Loading...
HomeMy WebLinkAboutSW6240203_Supplement-EZ Form_20240511 SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION 1 Project Name Erwin Harbor Frieght 2 Project Area(ac) 1.526 3 Coastal Wetland Area(ac) 0 4 Surface Water Area(ac) 0 5 Is this project High or Low Density? Both High and Low Density 6 Does this project use an off-site SCM? No COMPLIANCE WITH 02H.1003(4) 7 Width of vegetated setbacks provided(feet) 50 8 Will the vegetated setback remain vegetated? N/A 9 If BUA is proposed in the setback,does it meet NCAC 02H.1003(4)(c-d)? N/A 10 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: 11 Infiltration System 12 Bioretention Cell 13 Wet Pond 14 Stormwater Wetland 15 Permeable Pavement 16 Sand Filter 1 17 Rainwater Harvesting(RWH) 18 Green Roof 19 Level Spreader-Filter Strip(LS-FS) 20 Disconnected Impervious Surface(DIS) 21 Treatment Swale 22 Dry Pond 23 StormFilter 24 Silva Cell 25 Bayfilter 26 Filterra FORMS LOADED DESIGNER CERTIFICATION 27 Name and Title: Marie Peedin, President 28 Organization: Inner Banks Engineering,PC 29 Street address: 128 East 2nd Street 30 City,State,Zip: Washington,NC 27889 31 Phone number(s): 2529452983 32 Email: mupeedin@ibxengineering.com Certification Statement: I certify,under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision;that the information provided in the form is,to the best of my knowledge and belief,true,accurate,and complete;and that the engineering plans, specifications,operation and maintenance agreements and other supporting information are consistent with the information provided here. Designer //AA .���P�H CAigO '�i �..'tO pEssip•(.1%)•� C Signature of Designer SEAL,p0212 Z 4's ;'pHLE• 5/11/24 I//11111111 Seal Date DRAINAGE AREAS 1 Is this a high density project? Yes 2 If so,number of drainage areas/SCMs 1 3 Does this project have low density areas? Yes 4 If so,number of low density drainage areas 1 Is all/part of this project subject to previous rule 5 versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site 1 LD 1 4 Type of SCM Sand Filter sandfilter 5 Total drainage area(sq ft) 66484 48146 18338 6 Onsite drainage area(sq ft) 66484 48146 18338 7 Offsite drainage area(sq ft) 0 8 Total BUA in project(sq ft) 44431 sf 40033 sf 4398 sf New BUA on subdivided lots(subject to permitting) 9 (sq ft) sf New BUA not on subdivided lots(subject to 10 permitting)(sf) sf 11 Offsite BUA(sq ft) sf 12 Breakdown of new BUA not on subdivided lots: -Parking(sq ft) 26202 sf 22347 sf 3855 sf -Sidewalk(sq ft) 2229 sf 1686 sf 543 sf -Roof(sq ft) 16000 sf 16000 sf -Roadway(sq ft) -Future(sq ft) -Other,please specify in the comment box below(sq ft) New infiltrating permeable pavement on 13 subdivided lots(sq ft) sf New infiltrating permeable pavement not on 14 subdivided lots(sq ft) sf Existing BUA that will remain(not subject to 15 permitting)(sq ft) sf 16 Existing BUA that is already permitted(sq ft) sf 17 Existing BUA that will be removed(sq ft) sf 18 Percent BUA 67% 83% 24% 19 Design storm(inches) 1.0 in 1.0 in 1.0 in 20 Design volume of SCM(cu ft) 2402 cf 2402 cf na 21 Calculation method for design volume Simple Method simple na ADDITIONAL INFORMATION Please use this space to provide any additional information about the 22 drainage area(s): SAND FILTER 1 Drainage area number 1 2 Minimum required treatment volume(cu ft) 2402 sf GENERAL MDC FROM 02H.1050 3 Is the SCM sized to treat the SW from all surfaces at build-out? Yco 4 Is the SCM located away from contaminated soils? Yes 5 What are the side slopes of the SCM(H:V)? :1 6 Does the SCM have retaining walls,gabion walls or other engineered Yes side slopes? 7 Are the inlets,outlets,and receiving stream protected from erosion Yes (10-year storm)? 8 Is there an overflow or bypass for inflow volume in excess of the Yes design volume? 9 What is the method for dewatering the SCM for maintenance? Pump(preferred) 10 If applicable,will the SCM be cleaned out after construction? Yes 11 Does the maintenance access comply with General MDC(8)? Yes 12 Does the drainage easement comply with General MDC(9)? Yes If the SCM is on a single family lot,does(will?)the plat comply with 13 General MDC(10)? N/A 14 Is there an O&M Agreement that complies with General MDC(11)? Yes 15 Is there an O&M Plan that complies with General MDC(12)? Yes 16 Does the SCM follow the device specific MDC? Yes 17 Was the SCM designed by an NC licensed professional? Yes SAND FILTER MDC FROM 02H.1056 18 SHWT elevation(fmsl) 190 19 Type of sand filter(open or closed) Open 20 If closed,will the filter will be pre-cast or pour-in-place? Cast in Place 21 If closed,top of grate elevation(fmsl) _ 195 22 Is this sand filter designed to attenuate peak flows? Yes Sediment Chamber 23 Volume that can be retained in the sediment chamber(cubic feet) 1499 cf 24 Will there be a permanent pool in the sediment chamber? Yes _ 25 Bottom of the sediment chamber(fmsl) 189.50 26 Area of the sediment chamber(square feet) 999 sf 27 Physical depth of the sediment chamber(inches) 42 in 28 Ponding depth in the sediment chamber,above any permanent pool 18 in (inches) 29 Elevation of top of weir between chambers(fmsl) 193 Sand Chamber 30 Volume that can be retained in the sand chamber(cubic feet) 1499 cf 31 Bottom of the sand chamber(fmsl) 189.50 32 Area of the sand chamber(square feet) 999 sf 33 Physical depth of the sand chamber(inches) 24 in 34 Ponding depth in the sand chamber,above the sand surface 18 in (inches) _ 35 Elevation of the bypass device(fmsl) 193 36 Type of bypass device weir 37 Mechanism for distributing flow over the sand surface multipe openings 38 Sand specification for sand chamber ASTM C33 39 Depth above underdrain pipe(inches) 18 in 40 Will the media be maintained to drain at least two inches per hour at Yes the sand surface? 41 Is at least one clean-out pipe provided at the low point of each Yes underdrain line? 42 Will clean-out•i•es be ca••ed? Yes ADDITIONAL INFORMATION 43 Please use this space to provide any additional information about the sand filter(s): 5.A cast in place structure has been designed with vertical walls to provide adequate containement for the SCM.0:1 slopes for wall. 19. The design is an open sand filter with a closed bottom. There is no cover on the structure. The top elevation is 195.0'. Sand Filter 1 12:52 PM 8/14/2024