HomeMy WebLinkAboutWQ0031314_Annual Report_20240612 O� ROY COOPER _ n Governor ELIZABETH S.BISER R * a2 Secretary RICHARD E.ROGERS,JR. NORTH CAROLINA Director Environmental Quality June 12, 2024 Delivered electronically via email to: bethb cityofws.org Ms. Courtney Driver— Utilities Director Winston-Salem/Forsyth County Utilities Commission P.O. Box 2511 Winston-Salem, North Carolina 27107 Subject: 2023 Annual Residuals Report Review Swann WTP, Neilson WTP, and Thomas WTP Distribution of Class A Water Treatment Plant Residuals Permit No. WQ0031314 Forsyth County Dear Ms. Driver: On June 7, 2024, Division of Water Resources staff, Kristen Potwora, completed a review of the 2023 Annual Report for WQ0031314. This review reflects compliance with the subject permit. Please refer to the enclosed inspection report for additional comments and observations. If you have any questions, please contact me or Kristen Potwora at the letterhead address and phone number 336-776-9697, or by email at jenny.graznak(a)_deg.nc.gov or kristen.potwora(a)_deg.nc.gov. Sincerely, DocuSigned by: 4. _'!�vteAK 2D3CE3F1B7 OD456_. Jennifer F. Graznak, Assistant Regional Supervisor Water Quality Regional Operations Section Division of Water Resources, NCDEQ-WSRO enc.: Inspection Report cc: Bill Brewer—City of Winston-Salem (Electronic Copy) Brent Collins— EMA(Electronic Copy) Forsyth County Environmental Health (Electronic Copy) DRE�Q5 North Carolina Department of Environmental Quality I Division of Water Resources Winston-Salem Regional Office 1 450 W.Hanes Mill Rd,Suite 300 I Winston-Salem,North Carolina 27105 336.776.9800 Compliance Inspection Report Permit:WQ0031314 Effective: 11/18/20 Expiration: 08/31/27 Owner: Winston-Salem/Forsyth County Utilities Commission SOC: Effective: Expiration: Facility: Winston-Salem/Forsyth County Utilities Commi: County: Forsyth Region: Winston-Salem Contact Person:William C Brewer Title: Phone: 336-727-8000 Directions to Facility: System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On-Site Representative(s): Related Permits: NC0079821 City of Winston-Salem-R.A.Thomas WTP NC0086011 City of Winston-Salem-Neilson WTP Inspection Date: 06/07/2024 Entry Time 11:OOAM Exit Time: 01:OOPM Primary Inspector:Kristen Potwora n Phone: 336-776-9800 Secondary Inspector(s): /12G4yL Pbt(ifJ92C� Reason for Inspection: Routine Inspection Type: Annual Report Review Permit Inspection Type: Distribution of Residual Solids(503 Exempt) Facility Status: Compliant Not Compliant Question Areas: Miscellaneous Questions Record Keeping Treatment Sampling Pathogen and Vector Attraction (See attachment summary) Page 1 of 4 Permit: WQ0031314 Owner-Facility:Winston-Salem/Forsyth County Utilities Commission Inspection Date: 06/07/2024 Inspection Type:Annual Report Review Reason for Visit: Routine Inspection Summary: On June 7, 2024, Division of Water Resources staff, Kristen Potwora, completed a review of the 2023 Annual Report for WQ0031314. This review reflects compliance with the subject permit. Observations: • 313.7 dry tons were land applied in March, April, October, November and December of 2023 in Yadkin and Davie County from the P.W. Swann WTP. • 792.74 dry tons were land applied during June and July of 2023 in Davidson County from the R.W. Neilson WTP. • 475.54 dry tons were hauled to the Hanes Mill Road Landfill in Winston Salem, NC from the R.A. Thomas WTP. 1. The Swann WTP: a) TCLP Analysis was completed for this permit cycle on 12/2/2020. b) Residuals Analysis was sampled on 3/23/23 and 10/2/23. c) Soil Analysis of the fields applied on from the Swann WTP were sampled in November 2023. Results were within parameter limits. Lime was applied on Field#1, Site#DV34. 2. The Neilson WTP: a) TCLP Analysis was completed for this permit cycle on 1/31/2021. b) Residuals Analysis was sampled on 5/15/23 with four samples prior to the June and July land application events. The average of the four samples was used for Annual Metals Field Loading, SAR and PAN calculations. Page 2 of 4 Permit: WQ0031314 Owner-Facility:Winston-Salem/Forsyth County Utilities Commission Inspection Date: 06/07/2024 Inspection Type:Annual Report Review Reason for Visit: Routine Type Yes No NA NE Distribution and Marketing ❑ Land Application Record Keeping Yes No NA NE Is GW monitoring being conducted, if required? ❑ ❑ 0 ❑ Are GW samples from all MWs sampled for all required parameters? ❑ ❑ 0 ❑ Are there any GW quality violations? ❑ ❑ 0 ❑ Is GW-59A certification form completed for facility? ❑ ❑ 0 ❑ Is a copy of current permit on-site? ❑ ❑ ❑ Are current metals and nutrient analysis available? 0 ❑ ❑ ❑ Are nutrient and metal loading calculating most limiting parameters? 0 ❑ ❑ ❑ a. TCLP analysis? 0 ❑ ❑ ❑ b. SSFA(Standard Soil Fertility Analysis)? 0 ❑ ❑ ❑ Are PAN balances being maintained? 0 ❑ ❑ ❑ Are PAN balances within permit limits? 0 ❑ ❑ ❑ Has land application equipment been calibrated? ❑ ❑ ❑ Are there pH records for alkaline stabilization? ❑ ❑ 0 ❑ Are there pH records for the land application site? 0 ❑ ❑ ❑ Are nutrient/crop removal practices in place? ❑ ❑ ❑ Do lab sheets support data reported on Residual Analysis Summary? 0 ❑ ❑ ❑ Are hauling records available? ❑ ❑ 0 ❑ Are hauling records maintained and up-to-date? ❑ ❑ 0 ❑ #Has permittee been free of public complaints in last 12 months? 0 ❑ ❑ ❑ Has application occurred during Seasonal Restriction window? ❑ ❑ ❑ Comment: Pathogen and Vector Attraction Yes No NA NE a. Fecal coliform SM 9221 E(Class A or B) ❑ ❑ ❑ Class A, all test must be<1000 MPN/dry gram Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram Fecal coliform SM 9222 D(Class B only) ❑ ❑ ❑ Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram ❑ b. pH records for alkaline stabilization (Class A) ❑ ❑ ❑ c. pH records for alkaline stabilization (Class B) ❑ ❑ ❑ Temperature corrected ❑ d. Salmonella(Class A, all test must be<3MPN/4 gram day) ❑ ❑ 0 ❑ Page 3 of 4 Permit: WQ0031314 Owner-Facility:Winston-Salem/Forsyth County Utilities Commission Inspection Date: 06/07/2024 Inspection Type:Annual Report Review Reason for Visit: Routine e. Time/Temp on: ❑ ❑ 0 ❑ Digester(MCRT) ❑ Compost ❑ Class A lime stabilization ❑ f. Volatile Solids Calculations ❑ ❑ 0 ❑ g. Bench-top Aerobic/Anaerobic digestion results ❑ ❑ M ❑ Comment: Treatment Yes No NA NE Check all that apply Aerobic Digestion ❑ Anaerobic Digestion ❑ Alkaline Pasteurization (Class A) ❑ Alkaline Stabilization (Class B) ❑ Compost ❑ Drying Beds ❑ Other ❑ Comment: Sampling Yes No NA NE Describe sampling: Is sampling adequate? 0 ❑ ❑ ❑ Is sampling representative? 0 ❑ ❑ ❑ Comment: Page 4 of 4