HomeMy WebLinkAboutNC0079821_Staff Report_19930120cc: Permits and Engineering /Technical Support Branch County Health Dept. Central Files WSRO SOC PRIORITY PROJECT: Yes _ No X If Yes, SOC No. To: Permits and Engineering Unit Water Quality Section Attention: (Susan Robson) Date: January 20, 1993 NPDES STAFF REPORT AND RECOMMENDATION County Forsyth Permit No. NCO079821 03 -0'1 - 04 S R l,t �Ieee u— PART I - GENERAL INFORMATION 1. Facility and Address: R. A. Thomas Water Filtration Plant 1201 Martin Luther King, Jr. Drive Winston-Salem, NC 2. Date of Investigation: January 15, 1993 3. Report Prepared by: Lee G. Spencer 4. Persons Contacted and Telephone Number: Ron Hargrove & Ed Davis 727-8418 784-7597 5. Directions to Site: From WSRO, take US 52 South to Stadium Dr. exit. Turn left at light and go to MLKJr Dr. Turn right onto MLKJr Dr. and proceed to Water Filtration Plant on your left just beyond intersection with Reynolds Park Rd. 6. Discharge Points(s), List for all discharge points: Latitude: 36004'15" Longitude: 80°13'00" U.S.G.S. Quad No. C18-SW U.S.G.S. Quad Name W-S East 7. Site size and expansion area consistent with application 7 X Yes No If No, explain: 8. Topography (relationship to flood plain included): Gently rolling terrain. Lagoons not subject to flooding. 9. Location of nearest dwelling: `2000' ;t vq 3- "I 10. Receiving stream or affected surface waters: Salem Creek a. Classification: C b. River Basin and Subbasin No.: 03-07-04 C. Describe receiving stream features and pertinent downstream uses: Stream flows through very urban areas on its way toward Yadkin River. Part II - DESCRIPTION OF DISCHARGE AND TREATMENT WORKS 1. a. Volume of Wastewater to be permitted: N/A (Ultimate Design Capacity) b. What is the current permitted capacity of the Waste Water Treatment facility? No flow limit C. Actual treatment capacity of the current facility (current design capacity)? N/A (Water Trmt. Plant capacity is 27 MGD) d. Date(s) and construction activities allowed by previous Authorizations to Construct issued in the previous two years. e. Please provide a description of existing or substantially constructed wastewater treatment facilities: Filter backwash water and clarifier underdrains are pumped to either of two 1.8 MG lagoons which are in parallel. Influent enters on one side of each lagoon and exits on the other side via surface skimmers. Effluent is then pumped to drainage canal which flows into Salem Creek. f. Please provide a description of proposed wastewater treatment facilities. N/A g. Possible toxic impacts to surface waters: Only possibility would be chlorine residual impact, which should be minimal. h. Pretreatment Program (POTWs only): in development approved should be required not needed 2. Residuals handling and utilization/disposal scheme: a. If residuals are being land applied, please specify DEM Permit No. NPDES Permit Staff Report Version 10/92 Page 2 Residuals Contractor Telephone No. b. Residuals stabilization: PSRP PFRP Other co Landfill: d. Other disposal/utilization scheme (Specify): Each lagoon is drained and cleaned approximately one time per year. Heavy equipment is used to remove "alum type" sludge off the bottom and it is spread onto a large, level field which is immediately adjacent to the lagoons. 3. Treatment plant classification (attach completed rating sheet): Class I 4. SIC Code(s): 4941 Primary 21 Secondary Main Treatment Unit Code: 3 0 0 _ 3 PART III - OTHER PERTINENT INFORMATION 1. Is this facility being constructed with Construction Grant Funds or are any public monies involved. (municipals only)? 2. Special monitoring or limitations (including toxicity) requests: None 3. Important SOC, JOC or Compliance Schedule dates: (Please indicate) Date Submission of Plans and Specifications Begin Construction Complete Construction 4. Alternative Analysis Evaluation: Has the facility evaluated all of the non -discharge options available. Please provide regional perspective for each option evaluated. Spray Irrigation: Impractical Connection to Regional Sewer System: Impractical Subsurface: N/A NPDES Permit Staff Report Version 10/92 Page 3 Other disposal options: 5. Other Special Items: PART IV - EVALUATION AND RECOMMENDATIONS This office has no objection to the issuance of this permit. The facility appears well operated and maintained. t ignature of report preparer ,.1- J Water Quality Region'l Supervisor NPDES Permit Staff Report Version 10/92 /-Z-a- "F3 Date Date Page 4