HomeMy WebLinkAboutWQ0039197_Modification Application (FTSE)_20240529 NC Dept of Environmental Quality
May 29 2024 State of North Carolina
DWRRaleigh Regional Office Department of Environmental Quality
Division of Water Resources
FAST TRACK SEWER SYSTEM EXTENSION APPLICATION
Division of Water Resources FTA 10-23&SUPPORTING DOCUMENTATION
Application Number: W00039197 MOD (to be completed by DwR)
All items must be completed or the auulication will be returned
I. APPLICANT INFORMATION:
1. Applicant's name: Town of Fuquay-Varina(company,municipality,HOA,utility,etc.)
2. Applicant type: ❑Individual ❑ Corporation ❑ General Partnership ❑Privately-Owned Public Utility
❑Federal ❑ State/County ®Municipal ❑ Other
3. Signature authority's name:Michael Wagner per 15A NCAC 02T.0106(b)
Title: Public Utilities
4. Applicant's mailing address: 134 N Main Street
City:Fuquay-Varina State:NC Zip:27526-
5. Applicant's contact information:
Phone number: (919)567-3911 Email Address:mwagner9fuquay-varina.org
11. PROJECT INFORMATION:
1. Project name:Avery Crossing
2. Application/Project status: ❑Proposed(New Permit) ®Existing Permit/Project ❑ARPA funded
If a modification,provide the existing permit number:WQ0039197 and issued date: 05/08/2017,
For modifications,also attach a detailed narrative description as described in Item G of the checklist.
If new construction,but part of a master plan,provide the existing permit number:WQ00
3. County where project is located:Wake
4. Approximate Coordinates(Decimal Degrees): Latitude: 35.5812' Longitude: -78.8277'
5. Parcel ID(if applicable): (or Parcel ID to closest downstream sewer)
111. CONSULTANT INFORMATION:
1. Professional Engineer:Jay T Meyers License Number: 19970
Firm:Meyers Engineering,PLLC
Mailing address: 5708 Carriage Park Court
City:Fuquay-Varina State:NC Zip: 27526-
Phone number: (919)625-0214 Email Address:jay(kmeyersen in�g,net
IV. WASTEWATER TREATMENT FACILITY(WWTF)INFORMATION:
1. Facility Name:North Harnett Regional WWTP Permit Number:NCO021636
Owner Name:Harnett Regional Water
V. RECEIVING DOWNSTREAM SEWER INFORMATION:
1. Permit Number(s):WQ0013496
2. Downstream(Receiving) Sewer Information: 8 inch Z Gravity ❑ Force Main
3. System Wide Collection System Permit Number(s)(if applicable):WQCS00193
Owner Name(s): Town of Fuquay-Varina
FORM:FTA 10-23 Page 1 of 5
VI. GENERAL REQUIREMENTS
1. If the Applicant is a Privately-Owned Public Utility,has a Certificate of Public Convenience and Necessity been attached?
[—]Yes [—]No ®N/A
2. If the Applicant is a Developer of lots to be sold,has a Developer's Operational Agreement(FORM:DEV)been attached`?
❑Yes [—]No ®N/A
3. If the Applicant is a Home/Property Owners'Association,has an HOA/POA Operational Agreement(FORM:HOA)and
supplementary documentation as required by 15A NCAC 02T.0115(c)been attached?
❑Yes ❑No ®N/A
4. Origin of wastewater: (check all that apply):
®Residential(Individually Owned) ❑ Retail(stores,centers,malls) ❑ Car Wash
❑Residential(Leased) ❑ Retail with food preparation/service ❑Hotel and/or Motels
❑ School/preschool/day care ❑ Medical/dental/veterinary facilities ❑ Swimming Pool/Clubhouse
❑Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash
❑Businesses/offices/factories ❑Nursing Home ❑ Other(Explain in Attachment)
5. Nature of wastewater: 100%Domestic %Commercial %Industrial(See 15A NCAC 02T.0103(20))
If Industrial,is there a Pretreatment Program in effect?❑Yes❑No
6. Hasa flow reduction been approved under 15A NCAC 02T.0114(f)? []Yes ❑No
➢ If yes,provide a copy of flow reduction approval letter with this application
7. Summarize wastewater generated by project:
Establishment Type(see 02T.0114(f)) Daily Design Flow',' No.of Units Flow
56 4-bedroom homes 75 gal/bedroom 224 16,800 GPD
gal/ GPD
gal/ GPD
gal/ GPD
gal/ GPD
gal/ GPD
Total 16,800 GPD
a See 15A NCAC 02T .0114(b), (d), (e)(1) and(e)(2) for caveats to wastewater design flow rates (i.e. proposed unknown
non-residential development uses; public access facilities located near high public use areas; and residential property
located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S.42A-4).
b Per 15A NCAC 02T.0114(c),design flow rates for establishments not identified[in table 15A NCAC 02T.01141 shall be
determined using available flow data,water using fixtures,occupancy or operation patterns,and other measured data.
8. Wastewater generated by project:0 GPD(per 15A NCAC 02T.0114 and G.S. 143-215.1)
➢ Do not include future flows or previously permitted allocations
If permitted flow is zero,please indicate why:
❑Pump Station/Force Main or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line.
Please provide supplementary information indicating the approximate timeframe for permitting upstream sewers with flow.
®Flow has already been allocated in Permit Number:WO0039197 Issuance Date: 05/08/2017
❑ Rehabilitation or replacement of existing sewers with no new flow expected
❑ Other(Explain):
FORM:FTA l 0-23 Page 2 of 5
VII. GRAVITY SEWER DESIGN CRITERIA(If Applicable)-02T.0305&MDC(Gravity Sewers):
1. Summarize gravity sewer to be permitted:
Size(inches) Length(feet) Material
8 2747 PVC&DIP
➢ Section II&III of the MDC for Permitting of Gravity Sewers contains information related to design criteria
➢ Section III contains information related to minimum slopes for gravity sewer(s)
➢ Oversizing lines to meet minimum slope requirements is not allowed and a violation of the MDC
VIII. PUMP STATION DESIGN CRITERIA(If Applicable)—02T.0305&MDC(Pump Stations/Force Mains):
PROVIDE A SEPARATE COPY OF THIS PAGE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT
1. Pump station number or name:Avery Crossing Pump Station
2. Approximate Coordinates(Decimal Degrees):Latitude: 35.5812' Longitude: -78.8277'
3. Total number of pumps at the pump station:2
3. Design flow of the pump station: 0.186 millions gallons per day(firm capacity)
➢ This should reflect the total GPM for the pump station with the largest pump out of service.
4. Operational point(s)per pump(s): 129 gallons per minute(GPM)at 51 feet total dynamic head(TDH)
5. Summarize the force main to be permitted(for this Pump Station):
Size(inches) Length(feet) Material
4 1545 PVC
If any portion of the force main is less than 4-inches in diameter,please identify the method of solids reduction per
MDCPSFM Section 2.01C.Lb. ❑ Grinder Pump ❑ Mechanical Bar Screen ❑ Other(please specify)
6. Power reliability in accordance with 15A NCAC 02T.0305(h)(1):
® Standby power source or ❑ Standby pump
➢ Must have automatic activation and telemetry- 15A NCAC 02T.0305(h)(1)(B);
➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day
➢ Must be permanent to facility and may not be portable
Or if the pump station has an average daily flow less than 15,000 gallons per day 15A NCACO2T.0305(h)(1)(C):
❑ Portable power source with manual activation,quick-connection receptacle and telemetry-
or
❑ Portable pumping unit with plugged emergency pump connection and telemetry:
➢ Include documentation that the portable source is owned or contracted by the applicant and is compatible with the station.
➢ If the portable power source or pump is dedicated to multiple pump stations,an evaluation of all the pump stations'storage
capacities and the rotation schedule of the portable power source or pump,including travel timeframes, shall be provided
as part of this permit application in the case of a multiple station power outage.
FORM:FTA 10-23 Page 3 of 5
IX. SETBACKS&SEPARATIONS—(02B.0200 & 15A NCAC 02T.0305(f)):
1. Does the project comply with all separations/alternatives found in 15A NCAC 02T.0305(f)&(g)? ®Yes [—]No
15A NCAC 02T.0305 contains minimum separations that shall be provided for sewers stems:
Setback Parameter* Separation Required
Storm sewers and other utilities not listed below(vertical) 18 inches
2Water mains(vertical-water over sewer preferred,including in benched trenches) 18 inches
2Water mains(horizontal) 10 feet
Reclaimed water lines(vertical-reclaimed over sewer) 18 inches
Reclaimed water lines(horizontal-reclaimed over sewer) 2 feet
**Any private or public water supply source,including any wells,WS-I waters of Class I or
Class II impounded reservoirs used as a source of drinking water,and associated wetlands. 100 feet
**Waters classified WS(except WS-I or WS-V),B, SA,ORW,HQW,or SB from normal
high water(or tide elevation)and wetlands associated with these waters(see item IX.2) 50 feet
**Any other stream,lake,impoundment,or ground water lowering and surface drainage
ditches,as well as wetlands associated with these waters or classified as WL. 10 feet
Any building foundation(horizontal) 5 feet
Any basement(horizontal) 10 feet
Top slope of embankment or cuts of 2 feet or more vertical height 10 feet
Drainage systems and interceptor drains 5 feet
Any swimming pools 10 feet
Final earth grade(vertical) 36 inches
➢ If noncompliance with 02T.0305(fl or(g), see Section X.1 of this application
*15A NCAC 02T.0305(a)contains alternatives where separations in 02T.0305(f)cannot be achieved.Please check"yes"
above if these alternatives are used and provide narrative information to explain.
**Stream classifications can be identified using the Division's NC Surface Water Classifications webpa e
2. Does this project comply with the minimum separation requirements for water mains? ❑Yes ❑No ®N/A
➢ If no,please refer to 15A NCAC 18C.0906(f)for documentation requirements and submit a separate document,
signed/sealed by an NC licensed PE,verifying the criteria outlined in that Rule.
3. Does the project comply with separation requirements for wetlands? ❑Yes ❑No ®N/A
➢ Please provide supplementary information identifying the areas of non-conformance.
➢ See the Division's draft separation requirements for situations where separation cannot be met.
➢ No variance is required if the alternative design criteria specified is utilized in design and construction.
4. Is the project located in a river basin subject to any State buffer rules? ❑Yes Basin name: ❑No
If yes,does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ❑ Yes ❑No
➢ This includes Trout Buffered Streams per 15A NCAC 213.0202
5. Does the project require coverage/authorization under a 404 Nationwide/individual permits ❑Yes ®No
or 401 Water Quality Certifications?
➢ Please provide the permit number/permitting status in the cover letter if coverage/authorization is required.
6. Does project comply with 15A NCAC 02T.0105(c)(6)(additional permits/certifications)? ®Yes [—]No
Per 15A NCAC 02T.0105(c)(6),directly related environmental permits or certification applications must be being prepared,
have been applied for,or have been obtained.Issuance of this permit is contingent on issuance of dependent permits(erosion
and sedimentation control plans,stormwater management plans,etc.).
7. Does this project include any sewer collection lines that are deemed"high-priority?" ❑Yes ®No
Per 15A NCAC 02T.0402,"high-priority sewer"means any aerial sewer,sewer contacting surface waters,
siphon,or sewers positioned parallel to streambanks that are subject to erosion that undermines or deteriorates the sewer.
Siphons and sewers suspended through interference/conflict boxes require a variance approval.
➢ If yes,include an attachment with details for each line,including type(aerial line,size,material,and location).
High priority lines shall be inspected by the permittee or its representative at least once every six-months and
inspections documented per 15A NCAC 02T.0403(a)(5)or the permittee's individual System-Wide Collection permit.
FORM:FTA 10-23 Page 4 of 5
X. CERTIFICATIONS:
I. Does the submitted system comply with 15A NCAC 02'r,the Minimum Design Criteria for the Permitting of Pump Stations
and Force Mains(latest version),and the Gravity Sewer Mommum Design Criteria(latest version)as applicable?
®Yes ❑No
If no, for projects requiring a single variance, complete and submit the V ari ance/A Item ative Design Request application
(VADC 10-14) and supporting documents for review to the Central Office. Approval of (hit reauest will be (sued
concurrently with the approval of the permit,and oroiccts reauiring a variance approval av be subject to longer
review times.For proleets requiring two or morf,yariances or where the variance is determined by the Division to be a
significant portion of the prooSct,the full technical review is required,
2. Professional EngincccesCertification;
1, �ay rIJ•l ecY attest that this application for Mee
(Professio Engviecr's n4 from Application Item 111.1) (Project amc from Applical n em U.1)
has been reviewed by me and is accurate, complete and consistent with the information supplied In the plans,
specifications,engineering calculations,and all other supporting documentation to the best of my knowledge. I further
attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations,
inimum Qesign Criteria for Gravity Sewers(latest version).and the Minimum Design Criteria for the Fast-Tragk Permitting
of Pump Stations and Force Mains(latest version). Although other professionals may have developed certain portions of this
submittal package,inclusion of these materials under my signature and seal signifies that I have reviewed this material and
have judged it to be consistent with the proposed design.
NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false
statement,representation,or certification in any application package shall be guilty of a Class 2 misdemeanor,which may
include a fine not to exceed 510,000,as well as civil penalties up to$25,000 per violation.Misrepresentation of the application
information,including failure to disclose any design non-compliance with the applicable Rules and desi n criteria,may subject
the North Carolina licensed Professional Engineer to referral to the licensing board.(21 NC I ////�
p�. ;
North Carolina Professional Engineer's seal,signature,and date: � `�� •$/
SEAL
~ 19790 i
3. Applicant's Certification per 15A NCAC 02T.0106(b):
1, Michael Wagner —,attest that this application for Avery Crossing Modification
(Signature Authority Name from Application Item 13) (Project Name from Application Item IL1)
attest that this application has been reviewed by me and is accurate and complete to the best of my knowledge.
I understand that if all required parts of this application are not completed and that if all required supporting documentation
and attachments are not included,this application package is subject to being returned as incomplete. I understand that any
discharge of wastewater from this non-discharge system to surface waters or the land will result in an immediate enforcement
action that may include civil penalties,injunctive relief,and/or criminal prosecution. I will make no claim against the Division
of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application
package are not completed and that if all required supporting information and attachments are not included,this application
package will be returned to me as incomplete.
NOTE In accordance with General Statutes 143-215.6A and 143-215.69, any person who knowingly makes any false
statement, representation,or certification in any application package shall be guilty of a Class 2 misdemeanor, which may
include a fine not to exceed 510,000 as well as civil penalties up to$25,000 per violation.
Signature: _ — Date: 03/25/2024
FORM:FTA 10-23 Page 5 of 5
I
NC Dept.of Environmental Quality
May 16 2024
1 1(�r(� U.S.DEPARTMENT OF THE INTERIOR FUQUAY-VARINA QUADRANGLE
Z USGS U.S.GEOLOGICAL SURVEY '�a NORTN 1AROLNA
eMae�wwww ..USTopo Raleigh Regional Office J.5-MINUTE
o Q9
gs.bxs9 °93w°"'E 9I 95 96 97 98 99 00 01 02 03 Js.bxs9
�wanN
g
43 \ �I
1 a
° - s«D � � 4l
1 8 Y roc.
4242
e`
§ ¢
- O
- °vxs �w ve`Poiv�ae\
41
• = qx
"' sr.ren'ucn s t4 eev°m'sr {" °
1 o I
Q R 2 4
°
+ °
Iw r
d0 a INA VAR
p°°e bio'x° 40
1 � i
ew
xs.
r e.
� r
39 3a
o
\ wsHs
o no wr*n 0 9u
39
38 /y5x i��ti.\ 'sn`gesryn wbg wO £' 3R
j � C 37
p �
y wr.sau� Y
e -
O Q 31
Avery Crossing
36
Pump Station Site
Ib
35
35
u 0 O 34
33 aae,a O � A4 C O ea 4$w \x 33
32
p
32
JS 0 x
i 'e
I w
" ar uerx
xsr
31
✓ O � �s31ao.N
Js.s ne,w 93 94 95 9E 97 a 98 99 M, 00 �, Ot 02 03 4",e .soap
ceU by�Ne UniteO States Geological Survey SCALE 1:24 000 x0n9 cu
� nww may.m e.n a wws -
-_
urras°.xo.°�.e.aMcxan« rtn
... ........
FUQUAY-VARINA.NC
2022
Fuquay-Varina GIS [Toi^ NAI.k�ite ] : P V'_-+t:
II
+ Or Select a Search Category 01 4
o
00
so
.24
qI
OIL.P
M• 1�„
1 S•fin . � Rd v ''�r i. ���� ,rr
S w � • ro � .,�1 � t ,t
• '�►"f..
Existing Avery a Q�M- ' J• e`wP
Crossing Pump
Station
• ` •,
q y�'rY G'1r^�• ` � 7
AVER•Y � ` � • ;
•ROSSIN ®rz
F• t x
Fleming Woods Ln / 1. ' • •�i� •' .� , ,t�"r � ' t1� x �.
NC Dept. of Environmental Quality
May 16 2024
Raleigh Regional Office app state
Click to restore the m T extent and layers
400ft visibility where you left off.
n - '
.+
Subdivision
Yli .
"NU
�r
xisting Ave
Crossing Pump
Station
IL
mw
Jon
���• r `��
� ' a
ll
Southern Oaks
Pump Station
O
. • ► s
iI^ �... ► . ■ sSouthern Oaks GS
•
Phase 11
� it __a.� +. _ �� • r `�•J !! � ��'.. .�.l- �
kj
:-fv 1,U0
41
Southern Oaks GS
Phase I
P
• 11 ' •
ArCGIS Web Map
f ft
z
(61
n
Avery Crossing
PS approximate
location
i
r
z.?5 -
XtAS
ENGINEERIN, Pi LC
PROJECT NARRATIVE
Date: March 5,2024 \```���ttit111rrrrrrrrr���
A t?01
To: NCDEQ-DWR
3800 Barrett Drive
Raleigh,North Carolina 27609 SEAL
19790 _
i s
From: Jay Meyers, PE 05-W
Subject: Avery Crossing PS Upgrade
WQ0039197 Permit Modification
McKee Homes,LLC is proposing an 83-lot subdivision named Holston Subdivision at 2406 Fleming
Road in the Town of Fuquay-Varina. The Holston Subdivision's projected average day sewage now is
24,900 gallons per day(gpd)based on 75 gpd/bedroom and 83 4-bedroom single family homes. Using a
2.5 peaking factor this results in a peak flow of 43.2-gpm.
The proposed development is tributary to the Avery Crossing Pump Station(WQ0039197). The Avery
Crossing Pump Station was permitted as part of the Avery Crossing Subdivision and included the
following infrastructure—"construction of approximately 2,747 LF of 8"gravity sewer, an 80 GPM pump
station with duplex pumps, approximately 1,545 LF of 4"FM,and 16,800 GPD of domestic wastewater".
The Avery Grossing subdivision is a 56-lot subdivision that has been built out. The 56 4-bedroom homes
would generate a peak flow of 29.2 gpm.
In addition to the flow from the proposed Holston Subdivision,a 114-unit townhome project is in initial
planning stages on the adjacent Weeks property that would also be served by the Avery Crossing Pump
Station. Using the recently regulatory change to 75-gpd/bedroom for a dwelling unit and assuming 3-
bedroom town homes,the proposed townhouse development would generate a projected average day
sewage flow of 25,650 gpd and a peak flow of 44.5 gpm. Other tributary properties could generate 12.1-
gpm of additional peak flow.
The total peak flow to the Avery Crossing pump Station would be:
Avery Crossing Subdivision - 29.2-gpm
Holtson Subdivision- 43.2-gpm
Town Home Development 44.5-gpm
Potential Tributary Flow- 12.1-gpm
Total- 129-gpm
Meyers Engineering,PLLC
5708 Carriage Park Court/Ftquay-Varina,NC 27526/919-625-0214
MowYER
The proposed project is to increase the pumping capacity of the existing pump station by replacing
existing pumps with new pumps able to pump at a greater rate. The minimum pumping rate for the
increase would be 129-gpm with a total dynamic head(TDH)of 51-feet.
The pump change will require modifications to the pump station interface control panel including starters,
circuit breakers,and overload heaters for the new pumps.
Requested Action
Approve WQ0039197 Permit Modification to increase the pump station pumping rate from 80-gpm to a
129-gpm at 51-feet'rDH with a project zero flow since flows will be permitted under separate
applications.
Meyers Engineering,PLLC
5708 Carnage Park Courl/Puquay-Varina,NC 27526/919-625-0214
Page 2 of 2
Elaine Wild<elaine.wiid@deq.nc.gov> 3/5/2024 3:34 PM
RE: [External] permit modification - NCCePi 0;E;v,roi:,re=1ia)
To jay@meyersengineering.net<)ay@meyersengineering.net> Copy
SVC_DEQ.DWR.RRO.FastTracks <deq.dwr.rro.fasttracks@deq.nc.gov>
APR 32024
Hello Jay, 3OIlALI)rrl00c"��offICC
Can you send me a digital copy of the original permit? The Avery Crossing sewer extension permit WQ0039197 is
available on the Laserfiche Public Portal, link provided below for your convenience.
WWQ0039197 Permit(lssuance)_20170508
Also,since the flows for the modification are addressed in FTSE's for the Holston Subdivision,can those some FTSE's
accompany this modification request?
According to the existing permit, W0.0039197,the permitted flow is 16,800 GPD of domestic wastewater. ;f the
viiiy change! for th2 =c�`,caliWl of WQ0039197 is to increase the Size of the pumps at the pump station (PS) to
�ccc�rYunoda ; �i ,.,t3.,.•�f iii i7ri'tiiurl Ribciivision that is already ailorotar!with (lie receiver), then no FTSEs am
nNeded We do not want to double allocate the flow of HS so be sure to specify the reasoning for the
modification in the narrative for Avery Crossing is for PS replacement only.
And lastly,since it a modification,do you need a USGS map as well to accompany the modification application. Every permit
application, new or modification, needs to include all aspects of the application according to the FTA,
application instructions,02T Rules,and the MDCs. The FTA should include all infrastructure that is expected to
be in tlxr final design of the permit. The narratives where you would indicate what was previously permitted
and what is to be changed as part of the modification.
Please note that I have transitioned to another position within the Division of Water Resources and am no
longer in the Raleigh Regional Office. However, I will be retaining and completing any outstanding Fast Track
Sewer Extension permit applications that I have begun. ! have copied the Raleigh Regional Office Fast Track
Team on this emai for your convenience and notification to them of the future modification submittal for Avery
Crossing,WQ0039197. All future general fast track sewer extension related inquiries should be directed to the
Raleigh Regional Office Fast Track Team via email at DE .DWR.RRO.F T a k •deg nc go.
Best Regards,
Elaine Wild
Environmental Engineer
Division of Water Resources—NPDES Industrial Permitting Unit
North Carolina Department of Environmental Quality
�i "HVEU
1): c-m-V R troy COOPER
Governor
r ' MICHAEL E. REGAN
Sruornry
I•ty H yr 1' nc� I:'r S. JAY ZIMMERMAN
Water Resources
I NVI"ONMENTA!OVAIITY
May 8,2017
]ay T. Meyers,P.E,Public Utilities Director
Town of Fuquay-Varina
401 Old Honeycutt Road
Fuquay-Varina, NC 27526
Subject: Permit No.WQ0039197
Town of Fuquay-Varina
Avery Crossing
Wastewater Collection System Extension Permit
Wake County
Dear Mr.Meyers:
In accordance with your application received March 29,2017,and additional information received on May
3,2017,we are forwarding herewith Permit No.WQ0039197 dated May 8,2017,to the Town of Fuquay-
Varina {Permittee} for the construction and operation upon certification of the subject wastewater
collection system extension. This permit shall be effective from the date of issuance until rescinded and
shall be subject to the conditions and limitations as specified therein.This cover letter shall be considered
a part of this permit and Is therefore incorporated therein by reference.
Please pay particular attention to the following conditions contained within this permit:
Condition 1.1: Each pump station shall be clearly and conspicuously posted using a weatherproof sign
with a pump station identifying name/number, 24-Hour Emergency telephone number,
and name of the owner/operator of the sewer system/pump station and instructions to
call the number In the event of alarm activation or other emergency.
Condition 11.1: This permit shall not he automatically transferable; a permit modification request for a
name change must first be approved by this office.
Condition 11.4: Requires that the wastewater collection facilities be properly operated and maintained
in accordance with 15A NCAC 2T.0403 or any individual system-wide collection system
permit issued to the Permittee,
It shall be the responsibility of the Permittee to ensure that the as-constructed project meets the
appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North
Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement
wastewater collection facilities, and/or referral of the North Carolina-licensed Professional Engineer to
the licensing board.
If any parts, requirements,or limitations contained in this permit are unacceptable,you have the right to
request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This
Division of Water Resource;,Ruleigh Re,�nma l Office,lv.ucr Quality Operntiens Scelion www.ncwatcrquality.org
1628 Anil Service Center,Rnlalgh,NIC 27699-16.3 Phone:(919)791.4200
1_ncalinn: 100 Bancll Drive Rnluieh.W'27609 Fax-.(919)793-715n
Town of Fuquay-Varina
Permit No.W00039197
request must be in the form of a written petition,conforming to Chapter 150B of North Carolina General
Statutes, and filed with the office of Adminisiral1w, Hearings, 6714 Mail Service Center, Raleigh, NC
27699-6714. Unless Sirch demands are made,this Kermit shall be final and binding.
If you need additional Information concerning this matter,please contact Ted Cashion at(919)791-4254
or via e-mail at Leci.cashion[ortcdenr.gov.
Sincerely,
for S.Jay Zimmerman,P.G.
Director, Division of Water Resources
by S.Daniel Smith, Regional Supervisor
Water Quality Regional Operations Section
Raleigh Regional Office
Division of Water Resources, NCDEQ
cc; James David Arnold, P.E.,The Nau Company,PLLC, P.O. Box 810, Rolesville, NC 27571
Wake County Health Department
Raleigh Regional Office files
Water Resources Central Files
Steve Ward, Harnett Co.Dept.of PUbIiL utilities,P.O.Box 1119, Lillington, NC 27546
Fayetteville Regional Office,Surfare Water Protection Section
Page 2 of 8
North Carolina Department of Environmental Quality
STATE OF NORTH CAROLINA
ENVIRONMENTAL MANAGEMENT COMMISSION
DEPARTMENT OF ENVIRONMENTAL QUALITY
WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT
In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as
amended,and other applicable Laws, Rules,and Regulations,permission is hereby granted to the
Town of Fuquay-Varina
Wake County
for the construction and operation of approximately 2,747 linear feet of 8-Inch gravity sewer,an 80 gallon
per minute pump station with duplex pumps,on-site audible and visual high water alarms,telemetry,and
a permanent generator with automatic transfer switch, as well as approximately 1,545 linear feet of 4-
inch force main to serve 56 four-bedroom homes as part of the Avery Crossing project,and the discharge
of 16,800 gallons per day of collected domestic wastewater Into the Town of Fuquay-Varina's and Harnett
County's existing sewerage system, pursuant to the application received March 29,2017,and additional
Information received on May 3,2017,and In conformity with 15A NCAC 2T; the Division's Gravity Sewer
Minimum Design Criteria adopted February 12, 1996 and updated In March 2008, as applicable; the
Division's Minimum Design Criteria for the Fast-Track Permitting of Pump Stations and Force Mains
adopted June 1, 2000 and updated March 2009, as applicable; and other supporting data subsequently
filed and approved by the Department of Environmental Quality and considered a part of this permit.
This permit shall be Znsivf_V
e date�of' nce until rescinded and shall be subject to the specified
conditions limi
14
S.Jay Zimmerman, P.G.
Director,Division of Water Resources
By Authority of The Environmental Management Commission
Permit Number: WQ0039197
Permit Issued: May 8, 2017
Page 3 of 8
r%IC Dert of Envircr:,;antzl Qn(;ry
N&YERS
APR 3 20?4 ENGINEERING, PLLC
LETTER OF TRANSMITTAL
To: NCDEQ/DWR
Water Quality Permitting
PERCS Unit Physical Address
1617 Mail Service Center 512 N Salisbury (F �� � EIVED
Raleigh, North Carolina 27699-1636 Raleigh, North Car 0
Attention: Matthew Nevills, Environmental Specialist A f 01 O�4
Project: Avery Crossing Permit Modification (WQ0039197�CDEQ/DWR/WDES
Date: March 25, 2024
Submittal Quantity Date Description
Application 2 03/20/2024 NCDEQ-DWR Form SSEA 04-16
Permit 2 05/08/2017 Copy of WQ0039197
Map 2 Project Location
Doc 2 03/05/2024 Project Narrative
Email 2 03/05/2024 From Elaine Wild regarding FTSE forms
Check 1 Application Fee-$600
For: Review and Approval
Meyers Engineering,PLLC
5708 Carriage Park Court,,Puquay-Varina,NC 275261919-625-0214