Loading...
HomeMy WebLinkAboutSW6240504_Supplement-EZ Form_20240607 SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION 1 i Project Name Tri-County Subdivision 2 Project Area(ac) 9.6 --- 3 Coastal Wetland Area(ac) 0 4 Surface Water Area(ac) i 0 5 Is this project High or Low Density? Low 6 Does this project use an off-site SCM? No COMPLIANCE WITH 02H.1003(4) 7 Width of vegetated setbacks provided(feet) 30 8 Will the vegetated setback remain vegetated? ^ Yes 9 If BUA is proposed in the setback,does it meet NCAC 02H.1003(4)(c-d)? N/A 10 Is streambank stabilization proposed on this project? 1 No NUMBER AND TYPE OF SCMs: 11 Infiltration System 12 Bioretention Cell 13 Wet Pond 14 Stormwater Wetland 15 Permeable Pavement 16 Sand Filter 17 Rainwater Harvesting(RWH) 18 Green Roof 19 Level Spreader-Filter Strip(LS-FS) 20 Disconnected Impervious Surface(DIS) 21 Treatment Swale 22 Dry Pond — — --- — — — - _� 23 StormFilter 24 Silva Cell 25 Bayfilter �_-.- 26 Filters FORMS LOADED DESIGNER CERTIFICATION a _ 27 'Name and Title: Kenneth W.Smith Jr.,PE PLS 28 Organization: Smith Site Consultants,PLLC. NC Firm#P-2144 29 Street address: 121 Bulittle Drive 30 City,State,Zip: Linden,NC 28356 31 Phone number(s): 910-391-5923 32 Email: smithsiteconsultants@gmail.com Certification Statement: I certify,under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision;that the information provided in the form is,to the best of my knowledge and belief,true,accurate,and complete;and that the engineering plans, specifications,operation and maintenance agreements and other supporting information are consistent with the information provided here. Designer 01 I 111 -"•• •CC -17 • •••-• "f://,/, f A6. 045277 y� Signature of Designer "'HI'" Seal Date DRAINAGE AREAS 1 Is this a high density project? No •---i 2 If so,number of drainage areas/SCMs 0 f 3 Does this project have low density areas? Yes 1 4 If so,number of low density drainage areas 1 Is all/part of this project subject to previous rule 5 versions? No FORMS LOADED 'DRAINAGE AREA INFORMATION 1 Entire Site LD 1 4 Type of SCM N/A N/A 5 'Total drains a area(sq ft) _ 418180 418180 6 Onsite drains a area(s ft) 418180 418180 7 iOffsite drainage area(sq ft) - 0 0 _8 Total BUA in project(sq ft) _ 100363 sf 100363 sf New BUA on subdivided lots(subject to permitting)' 9 sq ft) 67590 sf 67590 sf New BUA not on subdivided lots(subject to i 10 permiin )(sf) 32773 sf 32773 sf ' 11 Offsite BUA(s ft) none none j 12 Breakdown of new BUA not on subdivided lots: 2 Parking(sq ft) AO -Sidewalk(sq ft) -Roof(sq ft) i -Roadway(sq ft) 32634 sf , 32634 sf j -Future(sq ft) I -Other,please specify in the comment box P below(sq ft)mm 139 sf 139 sf F13New infiltrating permeable pavement on jj subdivided lots(sq ft) N/A N/A n New infiltrating permeable pavement not on 14 subdivided lots(sq ft) N/A N/A Existing BUA that will remain(not subject to 15 permitting)(sq ft) N/A N/A iI 16 Existing_BUA that is already permitted(s ft) N/A N/A _1, 17 j Existing BUA that will be removed(sq ft) N/A N/A , 18 Percent BUA _ 24% 24% 19 Design storm(inches) — 1.0 in 1.0 in 4 20 JDesign volume of SCM(cu ft) N/A N/A 21 !Calculation method for design volume N/A N/A ADDITIONAL INFORMATION Please use this space to provide any additional information about the 22 'drainage area(s): "Other"BUA item is for the concrete access&pad for the new mail kiosk i LOW DENSITY 1DESit5N Ui N 'i-:. LO,Jv DEN31177 { t EL t 3;-,t0m uz:-..1035 1 1 Is project below density thresholds set forth in the applicable stormwater rule? i Yes Bpi 2 Does project maximize dispersed flow and minimize channelization of flow? Yes 1 3 Has the use of piping been minimized per.1003(2)(c)? Yes 4 Side slopes of the vegetated conveyances(H:V) 3 to 1 5 Maximum velocity in the vegetated conveyances during the 10-year storm? 1.29 j 6 Are curb outlet swales proposed? No P 7 Maximum longitudinal slope of curb outlet swale(s)(%) j n/a 8 Bottom width of curb outlet swale(s)(feet) n/a —11 9 Maximum side slope of curb outlet swale(s)(H:V) iT n/a i10 Minimum length of curb outlet swale(s)(feet) n/a -11 11 Are treatment swales used instead of curb outlet swales? Yes 12 Is stormwater released at the edge of the setback as dispersed flow? Yes J 13 Have stormwater outlets been designed to prevent downslope erosion? Yes 14 ,Are variations to rule.1003 proposed? No ADDITIONAL INFORMATION 15 Please use this space to provide any additional information about this low density project: 5 i i A 1 i SEE THE ATTACHED SHEET FOR ALL SWALES INFORMATION p w Drainage Pervious Vactual Flow Swale# Area(ac) BUA(ac) area(ac) C Q(cfs) Slope(%) Vauow(fps) (fps) Depth(ft) 1 0.67 0.19 0.48 0.39 1.47 0.30 5.00 0.79 0.73 2 0.14 0.05 0.09 0.45 0.35 0.30 5.00 0.54 0.43 3 0.06 0.05 0.01 0.71 0.26 0.30 5.00 0.51 0.38 4 0.09 0.02 0.07 0.38 0.18 0.30 5.00 0.47 0.33 5 0.13 0.06 0.07 0.51 0.37 1.25 5.00 0.97 0.33 6 0.10 0.03 0.07 0.43 0.23 1.25 5.00 0.84 0.28 7 0.30 0.08 0.22 0.39 1.47 0.30 5.00 0.79 0.73 8 1.09 0.33 0.76 0.41 2.50 0.30 5.00 0.90 0.89 9 0.36 0.12 0.24 0.44 0.87 0.30 5.00 0.69 0.60 10 1.44 0.38 1.06 0.38 7.95 0.30 5.00 1.21 1.37 11 0.28 0.09 0.19 0.43 2.13 0.30 5.00 0.86 0.84 12 0.47 0.03 0.44 0.25 8.61 0.30 5.00 1.24 1.41 13 0.22 0.05 0.17 0.36 0.44 0.50 5.00 0.71 0.42 14 0.12 0.05 0.07 0.50 0.33 0.50 5.00 0.65 0.38 15 0.12 0.00 0.12 0.20 11.63 0.25 5.00 1.29 1.43