HomeMy WebLinkAboutNCC241779_Site Plan or Location Map_20240610 NOTES:
I
1. SEE DWG C1 FOR SURVEY AND DATUM
INFORMATION.
O (� ROP9lBR2p021 2. NO
INFORMATION IN OBTAINEDTS ON FROM: FLOODPLAIN
y F NI ' NBN R\OGE
�b z Rp FEMA FIRM MAP:3720171800J
02� a / o EFFECTIVE DATE 5/2/2006
7
�� ♦ sa \\ 3 SITEO STOCKPILE MAY USE MATERIAL MEETING COMMON FROM EXISTING
y, FILL
/ \ REQUIREMENTS AS FILL MATERIAL WHERE SELECT
O FILL IS NOT REQUIRED.
00 I-
MAINTENANCEx w 1 Zm
II1 BUILDING \ C.
•
PROPERTY LINE,TYP. x __
PARCEL AREA:110.48 AC \ N
Ir
L_— SOLIDS /"]ry �I 'I�'
HANDLING �, .
1 oI
SMITH POND ■ p c • u.'L g'!!..``g-
(EXSTORMWATER O ON �="gl
//____
DETENTION) . O , •\
+� FLocc TION AND
OVERFLOW WEIRS MODIFICATIONS ,•rF '�� POWER G SEDIMENTATIONS BASINS
SEE DETAIL 1/DC7 1� BACKWASH r GENERATION
CLARIFIERS ■ • 'FACILITY Z
___—.—_._ - ��.i--- REA 3 MAIN PLANT ENTRANCE
111
/ / FUEL STORAGE .• ILI, _ t__1� •� ...I \
/ (I FACILITY ^7 7( \ . a,a41, '' ��� + ��;
•
/// UV FACILITY I� • rZ _ --
r/ i / / PUMP STATION A 1 ` ��= —r — �'.�--I
_ ` X X—
RECYCLE e'.�f{/�
STORMWATER OUTFALL r 00 F�Ill O�` � �? + X__
/ e • :��605 PUMP STATION(,,(I IIygII II
/ -` AREA 1••F Og��..,._ p "�. 12MG CLEARWELL ��ulu II
�� �:.� III u,u
l r iu uu uu ..
` I 5MG CLEARWELL AREA 2
/ I�
/ LIMITSOF J
DISTURBANCE,x J_ �� D
. TYP \
I
C - '/ /// I EXISTING J o X
` `-� / G/ STOCKPILE 1' t
\\ (SEE NOTE 3) 1 r I I Li
f
y
I (( � ___Q-_ 1 WEST
\\ STORAGETORAGE MAINTENANCE —M. TERMINAL
\\ / \ LAGOON BLDG _ RESERVOIR
U -----1
\)N' ,-..(/
i
\ _\ H
7t '41 \\,... \ .,._._., ,/,..---..--__x_ - .Y, —.-- —.,(••— --X— —7
i/..._.. I
\� --_/
q....''..-- CITY OF RALEIGH-PLANS AUTHORIZED FOR CONSTRUCTION
p -- — i I // / / v-- Y x- --ar_ 1 Plans for the d use have been reviewed for I compliance with applicable codes.This limited review,and t'•�-- -- Y -- — propose genera p pp
O authorization for construction is not to be considered to represent total compliance with all legal requirements for Et
development and construction.The property owner,design Consultants,and contactors are each responsible for H
re _compliance with all applicable City,State and Federal laws.This specific authorization below is not a permit,nor shall it be Z
1 a • -�y _x construed to permit any violation of City,State or Federal Law.All Construction must be in accordance with all Local,State, O
and Federal Rules and Regulations.This approval of this electronic document is only valid if the document has not been U
LIMITS OF DISTURBANCE:6.5 AC I PLAN modified and the dig.'signature below is valid:
E ce
SCALE: 1"= 150' 150 75 0 150' 0
S U SCALE:1"=150' City of Raleigh Development Approval 0
§ PROJECT B.PICKETT CITY OF RALEIGH DATE: AUGUST 2023 ,
m a DESIGNER: HAZENNO.: 32475-003 DESIGNEDBV: C.WILSONi-ia_zei'i
NORTH CAROLINA SITE — OVERALL ZDRAWN BY' A.MARCHCIVIL CONTRACT NO.: 01
DRAWING
CHECKED M.SANTOWASSO E.M. JOHNSON WATER TREATMENT PLANT OVERALL SITE PLAN NUMBER:
a,a HAZEN AND SAWYER
4011 WESTCHASE BOULEVARD,SUITE 500 Ci
<f IF THIS BAR DOES NOT 0 1/2" 1" J
Q F 1 CONFORMED SET 08/2023 JBP MEASURE("THEN DRAWING RALEIGH,NORTH CAROLINA 27607 GENERATOR IMPROVEMENTS—PHASE 2
LL REV ISSUED FOR DATE BY IS NOT TO FULL SCALE Inii= LICENSE NO.:C-0381 C2 I z
2 U-