE FOR PLACING REINFORCING BARS" (LATEST EDITION) AS PUBLISHED BY THE CONCRETE REINFORCING INSTITUTE. SPLICES SHALL BE CLASS 5' CONFORMING TO THE 4. PROVISIONS OF ACI 318 -"BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" NEOPRENE BEARING PADS SHALL BE FORMED FROM PREVIOUSLY UNVULCANIZED, 100% VIRGIN NEOPRENE, WITH DUROMETER HARDNESS = 50. 5. PILES SHALL BE STRUCTURAL STEEL HP 12x53 PILES AND SHALL CONFORM TO THE REQUIREMENTS OF A5TM A3G. PILES SHALL BE DRIVEN TO DEPTHS REQUIRED TO OBTAIN AN ULTIMATE BEARING CAPACITY OF NOT LE55 THAN TWO TIMES THE DESIGN LOADING OF 30 TONS. PILES SHALL PENETRATE A MINIMUM OF FIFTEEN G. FEET INTO UNDISTURBED SOIL. IN DRIVING PILES, A METHOD APPROVED BY THE ENGINEER SHALL BE USED WHEREBY THE HEAD OF THE PILE 15 NOT DAMAGED. IF REQUESTED BY THE ENGINEER, PILES SHALL BE TESTED TO DETERMINE THE ULTIMATE CAPACITY OF THE PILES. THE METHOD OF LOAD TESTING SHALL CONFORM TO A5TM D 1 143 AND THE NORTH CAROLINA STATE BUILDING CODE. WHERE PILES ARE EXPOSED, PILES SHALL BE PAINTED AND/OP COATED IN ACCORDANCE WITH THE CITY SPECIFICATIONS. AERIAL PIPE CROSSING GENERAL NOTES NOT TO SCALE 7/B " LOCKING M\" o RINGS \� STOP O " 8 3/4 V/ O 1" O 1 1/4„ 5/8" O 1/4„ Q PLAN ti h SIDE ELEVA TION 1/B " COMPOSITE 1/4„ h ELEVA TION h COPOL YMER -d - POL YPROPYLENE •- - PLASTIC .e•. a• a: Q ' a • : a °' #3 DEFORMED ' = STEEL ROD G a - _d a ; a : d _a _ a•' - ... 4 STOP DEPTH INTO - CONCRETE SURFACE SECTION A -A 9 N 0 N 3 1/2 " N C/ T Y OF G R EENS B OR O STD. N0. REV. STANDARD MANHOLE STEP FOR 206 w PRECAST CONCRETE MANHOLE PILE SUPPORTED PIER SEE 2/02D-03 * 3/02D-03 AND NOTE 3 DIP CARRIER PIPE WITH RESTRAINED JOINT FITTINGS BETWEEN MANHOLES (SEE NOTE 4) CLA55 I RIP -RAP SLOPE PROTECTION, TYP EXTEND RIP -RAP 2'-0' PAST WATER LINE, TYP L5TEEL CASING PIPE � o EDGE OF WATER SEE 5/02D-03 18„ FOR SUPPORTS PLACED IN STREAM NOTES: TYP I . RIP RAP FOR SLOPE PROTECTION SHALL BE CLA55 I RIP RAP IN ACCORDANCE WITH SECTION 8G6 OF THE NORTH CAROLINA DEPARTMENT OF TRANSPORTATION'S "STANDARD SPECIFICATIONS FOR ROAD5 AND BRIDGES" RIP RAP SHALL BE PLACED IN ACCORDANCE WITH DRAWING 2' 6G8.01 OF THE NORTH CAROLINA DEPARTMENT OF TRANSPORTATION'S "ROADWAY STANDARD DRAWINGS" SUPPORT TYPE FOR PIERS SHALL BE DETERMINED BY ENGINEER BASED ON 5UBGRADE CONDITIONS AT SITE. SEE 1 /02D-03 FOR 3' 5UBGRADE PARAMETERS FOR EACH TYPE OF FOUNDATION. MANHOLE, TYP CONCRETE PIER SEE I/02D-03 AND NOTE 3 4. WHERE DUCTILE IRON PIPE IS USED FOR CARRIER PIPE, DUCTILE IRON CARRIER PIPE SHALL BE INSTALLED UTILIZING 2 PIPE ALIGNMENT GUIDES PER JOINT ONE FOURTH OF THE PIPE JOINT LENGTH IN FROM BOTH THE BELL AND SPIGOT ENDS. AERIAL PIPE CROSSING TYPICAL PLAN NOT TO SCALE VARIES 2' 0" G' 0" MAXIMUM PIPE SPAN TYP MIN SEE ATTACHED TABLE 4'-0" 3/4" 5TAINLE55 STEEL CLA55 I TYP ANc oR rsoLrs s RIP -RAP SLOPE srRAPs PROTECTION, TYP _I � STEEL CASING PIPE PILE SUPPORTED PIER _ SEE 2/02D-03 * 3/02D-03 -- AND NOTE 3 CREEK CHANNEL OR FLOOD PLAIN ALLOWABLE SPANS FOR STEEL CASING PIPE CARRIER PIPE, DIP DIAMETER (IN.) CASING PIPE, STEEL DIAMETER (IN.) MINIMUM CA51NG PIPE WALL THICKNESS (IN.) ALLOWABLE SPAN (fT') G 14 0.3750 40 8 I G 0.3750 45 10 18 0.3750 50 12 20 0.3750 50 14 24 0.3750 55 I G 2G 0.3750 55 16 30 0.3750 GO 20 32 0.3750 GO 24 3G 0.4375 G5 30 42 0.4375 G5 3G 48 0.500 G5 42 5G 0.5000 G5 3-0" MIN FROM BOTTOM OF CREEK OR FLOOD PLAIN RN901 MANHOLE, TYP 3/4" 5TAINLE55 STEEL ANCHOR 80LT5 4 STRAPS -DIP CARRIER PIPE WITH RESTRAINED JOINT FITTINGS BETWEEN MANHOLES - CONCRETE PIER SEE 1 /02D-03 I . STEEL PIPE SHALL BE EITHER SPIRAL WELDED OR SMOOTH WALL SEAMLESS WITH A MINIMUM YIELD STRENGTH OF 35,000 PSI. PAINTING AND LINING SHALL BE AS REQUIRED BY THE CITY 2. DUCTILE IRON PIPE SHALL BE SUPPORTED WITH TWO SPIDERS AT EVERY JOINT WITHIN THE CA51NG PIPE USING APPROVED PIPE ALIGNMENT GUIDE. SEE 5/02D-03. ALL JOINTS SHALL BE RESTRAINED JOINT. SEE 4/02D-02. 3. SUPPORT TYPE FOR PIERS SHALL BE DETERMINED BY ENGINEER BASED ON 5UBGRADE CONDITIONS AT SITE. SEE 3/02D-03 FOR 5UBGRADE PARAMETERS FOR EACH TYPE OF FOUNDATION. SEE 2/02D-02 FOR SUPPORTS PLACED WITHIN STREAM. 4. BOTTOM OF PIPE TO BE AT A MINIMUM OF I' ABOVE THE 25 YEAR FLOOD ELEVATION. STEEL CASING PIPE ELEVATION NOT TO SCALE COVER = MIN WT 147 LBS FRAME = MIN WT 220 LBS 2° 4 A ASTM A48-CL35 AASHTO M306 5/8" LETTERING RECESSED FLUSH 1" SPECIAL LETTERING RECESSED FLUSH n -23 1/2" :2:I CORED 9/16 " r 1 1/B " - HOL E (TYP) 1/4 J 1 7/8" 1/8" 20 1/2" 3/4" DETAIL m (1) 1 1/4" VENT HOLE PLAN VIEW 5/8" LETTERING RECESSED FLUSH 25 1/4" 23 3/4 " 3/4 " 23 1/2 " 25" 33" SEC7ION A -A 1" CORED HOLE (TYP) NOTES: ALL DIMENSIONS AND TOLERANCES ARE TO BE CONCENTRIC AND WILL SUPERSEDE ANY ASTM STANDARDS WITH A MAXIMUM VARIATION t 1/16" ON ALL DIMENSIONS. MANHOLE RING TO BE ANCHORED WITH 1/2" REDHEAD STAINLESS STEEL ANCHORS AND SEALED BETWEEN RING AND CONE WITH BITUMASTIC SEALER. ♦ MACHINED BEARING SURFACE 9 C/ T Y OF G R E E N S B O R O STD. NO. REV. STANDARD MANHOLE RING AND COVER 205 12-05 06-13 MIN EXISTING GRADE STEEL CA51NG PIPE PIPE ALIGNMENT GUIDE LOCATED AT EACH JOINT, 5EE 5/02D-03 PIPE JOINT, TYP NON -SHRINK DIP CARRIER PIPE GROUT PLUG, STANDARD HE 5/02D-03 MANHOLE 3/4" 5TAINLE55 STEEL ANCHOR BOLTS S STRAPS SECTION EXISTING GRADE -i STEEL CA51NG PIPE I=, I I- RJ DIP CARRIER PIPE STANDARD , MANHOLE PIPE SUPPORT, 3/4" 5TAINLE55 STEEL SEE 3/02D-03 ANCHOR 5OLT5 4 STRAPS ELEVATION TYPICAL PIPE SECTION & ELEVATION NOT TO SCALE HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1200 Charlotte, INC 28202-2075 704.338.6700 A 3 1/2" FLAT FACE GOTHIC IF 7 5/8 REQUIRED 1 3/4 6 7/8 ® 1 rrT c� 6 D 6 ��n� iN us 13 FLAT FACE A � GUTHIC TOP VIEW 1 3/4 �6 3/4� 10 3/4 SECTION A -A VIEW OF VALVE BOX SECTION VIEW OF VALVE BOX COVER NO TES: 1. VA VE BOX EXTENSION SHALL BE E/THER 6" DIA. SOIL PIPE OR SCH. 40 PVC PIPE. 2 EXTENSION TO BE ONE SOLID PIECE OF PIPE UNLESS BURIAL DEPTYH IS GREATER THAN STANDARD LENGTH OF PIPE. A BELL OR COUPLING SHALL BE UTILIZED AT THE TOP OF VALVE CONNECTION (SEE COG STD 09101) J. LETTER HEIGHT 3-1/2- 4. COUNTERSINK LETTER 3/16" 5. TO BE USED IN PAVED OR NON -PA VED AREAS 6. ALL CASTINGS SHALL MEET THE REQUIREMENTS OF AASHTO Ill 7. DUE TO VARIATIONS IN CASTINGS OF DIFFERENT MANUFACTURERS DIMENSIONS SHALL BE WITHIN REASONABLE TOLERANCES AS PRE -APPROVED BY GREENSBORO WATER RESOURCES DEPARTMENT AND/OR FIELD INSPECTOR PRIOR TO INSTALLATION. 8. VALVE BOX MAY BE REQUIRED TO BE 'VADE IN U.S.A." IF FEDERAL FUNDS ARE INVOLVED C/ T Y OF ORE ENS B O R O STD. NO.f08-02 REV. WATER VALVE BOX AND EXTENSION 1 0 2 3-93 03-12 12-12 9-10 - NOTES.' CONCRETE SHALL BE CLASS AA, 4000 PSI AS PER ASTM C-478. STEEL REINFORCING SHALL MEET ASTM C-185 (4" DIA) OR ASTM C-478 (5" DIA) . MANHOLES OVER 3'-6" IN DEPTH SHALL BE PROVIDED WITH STEPS 16" ON CENTERS. STEPS SHALL BE IN ACCORDANCE WITH COG STD. #206. ON NEW INSTALLATION A MAXIMUM OF (2) GRADE RINGS CAN BE USED. FOR FORCE MAINS LESS THAN 12" IN DIAMETER USE ROCKWELL SERVICE SADDLE 323, FORD, MUELLER, OR EQUAL. ALL PIPE TO BE MINIMUM 2" 315 STAINLESS STEEL ALLOY AND NIPPLES TO BE 2" 316 STAINLESS STEEL ALLOY. MANHOLE INTERIOR SHALL RECEIVE TWO COATS OF SHERWIN WILLIAMS SHER—FLEX OR APPROVED EQUAL WITH A TOTAL DRY FILM THICKNESS OF 80-125 MILS. COG STD. #205 OR #205-A RING 6 COVER 00 '-` 5'-0I.D. ` •=i g MIN 18" .1 $ ALIGN AIR RELEASE • SHUT OFF VALVEWITH .� Z E OF GFOR '• MANHOLE _- EASY HJVEU � O I 2 CRISPIN UNIVERSAL BA MODEL N0. US20B`= (OR EQUAL) 2" AIR RELEASE VAL VE W/_ 1/8" ORIFICE. UNIT_ HAS SCREWED INLET _ W/ BACKFL USH. NI-' I 2 " WN j ---. GA TE(T2" 315 STAINLESS 22„ STEEL ALLOY OFFSET 2" CORP. STOP SEWER FORCE MAIN CC THREAD X FIP THREAD OUTLET 4 PLACE 12" OF 057 T. ' STONE UNDER BASE T 6'-10" STD. #201 SECTION THRU MA NHOL E ClT Y OF G R E E N S B O R O AIR RELIEF VALVE WITH ASSEMBLY STD. NO. REV. 211 03-03 03-22 0s-08 AND MANHOLE FOR SANITARY SEWER LINES 03-08 SEE NOTE 4 FOR BAR 512E AND SPACING E /4"x3" 5TAINLE55 STEEL STRAP WITH /4"x2 1/2" NEOPRENE PAD ADHERED TO STRAP (5EE NOTE 5) I/4"xG" NEOPRENE PAD ADHERED TO SADDLE CA51NG PE DIA. "D" (IN.) H" (FT.) THICKNESS "A" (IN.) PIER WIDTH "B" (FT.) FOOTING LENGTH "C" (FT.) FOOTING WIDTH "D" (FT.) G 12 2'-4" 5'-G" 3'-0" 8 12 2'-4" G'-3" 3'-0" G- 2 10 12 2'-4" G'-8" 3'-0' 12 12 2'-4" 7-2" 3'-0" < G 12 3'-0" 8'-0" 3'-0" 14-20 8 12 3'-0" 9'-0" 3'-0" 10 12 3'-0" 9'- 10" 3'-C" 2 14 3'-0" 1O'-G" 3'-0" < G 14 3'-8" 8'-9" 4'-0" 8 14 3'-8" 101_0" 4'-0" 22-26 0 14 3'-6" 11'-0" 4'-0" 2 14 3'-8" I I' -loll 4'-0" < G 18 4'-4" 9'-0" 4'-0" 8 18 4'-4" 0'-G" 4'-0" 30-3G 10 18 4'-4" 1 G" 4'-0" 12 18 4-4" 2'-4" 4'-0" < G 18 R-4" 38-48 10 18 R-4' 2'-0" 5-0" 12 18 R-4" 1 2'-10'' 5'-0" 5 1-56 5 G 18 G'-4" 91- l oll 5'-C" 8 18 G'_4" 11'-4" 5-0" 10 18 G'_4" 12'-4" 5'-0" 12 18 G'-4" 13-2' 5'-0" CONCRETE PIER DETAIL NOT TO SCALE SNUG FIT 314" 0 5TAINLE55 STEEL ANCHOR 5OLT5, A5TM A307 OR A3G BEE NOTE 4 FOR BAR SIZE AND SPACING I I NOTE5: I C I NOTES: 5HALLOW FOUNDATION DESIGN SHOWN ON THI5 DETAIL 15 BA5ED ON THE FOLLOWING PARAMETERS: ALLOWABLE SOIL BEARING CAPACITY = 2000 P5F CONCRETE COMFRE551VE 5TPENGTH = 4000 P51 GRADE GO REINFORCING STEEL MAXIMUM STREAM VELOCITY - 10 FT/5EC MAXIMUM SUPPORT HEIGHT (H) = 1 2'-0' IF FIELD CONDITIONS REQUIRE ANY DEVIATION FROM THE5E PARAMETERS, THE FOUNDATION DESIGN SHALL BE REVIEWED BY THE ENGINEER. 2. IF 50GRADE AT LOCATION OF SUPPORTS 15 DEEMED UNABLE TO WITHSTAND 2000 P5F BEARING PRESSURE, A PILE SUPPORTED FOUNDATION SHALL BE UTILIZED A5 PER 3/02D-03. 3. IF BEDROCK 15 ENCOUNTERED WHICH WILL PREVENT 3-FEET MINIMUM COVER OVER FOOTING, DOWELS SHALL BE DRILLED INTO BEDROCK PRIOR TO PLACING FOUNDATION. 5EE 4/02D-03. 4. TWELVE -INCH AND FOURTEEN -INCH THICK PIERS AND FOOTINGS SHALL BE REINFORCED WITH #5 BARS AT 12 INCHES OC IN EACH DIRECTION ON EACH FACE. EIGHTEEN -INCH WIDE FIER5 AND FOOTINGS SHALL BE REINFORCED WITH #7 BAR5 AT 12 INCHES OC IN EACH DIRECTION ON EACH FACE. 5. EIGHTEEN -INCH THICK FIER5 5hALL REQUIRE TWO STRAPS OVER THE PIPE INSTEAD OF ONE (A5 SHOWN). G. WHEN CONCRETE SUPPORTS ARE REQUIRED TO BE LOCATED WITHIN A STREAM AND ARE NOT COVERED WITH BACKFILL, SEE G/02D-03 FOR MODIFICATIONS TO UPSTREAM FACE OF SUPPORT. 1/4"x3" 5TAINLE55 STEEL STRAP WITH 1/4"x2 112" NEOPRENE FAD ADHERED TO STRAP (5EE NOTE 4) 1/4"xG" NEOPRENE PAD ADHERED To sADDLF D 3/4" o 5TAINLE55 T v RUBBER END SEAL WRAP FINISHED GRADE STEEL ANCHOR BOLTS, N 120° � ASTM A307 OR A3G 5EE NOTE 3 FOR BAR SIZE AND SPACING HP12x53 STEEL FOR PILE SPLICE, SEE G/C2D-C3 NOTES: 1. PILE SUPPORTED PIER FOUNDATION DE51GN SHOWN ON THI5 DETAIL 15 5A5ED ON THE FOLLOWING PARAMETERS: MINIMUM CAPACITY OF HP 12x53 PILE = 30 TON5 CONCRETE COMPPE551VE STRENGTH = 4000 P51 GRADE GO REINFORCING STEEL MAXIMUM STREAM VELOCITY = 10 7/5EC IF FIELD CONDITIONS REQUIRE ANY DEVIATION FROM THE5E PARAMETERS, THE FOUNDATION DESIGN SHALL BE REVIEWED BY THE ENGINEER. 2. LENGTH OF PILES SHALL BE A5 REQUIRED TO DEVELOP 30 TON CAPACITY BY EITHER END BEARING, FRICTION OR A COMBINATION OF END BEARING AND FRICTION. A5 A MINIMUM, PILES SHALL BE DRIVEN AT LEAST 15 FEET INTO UNDISTURBED 501 L. 3. TWELVE -INCH AND FOURTEEN -INCH WIDE FIER5 SHALL BE REINFORCED WITH #5 BARS AT 12 INCHES OC IN EACH DIRECTION ON EACH FACE. EIGHTEEN -INCH WIDE PIERS SHALL BE REINFORCED WITH #7 BARB AT 12 INCHES OC IN EACH DIRECTION ON EACH FACE. FOOTINGS SHALL BE REINFORCED TYPICALLY TO FIER5. 4. EIGHTEEN -INCH WIDE PIERS SHALL REQUIRE TWO STRAPS OVER THE PIPE INSTEAD OF ONE (A5 5HOWN). 5, WHEN CONCRETE SUPPORTS ARE REQUIRED TO BE LOCATED WITHIN A STREAM AND ARE NOT COVERED WITH BACKFILL, SEE G/02D-03 FOR MODIFICATIONS TO UPSTREAM FACE OF SUPPORT, 3 IZE NG CA51NG PIPE DIA. "D" (IN.) PIER THICKNESS "A" (IN.) FOOTING THICKNE55 B" (IN.) PIER WIDTH "C" (FT.) FOOTING WIDTH D" (FT.) FOOTING LENGTH E" (FT.) FILE SPACING Fl (FT.) G- 12 12 20 2'-4" 3'-0" 0-0" 3'-0" 14-20 12 20 3'-0" 3'-0" 8'-0" 5'-0" 22-26 18 2G 3'-8" 4'-0" 8'-9" 5'-9" 30-3G 18 2G 4'-4" 38-46 18 2G 5'-4" 5'-0" 9'-G" G'-G" 5 1-GO 18 2G G'-4" 5'-0" 9'-1oll G'- 10" PILE PIER SUPPORTED DETAIL NOT TO SCALE NORMAL THICKNES 5EE NOTE CONCRET LEVELING BE PLACE FOOTING C9 cV G" 1211 #7 BARS AROUND COMPETENT w I- 0 z w SEE NOTE I NOTES: I . GEOMETRY OF FOOTING SHALL MATCH GEOMETRY OF CONCRETE PIERS WITH HEIGHT OF G FEET OR LE55 A5 PER 1 /02D-03. 2. NON -SHRINK GROUT SHALL BE "EUCO-N-S" BY THE EUCLID CHEMICAL COMPANY; "MASTERFLOW 713" BY MASTER BULDERS, OR EQUAL. CONCRETE PIER ON BEDROCK NOT TO SCALE STEEL CASING PIPE PVC CARRIER PIPE CARRIER PIPE 3/8" STEEL PLATE, TYP 3/811x4" STEEL PLATE, TYP 5/8" 0 A325 BOLT CASING PIPE 3/ I G V 4 1 " R ON ALL CORNERS NOTE: NON -SHRINK GROUT SHALL BE "EUCO-N-5" BY THE EUCLID CHEMICAL COMPANY; "MASTEPFLOW 713" BY MASTER BUILDERS, OR EQUAL. TYPICAL CASING PIPE WRAP NOTE: USE A MINIMUM OF 2 SPIDERS PER JOINT PLACED I ONE FOURTH OF THE PIPE JOINT LENGTH IN FROM BOTH THE BELL AND SPIGOT, PIPE ALIGNMENT GUIDE CASING PIPE DETAILS NOT TO SCALE #3 STIRF #3 STIRF BELOW F (BEYONL HP 12x5: STEEL PI WIDTH OF PILE CAP CA51NG PIPE DIAMETER (IN.) TOTAL WIDTH "A" (FT.) PILE SPACING "B" (FT.) < 3G G'-0" 3'-0" 36-42 G-G" 3'-G" 45-51 T-3" 4'-3" 54-GO 8'-0" 5'-0" PILE CAP DETAIL NOT TO SCALE "'2-1 /4"x3" STRAPS WITI1 /411x2 112" NEOPRENE PAD ADHERED TO STRAP — 1/4"xG" NEOPRENE PAD ADHERED TO SADDLE *" 3/4" ANCHOR BOLTS ASTM A307 OR A3G N o ztim m 53 3 'ILE E SPLICE, )2D-03 8" 120' SNUG FIT #3 STIRRUPS @ G" TYP 4-#4, TYP 4-#4 4-#7 1 3 #3 CIRCULAR HOOPS, TYP B 8" A NOTES: I . PILE SUPPORTED FOUNDATION DESIGN SHOWN ON THIS DETAIL IS BASED UPON THE FOLLOWING PARAMETERS: MINIMUM CAPACITY OF HP 12x53 PILE = 30 TONS CONCRETE COMPRESSIVE STRENGTH = 4000 PSI GRADE GO REINFORCING STEEL MAXIMUM STREAM VELOCITY = 10 FT/SEC IF FIELD CONDITIONS REQUIRE ANY DEVIATION FROM THESE PARAMETERS, FOUNDATION DESIGN SHALL BE REVIEWED BY THE PROJECT ENGINEER. 2. LENGTH OF PILES SHALL BE A5 REQUIRED TO DEVELOP 30 TON CAPACITY BY EITHER END BEARING, FRICTION OR A COMBINATION OF END BEARING AND FRICTION. AS A MINIMUM, PILES SHALL BE DRIVEN AT LEAST 15 FEET INTO UNDISTURBED SOIL. '`3. ANCHOR BOLTS AND STRAPS SHALL BE STAINLESS STEEL. DETAIL B GO LT�< DETAIL A L�J 45° COLUMN VERTICAL COLUMN HORIZONTAL OR VERTICAL o GO, + 10° x o 0" TO 1 /8" _Oo v� \ 3 — T )pi- 03/4"MAX 00O DETAIL A DETAIL B o POSITION OF COLUMN DURING WELDING STEEL PILE SPLICE B A/2 12" UPSTREAM FACE C ® ch ADDITIONAL #4@ 1211 ADDITIONAL VERTICAL BAR, SAME SIZE A5 OTHERS PLAN - CONCRETE SUPPORT NOSING (WHEN EXPOSED TO STREAM FLOW) CONCRETE SUPPORT DETAILS NOT TO SCALE HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1200 Charlotte, NC 28202-2075 704.338.6700 1 I G11 Q1p K 1 /2" S ATE STRAI TYP 1 1 /2" �" O X 4" NUTS (TY 1 /2" TF X 4"X 1/ c I nr\. (SHOE —BEND ENDS UP 1 /2") CASING SECTION END ELEVATION USE RACI° HDPE SPACERS, TYPE G. IN LIEU OF STEEL SPACERS WHERE INDICATED ON DRAWINGS. STEEL SPIDER DETAIL NOT TO SCALE STD WT STL PIPE SLEEVE, GALV AFTER FABRICATION ANNULAR SEAL PIPE THRU WALL OR FLOOR PIPE THRU WALL OR FLOOR d AS RECOMMENDED ' BY ANNULAR SEAL d o v MANUFACTURER ANNULAR LINK -SEAL PROVIDE SINGLE ROW OF SEALS FOR PIPES d o LESS THAN 16" DIA. PROVIDE DOUBLE ROW OF SEALS FOR PIPES 16" DIA AND LARGER. d WALL SLEEVE d v T/2 AS RECOMMENDED I BY ANNULAR 1/4"x3" STEEL P L T SEAL MFR SEEP RING '— 8" INTERIOR, DRY T/2 BURIED, WET OR NOTE: TYPICAL PENETRATION OF BURIED DIP THROUGH OR TOP SIDE T�$„ BOTTOM SIDE CONCRETE PRECAST STRUCTURE UNLESS OTHERWISE ►� INDICATED. PENETRATION THROUGH PRECAST CONCRETE DETAIL NOT TO SCALE 12'-0" MAXIMUM BETWEEN SPACERS CASING SPACERS SHALL BE SPACED A MAXIMUM OF V-6" FROM EACH SIDE OF JOINT INSTALL THREE CASING SPACERS PER PIPE JOINT AS REQUIRED TO MEET MAXIMUM SPACING V-6" (MAX: 6" (MIN) 1'-0" PLUG STEEL CASING PIPE CASING END PLUGS 1. CASING SHALL BE PLUGGED ON BOTH ENDS BEFORE BACKFILLING. PLUGS SHALL CONSIST OF MINIMUM OF 1 LINEAR FOOT OF LOW STRENGTH GROUT (1,500 PSI MIN). 2. PROVIDE SIX-1/2" DIAMETER WEEP HOLES ON DOWNSLOPE SIDE OF CASING. TYPICAL PIPE CROSSING NOT TO SCALE GENERAL NOTES: 1. UNLESS OTHERWISE SPECIFIED, ALL HARDWARE SHALL BE 316 STAINLESS STEEL OR BETTER. HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1200 Charlotte, NC 28202-2075 704.338.6700