HomeMy WebLinkAboutNCG140099 DMR WW (3)Ong - State
PROCESS WASTEWATER — Quarterly Discharge Monitoring Report 0 Copy - State
GENERAL PERMIT NO. NCG140000 0 Copy - Plant
0 Copy - File
a-Dt 5
CERTIFICATE OF COVERAGE NO. NCG14 0 0 9 9 SAMPLE COLLECTION YEAR-20118'-
FACILITY
EAR:2@918"FACILITY NAME: Chandler Concrete Company - Sparta #505 SAMPLE QUARTER: ®Jul -Sept ❑Oct -Dec ❑Jan -March ❑April -June
PERSON COLLECTING SAMPLES: -
CERTIFIED LABORATORY:Blue Ridge Labs Inc. Lab #275
-v- Ashe
RECE�F Ad AO. ( 336) 982 - 8760
NOV 0 JkQ 9110 LISTSERVE? []YES ®NO EMAIL:
LIMIT VIOLATIONS? YES ❑ NO ® DISCyygqRGING TO CLASS: ❑SA ❑HQW ❑PNA ❑Trout ®Other: C
TSS Exceedance - bank erosion from neighboring property crossi IATRAL FILES
property, heavy rains. Evaluating options. WFC SES
OPTIONAL INFO:
Part A: Wastewater Monitorine Reauirements
Date Sample
Outfall No. Collected)
(mm/dd/yr)
Type of Wastewater
VE, RM, MD 2
( )
Total Suspended
pH
Solids
(standard)
(
(mg/L)
Settleable
Solids
(mL/L)
TPH usingDischarge
method 1664A
6
(mg/L) SGT -HEM
Total Flow
Duration 7
(minutes) (gallons/day)
- -
-
6-93'4 3035
53
(15)6
1 JUL - NO FLOW
VE RM MD
N/A
1 AUG - NO FLOW
VE RM MD
N/A
1 SEP - NO FLOW
VE RM MD
N/A
No Qualifying Discharge observed this Period -
1 If wastewater systems have not discharged in this quarter — report "No Flow" or "No Discharge" here. Please make sure to mark the sample quarter above.
2 Report the abbreviation for the type of Authorized Wastewater Discharges here: Vehicle and Equipment Cleaning (VE), Raw Material Stockpiles (RM), Mixing Drum
Cleanout (MD). Report more than one type if the waste -stream is commingled.
3If an effluent limit is exceeded twice in a row, the permittee is required to institute monthly monitoring for that parameter for six months, unless DWQ RO staff
notifies you to continue monitoring.
4 pH limits are 6-9 S.U. for wastewater discharges to freshwaters, and 6.8-8.5 S.U. for discharges to saltwaters.
5 TSS limits are 20 mg/L for wastewater discharges to HQW waters, 10 mg/L for Trout and PNA waters, and 30 mg/L for all other water classifications.
6 Process wastewater discharges shall only be monitored for TPH when commingled with stormwater discharges from VMA areas. TPH does not have a limit for wastewater,
but instead is subject to benchmarks and provisions of Part IV, Section A, including the Tiered Response Action.
' Flow rate can be measured continuously or calculated. Flow limits for wastewater discharges to HQW waters shall be set to 50% of the Summer 7Q10 Flow as per 15A
NCAC 02B .0224. Permittees who discharge wastewater to HQW waters shall obtain a Summer 7Q10 flow and report this information to DWQ. If the permittee cannot
obtain a Summer 7Q10 flow for the receiving waters at the discharge location, the permittee shall notify DWQ, and the DWQ Regional Office may require an annual flow
report on a case-by-case basis.
Permit Date: 7/1/2010-06/30/2016
Last Revised 07/13/11
Page 1 of 2
MAIL ORIGINAL AND ONE COPY OF THIS ANNUAL SUMMARY (INCLUDING ALL "NO FLOW", "NO DISCHARGE") WITHIN 30 DAYS OF RECEIPT OF SAMPLE (OR
AT END OF MONITORING PERIOD IN CASE OF "NO FLOW") TO:
Division of Water Quality
Attn: DWQ Central Files
1617 Mail Service Center
Raleigh, North Carolina 27699-1617
(919) 807-6379
Sediment basins were cleared and erosion from adjacent property controlled using hay bales —151 of 3 monthly samples within specifications for TSS.
We continue to monitor controls.
No qualifying discharge in:
• JANUARY 2015 / FEBRUARY 2015 / MARCH 2015
• APRIL 2015 / MAY 2015 / JUNE 2015
Monthly monitoring could not be performed during this period due to no discharge. We
will continue to monitor and submit reports in the event of a qualifying discharge.
YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED:
"I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to
assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or
those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and
complete. I am aware th here re sign' icant penalties for submitting false information, including the possibility of fines and imprisonment for knowing
violations."
%d 9J
(ignatu o Permittee) (D e)
Permit Date: 7/1/2010-06/30/2016 Last Revised 07/13/11