LETTER OF APPROVAL WITH MODIFICATIONS
Town of Wingate
Attention: Brad Sellers, Town Manager
Post Office Box 367
Wingate,North Carolina 28174
RE: Project Name: Main Street Water Line Extension
Acres Approved: 3.3
Project ID: UNION-2024-009
County: Union, City: Wingate
Address: Main Street
River Basin: Yadkin-PeeDee
Stream Classification: Other
Submitted By: John Grey, PE, Wooten
Date Received by LQS: February 22, 2024
Plan Type: Revised
Dear Mr. Sellers:
This office has reviewed the subject erosion and sedimentation control plan. We find the plan to be acceptable
with modifications and hereby issue this letter of Approval with Modifications. The Modifications Required for
Approval are listed on the attached page. This plan approval shall expire three (3) years following the date of
approval, if no land-disturbing activity has been undertaken, as is required by Title 15A NCAC 4B .0129.
As of April 1, 2019, all new construction activities are required to complete and submit an electronic Notice of
Intent (eNOI) form requesting a Certificate of Coverage (COC) under the NCG010000 Construction General
Permit. After the form is reviewed and found to be complete, you will receive a link with payment instructions
for the $120 annual permit fee. After the fee is processed, you will receive the COC via email. As the
Financially Responsible Party shown on the FRO form submitted for this project, you MUST obtain the COC
prior to commencement of any land disturbing activity. The eNOI form may be accessed
at deq.nc.gov/NCG01. Please direct questions about the eNO1 form to the Stormwater Program staff in the
Raleigh central office. If the owner/operator of this project changes in the future, the new responsible
party must obtain a new COC.
Title 15A NCAC 4B .0118(a) and the NCGO1 permit require that the following documentation be kept on file
at the job site:
1. The approved E&SC plan as well as any approved deviation.
D_E North Carolina Department of Environmental Quality I Division of Energy,Mineral and Land Resources
�l Mooresville Regional Office 1610 East Center Avenue,Suite 301 I Mooresville,North Carolina 28115
704-663-1699
DocuSign Envelope ID:746DC5A9-DDDB-4CC8-943F-52C79EA1DDEB
Letter of Approval with Modifications
Town of Wingate
November 21, 2023
Page 2 of 3
2. The NCGO1 permit and the COC, once it is received.
3. Records of inspections made during the previous 30 days.
Also, this letter gives the notice required by G.S. 113A-61.1(a) of our right of periodic inspection to ensure
compliance with the approved plan.
North Carolina's Sedimentation Pollution Control Act is performance-oriented, requiring protection of existing
natural resources and adjoining properties. If, following the commencement of this project, it is determined that
the erosion and sedimentation control plan is inadequate to meet the requirements of the Sedimentation Pollution
Control Act of 1973 (North Carolina General Statute 113A-51 through 66), this office may require revisions to
the plan and implementation of the revisions to ensure compliance with the Act.
Acceptance and approval of this plan is conditioned upon your compliance with Federal and State water quality
laws, regulations, and rules. In addition, local city or county ordinances or rules may also apply to this land-
disturbing activity. This approval does not supersede any other permit or approval.
Please note that this approval is based in part on the accuracy of the information provided in the Financial
Responsibility Form, which you provided. You are requested to file an amended form if there is any change in
the information included on the form. In addition, it would be helpful if you notified this office of the proposed
starting date for this project.
Your cooperation is appreciated.
Sincerely,
EDocuSigned by:
gO-c4010.1i art,vvO W
70735F9D3B774C3...
Ben Garrow
Assistant Regional Engineer
Land Quality Section
Enclosures: Certificate of Approval
Modifications Required for Approval
NCGO1 Fact Sheet
c: Inspection Department
ec: John Grey, PE
DocuSign Envelope ID:746DC5A9-DDDB-4CC8-943F-52C79EA1DDEB
Letter of Approval with Modifications
Town of Wingate
November 21, 2023
Page 3 of 3
MODIFICATIONS REQUIRED FOR APPROVAL
Project Name: Main Street Water Line Extension
Project ID: UNION-2024-009
County: Union
1. Adequate measures(e.g. silt fence, straw wattles,etc.)shall be provided below all proposed land disturbance
activities where disturbed areas flow towards property owned by others and/or streams/drainage channels.
In some locations, there are no proposed measures located below the land disturbance activity to contain
sediment. Some examples are: Sheet C-1.01 from STA 10+50 to near STA 11+40. Sheet C-1.02 on South
side of N. Camden Rd. and North side of McIntyre Rd. Sheet C-1.03 from STA 38+00 to near STA 39+75.
Sheet C-1.05 North of STA 75+96. Adequate inlet protection shall be provided for drop/yard inlets and/or
open pipe inlets which receive runoff from disturbed areas.
2. Response letter indicated design calculations were attached, however, the design calculations were not
received. Provide design calculations for stabilization of ditch lines located throughout the site. Ditch lines
with a velocity of 2 fps or greater require a temporary liner. Ensure the permissible velocity in grass lined
channels are not exceeded. Ensure the type of liner to be installed is identified(e.g.NAG S75, Curlex 1, or
approved equal, etc.). This information must be provided to this office prior to the start of land disturbance
activities.
3. Sheet C-1.03 Comments: The line installation at STA 46+60 will cross a stream. All line installation must
be conducted in the dry. Provide the minimum temporary culvert size necessary to convey bank-full flow
and an adequate construction sequence of how all work will be conducted in the dry. Ensure stream channel
is properly stabilized prior to removing coffer dam and temporary culvert. An adequate outlet in the silt
fence must be provided where silt fence is shown crossing the existing ditch line near STA 47+60. In
addition, adequate channel stabilization must be provided where runoff from storm drainage system flows
across LOD near STA 47+60 to STA 48+20. The minimum temporary stream culvert and construction
sequence must be provided to this office prior to the start of land disturbance activities. The print quality
of Detail#7 (Sheet C-2.02) is barely visible for some areas. Ensure print is clearly visible.
4. Sheet C-1.04 Comments: An adequate outlet in the silt fence must be provided where silt fence is shown
crossing the swale area near STA 52+50. Provide excavated storage area as needed upstream of the silt
fence outlet. Provide adequate outlet protection below the culvert outlet from the road.