Loading...
HomeMy WebLinkAboutSW4240202_Supplement-EZ Form_20240617 DRAINAGE AREAS r 1 Is this a high density project? Yes 2 If so,number of drainage areas/SCMs 1 3 Does this project have low density areas? Yes 4 If so,number of low density drainage areas 1 Is all/part of this project subject to previous rule 5 versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site 1 LD 1 4 Type of SCM SAND FILTER 5 Total drainage area(sq ft) 183312 72189 111123 6 Onsite drainage area(sq ft) 183312 72189 111123 7 Offsite drainage area(sq ft) 0 0 0 8 Total BUA in project(sq ft) 75399 sf 72189 sf 3210 sf New BUA on subdivided lots(subject to permitting) 9 (sq ft) Sf sf sf New BUA not on subdivided lots(subject to 10 permitting)(sf) sf sf sf 11 Offsite BUA(sq ft) sf sf sf 12 Breakdown of new BUA not on subdivided lots: -Parking(sq ft) _ 51292 Sf 48082 sf 3210 Sf -Sidewalk(sq ft) 487 sf 487 sf sf -Roof(sq ft) 23620 Sf 23620 sf sf -Roadway(sq ft) 20235 sf sf sf -Future(sq ft) Sf sf Sf -Other,please specify in the comment box below(sq ft) sf sf sf New infiltrating permeable pavement on 13 subdivided lots(sq ft) Sf sf Sf New infiltrating permeable pavement not on 14 subdivided lots(sq ft) sf sf sf Existing BUA that will remain(not subject to 15 permitting)(sq ft) 15538 Sf sf 15538 Sf 16 Existing BUA that is already permitted(sq ft) sf sf sf 17 Existing BUA that will be removed(sq ft) Sf sf Sf 18 Percent BUA 41% 100% 3% 19 Design storm(inches) 1.0 in 20 Design volume of SCM(cu ft) 5725 cf 21 Calculation method for design volume SHULER ADDITIONAL INFORMATION Please use this space to provide any additional information about the 22 drainage area(s): HD area contains Buildings,Parking,and Sidwalk directed into the Sand Filter.The LD area is directed around the site.The parcel overlaps existing roads and drives.These areas are Existing BUA that will remain and is not subject to permiting.Except for small parking entrance area. SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION 1 Project Name Twin Oaks Landscaping 2 Project Area(ac) 4.208 3 Coastal Wetland Area(ac) 0 4 Surface Water Area(ac) 0 5 Is this project High or Low Density? Both High and Low Density 6 Does this project use an off-site SCM? No COMPLIANCE WITH 02H.1003(4) 7 Width of vegetated setbacks provided(feet) N/A 8 Will the vegetated setback remain vegetated? N/A 9 If BUA is proposed in the setback,does it meet NCAC 02H.1003(4)(c-d)? N/A 10 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: 11 Infiltration System 12 Bioretention Cell 13 Wet Pond 14 Stormwater Wetland 15 Permeable Pavement 16 Sand Filter 1 17 Rainwater Harvesting(RWH) 18 Green Roof 19 Level Spreader-Filter Strip(LS-FS) 20 Disconnected Impervious Surface(DIS) 121 Treatment Swale 22 Dry Pond 23 StormFilter 24 Silva Cell 25 Bayfilter 26 Filterra FORMS LOADED DESIGNER CERTIFICATION 27 Name and Title: Max Prestwood III,PE-Project Engineer 28 Organization: BREC,PA 29 Street address: 1520 Meadowview Drive 30 City,State,Zip: Wilkesboro,NC 28697 31 Phone number(s): (336)844-4088 32 Email: max@brec.biz Certification Statement: I certify,under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision;that the information provided in the form is,to the best of my knowledge and belief,true,accurate,and complete;and that the engineering plans, specifications,operation and maintenance agreements and other supporting information are consistent with the information provided here. Designer Signature of Designer Sea/ Date LOW DENSITY DESIGN REQUIREMENTS FOR LOW DENSITY PROJECTS FROM 02H.1003 1 Is project below density thresholds set forth in the applicable stormwater rule? Yes 2 Does project maximize dispersed flow and minimize channelization of flow? Yes 3 Has the use of piping been minimized per.1003(2)(c)? Yes 4 Side slopes of the vegetated conveyances(H:V) 3:1 5 Maximum velocity in the vegetated conveyances during the 10-year storm? 2.94 6 Are curb outlet swales proposed? No 7 Maximum longitudinal slope of curb outlet swale(s)(%) 8 Bottom width of curb outlet swale(s)(feet) 9 Maximum side slope of curb outlet swale(s)(H:V) 10 Minimum length of curb outlet swale(s)(feet) 11 Are treatment swales used instead of curb outlet swales? 12 Is stormwater released at the edge of the setback as dispersed flow? Yes 13 Have stormwater outlets been designed to prevent downslope erosion? Yes 14 Are variations to rule.1003 proposed? No ADDITIONAL INFORMATION 15 Please use this space to provide any additional information about this low density project: Even though exsithing BUA is not subject to permiting,it was used for the following flow calculations Drainage Pervious Swale Area BUA area C Q Slope Vanaw V, Flow depth # (ac) (ac) (ac) (cfs) (%) (fps) (fps) (ft) 1 0.73 1153.00 30692.60 0.20 0.84 1.29% 4.50 1.77 0.21 2 0.26 0.00 11468.90 I 0.20 0.35 1.26% 4.50 1.35 0.14 3 0.26 0.00 11468.90 0.20 0.35 4.79% 4.50 2.41 0.12 4 0.49 0.00 21487.10 0.20 0.50 1.27% 4.50 1.81 0.24 5 1.01 8357.00 35624.80 0.45 1.10 2.41% 4.50 2.94 0.31 6 1.42 15547.00 46433.80 0.39 2.54 0.79% 4.50 1.99 0.39 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 SAND FILTER r 1 Drainage area number 1 2 Minimum required treatment volume(cu ft 4293 sf GENERAL MDC FROM 02H.1050 3 Is the SCM sized to treat the SW from all surfaces at build-out? Ye& 4 Is the SCM located away from contaminated soils? Yes 5 What are the side slopes of the SCM(H:V)? N/A _ 6 Does the SCM have retaining walls,gabion walls or other engineered Yes side slopes? 7 Are the inlets,outlets,and receiving stream protected from erosion Yes (10-year storm)? 8 Is there an overflow or bypass for inflow volume in excess of the Yes design volume? _ 9 What is the method for dewatering the SCM for maintenance? Pump(preferred)_ 10 If applicable,will the SCM be cleaned out after construction? Yes 11 Does the maintenance access comply with General MDC(8)? Yes 12 Does the drainage easement comply with General MDC(9)? Yes 13 If the SCM is on a single family lot,does(will?)the plat comply with N/A General MDC(10)? 14 Is there an O&M Agreement that complies with General MDC(11)? Yes 15 Is there an O&M Plan that complies with General MDC(12)? Yes 16 Does the SCM follow the device specific MDC? Yes 17 Was the SCM desi ned b an NC licensed rofessional? Yes SAND FILTER MDC FROM 02H.1056 18 SHWT elevation(fmsl) _ 3065.00 19 Type of sand filter(open or closed) _ Closed 20 If closed,will the filter will be pre-cast or pour-in-place? _ Pre Cast 21 If closed,top of grate elevation(fmsl) 3079.97 22 Is this sand filter designed to attenuate peak flows? T No Sediment Chamber 23 Volume that can be retained in the sediment chamber(cubic feet) 2928 cf 24 Will there be a permanent pool in the sediment chamber? Yes 25 Bottom of the sediment chamber(fmsl) 3069.53 _ 26 Area of the sediment chamber(square feet) 800 sf _ 27 Physical depth of the sediment chamber(inches) 49 in 28 Ponding depth in the sediment chamber,above any permanent pool 44 in (inches) 29 Elevation of top of weir between chambers(fmsl) 3069.95 Sand Chamber 30 Volume that can be retained in the sand chamber(cubic feet) 1925 cf 31 Bottom of the sand chamber(fmsl) 3067.95 32 Area of the sand chamber(square feet) 770 sf _ 33 Physical depth of the sand chamber(inches) 68 in 34 Ponding depth in the sand chamber,above the sand surface 30 in (inches) 35 Elevation of the bypass device(fmsl) _ 3072.7 _ 36 Type of bypass device _ WEIR _ 37 Mechanism for distributing flow over the sand surface LEVEL SPREADER 38 Sand specification for sand chamber ASTM C33 _ 39 Depth above underdrain pipe(inches) 18 in _ 40 Will the media be maintained to drain at least two inches per hour at Yes the sand surface? 41 Is at least one clean-out pipe provided at the low point of each Yes underdrain line? 42 Will clean-out pipes be capped? Yes ADDITIONAL INFORMATION 43 Please use this space to provide any additional information about the sand filter(s): Design is a below ground solution.The sediment chamber is composed of 4 precast tanks and the sand chamber of 4 separate precast tanks.All of the sand chambers are below ground(closed bottom). Sand Filter 4 10:39 AM 6/14/2024