Loading...
HomeMy WebLinkAboutNCC230375_MODIFICATION Supporting Documents_20240531 (3) Copyright 2022 Appian Consulting Engineers, P.A. These drawings have been prepared as instruments of service for a particular site or building improvement and remains the property of the Engineer for use under his supervision. No reproduction or other use is allowed without his permission. M/DY GRAINGER IBLLARD 0610.42 n ' PoGDI GENE CARRELL III PIA'0135.04-60 6762.000 ____ -- / O6 B.PC 70 QD R:01.04-60-0971.000 _9 — / ---—__—__—_"— "_— III � �= �-o4/ eoYN� �/ _" __-------_ " _GANGER TREE ZONE\ / —__— ___---- LOW IMPACT/SELECTIVE CLEARING e 4 P,__— _ '��♦�♦9�•�♦�/Pul I n 1 NORTH \ 011 /- — LOW IMPACT/SELECTVE CLEARING SHALL COMPLY WITH :♦.Q♦4�1 IIII� � ADDITIONAL PERMITTED AREA THE SAME MISSION ROW "HANG CLEARING"IN THE .:.:♦:♦J♦:�, I 111 \/ \ DEP TRANSMISSION ROW CLEARING SPECIFICATIONS. LOW • r IMPACT/SELECTVEFROMMATS CLEARING INVOLVES MACHING ���I�'� _ _____-----"" / CLEARING FROM W,THN 4"OF THE GROUND �•�♦�•Q�••' \ STUMPING ANDRE NOTALL BE NO DISTJRBANCEEOFING.GRADING,THE ROOT MAT. ,�♦�•�•'�♦�♦q (— H 001019 VU�60n \ / .♦♦♦♦♦�O♦♦♦� I III PI:0135.04-60-44T6000 NCKIE SIXES LOV£ii .♦♦♦..�♦♦♦♦ ,,, / DB 1019 PC 160 t sI t-4°rr.6B / PID:0135 04-60-4 426.000 �♦:•�♦:4.. /0 I sfa-456239.69 — \. �:�=�:� I WATTLES, TEMPORARY BRIDGE, PANELS. \ ♦♦♦♦`'♦♦ / WATTLES,MATTING,ETC., _— ♦**o♦ , IIIII PER CT-65382 ----- _ -- ""_ ----- o����'' ' ! IIII r 0, 2"05 __ ��.��� \i I -9a05' — .V / �� � �.,� _ u ditch o - - -daze g . se, • • ill \ry I I Yll II ACCESS SURFACEFTR TO BIE NE USED NFORANCE.ACCESSXISTING PATH(NO GRED DING. "' I NO LAND n OST URBAN S CE PROPOSED.ANYSIU DIRED GRASS TO BE SEEDED • • • 11 • C£ORfF HUB£RT SALES SP. �I DB 690 PG BTP ,, , , , , , , \ R'A OIJSO4-60-I153000 F I , ,,\, , EROSION CONTROL SEGMENT 9 • ). IIII REFER TO CONSTRUCTION SEQUENCE /MITI PREVIOUSLY PERMITTED AREA:4.9 Ac. TORN 609TABBOR arr ADDITIONAL AREA DISTURBED 3.0 Ac. PO.0/3400-SO-9 5000 TOTAL AREA DISTURBED= 7.9 Ac. �`� IIII LC�C�Cf�DD e 1 / I I i 1�,' VARY PER SHEE(OBJECT PEN T REQUIREMENTS)COLOR/THICKNESS/SHADE MAY INSTALL TEMPORARY BRIDGE PANELS, • WATTLES,MATTING,ETC., _ / I II PER CT-65382 _ -- - EX.ADJACENT PROPERTY LINES __ EX.STD.RIGHT-OF-WAY I / I ,� IIIII _ -- AAA - EX.ESMENT LINE t \ / / I'IA w,,,,.�-- __ - �re�----- EX CONTOURS(1'INTERVAL) EDGE EX PAVEMENT - — 86 �""='.297 TABOR INDUSTRIAL PARK ROAD EDGE EX GRAVEL --- .;e 75 PG 29) • �__�__�__i EX WOODS LINE (MB EX BUSH/BRUSH LINE - -- • a_— — _ _— — - •_ _ __ — EX DITCH �♦�♦������� __ -- - __ -- - o = EX STORM DRAINAGE ��♦�.� No LAND III DISTURBANCE , —-_ -- gb gT z4, __ - \`\ — 9, EX.U.G.GROUNDING CABLE � ♦♦♦• (SEE NOTES) S.R. 1377 Lox) i --yy ..PH. _ ---6_ mx-97.T0'�__ -— ——ohe — EX.O.H.POWER ����� e.°/9,ww(nPJs� 6—s- - __._. TA__ INDUSTRIAL PARK bg ,INSTALL Ex GUY vnRE(s) R/W II t'O"BrO""wl 'r EX TRANSFORMER STRUCTURES SO' PUBLICyll __ —, °/9�°t k Ns./ pm — INSTALL TEMPORARY BRIDGE PANELS, —fo—— EX U.G.FIBER OPTIC LINE LOD LOD j - 5 WATTLES,MATTING,ETC., Ya O __ -- 1'69 / / �" PER CT-65382 EX.WALLCONC STRUCTURES 1—o-CSF ❑ • • SF�- ___ -- I • ■SFt� -.-in - _ °r 4 u64 I U IIIII EX.BOLLARD EX.WALL STRUCTURE a —- • m.=4BRTt / / - u9e EX U.G.POWER CONSTRUCTION DOUBLE SILT FENCE __�- I c� I IIIII�II _ FENCE ip• WHERE SHOWN —unk — Ex.UNKNOWNH.POWERU.G.LINE - IIII OHE PRO O.H. / I )III 1 UGE PRO U.C..POWER / ELEV PROPOSED CONTOUR • Po / II I1 1 LOD LIMITS OF DISTURBANCE N H.B.R:0134.0T PEVO613aoo UST I / I` 0 EXISITING POLE EROSION LEGEND _ CT-65376 Wattle DB 0 PG 143 —_ -"— % PROPOSED POLE 36 I / I _------- UG UNDERGROUND •--F• CT-65380 Silt Fence / TEMP • OH OVERHEAD III��II TEMPORARY CT-65395 Construction Entrance ,I I/ / / I lain DO NOT DISTURB ® .f / I.I 1m" TO BE REMOVED HELENA CHEMICAL COMPANY MATCH LINE(SEE SHEET 7B) HELL L.DUMMY REVOCABLE TRUST ® AMC TAX DEPAR1uENr / DB 930 PG 447 IFG 41 PRO.FINISHED GRADE ELEVATION DB 933 PC 576 9 PIA:0/34.09-69-7339.000 CT-65387 Concrete Washout Pit wD:or3aoz-5sa5e1.oaoI MATCH LINE(SEE SHEET 7A) �� USG# PRO.SUBGRADE ELEVATION / / / 9�1 li EX 31 EXISTING ELEVATION 104.06/ Impervious Dike ACCESS FOR LINE MAINTENANCE.EXISTING GRASSED ®FES# i � 1004.07 &Pumparound SURFACE TO BE USED FOR ACCESS PATH(NO GRADING. I I EARTHWORK,STONE,ETC.PROPOSED)NO LAND LOD Limits of Disturbance / DISTURBANCE PROPOSED.ANY DISTURBED GRASS TO BE SEEDED -o—CSF 5 CSF Construction Fence 1 1 i ?III . • :o CONSULTING ENGINEERS, P.A. BOUNDARY DESCRIPTION SHOWNCIVIL, MUNICIPAL& 4., DUKE SCALEEA r=60' STRUCTURAL ENGINEERS IS NOT FOR RECORDATION. o 60 zo so eo 210 zbo ;`AR, Ng''..' 11nininir BLN = C0562 ENERGY® SEAL _ E E (] E 2317 Professional Dr. CONSTRUCTION SAFETY EXISTING CONDRIONS: = 46959 fft,44s/ P.O. Box 7966 PROGRESS The contractor shall be responsible for reviewing all • Rocky Mount, N.C. 27804 These drawings do not contain the requirements for existing job conditions. Any adverse existing conditions 'O''•CyC INEL '�9$ Phone: (252) 972-7703 Job safety. All provisions for safety shall be the sole affecting work shown on these drawings shall be BEFORE YOU DIG, ��'.9k/a s' TABOR CITY 115KV SUBSTATION REBUILD responsibility of the contractor. brought to the attention of the engineer for possible CALL 444 C. gt%% www.appianengineers.com clarification or reconciliation. CAUTION: WARNING: a% dmin®appianenglneers.com 126 SEALS STREET,TABOR CITY,NC 28463 04�6'OZA,1 These plans are for bidding purposes only and 8 EROSION AND SEDIMENTATION CONTROL PLAN LINE MAINTENANCE(NORTH) areAll not to be used as Construction drawings RECORD DRAWINGS: V UNDERGROUND TELEPHONE AND OVERHEAD POWER IN VICINITYA unless initialed and dated as d for These drawings are believed to be a correct A FIBER OPTIC LINES ARE IN A OF WORK AREA. CONTRACTOR approve / COUNTY:COLUMBUS SCALE RATIO 1:1 DEP PROJ NO: 1 708 01 001 Construction below by the Engineer. representation of actual field conditions but / VICINITY OF SUBSTATION.not warranted as such. CONTRACTOR TO VERIFY SHALL USE CAUTION WHILE ©WORKING AROUND ENERGIZED A SCALE: 1" = 60' CHK. David Revoir TASK ED02 Approved for Construction: are NORTH CAROLINA e ONE-CALL CENTER LOCATION PRIOR TO DIGGING. POWER LINES. 04/26/24 REVISED LOD FOR LINE MAINTENANCE KAW DCR DRAWN: Kelly Williams APP - DEP DWG NO: 81084 Date: By: Date: www.ncocc.org NO. DATE REVISION BY CK. APP. DATE: 04/26/24 ACE J.N.: 22-023 SHEET 7B OF 17