HomeMy WebLinkAboutNC0020389_Compliance Evaluation Inspection_20240607DocuSign Envelope ID: 352lC189-78C7-4A70-B439-5792EADE8D8B ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, JR. Director Kimberly T. Pickett Town of Benson PO Box 69 Benson, NC 27504-0069 NORTH CAROLINA Environmental Quality June 7, 2024 Subject: Compliance Evaluation Inspection Report and Notice of Violation Tracking No. NOV-2024-PC-0347 Benson WWTP NPDES WW Permit No. NCO020389 Johnston County Dear Ms. Pickett: On May 8, 2024, Division of Water Resources (DWR) Raleigh Regional Office (RRO) staff Jesse Barnes conducted a routine compliance evaluation inspection at the Benson Wastewater Treatment Plant (WWTP) in reference to NPDES permit NC0020389. ORC Brian Leavitt was present during the inspection. A review of records, data, treatment components, operations, maintenance, and the outfall area was completed. This review reflected noncompliance with the subject permit. Permit violation(s), item(s) of concern, and other observations are listed below. Inspection findings are detailed in the attached Water Compliance Inspection Report. Permit Violation(s 1. During the inspection, it was unknown if an annual report for the previous year had been created or published. Upon review, an annual report for the WWTP has not been received by DWR and does not appear to be published on the Town of Benson's website. Part II, Section E. (12.) of the subject permit requires permittees who own or operate facilities that primarily collected or treat municipal or domestic wastewater and have an average annual flow greater than 200,000 gallons per day to provide an annual report to DWR and to those served by the permittee. Please refer to Part II, Section E. (12.) of the subject permit for detailed requirements. 2. The certification of the facility's designated backup ORC (BORC), Christopher Brigman, is currently invalid due to overdue annual certification fees and/or insufficient continuing education hours. Part II, Section C. (1.) (b.) of the subject permit requires the designated BORC to possess valid certification. Please direct certification questions to certadmin@deq.nc.gov. s) of Concern 3. The flow splitter valve for diverting influent wastewater to the equalization (EQ) basin is located upstream of the influent bar screen and grit removal systems. EQ basin contents are then piped directly to the aeration basins for treatment, so bar screening and grit removal are bypassed when influent is diverted to EQ during high flows. 4. One of the six total mixers for the aeration basins was temporarily offline during the inspection with maintenance pending. North Carolina Department of Environmental Quality I Division of Water Resources D E Q Raleigh Regional Office 13800 Barrett Drive I Raleigh, North Carolina 27609 NORTH CAROLINA oeWM—A or E"f—untal Quality 919.791.4200 DocuSign Envelope ID: 3521C189-78C7-4A70-B439-5792EADE8D8B 5. One of the five total secondary clarifiers was temporarily offline during the inspection with maintenance pending. 6. One of the five total tertiary filters is offline indefinitely due to malfunction and pending facility upgrades. 7. The EQ basin is not equipped with high level alarms or float controls. EQ freeboard is monitored with staff gauges. 8. Some debris (a few rags) was observed in the receiving stream near the outfall. The amount of debris was not excessive, but does support the need for finer bar screening and screening of EQ basin contents. 9. Meritech Inc has performed compliance toxicity analyses for the subject facility and has been listed as NC certified lab #27 on submitted eDMRs. Meritech Inc's lab certification number has changed and is now #165- please correct this on future eDMRs. 10. Two of the three total screw pumps at the influent pump station were inoperable during the inspection due to malfunction with maintenance pending. 11. The influent screw pump station is not equipped with high-level alarms. Observations The Benson WWTP is located at 766 Hannah Creek Rd in Benson, Johnston County, NC. Version 5.0 of NPDES permit NCO020389 became effective May 1, 2021, and will expire at midnight on April 30, 2026. The permitted facility is a 1.9 MGD wastewater treatment facility discharging treated domestic and industrial wastewater. Treatment consists of the following components: bar screens, grit removal, influent Parshall flume with flow measurement, influent composite sampler, influent screw pumps, three extended aeration/oxidation basins, five secondary clarifiers, tertiary filters, chlorine contact basin, de -chlorination, post aeration, effluent flow measurement, effluent composite sampler, aerated sludge lagoon, two stabilization lagoons (EQ), lagoon effluent return pump station, and standby power generator. The facility is authorized to discharge treated wastewater to Hannah Creek (Stream Index: 27-52-6), designated Class C; NSW waters of the State within sub -basin 03-04-04 of the Neuse River Basin. The facility was as described in the subject permit. The January 2024 discharge monitoring report (DMR) and associated laboratory reports, calibration records, chains of custody, and ORC visitation log were reviewed for completeness, transcription accuracy, and permit compliance. All reviewed records and reports appeared to be complete and compliant during the inspection with no errors found. Please see Items 1 and 2, above. Field parameters and some non -field parameters are performed in house, under lab certification #196. Remaining parameters are performed by Waypoint Analytical - Greenville (#10), and Meritech Inc (#165). See Item 9, above. A cursory review of the in-house laboratory was conducted with no issues found. The temperature of the sample storage refrigerator was 2 OC during the inspection. The temperature of the fecal coliform incubator was 44.5 OC during the inspection. Current NIST certificates were available for all laboratory thermometers. One automatic diesel standby power generator is available on site and can power the entire facility. The generator is tested once monthly under load with the primary power source interrupted. The generator was not tested during the inspection. Mr. Leavitt stated that a maintenance service contract and priority fuel agreement are in place. A coarse manual bar screen is used to screen influent debris. The bar screen is manually raked by operators daily and appeared to be operating properly during the inspection. A grit settling chamber with a mechanical chain and flight scraper system is used to remove additional grit and heavy debris. The grit removal system appeared to be operating properly during the inspection. Screened debris and grit are collected and disposed of via landfill. The influent and effluent ultrasonic flow meters were both last calibrated July 17, 2023, by Clearwater Inc and appeared to be operating properly during the inspection. D E ��� North Carolina Department of Environmental Quality I Division of Water Resources 4Raleigh Regional Office 13800 Barrett Drive I Raleigh, North Carolina 27609 Nprh C AOLINa 919.791.4200 Peparhnanf of Erm.onmaribl Ouali� DocuSign Envelope ID: 3521C189-78C7-4A70-B439-5792EADE8D8B The influent composite sample storage was observed to be 0 °C and the effluent composite sample storage was observed to be 2 °C during the inspection. Both composite samplers collect 120 mL aliquots for every 10,000 gallons of flow and are therefore flow proportional. Sample collection tubing appeared to be clean and in good condition during the inspection- Mr. Leavitt stated that tubing is replaced approximately monthly. A large lagoon is used as an EQ basin and used primarily during high flows. Influent flow can be diverted to the EQ basin as needed by a flow -splitting valve. See Item 3, above. The basin appeared to be operating properly and had adequate freeboard during the inspection. See Item 7, above. The EQ basin appeared to be operating properly during the inspection. A three -channel oxidation ditch/aeration basin system is used for biological treatment. Rotating surface agitators are placed intermittently along two of the three channels for aerobic treatment and one channel has no agitation for anaerobic treatment. The oxidation ditch system appeared to be operating properly during the inspection. See Item 4, above. The facility utilizes the following five circular secondary clarifiers for solids removal: two 12 ft (deep) x 25 ft (diameter), two 15 ft x 25 ft, and one 12 ft x 50 ft (see Item 5, above). Overflow weirs have removable covers for algae control. Sludge depths are monitored manually with a sludge judge and was observed to be 2.5 ft in one of the 12 ft x 25 ft clarifiers on the day of the inspection. The secondary clarifiers appeared to be operating properly during the inspection. Five multimedia gravity downflow tertiary filters are present and four are used for solids removal (see Item 6, above). Each filter consists of a layer of anthracite, sand, and rock. The filters are backwashed approximately 3 to 4 times weekly and backwash wastewater is returned to the facility influent for treatment. The tertiary filters appeared to be operating properly during the inspection. Liquid sodium hypochlorite is fed with manually -adjusted static pumps and carrier water into a baffled contact chamber with treated wastewater for disinfection. Liquid calcium thiosulfate is fed into a subsequent unbaffled contact chamber with submerged diffused aeration for mixing to achieve de -chlorination. The disinfection and de - chlorination feed systems, contact chambers, and containment appeared to be compliant and operating properly during the inspection. The effluent outfall discharges to Hannah Creek at the southeast corner of the facility. At the outfall, multiple stream channels appearing as a wetland area make up the receiving stream. The outfall pipe was mostly submerged during the inspection. Effluent flow was observed during the inspection and appeared to be clear and free from foam. See Item 8, above. A path to the outfall has been properly maintained for access. All instream sampling requirements except hardness are waived due to active participation in the Lower Neuse Basin Association, as stipulated in the subject permit. Instream hardness analyses are performed by Waypoint Analytical — Greenville. Please respond to this notice, in writing via email or letter to this office, within 30 business days of receipt. The response should address each violation (2) listed above by providing details of planned corrective actions along with estimated completion dates for each violation. Failure to make corrective actions to achieve compliance with the subject permit within a reasonable time may result in further enforcement actions. Please be aware that DWR may take enforcement action against any individual who fails to comply with the requirements of all applicable permits, regulations, and/or statutes. Pursuant to NC General Statute (NCGS) 143- 215.6A, a civil penalty of not more than twenty-five thousand dollars ($25,000.00) may be assessed against any person who violates or fails to act in accordance with the terms, conditions, or requirements of any permit, or applicable regulations, issued pursuant to G.S. 143-215.1. D � ��� North Carolina Department of Environmental Quality I Division of Water Resources Raleigh Regional Office 13800 Barrett Drive I Raleigh, North Carolina 27609 NORTH Io, INA oe�arhne�rofEm,maiu�ar� /'"l 919.791.4200 DocuSign Envelope ID: 3521C189-78C7-4A70-B439-5792EADE8D8B If you need assistance, contact Jesse Barnes by phone at (919) 791-4254 or by email at jesse.barnes@deq.nc.gov. Thank you for your time and assistance. Sincerely, ocuSigned by: E�D A, f. �l.ain,tnt,l,2916E6AB32144F... Vanessa E. Manuel, Assistant Regional Supervisor Water Quality Regional Operations Section Raleigh Regional Office Division of Water Resources, NCDEQ Attachments: 1. Water Compliance Inspection Report, NCO020389 Cc: Laserfiche NOR-H O/+RpLINAD LU oapa0-1 of Ewwmamai avari North Carolina Department of Environmental Quality I Division of Water Resources Raleigh Regional Office 13800 Barrett Drive I Raleigh, North Carolina 27609 919.791.4200 DocuSign Envelope ID: 3521C189-78C7-4A70-B439-5792EADE8D8B United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 u 3 I NCO020389 I11 121 24/05/08 I17 18I � I 19 I s I 201 I 211IIIII 111111III II III III1 I I IIIII IIIIIIIII II r6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved ------------------- 67 I 72 I n, I 71 I 74 79 I I I I I I I80 701 I 71 I LL -1 I I LJ Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES Dermit Number) 09:OOAM 24/05/08 21/05/01 Benson WWTP 766 Hannah Creek Rd Exit Time/Date Permit Expiration Date Benson NC 27504 11:00AM 24/05/08 26/04/30 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Kimberly T Pickett,PO Box 69 Benson NC 275040069/Interim Town Manager/919-894-3553/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit 0 Flow Measurement Operations & Maintenar Records/Reports Self -Monitoring Progran 0 Sludge Handling Dispo: Facility Site Review Effluent/Receiving Wate Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Jesse Barnes Docusigned by: DWR/RRO WQ/919-791-4254/ 6/6/2024 E 3194ED... Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date DocuSigned by: 6/6/2024 EPA Form 3560 §EWPWous editions are obsolete. Page# DocuSign Envelope ID: 3521C189-78C7-4A70-B439-5792EADE8D8B NPDES yr/mo/day Inspection Type (Cont.) NCO020389 I11 12I 24/05/08 117 18 i c i Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) On May 8, 2024, Division of Water Resources (DWR) Raleigh Regional Office (RRO) staff Jesse Barnes conducted a routine compliance evaluation inspection at the Benson Wastewater Treatment Plant (WWTP) in reference to NPDES permit NC0020389. ORC Brian Leavitt was present during the inspection. A review of records, data, treatment components, operations, maintenance, and the outfall area was completed. This review reflected noncompliance with the subject permit. Permit violation(s), item(s) of concern, and other observations are listed below. Inspection findings are detailed in the attached Water Compliance Inspection Report. Permit Violation(s) 1. During the inspection, it was unknown if an annual report for the previous year had been created or published. Upon review, an annual report for the WWTP has not been received by DWR and does not appear to be published on the Town of Benson's website. Part II, Section E. (12.) of the subject permit requires permittees who own or operate facilities that primarily collected or treat municipal or domestic wastewater and have an average annual flow greater than 200,000 gallons per day to provide an annual report to DWR and to those served by the permittee. Please refer to Part ll, Section E. (12.) of the subject permit for detailed requirements. 2. The certification of the facility's designated backup ORC (BORC), Christopher Brigman, is currently invalid due to overdue annual certification fees and/or insufficient continuing education hours. Part ll, Section C. (1.) (b.) of the subject permit requires the designated BORC to possess valid certification. Please direct certification questions to certadmin@deq.nc.gov. Item(s) of Concern 3. The flow splitter valve for diverting influent wastewater to the equalization (EQ) basin is located upstream of the influent bar screen and grit removal systems. EQ basin contents are then piped directly to the aeration basins for treatment, so bar screening and grit removal are bypassed when influent is diverted to EQ during high flows. 4. One of the six total mixers for the aeration basins was temporarily offline during the inspection with maintenance pending. 5. One of the five total secondary clarifiers was temporarily offline during the inspection with maintenance pending. 6. One of the five total tertiary filters is offline indefinitely due to malfunction and pending facility upgrades. 7. The EQ basin is not equipped with high level alarms or float controls. EQ freeboard is monitored with staff gauges. 8. Some debris (a few rags) was observed in the receiving stream near the outfall. The amount of debris was not excessive, but does support the need for finer bar screening and screening of EQ basin contents. 9. Meritech Inc has performed compliance toxicity analyses for the subject facility and has been listed as NC certified lab #27 on submitted eDMRs. Meritech Inc's lab certification number has changed and is now #165- please correct this on future eDM Rs. 10. Two of the three total screw pumps at the influent pump station were inoperable during the inspection due to malfunction with maintenance pending. 11. The influent screw pump station is not equipped with high-level alarms. Observations The Benson WWTP is located at 766 Hannah Creek Rd in Benson, Johnston County, NC. Version 5.0 of NPDES permit NC0020389 became effective May 1, 2021, and will expire at midnight on April 30, 2026. The permitted facility is a 1.9 MGD wastewater treatment facility discharging treated domestic and industrial wastewater. Treatment consists of the following components: bar screens, grit removal, influent Parshall flume with flow measurement, influent composite sampler, influent screw pumps, three extended aeration/oxidation basins, five secondary clarifiers, tertiary filters, chlorine contact basin, de -chlorination, post aeration, effluent flow measurement, effluent composite sampler, aerated Page# DocuSign Envelope ID: 3521C189-78C7-4A70-B439-5792EADE8D8B Permit: NCO020389 Owner -Facility: Benson WWTP Inspection Date: 05/08/2024 Inspection Type: Compliance Evaluation sludge lagoon, two stabilization lagoons (EQ), lagoon effluent return pump station, and standby power generator. The facility is authorized to discharge treated wastewater to Hannah Creek (Stream Index: 27-52-6), designated Class C; NSW waters of the State within sub -basin 03-04-04 of the Neuse River Basin. The facility was as described in the subject permit. The January 2024 discharge monitoring report (DMR) and associated laboratory reports, calibration records, chains of custody, and ORC visitation log were reviewed for completeness, transcription accuracy, and permit compliance. All reviewed records and reports appeared to be complete and compliant during the inspection with no errors found. Please see Items 1 and 2, above. Field parameters and some non -field parameters are performed in house, under lab certification #196. Remaining parameters are performed by Waypoint Analytical - Greenville (#10), and Meritech Inc (#165). See Item 9, above. A cursory review of the in-house laboratory was conducted with no issues found. The temperature of the sample storage refrigerator was 2 °C during the inspection. The temperature of the fecal coliform incubator was 44.5 °C during the inspection. Current NIST certificates were available for all laboratory thermometers. One automatic diesel standby power generator is available on site and can power the entire facility. The generator is tested once monthly under load with the primary power source interrupted. The generator was not tested during the inspection. Mr. Leavitt stated that a maintenance service contract and priority fuel agreement are in place. A coarse manual bar screen is used to screen influent debris. The bar screen is manually raked by operators daily and appeared to be operating properly during the inspection. A grit settling chamber with a mechanical chain and flight scraper system is used to remove additional grit and heavy debris. The grit removal system appeared to be operating properly during the inspection. Screened debris and grit are collected and disposed of via landfill. The influent and effluent ultrasonic flow meters were both last calibrated July 17, 2023, by Clearwater Inc and appeared to be operating properly during the inspection. The influent composite sample storage was observed to be 0 °C and the effluent composite sample storage was observed to be 2 °C during the inspection. Both composite samplers collect 120 mL aliquots for every 10,000 gallons of flow and are therefore flow proportional. Sample collection tubing appeared to be clean and in good condition during the inspection- Mr. Leavitt stated that tubing is replaced approximately monthly. A large lagoon is used as an EQ basin and used primarily during high flows. Influent flow can be diverted to the EQ basin as needed by a flow -splitting valve. See Item 3, above. The basin appeared to be operating properly and had adequate freeboard during the inspection. See Item 7, above. The EQ basin appeared to be operating properly during the inspection. A three -channel oxidation ditch/aeration basin system is used for biological treatment. Rotating surface agitators are placed intermittently along two of the three channels for aerobic treatment and one channel has no agitation for anaerobic treatment. The oxidation ditch system appeared to be operating properly during the inspection. See Item 4, above. The facility utilizes the following five circular secondary clarifiers for solids removal: two 12 ft (deep) x 25 ft (diameter), two 15 ft x 25 ft, and one 12 ft x 50 ft (see Item 5, above). Overflow weirs have removable covers for algae control. Sludge depths are monitored manually with a sludge judge and Page# DocuSign Envelope ID: 3521C189-78C7-4A70-B439-5792EADE8D8B Permit: NC0020389 Owner -Facility: Benson WWTP Inspection Date: 05/08/2024 Inspection Type: Compliance Evaluation was observed to be 2.5 ft in one of the 12 ft x 25 ft clarifiers on the day of the inspection. The secondary clarifiers appeared to be operating properly during the inspection. Five multimedia gravity downflow tertiary filters are present and four are used for solids removal (see Item 6, above). Each filter consists of a layer of anthracite, sand, and rock. The filters are backwashed approximately 3 to 4 times weekly and backwash wastewater is returned to the facility influent for treatment. The tertiary filters appeared to be operating properly during the inspection. Liquid sodium hypochlorite is fed with manually -adjusted static pumps and carrier water into a baffled contact chamber with treated wastewater for disinfection. Liquid calcium thiosulfate is fed into a subsequent unbaffled contact chamber with submerged diffused aeration for mixing to achieve de -chlorination. The disinfection and de -chlorination feed systems, contact chambers, and containment appeared to be compliant and operating properly during the inspection. The effluent outfall discharges to Hannah Creek at the southeast corner of the facility. At the outfall, multiple stream channels appearing as a wetland area make up the receiving stream. The outfall pipe was mostly submerged during the inspection. Effluent flow was observed during the inspection and appeared to be clear and free from foam. See Item 8, above. A path to the outfall has been properly maintained for access. All instream sampling requirements except hardness are waived due to active participation in the Lower Neuse Basin Association, as stipulated in the subject permit. Instream hardness analyses are performed by Waypoint Analytical — Greenville. Page# DocuSign Envelope ID: 3521C189-78C7-4A70-B439-5792EADE8D8B Permit: NCO020389 Owner -Facility: Benson WWTP Inspection Date: 05/08/2024 Inspection Type: Compliance Evaluation Permit (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? Comment: Record Keeping Are records kept and maintained as required by the permit? Is all required information readily available, complete and current? Are all records maintained for 3 years (lab. reg. required 5 years)? Are analytical results consistent with data reported on DMRs? Is the chain -of -custody complete? Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? Has the facility submitted its annual compliance report to users and DWQ? (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? Is the ORC visitation log available and current? Is the ORC certified at grade equal to or higher than the facility classification? Is the backup operator certified at one grade less or greater than the facility classification? Is a copy of the current NPDES permit available on site? Facility has copy of previous year's Annual Report on file for review? Yes No NA NE ❑ ❑ ■ ❑ ■ ❑ ❑ ❑ ❑ ■ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE ■ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ■ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ■ ❑ ❑ ■ ❑ ❑ ❑ ❑ ■ ❑ ❑ Comment: Annual report is not available and has not been received by DWR. BORC's certification is currently invalid. Laboratory Yes No NA NE Page# 5 DocuSign Envelope ID: 3521C189-78C7-4A70-B439-5792EADE8D8B Permit: NCO020389 Owner -Facility: Benson WWTP Inspection Date: 05/08/2024 Inspection Type: Compliance Evaluation Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? 0 ❑ ❑ ❑ Are all other parameters(excluding field parameters) performed by a certified lab? 0 ❑ ❑ ❑ # Is the facility using a contract lab? ■ ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 0 ❑ ❑ ❑ degrees Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? 0 ❑ ❑ ❑ Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? ❑ ❑ ❑ Comment: Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Bar Screens Yes No NA NE Type of bar screen a.Manual b.Mechanical ❑ Are the bars adequately screening debris? 0 ❑ ❑ ❑ Is the screen free of excessive debris? 0 ❑ ❑ ❑ Is disposal of screening in compliance? ■ ❑ ❑ ❑ Is the unit in good condition? 0 ❑ ❑ ❑ Comment: Grit Removal Yes No NA NE Type of grit removal a.Manual ❑ b.Mechanical Is the grit free of excessive organic matter? ■ ❑ ❑ ❑ Is the grit free of excessive odor? 0 ❑ ❑ ❑ # Is disposal of grit in compliance? 0 ❑ ❑ ❑ Comment: Page# 6 DocuSign Envelope ID: 3521C189-78C7-4A70-B439-5792EADE8D8B Permit: NCO020389 Owner -Facility: Inspection Date: 05/08/2024 Inspection Type: Benson WWTP Compliance Evaluation Flow Measurement - Influent Yes No NA NE # Is flow meter used for reporting? ❑ 0 ❑ ❑ Is flow meter calibrated annually? 0 ❑ ❑ ❑ Is the flow meter operational? 0 ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ ❑ Comment: Influent Sampling Yes No NA NE # Is composite sampling flow proportional? 0 ❑ ❑ ❑ Is sample collected above side streams? 0 ❑ ❑ ❑ Is proper volume collected? 0 ❑ ❑ ❑ Is the tubing clean? 0 ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 0 ❑ ❑ ❑ degrees Celsius)? Is sampling performed according to the permit? 0 ❑ ❑ ❑ Comment: Pump Station - Influent Yes No NA NE Is the pump wet well free of bypass lines or structures? 0 ❑ ❑ ❑ Is the wet well free of excessive grease? 0 ❑ ❑ ❑ Are all pumps present? 0 ❑ ❑ ❑ Are all pumps operable? ❑ ■ ❑ ❑ Are float controls operable? 0 ❑ ❑ ❑ Is SCADA telemetry available and operational? ❑ 0 ❑ ❑ Is audible and visual alarm available and operational? ❑ 0 ❑ ❑ Comment: Two of three screw pumps were inoperable during the inspection. Influent pump station is not equipped with high-level alarms or SCADA telemetry. Oxidation Ditches Are the aerators operational? Are the aerators free of excessive solids build up? # Is the foam the proper color for the treatment process? Does the foam cover less than 25% of the basin's surface? Is the DO level acceptable? Are settleometer results acceptable (> 30 minutes)? Yes No NA NE ■ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ Page# 7 DocuSign Envelope ID: 3521C189-78C7-4A70-B439-5792EADE8D8B Permit: NCO020389 Owner -Facility: Inspection Date: 05/08/2024 Inspection Type: Benson WWTP Compliance Evaluation Oxidation Ditches Yes No NA NE Is the DO level acceptable?(1.0 to 3.0 mg/1) ❑ ❑ ❑ Are settelometer results acceptable?(400 to 800 ml/I in 30 minutes) ❑ ❑ ❑ Comment: Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? 0 ❑ ❑ ❑ Is the site free of excessive buildup of solids in center well of circular clarifier? ■ ❑ ❑ ❑ Are weirs level? 0 ❑ ❑ ❑ Is the site free of weir blockage? 0 ❑ ❑ ❑ Is the site free of evidence of short-circuiting? 0 ❑ ❑ ❑ Is scum removal adequate? ■ ❑ ❑ ❑ Is the site free of excessive floating sludge? 0 ❑ ❑ ❑ Is the drive unit operational? 0 ❑ ❑ ❑ Is the return rate acceptable (low turbulence)? 0 ❑ ❑ ❑ Is the overflow clear of excessive solids/pin floc? ■ ❑ ❑ ❑ Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth) 0 ❑ ❑ ❑ Comment: Filtration (High Rate Tertiary) Yes No NA NE Type of operation: Down flow Is the filter media present? ❑ ❑ ❑ Is the filter surface free of clogging? ❑ ❑ ❑ Is the filter free of growth? ❑ ❑ ❑ Is the air scour operational? ❑ ❑ ❑ Is the scouring acceptable? ❑ ❑ ❑ Is the clear well free of excessive solids and filter media? ❑ ❑ 0 ❑ Comment: Chemical Feed Yes No NA NE Is containment adequate? 0 ❑ ❑ ❑ Is storage adequate? ■ ❑ ❑ ❑ Are backup pumps available? ❑ ❑ ❑ ■ Is the site free of excessive leaking? 0 ❑ ❑ ❑ Page# 8 DocuSign Envelope ID: 3521C189-78C7-4A70-B439-5792EADE8D8B Permit: NC0020389 Owner -Facility: Benson WWTP Inspection Date: 05/08/2024 Inspection Type: Compliance Evaluation Chemical Feed Yes No NA NE Comment: Disinfection -Liquid Yes No NA NE Is there adequate reserve supply of disinfectant? 0 ❑ ❑ ❑ (Sodium Hypochlorite) Is pump feed system operational? 0 ❑ ❑ ❑ Is bulk storage tank containment area adequate? (free of leaks/open drains) 0 ❑ ❑ ❑ Is the level of chlorine residual acceptable? ❑ ❑ ❑ Is the contact chamber free of growth, or sludge buildup? 0 ❑ ❑ ❑ Is there chlorine residual prior to de -chlorination? ❑ ❑ ❑ Comment: De -Chlorination Yes No NA NE Type of system ? Liquid Is the feed ratio proportional to chlorine amount (1 to 1)? ❑ ❑ ❑ Is storage appropriate for cylinders? ❑ ❑ 0 ❑ # Is de -chlorination substance stored away from chlorine containers? 0 ❑ ❑ ❑ Comment: Are the tablets the proper size and type? ❑ ❑ ■ ❑ Are tablet de -chlorinators operational? ❑ ❑ ■ ❑ Number of tubes in use? Comment: Equalization Basins Yes No NA NE Is the basin aerated? ❑ 0 ❑ ❑ Is the basin free of bypass lines or structures to the natural environment? 0 ❑ ❑ ❑ Is the basin free of excessive grease? 0 ❑ ❑ ❑ Are all pumps present? ■ ❑ ❑ ❑ Are all pumps operable? ❑ ❑ ❑ Are float controls operable? ❑ ❑ 0 ❑ Are audible and visual alarms operable? ❑ ❑ 0 ❑ # Is basin size/volume adequate? ■ ❑ ❑ ❑ Comment: No aeration in EQ. Page# 9 DocuSign Envelope ID: 3521C189-78C7-4A70-B439-5792EADE8D8B Permit: NC0020389 Owner -Facility: Benson WWTP Inspection Date: 05/08/2024 Inspection Type: Compliance Evaluation Standby Power Yes No NA NE Is automatically activated standby power available? 0 ❑ ❑ ❑ Is the generator tested by interrupting primary power source? 0 ❑ ❑ ❑ Is the generator tested under load? 0 ❑ ❑ ❑ Was generator tested & operational during the inspection? ❑ ❑ ❑ Do the generator(s) have adequate capacity to operate the entire wastewater site? 0 ❑ ❑ ❑ Is there an emergency agreement with a fuel vendor for extended run on back-up ■ ❑ ❑ ❑ power? Is the generator fuel level monitored? 0 ❑ ❑ ❑ Comment: Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? 0 ❑ ❑ ❑ Is flow meter calibrated annually? 0 ❑ ❑ ❑ Is the flow meter operational? 0 ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ ❑ Comment: Effluent Sampling Yes No NA NE Is composite sampling flow proportional? 0 ❑ ❑ ❑ Is sample collected below all treatment units? 0 ❑ ❑ ❑ Is proper volume collected? ■ ❑ ❑ ❑ Is the tubing clean? 0 ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 ■ ❑ ❑ ❑ degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type ■ ❑ ❑ ❑ representative)? Comment: Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? 0 ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? ❑ 0 ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ 0 ❑ Comment: A few raps were observed in the receiving stream near the outfall during the inspection. Page# 10 DocuSign Envelope ID: 3521C189-78C7-4A70-B439-5792EADE8D8B Permit: NC0020389 Owner -Facility: Benson WWTP Inspection Date: 05/08/2024 Inspection Type: Compliance Evaluation Upstream / Downstream Sampling Yes No NA NE Is the facility sampling performed as required by the permit (frequency, sampling type, 0 ❑ ❑ ❑ and sampling location)? Comment: Page# 11