HomeMy WebLinkAboutNCG550079_Email_20240530 A ASG Engineering 4140 Clemmons Road, Suite 102, Clemmons, NC 27012 tel: 336-778-1111 fax: 336-499-3310 email: auff@asgeng.com web site: www.asgeng.com June 3, 2009 Rose Pruitt NCDENR-DWQ Winston-Salem Regional Office Division of Water Quality, Surface Water Protection .585 Waughtown Street Winston-Salem,NC 27107 Sent pdf via email to Rose.Pruitt@ncmail.net Re: NPDES General Permit NCG550000, Certificate of Coverage NCG550079, Forsyth County, Richard Townsend, 1239 Pine Knolls Rd, Kernersville,Expires July 31,2012 Dear Ms. Pruitt: Rick Townsend and his contractor, Jerry Sprinkle, neglected to inform you within 48 hours of beginning operation of the sand filter constructed per Authorization to Construct NCG550079. I am therefore notifying you of the switchover from the failed nitrification system occurred on or about May 29, 2009. I made three inspections during the construction, The contractor and I have several digital photos of the installation, and we are currently working out a "punch list". I would like to coordinate my final inspection with you at your convenience. The construction was in general accordance with the plans and specifications except for two areas: 1. Mr. Sprinkle elected to have the filter sand delivered in 12 cubic yard ten-wheel dump trucks instead of the 20 cubic yard 18-wheeled dump trailers that I had envisioned. Since 40,CY was required for the job, this was to be done in three full loads plus a portion of a fourth load. Since the filter surface were designed 15% oversize, when I was notified of the partial load I althoxize4-a reduction iz !e filter lentth to --'psi a e it v e ons _ acted filter areas are still via � Min the &esi,.a _y . � �` f ' go 1 9,0W"0.sccton 1a cal,, , 2. Mr. Sprinkle ordered the wrong sand for the job, and the error was not found until it was installed. This is his second installation since the noted ATC criteria, both using this same sand, distributed locally by Pope Sand and Gravel in Winston-Salem, and manufactured by B. V. Hedrick Gravel and Sand Company, Lilesville,NC as "Premium Bunker Sand". Jerry's first installation was completed in February, 2005 and is located at 908 Cedar Branch Trail, Winston-Salem (Forsyth County), the construction was inspected by the Forsyth County Health Department, and the issue with the sand was apparently never found. PRACTICAL CIVIL ENGINEERING SERVICES IN NORTH CAROLINA AND VIRGINIA: COMMERCIAL&RESIDENTIAL SITE DEVELOPMENT FOUNDATIONS-GRADING-DRAINAGE-STRUCTURAL-HYDROLOGY-CULVERTS-PONDS-TRANSPORTATION Rose Pruitt Page 2 of 2 4. The sand meets all of the ATC criteria except for effective size, being about 1/2 smaller. I have discussed this issue at length with Julie Grzyb to obtain policy guidance, and my understanding is that if I, as the engineer of record, approve the installation,then the State will accept it. In order to justify this decision I have obtained effluent samples of the Cedar Branch Trail system and had them analyzed. These results and comparison of related standards are as follows: Parameter Results TS-I Standard TS-II Standard BOD5 8.95 mg/1 <15 mg/1 <10 mg/1 TSS 4.2 mg/1 <15 mg/1 <10 mg/1 Fecal Coliform <1 / 100 ml <10,000/ 100 ml <10,000/ 100 ml Since the sand is smaller in size the surface area of the particles is larger, so in theory the treatment ability of the filters should be enhanced. These test results support this theory. My remaining concern is the potential for clogging, which of course correlates with the expected life of the system. To address this issue I will be increasing my recommendations of septic tank cleaning from 3 years to 2 years. At this point the issue becomes one of a contractual nature between my client,Mr. Townsend, and his contractor,Mr. Sprinkle. Please review your schedule and let me know when can inspect the system. \\� C IApry////�,,i Sincerely, .�� 4Y‘ R p ASG ENGINEERING Q •aV'SS/p' _;QQ y • q SEAL _ N: '2190 ct- Stephen Auffinger,P.E. '';.'ciwe President fYi,y�N AUF�\�`���` i,Irtll!Ir71!11111110`\ cc: Richard Townsend /V-c-W � + r3 i'at r , p,�ea1, Z. Julie Grzyb FL _a of ,,✓vyca.r ,�. 13 errfr / r Jam. JJ C RE: Townsend Plans Page 1 of 2 I. , ,- RE: Townsend Plans Steve Auffinger [auff@triad.rr.com] Sent: Thursday,May 21,2009 10:09 AM To: Julie Grzyb [Julie.Grzyb@ncmail.net] Attachments: Sand Gradation curves.xls(53 KB) Julie, Re: Townsend Property, COC NCG550079 Regarding our conversation yesterday afternoon, the sand that does not meet specification, it is a "Premium Bunker Sand" . I've attached a spreadsheet with chart of their last 5 gradations. The installer, Jerry Sprinkle, claims that he installed-a lined single pass filter with this same sand in February 2005 at 908 Cedar Branch Trail, Winston-Salem. The installation was inspected by the Forsyth County Health Department. You might want to check the records and monitoring of this. installation to see if it is working properly. We appreciate your quick response on this issue. Steve Auffinger ASG Engineering 336-778-1111 Original Message From: Julie Grzyb [mailto:Julie.Grzyb@ncmail.net] Sent: Monday, March 23, 2009 6:21 PM To: Steve Auffinger Subject: Re: Townsend Plans This is fine. I will specify that a representative sample be taken after chlorination/dechlorination in the ATC. Julie Steve Auffinger wrote: > Julie, > I just figured they'd use the outlet above the aeration pad to sample. > Although the dechlorination is chemically instantaneous, the mixing action > of the long corrugated pipe will provide a more representative sample for > regulatory purposes. I've used additional sampling ports after the two sand > filters for trouble shooting. > Let me know if this is OK or if I need to send you a letter. > Steve Auffinger Original Message > From: Julie Grzyb [mailto:Julie.Grzyb@ncmail.net] > Sent: Monday, March 23, 2009 11:12 AM > To: Steve Auffinger https://mail.nc.gov/owa/?ae=Item&t=IPM.Note&i d=RgAAAADL%2fiui1PMHLaQgWkua... 5/21/2009 RE: Townsend Plans Page 2 of 2 > Subject: Townsend Plans k > > Steve, > I received the revised plans on Friday, 3/20/09. Everything looks > fine except for the sampling point. The effluent must be sampled after > chlorination and dechlorination. If you can just send a letter > specifying where the sampling point will be moved in order to meet this > requirement I will write it in on the plans and cite the letter. Sorry, > I did not notice it until today. > Sincerely, > Julie Grzyb Julie Grzyb Environmental Engineer NPDES West/ DWQ N.C. Dept. of Environment and Natural Resources 1617 Mail Service Center, Raleigh, NC 27699-1617 (919) 807-6389; fax (919) 807-6495 E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. https://mail.nc.gov/owa/?ae=Item&t=IPM.Note&id=RgAAAADL%2frmPMHLaQgWkua... 5/21/2009