HomeMy WebLinkAboutNCG590034_NOD2024PC0105_CEI_Report_20240614DocuSign Envelope ID: C71 F7A73-CA7E-48C4-9DD8-DEB39C5CA906 ROY COOPER co�er�or i ,� ELIZABETH S. B1SER�,°' SecrerQry °virvi v� RICHARD E. ROGERS, JR. NORTH CAROLINA Director Environmental Quality SENT VIA ELECTRONIC MAIL ONL Y.• NO HARD COPY WILL BE MAILED. June 14, 2024 Debra Campbell, City Manager City of Asheville Email: dcampbell@ashevillenc.gov SUBJECT: NOTICE OF DEFICIENCY Tracking Number: NOD-2024-PC-0105 Permit No. NCG590034 Mills River Regional WTP Henderson County Dear Permittee: The North Carolina Division of Water Resources conducted an inspection of the Mills River Regional WTP on May 22, 2024. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NCG590034. A summary of the findings and comments noted during the inspection are provided in the enclosed copy of the inspection report. The Compliance Evaluation inspection was conducted by Division of Water Resources staff from the Asheville Regional Office. The following deficiency(s) was noted during the inspection: Inspection Area Description of Deficiency Flow Measurement - Effluent The flow meter needs to be calibrated annually. ; � Na111Ca1111- rQaalhV l DivW..fWN"P'sources Ashr ilk Rr9ional Office 1 2090 US -Highway 70 1 Swannaraa, North Carallna 28778 62&296.9590 DocuSign Envelope ID: C71 F7A73-CA7E-48C4-9DD8-DEB39C5CA906 Remedial actions should have already been taken to correct this problem and prevent further occurrences in the future. The Division of Water Resources may pursue enforcement action for this and any additional violations of State law. To prevent further action, carefully review these deficiencies and address the causes of non-compliance to prevent the recurrence of similar situations. If you should have any questions, please do not hesitate to contact Rachel Rose with the Water Quality Regional Operations Section in the Asheville Regional Office at 828-296-4500. ATTACHMENTS: Inspection Report Ec: Laserfiche Richard Brock (ORC) Bill Hart (Water Production Manager) Sincerely, Ev DocuSigned by: a,V ACt 66SS E397192DABFB4FF... Daniel Boss, Assistant Regional Supervisor Water Quality Regional Operations Section Asheville Regional Office Division of Water Resources, NCDEQ Asht ll aRtgio Degartc enl 090 U S�Rghw l Qva1 DivisionNorih C-1hp 287 M1she'+ilk Regional Office 120'10 US -Highway 70 I Swannaraa, North Carolina 287I8 62&296.9590 DocuSign Envelope ID: C71 F7A73-CA7E-48C4-9DD8-DEB39C5CA906 United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 u 3 I NCG590034 111 121 24/05/22 I17 18 I C I 19 I s I 20L] 21111I I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I II I I I I I r6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved ------------------- 67 I 72 I n, I 71 I 74 79 I I I I I I I80 701 I 71 I LL -1 I I LJ Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 10:OOAM 24/05/22 21/02/01 Mills River Regional WTP 4037 Haywood Rd Exit Time/Date Permit Expiration Date Mills River NC 28759 12:OOPM 24/05/22 24/07/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Richard Brock/ORC/828-232-4570/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Brendan Kelley,4037 Haywood Rd Mills River NC 28759//828-232-4574/8282324590 Yes Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit 0 Flow Measurement Operations & Maintenar Records/Reports Self -Monitoring Progran 0 Sludge Handling Dispo: Facility Site Review Effluent/Receiving Wate Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date 6/17/2024 C�� Lauren E Armen DWR/ARO WQ/828-296-4500/ pa,��,e»a��°Es Rachel Rose DWR/ARO WQ/828-296-4500/ 6/17/2024 �o Mikal Willmer s°ea°„;°90 DWR/ARO WQ/828-296-4686/ 6/17/2024 oaAaAEaEz°,.e° Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date °y6/17/2024 FVDoculigned Atn tt t bbss EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# DocuSign Envelope ID: C71 F7A73-CA7E-48C4-9DD8-DEB39C5CA906 NPDES yr/mo/day Inspection Type (Cont.) NCG590034 I11 12I 24/05/22 117 18 i c i Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Rachel Rose, Lauren Armeni, and Mikal Wilmer, with the Asheville Regional Office (ARO), met with Roger Brock (ORC & Plant Supervisor, City of Asheville) and Myrriah Ringgenberg (Lab Supervisor, City of Asheville) to conduct a Compliance Evaluation Inspection on May 22, 2024 for the Mills River Regional WTP. This inspection was conducted to determine whether the facility is being operated and maintained in compliance with General NPDES Permit No. NCG590000. This facility was previously permitted through the individual NPDES permit number NC0085511 and was converted to a General NCG59 permit on January 13, 2021. The Mills River Regional WTP is a class 1 conventional water treatment facility with two backwash lagoons. The following item was noted during the inspection: 1. Lagoons: There are two lagoons with one in operation. At the time of the inspection, lagoon #2 was in use and lagoon #1 was offline having the sludge cleaned out of it. The sludge blanket is estimated by sight, but the lagoons are cleaned out annually. The sludge is dried on -site by a portable sludge press and hauled to Upstate Regional MSW Landfill. The following deficiency was noted during the inspection: 1. Flow Measurement - Effluent: The flow meter needs to be calibrated annually. Page# DocuSign Envelope ID: C71 F7A73-CA7E-48C4-9DD8-DEB39C5CA906 Permit: NCG590034 Owner -Facility: Mills River Regional WTP Inspection Date: 05/22/2024 Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ ■ ❑ application? Is the facility as described in the permit? ■ ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ ■ ❑ ❑ Is access to the plant site restricted to the general public? ■ ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? ■ ❑ ❑ ❑ Comment: Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? ■ ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ■ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? ■ ❑ ❑ ❑ Is all required information readily available, complete and current? ■ ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? ■ ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? ■ ❑ ❑ ❑ Is the chain -of -custody complete? ■ ❑ ❑ ❑ Dates, times and location of sampling ■ Name of individual performing the sampling ■ Results of analysis and calibration ■ Dates of analysis ■ Name of person performing analyses ■ Transported COCs ■ Are DMRs complete: do they include all permit parameters? ■ ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ ■ ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified ❑ ❑ ■ ❑ operator on each shift? Is the ORC visitation log available and current? ■ ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? ■ ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility ■ ❑ ❑ ❑ classification? Page# 3 DocuSign Envelope ID: C71 F7A73-CA7E-48C4-9DD8-DEB39C5CA906 Permit: NCG590034 Owner -Facility: Inspection Date: 05/22/2024 Inspection Type: Mills River Regional WTP Compliance Evaluation Record Keeping Yes No NA NE Is a copy of the current NPDES permit available on site? 0 ❑ ❑ ❑ Facility has copy of previous year's Annual Report on file for review? ❑ ❑ 0 ❑ Comment: Lagoons Yes No NA NE Type of lagoons? Facultative # Number of lagoons in operation at time of visit? 1 Are lagoons operated in? Parallel # Is a re -circulation line present? ❑ 0 ❑ ❑ Is lagoon free of excessive floating materials? 0 ❑ ❑ ❑ # Are baffles between ponds or effluent baffles adjustable? ❑ ❑ ■ ❑ Are dike slopes clear of woody vegetation? 0 ❑ ❑ ❑ Are weeds controlled around the edge of the lagoon? 0 ❑ ❑ ❑ Are dikes free of seepage? 0 ❑ ❑ ❑ Are dikes free of erosion? 0 ❑ ❑ ❑ Are dikes free of burrowing animals? 0 ❑ ❑ ❑ # Has the sludge blanket in the lagoon (s) been measured periodically in multiple ❑ 0 ❑ ❑ locations? # If excessive algae is present, has barley straw been used to help control the growth? ❑ ❑ 0 ❑ Is the lagoon surface free of weeds? ■ ❑ ❑ ❑ Is the lagoon free of short circuiting? N ❑ ❑ ❑ Comment: See summary for details. Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? 0 ❑ ❑ ❑ Is flow meter calibrated annually? ❑ 0 ❑ ❑ Is the flow meter operational? EIN ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ 0 ❑ Comment: The flow meter had not been calibrated since December 14, 2021 by CITT Solution Integration. See summary for details. Effluent Sampling Yes No NA NE Is composite sampling flow proportional? ❑ ❑ 0 ❑ Is sample collected below all treatment units? 0 ❑ ❑ ❑ Page# 4 DocuSign Envelope ID: C71 F7A73-CA7E-48C4-9DD8-DEB39C5CA906 Permit: NCG590034 Inspection Date: 05/22/2024 Owner -Facility: Mills River Regional WTP Inspection Type: Compliance Evaluation Effluent Sampling Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type representative)? Comment: The permit requires grab samples. Effluent Pipe Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Comment: The outfall is inundated. Yes No NA NE ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ Yes No NA NE Page# 5