HomeMy WebLinkAboutWake_Well Abandonment_20240514 (2) WELL ABANDONMENT RECORD For lnternal Use ONLY:
1.Well Contractor Information: WELL ABANDONMENT DETAILS
Nathaniel Newman
7a.For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same
Well Contractor Name(or well owner personally abandoning well on his/her property) well construction/depth,only 1 GWJ30i is needed. Indicate TOTAL NUMBER of
4630C wells abandoned:
NC Well Contractor Certification Number 7b.Approximate volume of water iremaining in well(s): (gal.)
CATLI N Engineers and Scientists FOR WATER SUPPLY WELLS ONLY:
Company Name
7c.Type of disinfectant used:
2.Well Construction Permit#: A L
List all applicable well construction permits(i.e.UIC,County,State, Variance,etc)iflrnown
7d.Amount of disinfectant used:
3.Well use(check well use): a.
Water Supply Well: 7e.Sealing materials used(check all that apply):
❑Agricultural ❑MunicipaUPublic ❑Neat Cement Grout a Bentonite Chips or Pellets
❑Geothermal(Heating/Cooling Supply) ❑Residential Water Supply(single) ❑ Sand Cement Grout ❑ Dry Clay
❑Industrial/Commercial ❑Residential Water Supply(shared) ❑Concrete Grout ❑ Drill Cuttings
❑hrigation ❑ Specialty Grout ❑ Gravel
Non-Water Supply Well: 'El Bentonite Slurry N Other(explain under 7g)
RMonitoring ❑Recovery
Injection Well: 7f.For each material selected above,provide amount of materials used:
❑Aquifer Recharge ❑GroundwaterRemediation Bentonite 40lbs
❑Aquifer Storage and Recovery ❑Salinity Barrier
❑Aquifer Test ❑Stormwater Drainage Concrete 25 Ibs
❑Experimental Technology ❑Subsidence Control
7g.Provide a brief description of the abandonment procedure:
❑Geothermal(Closed Loop) ❑Tracer
❑Geothermal(Heating/Cooling Return) ❑Other(explain under 7g) Well abandoned in place with hydrated bentonite
pellets to within 6 inches of the surface and topped
a.Date well(s)abandoned: 4/10/2024 with concrete to existing grade.
5a.Well location:
Bobby and Anne B. Harrington NA
Facility/Owner Name Facility ID#(if applicable) 8.Certification:
1200 Broad Street, Fuquay-Varina, NC 27526 4/II/2024
Physical Address,City,and Zip Signature of Certified Well Contractor or,Well Owner Date
Wake 0657931229
By signing this form, 1 hereby cerl fy that the tvell(s) was (were) abandoned in
County Parcel Identification No.(PIN) accordance with 15A NCAC 02C.0100 or 2C.0200 Well Construction Standards
and that a copy of this record has been provided to the well owner.
5b.Latitude and longitude in degrees/minutes/seconds or decimal degrees: il
(if well field,one lat/long is sufficient) 9.Site diagram or additional well'details:
35.599613 N -78.801153 W You may use the back of this page to provide additional well site details or well
abandonment details. You may also attach additional pages if necessary.
CONSTRUCTION DETAILS OF WELL(S)BEING ABANDONED
SUBMITTAL INSTRUCTIONS
Attach well construction record(s)tfavailable. For multiple injection anon-water supply wells
ONLrwith the same constructionlabandonment,you can submit one form.
10a. For All Wells: Submit this form within 30 days of completion of well
6a.Well ID#: MW-02 abandonment to the following:
Division of Water Resources,Information Processing Unit,
6b.Total well depth: 20 (ft.) 1617 Mail Service Center,Raleigh,NC 27699-1617
10b.For Iniection Wells: In addition to sending the form to the address in I Oa
6c.Borehole diameter: 8.25 (in) above, also submit one copy of this form within 30 days of completion of well
abandonment to the following:
i
6d.Water level below ground surface 1 3.45 --(ft.) Division of Water Resources,Underground Injection Control Program,
1636 Mail Service Clenter,Raleigh,NC 27699-1636
6e.Outer casing length(if known): NA (ft.) 10c.For Water Supply&Injection Wells: In addition to sending the form to the
address(es)above,also submit one copy of this form within 30 days of completion
of well abandonment to the county health department of the county where
6C Inner casing/tubing length(if known): 10 (ft.) abandoned.
6g.Screen length(if known): 10 (ft.)
Form GW-30 North Carolina Department of Environmental Quality-Division of Water Resourcesi Revised 2-22-2016