Loading...
HomeMy WebLinkAboutSW8080807_HISTORICAL FILE_20100115 STORMWATER DIVISION CODING SHEET POST-CONSTRUCTION PERMITS PERMIT NO. SW8 (��0 DOC TYPE ❑ CURRENT PERMIT ❑ APPROVED PLANS Pf HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE mo U �L t 5 YYYYMMDD _ r NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Colleen H. Sullins Dee Freeman Governor Director Secretary January 15, 2010 Mr. Billy Miller, Development Committee Chairman Wrightsboro Baptist Church 2736 Castle Hayne Road Wilmington, NC 28412 Subject: Approved Plan Revision Wrightsboro Baptist Church Stormwater Project No. SW8 080807 New Hanover County Dear Mr. Miller: On January 11, 2010, the Wilmington Regional Office received a plan revision for Stormwater Management Permit Number SW8 080807. The revisions include revising the distribution of BUA: Drainage Area Drainage Area 1 2 PYe 1988,1 rtipervl0us''Anea't ... On-Site Buildings 25,323 0 On-Site Streets 50,743 0 On-Site Parking 20,916 0 On-Site Sidewalks 3,880 0 Other On-Site 0 7,849 Off-Site 0 0 Total 100,862 7,849 On-Site Buildings 0 15,945 On-Site Streets 0 41,637 On-Site Parking 0 19,013 On-Site Sidewalks 0 0 Off-Site 0 0 Total 0 76,595 Total, Per Drainage Area: 3.00,862 84,444 Total, Pre-1988 Impervious Area: 108,711 Total, Overall: 185,306 Wilmington Regional Office 127 Cardinal Drive Extension,Wilmington,North Carolina 28405 �TOne 1. Phone:910-796-72151 FAX:910-350-20041 Customer service:1-877-623-6748 1 V orth CarOttllca Internet:www.ncwatequality,org Naturally J��n u a l An Equal Oppodunity 1 Affirmative Action Employer �/!L` {14"!✓,/ SW8 080807 -January 1'5-2010 It has been determined that a formal permit modification is not required for the proposed changes. We are forwarding you an approved copy of the revised plans for your files. Please replace the old approved plan sheet with the new one. Please be aware that all terms and conditions of the permit issued on September 26, 2008, remain in full force and effect. Please also understand that the approval of this revision to the approved plans for the subject State Stormwater Permit is done on a case-by-case basis. Any other changes to this project must be approved through this Office prior to construction. The issuance of this plan revision does not preclude the permittee from complying with all other applicable statutes, rules, regulations or ordinances which may have jurisdiction over the proposed activity, and obtaining a permit or approval prior to construction. If you have any questions concerning this matter, please do not hesitate to call Georgette Scott or me at (910) 796-7215. Sinc Kelly hnson Environmental Engineer GDS\KPJ: S:\WQS\STORMWATER\PERMIT\080807PR.jan09 cc: Phillip Tripp, PE, Tripp Engineering, PC New Hanover County Building Inspections City of Wilmington Development Services Beth E. Wetherill, New Hanover County Engineering Wilmington Regional Office Central Files Page 2 of 2 Job No. 07072 Date: 01/11/10 0 TRIPP ENGINEERING, P.C. 419 Chestnut Street, Wilmington, NC 28401 Phone: (910) 763-5100 • FAX: (910) 763-5631 Email: trippeng@ec.rr.eom LETTER OF TRANSMITTAL To: NCDENR Attention: Kelly Johnsonl Subject: Wrightsboro Baptist Church (SW8 080807) FAX TRANSMITTAL: NUMBER OF PAGES INCLUDES COVER I am sending you: ( X ) ATTACHED ( ) UNDER SEPARATE COVER ( X ) Prints ( ) Tracings ( ) Copy of letter ( ) Specifications ( ) Other Copies Item No. Description 2 CO Cl C3 Site Plans y IAN 1 1 7010 These are transmitted as checked below: ( ) For Approval ( X ) For Your Use ( ) Sign & Return ( ) Review Remarks: In response to Your January 4 2010 email to Phil Tripp we are providing updated plans for your review, The impervious area has been revised in the site data table Please contact us if you have any questions or comments. Thank you. cc: Signed: Larry Knoerl Johnson, Kelly From: Johnson, Kelly Sent: Friday, January 08, 2010 9:55 AM To: 'Larry Knoerl' Subject: RE: Wrightsboro Baptist Church / SW8 080807 Attachments: 080807.pdf OK, thanks. Please send two copies of the plans with the revised data. The draft of the letter is attached. KJ From: Larry Knoerl [mailto:Larry-trippeng@ec.rr.com] Sent: Thursday, January 07, 2010 10:50 AM To: Johnson, Kelly Cc: Phillip Tripp Subject: Wrightsboro Baptist Church / SW8 080807 Kelly: I have reviewed the SW application that was previously submitted for this project and compared it against the plans that were submitted on 9/26/08 and 12/29/09. I also reviewed the spreadsheet that you provided in your email message. Here is a quick summary of what I found: 1) all of the values in the SW application are 100% accurate 2) SW8 080807 is accurate 3) the values on both sets of plans (from Site Data Table) were not 100% accurate. I can only imagine that these values were not properly updated as the design evolved. I have attached a PDF file of the updated Site Data Table which now corresponds with the SW application. In regards to your spread sheet that you provided in your email, the last two columns (G & H) should be identical to the second and third columns of data (B &C). If you agree with my findings, I would be happy to provide you with updated sets of plans which will show the revised Site Data Table. How many would you like to receive? LARRY KNOERL Tripp Engineering, P.C. Office: (910)-763-5100 Fax: (910)-763-5631 NOTICE: This electronic correspondence and all attachments may contain privileged information intended only for the use of the addressee. Any information contained within this correspondence is provided for your convenience. No assertion of accuracy is made by Tripp Engineering, P.C. unless physical documents are obtained, sealed AND signed. User assumes all responsibility for use of this digital information. ro Original Message_ m_.Phil Tngp F _­ To: . To: Larry Kneed Sent: Monday, January 04, 2010 1:40 PM 1 Subject: Fw: Wrightsboro Baptist Church / SW8 080807 Larry, Can you clarify this for Kelly? Phil -----Original Message ----- From: Johnson, Kelly To: Phil Tripp Sent: Monday, January 04, 2010 1:31 PM Subject: Wrightsboro Baptist Church / SW8 080807 Phillip, We received this plan revision request, and I have a question for you regarding the breakdown of the BUA between the two drainage areas. The application on file for the 9/26/08 permit shows that DA#1 has 100,862sf BUA of pre-1988 BUA and DA#2 has 84,444sf of BUA (of which 7,849sf is pre-1988). The permit is written for 84,444sf of BUA. The approved plans from 9/26/08 also show BUA, but it shows a total and not a breakdown. The approved plans show 100,484sf of pre-1988 BUA (which does not match the numbers above.) The plans submitted on 12/29/09 also show 100,484sf of BUA. It is unclear how 100,484sf is dispersed over the two drainage areas? Also, the permitted plans show 158,066sf of BUA, and the 12/29/09 plans show 157,640sf of BUA. Did you intend to reserve 426sf of BUA as future BUA? Please let me know how 100,484sf is determined and also how you want to permit the 426sf. I have summarized this in the attached Excel and PDF files, and will need the data shown in columns G & H to process this revision request. Thanks, Kelly *** My email has changed to kellv.p.iohnsonCdncdenr.¢ov V_IeLL'j i0� VULOVL, Kelly Johnson Environmental Engineer Division of Water Quality Stormwater Permitting 127 Cardinal Drive Extension Wilmington, NC 28405-3845 Office: 910.796.7345 Fax: 910.350.2004 E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. 2 Johnson, Kelly From: Larry Knoerl [Larry-trippeng@ec.rr.com] Sent: Thursday, January 07, 2010 10:50 AM To: Johnson, Kelly Cc: Phillip Tripp Subject: Wrightsboro Baptist Church/SW8 080807 Attachments: 07072-SITE DATA TBL.pdf Kelly: I have reviewed the SW application that was previously submitted for this project and compared it against the plans that were submitted on 9/26/08 and 12/29/09. I also reviewed the spreadsheet that you provided in your email message. Here is a quick summary of what I found: 1) all of the values in the SW application are 100% accurate 2) SW8 080807 is accurate 3) the values on both sets of plans (from Site Data Table) were not 100% accurate. I can only imagine that these values were not properly updated as the design evolved. I have attached a PDF file of the updated Site Data Table which now corresponds with the SW application. In regards to your spread sheet that you provided in your email, the last two columns (G & H) should be identical to the second and third columns of data (B &Q. If you agree with my findings, I would be happy to provide you with updated sets of plans which will show the revised Site Data Table. How many would you like to receive? LARRY KNOERL Tripp Engineering, P.C. Office: (910)-763-5100 Fax: (910)-763-5631 NOTICE: This electronic correspondence and all attachments may contain privileged information intended only for the use of the addressee. Any information contained within this correspondence is provided for your convenience. No assertion of accuracy is made by Tripp Engineering, P.C. unless physical documents are obtained, sealed AND signed. User assumes all responsibility for use of this digital information. ----- Original Message,--.---, ;From: Phil Tripp ..- -.. ------- -- ,-_ _ To: Larry Knoerl Sent: Monday, January 04, 2010 1:40 PM Subject: Fw: Wrightsboro Baptist Church / SW8 080807 Larry, Can you clarify this for Kelly? Phil ----- Original Message .__-_-__ To: Phil Tripp 1 Sent: Monday, January 04, 2010 1:31 PM Subject: Wrightsboro Baptist Church / SW8 080807 Phillip, We received this plan revision request, and I have a question for you regarding the breakdown of the BUA between the two drainage areas. The application on file for the 9/26/08 permit shows that DA#1 has 100,862sf BUA of pre-1988 BUA and DA#2 has 84,444sf of BUA (of which 7,849sf is pre-1988). The permit is written for 84,444sf of BUA. The approved plans from 9/26/08 also show BUA, but it shows a total and not a breakdown. The approved plans show 100,484sf of pre-1988 BUA (which does not match the numbers above.) The plans submitted on 12/29/09 also show 100,484sf of BUA. It is unclear how 100,484sf is dispersed over the two drainage areas? Also, the permitted plans show 158,066sf of BUA, and the 12/29/09 plans show 157,640sf of BUA. Did you intend to reserve 426sf of BUA as future BUA? Please let me know how 100,484sf is determined and also how you want to permit the 426sf. I have summarized this in the attached Excel and PDF files, and will need the data shown in columns G & H to process this revision request. Thanks, Kelly *** My email has changed to kellv.p.iohnsonC@ncdenr.gov KeU,Wohwsow Kelly Johnson Environmental Engineer Division of Water Quality Stormwater Permitting 127 Cardinal Drive Extension Wilmington, NC 28405-3845 Office: 910.796.7345 Fax: 910.350.2004 E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. 2 SITE DATA: OWNER: WRIGHTSBORO BAPTIST CHURCH SITE ADDRESS: 652 CASTLE HAYNE RD. N.H.Co. PARCEL No. R03311-002-003-000 TOTAL AREA 28.08 ACRES DISTURBED AREA 6.34 ACRES ZONING R-20 RESIDENTIAL DISTRICT No. OF BUILDINGS 11 BUILDING ONE 15,945 SF PROPOSED BUILDING AREA 15,945 SF BUILDING COVERAGE 1% SETBACKS (REQUIRED)— FRONT 30' REAR 25' SIDE 15' SETBACKS (PROPOSED)— FRONT 312' REAR 2,100' SIDES 180'/172' PARKING SPACES REQUIRED: 1 SPACE PER 4 SEATS 900 f 4 225 PARKING SPACES REQUIRED: 225 PARKING SPACES PROPOSED: 234 EXISTING IMPERVIOUS AREA 108,711 S,- PROPOSED BUILDING AREA 15,945 SF PROPOSED PAVED AREA 41 ,637 SF PROPOSED GRASS PARKING 19,013 S= TOTAL IMPERVIOUS AREA 85,306 (15.14%) LANDSCAPING AREA REQUIRED: (41 ,637*8%) 3,299 SF LANDSCAPING AREA PROVIDED: 5,935 Sir CAMA LAND USE CLASSIFICATION TRANSITION TREES REQUIRED (15x5.85ACRES) 88 Johnson, Kelly From: Johnson, Kelly Sent: Monday, January 04, 2010 1:32 PM To: 'Phil Tripp' Subject: Wrightsboro Baptist Church / SW8 080807 Attachments: Wrightsboro Baptist.pdf; Wrightsboro Baptist.xlsx Phillip, We received this plan revision request, and I have a question for you regarding the breakdown of the BUA between the two drainage areas. The application on file for the 9/26/08 permit shows that DA41 has 100,862sf BUA of pre-1988 BUA and DAN2 has 84,444sf of BUA(of which 7,849sf is pre-1988). The permit is written for 84,444sf of BUA. The approved plans from 9/26/08 also show BUA, but it shows a total and not a breakdown. The approved plans show 100,484sf of pre-1988 BUA (which does not match the numbers above.) The plans submitted on 12/29/09 also show 100,484sf of BUA. It is unclear how 100,484sf is dispersed over the two drainage areas? Also, the permitted plans show 158,066sf of BUA, and the 12/29/09 plans show 157,640sf of BUA. Did you intend to reserve 426sf of BUA as future BUA? Please let me know how 100,484sf is determined and also how you want to permit the 426sf. I have summarized this in the attached Excel and PDF files, and will need the data shown in columns G & H to process this revision request. Thanks, Kelly *** My email has changed to kelly.p.6ohnson@ncdenr.go 1-e,eLLW0klK6ow Kelly Johnson Environmental Engineer Division of Water Quality Stormwater Permitting 127 Cardinal Drive Extension Wilmington, NC 28405-3845 Office: 910.796.7345 Fax: 910.350.2004 E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. 1 Wrightsboro Baptist Church SW8 080807 Application Plans Permit Plans Plan Revision (9/; 1 (9/26/O8) ":(9/26/08) (12/29/09) (Date TBD) Drainage Area 1 IDrainageArea2 DA#1+DA#2 DA#1+DA#2 I DA#1+DA#2 IDrainageAreal IDrainageAreaZ Pre-1988 Impervious Area On-Site Buildings 25,323 0 Need Need On-Site Streets 50,743 '0 Need Need On-Site Parking 20,916 0 Need Need On-Site Sidewalks 3,880 0 Need Need Other On-Site 0 7,849 Need Need Off-Site 0 0 Need Need Total 100,862 7,849 100,484 100,484 Need Need Mer .. .. m.. .. ... . ,.. ._. ..,,. On-Site Buildings - 0 15,945 15,945 15,945 Need Need On-Site Streets - 0. - 41,637 0 0 Need Need On-Site Parking 0 19,013 0 0 Need Need On-Site Sidewalks 0 0 0 0 Need " Need Other On-Site/"Asphalt"on Plans 0 = 0 41,637 38,441 Need - Need Other On-Site/"Concrete"on Plans 0 0 ': - 0 2,770 Need Need Other On-Site/"Future" 0 0 0 0 Need Need Off-Site 0 0 0 0 Need Need Total 0 76,595 57,582 57,156 Need Need Total: 100,862 84,444 158,066 84,444 157,640 Need Need TRop ENGINEERING, P.C. 0 419 Chestnut Street Wilmington, North Carolina 28401 Phone: (910) 763-5100 FAX: (910) 763-5631 December 29, 2009 REUD p C Q �QR� NCDENR 1. [T U Division of Water Quality 127 Cardinal Drive Wilmington, NC 28405-3845 Attn: Chris Baker Re: Wrightsboro Baptist Church Permit No. SW8 080807 'rE 07072 Dear Mr. Baker: We are requesting a plan revision for the above referenced project. A portion of the roadway has been eliminated, and several sections of sidewalk have been added to the plan. These revisions create no change to the total impervious area or to the limits of disturbance. Please review the enclosed plans and contact us if you have any questions, comments or if you need additional information. Thank you. Sincerely, Tri p Engineering, P.C. Phillip G. Tripp, . .. PGT:dcb Enc. DEC 2 9 2009 BY: I P. 01 t TRANSACTION REPORT SEP-29-2008 MON 12:07 PM FOR: NCDENR 910 350 2004 SEND DATE START RECEIVER TX TIME PAGES TYPE NOTE M# DP SEP-29 12:01 PM 97638046 5' 44" 8 FAX TX OK 290 TOTAL 5M 44S PAGES: 8 State of North Carolina Department of Fuvironmen mnd Nat Off ur l Resources Wilmington Reg William G. Ross,Jr.,Secretary Michael F. Easley, Governor FAX COVER SHEFT c No. Pages(excl,cover): ag .0 p Express Permitting Date: From: Sand�m E To: `� � Phone q 796-7265 co, Fax: 9l0 350-2004 Far: r t�PPortunity ACfirmativc Action Emp nYtr 127 C'.tudinal Drivc Cxtension, Wilmington,NC.R405•(910)79(r7?15•An P.9�1 P. 01 It TRANSACTION REPORT SEP-29-2008 MON 12:00 PM K FOR: NCDENR 910 350 2004 � >K SEND DATE START RECEIVER TX TIME PAGES TYPE NOTE M# DP SEP-29 11 :59 AM 97635631 1'24" 8 FAX TX OK 289 TOTAL 1M 24S PAGES: 8 It State of North Carolina Department of Environment and Natural Resources Wilmington Regional Office Michael F. Easley, Governor William G. Russ, Jr.,Secretary FAX COVER SHEET Date: �- oZ`1t-d No. Pages(excl. cover): Express Permitting To: o>; From: Sandra Exum Co: Phone: (910) 796-7265 Fax: `� l��� 3� I Fax: (910)350-2004. Re: Hard copy to follow 127 Cardinal Drive Extension.Wilmington,NC 28405•(910)796-7215•An Equal Opportunity Atfirmative Action Employer