Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0024720_Engineering Certification_20240528
Initial Review Reviewer nathaniel.thornburg Is this submittal an application? (Excluding additional information.) * Yes No If not an application what is the submittal type?* Annual Report Residual Annual Report Additional Information Other Engineering Certification Permit Number (IR) * W00024720 Applicant/Permittee Cody Parker and Joy Parker Email Notifications Does this need review by the hydrogeologist? * Yes No Regional Office CO Reviewer Admin Reviewer Submittal Form Project Contact Information Please provide information on the person to be contacted by NDB Staff regarding electronic submittal, confirmation of receipt, and other correspondence. ......................................................................................................................................................................................................................................................................................... ... ... ... ... ... .. ... ... ... ... .. Name* Tyler S MacConnell Email Address* tylermacconnell@macconnellandassoc.com Project Information ......................... Application/Document Type* New (Fee Required) Modification - Major (Fee Required) Renewal with Major Modification (Fee Required) Annual Report Additional Information Other Engineering Certification Phone Number* 9194671239 Modification - Minor Renewal GW-59, NDMR, NDMLR, NDAR-1, N DAR-2 Residual Annual Report Change of Ownership We no longer accept these monitoring reports through this portal. Please click on the link below and it will take you to the correct form. https:Hedocs.deq.nc.gov/Forms/NonDischarge Monitori ng_Report Permit Type:* Wastewater Irrigation High -Rate Infiltration Other Wastewater Reclaimed Water Closed -Loop Recycle Residuals Single -Family Residence Wastewater Other Irrigation Permit Number: * WQ0024720 Has Current Existing permit number Applicant/Permittee Address* 501 Cascade Pointe Lane, Suite 103 Facility Name * 10311 Rougemont Rd. SFR Please provide comments/notes on your current submittal below. Attached you will find Engineer Certification and Record Drawings. At this time, paper copies are no longer required. If you have any questions about what is required, please contact Nathaniel Thornburg at nathaniel.thornburg@ncdenr.gov. Please attach all information required or requested for this submittal to be reviewed here. (Application Form, Engineering Plans, Specifications, Calculations, Etc.) Engineer Certification Letter and Record Drawings - 3.59MB W00024720.pdf Upload only 1 PDF document (less than 250 MB). Multiple documents must be combined into one PDF file unless file is larger than upload limit. * By checking this box, I acknowledge that I understand the application will not be accepted for pre -review until the fee (if required) has been received by the Non -Discharge Branch. Application fees must be submitted by check or money order and made payable to the North Carolina Department of Environmental Quality (NCDEQ). I also confirm that the uploaded document is a single PDF with all parts of the application in correct order (as specified by the application). Mail payment to: NCDEQ — Division of Water Resources Attn: Non -Discharge Branch 1617 Mail Service Center Raleigh, NC 27699-1617 Signature Submission Date 5/28/2024 Permit No. WQ0024720 Single -Family Residence Wastewater Irrigation System Cody Parker and Joy Parker February 16, 2023 10311 Rougemont Rd. SFR Durham County ENGINEERING CERTIFICATION ❑ Partial Final I,6n�� S. M L° 1 c l j , as a duly licensed North Carolina Professional Engineer, having ❑ periodically / fully observed the construction of the permitted facilities, do hereby state to the best of my abilities tat the facility was constructed in compliance with G.S. 143-215.1. Administrative Code Title 15A Subchapter 02T, this permit, and the Division -approved plans and specifications. Documentation of any variation to this permit and the Division -approved plans and specifications is in the attached as -built drawings. Description of variations: 5 `� A 71" V 64- -1 0 d !. t f &0 A H" c �cl_ isNf h S- 2f Professional Engineer's Name Firm Name Firm No. Sol Address is ' '••� fNGINE��`•' ���. iMA�J/7UM THE PERMITTEE SHALL SUBMIT THE COMPLETED ENGINEERING CERTIFICATION, INCLUDING ALL SUPPORTING DOCUMENTATION, VIA THE NON -DISCHARGE ONLINE PORTAL. W00024720 Version 3.1 Shell Version 230130 Page 9 of 9 0 cz o_ 0 0 0 L0 00 O N N O N c� U N a COPYRIGHT 0 2022-2024 CO Y JOY PARKER VICINITY MAP SURFACE SPRAY IRRIGATION WITH E—Z TREAT CONVERSION PROJECT No. A08501.00 10311 ROUGEMONT ROAD DURHAM COUNTY, NC PARCEL #: 189425 SCHEDULE OF DRAWINGS: C-100 COVER SHEET C-101 GENERAL NOTES C-102 SYSTEM SCHEMATICS & MAINTENANCE SCHEDULE C-103 OVERALL SITE PLAN C-104 PROPOSED SYSTEM LAYOUT C-105 TREATMENT SYSTEM DETAIL KEY C-106 TREATMENT TABLE D-101 DETAILS 1 OF 7 D-102 DETAILS 2 OF 7 D-103 DETAILS 3 OF 7 D-104 DETAILS 4 OF 7 D-105 DETAILS 5 OF 7 D-106 DETAILS 6 OF 7 D-107 DETAILS 7 OF 7 W W O > W 0 N U zz 00 � � U W W Z X EEZ a w0 z o �W Cc) a W 2 � U N � O a W U u-2 n A m O N m � O N mo 00 Oa o� -0m2 x c c �o �� W N in N Z J � Z z 0) = �O—aX W �XSIQi zU o00�o a'�z� 2 oza�� v SIT � CO �J o OW U LOCATION MAP THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, THE DESIGN PROFESSIONAL CANNOT ASSURE ITS ACCURACY, AND THUS IS NOT RESPONSIBLE FOR THE ACCURACY OF THIS RECORD DRAWING OR FOR ANY ERRORS OR OMMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO IT AS A RESULT. THOSE RELYING ON THIS RECORD DOCUMENT ARE ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE. RECORD DRAWING MAY 09, 2024 A . O " CA 51201 GINS G �. E cm 0 Lo 0 v N O N O c m 75 (D m 0 0 0 o 00 0 0 0 0 0 0 U m Q U) E cm 0 tr 0 E 0 tr 0 0 0 `D 15 cm IZ O O 0 Lo 0 O N N O N c� cn U N a ro GENERAL NOTES J O 1. CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF ALL TRADES AND SUBCONTRACTORS. CONTRACTOR IS ALSO RESPONSIBLE FOR FIELD VERIFYING DIMENSIONS, ELEVATIONS, AND LOCATIONS OF w W ALL EXISTING CONDITIONS AND UTILITIES. SITE RESTORATION � Lu Z O V 2. CONTRACTOR IS RESPONSIBLE FOR INSTALLING SYSTEM IN ACCORDANCE WITH ALL STATE & LOCAL REGULATIONS & POLICIES. W Z 3. CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE SOIL EROSION AND SEDIMENTATION CONTROL REQUIREMENTS. 1. BACKFILL WITH SUITABLE LOOSE MATERIAL (SANDY LOAM TO SANDY CLAY LOAM) FREE OF LARGE OR 4. CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE OSHA, NCDOT AND LOCAL SAFETY REQUIREMENTS. DAMAGING OBJECTS, SEED AND STRAW BACKFILLED AREAS (OR SOD WHEN REQUIRED). 5. CONTRACTOR IS RESPONSIBLE FOR REPAIRING ALL CONSTRUCTION DAMAGE EXPEDITIOUSLY AND AT NO ADDITIONAL COST TO THE OWNER. 2. PROVIDE EROSION PROTECTION FOR BACKFILL MATERIAL IN ACCORDANCE WITH STATE AND COUNTY 6. LAYOUT OF THE APPLICATION AREA IS BASED ON ORIGINAL DESIGN (DUANE K. STEWART, INC) STANDARDS AND MAINTAIN UNTIL PERMANENT PROTECTION IS ESTABLISHED. Z Z 7. DRAIN ALL ROOF AND TOE DRAINS AWAY FROM SPRAY FIELD AND TREATMENT UNITS. 3. BACKFILL SHOULD BE GRADED TO PREVENT THE INFILTRATION OF SURFACE WATER AND DIVERT STORM 0 0 8. PROVIDE MINIMUM 100 FEET OF SEPARATION FROM ANY WELL TO WASTEWATER TREATMENT UNITS AND DISPOSAL SYSTEMS IF APPLICABLE. WATER RUN-OFF AWAY FROM THE SYSTEM. WHEN ADDITIONAL FILL IS REQUIRED, IT SHOULD BE PLACED a U 9. WASTEWATER AND IRRIGATION SYSTEMS SHALL COMPLY WITH IWWS-2015-3-R2 AFTER SYSTEM IS INSTALLED FROM THE EDGES CROWNED IN THE MIDDLE AND FEATHERED OUT 10' Y 0 Lu Z 10. ALL PIPE SHALL BE SCHEDULE 40 PVC UNLESS OTHERWISE NOTED. BEYOND THE DISPERSAL AREA. FILL SHOULD BE TEXTURE GROUP II OR III AND FREE OF LARGE STONES w w z } H 11. INSTALLER IS RESPONSIBLE FOR ENSURING DISPERSAL AREA WAS PROPERLY CLEARED & SOIL MOISTURE CONDITIONS ARE CONDUCIVE FOR INSTALLATION PRIOR TO BEGINNING INSTALLATION. AND ORGANIC DEBRIS. TOP 2" SHOULD BE SUITABLE FOR ESTABLISHMENT OF LAWN. d O Z 12. EJECTOR PUMP MAY BE REQUIRED FOR BASEMENT FIXTURES. INSTALLER IS RESPONSIBLE FOR VERIFICATION. 13. KEEP ALL EXCAVATIONS 20' FROM INSTALLATION AND RESERVE AREA. TREATMENT UNITS 0 LU 14. KEEP WELL AND SEPTIC SYSTEM OUT OF ANY UTILITY EASEMENTS AND AT LEAST 10' FROM UTILITY LINES. < °� F_ Q 15. DO NOT INSTALL LAWN IRRIGATION SYSTEMS WITHIN 20 FEET OF DISPERSAL AREA. 1. SYSTEM INSTALLATION MUST COMPLY WITH ALL LOCAL ORDINANCES AND POLICIES. LU N. 16. DO NOT CONNECT WATER TREATMENT SYSTEMS, CONDENSATIONS DRAINS OR SUMP PUMPS TO ONSITE SYSTEM. 0 a LLI LL 17. IF A PRE-CONSTRCTION MEETING REQUIRED BY PERMIT, PLEASE CALL TO SCHEDULE. 18. ANY DEVIATION FROM THIS DESIGN MUST BE APPROVED BY THE LOCAL HEALTH DEPARTMENT AND THE ENGINEER PRIOR TO INSTALLATION. 19. ELECTRICAL WIRING SHOULD BE INSTALLED BY A LICENSED ELECTRICAL CONTRACTOR, ACCORDING TO NEC, STATE AND LOCAL ELECTRICAL CODES, AS APPLICABLE. 20. CONTRACTOR IS TO INSTALL TANKS ON UNIFORMLY FIRM AND STABLE COMPACTED GROUND, CRUSHED STONE IS RECOMMENDED TO PROVIDE UNIFORM SUPPORT TO TANK BOTTOM ESPECIALLY IN OPERATING REGIME FOR SPRAY IRRIGATION SYSTEM POOR, WET OR ROCKY SOILS. SYSTEM IS DESIGNED AND CONTROLS (MICROPROCESSORS) ARE PROVIDED TO DOSE THE E-Z TREAT m O 041. 21. ALL TANKS MUST BE WATER -TIGHT AND CONFORM TO APPLICABLE LOCAL AND STATE REGULATIONS AND POLICIES. Q O cV 22. ALL PVC JOINTS SHALL BE PRIMED AND CHEMICALLY FUSED UNLESS THREADED. TREATMENT UNITS. SEE SHEET C-102 FOR "ON" AND "OFF" TIME SETTINGS. PUMPED SPRAY IRRIGATION coN O 23. MAXIMUM COVER OVER TANKS AND DISTRIBUTION BOXES VARIES BY MANUFACTURER AND COUNTY. FLOW SHALL PASS THROUGH A FLOW METER. WHEN THE PREPROGRAMMED VOLUME IS REACHED THE Lo co Lu m O ~ ap 24. DISPERSAL FIELD CORNERS OR PROPERTY CORNERS SHOULD BE MARKED PER ORIGINAL DESIGN ACTIVE PUMP WILL BE DE -ENERGIZED. THE PUMP WILL ALSO DE -ENERGIZE IF THE LOW WATER LEVEL m m 2 0 Q 0 O 25. SHALLOW PLACED SYSTEMS (LESS THAN 18") MUST BE HAND CLEARED AND STUMPS GREATER THAN 6" IN DIAMETER MUST BE GROUND OUT. STUMPS LESS THAN 6" MAY BE CAREFULLY "PUMP OFF" SWITCH IS ACTIVATED. SEE DUANE K. STEWART & ASSOCIATES, INC. DRAWINGS FOR FIELD REMOVED ON THE DAY OF INSTALLATION. DOSING INFORMATION. c CD 0 26. REFER TO SITE DRAWING FOR ANY SPECIAL REQUIREMENTS. 2. IF THE HIGH WATER LEVEL "ALARM" FLOAT SWITCH IS ACTIVATED, THE SYSTEM WILL BEGIN ITS OPERATION i n 27. MACHINERY SHOULD AVOID PERCOLATION AREA. OF DELIVERING THE PREDETERMINED DOSE VOLUME, AND SHALL ALSO ENERGIZE THE AUDIBLE AND FLASHING ? ^ Q M 28. MACHINERY SHOULD NOT TRAVERSE EXCAVATED/EXPOSED PERCOLATION AREA. ALARM FIXTURES (ONCE ENERGIZED, THE FLASHING AND AUDIBLE ALARM UNITS WILL ONLY BE RESET O 04 Z - 29. ALL SUPPLY AND RETURN LINES NOT DESIGNED TO DRAIN BACK SHOULD BE PROTECTED FROM FREEZING. MANUALLY OR BY REACHING LOW LEVEL CONDITIONS). J LLI Z Z _ rn m = 3. THE CONTROL PANEL SHALL INCLUDE, BUT NOT BE LIMITED TO, AN "AUTO/MANUAL" SYSTEM CONTROL g p 04 Q X SWITCH, STOP/START SWITCH FOR EACH PUMP, NON-RESETTABLE ELAPSED TIME RECORDER FOR EACH U H Q 0 = LL Z U m rn PUMP, AND INDIVIDUAL PUMP RUN LIGHTS. 4. THE CONTROL PANEL SHALL BE A NEMA 4X ENCLOSURE. ALL SUPPORTING CONTROL UNITS, IF NOT a 0 Z 04 a HOUSED WITHIN THE CONTROL PANEL, SHALL BE IN A SEPARATE NEMA 4X ENCLOSURE. p Z J m ELECTRICAL NOTES L) � > F aQ �` 1. TWO DIFFERENT CONTROL PANELS WILL CONTROL THE WASTEWATER SYSTEM. ONE CONTROLS THE PRETREATMENT, AND ONE CONTROLS THE ULTRAVIOLET DISINFECTION. CONTRACTOR MAY USE U U COMBINED PANEL BY E-Z TREAT. CD 0 H 2. EACH PANEL SHALL BE APPROXIMATELY 13" WIDE X 15" HIGH AND IS A NEMA 4X, UL RATED ENCLOSURE. THE PANELS SHALL BE SUPPLIED BY THE SYSTEM DISTRIBUTOR. 3. THE PANELS SHALL BE MOUNTED BY THE ELECTRICIAN WITHIN 10' OF THE TANK UNITS. THEY SHALL BE MOUNTED NEXT TO EACH OTHER AND 48" - 60" OFF THE FINISHED GRADE TO THE BOTTOM OF THE ENCLOSURE. 4. THE INSTALLER'S ELECTRICIAN SHALL MAKE THE INTERNAL PANEL CONNECTIONS OF THE PUMP/UV AND CONTROL CORDS. EACH CONTROL PANEL SHALL CONTAIN A WIRING SCHEMATIC 1 /1 IDENTIFYING ALL TERMINAL CONNECTIONS. THE SYSTEM INSTALLER SHALL BUNDLE AND MARK EACH CORD WITH THE APPROPRIATE IDENTIFICATION AND SECURE IN THE ACCESS RISER AT THE DIFFERENT PUMP/UV POINTS. 5. CONTROL PANEL REQUIRES A DEDICATED CIRCUIT OF 20 AMPS, 115 VOLTS, SINGLE PHASE SUPPLIED FOR THE PUMP. F�1 6. CONTROL PANEL REQUIRES A DEDICATED CIRCUIT OF 20 AMPS, 115 VOLTS SUPPLIED FOR THE BOTH ALARMS. 7. CONTROL (DRIP) PANEL REQUIRES A DEDICATED CIRCUIT OF 20 AMPS, 115 VOLTS, SINGLE PHASE SUPPLIED FOR THE PUMPS. • ^� 8. CONTROL PANEL REQUIRES A DEDICATED CIRCUIT OF 30 AMPS, 115 VOLTS SUPPLIED FOR SOLENOID VALVE HEATER. ►�������� THESE RECORD DRAWINGS HAVE BEEN PREPARED BASEDUPON O 0 9. THE ULTRAVIOLET DISINFECTION UNIT REQUIRES A DEDICATED CIRCUIT OF 20 AMPS, 115 VOLTS. INFORMATION FURNISHED BY OTHERS. WHILE DESIGN INFORMATIONC A R ROF SSTION I BELIEVED TO BERE s Co RTHE ND THUS U1 10. A MINIMUM CONDUIT SIZE OF 1 36" SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICIAN AS A CONNECTION BETWEEN EACH CONTROL PANEL AND THEIR RESPECTIVE TERMINATION POINTS IRELIABLE,o''•. CANA IS O``,(N NOT RESPONSIBLE FOR THE ACCURACY OF THIS RECORD • / DRAWING OR FOR ANY ERRORS OR OMMISSIONS WHICH MAY V1 OUT IN THE TANK AREA. c) O��SS� HAVE BEEN INCORPORATED INTO IT AS A RESULT. THOSE 11. ALL OPEN CONDUIT ENDS SHALL HAVE REMOVABLE CLAY TYPE DUCT SEAL EMBEDDED TO PREVENT GASSES AND MOISTURE FROM ENTERING THE CONTROL PANELS. DO NOT USE PERMANENT SILICONE OR EXPANDABLE FOAM PRODUCTS. RELYING ON THIS RECORD DOCUMENT ARE ADVISED TO OBTAININDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE. r 12. ALL PUMP AND FLOAT CONTROL CORDS SHALL BE SUPPLIED WITH EITHER 30' OR 50' LEADS. THIS WILL HELP KEEP SPLICES TO A MINIMUM AND SHOULD BE AVOIDED IF AT ALL POSSIBLE. IF RECORD DRAWING 51201 A SPLICE MUST BE USED, IT MUST BE MADE ABOVE GRADE IN A PLASTIC NEMA 4X JUNCTION BOX. MAY 09, 2024 O 13. ALARMS SHALL BE AUDIBLE AND VISUAL. INE�� �i� 9� '��� �� 14. AUDIBLE/VISIBLE ALARMS SHALL BE EXTERNAL TO ANY STRUCTURE. C, BPS ���` MAINTENANCE SCHEDULE TIER FF SEPTIC TANK 3 - 6 MONTHS 12 MONTHS RECIRCULATION TANK WEEKLY FIELD DOSING TANK 3-6 MONTHS 12 MONTHS SUPPLY LINES, FORCE MAINS 6-12 MONTHS DISTRIBUTION FIELDS 2-4 WEEKS 3-6 MONTHS PUMPS, FILTER SYSTEM & DISTRIBUTION PIPING E-Z TREAT TREATMENT SYSTEM ULTRAVIOLET DISINFECTION UNIT MONTHLY ffl;ff3 CHECK FOR SOLIDS ACCUMULATION, BLOCKAGES, OR BAFFLE DAMAGE, IN/EXFILTRATION, PUMP SEPTAGE. CLEAN EFFLUENT FILTER. PUMP OUT ACCUMULATED SOLIDS IF NECESSARY. REPLACE EFFLUENT FILTER EACH TIME SEPTIC TANK IS PUMPED. CHECK PUMPS, CONTROLS, ALARMS, ELAPSED TIME METERS. CHECK FOR SOLIDS ACCUMULATION, IN/EXFILTRATION. PUMP OUT ACCUMULATED SOLIDS IF NECESSARY. CHECK FOR EXPOSED PIPE AND LEAKAGE. ILNPi'mmelaraIimlwom m12Wl»RNLI:IN21 CHECK FOR EROSION, OR PONDING OF EFFLUENT. CHECK FLOW METER READOUT AND COMPARE TO RECORDED FLOWS, CHECK PUMPS AND FILTER SYSTEM FOR LEAKS. QUARTERLY REMOVE FILTER COVERS AND INSPECT FOR ACCUMULATION OF DEBRIS. CHECK DIFFERENTIAL PRESSURE GAUGE BEFORE AND AFTER FLUSHING (D.P. SHOULD RETURN TO ORIGINAL OPERATING D.P.) CHECK PUMPS FOR ABNORMAL VIBRATION, TEST THE ALARM FUNCTIONS. SEMIANNUALLY REMOVE AND LUBRICATE 0-RINGS ON FILTER CANISTER, REPLACE IF DAMAGED, CLEAN 1-1/2" FILTER SCREEN AT HYDRAULIC UNIT. ANNUALLY REMOVE FILTER SCREEN AND REPLACE, CLEAN USED FILTER SCREEN IN MILD ACID SOLUTION AND STORE FOR NEXT ANNUAL REPLACEMENT, FLUSH FIELD SUPPLY AND RETURN MANIFOLDS BY REMOVING (UNSCREWING) AIR/VACUUM BREAKERS. MONTHLY INSPECT CONTROL/ALARM PANEL, PUMPING SYSTEM EFFLUENT FILTERS/PUMP SCREENS, RECIRCULATION TANK, AND E-Z TREAT POD FILTER. (TREATMENT UNIT) ANNUALLY CHECK AND/OR REPLACE BATTERIES IN FLOW METER. (IF APPLICABLE) 3-6 MONTHS WIPE (CLEAN) UV LAMPS. CHECK INTENSITY AND REPLACE LAMP WHEN REQUIRED. ANNUALLY CHANGE BULB. 4" SCH1140 PVC_ 1,000 GALLON - DWELLING - 11 SEPTIC TANK E-Z TREAT POD FILTER 1,000 GALLON E-Z TREAT RECIRCULATION41� TANK II II UV TREATMENT SYSTEM PLAN SCHEMATIC (i) NTS CP CP 4,500 GALLON FIELD DOSING TANK E-Z TREAT POD FILTER GROUND EL. t538.4' INV.EL. - DWELLING - ' — - - — . t536.5' GROUND EL. t538.4' F.F.E. t539.0' — �� _ (ASSUMED) 4" SCH. 40I PVC ® 2.00% MIN. INV. EL. — 1 t536.9' INV. EL. INV.EL. �YPA t539.4' 1 t536.7' t536.5' 0 INV.EL. ' (INV. OUT) 1,000 GALLON 1,000 GALLON±536.3t536.1 '��� SEPTIC TANK E-Z TREAT 4,500 GALLON FIELD RECIRCULATION TANK DOSING TANK NOTES: 4" SCH. 40 PVC - 4" SCH. 40 PVC 1. TANK LOCATIONS ARE NOT TO SCALE SO AS TO SHOW EACH TREATMENT ITEM. 2. ALL GRAVITY LINES SHALL BE 2% SLOPE MIN. 2;) TREATMENT SYSTEM PROFILE SCHEMATICNTS FORCE MAIN GROUND — GRAVITY LINE FLOW DIRECTION 10. THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE REUABLE, THE DESIGN PROFESSIONAL CANNOT ASSURE ITS ACCURACY, AND THUS IS NOT RESPONSIBLE FOR THE ACCURACY OF THIS RECORD DRAWING OR FOR ANY ERRORS OR OMMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO IT AS A RESULT. THOSE RELYING ON THIS RECORD DOCUMENT ARE ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE. RECORD DRAWING MAY 09, 2024 TO ZONE 1 ad W U U)Z J W a Lu Z Q Lu F- L) = =U cnZU ay Z z 00 I.- Lu W Z } a 0 z 0 W 0 a U) a } W = p U N. 0 aW U LL = p H U) ,y O O CD M I--co LUG N� co N Z J � Zza)ma% �O -aX W X U Q KL)� LL Mmm d ~ 0 z 04 D 0 LLF Q z J Q rn U U CD Ow H W� C� " 4 O CA OC ct 51201 GINS • G �. LEGEND J Z ADJACENT BOUNDARY JQ J C BOUNDARY (PROPERTY) d �v -_ --- 54-2-_ / III — — LLI LLI RIGHT-OF-WAY II CONTOURS - INDEX 0 64 I I I / I I CONTOURS -INTERMEDIATE Q DRAIN FIELD (SEPTIC) AREA --- �� _----- 100' RIPARIAN v �_------- _ II BUFFER �l TREELINE Z O `� ��38� .-- 1 O U) co $ I X PROPOSED FENCE X U Lo APPROX. LOCATION Lp CIA SUPPLY LINES W (� W Z �� �� -------------�3�----_ OF STREAM yy� I1 Y �\ SETBACKS < Z H -----v�---------_`�g� 5 11 s CO CLEAN OUT } � O ---/ \V CP CONTROL PANEL O IQ U ro -55T I \V 1 EZRT E-Z TREAT RECIRC. TANK otf U) Q �_--5_28 - } 1 } LU Z F —\ — — — — — I — — — — — o , 1 E-2 E-Z TREAT TREATMENT UNIT p V f. FDT FIELD DOSING TANK O LL W LL co��2 �� / III ° ST SEPTIC TANK y2 o ---- / / / 1 UV ULTRAVIOLET DISINFECTION U) — N � v I v . _x�� / Ix/V © PROPOSED WELL _-- --_ I - I I 1 II A A m C N ,— � _��2�� � I vv �� APPROX. vv NOTES: co.. Cc)N PROPOSED WELL Lo Li l cc / L'J 1. PARCELS AND TOPO TAKEN FROM NC (9 m O FRIS. z C) Q Q c 7 o / I © 2. CONVERSION OF TREATMENT ONLY. PERMITTED SPRAY IRRIGATION + -- r� c c I / ORIGINALLY DESIGNED BY DUANE K. ------------- j SITE (SEE NOTE 2)/ �� STEWART & ASSOCIATES, INC. AND n - �� / / / PERMITTED BY DEHNR MAY 31, 2005. H � w PROPOSED/ /� //� w // j 3. THIS IS NOT A SURVEY. U)co w Q/-� //� TREATMENT SYST / // (� �' 4. KEEP TANKS A MINIMUM OF 50' OFF W Z O / / �/ / / h / / OF PROPERTY LINES PER 15A NCAC Z - 04 .. 04 02T.0606(b). g X L) 23 `7a� / W Z LL PROPOSED DWELLING - 2'4 4 i�' / / Z L) m M Z M V �� I\ is SSECID 04 EERTY 1 �I II / O / / UPON INFORMATION THESE RECORD FURNISHED BY OTHERGS HAVE BEEN S PREPARED THIS Z CC A I 1 �CK j PROPOSED PORCH I PROPOSED (p / c„ / INFORMATION IS BELIEVED TO BE RELIABLE, THE DESIGN W O W C`' \ \ I ` UNDERGROUND �� - / �5' �°i PROFESSIONAL CANNOT ASSURE ITS ACCURACY, AND THUS IS Z J •./h � ca \ I ELECTRIC I ! v� �" NOT RESPONSIBLE FOR THE ACCURACY OF THIS RECORD a J 0 / // I I / b• . I / � / DRAWING OR FOR ANY ERRORS OR OMMISSIONS PMICH MAY L) E / M 1 / / ` I / / / / / HAVE BEEN INCORPORATED INTO IT AS A RESULT. THOSE U) W / �I I C�� I I ` CLEARED 1 / / / / RELYING ON THIS RECORD DOCUMENT ARE ADVISED TO OBTAIN Q Q Q% / / AREA INDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE L) L) 0 i / APPLYING IT FOR ANY PURPOSE. O O W I I RECORD DRAWING - � � �� a�-- ��� /� / i dim' -ao � // % PROPOSED / j j / o �� / PROPOSED DRIVEWAY' ^� � / TRANSFORMER /� MAY 09, 2024 � / GRAPHIC SCALE: 1 100' I GEQRGEHOPK/I�0' R/wPER R0 PB 0 100 200 40 300 P43 I--1 7 00 0 / / 0 g v co I —/— / _I__/ *�N � c\jN �0���� V A \ 45 �_ / / _ /_ � 0 FESS/ G V co ovy 51201 2 —INE�� v •: N / / - 1_1io" cru do Dvr LEGEND o ADJACENT BOUNDARY (q W D O BOUNDARY (PROPERTY) a �N 0 V RIGHT-OF-WAY 0 N CONTOURS - INDEX a CONTOURS - INTERMEDIATE DRAIN FIELD (SEPTIC) AREA z TREELINE 00 x PROPOSED FENCE ~Lu U SUPPLY LINES Y 2 � z } SETBACKS Q w O ~ a -v CO CLEAN OUT > } F- O O Q U CIDCONTROLCONTROL PANEL a EZRT E-Z TREAT RECIRC. TANK W w _ E-Z E-Z TREAT TREATMENT UNIT U N.W a' FDT FIELD DOSING TANK OU LL = Q ST SEPTIC TANK UV ULTRAVIOLET DISINFECTION © PROPOSED WELL m O N NOTES: m c N 1. PARCELS AND TOPO TAKEN FROM NC m co Lo H co FRIS. m 2 O Q QQ O 2. CONVERSION OF TREATMENT ONLY. ORIGINALLY DESIGNED BY DUANE K. i c CD STEWART & ASSOCIATES, INC. AND o PERMITTED BY DEHNR MAY 31, 2005. i n N T 3. THIS IS NOT A SURVEY. co 04 Z 4. KEEP TANKS A MINIMUM OF 50' OFF LLI Q JO OF PROPERTY LINES PER 15A NCAC z z rn M 02T.0606(b). g -1 04 Q x LuXUQ o LL THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED Z U m F UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, THE DESIGN 0 0 0 N PROFESSIONAL CANNOT ASSURE ITS ACCURACY, AND THUS IS z NOT RESPONSIBLE FOR THE ACCURACY OF THIS RECORD LU O a uj DRAWING OR FOR ANY ERRORS OR OMMISSIONS WHICH MAY 0 z J co HAVE BEEN INCORPORATED INTO IT AS A RESULT. THOSE Q J RELYING ON THIS RECORD DOCUMENT ARE ADVISED TO OBTAIN U } INDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE � y APPLYING IT FOR ANY PURPOSE. U U RECORD DRAWING - o W MAY 09, 2024 ~ U GRAPHIC SCALE: 1 " = 10' EL 0 5 10 20 30 Uj W � O " 0 G< o GFESS/ U 51201 GIN lb, S • G . E cm v 0 v N O N co c 75 (D m 0 O 0 o 00 00 in 0 0 C 0 U sz E cm 0 0 O E N 0 co 0 mi I 4" SCH. 40 PVC SEPTIC TANK FROM DWELLING 11 DETAIL 2, I D-104 DETAIL 1, D-101 E-Z TREAT POD FILTER IDETAII. 1, D-105 II I E-Z TREAT II RECIRCULATION TANK I IDETAIL 1, D-102 UV I I I I CONTROL PANELS CP CP ■ I FIELD DOSING TANK ( H I DETAIL 1, D-103 DETAIL 2, UV CAN BE PLACED INSIDE D-106 RECIRCULATION TANK RISER m TREATMENT SYSTEM DETAIL KEY C-105 NTS F- } w LEA wWY o a'a � wyw FORCE MAIN p GRAVITY LINE FLOW DIRECTION z z 00 � HU) � U w < w z NOTES: w z } 1. SEE DETAIL SHEETS FOR TANKS SIZES. d — z O W O a U) } p w U N. a = O aW U LL = H p U m O m N O N Lo c� m o F,ao m= Oa 0� THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, THE DESIGN PROFESSIONAL CANNOT ASSURE ITS ACCURACY, AND THUS IS NOT RESPONSIBLE FOR THE ACCURACY OF THIS RECORD DRAWING OR FOR ANY ERRORS OR OMMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO IT AS A RESULT. THOSE RELYING ON THIS RECORD DOCUMENT ARE ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE. RECORD DRAWING MAY 09, 2024 M O O O Lu Lu M ^ O � N � Q N Z Q J z?a,m°: 30-QX U w M X Q LL zUm�rn 0. z04 oOa_j z J Q Q cl) T o Ow V W� ,wu■nUp J N C A R p''•, O O �� °,, v ,.4, QFEssi QT ct �, 51201 Z:\T-Drive (Projects)\Library\2022\A08501.00 - Parker, Joy - 10311 Rougemount Rd., Durham - Spray Conversion\Drawings\A08501.00 - Base.dwg May 10, 2024 10:54am >Z�xozvZc� M'�A>�o"om �mzmzmvP—M zzOmoww>z'm T gZzf R?z2'MO m oWOOFD�N>o n AT'NA>'Dm OA Z'fA�IOZ'zr zD ;Clz�O��fD/l OfnN '0 o-omcoma O WO 0iwomWOA m ZpAAmA-<m N A~fD/li<DDilz nD O oowAm < o N Z S A Z W N NAo�mpNrm p3jzm mom �D�O=ON msCzusvm O o c < N zN =o`�� OTtic m 0 � C) D MacCONNELL & Associates, P Cl) m 0 0 Z D r M Cl) Q Z v 0 Z 0 D r 0 C r D 0 Cl) .m/ -7 Y Tl 77 7�:D p ;;J ;�J ;;J n 77 7 M r7 K O n I 71 77 n n n 0 n n D D r� D N N Z Z N N y N N Or C �- �r ;a;0--�7�J�7�JTJ��]?J nn�OZ -z 7D��1C�C)C�MD 71 71 � O r=Z��r DD -—yyr=r=r=�—�N�� cn �7Jz0� OO--D����O j 7J0Z)- 0n n p7JZz000r M Z Z Z� � D (n z C n z D 7J 0 n r-, D �D ---I 7a 0 � >>�u0F7 Cn �F7-fir;-_ 7Z IUIn Lr D 777 V) n00 :j�] r Q� y (A -� 7 Z D O r7 C7 g D C� Z F -1 '' O Z 7J Z 0 Z Cn D n n 77 C� 7J oo C G7 (/) 7-> -� r7 Z 75 71 Z) G� X p ��79 n r O D Z n z n z 7 77 c_r D n 0 > L n 0 ^ N 4, J CO Cis C i 7 CP cM C� C� r Z 0 D cc 00 Cr r n�n0KKKnn�� 0 �F7 >---D-CD Z >�r�ZZZ7-7-7-0 z n z F7 r" 1 M Z Z cn cn tn — L/)n cn LA \ �7 CD 7 7-r-� r 501 CASCADE POINTE LANE, SUITE 103 CARY, NORTH CAROLINA 27513 P.O. BOX 129 C. MORRISVILLE, NORTH CAROLINA 27560 TEL: (919) 467-1239 FAX: (919) 319-6510 D CA CA �l Cn c} z BY: CODY & JOY PARKER HGM, BAB JOB #: SURFACE SPRAY IRRIGATION A08501.00 WITH E-Z TREAT CONVERSION DATE: 08/31/2022 DURHAM COUNTY, NC DOSING CALCULATIONS C-106 F- CLEAN OUT SEPTIC FLOW FROM HOUSE -� / O I ` -c-!-t10' OF SCH 40 PVC 3/4" GATE VALVE (FIELDS ,ADJUST TO 4 GPM FOR E-Z TR SPIN FILTER RETURN FLOW) 1,000 GALLON SEPTIC TANK BY DAVID BRANTLEY & SONS LI ST-502 OR APPROVED EQUAL II EFFLUENT FILTER - FILTER SERVICE 24"0 E-Z SET RISER W/COVER I I HANDLE - IFF BELOW EDRIVEWAYRWISE OR PARKING) LOT THEN USE ONLY H-20 TRAFFIC RATED DEVICES 4" X 1-1/4' REDUCER 1" SCH 40 PVC RETURN FROM FIELD SEPTIC TANK (D-10)1NTS FLEX PVC INV. IN MIN. 18" BELOW LOWEST F.F.E. WITH WATER FIXTURE 1 z II - - - - - - - H L•h YL—L JGI RIJGR W/COVER (TYP. UNLESS OTHERWISE NOTED) �--� NOTE: FIELD VERIFY PRIOR TO ORDERING RISERS a e 00 •'� rD 3' _ ~ MIN. f 12" b FINISHED GRADE 1 (o 4" PVC �3/4" SCH. 40 PVC ECIRC. LINE A 4" SCH. D-101 40 PVC I \ - I I \ � I (SEE D-102 FOR CONTINUATION) WATER TIGHT SEAL ON RISER ASSEMBLY 3/4" SCH. 40 PVC RECIRCULATION LINE FROM E-Z TREAT TEE 4" SCH. 40 PVC _ (SEE D-102 FOR CONTINUATION) �INV. OUT 1"-2" BELOW INVERT IN SIMTECH STF 110 SERIES, POLYLOCK PL-68 OR INSTALLED WITH POLYLOK ENGINEERS APPROVED EQUAL PL-525 FILTER y. •_ 3„ TANK FLOOR MIN. a SEPTIC TANK SECTION D-101 NTS 1/3 TANK LENGTH NOTES 1. ALL PIPING SHALL BE SCH 40 PVC UNLESS J ti OTHERWISE NOTED ON PLANS. ALL PVC PIPES SHALL Q LLO BE BURIED A MINIMUM OF 3 FEET UNLESS SHOWN 0 OTHERWISE. LLI p p 2. ALL TANKS SHALL HAVE A MINIMUM 28-DAY CONCRETE STRENGTH OF 4500 PSI. 3. TANKS SHALL MEET REINFORCING REQUIREMENTS TO ACCOMMODATE 300 POUNDS PER SQUARE FOOT. EITHER STEEL REINFORCING WIRE, REBAR OR Z Z APPROVED FIBER MAY BE USED. O O 4. ALL SERVICE ACCESS OPENINGS WILL BE A MINIMUM a' a U OF 24 INCHES. EXCEPTIONS MAY BE MADE ON A Y Z CASE BY CASE BASIS WITH E-Z TREAT'S PRIOR ; WRITTEN APPROVAL. ALL ACCESS OPENINGS SHALL BE Z w H FITTED WITH E-Z SET RISER ASSEMBLIES. SERVICE d 0 Z =O ACCESS OPENINGS FOR THE RECIRCULATION CYLINDER } } SHALL BE A 30-INCH OPENING AND FITTED WITH AN O a U E-Z SET 30-INCH RISER ASSEMBLY. TRAFFIC RATED d Lu TANKS SHALL HAVE CONCRETE RISERS. 5. ALL JOINTS (TOP -SEAM) SHALL BE SEALED USING W N = CONCRETE SEALANTS BUTYL SEALANT # CS-102 O a W MEETING ASTM C-990. U LL = p ~ 6. TANKS SHALL BE LEAK -TESTED PRIOR TO SYSTEM START UP BY APPLYING A VACUUM OF 4-INCHES OF in MERCURY WITH RISER ASSEMBLIES IN PLACE OR WITH APPROVAL BY E-Z TREAT, A 24-HOUR STATIC WATER TEST, IN ACCORDANCE WITH ASTM STANDARDS. 7. NON -CONCRETE TANKS SHALL NOT BE USED IN O CONJUNCTION WITH THE E-Z TREAT SYSTEM WITHOUT m N PRIOR WRITTEN APPROVAL BY E-Z TREAT. 0 ..� W M 8. ALL PIPE PENETRATIONS THROUGH PRECAST 0 m 0 CONCRETE TANKS SHALL BE PRESS -SEAL m 2 O a D O CAST -A -SEAL 402 RUBBER BOOTS AND GROUTED. 9. THE FILTER POD INVERT OUT SHALL BE A MINIMUM iy CD CD OF 6" ABOVE THE INVERT IN OF THE RECIRCULATION c co TANK OR 1/4-INCH PER FOOT SLOPE, WHICHEVER IS Lu e7 Nco GREATER. 10. CONTRACTOR MAY USE LARGER TANKS. y 04LLF J Z 11. MAXIMUM COVER OVER NON H-20 TANKS SHALL BE z a, M - 30" OR AS SPECIFIED BY MANUFACTURER. J O C Q X U 12. SYSTEM INFLUENT SAMPLE SHOULD BE TAKEN FROM H Q XO 2 LL INLET TEE IN SEPTIC TANK RISER Z U co 13. SEE C-101 FOR GENERAL NOTES. m O z N `- Lu a 14. LENGTH, WIDTH, AND DEPTH OF TANKS WILL VARY 0 Z J m PER MANUFACTURER. U } J 15. MAY USE COMBINATION SEPTIC TANKS AND RECIRCULATION TANKS RATHER THAN SEPARATE IF U U NECESSARY OR DESIRED BY OWNER. J THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, THE DESIGN PROFESSIONAL CANNOT ASSURE ITS ACCURACY, AND THUS IS NOT RESPONSIBLE FOR THE ACCURACY OF THIS RECORD DRAWING OR FOR ANY ERRORS OR OMMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO IT AS A RESULT. THOSE RELYING ON THIS RECORD DOCUMENT ARE ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE. RECORD DRAWING MAY 09, 2024 H I� I� '^ W �VI " , N A R ' .,� O o CA 0 e� � ssi oFE QT - �- 51201 GINE�� G B P� �• E cm v 0 v N O N 0 m 75 ro 0 C==== TO E-Z (SEE NUATI FOR 1-1/2" SCH. 40 PVC TREAT POD CONTINUATION) F--- I 30"0 E-Z SET RISERI- W/COVER (TYP) ------ f3/4" SCH. 40 PVC RECIRC. LINE TO SEPTIC --------------------------------------------- -------------------------------- ------------------- CLEAN OUT (SEE D-101 FOR O CONTINUATION) FLOW —► PRECAST CONCREr "DONUT" (OPTION) (TYI 12" MIN. LENGTH FLEX PVC 1,000 GALLON RECIRCULATION/PUMP TANK BY DAVID BRANTLEY & SONS PT-237 OR APPROVED EQUAL TURBINE PUMP TEE L---------------------� 1 RECIRCULATION TANK D-102 NTS CAST -A -SEAL 402 RUBBER BOOT (TYP.) 4" SCH. 40 PVC DROP TEE (TYP.) i--� 3/4" SCH. 40 PVC RECIRC. LINE 30"0 E-Z SET RISER W/COVER (TYP) 3/4" BALL VALVE 3/4" UNION FROM E-Z TREAT POD II , 00orr TO FIELD DOSING D CHAMBER J ti N QLL O L j � p p EFFLUENT BYPASS VALVE W/FLOW REFTRICTOR TO 10 GPM I a D-102 L_ f mutt FLOAT TI BRAC 4" X 2" REDUCER (2) UV UNIT (TYP.) 4" X 2" REDUCER I ALARM LIGHT CONTROL PANEL (LOCATED H WITHIN 10-FEET OF TANKS) DIRECT BURY CABLE TO PANEL 1-1/2" PVC CHECK VALVE 1-1/2" SCH. 40 PVC FULL UNION (TYP.) HIGH WATER ALARM= — - 40" ABOVE FLOOR � ,�, 1-1/2" SCH. 40 PVC LINE TO FILTER POD 7 NOTE: UV UNIT NOT SHOWN FOR CLARITY. SEE DETAIL 2, D-107 a I I N EFFLUENT BYPASS DOSE ENABLE_=VALVE BY E-Z TREAT 22" ABOVE FLOOR �� I I SEE EFFLUENT BYPASS VALVE SECTION A, D-104 o PUMP OFF= _ 3/1 C ANTI -SIPHON * 18" ABOVE FLOOR HOLE (TYP) MERCURY FLOAT +I 1-1/2" SCH. 40 ( SWITCHES (3) PVC FLOAT TREE 3' I� ALL TANKS REQUIRE A STA-RITE MULTI -STAGE 57 STONE SUBMERSBLE PUMP PART 3" PVC STAND 8" THICK # NUMBER STEP 30 1/2 HP BEDDING (TYP.) OR EQUAL PER E-Z TREAT a RECIRCULATION TANK SECTION D-102 NTS (SEE D-105 FOR CONTINUATION) THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, THE DESIGN PROFESSIONAL CANNOT ASSURE ITS ACCURACY, AND THUS IS NOT RESPONSIBLE FOR THE ACCURACY OF THIS RECORD DRAWING OR FOR ANY ERRORS OR OMMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO IT AS A RESULT. THOSE RELYING ON THIS RECORD DOCUMENT ARE ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE. RECORD DRAWING MAY 09, 2024 Z z 00 HU) < Lu Luz } d 0 z 0 0 a IQ U) a } Lu = p U N. O aW U LL = p H U m O N O m � N (7 co Lu m O H co m= Oa o� iy O O 0 M n Lu N O U) N Z J T Z z rn = _jO -aX x Lu < LL LL Zuco rn a~Oz04 DOa�m Q z J Q < rn U U CD Ow H W� ���uunUp O 0 � CAR p •'•, CA �- 51201 '. INE E cm v 0 v N O N O co 75 0 0 0 o 00 00 Q in 0 0 0 c O U m Q E cm 0 rr 0 E ro 0 !r co 0 0 0 15 cm a O O 0 Lo 00 O N N O N c� U m O L (D — — — — — — — — — — — — — — — — — — — — — — — — — — — I I 1 I + I \ I I � / I — TURBINE 4,500 GALLON PUMP TANK BY DAVID BRANTLEY & SONS PT-H2O-506 OR APPROVED EQUAL 1 FIELD DOSING TANK PLAN D-103 NTS z (SEE D-102 FOR CONTINUATION) 6„ MIN. 04 X I \ FLOAT TREE (TYP.) 1-1/2" SCH. 40 PVC FULL UNION SWITCHES (4) 1-1/2" SCH. 40L_",--- 1 PVC FLOAT TREE rr EFFLUENT PUMP AS ORIGINALLY - DESIGNED BY DUANE K. STEWART & ASSOCIATES, INC., OR EQUAL a FIELD DOSING TANK SECTION D-103 NTS A 06, D-103 I TO HYDRAULIC UNIT I 1-1/2" PVC CHECK VALVE / DIRECT BURY f/ CABLE TO PANEL 1-1/4" SCH. 40 PVC TO HYDRAULIC UNIT - PUMP SCREEN BY SIM-TECH O/E 6. MIN 3" PVC STAND PRECAST CONCRETE "DONUT" (OPTIONAL) NOTE: 1. PIPING TO BE 4" SCH. 40 PVC 2 GRAVITY CLEANOUT D-103 NTS MINI -CLICK RAIN SENSOR r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co J ti M aU LU o a Z z 00 H U) � � U W < W Z } d 0 z 0 W O a U) a } W = p U N. O a W U LL = p H U m O N O m � N (7 co Lu m O H ao m= Oa o� iy O O 0 Lu M n W � N � co N Z J Z z rn = _jO -aX U W < X Q ZL)LL Do a~0z04 D 0 LLT Z Q J Q U rn U U CD OW 2H W� ct " ���uunUp O O ..`°.� N C A R p •'•, CA lass ess QT 51201 , '• INE�� .: C. P�Ge`�,, EFFLUENT BYPASS VALVE BY E-Z TREAT'1>nllvi FINISHED GRADE 4" FROM FILTER POD 4" SCH. 40 PVC FLOW CONTROL CROSS (TYP.) WEIR \-WATER LEVEL PLATE '' 4" SCH. 40 PVC (FIELD ADJUST TO SHUT- OFF RETURN FLOW TO FLOAT BALL - RECIRCULATION TANK AT 6" BELOW SECONDARY TIMER ELEVATION) s' I to MIN. a EFFLUENT BYPASS VALVE SECTION D-104 NTS 1-1/2"x1-1/2"0/4" PVC REDUCING TEE 3/4" SCH. 40 PVC RECIRC LINE FIN. GRADE iIi 30"0 RISER W/COVER SEE GEN. NOTES 1-1/2" ELBOW (TYP.) 1-1/2" SCH. 40 PVC FULL UNION .. (TYP.) U 1-1/2"" PVC CHECK 3/4" PVC VALVE GATE VALVE 1-1/2" 3/4" SCH. 40 PVC LINE TO FROM UNION FILTER POD (TREATMENT POD) PUMP 3/4" 90' ELBOW B RECIRCULATION TEE SECTION D-104 NTS 1 4" 90' BEND �4"TO ULTRAVIOLET DISINFECTION UNIT (IF APPLICABLE) OR FIELD DOSING TANK ALL TANKS REQUIRE A 6" THICK STONE BASE (TYP.) 1455Le City, I 4971 � J/ T_lE �� Eema le sak Ea.: 62 58�2 4 Boyae City, INI 49712 J 1 �� _ Office: 231-582,1020 E Toll Free: 988-999-3290 Sim/Tech Filter Adds to it's Pump Protector Line 15 x 48 Pump Screen Main Features • 1/8" perforated polypropylene • Built in Float Tree Bracket • "J" Hook Wire Organizer • High Strength construction • Unit weighs less than 16 pounds Float Tree Bracket accepts 1-1l4 "J" Hook pv��,,✓. �� anizer A F Part# STF-1548P125 Also, available in other sixes Base excepts concrete for extra weight • 2" raised bottom • 13-1/2" Inside Diameter 15-1/2" Outside Diameter • 48" overall height Over 850 sunare inches of t vs" Perforations • Over 69,000 1/8" round holes 1 PUMP SCREEN D-104 NTS co J I- LL o LU o p ZZ 00 H � Y � z } a X0 z } 0 W 0 a U) a } W = a UN XX O aW U LL = p H m O N m � O N to C9 m c H ao m= Oa o� ty o 0 o CO "I" M n LUG N� Z C0 NLd J � ZZa��a% �O—aX UL LU<XULL zUm� �rn a�OzC14 o0aLu _jCO J� Uz to rn Q U U " THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED CD Lu UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, THE DESIGN 0 H PROFESSIONAL CANNOT ASSURE ITS ACCURACY, AND THUS IS NOT RESPONSIBLE FOR THE ACCURACY OF THIS RECORD DRAWING OR FOR ANY ERRORS OR OMMISSIONS WHICH MAY V HAVE BEEN INCORPORATED INTO IT AS A RESULT. THOSE RELYING ON THIS RECORD DOCUMENT ARE ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE. \ ' RECORD DRAWING MAY 09, 2024 W s�tuunUp O 0 0 oFESS, QT C� y 51201 '• INE�� .: •�'•.....:7Z,a�/zap 2" X 6" BOARD WITH ALUMINUM BRACKETS ATTACHED TO POD WITH 7'-3-1/2" (TYP) S.S. SCREWS TO ASSIST - SOIL STABILIZATIONH (TYP. OIF4) — 4" CPP (SEE SITE PLAN FOR OUTLET) o - 3/4" CAP o 0 o ° (TYP.) o o I o o TO OUTLET o SPRAY NOZZLE ° o o (TYP.) o o � o o PRESSURE GAUGE I 1-1/2" BALL VALVE o D-105 o I o 4" SCH. 40 PVC 90- ELBOW (TYP.) NOTES: 1. PROVIDE UNDERDRAIN ON SITES WHERE SEASONAL HIGH GROUNDWATER IS WITHIN 6" OR ABOVE THE BOTTOM OF THE TANKS. 1 E-Z TREAT TREATMENT UNIT PLAN D-105 NTS TOP OF POD -Z TREAT POD FILTER SYSTEM 12" rMIN- 1-1/2"0 SUPPLY LINE 4"0 RETI LINE iu 4" CPP 6" THICK #57 PERFORATED STONE BEDDING TUBING (SLOTTED) (TYP.) SEE SHEET AROUND POD C-102 FOR (TYP.) INVERT OUT q E-Z TREAT TREATMENT UNIT SECTION D-105 NTS 3' ALL AROUND_ SELECT BACKFILL FREE OF DEBRIS FINISHED GRADE `31 THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, THE DESIGN PROFESSIONAL CANNOT ASSURE ITS ACCURACY, AND THUS IS NOT RESPONSIBLE FOR THE ACCURACY OF THIS RECORD DRAWING OR FOR ANY ERRORS OR OMMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO IT AS A RESULT. THOSE RELYING ON THIS RECORD DOCUMENT ARE ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE. RECORD DRAWING MAY 09, 2024 co ti Lo au L wo a Z z 00 H W W z } d 0 z 0 IQ 0 a U) a } W = p U N. O a W U LL = p H U m O N m O N co Lu 0 m O t- co m= Oa 00 iy O O Lu M I.- w W - N T Z cl) 04ULT J T Z z rn = �O-QX U W < X Q ZL)LL co a~Oz04 DOaWm Q z J � rn Q U U Q Ow F- W � ���uunUp O 0 p•'•, V1 QT c y 51201 , '. INE�� C. P�GP,�. E co v 0 v N 0 N 0 m 75 m 0 TWO (2) #4 REBAR ---. 1 I 1 TOP VIEW z M v I NOTE 5 SIDE VIEW NOTES: 1. PROVIDE TANK BALLAST ON SITES WHERE SEASONAL HIGH GROUNDWATER IS WITHIN 6" OR ABOVE THE BOTTOM OF THE TANKS. 2. CABLES SHALL BE 3/16" STAINLESS STEEL, LENGTH VARIES PER TANK. 3. CONNECT CABLE TO REBAR EMBEDDED IN BALLAST WITH TWO (2) STAINLESS STEEL CLAMPS PER CONNECTION. 4. TIGHTEN MINIMUM 2 CABLES PER TANK. 5. EACH CABLE SHALL BE A MINIMUM OF 2' FROM END OF TANK. 6. REBAR SHALL BE NO. 4. 7. BALLAST MAY BE PRECAST OR POURED IN PLACE USING PLYWOOD FORMS. 8. TOTAL SEPTIC TANK BALLAST SHALL BE A MINIMUM OF TWO (2) CUBIC YARDS. 9. TOTAL RECIRCULATION/FIELD DOSING TANK BALLAST SHALL BE A MINIMUM OF TWO (2) CUBIC YARDS. 10. CONCRETE SHALL BE A MINIMUM OF 3,000 PSI. 11. CONTRACTOR MAY USE CONCRETE WHEEL STOPS WITH MINIMUM CONCRETE MASS PROVIDED WITH APPROVAL OF ENGINEER. 12. SEE BUOYANCY CALCULATIONS IN APPLICATION PACKAGE FOR BALLAST DIMENSIONS. NOTE 1 NOTE 2 °l�3 1 TANK BALLAST DETAIL (OPTIONAL) D-106NTS 1007 4" WELL CAP BACKUP DISCONNECT PRIMARY LAMP LAMP UNION (TYP.) 4" 2" 2" 4 CONTROL 101 � WITH ALARM 4 x2" REDUCER REDUCER VALVE BALL 2"x2"x1/2" — TOP VIEW VALVE REDUCING TEE NOTES: 1. ULTRAVIOLET LIGHT PURIFIER 4" 2„ — — 2" 4" UV-102 BY E-Z TREAT. 2. PROVIDE DUAL GFI RECEPTACLE ly FOR UNIT AND HEAT TAPE. FIELD 4" x 2" ROUTE 2-#12,1-#12G, IN 3/4" REDUCER 1/2" BALLQ\"-4" x 2" PVC CONDUIT TO 120 VOLT VALVE REDUCER SINGLE PHASE 20 AMP BREAKER AT HOUSE. DISCONNECT 3. ORIENTATION PER SITE UNION (TYP.) REQUIREMENTS. PRIMARY 100% LAMP -� _ BACKUP 4. INSTALL 1/2" BALL VALVE FOR LAMP SAMPLING DOWNSTREAM OF U.V. UNIT. 5. MAY LOCATE IN RECIRCULATION TANK IF ACCESS PROVIDED. NON -CORROSIVE REFLECTIVE AND ACTION VI©Q( PROTECTIVE SLEEVE 2 ULTRAVIOLET DISINFECTION D-106 NTS THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, THE DESIGN PROFESSIONAL CANNOT ASSURE ITS ACCURACY, AND THUS IS NOT RESPONSIBLE FOR THE ACCURACY OF THIS RECORD DRAWING OR FOR ANY ERRORS OR OMMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO IT AS A RESULT. THOSE RELYING ON THIS RECORD DOCUMENT ARE ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE. RECORD DRAWING MAY 09, 2024 co J ti co aU LU o a Z z 00 H U) UJ < Luz } d 0 z 0 IQ 0 a U) a } Lu = p U N. O aW U LL = p H U iy CD CD CD c M ^ c D LUG N� co N Z J � Z z 0)M = a �O - X Lu < LL x LL ZL)co d z 04 0 0 Lu Q z J Q � rn U U IX CD OW �2H V W� ct 0 0 V CA CA E Co v O v N O N O Cti 75 a� 7 N G) 0 0 `m 15 Co a O O 0 LO 00 O N N O N Co U a Branch Circuit Protection Device/Disconnect Means Field Provided - PUMP size per manufacturing specifications for pump/motor Incoming Power 120/230 VAC, 50/60HZ PUMP LOAD G L1 L2/N 120/230 VAC, 0-16 AMPS, 50/60 HZ I T3 PUMPS MUST CONTAIN INTEGRAL THERMAL OVERLOAD PROTECTION! GL I - IYI � l T, 71 PUMP1 20A M1 0 GROUND TO GROUND LUG CONTROL Incoming Power 120 VAC, 50/60HZ L1 N I I CB2t, 1OA D F2 F1 II II FS2 - Timer Enable TB3 TB 1 �d �G1 HAND SW1 1 ACR1TD1A e1��14 1a AUTO FS3 - High Alam, TB5 TB6At A2 FS1 - Low AIamI "a —Ia, TB2 n1_ Az ALARM BEACON -®_ 21 12 z SW2 -R314 Al R A2 Testa Silence F1, F2 FUSE MUST BE DREPLACED WITH 1 AMP 5mmX20mm TYPE FAST ACTING 250 V MAX. This control panel is for timed dosing applications. When the timer enable float is up, the timer will start timing for the duration of the "Off' time and when complete, the pump will start for the duration of the "On" time. Both Off and On times are adjustable. This pattern repeats until the timer enable float lowers and turns off. The Low float acts as a redundant off and will also activate the alarm. If the level reaches the High float switch, the alarm will activate. TB1 TB2 TB3 TB4 TB5 TBa S3--High FBI - Low FS2W- 3 Level Level Timer Enable Float Switch Field Wiring *FS1 - Normally Open, Narrow Angle *FS2 - Normally Open, Wide Angle *FS3 - Normally Open, Narrow Angle --- FIELD WIRING FIELD SUPPLIED ® TERMINAL BLOCK TB Paver Wiring = BLK 120VAC Control Wiring = RED Neuhal = WHT Ground = GRN TIGHTENING AWO OR TORQUE IN INCH CIRCULAR MILLSRE SCRE, EXTERNAL Dwwa WREMNIN CH 14 3s s 12 3s s 10 ss s s ao Ts S Ce 11a A 2 so ,so so ,so vo so Teo 2m so eo LEGEND OR, CONTROL RELAY CB CIRCUIT WEIXER GL GROUND LUG SW1 HOA S`MMH slN2 TEST/SILENCE SwROI R ALARM BEI B ALARM BMER MI MAGNETIC CONTACTOR G1 PUMP RUN INDICATOR GL GROUND UIG FS FLCAT SlVRO1 TD1 RWy Cytl Timer Off Hrs On o 0 6 B Off 1 12 Scale (M(�in ® R- On "n To set the timer, use a screwdriver to change timer Scale (0-12 most common). Use a screwdriver to change the "On" time increments (minutes most common). Use a screwdriver to change the "off' time increments (hours most common). Turn the dial with the Red line to the desired "On" time (this example is 2 minutes). Turn the dial with the Green line to the desired "Off' time (this example is 4 Hours). Notes: 1. WARNINGI Electrical Shock Hazardl Disconnect power before servicing this product. A qualified service person must install and service this product according to applicable electrical and plumbing codes. 2. Install in accordance with National Electric Code, NFPA 70, Seal all boxes, fittings and conduit with appropriate seal devices to prevent moisture and gases from entering enclosure. 3. Connect all grounds to a good ground. 4. Dashed lines represent field wiring - Use minimum 60 deg C Copper Wire 5. Branch Circuit Protection Device/Disconnecl Means Field Provided. E-Z TREAT COMBO SIMPLEX CONTROL PANEL D-107 NTS NOTES: � tiLL ti 1. PANEL BY ALDERON, OR EQUAL. 0 O 2. PANEL TO BE SUPPLIED BY E—Z TREAT. LU ti 3. CONTRACTOR MAY USE COMBINED E—Z TREAT / UV PANEL. Z Z Terminal Connections 02 C a U CONTROL PUMP PUMP W W Z Incoming Power Incoming Power Connection 0 120 VAC, 50/60HZ 120/230 VAC, 50/60HZ Z } L1 N L1 L2RJ a 0 � z I I U } TB1 TB2 TB3 TB4 TB5 TB6 Q Q Q Q 4 4 [] [h 6 6 T1 T2 Q Q } 0 � a 0 06 a W < b�LU FS3 - Vzz F51 -Low FS2-Le el Level Timer Enable A 0 �% N. a W Float Switch Field Wiring U LL *FSS - Normally Open, Narrow Angle O — *FS2 - Normally Open, Wide Angle U) *FS3 - Normally Open, Narrow Angle ELECTRICAL SPECIFICATIONS 1. TWO DIFFERENT CONTROL PANELS WILL CONTROL THE WASTEWATER SYSTEM. ONE CONTROLS THE PRETREATMENT AND ONE CONTROLS THE ULTRAVIOLET DISINFECTION. CONTRACTOR MAY USE A COMBINED PANEL. 2. EACH PANEL SHALL BE APPROXIMATELY 13" WIDE X 15" HIGH AND IS A NEMA 4X, UL RATED ENCLOSURE. THE PANELS SHALL BE SUPPLIED BY THE SYSTEM DISTRIBUTOR. 3. THE PANELS SHALL BE MOUNTED BY THE ELECTRICIAN WITHIN 10' OF THE TANK UNITS. THEY SHALL BE MOUNTED NEXT TO EACH OTHER AND 48" — 60" OFF THE FINISHED GRADE TO THE BOTTOM OF THE ENCLOSURE. 4. THE BUILDER'S ELECTRICIAN SHALL MAKE THE INTERNAL PANEL CONNECTIONS OF THE PUMP AND CONTROL CORDS. EACH CONTROL PANEL SHALL CONTAIN A WIRING SCHEMATIC IDENTIFYING ALL TERMINAL CONNECTIONS. THE SYSTEM INSTALLER SHALL BUNDLE AND MARK EACH CORD WITH THE APPROPRIATE IDENTIFICATION AND SECURE IN THE ACCESS RISER AT THE DIFFERENT PUMP POINTS. 5. THE PRETREATMENT CONTROL PANEL REQUIRES A DEDICATED CIRCUIT OF 20 AMPS, 230 OR 115 VOLTS, SINGLE PHASE SUPPLIED FOR THE PUMP. 6. THE PRETREATMENT CONTROL PANEL REQUIRES A DEDICATED CIRCUIT OF 15 AMPS, 115 VOLTS SUPPLIED FOR THE ALARM / CONTROL SIDE OF THE PANEL. 7. THE PRETREATMENT CONTROL PANEL REQUIRES A TELEPHONE EXTENSION LINE FROM THE DWELLING FOR THE RMSYS TELEMETRY SYSTEM. THIS IS NOT A DEDICATED LINE; IT IS AN EXTENSION FROM ANY LINE THAT IS USED IN THE DWELLING. 8. A MINIMUM CONDUIT SIZE OF 1 1%" SHALL BE FURNISHED AND INSTALLED BE THE ELECTRICIAN AS A CONNECTION BETWEEN EACH CONTROL PANEL AND THEIR RESPECTIVE TERMINATION POINTS OUT IN THE TANK AREA. 9. ALL OPEN CONDUIT ENDS SHALL HAVE REMOVABLE CLAY TYPE DUCT SEAL EMBEDDED TO PREVENT GASES AND MOISTURE FROM ENTERING THE CONTROL PANELS. DO NOT USE PERMANENT SILICONE OR EXPANDABLE FOAM PRODUCTS. 10. ALL PUMP AND FLOAT CONTROL CORDS SHALL BE SUPPLIED WITH EITHER 30' OR 50' LEADS. THIS WILL HELP KEEP SPLICES TO A MINIMUM AND SHOULD BE AVOIDED IF AT ALL POSSIBLE. IF A SPLICE MUST BE USED, IT MUST BE MADE ABOVE GRADE IN A PLASTIC NEMA 4X JUNCTION BOX. 11. ALARMS SHALL BE AUDIBLE AND VISUAL. ALARMS SHALL ACTIVATE AUTO DIALER TO RMSYS SYSTEM. 12. AUDIBLE/VISIBLE ALARMS SHALL BE EXTERNAL TO ANY STRUCTURE. 13.PROVIDE MANUAL TRANSFER SWITCH AND PLUG FOR PORTABLE EMERGENCY GENERATOR. PROVIDE DISCONNECT PER NCBC AND NEC. THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, THE DESIGN PROFESSIONAL CANNOT ASSURE ITS ACCURACY, AND THUS IS NOT RESPONSIBLE FOR THE ACCURACY OF THIS RECORD DRAWING OR FOR ANY ERRORS OR OMMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO IT AS A RESULT. THOSE RELYING ON THIS RECORD DOCUMENT ARE ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE. RECORD DRAWING MAY 09, 2024 0 OF�SS� � 51201 i • NGINE�� Pv�•` �O C. B '101011111111% / ty O O O L M cm W � N T 040 CD Z J T Zz0)M �O�aX W X U Q LL zL)ED d 0 Z 04 DaWOm Q z J CO� U L) O OW 2H W� O\ 6 V