Loading...
HomeMy WebLinkAboutNCG140143 DMR WW (6)PROCESS WASTEWATER .. Quarterly Discharge Monitoring Report GENERAL PERMIT -No. NCG140000 CERTIFICATE OF COVERAGE NO. NCG140143 SAMPLE COLLECTION -YEAR: 2014 ..FACILITY NAME: King 7SAMPLE QUARTER:_- QJul-Sept ZOct=Dec QJan-March QApril-June PERSON COLLECTING SAMPLES:.Tony-Hardison�y -COUNTY: Forsyth _ CERTIFIED_ LABORATORY:. Research & Analytical Lab # 34. ECEIV QNENO, (704)-372-2930 201DD TO LISTSERVEi [+YES ZNO EMAIL: JAN 2.0 LIMIT VIOLATIONS? YES 0 NO Z DISCHARGING TO CLASS: []SA- ❑HQW ❑PNA [Trout ®Other CENTRAL- EILEOPTIONAL INFO: Part A: wastewater iviomtormg requirements Date Sample ;4TotafSuspended 1 Typeof Wastewatek pH .. r Outfall No.- Collected = z Solids " (VE, RM, MD) (standard) (mm%dd/yr) TPH using 'Settleable ' meiliod.1664A Solids 6 : sK " 4 SGT_ -HEM ,(mg/L) Discharge Duration " (minutes) .` Total Flow 7. (gallons/day). r :. ;RM MD 6-93 4., ^.303 5 53 (15)e 001: 12/22/2014 RM,----. No Flow -: 002 12/22/2014 RM -No Flow ..._ I -wastewater systems nave not aiscnargea in tnis.quarter — report ivo riow . or ivo uiscnarge nere. Piease maKe sure to marK the sample quarter above. 2 Report the abbreviation f& -the type'of Authorized Wastewater Discharges here: Vehicle and Equipment Cleaning (VE), Raw Material Stockpiles_( RM Mixing -Drum Cleanout (MD). Report more than one type if the waste-stream,is commingled. 3If an.effluent limit is exceeded twice in -a row, the permittee is required to institute`monthlyrnonitoring for that parameter for six months, unless DWQ Rb staff notifies you to continue monitoring: 4pH limits are 6.9 S.U. for wastewater discharges to freshwaters, and 6.8-8.5 S.U. for discharges to saltwaters s TSS limits are 20 mg/Lfor wastewater discharges to HQW waters, 10 mg/L for Trout and PNA'waters, and_ 30 mg/L for all.other water, classifications. Permit Date: 7/1/2010-06/30/2015 Last Revised 07/13/11 Page 1 of 2 e Process wastewater discharges shall only be.monitored forTPH when commingled with stormwater discharges from VMA areas.,TPH does not have a limit for.wastewater, but instead is.subject to benchmarks'and provisions of Part-.IV, Section A, including the Tiered Response Action... ' Flow rate can be measured continuously or calculated. Flow limits for wastewater`discharges to HQW waters shall.be set to 50% of"the-Summer 7Q10 Flow.as per 15A NCAC 02B .0224. Permittees who discharge wastewater to HQW waters shall obtain a Summer 7Q10 flow and report-this information to DWQ. If the permittee cannot obtain a Summer 7Q10 flow for the receiving waters at the discharge location, the'permittee shall notify DWQ, and the'DWQ Regional Office may require an annual flow report on a case-by-case basis. MAIL ORIGINAL-AND ONE COPY OF THIS ANNUAL-SUMMARY (INCLUDING ALL "NO FLOW",-"NO DISCHARGE") WITHIN 30 DAYS OF RECEIPT OF SAMPLE (OR AT END OF MONITORING PERIOD- lIN CASE OF "NO FLOW") TO: Division of Water Quality Attn: DWQ.Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 (919)807-6379 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under'penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified ersonnel properly gather an&evaluate the information submitted. Based on my Inquiry. of the person or persons who manage the system, or those persons direct resp risible for gathering the information, the information submitted Is, to the best of my knowledge and belief, true, accurate,. and. complete. I am aware thatth a gnificant penalties for submitting false information, including the: possibility of fines and imprisonment for knowing violations." ignature f Permittee) (Date) Permit Date: 7/1/2010-06/30/2015 Last Revised 07/13/11 Page 2 of 2