HomeMy WebLinkAboutWQ0045345_Application (FTSE)_20240429a RECEIVED/NCDENR/DWR State of North Carolina DWR APR 2 9 2ppartment of Environmental Quality UL Division of Water Resources FA T TR)9OKSM%ER SYSTEM EXTENSION APPLICATION Division of Water Resources INSTRUCTIONS FO X , r�0[�Iig4 SUPPORTING DOCUMENTATION r5 egiona Office This application is for sewer extensions involving gravity sewers, pump stations and force mains, or any combination that has been certified by a professional engineer and the applicant that the project meets the requirements of 15A NCAC 02T and the Division's Minimum Design Criteria (Gravity Sewer & Pumo Stations/Force Mains l and that plans, specifications and supporting documents have been prepared in accordance with 15A NCAC 02T. 15A NCAC 02T .0300, Division policies, and good engineering practices. While no upfront engineering design documents are required for submittal, in accordance with 15A NCAC 02T .0305(b), design documents must be prepared prior to submittal of a fast track permit application to the Division. This would include plans, design calculations, and project specifications referenced in 15A NCAC 02T .0305 and the applicable minimum design criteria. These documents shall be immediately available upon request by the Division. Projects that are deemed permitted (do not require a permit from the Division) are explained in 15A NCAC 02T.0303. Projects not eligible for review via the fast track process (must be submitted for full technical review): ➢ Projects that do not meet any part of the minimum design criteria (MDC) documents; ➢ Projects that involve more than one variance from the requirements of 15A NCAC 02T; ➢ Pressure sewer systems utilizing simplex septic tank -effluent pumps (STEPS) or simplex grinder pumps; ➢ Simplex STEP or simplex grinder pumps connecting to pressurized systems (e.g. force mains); ➢ Vacuum sewer systems. General — When submitting an application, please use the following instructions as a checklist in order to ensure all required items are submitted. Adherence to these instructions and checking the provided boxes will help produce a quicker review time and reduce the amount of requested additional information. Failure to submit all required items will necessitate additional processing and review time, and may result in return of the application. Unless otherwise noted, the Applicant shall submit one original and one copy of the application and supporting documentation. A. One Original and One Copy (second copy may be digital) of Application and Supporting Documents ® Required unless otherwise noted. Signatures on original must be "wet ink" or secure digital signatures. Please do not submit engineering design plans with the application unless specifically requested. B. Cover Letter/Narrative Description (Required for All Application Packages): ® List all items included in the application package, as well as a brief description of the requested permitting action. ➢ Be specific as to the system type, number of homes served, flow allocation required, etc. ➢ Include the permit number/status of any other required sewer permits (downstream/upstream) ➢ If necessary for clarity, include attachments to the application form. C. Application Fee (Ali New and Modification Application Packages): ® Submit a check or money order in the amount of $600.00, dated no more than 90 days prior to application submittal. ➢ Payable to North Carolina Department of Environmental Quality (NCDEQ) D. Fast Track Application (Required for All Application Packages, Form FTA 05-21): ® Submit the completed and appropriately executed application. ➢ If necessary for clarity or due to space restrictions, attachments to the application may be made. ❑ If the Applicant Type in Item I.2 is a corporation or company, provide documentation it is registered for business with the North Carolina Secretary of State. ❑ If the Applicant Type in Item I.2 is a partnership or d/b/a, enclose a copy of the certificate filed with the Register of Deeds in the county of business. ® The Project Name in Item II.1 shall be consistent with the project name on the flow acceptance letters, agreements, etc. ® The Professional Engineer's Certification on Page 5 of the application shall be signed, sealed and dated by a North Carolina licensed Professional Engineer. ® The Applicant's Certification on Page 5 of the application shall be signed in accordance with 15A NCAC 02T .0106(b). Per 15A NCAC 02T .0106(c), an alternate person may be designated as the signing official if a delegation letter is provided from a person who meets the criteria in 15A NCAC 02T .0106(b). INSTRUCTIONS FOR FORM: FTA 06-21 & SUPPORTING DOCUMENTATION Pagel of 3 E. Flow Tracking/Acceptance Form (Form: FTSE 04-16) (If Applicable): ® Submit the completed and executed FTSE form from the owners of the downstream sewers and treatment facility. ➢ Multiple forms maybe required where the downstream sewer owner and wastewater treatment facility are different. ➢ The flow acceptance indicated in form FTSE must not expire prior to permit issuance and must be dated less than one year prior to the application date. ➢ Submittal of this application and form FTSE indicates that owner has adequate capacity and will not violate G.S. 143-215.67(a). ➢ Intergovernmental agreements or other contracts will not be accepted in lieu of a project -specific FTSE. F. Site Maps (All Application Packages): ® Submit an 8.5-inch x 11-inch color copy of a USGS Topographic Map of sufficient scale to identify the entire project area, including the closest surface waters. ➢ General location of the project components (gravity sewer, pump stations, & force main) ➢ Downstream connection points and permit number (if known) for the receiving sewer ® Include an aerial location map showing general project area (such as street names or latitude/longitude) so that Division staff can easily locate it in the field. G. Existing Permit (Application Packages for Modifications to an Existing Permit): ® Submit a copy of the most recently issued existing permit. ® Include a descriptive and clear narrative identifying the previously permitted items to remain in the permit, items to be added, and/or items to be modified (the application form itself should include only include items to be added/modified). The narrative should also include whether any previously permitted items have been certified. ® The narrative should clearly identify the requested permitting action and accurately describe the sewers to be listed in the final permit. H. Power Reliability Plan (Required if portable reliability option utilized for Pump Station): ® Per 15A NCAC 02T .0305(h)(1), submit documentation of power reliability for pumping stations. ➢ This alternative is only available for average daily flows less than 15,000 gallons per day ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant and is compatible with the station. The Division will accept a letter signed by the applicant (see 15A NCAC 02T .0106(b)) or proposed contractor, staring that "the portable power generation unit or portable, independently -powered pumping units, associated appurtenances and personnel are available for distribution and operation of this pump station." ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. (Required at time of certification) I. Certificate of Public Convenience and Necessity (All Application Packages for Privately -Owned Public Utilities): ❑ Per 15A NCAC 02T .0115(a)(1) provide the Certificate of Public Convenience and Necessity from the North Carolina Utilities Commission demonstrating the Applicant is authorized to hold the utility franchise for the area to be served by the sewer extension, or ❑ Provide a letter from the North Carolina Utilities Commission's Water and Sewer Division Public Staff stating an application for a franchise has been received and that the service area is contiguous to an existing franchised area or that franchise approval is expected. J. Operational Agreements (Applications from HOA/POA and Developers for lots to be sold): ❑ Homc2roperty Owners' Associations ❑ Per 15A NCAC 02T .0115(c), submit the properly executed Operational Agreement (FORM: HOA). ❑ Per 15A NCAC 02T .0115(c), submit a copy of the Articles of Incorporation, Declarations and By-laws. ❑ Developers of lots to be sold ❑ Per 15A NCAC 02T .0115M submit the properly executed OOnerational Agreement (FORM: DEW For more information, visit the Division's collection systems website INSTRUCTIONS FOR FORM: FTA 05-21 & SUPPORTING DOCUMENTATION Page 2 of 3 THE COMPLETED APPLICATION PACKAGE INCLDING ALL SUPPORTING INFORMATION AND MATERIALS, SHOULD BE SENT TO THE APPROPRIATE REGIONAL OFFICE: REGIONAL OFFICE ADDRESS COUNTIES SERVED Asheville Regional Office 2090 US Highway 70 Avery, Buncombe, Burke, Caldwell, Cherokee, Water Quality Section Swannanoa, North Carolina 28778-8211 Clay, Graham, Haywood, Henderson, Jackson, (828) 296-4500 Macon, Madison, McDowell, Mitchell, Polk, (828) 299-7043 Fax Rutherford, Swain, Transylvania, Yancey Fayetteville Regional Office 225 Green Street Suite 714 Anson, Bladen, Cumberland, Harnett, Hoke, Water Quality Section Fayetteville, North Carolina 28301-5095 Montgomery, Moore, Robeson, Richmond, (910) 433-3300 Sampson, Scotland (910)486-0707 Fax Mooresville Regional Office 610 E. Center Avenue Alexander, Cabarrus, Catawba, Cleveland, Water Quality Section Mooresville, North Carolina 28115 Gaston, Iredell, Lincoln, Mecklenburg, Rowan, (704) 663-1699 Stanly, Union (704)663-6040 Fax Raleigh Regional Office 3800 Barrett Drive Chatham, Durham, Edgecombe, Franklin, Water Quality Section Raleigh, North Carolina 27609 Granville, Halifax, Johnston, Lee, Nash, (919) 791-4200 Northampton, Orange, Person, Vance, Wake, (919) 571-4718 Fax Warren, Wilson Washington Regional Office 943 Washington Square Mall Beaufort, Bertie, Camden, Chowan, Craven, Water Quality Section Washington, North Carolina 27889 Currituck, Dare, Gates, Greene, Hertford, Hyde, (252) 946-6481 Jones, Lenoir, Martin, Pamlico, Pasquotank, (252) 975-3716 Fax Perquimans, Pitt, Tyrrell, Washington, Wayne Wilmington Regional Office 127 Cardinal Drive Extension Brunswick, Carteret, Columbus, Duplin, New Water Quality Section Wilmington, North Carolina 28405 Hanover, Onslow, Pander (910)796-7215 (910)350-2004 Fax Winston-Salem Regional Office 450 W. Hanes Mill Road Suite 300 Alamance, Alleghany, Ashe, Caswell, Davidson, Davie, Forsyth, Guilford, Rockingham, Randolph, Water Quality Section Winston-Salem, North Carolina 27105 Stokes, Surry, Watauga, Wilkes, Yadkin (336) 776-9800 (336) 776-9797 Fax INSTRUCTIONS FOR FORM: FTA 05-21 & SUPPORTING DOCUMENTATION Page 3 of 3 State of North Carolina DWR Department of Environmental Quality � Division of Water Resources FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 06-21 & SUPPORTING DOCUMENTATION Application Number: W &0 d H n q ! (to be completed by l)WR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: Town of Princeton (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Federal ❑ State/County ® Municipal 3. Signature authority's name: Michael King per 15A NCAC 02T .0106(b) Title: Town Administrator 4. Applicant's mailing address: 503 Dr Donnie J Jones Blvd W City: Princeton State: NC Zip: 27569-_ 5. Applicant's contact information: Phone number: 919 936-8171 Email Address: m.king0mvorincetonnc.com ❑ Privately -Owned Public Utility ❑ Other IL PROJECT INFORMATION: I. Project name: Holts Pond Road Sewer Extension 4cv, 3 SFR 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: W000_ and issued date: For modifications, also attach a detailed narrative description as described in Item G of the checklist. If new construction, but part of a master plan, provide the existing permit number: W000_ 3. County where project is located: Johnston 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.463393' Longitude:-78.170579' 5. Parcel ID (if applicable): 04PI0136 (NCPIN: 264215-64-6732) (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Ethan Gartin License Number: 054852 Firm: TRC Companies Mailing address: 114 Edinburgh South Drive, Suite 200 City: Cary State: NC Zip: 27511-_ Phone number: (919 827-0864 Email Address: egartinatrccomoanies.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Princeton W WTP Permit Number: N0026662 Owner Name: Town of Princeton V. RECEIVING DOWNSTREAM SEWER INFORMATION: 1. PermitNumber(s): WQCS00237 2. Downstream (Receiving) Sewer Information: 8 inch ® Gravity ❑ Force Main 3. System Wide Collection System Permit Number(s) (if applicable): WQCS00237 Owner Name(s): Town of Princeton FORM: FTA 06-21 Page 1 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes [:]No ® N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEVI been attached? ❑ Yes ❑ No ® N/A 3. If the Applicant is a Home/Property Owners' Association, has an HOA/POA Operational Agreement (FORM: HOA) and supplementary documentation as required by 15A NCAC 02T.0115(c) been attached? ❑ Yes ❑ No ® N/A 4. Origin of wastewater: (check all that apply): ® Residential (Individually Owned) ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential (Leased) ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool/Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater : 100 % Domestic % Commercial _ % Industrial (See 15A NCAC 02T .0103(201) If Industrial, is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Hasa flow reduction been approved under 15A NCAC 02T .0114(f)? ❑ Yes ® No ➢ If yes, provide a copy of flow reduction approval letter with this application 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(f)) Daily Design Flow�b No. of Units Flow Residential (Individually Owned) 47 gal/day 1 47 GPD Residential (Individually Owned) 87 gal/day 1 87 GPD Residential (Individually Owned) 184 gal/day 1 184 GPD gal/ GPD gal/ GPD gal/ GPD Total 318 GPD a See 15A NCAC 02T .0114(b). (d). (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 218 GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, please indicate why: ❑ Pump Station/Force Main or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line. Please provide supplementary information indicating the approximate timeframe for permitting upstream sewers with flow. ❑ Flow has already been allocated in Permit Number: Issuance Date: ❑ Rehabilitation or replacement of existing sewers with no new flow expected ❑ Other (Explain): FORM: FTA 06-21 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 525 SDR-21 PVC ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirements is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): PROVIDE A SEPARATE COPY OF THIS PAGE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: Holts Pond Rd Pump Station 2 2. Approximate Coordinates (Decimal Degrees): Latitude: 35.469597' Longitude:-78.200519' 3. Total number of pumps at the pump station: 2 3. Design flow of the pump station: 0.036 millions gallons per day (fum capacity) ➢ This should reflect the total GPM for the pump station with the largest pump out of service. 4. Operational point(s) per pump(s): 120 gallons per minute (GPM) at 20 feet total dynamic head (TDH) 5. Summarize the force wain to be permitted (for this Pump Station): Size (inches) Length (feet) Material 4 755 C-900 PVC If any portion of the force main is less than 4-inches in diameter, please identify the method of solids reduction per MDCPSFM Section 2.01C.l.b. ❑ Grinder Pump ❑ Mechanical Bar Screen ❑ Other (please specify) 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ❑ Standby power source or ❑ Standby pump ➢ Must have automatic activation and telemetry - 15A NCAC 02T.0305(h)(1)(B)_ ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility and may not be portable Or if the pump station has an average daily flow less than 15,000 gallons per day 15A NCACO2T.0305(h)(1)(C): ® Portable power source with manual activation, quick -connection receptacle and telemetry - or ❑ Portable pumping unit with plugged emergency pump connection and telemetry: ➢ Include documentation that the portable source is owned or contracted by the applicant and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided as part of this permit application in the case of a multiple station power outage. FORM: FTA 06-21 Page 3 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permittingof Stations and Force Mains (latest version), and the Gravity Sewer Minimum Dcsign Criteria (latest version) as applicable? ® Yes ❑ No If no, for projects requiring a single variance, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review to the Central Office. Approval of the request will be issued concurrently with the approval of the Permit, and proiects requiring a variance approval may be subiect to longer review times For proiects requiring two or more variances or where the variance is determined by the Division to be a significant nortiop of the nroiect, the full technical review is required. 2. Professional Engineer's Certification: I, Ethan Gartin, Project Manager . attest that this application for Holts Pond Road Sewer Extension. (Professional Engineer's name from Application Item III.1.) (ProjectName from Application Item ILL) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains Ilatest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed SI0,000, as well as civil penalties up to $25,000 per violation. Misrepresentation of the application information, including failure to disclose any design non-compliance with the applicable Rules and design criteria, may subject the North Carolina -licensed Professional Engineer to referral to the licensing board. (21 NCAC 56.0701) North Carolina Professional Engineer's seal, signature, and date: � _..�`� ��C„ 4,R 0 zI�` SEAL. 3. Applicant's Certification per 15A NCAC 02T .0106(b): I, Michael King. Administrator . attest that this application for Holts Pond Road Sewer Extension. (Signature Authority Name from Application Item 1.3.) (Project Name from Application Item It.1) attest that this application has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non -discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143 215.6A and 143-215.6E any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, whi may include a line not to exec 10 Dos I as c' penalties up to $25.000 per violation. Signature: Date: 1` I FORM: FTA 06-21 Page 5 of 5 RECEIVEDINCDENRIDWR State of North Carolina APR 2 9 2024 Department of Environmental Quality Division of Water Resources Water Quality Regional 0pc7at10l**eTftcking/Acceptance for Sewer Extension Applications Washington Regional Office (FTSE 04-16) Entity Requesting Allocation: Town of Princeton, NC Project Name for which flow is being requested: Holts Pond Rd Sewer Extension More than one FTSE maybe requiredfor a single project if the owner of the WWTP is not responsiblefor all pump stations along the route of the proposed waslewaterjlow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Princeton WWTP b. WWTP Facility Permit #: N0026662 All flows are in MGD c. WWTP facility's permitted flow 0.275 d. Estimated obligated flow not yet tributary to the WWTP 0.001067 e. WWTP facility's actual avg. flow 0.168787 f. Total flow for this specific request 0.000218 g. Total actual and obligated flows to the facility 0.170072 h. Percent of permitted flow used 61.84% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Average Daily Approx. Not Yet Total Current Station Firm Flow** Current Avg. Tributary Flow Plus (Name or Capacity, * (Firm / pi), Daily Flow, Daily Flow, Obligated Available Number) MGD MGD MGD MGD Flow Capacity*** W Edw St 0.3096 0.12384 0.0057 0.0057 0.3039 * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is <0. Downstream Facility Name (Sewer): Princeton Wastwater Collection Downstream Permit Number: WSCS00237 Page 1 of 6 FTSE 04-16 III. Certification Statement: [ Michael King certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form indicates acceptance of thig wastewater flow. Signing Official Signature Page 2 of 6 FTSE 04-16 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)): 1. Does the project comply with all separations/altematives found in 15A NCAC 02T .0305(f) & W? ® Yes ❑ No 15A NCAC 02T.0305 contains minimum separations that shall be provided for sewers stems: Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 18 inches 'Water mains (vertical - water over sewer preferred, including in benched trenches) 18 inches 'Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water, and associated wetlands. 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands associated with these waters (see item IX.2) 50 feet "Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches, as well as wetlands associated with these waters or classified as WL. 10 feet Any building foundation (horizontal) 5 feet Any basement (horizontal) 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches ➢ If noncompliance with 02T.0305(fl or (s). see Section X.1 of this application *15A NCAC 02T.0305(e) contains alternatives where separations in 02T.0305(fl cannot be achieved. Please check "yes" above if these alternatives are used and provide narrative information to explain. **Stream classifications can be identified using the Division's NC Surface Water Classifications webnaee 2. Does this project comply with the minimum separation requirements for water mains? ® Yes ❑ No ❑ N/A ➢ If no, please refer to 15A NCAC 18C.0906(f) for documentation requirements and submit a separate document, signed/sealed by an NC licensed PE, verifying the criteria outlined in that Rule. 3. Does the project comply with separation requirements for wetlands? ® Yes ❑ No ❑ N/A ➢ Please provide supplementary information identifying the areas of non-conformance. ➢ See the Division's draft separation requirements for situations where separation cannot be met. ➢ No variance is required if the alternative design criteria specified is utilized in design and construction. 4. Is the project located in a river basin subject to any State buffer rules? ® Yes Basin name: Neuse River Basin ❑ No If yes, does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ® Yes ❑ No ➢ This includes Trout Buffered Streams per 15A NCAC 2B.0202 5. Does the project require coverage/authorization under a 404 Nationwide/individual permits ❑ Yes ® No or 401 Water Quality Certifications? ➢ Please provide the permit number/permitting status in the cover letter if coverage/authorization is required. 6. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications must be being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 7. Does this project include any sewer collection lines that are deemed "high -priority?" [-]Yes ® No Per 15A NCAC 02T.0402 "high -priority sewer" means any aerial sewer, sewer contacting surface waters, siphon, or sewers positioned parallel to streambanks that are subject to erosion that undermines or deteriorates the sewer. Siphons and sewers suspended through interference/conflict boxes require a variance approval. ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permtttee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permittee's individual System -Wide Collection permit. FORM: FTA 06-21 Page 4 of 5 RECEIVED/NCDENR/DWR �i TRC April 1, 2024 APR 2 9 2024 Water Quality Regional operations Section Washington Regional office Scott Vinson — Environmental Engineer NC DEQ — Division of Water Resources 943 Washington Square Mall Washington, NC 27889 114 Edinburgh S. Drive, Ste. 200 T 919.827.0864 Cary, NC 27511 TRCcompanies.com Project Narrative — Princeton Holts Pond Rd Sewer Extension Mr. Vinson, The purpose of this project is to provide sewer service to three specific residences which are currently experiencing failed septic systems for their sewer services. This project would extend service to these three users — one through gravity, and two through a new pump station. This pump station will require 318 gallons per day, based on the residences' last 12 months of water billing data. While the Town is under moratorium, is request is based on swapping flows with t r—ee ofFer properties listed below. NC DEQ has already reviewed and given preliminary approval for this swap. This request is made in conjunction with the previously approved request for the Martin Livestock Rd sewer extension for the Princeton Church, for which these properties were also listed. Property No. NCPIN Site Address Gallons per Da 1 265209-05-9506 102 Dr Donnie H Jones Jr Blvd, 360 Princeton, NC 27569 2 264216-94-2044 414 S Center St, 360 Princeton, NC 27569 3 264216-83-8890 427 S Pine St, 360 Princeton, NC 27569 Total — 1,080 This project will add a pump station on a property via permanent easement. The pump station and all other infrastructure will meet the minimum standards of all applicable entities, including NC DEQ. The pump station will include a wet well, valve vault, telemetry, fencing, access road, controls, two pumps, and a manual generator quick -connect plug. The pump station is designed to operate at a duty point of 120 gpm @ 20 ft TDH. It will operate based on floats, which will be used in conjunction with telemetry to turn pumps on and off at appropriate high and low water marks, as well as send out alarms to staff to indicate signs of pump failure. The project will also include a short section of gravity sewer along the road, designed to meet minimum slope standards for 8" pipe (approximately 525 LF). Also, the project will require approximately 755 LF of 4" force main along Holts Pond Road which will terminate at an existing manhole on the road. The Town's existing collection system permit number is WQ00237. Scott Vinson, NC DEQ, Project Narrative Page 2 of 2 The application package includes: • Fast Track Sewer Extension Application • FTSE 04-16 • Aerial Map • Topographic Map • Existing Collection System Permit • Cover Letter/Narrative • Proposed Power Plan • Application Fee Payment Please consider the attached application and this narrative as a formal request for the proposed fast -track extension to be permitted by your office, such that the Town can begin construction soon after the permit has been established. Sincerely, pe6 �'-- Ethan Gartin, PE Project Manager TRC April 1, 2024 Scott Vinson — Environmental Engineer NC DEQ — Division of Water Resources 943 Washington Square Mall Washington, NC 27889 114 Edinburgh S. Drive, Ste. 200 T 919.827.0864 Cary, NC 27511 TRCcompanies.com Power Plan — Princeton Holts Pond Rd Sewer Extension Mr. Vinson, The Town of Princeton will be installing a pump station along Holts Pond Road in the West part of the Town. This pump station will pump directly to the West Edwards Street pump station approximately half a mile downstream. The proposed pump station will be one of two pump stations owned and operated by the Town which do not have on -site emergency generators. The previously planned pump station for Martin Livestock Rd to serve the church was modified to be a standby, on -site generator, which is why the Town still has two portable generators to utilize for two stations once the proposed station has been installed. The proposed pump station will utilize a manual quick -connect plug that can operate using one of the Town's two existing portable generators. These generators are "pull -behind" generators, housed on a mobile trailer, to be mobilized in the event of power failure. Because the Town will have two pump stations which need portable generators, and two generators to operate those pump stations, it is therefore concluded that operational concerns should be minimal. The Town should be able to mobilize each generator to the respective pump station needed even if both pumps lose power, and the remaining pump stations will utilize the on -site emergency generators. The portable power generation units, associated appurtenances, and personnel are available for distribution and operation of the proposed pump station. Sincerely, 44es�___ - Ethan Gartin, PE Project Manager PROJECT LOCATION PROPOSED PUMP STATION �S PONp Ft O l R 25311 N PROPOSED Z FORCE MAIN ita Ediabur9h sumh otiv. suite zoo 7511 is 919Ar TIRC Nc FImnUnnaeeF0991 t`l. 11V Liles 1 1V l� 1 n C ENGINEERS,INC.• VA • Nowport News, VA •Blacksburg, VA •Northern Virginia Blahmond,cksburg, • Charlaltesvllle, VA • Virginia Beach, VA ml SEWER EXTENSION PERMIT MAP ml HOLTS POND ROAD SEWER EXTENSION a PROPOSED GRAVITY SEWER PIPE' EXISTING GRAVITY SEWER TO W EDWARDS ST PI IMP STATION At j SYSTEM WIDE COLLECTION SYSTEM PERMIT #: WQCS00237 NPDES PERMIT #: NCO026662 DESIGNED EWG PROJECT:571459 DRAWN ABM CHECKED SRG SCALE: 1" = 150' DATE APRIL 2024 PRINCETON QUADRANGLE NORTH CAROLINA 7.5-MINUTE SERIES o \ I ENtLLS \/ CREST LN/ i f 1 �T CED i 70 m n y PROJECT AREA ti ka° ncet _ c PrinII I - - N PEARL S7 b 0� DR. S * SCALE 1:24 000 MK. , 0.5 0 KILOMETERS 1 = PRINCETON NC 9' 2e' 1 1000 500 0 METERS 1000 7000 6T AVLS q t•38' 1 0.5 0 1 I—29MILS MILES 2016 1000 0 1000 2000 3000 0000 5000 6000 7000 E000 9000 70001 irtu rom eun vnu uerumr unvrx FEET