Loading...
HomeMy WebLinkAboutSW8970705_HISTORICAL FILE_19990803 STORMWATER DIVISION CODING SHEET POST-CONSTRUCTION PERMITS PERMIT NO. SW8 q l 01 05 DOC TYPE ❑ CURRENT PERMIT ❑ APPROVED PLANS ® HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE �g1)q p�SU3 YYYYMMDD State of North Carolina Department of Environment • and Natural Resources A7 Wilmington Regional Office Illk OM, 111111111k James B. Hunt, Jr., Governor C®ENK Wayne McDevitt, Secretan NORTH eAROUNA DEPARTMENT Or Division of Water Quality ENVIRONMENT AND NATURAL RESOURCE5 August '), 1999 Mr. D. Webster Trask, General Partner T.F. Holdings, Limited Partnership 1202 Eastwood Road Wilmington,NC 28403 Subject: Permit No. SW8 970705 Modification Gourmet Center Subdivision High Density Subdivision Stormwater Project New Hanover County Dear Mr. Trask: The Wilmington Regional Office received a complete modification to the Stormwater Management Permit Application for Gourmet Center Subdivision on May 13, 1999. Staff review of the plans and specifications has determined that the project, as proposed,will comply with the Stormwater Regulations set forth in Title 15A NCAC 2H.1000. We are forwarding Permit No. SW8 970705 Modification, dated August 3, 1999, for the construction of the project, Gourmet Center Subdivision. This permit shall be effective from the date of issuance until August 3, 2009, and shall be subject to the conditions and limitations as specified therein. Please pay special attention to the Operation and Maintenance requirements in this permit. Failure to establish an adequate system for operation and maintenance of the stormwater management system will result in future compliance problems.This modification is being issued to include additional built-upon area from the First Union site. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within thirty (30)days following receipt of this permit. This request must be in the form of a written petition,conforming to Chapter 150B of the North Carolina General Statutes,and filed with the Office of Administrative Hearings,P.O. Drawer 27447,Raleigh,NC 27611-7447. Unless such demands are made this permit shall be final and binding. If you have any questions, or need additional information concerning this matter,please contact Linda Lewis,or me at(910) 395-3900. Sincerely, Rick Shiver - Water Quality Regional Supervisor RSS/:arl S:\WQS\STORMSI'AT\PERMln970705.AUG cc: Mark Har-rove, P.E. Tony Roberts,New Hanover County Inspections Beth Easley,New Hanover County Engineering Linda Lewis Wilmington Regional.Office Central Files 127 Cardinal Dr. Ext.,Wilmington,North Carolina 28405 Telephone 910-395-3900 FAX 910-350-2004 An Equal Opportunity Affirmative Action Employer 50% recycled/10% post-consumer paper State Stormwater Management Systems Permit No. SW8 970705 Modification STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY STATE STORMWATER MANAGEMENT PERMIT HIGH DENSITY DEVELOPMENT In accordance with the provisions of Article 21 of Chapter 143,General Statutes ofNorth Carolina as amended,and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO T.F. Holdings, Limited Partnership Gourmet Center Subdivision New Hanover County FOR THE construction,operation and maintenance of a wet detention pond in compliance with the provisions of 15A NCAC 2H .1000 (hereafter referred to as the "stormwater rules') and the approved stormwater management plans and specifications and other supporting data as attached and on file with and approved by the Division of Water Quality and considered a part of this permit. This permit shall be effective from the date of issuance until August 3, 2009 and shall be subject to the following specified conditions and limitations: I. DESIGN STANDARDS 1. This permit is effective only with respect to the nature and volume of stormwater described in the application and other supporting'data. 2. This stormwater system has been approved for the management of stormwater runoff as described on page 3 of this permit, the Project Data Sheet. The subdivision is permitted for 5 lots, each allowed a maximum of 85% of the lot area as built-upon area. 3. Approved plans and specifications for this project are incorporated by reference and are enforceable parts of the permit. The original August 27, 1997, plans remain in effect, with the exception of the First Union site. The proposed built-upon area has been increased for the First Union, and those revised plans are included with the approved plans. 2 State Stormwater Management Systems Permit No. SW8 970705 Modification DIVISION OF WATER QUALITY PROJECT DATA SHEET Project Name: Gourmet Center Subdivision Permit Number: SW8 970705 Modification Location: New Hanover County Applicant: Mr. D. Webster Trask, General Partner Mailing Address: T.F. Holdings, Limited Partnership 1202 Eastwood Road Wilmington, NC 28403 Application Date: May 13, 1999 Name of Receiving Stream /Index #: Bradley Creek/(CFR 18-87-24-4-1) Classification of Water Body: "SC HQW #" If Class SA, chloride sampling results: n/a Design Storm: V Pond Depth, feet: 4.5 Permanent Pool Elevation, FMSL: 33 Total Impervious Surfaces, ft2: 250,516 5 lots at 85% of the lot area, ft2: 187,587 Roads/Parking, ft2 37 740 Other, ft2 n/a Offsite Area entering Pond, ft2: First Union Site @25,189, per Engineer Required Surface Area, ft2: 19,688 Provided Surface'Area, ft2: 20,443 Required Storage Volume, ft3: 20,283 Provided Storage Volume, ft3: 21,147 Temporary Storage Elevation, FMSL: 33.95 Controlling Orifice: 2"(� pipe 3 State Stormwater Management Systems Permit No. SW8 970705 Modification II. SCHEDULE OF COMPLIANCE 1. No homeowner/lot owner/developer shall fill in, alter,or pipe any drainage feature(such as swales) shown on the approved plans as part of the stormwater management system without submitting a revision to the permit and receiving approval from the Division. 2. The permittee is responsible for verifying that the proposed built-upon area does not exceed the allowable built-upon area. Once the lot transfer is complete,the built-upon area may not be revised without approval from the Division of Water Quality, and responsibility for meeting the built-upon area limit is transferred to the individual property owner. 3. The following items will require a modification to the permit: a. Any revision to the approved plans, regardless of size. b. Project name change. C. Transfer of ownership. d. Redesign or addition to the approved amount of built-upon area. e. Further subdivision of the project area. f. Filling in, altering, or piping of any vegetative conveyance shown on the approved plan. 4. The Director may determine that other revisions to the project should require a modification to the permit. S. The Director may notify the permittee when the permitted site does not meet one or more of the minimum requirements of the permit.Within the time frame specified in the notice,the permittee shall submit a written time schedule to the Director for modifying the site to meet minimum requirements. The permittee shall provide copies of revised plans and certification in writing to the Director that the changes have been made. 6. The stormwater management system shall be constructed in it's entirety, vegetated and operational for its intended use prior to the construction of any built-upon surface except roads. 7. During construction,erosion shall be kept to a minimum and any eroded areas of the system will be repaired immediately. 8. The permittee grants permission to DENR Staff to enter the property for the purposes of inspecting the project for compliance with the conditions of this permit. 9. Upon completion of construction,prior to issuance of a Certificate of Occupancy,and prior to operation of this permitted facility,a certification must be received from an appropriate designer for the system installed certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting documentation. Any deviations-from the approved plans and specifications must be noted on the Certification. 10. Decorative spray fountains will not be allowed in the stormwater management system. 11. If the storm water system was used as an Erosion Control device,it must be restored to design condition prior to operation as a stormwater treatment device, and prior to occupancy of the facility. 12. Prior to transfer of ownership, the pond must be inspected by DWQ personnel, and determined to be in compliance with all permit conditions. Records of maintenance activities will be required. 4 State Stormwater Management Systems Permit No. SW8 970705 Modification 13. The permittee shall at all times provide the operation and maintenance necessary to assure the permitted stormwater system functions at optimum efficiency. The approved Operation and Maintenance Plan must be followed in its entirety and maintenance must occur at the scheduled intervals including, but not limited to: a. Semiannual scheduled inspections (every 6 months). b. Sediment removal. C. Mowing and revegetation of side slopes. d. Immediate repair of eroded areas. e. Maintenance of side slopes in accordance with approved plans and specifications. f. Debris removal and unclogging of outlet structure, orifice device and catch basins and piping. g. Access to the outlet structure must be available at all times. 14. Records of maintenance activities must be kept and made available upon request to authorized personnel of D W Q. The records will indicate the date,activity,name of person performing the work and what actions were taken. 15. Prior to the sale of any lot, deed restrictions must be recorded which limit the built-upon area per lot to the amount as shown on the Project Data Sheet,per Section I, Part 2. The recorded statements must follow the form: a. "The maximum built-upon area(BUA)per lot is 85%of the lot area.The allotted BUA includes any built-upon area constructed within the lot property boundaries, and that portion of the right-of-way between the front lot line and the edge of the pavement. Built upon area includes, but is not limited to, structures,asphalt,concrete, gravel,brick,stone,slate,and coquina, but does not include raised, open wood decking, or the water surface of swimming pools." b. "The covenants pertaining to stormwater regulations may not be changed or deleted without concurrence of the State." C. Alteration of the drainage as shown on the approved plan may not take place without the concurrence of the State." d. "Lots within CAMA's Area of Environmental Concern may be subject to a reduction in their allowable built-upon area due to CAMA regulations." e. "All runoff on each lot must drain into the permitted system. This may be accomplished through providing roof drain gutters which drain to the street, grading the lot to draiti toward the street, or grading perimeter swales and directing them into the pond or street.Lots that naturally drain into the system are not required to provide these measures." 16. A copy of the recorded deed restrictions must be submitted to the Division within 30 days of the date of recording the plat, and prior to selling lots. The recorded copy must bear the signature of the Permittee, the deed book number and page, and stamp/signature of the Register of Deeds. 17. This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. 18. A copy of the approved plans and specifications shall be maintained on file by the Permittee for a minimum of ten years from the date of the completion of construction. 5 State Stormwater Management Systems Permit No. SW8 970705 Modification III. GENERAL CONDITIONS 1. This permit is not transferable. In the event there is a desire for the facilities to change ownership, or there is a name change of the Permittee, a 'Name/Ownership Change Form" must be submitted to the Division of Water Quality accompanied by appropriate documentation from the parties involved, such as a copy of the deed of trust. Other supporting materials, such as a signed Operation and Maintenance plan in the case of engineered systems,will also be required. The project must be in good standing with D WQ.The approval of this request will be considered on its merits and may or may not be approved. 2. Failure to abide by the conditions and limitations contained in this permit may subject the,Permittee to enforcement action by the Division of Water Quality, in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. 3. The issuance of this permit does not preclude the Permittee from complying with any and all statutes,rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. 4. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement stormwater management systems. 5. The permit may be modified, revoked and reissued or terminated for cause. The filing of a request for a permit modification, revocation and reissuance or termination does not stay any permit condition. 6. Permittee grants permission to staff of the DWQ to access the property for the purposes of inspecting the stormwater facilities during normal business hours. Permit issued this the 3rd day of August, 1999. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION Kerr T. Stevens, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number SW8 970705 Modification 6 State Stonnwater Management Systems Permit No. SWS 970705 Modification Gourmet Center Subdivision Page 1 of 2 Stormwater Permit No. SW8 970705 Modification New Hanover County Designer's.Certification 1, as a duly registered in the State of North Carolina, having been authorized to observe (periodically/weekly/full time)the construction of the project, (Project) for (Project Owner)hereby state that,to the best of my abilities,due care and diligence was used in the observation of the project construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications. The checklist of items on page 2 of this form are a part of this Certification. Noted deviations from approved plans and specifications: SEAL Signature Registration Number Date 7 State Stormwater Management SystBms Permit No. SW8 970705 Modification Certification Requirements: Page 2 of 2 1. The drainage area to the system contains approximately the permitted acreage. 2. The drainage area to the system contains no more than the permitted amount of built-upon area. 3. All the built-upon area associated with the project is graded such that the runoff drains to the system. 4. The outlet/bypass structure elevations are per the approved plan. 5. The outlet structure is located per the approved plans. 6. Trash rack is provided on the outlet/bypass structure. 7. All slopes are grassed with permanent vegetation. 8. Vegetated slopes are no steeper than 3:1. 9. The inlets are located per the approved plans and do not cause short-circuiting of the system. 10. The permitted amounts of surface area and/or volume have been provided. 11. Required drawdown devices are correctly sized per the approved plans. 12. All required design depths are provided. 13. All required parts of the system are provided, such as a vegetated shelf, a forebay,and the vegetated filter. 14. The overall dimensions of the system, as shown on the approved plans, are provided. cc: NCDENR-DWQ Regional Office Tony Roberts, New Hanover County Building Inspector 8 Fk RECEIVED DICKSON MAY 13 1999 Engin�eers•NIgnncrs•Survegors L.anastape Arsnileds BY:-- May 12, 1999 Ms. Linda Lewis 0 IQ� N.C. Department of Environment, (�� Health, and Natural Resources Division of Water Quality Section 127 Cardinal Drive Extension Wilmington, NC 28405 Re: Modification to Gourmet Center New Hanover County DWQ Project No. SW8 970705 WK Dickson Project No. 90242.80 Dear Ms. Lewis: WK Dickson & Co., Inc. has been retained by Little & Associates to help with site modifications at the First Union Bank site located at 307 South College Road, Wilmington, N.C. The site was recently modified during the construction of Gourmet Center, see DWQ project number above. The current proposed modifications include adding an additional teller drive-thru and moving the ATM machine to the back of the property and adding some additional parking. The additional impervious area amounts to 1,339 square feet. The previous calculations submitted and approved had a small safety factor to allow for a small amount of additional impervious area if needed. The calculations provided show that the current pond has available capacity to handle the additional flow without having to modify the pond. The previously submitted permit applications used the old form and did not have the wet pond supplement, therefor a revised permit application is provided. Enclosed please find the following items: - original completed storm water application and one copy - $420.00 application fee - two (2) copies of the storm water calculations - two (2) copies of plans: C-1 Demolition Plan, dated 5/5/99 909 Market Street 910.762.4200 Atlanta,CA Hiekorg,NC Wilmington,North Carolina Fax910.762.4201 Asheville.NC Rafrigh,NC 28401 www.wkdickson.com Charlolle,NC Columbia,SC C-2 Site Plan and Miscellaneous Details, dated 5/5/99, revised 5/10/99 All of the runoff from the increase in impervious area will be directed via the existing drop inlet to the existing pond in Gourmet Center. The existing pond does not need to be modified, thus a plan showing the pond was not provided. If you need additional information please feel free to call. Sincerely yours, WK DICKSON & Co., Inc. /44de-,o' 4Y t� Mark N. Hargrove, P.E. Encl: cc: C.W. Reece, Little & Associates T.F. Holdings, Limited Partnership I STORMWATER RECEIVED MAY 13 1999 STORMWATER CALCULATIONS FOR FIRST UNION BANK MODIFICATION AT GOURMET CENTER WILMINGTON,NORTH CAROLINA ENGINEERS WK DICKSON & CO.,INC. 909 MARKET STREET WILMINGTON,N.C. 28401 (910) 762-4200 ot"09009e00o0 0 CA 3 SEAL r s,42 w May 11, 1999 yOlAS °o o°0oso# 0I'v4o °° WK DICKSON Engineering 909 Market Street Land Planning Wilmington,NC 28401 Surveying (910) 762-4200 GOURMET CENTER— FIRST UNION SITE MODIFICATION TO R M �Itl6 fl ®ATE Rj TOTAL SITE AREA = 8.51 ACRES Id�6 TOTAL AREA DRAINING TO POND = 358,600 SF E C E 1 V E = 8.23 ACRES JAN 2 ] 2M D TOTAL PROPOSED IMPERVIOUS SURFACE DWQ AREA DRAINING TO POND: ROAD R/W = 37,740 SF EXISTING FIRST UNION BANK = 25,189 SF R UNDEVELOPED PARCELS (ASSUME 85%) = 187,587 SF ADDITIONAL hVIPERVIOUS AREA ATA TM = 480 SF It = 350,996 SF = 5.76 ACRES X PERCENT IMPERVIOUS DRAINAGE AREA FOR POND: = 250,996 SF/358,600 SF = 70.0 '% (l- REQUIRED STORAGE FOR 1-INCH OF RUNOFF FOR POND: (use SChuelel" Method) = 0.05 + 0.009 (I) = 0.05 + 0.009(69.99) = 0.68 _ (1")(0.68)(1/12)(8.23)(43,560) �Q =20,315 CF (21,147 CF PROVIDED - SEE NEXT PAGE) REQUIRED STORAGE FOR FOREBAY: 20% OF FIRST 1-INCH RUNOFF _ (0.2)(20,315) IL = 4,063 CF (4,055 CF PROVIDED - SEE NEXT PAGE) POND DEPTH SA/DA '% POND SURFACE AREA (MIN.) (FT) (SF) 4.5 5.5 19,723 IF POND DEPTH = 4.5 FT, MINIMUM SURFACE AREA = 19,723 SF USED 90% TSS CHART TO SIZE POND AREA @ ELEVATION 33.00 = 20,443 SF > 19,723 SF Revised 10/4/99 02 PROJECT: GOURYET CENTER - IJEVISED SUBJECT: POND CALCULATIONIS,._ .1013 NO.: 90242.80 PREPARED BY: E/ fy_ DA,rE:10 CHECKED BY: DATE:b 1+191 PAGE NO OF 51a S g1 D S k1 0&a-4�" WK DICKSON Engineering 909 Market Street Land Planning Wilmington,NC 28401 Surveying (910) 762-4200 STAGE -AREA -STORAGE FOR 1-INCH RUNOFF ELEV. AREA STORAGE TOT. STORAGE (FT) (SF) (CF) (CF) NORMAL 33.00 20,443 - POOL 21,147 1"RUNOFF 33.95 24,077 21,147 STAGE -AREA -STORAGE FOR FOREBAY ELEV. AREA STORAGE TOT. STORAGE (FT) (SF) (CF) (CF) FOREBAY INV 30.00 478 - 711 31.00 943 711 1248 32.00 1552 1,958 2097 BERM ELEV 33.00 2642 4,055 Revised 5/4/99 PROJECT: GOURMET CENTER - REVISED SUBJECT: POND CALCULATIONS JOB NO.: 90242.80 PREPARED BY: in#JW DATE: A14I99 CHECKED BY: M jNV DATE: SI1t ff PAGE NO Z OF If WK DICKSON Engineering 909 Market Street Land Planning Wilmington,NC 28401 Surveying (910)762-4200 POND RELEASE TIME FOR CONTROL PIPE: ELEV. EFF. STORAGE VOL. RELEASED OUTFLOW RATE RELEASE TIME (FT) (CF) (CF) (CFS) (HOURS) 33.90 21147 3453 0.100 9.6 33.80 17694 4641 0.094 13.7 33.60 13053 4504 0.081 15.4 33.40 8549 4362 0.066 18.2 33.20 4187 4187 0.047 24.8 33.00 0 TOTAL HOURS 81.7 DAYS 3.4 CONTROL PIPE : 2 INCH USED ORIFICE EQUATION TO DETERMINE OUTFLOW RATE Q = Cd'A'(2 h)^1/2 Revised 5/4/99 PROJECT: GOURMET CENTER- REVISED SUBJECT: POND CALCULATIONS JOB NO.: 90242.80 PREPARED BY: mN1F DATE: S y q CHECKED BY: 01104 DATE: Sht 15 PAGE NO 3 OF 4 ,PEC)E➢ VE D JUN 1 7 1998 WK DICKSON June 16, 1998 Ms. Linda Lewis N.C. Department of Environment, Engineers Health, and Natural Resources Planners Surveyors Division of Water Quality Section 127 Cardinal Drive Extension Wilmington, NC 28405 Re: Engineer's Certification Gourmet Center New Hanover County DWQ Project No. SW8 970705 WK Dickson Project No. W9623.80 Dear Ms. Lewis: Enclosed please find one (1) copy of the Engineer's Certification for the referenced project. Sincerely yours, WK DICKSON & Co., Inc. Mark N. Hargrove, P.E. Encl: cc: T.F. Holdings, Limited Partnership 3177 Wrightsville Avenue Other Offices: Atlanta,CA Hickory,NC Wilmington,North Carolina 28403 Asheville,NC Raleigh,NC 910.762.4200 Charlotte,NC Columbia,SC Fax 910.762.4201 wwwmUckson.com