Loading...
HomeMy WebLinkAboutNC0082694_BIMS Report_20240521United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 u 3 I NCO082694 111 121 24/05/03 I17 18 I C I 19 Ls_] 201 I 211111 I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I II I I I I 1166 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved ------------------- 67 1.0 701, I 71 p I 72 I Lr i I 71 I 74 79 I I I I I I I80 LJ J I I Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES Dermit Number) 10:OOAM 24/05/03 15/10/01 Dallas WTP 1342 Dallas -Stanley Hwy Exit Time/Date Permit Expiration Date Dallas NC 28034 12:OOPM 24/05/03 20/07/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted James M Palenick,210 N Holland St Dallas NC 280342749/Interim Town Manager/704-922-3176/7049224701 No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit 0 Operations & Maintenar 0 Self -Monitoring Progran 0 Facility Site Review Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Edward Watson DWR/MRO WQ/ / 5/17/2024 Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date by: FDocuSigned t��•�,t,�W f f Nu t, 5/20/2024 � F-I b-I FtfbyHLU254H3... EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day Inspection Type NCO082694 I11 12I 24/05/03 117 18 i c i Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Page# Permit: NCO082694 Owner -Facility: Dallas WTP Inspection Date: 05/03/2024 Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new 0 ❑ ❑ ❑ application? Is the facility as described in the permit? 0 ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ 0 ❑ ❑ Is access to the plant site restricted to the general public? 0 ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? 0 ❑ ❑ ❑ Comment: The permit expired July 31, 2020. A request for rescission was submitted by the Town of Dallas on 4/13/2022. The Town is requesting the permit be rescinded and replaced with a Certificate of Coverage under general permit NCG59000000. Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? ❑ 0 ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: The Treament lagoon is overtopped capacity. There is water overtopping the berm adjacent tot he walkway across from the drying beds. At the time of the site visit, the drying beds had standing water and sludge in place. By visual observation, it appears the drying beds are not draining fluid and may require maintenance/reconditioning in order to drain properly. There is a storm drain adjacent to the lagoon. With the lagoon currently at holding capacity, there is a significant chance for fluid from the lagoon to travel to the storm drain creating an unpermitted discharge. The conditions were also indentified at this facility during the 2022 inspection. Page# 3