HomeMy WebLinkAboutSW6240106_Design Calculations_20240516 Project Name Riprap Dissipator#1 Date
Northgate Phase 2&3 Dec. 2023
DD Project No.
Location D&L Engineering, PLLC DL2317
Moore County, North Carolina 150 S. Page Street Calculated By
Southern Pines, NC 28387 J LH
(910)684-8646 Checked By
P-2587 J L H
STORM DESIGN: 25 Year
BACKGROUND: Use the E&S Control Planning & Design Manual, Section 8.06.
REFERENCE: (NCDEHNR, 1993)
Step 1. Minimum Tailwater Condition
Step 2. D-o= 42 in. Pipe diameter in inches
D-o = 3.50 ft. Pipe diameter in feet
Q-25= 66.80 cfs Pipe outlet(from drainage calculations)
d-50= 0.7 ft. from Figure 8.06 a
L-a = 22 ft. from Figure 8.06 a
Step 3. 3*D-o= 10.50 ft. 3 times the outlet pipe diameter
W= 25.50 ft. Pipe diameter+Apron length
Step 4. d-max 1.05 ft. Maximum Stone Diameter(1.5*d-50) in inches
d-max 13 in. Maximum Stone Diameter(1.5*d-50) in feet
Step 5. Thickness= 1.58 ft. Min. Apron Thickness With Filter Fabric (1.5*d-max) in feet
Thickness= 19 in. Min. Apron Thickness With Filter Fabric (1.5*d-max) in inches
DESIGN DIMENSIONS: Apron Dimensions Riprap
Length Width 3*D-o Thick Class
22 26 11 36in. 2
TERMINOLOGY: Q10 = 10-Year Design Storm, Peak Discharge, (cfs)
D-o= Pipe Diameter, (in. &ft.)
d-50= Mean Stone Diameter of Rip-Rap, (ft.)
L-a = Length of Rip-Rap Apron, (ft.)
3`D-o = Width of Rip-Rap Apron @ Pipe Outlet, (ft.)
W = Width of Rip-Rap Apron @ End of Apron, (ft.)
d-max= Maximum Stone Diameter of Rip-Rap, (ft. & in.)
Thickness = Thickness of Rip-Rap Apron With Filter Fabric, (ft. &in.)
Project Name Riprap Dissipator #2 Date
Northgate Phase 2&3 Dec. 2923
DD Project No.
Location D&L Engineering, PLLC DL23I7
Moore County, North Carolina 150 S. Page Street Calculated By
Southern Pines, NC 28387 J I H
(910)684-8646 Checked By
P-2587 JLH
STORM DESIGN: 25 Year
BACKGROUND: Use the E&S Control Planning & Design Manual, Section 8.06.
REFERENCE: (NCDEHNR, 1993)
Step 1. Minimum Tailwater Condition
Step 2. D-o = 18 in. Pipe diameter in inches
D-o = 1.50 ft. Pipe diameter in feet
Q-25= 9.20 cfs Pipe outlet(from drainage calculations)
d-50= 0.3 ft. from Figure 8.06 a
L-a = 9 ft. from Figure 8.06 a
Step 3. 3"D-o= 4.50 ft. 3 times the outlet pipe diameter
W= 10.50 ft. Pipe diameter+Apron length
Step 4_ d-max 0.45 ft. Maximum Stone Diameter(1.5"d-50) in inches
d-max 5 in. Maximum Stone Diameter(1.5"d-50) in feet
Step 5. Thickness = 0.68 ft. Min. Apron Thickness With Filter Fabric(1.5"d-max) in feet
Thickness = 8 in. Min. Apron Thickness With Filter Fabric(1.5`d-max) in inches
DESIGN DIMENSIONS: Apron Dimensions Riprap
Length Width 3"D-o Thick Class
9 11 5 18in. B
TERMINOLOGY: Q10= 10-Year Design Storm, Peak Discharge, (cfs)
D-o = Pipe Diameter, (in. &ft.)
d-50 = Mean Stone Diameter of Rip-Rap, (ft.)
L-a = Length of Rip-Rap Apron, (ft.)
3*D-o= Width of Rip-Rap Apron @ Pipe Outlet, (ft.)
W= Width of Rip-Rap Apron @ End of Apron, (ft.)
d-max= Maximum Stone Diameter of Rip-Rap, (ft. &in.)
Thickness= Thickness of Rip-Rap Apron With Filter Fabric, (ft. &in.)
Project Name Riprap Dissipator#3 Date
Northgate Phase 2&3 Dec. 2023
DD Project No.
Location D&L Engineering, PLLC DL2317
Moore County, North Carolina 150 S. Page Street Calculated By
Southern Pines, NC 28387 JLH
(910)684-8646 Checked By
P-2587 J L H
STORM DESIGN: 25 Year
BACKGROUND: Use the E&S Control Planning & Design Manual, Section 8.06.
REFERENCE: (NCDEHNR, 1993)
Step 1. Minimum Tailwater Condition
Step 2. D-o= 24 in. Pipe diameter in inches
D-o= 2.00 ft. Pipe diameter in feet
Q-25= 7.70 cfs Pipe outlet(from drainage calculations)
d-50 = 0.4 ft. from Figure 8.06 a
L-a = 12 ft. from Figure 8.06 a
Step 3. 3*D-o = 6.00 ft. 3 times the outlet pipe diameter
W= 14.00 ft. Pipe diameter+Apron length
Step 4. d-max 0.60 ft. Maximum Stone Diameter(1.5*d-50) in inches
d-max 7 in. Maximum Stone Diameter(1.5*d-50) in feet
Step 5. Thickness = 0.90 ft. Min. Apron Thickness With Filter Fabric(1.5*d-max) in feet
Thickness = 11 in. Min. Apron Thickness With Filter Fabric(1.5*d-max) in inches
DESIGN DIMENSIONS: Apron Dimensions Riprap
Length Width 3*D-o Thick Class
12 14 6 24in. 1
TERMINOLOGY: Q10 = 10-Year Design Storm, Peak Discharge, (cfs)
D-o= Pipe Diameter, (in. &ft.)
d-50= Mean Stone Diameter of Rip-Rap, (ft.)
L-a = Length of Rip-Rap Apron, (ft.)
3*D-o= Width of Rip-Rap Apron @ Pipe Outlet. (ft.)
W= Width of Rip-Rap Apron @ End of Apron, (ft.)
d-max= Maximum Stone Diameter of Rip-Rap, (ft. & in.)
Thickness = Thickness of Rip-Rap Apron With Filter Fabric, (ft. &in.)
Project Name Riprap Dissipator#4 Date
Northgate Phase 2&3 Dec. 2023
DD Project No.
Location D&L Engineering, PLLC DL2317
Moore County, North Carolina 150 S. Page Street Calculated By
Southern Pines, NC 28387 .1LH
(910)684-8646 Checked By
P-2587 .1 L H
STORM DESIGN: 25 Year
BACKGROUND: Use the E&S Control Planning & Design Manual, Section 8.06.
REFERENCE: (NCDEHNR, 1993)
Step 1. Minimum Tailwater Condition
Step 2. D-o= 18 in. Pipe diameter in inches
D-o= 1.50 ft. Pipe diameter in feet
Q-25= 6.00 cfs Pipe outlet(from drainage calculations)
d-50= 0.3 ft. from Figure 8.06 a
L a = 9 ft. from Figure 8.06 a
Step 3. 3*D-o = 4.50 ft. 3 times the outlet pipe diameter
W= 10.50 ft. Pipe diameter+Apron length
Step 4. d-max 0.45 ft. Maximum Stone Diameter (1.5*d-50) in inches
d-max 5 in. Maximum Stone Diameter(1.5*d-50) in feet
Step 5. Thickness= 0.68 ft. Min. Apron Thickness With Filter Fabric (1.5*d-max) in feet
Thickness = 8 in. Min. Apron Thickness With Filter Fabric (1.5*d-max) in inches
DESIGN DIMENSIONS: Apron Dimensions Riprap
Length Width 3*D-o Thick Class
9 11 5 1 Sin. B
TERMINOLOGY: Q10= 10-Year Design Storm, Peak Discharge, (cfs)
D-o= Pipe Diameter, (in. & ft.)
d-50= Mean Stone Diameter of Rip-Rap, (ft.)
L-a = Length of Rip-Rap Apron, (ft.)
3*D-o = Width of Rip-Rap Apron @ Pipe Outlet, (ft.)
W= Width of Rip-Rap Apron @ End of Apron, (ft.)
d-max = Maximum Stone Diameter of Rip-Rap, (ft. & in.)
Thickness = Thickness of Rip-Rap Apron With Filter Fabric, (ft. &in.)
Project Name Riprap Dissipator#5 Date
Northgate Phase 2&3 Dec. 2023
DD Project No.
Location D&L Engineering, PLLC DL2317
Moore County, North Carolina 150 S. Page Street Calculated By
Southern Pines, NC 28387 JLH
(910)684-8646 Checked By
P-2587 .1 L H
STORM DESIGN: 25 Year
BACKGROUND: Use the E&S Control Planning& Design Manual, Section 8.06.
REFERENCE: (NCDEHNR. 1993)
Step 1. Minimum Tailwater Condition
Step 2. D-o= 24 in. Pipe diameter in inches
D-o = 2.00 ft. Pipe diameter in feet
Q-25 = 14.90 cfs Pipe outlet (from drainage calculations)
d-50 = 0.4 ft. from Figure 8.06 a
L-a = 12 ft. from Figure 8.06 a
Step 3. 3*D-o= 6.00 ft. 3 times the outlet pipe diameter
W= 14.00 ft. Pipe diameter+ Apron length
Step 4. d-max 0.60 ft. Maximum Stone Diameter(1.5*d-50) in inches
d-max 7 in. Maximum Stone Diameter (1.5*d-50) in feet
Step 5. Thickness = 0.90 ft. Min. Apron Thickness With Filter Fabric(1.5*d-max) in feet
Thickness = 11 in. Min. Apron Thickness With Filter Fabric(1.5*d-max) in inches
DESIGN DIMENSIONS: Apron Dimensions Riprap
Length Width 3*D-o Thick Class
12 14 6 24in. 1
TERMINOLOGY: Q10= 10-Year Design Storm, Peak Discharge, (cfs)
D-o = Pipe Diameter, (in. &ft.)
d-50 = Mean Stone Diameter of Rip-Rap, (ft.)
L-a = Length of Rip-Rap Apron, (ft.)
3*D-o= Width of Rip-Rap Apron @ Pipe Outlet, (ft.)
W= Width of Rip-Rap Apron @ End of Apron, (ft.)
d-max= Maximum Stone Diameter of Rip-Rap, (ft. &in.)
Thickness= Thickness of Rip-Rap Apron With Filter Fabric. (ft. &in.)
Project Name Riprap Dissipator#6 Date
Northgate Phase 2&3 Dec.2023
DD Project No.
Location D&L Engineering, PLLC DL2317
Moore County, North Carolina 150 S. Page Street Calculated By
Southern Pines, NC 28387 JLH
(910)684-8646 Checked By
P-2587 JLH
STORM DESIGN: 25 Year
BACKGROUND: Use the E&S Control Planning & Design Manual, Section 8.06.
REFERENCE: (NCDEHNR: 1993)
Step 1. Minimum Tailwater Condition
Step 2. D-o = 24 in. Pipe diameter in inches
D-o = 2.00 ft. Pipe diameter in feet
Q-25 = 14.90 cfs Pipe outlet (from drainage calculations)
d-50= 0.4 ft. from Figure 8.06 a
L-a = 12 ft. from Figure 8.06 a
Step 3. 3*D-o= 6.00 ft. 3 times the outlet pipe diameter
W= 14.00 ft. Pipe diameter+Apron length
Step 4. d-max 0.60 ft. Maximum Stone Diameter (1.5"d-50) in inches
d-max 7 in. Maximum Stone Diameter(1.5*d-50) in feet
Step 5. Thickness = 0.90 ft. Min.Apron Thickness With Filter Fabric (1.5*d-max) in feet
Thickness= 11 in. Min. Apron Thickness With Filter Fabric (1.5*d-max) in inches
DESIGN DIMENSIONS: Apron Dimensions Riprap
Length Width 3*D-o Thick Class
12 14 6 24in. 1
TERMINOLOGY: Q10= 10-Year Design Storm, Peak Discharge, (cfs)
D-o= Pipe Diameter. (in. & ft.)
d-50= Mean Stone Diameter of Rip-Rap, (ft.)
L-a = Length of Rip-Rap Apron, (ft.)
3*D-o = Width of Rip-Rap Apron @ Pipe Outlet, (ft.)
W = Width of Rip-Rap Apron @ End of Apron, (ft.)
d-max= Maximum Stone Diameter of Rip-Rap, (ft. & in.)
Thickness= Thickness of Rip-Rap Apron With Filter Fabric, (ft. &in.)
Project Name Riprap Dissipator#7 Date
Northgate Phase 2&3 Dec. 2023
DD Project No.
Location D&L Engineering, PLLC DL2317
Moore County, North Carolina 150 S. Page Street Calculated By
Southern Pines, NC 28387 .1LH
(910)684-8646 Checked By
P-2587 JLH
STORM DESIGN: 25 Year
BACKGROUND: Use the E&S Control Planning & Design Manual, Section 8.06.
REFERENCE: (NCDEHNR. 1993)
Step 1. Minimum Tailwater Condition
Step 2. D-o = 24 in. Pipe diameter in inches
D-o= 2.00 ft. Pipe diameter in feet
Q-25= 16.80 cfs Pipe outlet(from drainage calculations)
d-50 = 0.4 ft. from Figure 8.06 a
L-a = 12 ft. from Figure 8.06 a
Step 3. 3*D-o = 6.00 ft. 3 times the outlet pipe diameter
W= 14.00 ft. Pipe diameter+Apron length
Step 4. d-max 0.60 ft. Maximum Stone Diameter(1.5*d-50) in inches
d-max 7 in. Maximum Stone Diameter(1.5*d-50) in feet
Step 5. Thickness= 0.90 ft. Min. Apron Thickness With Filter Fabric(1.5*d-max) in feet
Thickness= 11 in. Min. Apron Thickness With Filter Fabric(1.5*d-max) in inches
DESIGN DIMENSIONS: Apron Dimensions Riprap
Length Width 3*D-o Thick Class
12 14 6 24in. 1
TERMINOLOGY: Q10 = 10-Year Design Storm, Peak Discharge, (cfs)
D-o= Pipe Diameter, (in. &ft.)
d-50= Mean Stone Diameter of Rip-Rap, (ft.)
L-a= Length of Rip-Rap Apron, (ft.)
3*D-o = Width of Rip-Rap Apron @ Pipe Outlet, (ft.)
W = Width of Rip-Rap Apron @ End of Apron, (ft.)
d-max = Maximum Stone Diameter of Rip-Rap, (ft. & in.)
Thickness= Thickness of Rip-Rap Apron With Filter Fabric, (ft. &in.)