Loading...
HomeMy WebLinkAbout20071806 Ver 1_More Info Received_20071210~_ ~~~ ~ 919-418-501 L ubas~ ],~~~Y~ C K O P.O. Box 27052 ENVIRONMENTAL Raleigh, NC 27611-7052 www.MaycockEnvironmental.com December 8, 2007 Mr. Ian McMillan ~~''~~~' 401 Oversight/Express Review Permitting Unit NCDENR/DWQ ~"`~ ~ ~ ZL~07 2321 Crabtree Boulevard, Suite 250 t~ka,:F? _wn~~~~ ~AI,~YY Raleigh, NC 27604 ~t~~ti~~~~°fio"~"`~~ Subject: DWQ Project # 07-1808. Response to Request for More Information letter for East Village of Clayton, UT to Neuse River (030402, 27-(38.5), WS-IV, NSW.) Dear Mr. McMillan: In response to your request for more information on the subject project, we have addressed each item in you letter dated November 9, 2007, and received on November 12. 2007. Initially, we had applied for a Nationwide Permit #29, for Residential Development and the corresponding Water Quality Certification #3631, however it has come to my attention that some commercial, mixed use development is planned for the subject property, so we would like to request authorization at this time also under Nationwide Permit #39, Commercial and Institutional Developments, and the corresponding Water Quality Certification # 3705. Also, the stream crossing shown as impact A was incorrectly shown as a jurisdictional impact, as the stream in question was not determined to be jurisdictional, or subject to Neuse River Riparian buffer rules by DWQ in 2004. However, an additional impact has been identified to a jurisdictional stream channel by a sewer line crossing. This impact is now shown as Stream Impact A, and will need to be authorized under Nationwide Permit # 12, Utility Crossings, and the corresponding Water Quality Certification # 3699. We hope that the attached figures and revised preconstruction notification application will resolve this for your review. Additional Information Requested: 7. Please provide cross section details showing the provisions for aquatic life passage. Response: The original stream crossing in question (Stream Impact A) does not involve impacts to a jurisdictional stream, per DWQ stream call on December 6, 2004, when it was determined to be less than intermittent by Mike Horan. Because it is an ephemeral channel, no aquatic passage provisions are required. 2. Please indicate all stream crossing impacts including all fill slopes, dissipaters and bank stabilization on the site plan. Please show all impact locations on the overall site plan. Response: The stream crossing in question is not jurisdictional and was mistakenly shown on the site plan. We have shown the linear wetland impact by the road crossing and the sewer line crossing impact for your review. Please see the attached figures and revised site plan. 3. Please indicate the diffuse flow provision measures on the site plan following the wet detention ponds and submit diffuse flow provision measure worksheets and a signed and notarized Operations and Maintenance Agreement. Response: All Storm water detention facilities are outside of the riparian buffer zone and therefore the worksheets and Operations and Maintenance Agreement are not required, according to 15A NCAC 2B .0233. Also, it is not feasible to provide a signed and notarized Operations and Maintenance Agreement at this time. 4. Please clarify Figure 5. Storm water facility No. 1 and Storm water facility No. 2 are not adjacent on the overall site plan, but are adjacent on Figure 5. Response: Please see the attached revised Figure 5. 5. Also, please clarify if Figure No. 5 corresponds to Impact A (stream impact). The PCN states 80-foot impact, but Figure 5 states 80-foot pipe, and shows wing walls and a long dissipater pad. Please see our response to Item #1, that the impact was erroneously shown as jurisdictional stream impact, and should be disregarded. 6. Please clarify why there is no road crossing shown on the site plan. Response: Please see the revised site plan. We have attempted to respond to each of your requests for additional information in your letter, and hope that your review can now proceed. You can reach Ms. Maycock at (919) 418-7645 if you have any further questions. Si cerely, ~~~ Robin L. Maycock CC: Ms. Lauren Witherspoon, DWQ Raleigh Regional Office Mr. Thomas Brown, USACE Raleigh Regulatory Field Office Mr. T. Patrick Shillington, PE, Engineering and Environmental Sciences (E2S) Mr. James E. Thiem, III, ASLA, Hager-Smith Design Mr. Shane Hensley, UHF Development