WQ0045378_Application_20240509
Initial Review Reviewer nathaniel.thorn burg Is this submittal an application? (Excluding additional information.) * Yes No Permit Number (IR) * WQ0045378 Applicant/Permittee Town of Holly Springs Applicant/Permittee Address 128 S Main Street, Holly Springs, NC 27540 Is the owner in BIMS? Yes No Is the facility in BIMS? Yes NO Owner Type Facility Name County Fee Category RW Distribution Line Is this a complete application?* Yes No Signature Authority Signature Authority Title Signature Authority Email Document Type (if non -application) Email Notifications Municipal Goodwin (Yield North) Infrastructure Phases I and II RWDL Wake Does this need review by the hydrogeologist? * Yes No Regional Office CO Reviewer Admin Reviewer Fee Amount $600 Complete App Date 05/09/2024 Below list any additional email address that need notification about a new project. Email Address Comments to be added to email notfication Comments for Admin Comments for RO Comments for Reviewer Comments for Applicant Submittal Form Project Contact Information Please provide information on the person to be contacted by NDB Staff regarding electronic submittal, confirmation of receipt, and other correspondence. Name* Emily Koncz Email Address* emily.koncz@hollyspringsnc.gov Project Information Application/Document Type* New (Fee Required) Modification - Major (Fee Required) Renewal with Major Modification (Fee Required) Annual Report Additional Information Other Phone Number* 9195572933 Modification - Minor Renewal GW-59, NDMR, NDMLR, NDAR-1, N DAR-2 Residual Annual Report Change of Ownership We no longer accept these monitoring reports through this portal. Please click on the link below and it will take you to the correct form. https://edoes.deq.nc.gov/Forms/NonDischarge_Monitoring_Report Permit Type:* Wastewater Irrigation High -Rate Infiltration Other Wastewater Reclaimed Water Closed -Loop Recycle Residuals Single -Family Residence Wastewater Other Irrigation Applicant/Permittee* Town of Holly Springs Applicant/Permittee Address* 128 S Main Street, Holly Springs, NC 27540 Facility Name* Goodwin (Yield North) Infrastructure Phases I and II RWDL Please provide comments/notes on your current submittal below. Permit Application fee sent by Crescent Communities, Check number 33807 At this time, paper copies are no longer required. If you have any questions about what is required, please contact Nathaniel Thornburg at nathaniel.thornburg@ncdenr.gov. Please attach all information required or requested for this submittal to be reviewed here. (Application Form, Engineering Plans, Specifications, Calculations, Etc.) —42196—Goodwin—Yield—North Complete Reclaim Permit 52.97MB Application.pdf Upload only 1 PDF document (less than 250 MB). Multiple documents must be combined into one PDF file unless file is larger than upload limit. * By checking this box, I acknowledge that I understand the application will not be accepted for pre -review until the fee (if required) has been received by the Non -Discharge Branch. Application fees must be submitted by check or money order and made payable to the North Carolina Department of Environmental Quality (NCDEQ). I also confirm that the uploaded document is a single PDF with all parts of the application in correct order (as specified by the application). Mail payment to: NCDEQ — Division of Water Resources Attn: Non -Discharge Branch 1617 Mail Service Center Raleigh, NC 27699-1617 Signature <Y� 6t'_W_._2 Submission Date 5/6/2024 DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C Hors y 1876... 0 0 oa$` THE TOWN OF OilJpnngs �O NOW April April 19, 2024 NCDEQ — Division of Water Resources Water Quality Permitting Section, Non -Discharge Permitting Unit 1617 Mail Service Center Raleigh, NC 27699-1617 Re: Holly Springs Reclaimed Water Distribution System Extension Request; Application for Approval Project: RECLAIMED Water — Goodwin (Yield North) Infrastructure Ph I and II Dear Sir or Madam: Please find enclosed the following items in application for a RECLAIMED water extension permit to the Town of Holly Springs' existing reclaimed water distribution system: ❑ One copy of the State application ❑ One copy of Instructions ❑ One copy of the locally -required Reclaimed Water Extension Design and Application Certification (Form 3016) ❑ One copy of the Town Engineering Design and Construction Standards Reclaimed Water Distribution System Section - to be used for the project in conjunction with the State's extension standards ❑ One copy of No Impact Letter ❑ One copy of plats Feel free to contact me at 919-577-3150 should you have any questions or need additional information in order to process this application. Sincerely, DocuSigned by: "P A3B6E125C87C4AE... Kendra D. Parrish, P.E., C.F.M Executive Director of Utilities and Infrastructure Services KDP/ek cc: Project Consultant Engineer, Brandon McLamb Rachel Jones, Utility Engineer Catherine Jacobs, Development Engineering Manager Seann Byrd, Deputy Director of Water Resources DS ID DS c Rachel Jones Catherine Jacobs 3017 07.24.23 Utilities and Infrastructure Services P.O. Box 8 • 128 S. Main Street • Holly Springs, NC 27540 • www.hollyspringsnc.gov DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C Hors y 1876... 0 0 oa$` THE TOWN OF OilJpnngs �O NOICfK�A Project file/paper/electronic/Correspondence 9 42196 3017 07.24.23 Utilities and Infrastructure Services P.O. Box 8 • 128 S. Main Street • Holly Springs, NC 27540 • www.hollyspringsnc.gov DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C DO NOT SUBMIT RECLAIMED WATER EXTENSION APPLICATION UNTIL CONSTRUCTION DRAWINGS HAVE BEEN APPROVED BY STAFF! RECLAIMED Water Distribution Extension Design & Application Certification Note: This form must be submitted with Permits for Extensions to the Town of Holly Springs RECLAIMED Water System Project: Goodwin (Yield North) Infrastructure Phase I & II Design Engineer: Brandon McLamb Address: 5410 Trinity Rd, Suite 102, Raleigh, NC 27607 Phone Number: (919) 866-4935 Email: brandon.mclamb@timmons.com Date Complete Application Package Received by Town: 5/3/2024 DS DS Ub Date Approved:F(by RJ) cup (by KDP) C'� (by CJ) As design engineer for this project, I certify the following (please check (x) each applicable box): ® That the design of the project is in complete conformance with Town of Holly Springs Engineering Design and Construction Standards and the State of North Carolina NC DEQ. ❑ That each of the following items are completed and enclosed for submittal to the State for a RECLAIMED Water Distribution System Permit: ® One copy of Reclaimed Instructions ® One copy of a Reclaimed Water extension permit application for the project ❑ One set of sealed construction drawings, as approved by the Town of Holly Springs. All comments by the Town of Holly Springs are addressed and reflected on the plans. In addition, the plans must include all of the information required per Section 15A NCAC 2T.0100 and .0900. PENDING APPROVAL KI Owner Certification Letter ❑ A check for Town processing fee is enclosed WILL BE PROVIDED ❑ A check to NC DEQ is enclosed UPON TOWN APPROVAL Design Engineer's Signature Date 02/12/2024 For your information, a copy of the Town's Engineering Design and Construction Standards (RECLAIMED Water Distribution System Section 11.00) will be forwarded to the State along with these plans. Please contact Emily Koncz at emily.konczkholl. sspringsnc.gov if you have any questions. 3016. Utilities and Infrastructure Services 01.25.21 P.O. Box 8 a 128 S. Main Street a Holly Springs, NC 27540 • www.hollyspringsnc.gov DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C �~0w0,0. 0 • TIMMONS GROUP YOUR VISION ACHIEVED THROUGH OURS. 02/09/2024 Scott Vinson, WRWQROS Regional Supervisor State of North Carolina Department of Environmental Quality Raleigh Regional Office Water Quality Section 3800 Barrett Drive Raleigh, NC 27609 5410 Trinity Road P 919.866.4951 Suite 102 F 919.859.5663 Raleigh, NC 27607 www.timmons.com Reclaimed Water Systems — Distribution Lines — The Goodwin (Yield North) Infrastructure Phase I & II Mr. Vinson, Timmons Group is pleased to submit the following Reclaimed Water Systems — Distribution Lines Application on behalf of The Town of Holly Springs. This application is being submitted to request the addition of the Goodwin (Yield North) Infrastructure Phase I and II reclaimed waterline infrastructure located in the proposed development off Woods Creek Road that connects to the Town of Holly Springs' existing reclaimed water system. This project consists of the following components: 2,581 feet of six-inch (F) Purple PVC pipe, 60 feet of six-inch (F) Ductile Iron pipe, and 1,566 feet of twelve -inch (12") Purple PVC pipe. This reclaimed water system is designed to serve build -out of the Yield North development. The proposed 12" alignment along Woods Creek Road will tie into an existing reclaimed waterline further along Woods Creek Road owned by the Town of Holly Springs. This project requires authorization under a 404 Nationwide permit. The permits have been approved and include The Woods Creek Road Widening project with the NCDWR Project No. 20221757 v.2 and Certification No. 6329 as well as The Goodwin Commercial Development project/The Yield North Master Plan with the USACE ID SAW-2023- 01841 and a Certification No. WQC006399. This application includes a transmittal, cover letter, Distribution Lines RWDL application, RWPI form, Developer Certification of Ownership letter, and a Reclaimed Water Design and Application Certification form. We look forward to hearing from you regarding this review. If you have any questions or need any additional information, please don't hesitate to contact me at 919.866.4935 or Brandon. McLamb(a)timmons.com at your convenience. Sincerely, Brandon McLamb, PE Project Manager 919.866.4935 CIVIL ENGINEERING I ENVIRONMENTAL I SURVEYING I GIS I LANDSCAPE ARCHITECTURE I CONSTRUCTION SERVICES DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C State of North Carolina nlwAllp Department of Environmental Quality Division of Water Resources 15A NCAC 02U — RECLAIMED WATER SYSTEMS — DISTRIBUTION LINES Division of Water Resources INSTRUCTIONS FOR FORM: RWDL 06-16 & SUPPORTING DOCUMENTATION Please use the following instructions as a checklist in order to ensure all required items are submitted. Adherence to these instructions and checking the provided boxes will help produce a quicker review time and reduce the amount of additional information requested. Failure to submit all of the required items will lead to additional processing and review time for the permit application. For more information, visit the Water Quality Permitting Section's Non -Discharge Permitting Unit website General — This application is for projects involving the construction of reclaimed water distribution lines that will supply reclaimed water for conjunctive use activities. Unless otherwise noted, the Applicant shall submit one original and two copies of the application and supporting documentation. Do not submit this application without an associated Reclaimed Water Project Information (FORM: RWPI) form. A. Reclaimed Water Distribution Lines (FORM: RWDL 06-16) Application (All application packages): ® Submit the completed and appropriately executed Reclaimed Water Distribution Lines (FORM: RWDL 06-16) form. Please do not make any unauthorized content changes to this form. If necessary for clarity or due to space restrictions, attachments to the application may be made, as long as the attachments are numbered to correspond to the section and item to which they refer. ® The system name in Item II.1. shall be consistent with the user name on the plans, specifications, agreements, etc. ® The Professional Engineer's Certification on Page 5 of this form shall be signed, sealed and dated by a North Carolina licensed Professional Engineer. ® The Applicant's Certification on Page 5 of this form shall be signed in accordance with 15A NCAC 02T .0106(b). The application must be signed by a principal executive officer of at least the level of vice-president or his authorized representative for a corporation; by a general partner for a partnership or limited partnership; by the proprietor for a sole proprietorship; and by either an executive officer, an elected official in the highest level of elected office, or other authorized employee for a municipal, state, or other public entity. An alternate person may be designated as the signing official if a delegation letter is provided from a person who meets the criteria in 15A NCAC 02T .0106(b). B. Property Ownership Documentation (All Application Packages): ® Per 15A NCAC 02U .0201(e) or 15A NCAC 02U .0202(f), the Applicant shall demonstrate that they are the owner of the property where the reclaimed water lines will be installed. Documentation shall consist of one of the following (or a combination of): ® Legal documentation of ownership (i.e., GIS, deed or article of incorporation), or ❑ Written notarized intent to purchase agreement signed by both parties with a plat or survey map, or ❑ An easement specifically indicating the intended use of the property and meeting the requirements of 15A NCAC 02L .0107 , (i.e. municipality right of way) or ❑ A written notarized lease agreement signed by both parties, indicating the intended use of the property, as well as a plat or survey map. INSTRUCTIONS FOR FORM: RWDL 06-16 & SUPPORTING DOCUMENTATION Page 1 of 2 DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C C. Engineering Plans (All Application Packages): ® Per 15A NCAC 02U .0201(c)(1) or .0202(c), submit standard size and 11 x 17-inch plan sets that have been signed, sealed and dated by a North Carolina licensed Professional Engineer. At a minimum, the engineering plans shall include the following items: ® Table of contents. ® A general location map with at least two geographic references and a vicinity map. ® Plan and profile views of all pump stations and reclaimed water line extensions as well as the proximity of the reclaimed water line extensions to other utilities and natural features. ® Depict minimum separation distances required by 15A NCAC 02U .0403(h), (i), and 15A NCAC 02T .0305). ® Minimum cover in accordance with 15A NCAC 02T .0305(g)(4). ❑ Location and details of all pump stations. ® All labeling and color coding requirements per 15A NCAC 02U .0403. ® Plans shall represent a completed design and not be labeled with preliminary phrases (e.g., FOR REVIEW ONLY, NOT FOR CONSTRUCTION, etc.) that indicate they are anything other than final specifications. However, the plans may be labeled with the phrase: FINAL DESIGN - NOT RELEASED FOR CONSTRUCTION. D. Specifications (All Application Packages): ® Per 15A NCAC 02U .0201(c) or .0202(c), submit specifications that have been signed, sealed and dated by a North Carolina licensed Professional Engineer. At a minimum, the specifications shall include the following items: ® Specifications for standard equipment may be omitted for municipalities with approved standard specifications. Use of standard specifications must be noted on each page of the plans. ® Table of contents with each section/page numbered. ® Detailed specifications for each reclaimed water line and pump station (as applicable). ® Site Work (i.e., earthwork, clearing, grubbing, excavation, trenching, backfilling, compacting, fencing, seeding, etc.) ® Materials (i.e., concrete, masonry, steel, painting, method of construction, etc.) ® Electrical (i.e., control panels) ® All labeling and color coding requirements per 15A NCAC 02U .0403. ® Specifications shall represent a completed design and not be labeled with preliminary phrases (e.g., FOR REVIEW ONLY, NOT FOR CONSTRUCTION, etc.) that indicate they are anything other than final specifications. However, the specifications may be labeled with the phrase: FINAL DESIGN - NOT RELEASED FOR CONSTRUCTION. E. Engineering Calculations (All Application Packages): ® Per 15A NCAC 02U .0201(c) or .0202(c), submit calculations that have been signed, sealed and dated by a North Carolina licensed Professional Engineer. At a minimum, the calculations shall include the following items: ® Provide justification for the required pipe capacity, and details for how pipe sizes were determined. ® Minimum velocities to be maintained in the reclaimed water line. ❑ Friction/total dynamic head calculations and system curve analysis for each pump used. ❑ Pump selection information including pump curves, manufacturer's information, and recommended installation guidelines. ® Detailed specifications for each reclaimed water line and pump station (as applicable). ❑ Floatation calculations for any pump stations entirely or partially below grade. ❑ For connection to a pump station, submit an evaluation of the existing pump station's ability to handle peak flows. Provide calculations to detail how peak flows were determined. ❑ For connection to a force main, submit an evaluation of the existing force main based on peak flows to the proposed project and peak flows already tributary to the existing force main. ONE ORIGINAL AND TWO COPIES OF THE COMPLETED APPLICATION AND SUPPORTING DOCUMENTATION SHALL BE SUBMITTED TO: NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF WATER RESOURCES WATER QUALITY PERMITTING SECTION NON -DISCHARGE PERMITTING UNIT By U.S. Postal Service: 1617 MAIL SERVICE CENTER RALEIGH, NORTH CAROLINA 27699-1617 TELEPHONE NUMBER: (919) 807-6464 By Courier/Suecial Delivery: 512 N. SALISBURY STREET RALEIGH, NORTH CAROLINA 27604 FAX NUMBER: (919) 807-6496 INSTRUCTIONS FOR FORM: RWDL 06-16 & SUPPORTING DOCUMENTATION Page 2 of 2 DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C State of North Carolina DWR Department of Environmental Quality Division of Water Resources Division of Water Resources 15A NCAC 02U — RECLAIMED WATER SYSTEMS — DISTRIBUTION LINES FORM: RWDL 06-16 L CONTACT INFORMATION: 1. Applicant's name: Town of Holly Springs Mailing address: 128 South Main Street City: Holly Springs State: NC Zip: 27540- Telephone number: (2L9) 577-3150 Email Address: Kendra. ParrisW_HollySpringsnc.gov 2. Signature authority's name: Kendra Parrish (per 15A NCAC 02T .0106) Title: Executive Director of Utilities and Infrastructure 3. Consulting Engineer's name: Brandon McLamb License Number: 034374 Firm: Timmons Group Mailing address: 5410 Trinity Road, Suite 102 City: Ralei State: NC Zip: 27607- Telephone number: (2L9) 866-4935 Email Address: brandon.mclambktimmons.com IL DISTRIBUTION SYSTEM INFORMATION 1. Distribution system project name (name of subdivision, shopping center, etc.): Goodwin (Yield North) Infrastructure Phase I and II 2. Project county: Wake 3. USGS map name: New Hill 4. Owner of reclaimed water generating facility: Town of Holly Springs 5. Permit number of reclaimed water generating facility: W00032289 6. List the owner(s) of any intermediate reclaimed water lines if different from the applicant, or the generating facility. 7. Permit number for reclaimed water line immediately upstream: W00042791 8. Pipe diameter for reclaimed water line immediately upstream: 12 inch 9. Specify the proposed destination of the reclaimed water: Goodwin (Yield North) Development 10. Capacity of proposed distribution system: Refer to Technical Memorandum (by DMP) gallons per day 11. Explanation of how capacity was determined: Refer to Technical Memorandum (by DMP) III. DISTRIBUTION LINE DESIGN INFORMATION 1. Complete the table below for by providing the required information on the proposed distribution lines: Diameter (inches) Length (linear feet) Pipe Material High Elevation (ft Discharge Elevation ft 6 2,581 Purple PVC 319.40 333.35 +/- & 303.50 12 1,566 Purple PVC 342.58 342.58 +/- & 322.33 6 60 Ductile Iron 2. Station location of air release valves: N/A Note: Air release valves must be provided at all high points along the line where the elevation difference exceeds 10 ft. FORM: RWDL 06-16 Page 1 of 5 DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C III. DISTRIBUTION LINE DESIGN INFORMATION (Continued) 3. Complete the table below by providing the location of each design criteria in the specification and/or plans in accordance with 15A NCAC 02U .0403. Items that are not applicable shall be marked N/A. Design Criteria Page Number in Plans Page Number in Specifications Labeling on reclaimed water piping, valves, storage C4.0, C4.213 — C4.713 N/A facilities, and outlets Color coding on reclaimed water piping, valves, etc. N/A N/A Method of securing valves and outlet for operation by N/A N/A authorized personnel only Locking mechanism for hose bibs N/A N/A Cross connection control devices N/A N/A IV. SETBACKS (15A NCAC 02U .0701) 1. Provide the actual minimum distance (in feet) from any reclaimed water storage units and/or pump station within the distribution system to each item listed (distances greater than 500 feet may be marked N/A): Setback Parameter Pump stations within Reclaimed Water distribution system Storage Units Required Actual Required Actual Any private or public water supply source N/A N/A 100 N/A Any property line N/A N/A 50 N/A Any well with exception of monitoring wells 100 N/A 100 N/A Surface waters (streams — intermittent and perennial, 100 N/A 50 N/A perennial waterbodies, and wetlands) classified as SA Surface waters (streams — intermittent and perennial, 25 N/A 50 N/A perennial waterbodies, and wetlands) classified as SA 2. Do the pump stations and storage units comply with all setbacks found in the river basin rules (15A NCAC 2B .0200)? ❑ Yes or ❑ No ✓ If no, list non -compliant setbacks: 3. Are any setback waivers required in order to comply with 15A NCAC 02U .0701? ❑ Yes or ® No ✓ If yes, have these waivers been written, notarized, signed by all parties involved and recorded with the County Register of Deeds? ❑ Yes or ❑ No ✓ If yes, have the required Non -Discharge Wastewater System Waiver (FORM: NDWSW) fonns been included with this application package? ❑ Yes or ❑ No FORM: RWDL 06-16 Page 2 of 5 DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C V. SEPARATION DISTANCES 1. Provide the actual minimum separation distance (in feet) from the reclaimed water distribution system to each item listed in accordance with 15A NCAC 02U .0403(h), (i), and (1): Separation Parameter Horizontal Vertical Required Actual Required Actual Any water line (feet) 10 12,20 1.5 1.5 min Any well 50 N/A N/A N/A Sewer lines (reclaimed over sewer) 2 3.25, 6 1.5 1.5 min Final earth grade N/A 3 4.5 min 2. Are the separation requirements listed above met? ® Yes or ❑ No ✓ If No, has documentation been provided to show that piping and integrity testing procedures meet water main standards in accordance with 15A NCAC 18C? ❑ Yes or ❑ No Note: In no case shall reclaimed water lines be closer than 25 feet to a private well. VI. PUMP STATION INFORMATION IF MORE THAN ONE PUMP STATION, PROVIDE ADDITIONAL COPIES OF THIS PAGE AS NECESSARY. 1. Are there any reclaimed water pump stations proposed as part of the distribution system? ❑ Yes or ® No ✓ If no, then skip the remaining items in Section VI. 2. Complete the table below by providing the required information regarding the reclaimed water pump station(s) Pump Station Design Plan Sheet Number Specification Page Number Internal dimensions (L x W x H or (p x H) ft ft ft Volume gallons Inlet Elevation ft Outlet Elevation ft Number of pumps Pump capacity GPM Lead pump on elevation ft Lag pump on elevation ft Lead pump off elevation ft Lag pump off elevation ft High water elevation ft Audible/Visual high water alarm 3. What is the 100-year flood elevation? (ft) 4. Precautions to be taken to protect the pump station from flooding (ft) FORM: RWDL 06-16 Page 3 of 5 DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C VILSTORAGE TANK INFORMATION IF MORE THAN ONE STORAGE TANK PROVIDE ADDITIONAL COPIES OF THIS PAGE AS NECESSARY. 1. Are there any reclaimed water storage tanks proposed as part of the distribution system? ❑ Yes or ® No ✓ If no, then skip the remaining items in Section VII. 2. Complete the table below by providing the required information regarding the reclaimed water storage tank(s) Storage Tank Design Plan Sheet Number Specification Page Number Type of storage tank Select Internal dimensions (L x W x H or (p x H) ft ft ft Storage Volume gallons Inlet Elevation ft Outlet Elevation ft High water elevation ft Audible/Visual high water alarm 3. What measures will be taken to reduce the risk of overflow? FORM: RWDL 06-16 Page 4 of 5 DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C Professional Engineer's Certification: I, Brandon McLamb , attest that this application for Goodwin (Yield North) Infrastructure Phase I and II has been reviewed by me and is accurate, complete and consistent with the information supplied in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with this application package and its instructions as well as all applicable regulations and statutes. Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: oQa�oaaoouQoaao CAPO e o° ,p o '� �•40 1, SEAL 034374 ' ! �V°°fib Q LE74A5854E14484EF 5/6/2024 3:54 PM EDT Applicant's Certification (signing authority must be in compliance with 15A NCAC 02T .0106): I, Kendra D. Parrish, RE, Executive Director of Utilities & Infrastructure Services (signing authority name — PLEASE PRINT) (title) attest that this application for Goodwin (Yield North) Development (facility name) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that any discharge of wastewater from this non -discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. I further certify that the applicant or any affiliate has not been convicted of an environmental crime, has not abandoned a wastewater facility without proper closure, does not have an outstanding civil penalty where all appeals have been exhausted or abandoned, are compliant with any active compliance schedule, and do not have any overdue annual fees under Rule 15A NCAC 02U .0105. Note: In accordance with NC General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. DocuSigned by: 5/6/2024 � 1:50 PM PDT Signature: F"p Date: A3B6E125C87C4AE... FORM: RWDL 06-16 Page 5 of 5 DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C State of North Carolina I)WR Department of Environmental Quality Division of Water Resources 15A NCAC 02U — RECLAIMED WATER SYSTEMS — PROJECT INFORMATION Division of Water Resources INSTRUCTIONS FOR FORM: RWPI 06-16 & SUPPORTING DOCUMENTATION Please use the following instructions as a checklist in order to ensure all required items are submitted. Adherence to these instructions and checking the provided boxes will help produce a quicker review time and reduce the amount of additional information requested. Failure to submit all of the required items will lead to additional processing and review time for the permit application. For more information, visit the Water Quality Permitting Section Non -Discharge Permitting Unit website. General —This form is required for all projects involving the generation, utilization, and or distribution of reclaimed water. At least one of the following forms must also be included in the application package. However, multiple forms may be applicable. Unless otherwise noted, the Applicant shall submit one original and two copies of the application and supporting documentation. Please check the boxes below as appropriate to indicate which additional forms are included in the application package: ❑ Reclaimed Water Generation (FORM: RWG) — for wastewater treatment facilities producing reclaimed water. ❑ Non -Conjunctive Utilization (FORM: RWNC) — for reclaimed water utilization activities, when the reclaimed water utilization activity is required in order to meet the wastewater disposal needs of the facility. ❑ Conjunctive Utilization (FORM: RWCU) — for reclaimed water utilization activities, when the reclaimed water option is not necessary to meet the wastewater disposal needs of the facility and other wastewater utilization/disposal methods are available. ❑ Bulk Distribution (FORM: RWBD) — for distribution of reclaimed water in a bulk manner. ❑X Distribution Lines (FORM: RWDL) — for construction of reclaimed water distribution lines. ❑ Wetland Augmentation (FORM: RWWA) — for projects seeking to utilize reclaimed water for the purpose of wetland augmentation. ❑ Local Program Approval (FORM: RWLPA) — for projects seeking permitting delegation for reclaimed water users. A. Cover Letter (All Application Packages): X❑ List all items included in the application package, as well as a brief description of the requested permitting action. B. Application Fee (All New and Major Modification Application Packages): ❑X Submit a check, money order or electronic funds transfer made payable to: North Carolina Department of Environmental Quality (NCDEQ) according to the following fee schedules: ❑X STANDARD REVIEW — Submit the appropriate fee for all new and major modification applications as listed in the table below. Facility Classification New Permit I Major Modification' Major Generator/User (ADF > 10,000 gallons per day) $1,310 $395 Minor Generator/User (ADF < 10,000 gallons per day) $g 10 $245 Reclaimed Water Distribution Lines 7$600 N/A ' A major modification shall be defined as any permit modification that: increases the generating facility's average daily flow (ADF); increases the utilization area acreage; adds additional utilization areas not previously approved; or includes the addition of new treatment units/processes not previously permitted. There is no fee for minor permit modifications. INSTRUCTIONS FOR FORM: RWPI 06-16 & SUPPORTING DOCUMENTATION Page 1 of 2 DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C C. Reclaimed Water Project Information Form (FORM: RWPI 06-16) (All application packages): ❑X Submit the completed and appropriately executed Reclaimed Water Project Information (FORM: RWPI 06-16) form. Please do not make any unauthorized content changes to this form. RI The applicant name in Item I.1. shall be consistent with the applicant name on the plans, specifications, agreements, etc. ❑X The Applicant's Certification on Page 3 of this form shall be signed in accordance with 15A NCAC 02T .0106(b). The application must be signed by a principal executive officer of at least the level of vice-president or his authorized representative for a corporation; by a general partner for a partnership or limited partnership; by the proprietor for a sole proprietorship; and by either an executive officer, an elected official in the highest level of elected office, or other authorized employee for a municipal, state, or other public entity. An alternate person may be designated as the signing official if a delegation letter is provided from a person who meets the criteria in 15A NCAC 02T .0106(b). ❑ If this project is for a renewal without modification, use the Non -Discharge System Renewal (FORM: NDSR) application. There is no fee for permit renewal without modification. D. Existing Permit: (All Modification Packages): ❑ Submit the most recently issued existing permit. ❑ Provide a list of any items within the permit the Applicant would like the Division to address during the permit modification (i.e., compliance schedules, permit description, monitoring, permit conditions, etc.). ONE ORIGIANL AND TWO COPIES OF THE COMPLETED APPLICATION AND SUPPORTING DOCUMENTATION SHALL BE SUBMITTED TO: NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF WATER RESOURCES WATER QUALITY PERMITTING SECTION NON -DISCHARGE PERMITTING UNIT By U.S. Postal Service: 1617 MAIL SERVICE CENTER RALEIGH, NORTH CAROLINA 27699-1617 TELEPHONE NUMBER: (919) 807-6464 By Courier/Special Delivery: 512 N. SALISBURY STREET RALEIGH, NORTH CAROLINA 27604 FAX NUMBER: (919) 807-6496 INSTRUCTIONS FOR FORM: RWPI 06-16 & SUPPORTING DOCUMENTATION Page 2 of 2 DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C Division of Water Resources L GENERAL INFORMATION: State of North Carolina Department of Environmental Quality Division of Water Resources 15A NCAC 02U — RECLAIMED WATER SYSTEMS — PROJECT INFORMATION FORM: RWPI 06-16 1. Applicant's name: Town of Holly Springs Mailing address: 128 South Main Street City: Holly Springs State: NC Zip: 27540- Emily.Koncz&ollyspringsnc.gov Telephone number: (919) 577-3150 Email Address: Kendra.Parrishghollysspringsnc.gov 2. Signature authority's name: Kendra Parrish (per 15A NCAC 2U .0106) Title: Executive Director of Utilities and Infrastructure 3. Applicant type (check all that apply): ❑X Government ❑ Federal ❑ State ❑X Municipal ❑ County ❑ Individual ❑ Corporation ✓ For new permits, submit documentation that the company is registered for business with the NC Secretary of State. ❑ General Partnership ✓ For new permits, submit a copy of the certificate filed with the Register of Deeds in the county of business. ❑ Privately Owned Public Utility ✓ For new permits, submit a Certificate of Public Convenience and Necessity from the NC Utilities Commission, or a letter from the NC Utilities Commission's Water and Sewer Division Public Staff stating an application for a franchise has been received and that the service area is contiguous to an existing franchised area or that franchise approval is expected. ❑ Home Owners Association ✓ For new permits, submit a properly executed Operational Agreement (FORM: HOA); and proposed or approved Articles of Incorporation, Declarations and By-laws. ❑ Developer (where residential lots are to be sold) ✓ For new permits, submit a properly executed Operational Agreement (FORM: DEV) 4. Demonstration of historical consideration for permit approval: Has the Applicant or any parent, subsidiary or other affiliate exhibited the following? a. Has been convicted of environmental crimes under Federal law or G.S. 143-215.6B? ❑ Yes or ❑X No b. Has previously abandoned a wastewater treatment facility without properly closing that facility? ❑ Yes or ❑X No c. Has unpaid civil penalty where all appeals have been abandoned or exhausted? ❑ Yes or X❑ No d. Is non -compliant with an existing non -discharge permit, settlement agreement or order? ❑ Yes or X❑ No e. Has unpaid annual fees in accordance with 15A NCAC 02T .0105(e)(2)? ❑ Yes or X❑ No FORM: RWPI 06-16 Page 1 of 3 DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C II. PROJECT INFORMATION 1. Application type: Select (See Instruction B) Fee Submitted (See Instruction B) 2. For modifications, provide the existing permit number: WQ00 and most recent issuance date: 3. Provide a brief description of the activities proposed for pemutting:This proposed reclaimed water system will connect to an existing line along Woods Creek Road and serve the build -out of the Yield Noth development. The system will include 6" and 12" Purple PVC and 6" Ductile Iron pipes. 4. What is the status of the following associated permits and/or certifications ? (if not applicable, please mark as N/A) Permit/Certification Date Submitted Date Approved Permit/Certification No. Agency Reviewer Collection System (Q > 200,000 GPD) N/A Dam Safety N/A Erosion & Sedimentation Control Plan In Progress Pending Pending TOHS Nationwide 12 / Section404 Approved 12/15/2023 SAW-2023-01841on SAW-2023-01806 USACE Pretreatment Sewer System In Progress Pending Stormwater Management Plan In Progress Pending Pending Other: ✓ For any of the permits and certifications listed above that will directly impact the construction of the proposed reclaimed water project, please provide documentation of permit approval or final certification. Note: This application may be considered incomplete, or the resulting permit may be issued conditionally if a pending issuance of any of the related permits/certifications directly impacts the proposed facility. 5. Documentation of the presence or absence of threatened or endangered aquatic species at the project site utilizing information provided by the Department's Natural Heritage Program is required for construction of all new WWTP projects and/or non - conjunctive utilization sites, and for any project involving expansion of a WWTP and/or non -conjunctive utilization site in accordance with 15A NCAC 02T .0105(c)(10). Provide the location in application package where this documentation is located: ; or explain why this item is N/A. 6. Does this project utilize public monies or lands? ❑ Yes or 0 No ✓ If yes, was an Environmental Assessment required under 15A NCAC O1C? Yes ❑ No Include one of the following final environmental documents with this submittal: ❑ Finding of No Significant Impact, or ❑ Record of Decision Describe any mitigating factors from the Environmental Assessment that impact the design and/or construction of the reclaimed water project: 7. Is any portion of the proposed project (reclaimed water treatment units, storage units, distribution lines, or utilization areas) located within the 100 year flood plain? ❑ Yes or 0 No ✓ If yes, specify which portion(s) of the project are affected? ✓ If yes, has the Applicant submitted written documentation of compliance with § 143 Article 21 Part 6? ❑ Yes or ❑ No Documentation should consist of a letter from the local authority (i.e., county/municipality) stating that the project complies with any local floodplain ordinance that may apply. FORM: RWPI 06-16 Page 2 of 3 DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C Applicant's Certification (signing authority must be in compliance with 15A NCAC 02U .0106): I, Kendra D. Parrish, P.E. Executive Director of Utilities and Infrastructure Services (signing authority name — PLEASE PRINT) (title) attest that this application for Goodwin (Yield North) Phase I and II (facility name) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that any discharge of wastewater from this non -discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. I further certify that the applicant or any affiliate has not been convicted of an environmental crime, has not abandoned a wastewater facility without proper closure, does not have an outstanding civil penalty where all appeals have been exhausted or abandoned, are compliant with any active compliance schedule, and do not have any overdue annual fees under Rule 15A NCAC 02U .0105. Note: In accordance with NC General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. ned y: DocuSig Signature: F"�4 Date: 5/6/2024 1 1:50 PM PDT A3BK125CKC4AE... FORM: RWPI 06-16 Page 3 of 3 DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C CRESCENT C O M M U N I T I E S Developer Certification of Ownership and Dedication I, Elizabeth McMillan (developer/landowner), certify that I am the owner of the property upon which the proposed Goodwin THE YIELD North) Infrastructure Phase I & II _(subdivision/development) is planned as shown on # 22-MAS-03 & #23-DP-02 (TOHS Site Plan #), including all offsite easements required for the extension of public reclaimed water lines. Ownership of said property and easements is evidenced in the following recorded deeds: DB 019213 PG 00546-00549, DB 019213 PG 00550-00553 I hereby request that the Town of Holly Springs apply for a Reclaimed Water Distribution Line permit on my behalf for construction of the reclaimed water distribution lines. I certify that upon complete installation of the reclaimed water extensions and subsequent approval and acceptance by the Town of Holly Springs, the subject reclaimed waterlines and easements are hereby dedicated to the Town of Holly Springs. Signed: Date: CrescentCommunities.com Crescent Communities, LLC 601 S Tryon St, Suite 800, Charlotte, NC 28202 O: 980 3216000 Build Community. Better People's Lives. DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C DAMS - MARTIN • POWELL drn ENGINEERS & SURVEY 0 R S 10 T: 336-886-4821 • F: 336-886-4458 • License: F-0245 6415 Old Plank Road, High Point, NC 27265 • www.dmp-inc.com Technical Memorandum Date: January 23, 2023 .. ., Af Prepared For: Town of Holly Springs A2ZB 9oEscs7aFc9�s.-7 SEAS Reclaimed Water Modeling 024968 Godwin (Yield North) ' Prepared By: Michael Goliber, PE 01-21-2023 :' •� ••Q PI'„O� Project: DMP 220201 ' Background As requested by the Town of Holly Springs (Town), DMP has evaluated the feasibility of adding the proposed Godwin (Yield North) to the Reclaimed Water System. The proposed project is in the north limits of the Reclaimed Service Area and is along Woods Creek Road, slightly west of the Carolina Springs PUD. Model Setup DMP performed the evaluations utilizing the Town's reclaimed water system model in WaterCAD. The following setup was used for the modeling: • Reclaimed Model Setup — Tank Water Elev: 578' (normal low, down 7 ft) — WRF Pumps off — SFR Lots at Typical Demand (1.83 gpm/SFR due to average lot size being approximately 15,000 SF) (assumes 70% of SFR's are connected). — Sequiris: 550 gpm (includes 400 gpm cooling and 150 gpm irrigation) — WRF: 360 gpm (NPW uses + 200 gpm for RCW bulk filling) — Twelve Oaks Pond: 500 gpm — Ingenco: 53 gpm — Burt Tract: Full build out active and in service (412 gpm) — Hensley Tract: Full build out active and in service (214 gpm) — Twelve Oaks Phase 09: Full build out active and in service (Stephenson) (150 gpm) — Addison Subdivision: Full build out active and in service (Formerly Harris) (72 gpm) — New Hill Road Subdivision (52 GPM) — Carolina Springs PUD Phase 1—Areas 1-5 (296 GPM) — Carolina Springs PUD Phase 2 —Areas 6-8 (225 GPM) — Model Calculations: All modeling calculations were performed as a Steady State Model. Modeling as a Steady State Model provides for worst case demand condition, meaning that all demands in the model are active as part of the Scenario calculation. • Godwin (Yield North) Based on CAD drawings and PDF's provided to DMP by the Town of Holly Springs, the Godwin Development includes multiple sites for a business/industrial park. . The information provided to DMP was brought into the model as a backdrop. The reclaimed water line extensions and system nodes, with corresponding elevations, were then added to the model. Nodes within the project are estimated to be at an approximate elevation of 290 to 320 ft based on the information provided. DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C Technical Memorandum DMP 220058 Page 2 At this time the extensions of the Reclaimed Water System within the development were analyzed to provide irrigation demand to the proposed development. Modeling Results: Godwin was modeled as with 6" RCWL piping with new taps on the proposed 12" RCWL along Woods Creek Road, which will be extended as part of this project. The third area is extending lines in the previously approved Phase 1 area. The model also assumed that the developments proposed and approved prior, as outlined under Reclaimed Model Setup, are active and in service. Based on the above described model setup, one scenario was modeled and is described with results summarized as follows: Scenario 1: Base System (CS PUD Ph 2, all areas) This Scenario assumes full build out all Sub -phases in Phase 1 and all areas for Phase 2. — Existing 6" RCWL from New Hill Road to Ivy Arbor Way — New 12" RCWL installed from Ivy Arbor Way to Ingenco — Existing 12" RCWL to Twelve Oaks Phase 9 (Stephenson) — New 12" RCWL to serve Godwin — Results: Pressures are above 45 psi, which is the target system requirement minimum pressure. Feasible - Does meet the Project Objectives Summary For Godwin (Yield North), the model was setup as described above. One scenario was modeled and pressures within the Development are satisfactory and meet the requirements of the Town's RCW System. These results indicate that the proposed project meets the objectives of the system. One system component that should be monitored as part of the build -out for Godwin (Yield North) is the impact on the previously approved Twelve Oaks Phase 09. This system was designed to be installed with master meters, which require a 70 psi minimum, based on design information supplied to DMP at the time of review for Twelve Oaks Phase 09. With significant demands being placed on the system adjacent to and north of these master meters could potentially have impact on the operation of this system. Attached are the following documents: Exhibit: Active System Exhibit: Scenario 1 P: �2022�220201�Technical Memo�220201 Technical Memo for Godwin Yield North -FINAL 2023-01-23.docx DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C 1Jt1V 13 W 1VllitCl IiN W r V W r.LL ENGI N EERS & S U RVEYORS U P S JSO Q6lT 540-- Q q e7dmd 00j / $ilvet� 377R � o c_ - _ _ - - _ . i Ly • - _ - !o i Rey 2ol'Cre ek Pkw i� e'bite 55 . `oakville- 7 ...OIC y� Feltonville Crittenden Ln 9f a__________-__. V -------- _ -- Q H1an%, JaeiQ ._- to Greek ��t t' G\a t7 in Katha D! ITP t;teeµ lta y� 5 c a _ � J V - I Club - , tittye Branch . Oak. Easton St Arbat S\ CYPress _ - - - S _ otk5rnanship Way ?t' �y� weel Violet Dr Sp Arct'0 ^r - r tiE test Na Vinewood PI Fo Dr Legend �t°ey Trayesao� a E n r v,Y x- - - - - _Dtda le Cr x ci reservoirs e oro Wa Y c ,cf � p� ti t(gstn net ;t, O"04ei'Aleadows Ct �Ax V� om Dr v c Sr` o Six Target IIxFG. R = 3 ' Tank � O Food 2 . •.., ereets`S�C� 55 ,cLon c 1 ♦_ - sh Lucky Rib tA aDr u d c PC o u IS ACTIVE? " 403 N o �y j 3id St � N s 4 s ;; 357 rr s Holly Spri Pipes •� • v d _ Rib. 1 m Aid I tL` � m W Farp St • r, 2 R Dutchy E Ea rp $t Diamter • N Holly Springs � ^ r Broo ks St 4 • _ _ _ . _ V iiartenhne 3t 6 Heverr r S1e`tpp,P � a a � g ,C L51 GCB 't 10 • • • • sex �a 12 W EIm Ave ut .4748 � S'uron SI L'i 16 utl-y C,,,, , Sources: Esri, HERE, Garmin, Intermap, increment P Corp., GEBCO, USGS, FAO, NPS, NRCAN, GeoBase, IGN, KadaseI NL, Ordnance Survey, Esri Japan, METI, Esri China (Hong Kong), (c) OpenStreetMap contributors, and the GIS User Community Document Path: P:\2022\220201\GIS\Godwin - 1st Review Analysis Map -Active System Exhibit.mxd Hydraulic Analysis Map for Feet Godwin - 1st Review 1,500 750 0 1,500 3,000 4,500 Active System 1 inch = 1,907 feet DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C l/1 1 V 1 V — 1 V 11 11\ 1 11 \— 1- J V V LLL U"' ENGINEERS & SURVEYORS 0 Little While Oak Creek Legend Tank N SCENARIO 1 PRESSURES Range -13.600000 - 0.000000 0.000001 - 20.000000 20.000001 - 40.000000 40.000001 - 60.000000 60.000001 - 80.000000 80.000001 - 100.000000 J-3125 6 J-3124 N co X-1037 CO i J-1033 6, J-1038 377 R �hi�c O1 Rd F 1 J-3126 I rn =GODWIN (YIELD NORTH) J-1042 6 J-1043 J-1032 J- 022 ' J-1030 N J-1031 J-1027 CO- (e2 J- 0ign rn Sources: Esri, HERE, Garmin, Intermap, increment P Corp., GEBCO, USGS, FAO, NPS, NRCAN, GeoBase, IGN, Kadaster NL, Ordnance Survey, Esri Japan, METI, Esri China (Hong Kong), (c) OpenStreetMap contributors, and the GIS User Community Document Path: P:\2022\220201\GIS\Godwin - 1st Review Analysis Map - Scenario 1 Exhibit.mxd Hydraulic Analysis Map Feet for Godwin (Yield North) - 1st Review 500 250 0 500 1,000 1,500 Scenario 1 1 inch = 500 feet DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, ]R. Director Ms. Elizabeth McMillan CC Yield North LLC 601 South Tryon Street Suite 800 Charlotte, NC 282052 emcmillan@crescentcommunities.com NORTH CAROLINA Environmental Quality November 3, 2023 Subject: Revised 401 Water Quality Certification Pursuant to Section 401 of the Federal Clean Water Act for Proposed widening of Woods Creek Road in Holly Springs, Wake County. NCDWR Project No. 20221757 v.2 Dear Ms. McMillan: Attached hereto is a revision of Certification No. 6329 issued to CC Yield North LLC dated November 3, 2023. This approval is for the purpose and design described in your application. The plans and specifications for this project are incorporated by reference as part of this Water Quality Certification. If you change your project, you must notify the Division and you may be required to submit a new application package with the appropriate fee. If the property is sold, the new owner must be given a copy of this Certification and is responsible for complying with all conditions. [15A NCAC 02H .0507(d)(2)]. This Certification does not relieve the permittee of the responsibility to obtain all other required Federal, State, or Local approvals before proceeding with the project, including those required by, but not limited to, Sediment and Erosion Control, Non -Discharge, Water Supply Watershed, and Trout Buffer regulations. If we can be of further assistance, do not hesitate to contact us. Slncerel_v, Signed by: Eao0cu �� (, AfMNA, 4F4DD2F21EA846E... Richard E. Rogers, Director Division of Water Resources Attachments Cc: N. Carmela Stock, US Army Corps of Engineers (nichelle.c.stock@usace.army.mil) Kate Hefner, Timmons Group (kate.hefner@timmons.com) Kelly Williams, Division of Mitigation Services (kelly.williams@deq.nc.gov) File Copy North Carolina Department of Environmental Quality I Division of Water Resources 512 North Salisbury Street 1 1611 Mail Service Center I Raleigh, North Carolina 27699-1611 919.707.9000 DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C Revised 401 Water Quality Certification Pursuant to Section 401 of the Federal Clean Water Act with ADDITIONAL CONDITIONS THIS CERTIFICATION is issued in conformity with the requirements of Section 401 Public Laws 92-500 and 95-217 of the United States and subject to the North Carolina Division of Water Resources (NCDWR) Regulations in 15 NCAC 211 .0500. This certification authorizes CC Yield North LLC to impact 0.169 acres of jurisdictional wetlands and 224 linear feet of jurisdictional streams in Wake County. The project shall be constructed pursuant to the application dated received September 18, 2023. This revised approval replaces the one issued October 17, 2023. The authorized impacts are as described below: Stream Impacts in the Cape Fear River Basin Stream Permanent Fill Temporary Impact Permanent Fill in Riprap Temporary Total Site in Intermittent Intermittent Perennial Stream Stabilization to Impact to Stream Stream Stream (linear ft) (linear ft) Perennial Stream Perennial Stream Impact (linear ft) (linear ft) (linear ft) (linear ft) 2/4 0 0 132 10 20 162 (H) 7 52 10 0 0 0 62 (G) Total 52 10 132 10 20 224 Total Stream Impact for Project: 224 linear feet Revised Wetland Impacts in the Cape Fear River Basin Site Permanent Impact (ac) Temporary Impact (ac) Total Wetland Impact (ac) 1 0.008 0.009 0.017 3 0.032 0.012 0.044 5 0.002 0.003 0.005 6 0.047 0.005 0.052 8 0.031 0.024 0.055 Total 0.120 0.053 0.173 Total Wetland Impact for Project: 0.173 acres. The application provides adequate assurance that the discharge of fill material into the waters of the Cape Fear River Basin in conjunction with the proposed development will not result in a violation of applicable Water Quality Standards and discharge guidelines. Therefore, the State of North Carolina certifies that this activity will not violate the applicable portions of Sections 301, 302, 303, 306, 307 of PL 92-500 and PL 95-217 if conducted in accordance with the application and conditions hereinafter set forth. North Carolina Department of Environmental Quality I Division of Water Resources e,�--oREQ :�;\' 512 North Salisbury Street 1 1611 Mail Service Center I Raleigh, North Carolina 27699-1611 NORTH CAFiOLINA 919.707.9000 o.wmnem m �nro���w rwai� DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C This approval is only valid for the purpose and design that you submitted in your application dated received September 18, 2023 and revision received November 3, 2023. Should your project change, you are required to notify the NCDWR and submit a new application. If the property is sold, the new owner must be given a copy of this Certification and approval letter, and is thereby responsible for complying with all the conditions. If any additional wetland impacts, or stream impacts, for this project (now or in the future) exceed one acre or 150 linear feet, respectively, additional compensatory mitigation may be required as described in 15A NCAC 2H .0506 (h) (6) and (7). For this approval to remain valid, you are required to comply with all the conditions listed below. In addition, you should obtain all other federal, state or local permits before proceeding with your project including (but not limited to) Sediment and Erosion control, Coastal Stormwater, Non -discharge and Water Supply watershed regulations. This Certification shall expire on the same day as the expiration date of the corresponding Corps of Engineers Permit. This Water Quality Certification neither grants nor affirms any property right, license, or privilege in any lands or waters, or any right of use in any waters. This Water Quality Certification does not authorize any person to interfere with the riparian rights, littoral rights, or water use rights of any other person and does not create any prescriptive right or any right of priority regarding any usage of water. This Water Quality Certification shall not be interposed as a defense in any action respecting the determination of riparian or littoral rights or other rights to water use. No consumptive user is deemed by virtue of this Water Quality Certification to possess any prescriptive or other right of priority with respect to any other consumptive user regardless of the quantity of the withdrawal or the date on which the withdrawal was initiated or expanded. Upon the presentation of proper credentials, the Division may inspect the property. Conditions of Certification: 1. Compensatory mitigation for impacts to 0.120 acres of riparian wetlands in the Cape Far River Basin is required. We understand that you have chosen to perform compensatory mitigation for impacts to wetlands through the North Carolina Division of Mitigation Services (DMS) and that the DMS has agreed to implement the mitigation for the project. DMS has indicated in a letter dated October 30, 2023 that they will assume responsibility for satisfying the federal Clean Water Act compensatory mitigation requirements for the above -referenced project, in accordance with DMS's Mitigation Banking Instrument signed July 28, 2010. 2. Unless otherwise approved in this certification, placement of culverts and other structures in open waters and streams, shall be placed below the elevation of the streambed by one foot for all culverts with a diameter greater than 48 inches, and 20 percent of the culvert diameter for culverts having a diameter less than 48 inches, to allow low flow passage of water and aquatic life. Design and placement of culverts and other structures including temporary erosion control measures shall not be conducted in a manner that may result in dis-equilibrium of wetlands or streambeds or banks, adjacent to or upstream and down stream of the above structures. The applicant is required to provide evidence that the equilibrium is being maintained if requested in writing by the NCDWR. If this condition is unable to be met due to bedrock or other limiting features encountered during construction, please contact the NCDWR for guidance on how to proceed and to determine whether or not a permit modification will be required. [I5ANCAC 02H.0506(b)(2)] 2. Riprap shall not be placed in the streambed in a manner that precludes aquatic life passage. Bioengineering boulders or structures should be properly designed, sized and installed. [15A NCAC 02H.0506(b)(2)] 3. The stream channel shall be excavated no deeper than the natural bed material of the stream, to the maximum extent practicable. Efforts must be made to minimize impacts to the stream banks, as well as to vegetation responsible for maintaining the stream bank stability. Any applicable riparian buffer impact for access to stream channel shall be temporary and be revegetated with native riparian species. [15A NCAC 02H.0506(b)(2)] 4. Pipes and culverts used exclusively to maintain equilibrium in wetlands, where aquatic life passage is not a concern, shall not be buried. These pipes shall be installed at natural ground elevation. [I 5A NCAC 2H.0506(b)] North Carolina Department of Environmental Quality I Division of Water Resources e,�--oREQ :�;\' 512 North Salisbury Street 1 1611 Mail Service Center I Raleigh, North Carolina 27699-1611 NORTH CAFiOLINA 919.707.9000 o.wmnem m �nro���w rwai� DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C 5. Wetland areas impacted by temporary clearing shall be stabilized and reseeded with native wetland seed. [15A NCAC 2H.0506(b)] 6. If concrete is used during construction, a dry work area shall be maintained to prevent direct contact between curing concrete and stream water. Water that inadvertently contacts uncured concrete shall not be discharged to surface waters due to the potential for elevated pH and possible aquatic life and fish kills. [15A NCAC 02B.0200] 7. As stated in your application, the permittee shall receive approval of the Stormwater Management Plan by the appropriate locally delegated authority, prior to initiating any of the approved impacts in this Water Quality Certification. Permittee shall forward a copy of that approval to NCDWR to affirm this condition has been met. If sediment or other pollutants are found to be discharged from the stormwater outfalls, DWR may take enforcement action. DWR and permittee shall assess the damage to water quality standards and implement an appropriate action plan to address the impacts. The action plan shall provide an appropriate timeline for implementation as agreed upon by both DWR and the permittee. 8. For all streams being impacted due to site dewatering activities, the site shall be graded to its preconstruction contours and revegetated with appropriate native species. [15A NCAC 02H.0506(b)(2)] 9. During the construction of the project, no staging of equipment of any kind is permitted in waters of the U.S., or protected riparian buffers. [15A NCAC 02H.0506(b)(2)] 10. The dimension, pattern and profile of the stream above and below the crossing shall not be modified. Disturbed floodplains and streams shall be restored to natural geomorphic conditions. [15A NCAC 02H.0506(b)(2)] 11. The Permittee shall ensure that the final design drawings adhere to the permit and to the permit drawings submitted for approval. [ 15A NCAC 02H .0507 (c) and 15A NCAC 02H .0506 (b)(2) and (c)(2)] 12. All work in or adjacent to stream waters shall be conducted in a dry work area. Approved BMP measures such as sandbags, rock berms, cofferdams and other diversion structures shall be used to prevent excavation in flowing water. [15A NCAC 02H.0506(b)(3) and (c)(3)] 13. Heavy equipment shall be operated from the banks rather than in the stream channel in order to minimize sedimentation and reduce the introduction of other pollutants into the stream. [15A NCAC 02H.0506(b)(3)] 14. All mechanized equipment operated near surface waters must be regularly inspected and maintained to prevent contamination of stream waters from fuels, lubricants, hydraulic fluids, or other toxic materials. [15A NCAC 02H.0506(b)(3)] 15. No rock, sand or other materials shall be dredged from the stream channel except where authorized by this certification. [I5ANCAC 02H.0506(b)(3)] 16. Discharging hydroseed mixtures and washing out hydroseeders and other equipment in or adjacent to surface waters is prohibited. [15A NCAC 02H.0506(b)(3)] 17. The permittee and its authorized agents shall conduct its activities in a manner consistent with State water quality standards (including any requirements resulting from compliance with §303(d) of the Clean Water Act) and any other appropriate requirements of State and Federal law. If the NCDWR determines that such standards or laws are not being met (including the failure to sustain a designated or achieved use) or that State or federal law is being violated, or that further conditions are necessary to assure compliance, the NCDWR may reevaluate and modify this certification. [15A NCAC 02B.0200] 18. All fill slopes located in jurisdictional wetlands shall be placed at slopes no flatter than 3:1, unless otherwise authorized by this certification. [15A NCAC 02H.0506(b)(2)] 19. A copy of this Water Quality Certification shall be maintained on the construction site at all times. In addition, the Water Quality Certification and all subsequent modifications, if any, shall be maintained with on -site project manager. [15A NCAC 02H .0507(c) and 15A NCAC 02H .0506 (b)(2) and (c)(2)] North Carolina Department of Environmental Quality I Division of Water Resources e,�-#REQ :�;\' 512 North Salisbury Street 1 1611 Mail Service Center I Raleigh, North Carolina 27699-1611 NORTH CAFiOLINA 919.707.9000 o.wmnem m �nro���w rwai� DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C 20. The outside wetland or water boundary located within the construction corridor approved by this authorization, including all non-commercial borrow and waste sites associated with the project, shall be clearly marked by highly visible fencing prior to any land disturbing activities. Impacts to areas within the fencing are prohibited unless otherwise authorized by this certification. [15A NCAC 0211.0501 and .0502] 21. The issuance of this certification does not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (i.e. local, state, and federal) having jurisdiction, including but not limited to applicable buffer rules, stormwater management rules, soil erosion and sedimentation control requirements, etc. 22. The Permittee shall report any violations of this certification to the Division of Water Resources within 24 hours of discovery. [I 5A NCAC 02B.0506(b)(2)] 23. Upon completion of the project (including any impacts at associated borrow or waste sites), the permittee shall complete and return the enclosed "Certification of Completion Form" to notify the NCDWR when all work included in the 401 Certification has been completed. [I 5A NCAC 02H.0502(f)] 24. Native riparian vegetation must be reestablished in the riparian areas within the construction limits of the project by the end of the growing season following completion of construction. [15A NCAC 02B.0506(b)(2)] 25. There shall be no excavation from, or waste disposal into, jurisdictional wetlands or waters associated with this permit without appropriate modification. Should waste or borrow sites, or access roads to waste or borrow sites, be located in wetlands or streams, compensatory mitigation will be required since that is a direct impact from road construction activities. [15A NCAC 02H.0506(b)(3) and (c)(3)] 26. Erosion and sediment control practices must be in full compliance with all specifications governing the proper design, installation and operation and maintenance of such Best Management Practices in order to protect surface waters standards [15A NCAC 02H.0506(b)(3) and (c)(3)]: a. The erosion and sediment control measures for the project must be designed, installed, operated, and maintained in accordance with the most recent version of the North Carolina Sediment and Erosion Control Planning and Design Manual. b. The design, installation, operation, and maintenance of the sediment and erosion control measures must be such that they equal, or exceed, the requirements specified in the most recent version of the North Carolina Sediment and Erosion Control Manual. The devices shall be maintained on all construction sites, borrow sites, and waste pile (spoil) projects, including contractor -owned or leased borrow pits associated with the project. c. For borrow pit sites, the erosion and sediment control measures must be designed, installed, operated, and maintained in accordance with the most recent version of the North Carolina Surface Mining Manual. d. The reclamation measures and implementation must comply with the reclamation in accordance with the requirements of the Sedimentation Pollution Control Act. 27. Sediment and erosion control measures shall not be placed in wetlands or surface waters, or within 5 feet of the top of bank, without prior approval from DWR. [I 5A NCAC 02H.0506(b)(3) and (c)(3)] 28. When applicable, all construction activities shall be performed and maintained in full compliance with G.S. Chapter 113A Article 4 (Sediment and Pollution Control Act of 1973). Regardless of applicability of the Sediment and Pollution Control Act, all projects shall incorporate appropriate Best Management Practices for the control of sediment and erosion so that no violations of state water quality standards, statutes, or rules occur. [15A NCAC 02H .0506{b)(3) and (c)(3) and 15A NCAC 02B .0200] North Carolina Department of Environmental Quality I Division of Water Resources e,�--oREQ :�;` 512 North Salisbury Street 1 1611 Mail Service Center I Raleigh, North Carolina 27699-1611 NORTH CAFiOLINA 919.707.9000 o.wmnem m �nro���w rwai� DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C 29. Design, installation, operation, and maintenance of all sediment and erosion control measures shall be equal to or exceed the requirements specified in the most recent version of the North Carolina Sediment and Erosion Control Manual, or for linear transportation projects, the NCDOT Sediment and Erosion Control Manual. All devices shall be maintained on all construction sites, borrow sites, and waste pile (spoil) sites, including contractor -owned or leased borrow pits associated with the project. Sufficient materials required for stabilization and/or repair of erosion control measures and stormwater routing and treatment shall be on site at all times. For borrow pit sites, the erosion and sediment control measures shall be designed, installed, operated, and maintained in accordance with the most recent version of the North Carolina Surface Mining Manual. Reclamation measures and implementation shall comply with the reclamation in accordance with the requirements of the Sedimentation Pollution Control Act and the Mining Act of 1971. If the project occurs in waters or watersheds classified as Primary Nursery Areas (PNAs), SA, Trout, WS-1, WS-11, High Quality Waters (HQW), Outstanding Resource Waters (ORW), or 303(d) Impaired Waters, then the sedimentation and erosion control designs shall comply with the requirements set forth in 15A NCAC 04B .0124, Design Standards in Sensitive Watershed. [15A NCAC 02H.0506(b)(3) and (c)(3); GC 4135] This approval and its conditions are final and binding unless contested [G.S. 143-215.5]. Please be aware that impacting waters without first applying for and securing the issuance of a 401 Water Quality Certification violates Title 15A of the North Carolina Administrative Code (NCAC) 2H .0500. Title 15A NCAC 2H .0500 requires certifications pursuant to Section 401 of the Clean Water Act whenever construction or operation of facilities will result in a discharge into navigable waters, including wetlands, as described in 33 Code of Federal Regulations (CFR) Part 323. It also states any person desiring issuance of the State certification or coverage under a general certification required by Section 401 of the Federal Water Pollution Control Act shall file with the Director of the North Carolina Division of Water Quality. Pursuant to G.S. 143-215.6A, these violations and any future violations are subject to a civil penalty assessment of up to a maximum of $25,000.00 per day for each violation. This Certification can be contested as provided in Chapter 150B of the North Carolina General Statutes by filing a Petition for a Contested Case Hearing (Petition) with the North Carolina Office of Administrative Hearings (OAH) within sixty (60) calendar days. Requirements for fling a Petition are set forth in Chapter 150B of the North Carolina General Statutes and Title 26 of the North Carolina Administrative Code. Additional information regarding requirements for filing a Petition and Petition forms may be accessed at http://www.ncoah.com/ or by calling the OAH Clerk's Office at (919) 431-3000. A party fling a Petition must serve a copy of the Petition on: William F. Lane, General Counsel Department of Environmental Quality 1601 Mail Service Center Raleigh, NC 27699-1601 If the party fling the Petition is not the permittee, then the party must also serve the recipient of the Certification in accordance with N.C.G.S 15013-23(a). This the 3rd day of November 2023 DIVISION OF WATER RESOURCES IDocuSigned by: Qwll (A AfMat1, 4F4DD2F21EA846F Richard E. Rogers, Jr, Director WQC No. 6329 North Carolina Department of Environmental Quality I Division of Water Resources e,�--oREQ :�;` 512 North Salisbury Street 1 1611 Mail Service Center I Raleigh, North Carolina 27699-1611 NORTH CAFiOLINA 919.707.9000 o.wmnem m n,nro���w rwai� DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C NCDWR Project No.: County: Applicant: Project Name: Date of Issuance of 401 Water Quality Certification: Certificate of Completion Upon completion of all work approved within the 401 Water Quality Certification or applicable Buffer Rules, and any subsequent modifications, the applicant is required to return this certificate to the 401 Transportation Permitting Unit, North Carolina Division of Water Resources, 1617 Mail Service Center, Raleigh, NC, 27699-1617. This form may be returned to NCDWR by the applicant, the applicant's authorized agent, or the project engineer. It is not necessary to send certificates from all of these. Applicant's Certification I, , hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance and intent of the 401 Water Quality Certification and Buffer Rules, the approved plans and specifications, and other supporting materials. Signature: Agent's Certification Date: I, , hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance and intent of the 401 Water Quality Certification and Buffer Rules, the approved plans and specifications, and other supporting materials. Signature: Engineer's Certification Partial Final Date: I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically, weekly, full time) the construction of the project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance and intent of the 401 Water Quality Certification and Buffer Rules, the approved plans and specifications, and other supporting materials. Signature Date Registration No. North Carolina Department of Environmental Quality I Division of Water Resources e,�--oREQ :�;` 512 North Salisbury Street 1 1611 Mail Service Center I Raleigh, North Carolina 27699-1611 NORTH CAFiOLINA 919.707.9000 o.wmnem m �nro���w rwai� DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C SECTION 11.00 RECLAIMED WATER DISTRIBUTION SYSTEM TABLE OF CONTENTS 11.00 GENERAL 11.01 RECLAIMED WATER DISTRIBUTION PIPE A.. Design B. Materials C. Installation 1.1.02 VALVES AND APPURTENANCES A. Valves B. Appurtenances 11.03 RECLAIMED WATER SERVICE TAPS A. Design B. Materials 11.04 RECLAIMED WATER IRRIGATION SYSTEMS A. General B. Designs C. Street Crossing D. Hose Bibs E. Rain Sensors 11.05 TESTING AND INSPECTION A. General B. Testing C. Inspection D. Cross Connection Control ,�{►iiiilY���f` 1.1.06 REPAIR OF RECLAIMED WATER SYSTEM 2015 ED&CS 1 t-1 Supp ii 9 Dec. 2023 DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C 11.00 GENERAL A. All aspects of the design and construction of any portion of the reclaimed water distribution system shall, at a minimum, meet the requirements of the North Carolina Department of Environmental Quality (NCDEQ) Division of Water Resources (DWR). Requirements presented in the Town of Holly Springs Standard Specifications hereunder that are more restrictive or go above and beyond the requirements of DWR are required by the Town of Holly Springs. B. All Reclaimed water systems must be designed per North Carolina Administrative Code Title 15A (15A NCAC) — Environmental Quality, Subchapters 02T, 02U, and 18C latest revisions, the governing regulations. C. Extensions of the existing reclaimed water distribution system must adhere to any and all Policy Statements and/or Master Plans pertaining to the reclaimed water distribution system and receive prior approval from the Executive Director of Utilities and Infrastructure Services, prior to consideration. D. Reclaimed water main extensions may require a detailed hydraulic report, signed and sealed by a North Carolina Professional Engineer, be submitted to the Executive Director of Utilities and Infrastructure Services and receive approval prior to construction drawing submittal. E. All utility extension permits must be obtained prior to construction. Refer to the Town Code of Ordinances Section 16 for further requirements. F. Reclaimed water shall be utilized and distributed in accordance with 15A NCAC 02U Sections .0500 through 0.0700. G. Any reclaimed water that leaves the reclaimed water distribution system other than by means of a properly permitted use must be disposed of into the Town of Holly Springs sanitary sewer system. This includes any reclaimed water line flushing, and/or line breaks unless otherwise allowed by NCDEQ rules. Deminimus runoff from distribution air relief valves and blow -off is deemed permitted per NCDEQ rules. Any reclaimed water that is not a properly permitted use or sent to a sanitary sewer must be reported and handled as if it were a wastewater spill. 11.01 RECLAIMED WATER DISTRIBUTION PIPE All new irrigation systems located within the Town's reclaimed service area desiring to obtain water service for such system from the Town must connect to the reclaimed water system, if reclaimed water is available to the property. Design must be in accordance with Chapter 16 Article IV of the Holly Springs Town Code of Ordinances. These areas are shown on the Reclaimed Water Distribution Service Area Map located on the Town's web site. 2015 ED&CS 11-2 Supp # 9 Dec. 2023 DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C A. DESIGN 1. Location: Reclaimed water lines shall be extended along the roadway to the adjacent property line. All public reclaimed water mains shall be located within dedicated right of way or dedicated easements with a minimum width of 20 feet. See Section 2.10 for allowable landscape plantings within a Town of Holly Springs easement. 2. Sizing: Reclaimed water mains shall be sized in accordance with good design procedures to provide adequate pressures throughout the system or as directed by the Executive Director of Utilities and Infrastructure Services. The minimum pipe size for reclaimed water mains shall be 4 inches in accordance with the reclaim hydraulic model. 3. Installation: All utility extension permits must be obtained prior to construction utilizing appropriate application forms from NCDEQ and/or the town. All reclaimed water mains shall have a minimum cover of 4 feet measured from the top of the pipe to the finished grade. When reclaimed water mains are installed along a roadway which does not have curb and gutter, the reclaimed water main shall be installed at sufficient depth to prevent conflict with future road improvements or vertical alignment changes. 4. Relation to Potable Water Mains and Other Utilities a) Reclaimed water distribution lines shall be located at least 10-feet horizontally from any water line, unless local conditions or barriers prevent a 10-foot lateral separation. If these separation distances cannot be met, the piping and integrity testing procedures shall meet water main standards in accordance with 15A NCAC 18C. Reclaimed water distribution lines shall meet the separation distances to sewer lines in accordance with 15A NCAC 02T .0305. b) Reclaimed water mains should only cross sanitary sewer mains or potable water mains at an approximate 90 degree angle. d) The minimum separation between reclaimed water mains and storm sewer mains must be either 5 feet horizontal or 2 feet horizontal with a vertical separation of 24 inches unless otherwise approved by the Executive Director of Utilities and Infrastructure Services. Where storm sewers cross reclaimed water with a vertical separation of less than 24 inches the segment of reclaimed water pipe shall be ductile iron pipe at least one whole pipe length from the crossing point with joints equivalent to water main standards. 2015 ED&CS 11-3 Supp # 9 Dec. 2023 DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C e) Where reclaim water main crosses under storm sewer main with a vertical separation less than 24 inches then reclaim water must be ductile iron minimum of 10 feet each side of crossing and properly marked as reclaim. f) Where sanitary sewer crosses reclaimed mains, a vertical separation of 18 inches must be maintained. g) Reclaimed water distribution lines shall not be less than 50 ft from a well unless the piping and integrity testing procedures meet water main standards, but in no case shall they be less than 25 feet from a private well or 50 ft from a public well. 5. Identification of Reclaimed Pipes a. General: All new distribution piping in the reclaimed water system, including service lines, valves and other appurtenances should either be colored purple (Pantone 522 or similar) and embossed or be integrally stamped/marked "CAUTION: RECLAIMED WATER — DO NOT DRINK," or be installed with a purple identification tape, and a purple polyethylene vinyl wrap. b) Polyethylene Wrap: Buried ductile iron pipe and fittings shall be wrapped with a purple colored polyethylene membrane conforming to ANSI A21.5, and installed in accordance with AWWA C105. The polyethylene sheets shall be 8 mils thick, minimum, and be colored purple (Pantone 522 or similar). c) Tracer Wire: Tracer wire shall be installed on all reclaimed piping. Tracer wire shall be installed as shown in the Details. Approved Wire Connectors shall be used to attach wire together. d) Identification Tape: Identification tape should be prepared with white or black printing on a purple field (Pantone 522 or similar) having the words "CAUTION: RECLAIMED WATER — DO NOT DRINK." The overall width of the tape should be at least 3 inches. ii. Identification tape should be installed on the top of the distribution piping longitudinally and should be centered over the pipe. The identification should be continuous in its coverage on the pipe and should be fastened to each pipe length no more than 10 feet apart. Tape attached to sections of pipe before they are placed in the trench should 2015 ED&CS 11-4 Supp # 9 Dec. 2023 DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C have flaps sufficient for continuous coverage. Other satisfactory means of securing the tape during backfill of the trench may be used if suitable for the work, as determined by the Executive Director of Utilities and Infrastructure Services. iii. The identification tape differentiating the reclaimed water piping from other utility lines should be consistent throughout the service area. e) Signage: i. The public shall be notified of the use of reclaimed water. ii. Advisory signs shall be posted around reclaimed water irrigation activities in public areas, adjacent to ponds used to store reclaimed water in public areas, and at decorative water features that use reclaimed water. iii. All advisory signs should be colored purple (Pantone 522 or similar), should read "CAUTION: RECLAIMED WATER — DO NOT DRINK," The sign shall reference the TOHS Utilities and Infrastructure Services Department. Additionally, signage shall provide emergency number of 919-577-1090 and the Town's web site. B. MATERIALS 1. Material: All reclaimed water main distribution pipe 4" thru 12" diameter shall be C900 PVC pipe. All reclaimed water main distribution pipe greater than 12" diameter shall be C905 PVC. Ductile Iron Pipe shall only be used in special cases and with the Executive Director of Utilities and Infrastructure Services approval. New manufacturers must submit requests for approval to the Executive Director of Utilities and Infrastructure Services. Additional information such as catalogs, list of installations in the area or material samples may be required. A written response will be mailed to the applicant accepting or rejecting the product within 90 days of the receipt of all necessary information. 2. Ductile Iron Pipe: a) This material shall only be used for reclaimed water lines with Executive Director of Utilities and Infrastructure Services' approval. b) Buried ductile iron pipe and fittings shall be wrapped with a purple colored polyethylene membrane conforming to ANSI A21.5, and installed in accordance with AWWA C105. The polyethylene sheets shall be 8 mils thick, minimum, and be colored purple (Pantone 522 or similar). c) Ductile iron pipe shall be designed and manufactured in accordance with AWWA C150 and C151. The minimum required pressure ratings for ductile iron pipe installed at a Type 2 laying condition are tabulated below. For all 2015 ED&CS 11-5 Supp # 9 Dec. 2023 DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C other installations other than specified, the laying condition or the minimum pressure class rating shall be increased in accordance with AWWA C151. Pipe Diameter Depth of Cover Pressure Class 6-8 -inch 3-20 feet 350 psi 10-12 -inch 3-14 feet 350 psi 14-20 -inch 3-10 feet 250 psi 24-64 -inch 3 - 8 feet 150 psi d) Pipe joints shall be of the push -on type as per AWWA C111. Pipe lining shall be cement mortar with a seal coat of bituminous material in accordance with AWWA C104. Galvanized steel pipe will not be allowed as a material for reclaimed water mains or reclaimed water service lines. 3. PVC Pipe: a) PVC pipe (4" to 12") shall be designed and manufactured in accordance with AWWA C900. PVC pipe larger than 12" shall be designed and manufactured in accordance with AWWA C905. The PVC pipe shall be made of virgin PVC resin that provides chemical and physical properties that meet or exceed cell class 12454-B as defined in ASTM D 1784. All PVC pipe shall be supplied in standard laying lengths of 20 feet. Pipe shall be furnished in factory packaged units, with each joint plainly marked with the manufacturer's name, pressure class, size, etc. PVC pipe shall have integral wall, bell and spigot joints fabricated with elastomeric gaskets that meet or exceed the performance requirements of ASTM D3139 and F477. Fittings used on PVC pipe shall be AWWA C153 compact ductile iron fittings. b) All PVC pipe supplied for reclaimed water applications shall be color coded purple (Pantone 522 or similar) as required by 15A NCAC 02U — Reclaimed Water). c) Furnish pipe for the following minimum pressure classes as indicated. Diameter 4"-12", C900 Pressure Class 150, SDR 18 Diameter 14" and larger, C905 Pressure Class 165, DR18. 4. Steel Encasement for reclaimed water pipes are required for the following Street Classifications to avoid traffic disruption in the future: • Controlled Access Highway For carrier pipes that employ cathodic protection anticorrosion systems, the carrier and casing pipes shall be effectively insulated from one another. Carrier and casing shall be cathodically protected as a unit. See Section 5.03 Boring and Jacking for more casing pipe size requirements. 2015 ED&CS 11-6 Supp # 9 Dec. 2023 DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C C. INSTALLATION Ductile iron pipe shall be installed in accordance with the requirements of AWWA C600 and the Ductile Iron Pipe Handbook published by the Ductile Iron Pipe Research Association. At a minimum, all ductile iron pipe shall be installed at a Type 2 laying condition as specified by AWWA C600. 2. PVC pipe shall be installed in accordance with AWWA C605. At a minimum, all PVC pipe shall be installed at a Type 3 laying condition as specified by AWWA C605. 3. Materials at all times shall be handled with mechanical equipment or in such a manner to protect them from damage. At no time shall pipe and fittings be dropped or pushed into ditches. 4. Pipe and fitting interiors shall be protected from foreign matter and shall be inspected for damage and defects prior to installation. In the event foreign matter is present in pipe and fittings, it shall be removed before installation. Open ends of pipe shall be plugged or capped when pipe laying is not in progress. All pipes shall be in nominal lengths of eighteen or twenty feet and shall be installed with at least 48 inches of cover below the finished subgrade. Pipe shall be laid on true lines as directed by the Executive Director of Utilities and Infrastructure Services. Trenches shall be sufficiently wide to adjust the alignment. Bell holes shall be dug at each joint to permit proper joint assembly. The pipe shall be laid and adjusted so that the alignment with the next succeeding joint will be centered in the j oint and the entire pipeline will be in continuous alignment both horizontally and vertically. Pipe joints shall be fitted so that a thoroughly watertight joint will result. All joints will be made in conformance with the manufacturer's recommendations for the type of joint selected. All transition joints between different types of pipe shall be made with transition couplings approved on shop drawings showing the complete assembly to scale. 6. Prior to beginning construction, the Contractor shall contact local utility companies and verify the location of existing utilities. The Contractor shall be completely and solely responsible for locating all existing buried utilities inside the construction zone before beginning excavation. The Contractor shall be solely responsible for scheduling and coordinating the utility location work. When an existing utility is in conflict with construction, it shall be exposed prior to beginning construction to prevent damage to the existing utility. 7. Valves in the existing Town of Holly Springs water system shall not be operated without a minimum notice of 24 hours to the Executive Director of Utilities and Infrastructure Services and the Director of Public Utilities. The Contractor shall 2015 ED&CS 11-7 Supp # 9 Dec. 2023 DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C operate valves only in accordance with Town of Holly Springs Engineering Design and Construction Standards. 11.02 VALVES AND APPURTENANCES A. VALVES General a) Valves shall be installed on all branches from feeder reclaimed water mains according to the following schedule: 4 valves at crosses; 3 valves at tees. When a loop section of reclaimed water line is connected back into the feeder reclaimed water main within a distance of 200 feet or less, only one valve will be required in the feeder reclaimed main. Reclaimed water main extensions or mains extending at a project phase line shall include a valve and one additional standard length of pipe with a cap and a temporary blow -off assembly. b) Where no reclaimed waterline intersections are existing, amain line valve shall be installed at every 100 feet per 1-inch diameter main up to a distance of 1000 feet between valves. In addition, the Town of Holly Springs reserves the right to require additional isolation valves where necessary for efficient operation and maintenance. c) Valves shall be properly located, operable and at the correct elevation. All valves and reducers shall be rodded to the tee or cross if one is located within 10 feet as shown in the Details. If reducers cannot be rodded, concrete blocking or other restraining methods will be required. The maximum depth of the valve nut shall be 5 feet. When valve extension kits are used, they must be manufactured by the same company which manufactured the valve. 2. Combination Air Valves a) Combination air valves shall be installed at all high points of reclaimed water lines 12" inches in diameter or larger and at other locations as directed by the Town of Holly Springs. The reclaimed water main shall be installed at a grade which will allow the air to migrate to a high point where the air can be released through an air valve. A minimum pipe slope of 1 foot in 500 feet should be maintained. The valve shall have a minimum two (2) inch NPT inlet and 200- PSIG working pressure. Combination air valves shall be sized by the Engineer and approved by the Town of Holly Springs. b) Combination air valves shall be of the single housing style that combines the operation of both an air/vacuum and air release valve. The valve must meet the requirements of AWWA C512 and be installed in accordance with the Details. 2015 ED&CS 11-8 Supp # 9 Dec. 2023 DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C c) Manholes installed for the combination air valves shall meet all requirements of Section 7.00. Crate Valves a) Gate valves 2 inches and greater shall meet all requirements of AWWA C500 for a working pressure of 200 psi. All gate valves shall be mechanical joint with iron body, bronze mounting double disc parallel seat type with a non -rising stem and open left with a double O-ring seal. b) Gate valves, up to and including 12 inches, shall be installed in a vertical position. c) Gate Valves 16 inches and larger must be approved by the Executive Director of Utilities and Infrastructure Services. They may be installed horizontally and equipped with bevel gears, grease case, rollers, tracks scrapers, and a bypass located on the side of the body (fully revolving disc valves shall not require rollers), or vertically and be equipped with spur gears enclosed in a grease case and with a bypass located on the side of the body. In either case, the roller and scraper operators shall be installed in a manhole that meets all requirements of Section 7.00. 4. Resilient Seat Wedge Gate Valves: Resilient seat wedge gate valves shall be manufactured in accordance with AWWA C509 for a working pressure of 200 psi. All shall be mechanical joint with iron body, open left with a non -rising stem and two O-ring stem seals. All ferrous surfaces, both inside and outside, shall be protected by a fusion -bonded epoxy coating. Butterfly Valves: Butterfly Valves may be installed in reclaimed water mains 24 inches or greater with the permission of the Executive Director of Utilities and Infrastructure Services. All butterfly valves shall meet the requirements of AWWA C504 with mechanical joints, 2 inch open left operating nut. Valves installed on reclaimed waterlines at depths greater than 6' (measured to top of pipe) shall be installed in a manhole (see Section 7.00) as shown in the Details. Valves designated by the Town of Holly Springs to potentially have a remote actuator shall be installed in a manhole (see Section 7.00) as shown in the Details. 6. Valve Boxes a) Valve boxes shall be cast iron, screw or telescopic type, with a 5-inch opening. Valve box ring adjustments will not be allowed. All valve boxes shall be furnished with an approved operating key which shall allow operation by authorized personnel only. b) Valve box covers shall be square in shape (NOT round) and shall be designed for AASHTO H-20 truck loadings. All valve box covers shall be of non- 2015 ED&CS 11-9 Supp # 9 Dec. 2023 DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C interchangeable shape with potable water covers, and cast on the top surface with a recognizable inscription indicating "Reclaimed Water". All valve box covers shall be painted purple (Pantone 522 or similar). c) The valve box shall be centered over the wrench nut and seated on compacted backfill without touching the valve assembly. All valve boxes shall be encased in a trowel finished 2' x 2' x 6" pad of 3000-psi concrete beneath the asphalt with the cover flush with the top of the pavement or flush with the finished grade. Precast concrete valve box encasements may not be used for valve box encasement outside of paved areas. The maximum depth of the valve nut shall be 5 feet. When valve extension kits are used, they must be manufactured by the same company that manufactured the valve. B. APPURTENANCES 1. Pipe Fittings: Pipe fittings shall be castor ductile iron designed and manufactured as per AWWA C110. Sizes of fittings up to and including 12 inches shall be designed for an internal pressure of 250 psi, and larger size fittings shall be designed for an internal pressure of 150 psi. Compact ductile iron mechanical joint fittings designed and manufactured as per AWWA C111 are also acceptable. Joints for fittings shall be mechanical and lined with cement mortar with a seal coat of bituminous material, all in accordance with AWWA C104. 2. Blowoffs a) Blowoffs installed at the end of cul-de-sacs shall be a minimum of 2 inches. Blowoffs installed on transmission and distribution mains shall be a minimum of 2 inches. Where there is not sufficient pressure to thoroughly flush the system, a larger blowoff will be required. b) Blowoff assemblies shall be constructed as shown in the Details. The valves shall be gate type with a non -rising stem and a 2-inch operating nut, O-ring seals and screwed ends. A full-size valve is required on mains that are planned to be extended. c) Blowoffs shall be directed in a non -erosive manner to a stabilized grassed area at least 50 ft. from a jurisdictional feature or directed into the closest sanitary sewer manhole. Blowoffs installed at the end of cul-de-sacs should be tied into a sanitary sewer manhole where available. 3. Thrust Restraint: Reaction blocking for all fittings or components subject to hydrostatic thrust shall be securely anchored by the use of concrete thrust blocks poured in place or restrained joint piping as described below a. Concrete thrust blocks shall be poured in place with reaction areas as shown in the Details. No concrete shall interfere with the removal of fittings. Material for reaction blocking shall be 3000 psi concrete. A minimum 4 mil plastic shall 2015 ED&CS 11-10 Supp # 9 Dec. 2023 DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C cover the fitting to ensure that no concrete will interfere with removal of the fitting. b. PVC Bell Joint Restraint - All PVC bell joints shall be restrained for both C900 and C905 PVC pipe. The bell joint restraint shall consist of either an approved restrained PVC joint provided by the same manufacturer of the PVC pipe or an approved bell joint restraint harness. All bell joint restraint harness assemblies shall be made of ductile iron pipe (DIP), coated with a manufacturer applied epoxy coating or polyester powder coating, including stainless steel bolts, nuts and rods. The bell joint restraint harness shall be manufacturer approved for use with PVC pipe and rated for at least 200-psi with a 3:1 safety factor. c. All valves and fittings shall be restrained to C900 or C905 pipe with an approved wedge action retainer gland or other approved restraining method. All DIP fittings for reclaimed water use shall be identified by purple painting or wrapping with polyethylene wrap (Pantone 522 or similar). Alternative restraining methods and mechanical joint restraints may be used upon approval by the Executive Director of Utilities and Infrastructure Services. 11.03 RECLAIMED WATER SERVICE TAPS A. DESIGN Individual reclaimed water services, and multiple branch services, shall be provided from the reclaimed water main to each reclaimed water meter for single customer locations in accordance with the Details. All connections shall be made by wet taps. Service connections shall be made perpendicular to the reclaimed water main and shall run straight to the reclaimed water meter. 2. All reclaimed water meter boxes and vaults shall be located at the edge of the serviced lot's right of way or easement. Reclaimed water meter boxes shall not be placed in streets, sidewalks, parking areas or obstructed by fencing or buildings. Exceptions to these conditions will be at the direction of the Executive Director of Utilities and Infrastructure Services. 3. Service taps to existing reclaimed water mains shall be made by the Town of Holly Springs. Service taps to new reclaimed water mains shall be made by the Contractor in accordance with the Specifications. 4. Water meters shall be sized based on applicant water budget calculations using the approved method. Water meter size shall be determined from the following table; or as otherwise specified by the Executive Director of Utilities and Infrastructure Services. Multiple branch services size shall be determined by the designer. 2015 ED&CS 11-11 Supp # 9 Dec. 2023 DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C METER SIZING GUIDE Meter Size Flow Range inches GPM 3/4" PD 0 - 20 I" PD 20-50 11/2"PD 50- 100 2" C 100 - 200 3" C 200 - 400 4" C 400 - 600 PD = Positive Displacement T = Turbine (may be required on a case -by -case basis) C = Compound (must be sized on a case -by -case basis) 5. Service taps greater than 2 inches shall be made by a Contractor of the Developer. B. MATERIALS Direct taps shall not be allowed on C900 or C905 PVC mains. The maximum allowable size for saddle taps is 2". All taps larger than 2-inches shall be installed by inline fittings or tapping sleeves. All tapping of C900 or C905 PVC mains shall be implemented with shell type cutting tools classified for use with PVC pipe that retains the coupon cut while penetrating the pipe wall, use of twist drill bits and auger bits shall be prohibited. The maximum size of direct taps without a fitting, tapping sleeve or saddle for ductile iron mains shall be as follows: Main Size inches Tap Size inches 4" main 3/4" to 6" main 1" to 8" main 1 1/4" to 10" main 1 1/2" to 12" main 2" to 2. Tapping Sleeves: Tapping Sleeves shall be made of either cast iron or stainless steel. The sleeve shall be two-piece with mechanical joint to the main line and flanged to the tapping valve. Cast iron shall meet AWWA C110 2015 ED&CS 11-12 Supp # 9 Dec. 2023 DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C specifications. Stainless steel shall meet AWWA C223 specifications. All sleeves shall require full circumferential gasket. All tapping sleeves shall be manufactured and approved for installation on the specific main line pipe material (DIP, C900, C905). 3. Tapping Saddles: Tapping Saddles shall be used on reclaimed water mains 16 inches and larger. Saddles shall be made of ductile iron providing a factor of safety of 2.5 with a working pressure of 250 psi. Saddles shall be equipped with an AWWA C110 flange connection on the branch. Sealing gaskets shall be O-ring type, high quality molded rubber having an approximate 70 durometer hardness, placed into a groove on the curved surface of the saddles. Straps shall be alloy steel. The maximum size saddle outlet for each size of pipe to be tapped shall be as follows: Size pipe to be tapped Maximum size Saddle Outlet 16" 8" 18" 8" 20' 10" 24" and larger 12" 4. Corporation Stops: Corporation Stops shall be ball type, made of brass and complete with a compression or flared coupling and AWWA Standard threads as per AWWA C800. Taps shall be located at 10:00 or 2:00 o'clock on the circumference of the pipe. Service taps shall be staggered alternating from one side of the reclaimed water main to the other and at least 12 inches apart. The taps must be a minimum of 24 inches apart if they are on the same side of the pipe. No burned taps will be allowed and each corporation stop will be wrapped with Teflon tape for ductile iron pipe reclaimed water mains. No tapping shall be made where rodding is placed. 5. Service Saddles: Service saddles shall be bronze body (85-5-5 waterworks brass) and double strap for taps with silicon bronze nuts conforming to ASTM A98 and factory installed grade 60 rubber gaskets. Service saddles shall be approved by the manufacturer for use on C900/C905 PVC mains. 6. Service Tubing: Copper service tubing shall be type K soft copper tubing per ASTM B88. No union shall be used in the installation of the service connection of 100-feet or less. The longest available length of service line shall be used with no unions (e.g. for 3/4 inch, only 1 union will be allowed for each 100 foot section). Unions shall be made with flare or compression type couplings. Copper service tubing shall be installed reclaimed locating tape, spirally wrapped from the tap through the setter. 7. Coppersetters for 3/4 and 1-inch Reclaimed Water Services: All 3/4 and 1-inch reclaimed water services shall be installed with coppersetters as shown in the 2015 ED&CS 11-13 Supp # 9 Dec. 2023 DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C Details. All coppersetters shall be as manufactured by Mueller or Ford at the dimensions shown in the Details. All coppersetters shall be installed with a lockable angle ball valve assembly and outlet angle check valve on all size setters. Coppersetters shall be installed with flare fittings and all coppersetter assemblies shall be provided as shown in the Details with galvanized brace pipes for additional stability. All installations shall provide the coppersetter properly aligned with the meter box reader lid such that the meter is clearly visible below the reader lid. 8. Meter Boxes for 3/4-inch services: 3/4-inch meter boxes shall be light weight polymer concrete as shown in the Details. Meter boxes for 3/4-inch reclaimed water services shall provide a cover opening of 11 X 18 inches and boxes shall measure at least 18-inches in depth. Meter boxes and covers shall be rated for "heavy duty" uses, such as alleys, driveways, parking lots, etc. Standard meter box covers shall not bolt down to the box. The box interior walls and covers shall be consistently color - coded purple (Pantone 522 or similar). All covers shall include a 4 X 6 inch cast iron reader lid with the words "RECLAIMED WATER — DO NOT DRINK" cast into the lid in 1-1/2" tall lettering. The Town of Holly Springs reserves the right to require all meter box covers to include brackets and housing for "ITRON" compatible transponders for automated meter reading systems. All meter boxes and covers shall be installed as shown in the Details. 9. Meter boxes for 1-inch services: 1-inch meter boxes shall be lightweight polymer concrete as shown in the Details. Meter boxes for 1-inch reclaimed water services shall provide a cover opening of 11 X 18 inches and boxes shall measure at least 18-inch in depth. Meter boxes and covers shall be rated for "heavy duty" uses, such as alleys, driveways, parking lots, etc. Standard meter box covers shall not bolt down to the box. The box interior walls and covers shall be consistently color - coded purple (Pantone 522 or similar). All covers shall include a 4 X 6 inch cast iron reader lid with the words "RECLAIMED WATER — DO NOT DRINK" cast into the lid in 11/2" tall lettering. The Town of Holly Springs reserves the right to require all meter box covers to include brackets and housing for "ITRON" compatible transponders for automated meter reading systems. All meter boxes and covers shall be installed as shown in the Details. 10. Meter boxes for 1'/z and 2-inch services: 1 1/2" and 2" meter boxes shall be light weight polymer concrete as indicated in the Standard Details. All meter box interiors and covers shall be consistently color -coded purple (Pantone 522 or similar). Covers shall be marked on the top surface with a recognizable inscription indicating "RECLAIMED WATER — DO NOT DRINK" in 1-1/2" tall lettering. Piping for 1 1/2 and 2 inch reclaimed water meters shall be constructed from brass and copper tubing and shall be equipped with angled check valve outlets and by-pass flanged valve or by-pass flanged ball valve inlets. The box shall have an open bottom to allow drainage through stone. 2015 ED&CS 11-14 Supp # 9 Dec. 2023 DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C 11. Meter Vaults: Meter vaults and access doors within street right of way shall meet HS-20 loading requirements and shall be located outside of travel areas. The access double doors shall be aluminum with a flush drop lift handle, stainless steel hinges and bolts, a stainless steel slam lock, an automatic hold open arm, and compression springs to allow for easy opening. Covers shall be marked on the top surface with recognizable inscription indicating "Reclaimed Water -Do Not Drink" 12. Reclaimed Water Meters: Reclaimed water meters for 3/4" to 2" services will be provided by the Town of Holly Springs. Larger meters shall be provided by the developer as directed by the Executive Director of Utilities and Infrastructure Services. Reclaimed water meters, registers and covers shall be purple (Pantone 522 or similar). 11.04 RECLAIMED WATER IRRIGATION SYSTEMS A. GENERAL All reclaimed water irrigation systems within public street right of way require an encroachment agreement from the Town of Holly Springs or NCDOT prior to installation. Plans designating the location, size, material, and depth shall be submitted with the agreement application to the Engineering Department. Pipe material for the irrigation mainline proposed to be used within the public right of way shall be Schedule 40 PVC or greater. All pipe, fittings, and appurtenances shall be purple (Pantone 522 or similar). A minimum depth of 2 feet of cover shall be provided. A soil evaluation is necessary in order to determine the loading rate for irrigation permits. All development within the reclaim service area will need to complete an independent soil evaluation prior to submitting a reclaim irrigation permit. All reclaimed water irrigation systems are required to secure permits from the Code Enforcement Department and the Utilities and Infrastructure Services prior to installation and shall be inspected after installation. A separate meter is required for irrigation systems. For single family irrigation design, a CID, PE, or LA is required to develop the plan. For non -single family irrigation system designs, a PE must develop the plan. Impoundments for reclaimed water storage for large scale irrigation systems or aesthetic/decorative water features shall be designed in accordance with 15A NCAC 02U — Reclaimed Water. Service lines from mainline tap to the meter are installed and identified per the Town of Holly Spring's Standard Details. There shall be no direct cross -connection between potable and reclaimed water supplies. 2015 ED&CS 11-15 Supp # 9 Dec. 2023 DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C B. DESIGNS Sprinklers chosen and located to maintain the following setbacks from the irrigation area to the following features: 1.) 25 feet from surface waters [perennial and intermittent streams, wetlands] not classified as tidal salt waters or high -quality water (SA). 2.) 100 feet from surface waters [perennial and intermittent streams, wetlands] classified as tidal salt waters or high -quality water (SA). 3.) 100 feet from any water supply well (not including monitoring wells). 4.) Sprinklers located on a steep slope have check valves installed on all the heads on that irrigation zone. 5.) No mainlines or valves shall be allowed within the utility/devil strip. Laterals will be allowed and shall be placed within 1 ft of sidewalk. 6.) The zoning of the irrigation system must allow that plants with different water requirements (such as grass and shrubs) are on separate zones. In addition, the irrigation design should consider the different microclimates found in most landscapes (such as north facing grass areas vs. south facing grass areas) and separate those microclimates into zones. These zoning practices may add slightly to the installation cost of an irrigation system, but can have a dramatic effect on system efficiency. 7.Guidelines on pressure at the head/emitter: Spray Heads 20 to 35 psi; gear rotors 60 psi or less; impact rotors 60 psi or less; drip emitters 40 psi or less. 8.Large commercial systems which have the potential to place undue burdens (demand or pressure requirements) on the Town of Holly Springs' public reclaimed distribution system must include on -site storage and/or pumping facilities. This determination will be made by the Executive Director of Utilities and Infrastructure Services. Design, operation, and maintenance of such on -site facilities shall be the sole responsibility of the applicant. These additional facilities must be designed in accordance with 15A NCAC 02U — Reclaimed Water. 9.Rain sensors must be installed to reduce the likelihood of overwatering. Rain sensors are required to remain in service at all times to prevent overwatering and/or ponding of reclaimed water. C. STREET CROSSING 2015 ED&CS 11-16 Supp # 9 Dec. 2023 DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C All irrigation line street crossings shall be contained within a ductile iron or steel casing pipe. The Town of Holly Springs may, in some instances, permit irrigation systems installed in the medians of Town -maintained roadways. These systems must also have french drains installed behind the curb and gutter and piped to a storm drainage collection system. These systems shall be allowed only when some permanent mechanism is established for the private perpetual maintenance of the system(s). D. HOSE BIDS Hose bibs are not permitted for the reclaimed water system. E. RAIN SENSORS Rain sensors must be installed to reduce the likelihood of overwatering. Rain sensor must remain in operation to prevent ponding or runoff. 11.05 TESTING AND INSPECTION A. GENERAL 1. All reclaimed water used in testing and inspection must be disposed of properly as described in Section 11.00. 2. All materials must be approved by the Inspector prior to installation. Materials rejected by the Town of Holly Springs' Inspector shall be immediately removed from the job site. 3. Under no circumstance shall any waterline system valve be operated without prior approval by the Construction Inspector. Damage to Town of Holly Springs infrastructure resulting from illegal operation of valves shall be the responsibility of the Contractor. In addition, the Contractor shall be subject to a fine for operating a valve without prior approval. 4. The Contractor shall furnish all materials, labor, equipment, and shall pay for the water used to perform all testing and inspections to the satisfaction of the Construction Inspector. The Contractor shall obtain a Blowoff Permit from the Town of Holly Springs Engineering Department for use when blowing off reclaimed water mains. 5. Reclaimed water service taps shall not be made until after all main testing is completed, and bacteriological testing is satisfactory. B. TESTING 1. Hydrostatic Testing 2015 ED&CS 11-17 Supp # 9 Dec. 2023 DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C a) All valves in the Town of Holly Springs reclaimed water system shall be operated by the Town of Holly Springs. A section of reclaimed water main which is to be hydrostatically tested shall be slowly filled with water at a rate which will allow complete evacuation of air from the line. Hand pumps shall not be used for the pressure testing of reclaimed water mains. Taps used for testing purposes shall be removed after testing. The corporation stops shall be removed and a threaded tapered plug shall be installed on the line. When approved by the Town of Holly Springs, the Contractor may utilize potable water or reclaimed water via an approved hydrant meter and RPZ assembly for testing and disinfection of new reclaimed mains which are not physically connected to a live reclaimed water supply. Once reclaimed water has been introduced into the system no direct connection to potable water will be allowed and an approved air gap assembly must be used. b) Any measured leakage not within the allowable limits as specified in the following table shall require repair of the reclaimed water main and additional testing until the standards are met. For pipe sizes other than those shown, the Contractor shall test within the allowable leakage amounts as specified by AWWA C600-99. All visible leaks shall be repaired regardless of the amount of leakage. Pipe Size (Inches) 4 6 8 12 16 20 24 2. Chlorination Allowable Leakage at 200-psi (Gal./Hr. per 1000 feet of pipe) 0.43 0.64 0.85 1.28 1.70 2.12 2.55 a) All additions or replacements to the reclaimed water system shall be chlorinated before being placed in service under the supervision of the Town of Holly Springs' Inspector in the following manner: i. Taps shall be made at the control valve at the upstream end of the reclaimed water main and at all extremities of the line including valves. ii. A solution of water containing 70% HTH available chlorine shall be introduced into the reclaimed water main by regulated pumping at the control -valve tap. The solution shall be of such a concentration that the reclaimed water main shall have a uniform concentration of 50 ppm total 2015 ED&CS 11-18 Supp # 9 Dec. 2023 DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C chlorine immediately after chlorination. The chart below shows the required quantity of 70% HTH compound to be contained in solution in each 1,000 feet section of line to produce the desired concentration of 50 ppm. Pipe Size Pounds High Test Hypochlorite (70%) (inches) per 1000 feet of line 6 1.76 8 3.12 10 4.84 12 7.00 14 9.52 16 12.44 20 19.52 24 28.00 iii. The HTH Solution shall be circulated in the reclaimed water main by opening the control valve and systematically manipulating blowoffs and taps at the reclaimed water main extremities. All reclaimed water leaving the system during this test must be disposed of through either an approved use or sent to the sanitary sewer. The HTH solution must be pumped in at a constant rate for each discharge rate so a uniform concentration will be produced in reclaimed water mains. iv. HTH solution shall remain in reclaimed water mains for no less than 24 hours or as directed by the Town of Holly Springs' Inspector. v. Extreme care shall be exercised at all times to prevent the HTH solution from entering existing reclaimed water mains. 3. Bacteriological Sampling a) Free residual chlorine after 24 hours shall be at least 10 ppm or the Town of Holly Springs' Inspector will require that the lines be re -chlorinated. b) Flushing of reclaimed water mains may proceed after 24 hours, provided the free residual chlorine analysis is satisfactory. Reclaimed water leaving the system because of line flushing must be returned to a sanitary sewer. Flushing shall be continued until an orthotolidine check (or other method approved by the Town of Holly Springs) shows that the reclaimed water mains contain only the normal chlorine residual. Samples for bacteriological analysis shall be collected by the Town of Holly Springs' Inspector 24 hours after flushing is completed. The Contractor shall furnish the sample bottles, the testing agency and such help as may be required to secure these samples. The Contractor shall also submit the test results to the Town of Holly Springs' Development Inspector. 2015 ED&CS 11-19 Supp # 9 Dec. 2023 DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C c) If test results are unsatisfactory, the Contractor shall immediately rechlorinate reclaimed water mains and proceed with such measures as are necessary to properly sterilize those reclaimed water mains. d) The new reclaimed water system shall be valved off from the existing reclaimed water system until a satisfactory bacteriological sample has been obtained and the Town of Holly Springs' Inspector has authorized the use of the new reclaimed water system. C. INSPECTIONS Approved plans and permit must be issued and available on -site before any inspections are performed. 2. Underground Inspections — before work is covered up/back filled: a) Inspection of main line tap and piping to meter box; b) Inspection of underground piping from meter box through irrigation system from meter to end of system to insure compliance with approved plan and standards; 3. Final Inspection a) Includes inspection of the location of all heads, type of heads, spacing of heads and throw pattern of each head and correct pressure; b) Testing the system to ensure compliance with approved plans and Town of Holly Springs Ordinance; 4. A map of the approved valve and head layout shall be provided by the Contractor to the property owner and a copy placed near or with the timer. All zones shall be clearly labeled in the timer cabinet. 6. Responsible entity shall be listed on inner door of timer (for emergency contact purposes). 7. Verification of required setbacks (reclaimed water). D. CROSS CONNECTION CONTROL 1. Backflow prevention on potable water services serving any property that is also served with reclaimed water is required in accordance with the Federal Safe Drinking Water Act. At all locations where reclaimed water service is provided, the public potable water supply shall be protected by installation of an approved backflow prevention device. 2015 ED&CS 11-20 Supp # 9 Dec. 2023 DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C a. For Residential Properties: prior to receiving reclaimed water service, a dual check valve shall be installed on each residential customer's potable water meter in order to protect the potable water system. A Reduced Pressure Principal (RPZ) type backflow prevention device downstream of the potable water meter is not required when the only reclaimed water use is landscape irrigation. b. For Multi -family complexes and commercial properties: master -metered potable water service and master -metered reclaimed water service shall be required to install a Reduced Pressure Principal (RPZ) type backflow prevention device downstream of the master potable water meter. 11.06 REPAIR OF RECLAIMED WATER SYSTEM Reclaimed water that leaves the system due to a leak or break in the system must be reported and handled as if it were a wastewater spill. A. Reclaimed Water Main Line Repairs 1. Joint leaks of Cast Iron Pipe, Ductile Iron Pipe, and PVC pipe shall be repaired by use of a bell joint leak repair clamp as manufactured by Rockwell, or other approved equal. 2. Line Breaks or Punctures shall be repaired by a full circle repair clamp as manufactured by Rockwell, Mueller, or other approved material. 3. Line Splits or Blow Outs shall be repaired by replacing the damaged section with ductile iron pipe with a cast iron coupling at each end. The following cast pipe couplings shall be used for each pipe material indicated: a) Ductile Iron Pipe - Rockwell 431 cast coupling or other approved equal. b) PVC Pipe — Rockwell 411 cast coupling or other approved equal. B. Reclaimed Water Service Line Repairs 1. A reclaimed water service line severed between the reclaimed water main and the reclaimed water meter shall be repaired using new type K copper tubing and bronze or brass 3-piece flared unions. 2. A corporation stop pulled out of a reclaimed PVC pipe water main shall have a new service saddle and a new corporation stop installed on the reclaimed water main. 3. A corporation stop pulled out of a ductile iron pipe shall have a full circle repair clamp placed over the old tap hole. A new tap shall be made and a new corporation stop installed on the reclaimed water main. 2015 ED&CS 11-21 Supp # 9 Dec. 2023 DocuSign Envelope ID: 5A63DB29-F694-436F-8932-950E1917959C END OF SECTION 11.00 2015 ED&CS 11-22 Supp # 9 Dec. 2023 DocuSign Certificate Of Completion Envelope Id: 5A63DB29F694436F893295OE1917959C Status: Completed Subject: Complete with DocuSign: 42196 Goodwin Yield N. Ph 1 and 2 Reclaim Permit application.doc, 20221... Source Envelope: Document Pages: 50 Signatures: 4 Envelope Originator: Certificate Pages: 5 Initials: 5 Emily Koncz AutoNav: Enabled PO Box 8 Envelopeld Stamping: Enabled Holly Springs, NC 27540 Time Zone: (UTC-05:00) Eastern Time (US & Canada) emily.koncz@hollyspringsnc.gov IP Address: 76.218.234.175 Record Tracking Status: Original 4/26/2024 10:26:02 AM Signer Events Rachel Jones rachel.jones@hollyspringsnc.gov Utility Engineer Security Level: Email, Account Authentication (None) Electronic Record and Signature Disclosure: Accepted: 5/17/2021 2:39:29 PM ID:126bfa6d-c99c-4b40-be28-00aa263b860b Company Name: Town of Holly Springs Brandon McLamb brandon.mclamb@timmons.com Senior Project Manager Security Level: Email, Account Authentication (None) Electronic Record and Signature Disclosure: Accepted: 5/6/2024 3:54:46 PM ID: a2edcaba-36ce-4059-9f23-41b150a976d1 Company Name: Town of Holly Springs Catherine Jacobs catherine.jacobs@hollyspringsnc.gov Engineering Manager Security Level: Email, Account Authentication (None) Electronic Record and Signature Disclosure: Accepted: 5/6/2024 4:10:38 PM ID:ed407e2l-a46a-4180-b3dc-8b645f8a5a7f Company Name: Town of Holly Springs Kendra Parrish kendra.parrish@hollyspringsnc.gov Director of Utilities & Infrastructure Holly Springs Security Level: Email, Account Authentication (None) Electronic Record and Signature Disclosure: Holder: Emily Koncz emily.koncz@hollyspringsnc.gov Signature lrT,-,s Signature Adoption: Pre -selected Style Using IPAddress: 64.98.121.61 �"by: [DocuSigned VcUn a oln 1tiL4awt� 74A5854E14484EF... Signature Adoption: Pre -selected Style Using IPAddress: 104.15.28.241 EDS Signature Adoption: Pre -selected Style Using IPAddress: 204.84.166.2 EDo,uS!gn,d by: 4A3MEI�25C87C4AE . Signature Adoption: Pre -selected Style Using IPAddress: 76.38.84.134 Signed using mobile Location: DocuSign Timestamp Sent: 4/26/2024 10:50:52 AM Resent: 4/29/2024 12:05:16 PM Resent: 5/1/2024 9:19:57 AM Viewed: 5/3/2024 9:36:26 AM Signed: 5/3/2024 9:38:35 AM Sent: 5/3/2024 9:38:38 AM Resent: 5/6/2024 8:03:18 AM Viewed: 5/6/2024 3:54:09 PM Signed: 5/6/2024 3:54:24 PM Sent: 5/6/2024 3:54:28 PM Viewed: 5/6/2024 4:09:32 PM Signed: 5/6/2024 4:10:19 PM Sent: 5/6/2024 4:10:23 PM Viewed: 5/6/2024 4:10:53 PM Signed: 5/6/2024 4:50:43 PM Signer Events Signature Timestamp Accepted: 5/6/2024 4:50:30 PM ID: efcf34b4-f68c-42da-b7c1-0565cff95e99 Company Name: Town of Holly Springs In Person Signer Events Signature Timestamp Editor Delivery Events Status Timestamp Agent Delivery Events Status Timestamp Intermediary Delivery Events Status Timestamp Certified Delivery Events Status Timestamp Carbon Copy Events Status Timestamp Witness Events Signature Timestamp Notary Events Signature Timestamp Envelope Summary Events Status Timestamps Envelope Sent Hashed/Encrypted 4/26/2024 10:50:52 AM Envelope Updated Security Checked 4/29/2024 12:04:59 PM Envelope Updated Security Checked 4/29/2024 12:04:59 PM Certified Delivered Security Checked 5/6/2024 4:10:53 PM Signing Complete Security Checked 5/6/2024 4:50:43 PM Completed Security Checked 5/6/2024 4:50:43 PM Payment Events Status Timestamps Electronic Record and Signature Disclosure Electronic Record and Signature Disclosure created on: 11/12/2020 9:42:57 PM Parties agreed to: Rachel Jones, Brandon McLamb, Catherine Jacobs, Kendra Parrish ELECTRONIC RECORD AND SIGNATURE DISCLOSURE From time to time, Town of Holly Springs (we, us or Company) may be required by law to provide to you certain written notices or disclosures. Described below are the terms and conditions for providing to you such notices and disclosures electronically through the DocuSign system. Please read the information below carefully and thoroughly, and if you can access this information electronically to your satisfaction and agree to this Electronic Record and Signature Disclosure (ERSD), please confirm your agreement by selecting the check -box next to `I agree to use electronic records and signatures' before clicking `CONTINUE' within the DocuSign system. Getting paper copies At any time, you may request from us a paper copy of any record provided or made available electronically to you by us. You will have the ability to download and print documents we send to you through the DocuSign system during and immediately after the signing session and, if you elect to create a DocuSign account, you may access the documents for a limited period of time (usually 30 days) after such documents are first sent to you. After such time, if you wish for us to send you paper copies of any such documents from our office to you, you will be charged a $0.00 per -page fee. You may request delivery of such paper copies from us by following the procedure described below. Withdrawing your consent If you decide to receive notices and disclosures from us electronically, you may at any time change your mind and tell us that thereafter you want to receive required notices and disclosures only in paper format. How you must inform us of your decision to receive future notices and disclosure in paper format and withdraw your consent to receive notices and disclosures electronically is described below. Consequences of changing your mind If you elect to receive required notices and disclosures only in paper format, it will slow the speed at which we can complete certain steps in transactions with you and delivering services to you because we will need first to send the required notices or disclosures to you in paper format, and then wait until we receive back from you your acknowledgment of your receipt of such paper notices or disclosures. Further, you will no longer be able to use the DocuSign system to receive required notices and consents electronically from us or to sign electronically documents from us. All notices and disclosures will be sent to you electronically Unless you tell us otherwise in accordance with the procedures described herein, we will provide electronically to you through the DocuSign system all required notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to you during the course of our relationship with you. To reduce the chance of you inadvertently not receiving any notice or disclosure, we prefer to provide all of the required notices and disclosures to you by the same method and to the same address that you have given us. Thus, you can receive all the disclosures and notices electronically or in paper format through the paper mail delivery system. If you do not agree with this process, please let us know as described below. Please also see the paragraph immediately above that describes the consequences of your electing not to receive delivery of the notices and disclosures electronically from us. How to contact Town of Holly Springs: You may contact us to let us know of your changes as to how we may contact you electronically, to request paper copies of certain information from us, and to withdraw your prior consent to receive notices and disclosures electronically as follows: To contact us by email send messages to: jeff.wilson@hollyspringsnc.us To advise Town of Holly Springs of your new email address To let us know of a change in your email address where we should send notices and disclosures electronically to you, you must send an email message to us at jeff.wilson@hollyspringsnc.us and in the body of such request you must state: your previous email address, your new email address. We do not require any other information from you to change your email address. If you created a DocuSign account, you may update it with your new email address through your account preferences. To request paper copies from Town of Holly Springs To request delivery from us of paper copies of the notices and disclosures previously provided by us to you electronically, you must send us an email to jeff.wilson@hollyspringsnc.us and in the body of such request you must state your email address, full name, mailing address, and telephone number. We will bill you for any fees at that time, if any. To withdraw your consent with Town of Holly Springs To inform us that you no longer wish to receive future notices and disclosures in electronic format you may: i. decline to sign a document from within your signing session, and on the subsequent page, select the check -box indicating you wish to withdraw your consent, or you may; ii. send us an email to jeff.wilson@hollyspringsnc.us and in the body of such request you must state your email, full name, mailing address, and telephone number. We do not need any other information from you to withdraw consent.. The consequences of your withdrawing consent for online documents will be that transactions may take a longer time to process.. Required hardware and software The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found here: hitps://sU]2ort.docusign.com/guides/signer-guide- si fining -system -requirements. Acknowledging your access and consent to receive and sign documents electronically To confirm to us that you can access this information electronically, which will be similar to other electronic notices and disclosures that we will provide to you, please confirm that you have read this ERSD, and (i) that you are able to print on paper or electronically save this ERSD for your future reference and access; or (ii) that you are able to email this ERSD to an email address where you will be able to print on paper or save it for your future reference and access. Further, if you consent to receiving notices and disclosures exclusively in electronic format as described herein, then select the check -box next to `I agree to use electronic records and signatures' before clicking `CONTINUE' within the DocuSign system. By selecting the check -box next to `I agree to use electronic records and signatures', you confirm that: You can access and read this Electronic Record and Signature Disclosure; and You can print on paper this Electronic Record and Signature Disclosure, or save or send this Electronic Record and Disclosure to a location where you can print it, for future reference and access; and Until or unless you notify Town of Holly Springs as described above, you consent to receive exclusively through electronic means all notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to you by Town of Holly Springs during the course of your relationship with Town of Holly Springs. Crescent Communities. LLC NCDEQDWR NCDEQ - DIV. OF WATER RESOUR. ` DATE INVOICE NO DESCRIPTION . - INVOICEAMOUNT -' DEDUCTION "BALANCE 4-25-24 PRUP202303377 Yield North .00 600.00 CHECK 5-01-24 CHECK 33807 I TOTAL> .00 600.00 DATE NUMBER Crescent Communities, LLC 601 South Tryon Street, Suite 800 980-321-6090 Charlotte NC 28202 PLEASE DETACH AND RETAIN FOR YOUR RECORDS hundred dollars and no cents PAY NCDEQ - DIV. OF WATER RESOUR. TO ATTN: NON -DISCHARGE BRANCH THE 1617 MAIL SERVICE CENTER ORDER RALEIGH, NC 27699-1617 OF uc nu,�vrx unsasamwsreocr�i vum+i��i�. veoruaw JPMorgan Chase Bank, N.A. 33807 Dallas, TX DATE 05/01/2024 Timberscan Copy ** VOID * VOID * VOID *" **** NOT NEGOTIABLE **** $ ****600.00 CONSTRUCTION DRAWINGS: GOODWIN (YIELD NORTH INFRASTRUCTURE PHASE I & II HOLLY SPRINGS, NORTH CAROLINA PROJECT NUMBER: 22-MAS-03/PLDMP202200241 PRELIMINARY PLAN APPROVAL DATE: JANUARY 17TH, 2023 UTILITY / MUNICIPALITY CONTACTS: A. TOWN OF HOLLY SPRINGS DEVELOPMENT SERVICES DEPARTMENT 128 SOUTH MAIN STREET HOLLY SPRINGS, NC 27540 (919) 557-3908 CONTACT: SEAN RYAN B. BURIED CABLE LOCATION NC 811 C. DUKE ENERGY (866) 582-6345 TOTAL LENGTHS (LF) WATER 12" DUCTILE IRON: 2,566' 16" DUCTILE IRON: 3,137' RECLAIMED WATER 6" PURPLE PVC: 2,581' 6" DUCTILE IRON: 60, 12" PURPLE PVC: 1,566' GRAVITY SEWER 8" DUCTILE IRON: 950' 8" PVC: 1,371' OFFSITE GRAVITY SEWER (FRIENDSHIP ROAD) 8" DUCTILE IRON 400' 8" PVC 2,988' STREET 5, 360' SIDEWALK 7,204' BUFFER 12,716' SITE DATA TABLE PINS: 0730145033, 0730131203, 0730124768 SITE AREA: 83.47 ACRES ZONING: BRT CU-83.47 ACRES (100%) RIVER BASIN: CAPE FEAR MIN LOT WIDTH/FRONTAGE BRT CU-100' MAXIMUM BUILDING HEIGHT: BRT CU-100' MINIMUM BUILDING HEIGHT: BRT CU-25' PROVIDED BUILDING SETBACK: MINIMUM - 10',MAXIMUM - 30' MINIMUM YARDS: DISTRICT TYPE A: 5'; TYPE B: 10'; TYPE C: 50'; ACCESS BUFFER: 25' MIN. NUMBER OF LOTS IN EACH POD: 1 MAX. NUMBER OF LOTS IN EACH POD: 5 MIN. NUMBER OF LOTS FOR OVERALL SITE: 1 MAX. NUMBER OF LOTS FOR OVERALL SITE: 30 MIN. LOT FRONTAGE 100, EXISTING PARCELS ACREAG EXISTING PIN OWNER E ZONING ALFRED KENT GOODWIN & 0730145033 6.01 AC BRT CU SANDRA GAIL GOODWIN ALFRED KENT GOODWIN & 0730131203 7.14 AC BRT CU SANDRA GAIL GOODWIN 70AC2 0730124768 D.C. GOODWIN FARM BRT CU SURVEY BENCHMARKS: THE TWO BENCHMARKS UTILIZED ARE GPS 20 & GPS 21; CAPPED $" REBAR WITH THE NCGS MONUMENT IDENTIFIED AS "H 218". 1. GPS 20: N: 703700.72 E: 2030739.46 2. GPS 21: N:703831.56 E: 2030736.64 CONSULTANT CONTACTS: OWNER CRESCENT COMMUNITIES, YIELD NORTH LLC CONTACT: CHASE KERLEY 601 S. TRYON ST, SUITE 800 CHARLOTTE, NC 28202 PHONE: 980-321-6284 DEVELOPER/APPLICANT CRESCENT COMMUNITIES CONTACT: CHASE KERLEY 601 S. TRYON ST, SUITE 800 CHARLOTTE, NC 28202 PHONE: 980-321-6284 SITE ENGINEER/ LANDSCAPE ARCHITECT TIMMONS GROUP CONTACT: BLAKE HALL 5410 TRINITY ROAD, SUITE 102 RALEIGH, NC 27607 PHONE: 919-866-4933 VICINITY MAP GENERAL NOTES: 1. CONSTRUCTION DRAWING APPROVAL IS REQUIRED PRIOR TO BEGINNING CONSTRUCTION. DEVELOPMENT FEES (ACREAGE, FEE -IN -LIEU OF ASSESSMENT AND INSPECTION FEES AND OTHERS AS REQUIRED MAY BE APPLICABLE) ARE DUE BEFORE CONSTRUCTION DRAWING APPROVAL. 2. THE ESTIMATED SEWER FLOWS SHOWN ARE BASED ON ASSUMED TENANT MIX AT THE TIME OF THE SUBMITTAL. THE ESTIMATED FLOWS WILL BE UPDATED WITH EACH DEVELOPMENT PLAN SUBMITTAL. 3. THE PLAN IS SUBJECT TO REVISIONS DURING CONSTRUCTION DRAWING APPROVAL PROCESS. 4. THE MONUMENT CONTROL POINTS FOR THIS PROJECT IS: TOWN OF HOLLY SPRINGS GEODETIC MONUMENT "ALFORD 33" PUBLISHED COORDINATES N= 693,650.75'E= 2,041,575.85'ELEV.= 377.10'. THE TOWN OF HOLLY SPRINGS HAS INSTALLED A LOCAL GEODETIC MONUMENTATION GRID, TIED TO NAD83, WITHIN AND SURROUNDING THE TOWN LIMITS. ALL SURVEYED INFORMATION (WHEN ANY PORTION OF THE PROJECT IN DESIGN IS WITHIN 2000 FEET OF THE TOWN'S GEODETIC MONUMENT) SHALL REFERENCE THE NEAREST MONUMENT AND SHALL BE CLEARLY NOTED ON THE FIRST SHEET OF, BOTH CONSTRUCTION PLANS, AND AS-BUILTS SUBMITTED TO THE TOWN. 5. IF THERE IS A GEODETIC MONUMENT LOCATED ON THIS SITE, IT MUST BE PROTECTED OR IF RELOCATION IS NEEDED IT WILL BE THE RESPONSIBILITY OF THE DEVELOPER TO RELOCATE IT WITH SURVEY ACCURACY. 6. ALL CONSTRUCTION SHALL CONFORM TO TOWN OF HOLLY SPRINGS ENGINEERING DESIGN AND CONSTRUCTION STANDARDS. 7. CONSTRUCTION DRAWING APPROVAL IS REQUIRED BEFORE CONSTRUCTION ON THIS PROJECT MAY BEGIN. DEVELOPMENT FEES ARE DUE BEFORE CONSTRUCTION DRAWING APPROVAL. SANITARY SEWER FLOW ESTIMATION PEAK SEWER FLOW: PHASE I (A, C, & G): 23.99 AC @ 3.24 GPM/AC = 77.72 GPM PHASE II (B & D): 29.03 AC @ 3.24 GPM/AC = 94.06 GPM PHASE III (E & F): 23.28 AC @ 3.24 GPM/AC = 75.42 GPM RUNNING TOTAL PEAK SEWER FLOW: 77.74 GPM + 94.06 GPM + 75.42 GPM = 247.20 GPM Sheet List Table Sheet Number Sheet Title C0.0 COVER SHEET C1.0 EXISTING CONDITIONS & DEMOLITION PLAN C2.0 EROSION CONTROL PHASE I C2.1 EROSION CONTROL PHASE II C3.0 OVERALL SITE PLAN C3.1 SITE PLAN C3.2 SITE PLAN C4.0 OVERALL UTILITY PLAN C4.1A WATER MAIN PROFILES C4.2A WATER MAIN PROFILES C4.3A WATER MAIN PROFILES C4.4A WATER MAIN PROFILES C4.5A WATER MAIN PROFILES C4.6A WATER MAIN PROFILES C4.7A WATER MAIN PROFILES C4.213 RECLAIMED WATERLINE PROFILES C4.313 RECLAIMED WATERLINE PROFILES C4.413 RECLAIMED WATERLINE PROFILES C4.513 RECLAIMED WATERLINE PROFILES C4.613 RECLAIMED WATERLINE PROFILES C4.713 RECLAIMED WATERLINE PROFILES C4.4C SANITARY SEWER PLAN AND PROFILE C4.5C SANITARY SEWER PLAN AND PROFILE C4.6C SANITARY SEWER PLAN AND PROFILE C4.7C SANITARY SEWER PLAN AND PROFILE C4.8C SANITARY SEWER PLAN AND PROFILE C4.9C SANITARY SEWER PLAN AND PROFILE C4.10C SANITARY SEWER PLAN AND PROFILE C5.0 OVERALL GRADING PLAN C5.1 GRADING & DRAINAGE PLAN C5.2 STORMWATER DRAINAGE PLAN C5.3 STORMWATER PROFILES - SCM A C5.4 STORMWATER PROFILES - SCM A C5.5 STORMWATER PROFILES - SCM A C5.6 STORMWATER PROFILES - SCM A C5.7 STORMWATER PROFILES - SCM A C5.8 STORMWATER PROFILES - SCM A C5.9 STORMWATER PROFILES - SCM A C5.10 STORMWATER PROFILES - SCM A C5.11 STORMWATER PROFILES - SCM B C5.12 STORM STRUCTURE AND PIPE TABLES C5.13 STORM STRUCTURE AND PIPE TABLES C5.14 DRAINAGE AREA MAP C5.15 SCM DETAILS - POND A C5.16 SCM DETAILS - POND B C5.17 SCM DETAILS C5.18 STORMWATER COMPLIANCE PLAN C6.0 OVERALL ROADWAY LAYOUT C6.1 ROADWAY PLAN & PROFILES C6.2 ROADWAY PLAN & PROFILES C6.3 ROADWAY PLAN & PROFILES C6.4 ROADWAY PLAN & PROFILES C6.5 ROADWAY PLAN & PROFILES C6.6 CROSS SECTIONS STA. 113+77.80 TO 108+27.80 C6.7 CROSS SECTIONS STA. 107+77.80 TO 102+27.80 C6.8 CROSS SECTIONS STA. 101+77.80 TO 100+27.80 C6.9 CROSS SECTIONS STA. 100+00 TO 103+50 C6.10 CROSS SECTIONS STA. 100+00 TO 105+50 C6.11 CROSS SECTIONS STA. 106+00 TO 106+50 C7.0 NOTES & DETAILS C7.1 NOTES & DETAILS C7.2 NOTES & DETAILS C7.3 NOTES & DETAILS C7.4 NOTES & DETAILS 1-1.0 TREE PRESERVATION PLAN L2.0 OVERALL LANDSCAPE PLAN L2.1 LANDSCAPE NOTES & DETAILS E1.0 LIGHTING PLAN R1.00 COVER SHEET R2.00 GENERAL NOTES, DETAILS & CONVENTIONAL SYMBOLS R2.01 TYPICAL SECTIONS R3.00 EXISTING CONDITIONS & PLAN & STRIPING/SIGNAGE SHEET R3.01 GRADING & PROFILE SHEET R4.00 EXISTING CONDITIONS & PLAN & STRIPING/SIGNAGE SHEET R4.01 GRADING & PROFILE SHEET R5.00 EXISTING CONDITIONS & PLAN & STRIPING/SIGNAGE SHEET R5.01 GRADING & PROFILE SHEET R7.01 ENTRANCE PROFILES R9.01- R9.02 TRAFFIC CONTROL PLANS R10.01- R10.13 CROSS SECTIONS CERTIFICATION BLOCK: I CERTIFY THAT THESE PLANS WERE PREPARED AND THAT THIS PROJECT SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING PLANS, THE LATEST EDITION OF THE ENGINEERING DESIGN & CONSTRUCTION STANDARDS OF THE TOWN OF HOLLY SPRINGS & OTHER APPLICABLE TOWN ORDINANCES & POLICIES. THE ENGINEER WHOSE SEAL & SIGNATURE APPEAR BELOW CERTIFIES THE TOWN OF HOLLY SPRINGS ENGINEERING DESIGN AND CONSTRUCTION STANDARDS HAVE BEEN THOROUGHLY REVIEWED FOR APPLICABILITY TO THIS PARTICULAR PROJECT. Qo��p60�pppp�6 C APoj�000 o • • o o J�'y�� o SEAL 34 '74 o32o23 oo� •• I iV ,s C66 E 0 U N O O 0 n E N E w U Q 3 U) U) U) U) U) U, U N zzzz z � wwww w _-, a i ,y,�oM O a= 0 0 0 0 0 Ufa, a U U U U U z w � M zzzz z X U g < a Q w 0000 0fC30 0 z T Ln r .L V/ V/ V/ V/ V/ V/ o0� w 0 000 0 0 0 0 O H U)U)U)U) U) �� »»> o' 0 c� 0 F- 0 W w U a z 0 0 ►7 ry) ry) ry) ry) ry) N N N N N w o 0 0 0 0 N N N N N Q O i N (y) (n �o00rno .� DATE 0511912023 D RAW N BY T. MORRISO/V DESIGNED BY B. MCLAMB CHECKED BY B HALL SCALE AS SHOWN IHq 0 z U J O i u W 2 w O () w 000 z > zwC) C J w H� 30B NO. 54318 SHEET NO C0.0 c 0 0 c N T C O O E U CN O C � U 0 Doe o C� c z a 0 :5 6 F- a 0 9 T C o Q U O L U- N o •O U � o U }' xa � o C E U ,� O U1 _0D U o U N o > U) o O N L 1 , / I , / I , / I 1 /-� EX STREAM /-/- \ . ?' «� r'a.±,`•'j``� 'rii l iiii,� ,I, i;ll l 1 // \ , \.:�.:` \ s, i`.d_ �� `�->_o``I�:-%a/, I I�rririiiii, r ```\•`O• `M`,♦ ��''.G \ 4GJ �` _ �MNp� ♦ ` ^l `\o `\�, \ \` .` ` \ , ,/ 'l;!„�3•/I B7�%i i, ` \ \ \ Rim - 328.51' I ♦ 11 M``,�"�%"-�`�_M`�; ,-`� ^' ` 1`\`\ if /�% 1//,,,j ,i ii%%'%r, `\\\\, , (,:y�i '`, `\<``'' 111``i//I �rd �:•J♦:/\` ` 41/ `1 •' `\`:,' :,� i ll�ii'/i, i�,,, : / `` `\ �` `\ = O,t(SE)-31276' M1lannnl2800- jl' `\ " ` `\ � �i,%!/1%i;, 'i.. �\1\II' 1 \ - � 1 i •/� '"`red.`" 1 '\� '/%{ %.l B/�//'%iil�i/'i�� 'I ; \I ; � I Rim = 328.00' `\ \ �♦�Z�/'_iib//tl`ll 11` X - `�, 1\ ✓ �2^ ` % / lljl;l//,,,/%i / 111♦ O,t(S-312.60' \ ..K\;. �hAE�./�.1./11. A' \. .11\. �/L-�i'``"`!i �i'. il�ll✓.////„///� 1./1 Out (SW)-312.50' REMOVE EX DRIVE AND BUILDING /' --�-�� .. '•• 5 /_'-�.�/1. 11'1, )1\I )Y/.4/1,/ ''B / 'I 1' ••• �+� ��. i5<7�i>�%�lu.%•i�iiill�iili`�I/'iililli lli� •\ . N , 60' PRIVATE EASEMENT (t- r'r-4^ir 1 EX WETLAND ADJACENT PARCELS NUMBER PIN OWNER ACREAGE ZONING DEED BOOK () 0720904923 LANDCO LLC, CMP 205.15 BRT DB-019010 PG-02625 MANAGEMENT LLC 2O 0730034435 TARRENCE, JAR ES EDWARD 3.96 RR DB-016707 PG-01850 ANDREAS, MICHAEL T 3O 0730038536 ANDREAS, LYNN B 4.00 RR DB-014179 PG-00361 ® 0730043464 HASTINGS, JEFFREY GOODWIN 12.54 RR DB-014587 PG-01572 TRUSTEE FBO BOBBY STEELE 5O 0730143907 OLIVE, BENTLEY J OLIVE, 16.33 RR DB-016236 PG-02557 LEANNE C © 0730251576 FORNESS, WILLIAM FORNESS, 0.24 RR DB-017237 PG-02042 NOELLE EX WETLAND % 30' CAPE FEAR STREAM BUFFER 1! , T 30' CAPE FEAR STREAM BUFFER EX WETLAND =� EX STREAM SCALE 1 "=300' 0 360' 600' co co 0 Q z / / \ 1 1\ -------------------- A O 8 O7 0730252479 MOORE, GREGORY O MOORE, 0.80 RR DB-014979 PG-00128 JENNIFER C ® 0730534863 LENNAR CAROLINAS LLC 229.19 RR DB-017612 PG-01928 90 0730330409 WAKE COUNTY 70.94 RR DB-018637 PG-02625 POE, WILLIAM DOUGLAS POE, 10 0730217472 111.41 RR DB-009235 PG-00530 DARYL POE 11 0730118503 MILLS, STEPHEN V MILLS, 10.20 RR DB-003052 PG-00758 NANCY O 12 0730110581 BELL, RONALD T 11.29 RR DB-003809 PG-00474 1\\ DEMOLITION LEGEND REMOVE XREMOVE - - LIMITS OF WORK PHASE I BOUNDARY LINE DEMOLITION NOTES: 1. NOTIFY OWNER AND ARCHITECT IMMEDIATELY OF UTILITY SERVICE INTERRUPTIONS TO NEIGHBORING PROPERTIES. 2. UTILITIES ENCOUNTERED THAT ARE NOT INCLUDED WITHIN THE EXISTING CONDITIONS PLANS SHALL BE REMOVED OR RELOCATED PER THE OWNER, ARCHITECT AND UTILITY PROVIDERS DIRECTION. 3. EVERYTHING WITHIN THE LIMITS OF DISTURBANCE SCHEDULED TO BE DEMOLISHED SHALL ONLY PROCEED AFTER ALL TREE PROTECTION FENCE AND PERIMETER EROSION AND SEDIMENT CONTROL MEASURES HAVE BEEN INSTALLED AND INSPECTED PER THE EROSION CONTROL PLAN. INSTALL ADDITIONAL EROSION AND SEDIMENT CONTROL MEASURES AS NECESSARY TO PREVENT SEDIMENT LADEN RUNOFF FROM EXITING THE SITE. 4. ALL TRASH AND MISCELLANEOUS DEBRIS SHALL BE REMOVED FROM THE SITE AND DISPOSED OF IN A LEGAL MANOR. 5. ALL WORK SHALL BE IN ACCORDANCE WITH THE STATE AND COUNTY STANDARDS. 6. OPEN BURNING OF TREES, LIMBS, STUMPS, AND CONSTRUCTION DEBRIS ASSOCIATED WITH THIS DEVELOPMENT IS PROHIBITED. 7. ALL EXISTING FIRE HYDRANTS TO REMAIN CLEAR AND OPERATIONAL DURING ALL PHASES OF CONSTRUCTION SURVEY NOTES: 1. BOUNDARY SURVEY PREPARED FOR GOODWIN FARM LLC. 2. PORTIONS OF THIS PROPERTY LIE IN ZONE AE, A SPECIAL FLOOD HAZARD AREA. PER FIRM #3720073000K. PANEL 0730, EFFECTIVE DATE JULY 19, 2022. 3. HORIZONTAL CONTROL IS BASED ON NC STATE GRID, NAD'83 (2011) AS DETERMINED BY GPS. ALL DISTANCES SHOWN ARE GROUND DISTANCES. 4. THIS SURVEY WAS PREPARED WITHOUT THE BENEFIT OF A TITLE SEARCH. OTHER EASEMENTS MAY EXIST ON THIS SITE. 5. EASEMENTS AND RIGHTS -OF -WAYS SHOWN ARE PER DEEDS AND PLATS OF RECORD. 6. NOT ALL IMPROVEMENTS HAVE BEEN SHOWN. GENERAL NOTES: 1. THE SITE IS LOCATED WITHIN THE CAPE FEAR RIVER BASIN AND IS SUBJECT TO THE BUFFER PROVISIONS OF SECTION 7.06 0.4(E)(3) OF THE HOLLY SPRINGS UNIFIED DEVELOPMENT ORDINANCE. 2. NO FEMA IDENTIFIED FLOODWAYS AND/OR 100-YEAR FLOOD PLAINS ARE PRESENT ON SITE. 3. THE SITE IS NOT WITHIN A WATERSHED PROTECTION AREA. 4. ADJACENT PROPERTY INFORMATION FROM WAKE COUNTY GIS. 5. ZONING DESIGNATIONS FROM HOLLY SPRINGS ZONING MAP AND FROM WAKE COUNTY GIS. 6. CONTRACTOR RESPONSIBLE FOR ALL DEMOLITION REQUIRED WITHIN THE LIMITS OF WORK SHOWN. LEGEND IPF - IRON PIPE FOUND OD MH DRAINAGE ® SPRINKLER BOX O IRF - IRON ROD FOUND D8t1 SPRINKLER HEAD • CP -COMPUTED BOUNDARY POINT OO MH SANITARY 61 CP - COMPUTED EASEMENT POINT OE MH ELECTRIC ® SPRINKLER VALVE 0 CMF - CONCRETE MONUMENT 0 GAS TEST LOCATION Q MNF - MA NAIL FOUND O MH TELEPHONE GAS METER RSF - RAILROAD SPIKE FOUND © MH WATER v GAS VALVE O CSF -COTTON SPINDLE FOUND ELECTRIC BOX FLAG POLE BFP BACKFLOW PREVENTER ❑T TELEPHONE PEDESTAL VW WATER VAULT © CABLE TV PEDESTAL TREE VT TELEPHONE VAULT BOLLARD TC TRAFFIC CONTROL BOX SIGN VP POWER VAULT O ELECTRIC METER BOREHOLE VU UTILITY VAULT WATER METER ® AC UNIT O WF - WETLAND FLAG ® MAILBOX RCP - REINFORCED CONCRETE PIPE WATER VALVE CMP - CORRUGATED METAL PIPE ® CLEAN OUT VCP - VITRIFIED CLAY PIPE FIRE HYDRANT DIP -DUCTILE IRON PIPE POWER POLE < GUY HDPE - HIGH DENSITYPOLYETHYLENE PIPE 0 WELL FES - FLARED END SECTION LIGHT POLE MKF - FIBER OPTIC MARKER (a MONITORING WELL MKG - GAS MARKER YARD LIGHT TVP - TELEVISION PEDESTAL GROUND LAMP O SIGP - SIGNAL POLE ROOF DRAIN HVAC - HEATING, VENTILATION AND AIR CONDITIONING (D-+ WATER SPIGOT LSA -LANDSCAPED AREA -------------------------- DEED LINE R / W - RIGHT-OF-WAY - - - LINE NOT SURVEYED P/L- PROPERTY LINE C/L-CENTERLINE - -STORMLINE NTS - NOT TO SCALE SANITARYLINE GV- GAS VALVE CB - CATCH BASIN ------ ----------------FENCE GI -GRATE INLETOVERHEAD Yl - YARD INLET POWER LINE Cl - CURB INLET -__ _____ _____ _____ _____ _____ _____ __-PAINTED GAS LINE EP - EDGE OF PAVING TBC - TOP BACK OF CURB POWER LINE CCR - CHATHAM COUNTY RECORD rM_____. _____„ _____„ ____PAINTED STORM LINE WCR -WAKE COUNTY --PAINTED TELEPHONE LINE RECORDS DB - DEED BOOK---w-----w-----w-----w-----w-----w---PAINTED WATERLINE PB - PLAT BOOK PG - PAGE EDGE OF TREELINE SF - SQUARE FEET O t ssT s �o SEAL ; 34 '74 Q ; If o3 2oZ3 o� � ••�I iV ,s' i� -,�r �o�o E O U N O O o N W U = z 4-: Q 3 LuUUI U- N L�ue C O M co (Dw� Z J m X IB LL 0 O C)r Lr) L C,� o� Lo0'� J W U)U)U)U) U) z z z z z W W W W W O 0 0 0 0 0 a U U U U U U W 0 0 0 0 0 C) W W W W W O_ aaaa a U) U) U) U) U) U) z z z z z W 0 0 0 0 0 � »» > rr) rr) rr) rr) rr) N N N N N W 0 0 0 0 O N N N N N Q O I N m m 0 (r) ,--I N r-I O �o 00 m o O O O .-I ,-I DATE 0511912023 D RAW N BY T. MORRISO/V DESIGNED BY B. MCLAMB CHECKED BY B HALL SCALE AS SHOWN I..L Q J O Li J uz o LLJ 0 z 06 U°z u O ^� o = o O C) (V OZ U U) zL x >Q LLJ 0 J uj uz 0 O O V 30B NO. 54318 SHEET NO. C1.0 � o cn �u� � z 0 0 c O _c O In � c 0 0 C N T c O � Et 0 i c N O c O U 0 L oo� o (D \ a c c z a 0 �c � c a 0 9 T c o a) }' 0- U O 2 O- N N c o •O U � o U }' x a E c U 0 U o � (D U) o O N -O 0 c _c 0 � U� c N O O a � 0 a) o U) N >, _cc � 0 L_ SITE DATA TABLE PINS: 0730145033,0730131203, 0730124768 SITE AREA: 83.47 ACRES ZONING: BRT CU-83.47 ACRES (100%) RIVER BASIN: CAPE FEAR MIN LOT WIDTH/FRONTAGE BRT CU-100' MAXIMUM BUILDING HEIGHT: BRT CU-100' MINIMUM BUILDING HEIGHT: BRT CU-25' PROVIDED BUILDING SETBACK: MINIMUM - 10', MAXIMUM - 30' MINIMUM YARDS: DISTRICT TYPE A: 5'; TYPE B: 10'; TYPE C: 50'; ACCESS BUFFER: 25' MIN. NUMBER OF LOTS IN EACH POD: 1 MAX. NUMBER OF LOTS IN EACH POD: 5 MIN. NUMBER OF LOTS FOR OVERALL SITE: 1 MAX. NUMBER OF LOTS FOR OVERALL SITE: 30 MIN. LOT FRONTAGE 100, SHEET REFERENCES TYPICAL SECTIONS R2.01 ROADWAY PLAN & STRIPING R3.00, R4.00, & SHEET R5.00 GRADING & PROFILE SHEET R3.01 R4.01 & R5.01 ENTRANCE PROFILES R7.01 CROSS SECTIONS R10.01 - R10.13 PARCEL INFORMATION ANDREAS, MICHAEL T ANDREAS L YNN B 0730038536 DB 014179 PG 00361 AREA = 4.00 AC / / / / / PARCEL INFORMATION LANDO LLC, CMP MANAGEMENT LLC PIN: 0720904923 DB 019010 PG 02625 AREA = 205.15 AC MIN. 30' SETBACK MIN. 30' SETBACK / 'c" MIN. 30' SETBACK 2 LANE NON RESIDENTIAL COLLECTOR / MIN. 5' SETBACK / / / / / / / / / / - R - MIN. 30' TB K 30' CAPE FEAR STREAM BUFFER EX STREAM EX. WETLAND (TYP) MI . 30' SE If 1. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE TOWN OF HOLLY SPRINGS AND OSHA STANDARDS. 2. THE CONTRACTOR SHALL RECYCLE ALL PAVING MATERIALS REMOVED FROM THE SITE AND SHALL PROVIDE DOCUMENTATION THAT THE MATERIALS HAVE BEEN RECYCLED. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OFF -SITE DISPOSAL OF ALL WASTE MATERIALS GENERATED DURING CONSTRUCTION AND FOR OBTAINING ALL APPLICABLE PERMITS FOR OFF -SITE STOCKPILES AND/OR WASTE AREAS. 4. CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGES DURING CONSTRUCTION AND SHALL MAKE REPAIRS AT NO EXPENSE TO THE OWNER. 5. CURB RADII ARE DIMENSIONED FROM FACE OF CURB OR EDGE OF PAVEMENT. 6. RAISE ALL STRUCTURES WITHIN THE AREAS TO BE OVERLAID OR PAVED WITH ASPHALT SUCH THAT THE TOP OF THE STRUCTURE EQUALS THE FINISH GRADE OF THE NEW ASPHALT. 7. THIS PROJECT IS LOCATED IN THE TRIASSIC BASIN SO ROADWAYS MUST BE CONSTRUCTED IN ACCORDANCE WITH SECTION 3.02 J OF THE ENGINEERING DESIGN AND CONSTRUCTION STANDARDS. FOR WORK WITHIN THE NCDOT RIGHT OF WAY: 8. ALL PAVING SHALL BE PERFORMED BY A NCDOT APPROVED CONTRACTOR. 9. ALL PAVEMENT MARKINGS SHALL BE PERFORMED BY A NCDOT APPROVED CONTRACTOR. 10. THIS PROJECT IS SUBJECT TO SUPERPAVE MIX REQUIREMENTS AND FILL IMPLEMENTATION OF THE QMS (QUALITY MANAGEMENT SYSTEM) SPECIFICATIONS FOR ALL ASPHALT PAVEMENTS. 11. THE CONTRACTOR MUST NOTIFY NCDOT 48 HOURS IN ADVANCE PRIOR TO BEGINNING WORK. 12. BOARDWALKS ARE REQUIRED TO OBTAIN A BUILDING PERMIT. GENERAL SIGNAGE AND STRIPING NOTES 1. ALL SIGNING AND PAVEMENT MARKING SHALL BE IN ACCORDANCE WITH THE MOST CURRENT EDITION OF EACH OF THE FOLLOWING AND AMENDMENTS AND SUPPLEMENTS THERETO: A. MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES. B. NORTH CAROLINA DEPARTMENT OF TRANSPORTATION ROADWAY STANDARDS. C. THE 2003 INTERNATIONAL FIRE CODE. 2. SIGN LOCATIONS ARE APPROXIMATE AND SHALL BE MODIFIED IN THE FIELD TO AVOID CONFLICT WITH UNDERGROUND UTILITIES OR OTHER OBSTRUCTIONS AND TO COMPLY WITH STANDARDS REFERENCED IN NOTE 1 ABOVE. 3. PROVIDE ALL SIGNS, SIGN POSTS AND PAVEMENT MARKINGS. 4. ALL PAVEMENT MARKINGS WITHIN THE NCDOT PUBLIC RIGHT OF WAY SHALL BE 0.125 MIL THERMOPLASTIC. 5. REFER TO STREET SIGN TOWN STANDARD DETAIL, HS 361 FOR POLE STYLE AND COLOR REFER TO GOODWIN PUMP STATION FOR SITE PLAN DEVELOPMENT AND INFORMATION PARCEL INFORMATION WAKE COUNTY PIN: 0730330409 DB 018637 PG 02625 AREA = 70.94 AC PARCEL INFORMATION POE, WILLIAM DOUGLAS POE, DARYL POE PIN: 0730217472 DB 009235 PG 00530 AREA = 111.41 AC HATCHING LEGEND HEAVY DUTY ASPHALT LIGHT DUTY ASPHALT HEAVY DUTY CONCRETE CONCRETE SIDEWALK STONE -MECHANICAL YARD STAMPED CONCRETE ® DECORATIVE CONCRETE PAVING GRASS MEDIAN LEGEND PHASE I BOUNDARY LINE PHASE II BOUNDARY LINE 1. M M 0 z MIN. 30' SETBACK SCALE 1 "=150' 0 150' 300' Qoo��aoo��ooaa° C ARO °000 q i SEAL 3474 Q ; I l 0 3 2 G0lc2Y3Yn'�!; C6* E 0 U "D 0 � o N E U LLI E z } cm 0 U N tLL_� 9 c� LU°NoM ax -'co C� !� J X � , U_ 0 0 f)(Ln m _ �'�J- L �00 o rn Ln rn J LU 0 c� 0 0 W > w U Q Z O 0 U)U)U)U) U) z z z z z wwww w z 2: 2: 2: 2: 2: O 0000 0 a U U U U U z z z z z w 0000 0 W W W W W O a a a a a U) U) U) U) U) U) z z z z z w 0 0 0 0 0 0 0 0 0 0 c� U) U) U) U) U) w w w w w rr) rr) rr) rr) rr) N N N N N w o 0 0 0 0 N N N N N Q O .-i N rr) rr) p rr) .-iN.-i O l0 00 0)i C) DATE 0511912023 D RAW N BY T. MORRISOIV DESIGNED BY B. MCLAMB CHECKED BY B HALL SCALE AS SHOWN 30B NO. 54318 SHEET NO. C3.0 � o X �cn cn �ci O U Qcl '2 o� �o E - i O 0 o 0--- 0 U� ci z 0 0 �o o N 0 � o U � o X � N -0 N N .- E L_ O O V, N � E U .> o cn _0 =) U a U a� O 0 N O b a X L GENERAL SIGNAGE AND STRIPING NOTES 1. ALL SIGNING AND PAVEMENT MARKING SHALL BE IN ACCORDANCE WITH THE MOST CURRENT EDITION OF EACH OF THE FOLLOWING AND AMENDMENTS AND SUPPLEMENTS THERETO: A. MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES. —UCATV't/� B. NORTH CAROLINA DEPARTMENT OF TRANSPORTATION ROADWAY — --UCATV — — — 20' MEDIAN W/ 1.S-C&G STANDARDS. - C. THE 2003 INTERNATIONAL FIRE CODE. _ - - - 2. SIGN LOCATIONS ARE APPROXIMATE AND SHALL BE MODIFIED IN THE FIELD TO AVOID CONFLICT WITH UNDERGROUND UTILITIES OR OTHER OBSTRUCTIONS AND TO COMPLY WITH STANDARDS REFERENCED IN NOTE 1 ABOVE. R-7zW r WR/ - R fW- TV UCATV U�ATV — UCATV —UCATV UCATV — UCAT LL - '_ _ _ �2 - - - _ _ •6 12' - - wig 115' ROW WOODS CREEK RD 3. PROVIDE ALL SIGNS, SIGN POSTS AND PAVEMENT MARKINGS. _ -` ----- - --_ 4. ALL PAVEMENT MARKINGS WITHIN THE NCDOT PUBLIC RIGHT OF WAY SHALL BE 0.125 MIL THERMOPLASTIC. 77 5. REFER TO STREET SIGN TOWN STANDARD DETAIL, HS 361 FOR POLE STYLE AND COLOR _ 100' TAPER LENGTH FOR DESIGN SPEED OF 50 MPH 150' MINIMUM POD A DECELERATION 9.36 AC LENGTH 60' FIRE \ TRUCK - \ TURNAROUND Aygs�2 \ 15' LANE WI \ SIGHT TRIANGLE POD B \ 15'X305' 7.76 AC \ \59' PUBLIC R/W o �'LjNc C3? POD E 16± ACRES UCATV UCATV UCATV — ---------------- ► 12' / ------------------- - - _ 3------------------ 7 12' ► ---- _ - - ------ R40' R40' R40' � III IIIIIII R40 100' STORAGE LENGTH L5' UTILITY STRIP A � 10' SIDEPATH EAST BOUND RIGHT TURN LANE WITH 200' OF STORAGE AND �'� T EX WETLAND (TYP.) APPROPRIATE TAPER LENGTH 5' SIDEWALK (TYP.) PER NCDOT R30' { . SIGHT TRIANGLE r . 15'X305' i �� �� EX STREAM 29 r � �i :. .:. ,• I R1800 T I 150' MINIMUM : {, DECELERATION F : � : I 100, LENGTH R30' a1 TAPER _ LENGTH i i 30' CAPE FEAR STREAM : BUFFER SIGHT TRIANGLE I 15'X305' — j �1 ' R40' ,�..... i : $5' B . R30' R30" R47100' i - --- L R40' �O �:• 5' SIDEWALK (TYP.) f.. � 123' 5' UTI I � 5 UTILITY S R / L T�'gSTRIP � 5 UTILITY STRIP N �& SIDEWALK \ / / 35' BOC-BOC 15' SCM MAINTENANCE & 5' SIDEWALK (TYP.) � � � ::; � � ACCESS EASEMENT W POD C 12.61 / REFER TO GOODWIN PUMP STATION FOR SITE PLAN DEVELOPMENT AND INFORMATION HATCHING LEGEND HEAVY DUTY ASPHALT LIGHT DUTY ASPHALT HEAVY DUTY CONCRETE CONCRETE SIDEWALK STONE -MECHANICAL YARD STAMPED CONCRETE ® DECORATIVE CONCRETE PAVING EX STREAM GRASS MEDIAN z SCM MAINTENANCE & SCM B ' s ACCESS EASEMENT MIN. 30' SETBACK f RETAINING WALL -� LENGTH = ±193 LF \� \ 50 TYPE C PERIMETER BUFFER LEGEND PHASE I BOUNDARY LINE PHASE II BOUNDARY LINE MAXIMUM HEIGHT = ±8.50' GENERAL NU I Eb x r / 1. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE TOWN OF HOLLY i \ SPRINGS AND OSHA STANDARDS. '3 f :� 30,: SCM A r,♦♦� _ / 80' THROAT / ♦ DISTANCE FOR TURN AROUND (SEE C7.0 FOR DETAIL) EX WETLAND (TYP) I : . I I i f SIGHT TRIANGLE 15'X305' r f. . / f .y ',, o . ♦♦�♦' 7, SIGHT TRIANGLE 15'X305' / 30 CAPE FEAR STREAM BUFFER POD D 7.28 AC 5' SIDEWALK (TYP.) 30' CAPE FEAR STREAM BUFFER 2. THE CONTRACTOR SHALL RECYCLE ALL PAVING MATERIALS REMOVED FROM THE SITE AND SHALL PROVIDE DOCUMENTATION THAT THE MATERIALS HAVE BEEN RECYCLED. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OFF -SITE DISPOSAL OF ALL WASTE MATERIALS GENERATED DURING CONSTRUCTION AND FOR OBTAINING ALL APPLICABLE PERMITS FOR OFF -SITE STOCKPILES AND/OR WASTE AREAS. 4. CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGES DURING CONSTRUCTION AND SHALL MAKE REPAIRS AT NO EXPENSE TO THE OWNER. 10' MIN. MAINTENANCE 5. CURB RADII ARE DIMENSIONED FROM FACE OF CURB OR EDGE OF PAVEMENT. & ACCESS EASEMENT 6. RAISE ALL STRUCTURES WITHIN THE AREAS TO BE OVERLAID OR PAVED WITH ASPHALT SUCH THAT THE TOP OF THE STRUCTURE EQUALS THE FINISH GRADE OF THE NEW ASPHALT. 7. THIS PROJECT IS LOCATED IN THE TRIASSIC BASIN SO ROADWAYS MUST BE CONSTRUCTED IN ACCORDANCE WITH SECTION 3.02 J OF THE ENGINEERING DESIGN AND CONSTRUCTION STANDARDS. FOR WORK WITHIN THE NCDOT RIGHT OF WAY: 8. ALL PAVING SHALL BE PERFORMED BY A NCDOT APPROVED CONTRACTOR. 9. ALL PAVEMENT MARKINGS SHALL BE PERFORMED BY A NCDOT APPROVED CONTRACTOR. 10. THIS PROJECT IS SUBJECT TO SUPERPAVE MIX REQUIREMENTS AND FILL IMPLEMENTATION OF THE QMS (QUALITY MANAGEMENT SYSTEM) SPECIFICATIONS FOR ALL ASPHALT PAVEMENTS. 11. THE CONTRACTOR MUST NOTIFY NCDOT 48 HOURS IN ADVANCE PRIOR TO BEGINNING WORK. SCALE 1 "=60' 120' C AROT °000 49SSs jQ'� o SEAL a 34�74 a Q ; Il 03 2023 0 U � o N U w E z } ~ _ 3 a 3 0 U N d LL N c� w 0 o M a2 -'co J L X < fuJ_ 0 0 Ln rn L �� CD,� Ln0) J w V) rr 0 c� 0 0 w w_ 2 U Q z O 0 U) U) U) U) U) z z z z z w w w w w O 0 0 0 0 0 a U U U U U z z z z z uu w 0000 0 C) W W W W W O a a a a a U) U) U) U) U) U) z z z z z w 0000 0 U)U)U)U) U) rr) rr) rr) rr) rr) N N N N N w o 0 0 0 0 N N N N N Q C) N (r) (r) p (n + -i N + -i o �D00rno .� DATE 0511912023 D RAW N BY T. MORRISO/V DESIGNED BY B. MCLAMB CHECKED BY B HALL SCALE AS SHOWN I —I u_ z I --I 0 z uo< U �\ w = O z C) 00 0 zw C J W z H� r•� 30B NO. 54318 SHEET NO. C3.1 o� -Do U0 0 V) CD �u� �z 0 o � o� � o 0 0 E i 0 0 o u 0 � o co � 0 0 z 0 o We 0 Q� o E N 0 0 o 0 X� E 0 V o E U > o cn u U o � o f ---- �- 1- — — 15' � POD F 13.64 AC 35' B-B 5' UTILITY S RIP 2.5' i..i ' 1 � '1 1111111111 � �-� -� R30'. . . . . WAM 1217'. R30' .. P5. —i MIN. 5' SETBACK POD F 13.64 AC SCALE 1 "=60' 0 60' 120' MIN. 30' SETBACK REFER TO GOODWIN PUMP STATION FOR SITE PLAN DEVELOPMENT AND INFORMATION HATCHING LEGEND HEAVY DUTY ASPHALT LIGHT DUTY ASPHALT HEAVY DUTY CONCRETE CONCRETE SIDEWALK STONE -MECHANICAL YARD STAMPED CONCRETE ® DECORATIVE CONCRETE PAVING GRASS MEDIAN I r=rr=nin PHASE I BOUNDARY LINE PHASE II BOUNDARY LINE 1. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE TOWN OF HOLLY SPRINGS AND OSHA STANDARDS. 2. THE CONTRACTOR SHALL RECYCLE ALL PAVING MATERIALS REMOVED FROM THE SITE AND SHALL PROVIDE DOCUMENTATION THAT THE MATERIALS HAVE BEEN RECYCLED. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OFF -SITE DISPOSAL OF ALL WASTE MATERIALS GENERATED DURING CONSTRUCTION AND FOR OBTAINING ALL APPLICABLE PERMITS FOR OFF -SITE STOCKPILES AND/OR WASTE AREAS. 4. CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGES DURING CONSTRUCTION AND SHALL MAKE REPAIRS AT NO EXPENSE TO THE OWNER. 5. CURB RADII ARE DIMENSIONED FROM FACE OF CURB OR EDGE OF PAVEMENT. 6. RAISE ALL STRUCTURES WITHIN THE AREAS TO BE OVERLAID OR PAVED WITH ASPHALT SUCH THAT THE TOP OF THE STRUCTURE EQUALS THE FINISH GRADE OF THE NEW ASPHALT. 7. THIS PROJECT IS LOCATED IN THE TRIASSIC BASIN SO ROADWAYS MUST BE CONSTRUCTED IN ACCORDANCE WITH SECTION 3.02 J OF THE ENGINEERING DESIGN AND CONSTRUCTION STANDARDS. FOR WORK WITHIN THE NCDOT RIGHT OF WAY: 8. ALL PAVING SHALL BE PERFORMED BY A NCDOT APPROVED CONTRACTOR. 9. ALL PAVEMENT MARKINGS SHALL BE PERFORMED BY A NCDOT APPROVED CONTRACTOR. 10. THIS PROJECT IS SUBJECT TO SUPERPAVE MIX REQUIREMENTS AND FILL IMPLEMENTATION OF THE QMS (QUALITY MANAGEMENT SYSTEM) SPECIFICATIONS FOR ALL ASPHALT PAVEMENTS. 11. THE CONTRACTOR MUST NOTIFY NCDOT 48 HOURS IN ADVANCE PRIOR TO BEGINNING WORK. GENERAL SIGNAGE AND STRIPING NOTES 1. ALL SIGNING AND PAVEMENT MARKING SHALL BE IN ACCORDANCE WITH THE MOST CURRENT EDITION OF EACH OF THE FOLLOWING AND AMENDMENTS AND SUPPLEMENTS THERETO: A. MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES. B. NORTH CAROLINA DEPARTMENT OF TRANSPORTATION ROADWAY STANDARDS. C. THE 2003 INTERNATIONAL FIRE CODE. 2. SIGN LOCATIONS ARE APPROXIMATE AND SHALL BE MODIFIED IN THE FIELD TO AVOID CONFLICT WITH UNDERGROUND UTILITIES OR OTHER OBSTRUCTIONS AND TO COMPLY WITH STANDARDS REFERENCED IN NOTE 1 ABOVE. 3. PROVIDE ALL SIGNS, SIGN POSTS AND PAVEMENT MARKINGS. 4. ALL PAVEMENT MARKINGS WITHIN THE NCDOT PUBLIC RIGHT OF WAY SHALL BE 0.125 MIL THERMOPLASTIC. 5. REFER TO STREET SIGN TOWN STANDARD DETAIL, HS 361 FOR POLE STYLE AND COLOR Qo���60Q���0p6° C ARO49 T °000 �wa���� Lf p SEAL 7 a 34�74 a 2023 � �p 0 Q ➢s� tl Q 0 U (n O O O N E w u E 0 U N d W � N �OoM a.= -'co (3 0 p Z Lu 01% J x M LL 0 O Ln m _ E L c)� o � Ln rn J w F- 4 U) U) U) U) U) z z z z z w w w w w O 0 0 0 0 0 a U U U U U z z z z z U w 0000 0 0 z w w w w w O a a a a a U) U) U) U) U) U) z z z z z w 0 0 0 0 0 U) U) U) U) U) w w w w w ry) ry) ry) ry) ry) N N N N N W O O O O O N N N N N Q (D i N (y) (y) 0 rn i N i O to 00 0) O i DATE 0511912023 D RAW N BY T. MORRISO/V DESIGNED BY B. MCLAMB CHECKED BY B HALL SCALE AS SHOWN z J n 30B NO. 54318 SHEET NO C3.2 o � -DO a) z V) z un z z 0 o � o� a 0 u -0L 0 0 0 u 0 L z o co � 0 0 z 0 0 0 0 Q o o E N 0 0 0 E 0 V o E U > o cn u 0 o � 0 a L SITE DATA TABLE - 0730145033,0730131203, PINS: 0730124768 SITE AREA: 83.47 ACRES ZONING: BRT CU-83.47 ACRES (100%) RIVER BASIN: CAPE FEAR MIN LOT WIDTH/FRONTAGE BRT CU-100' MAXIMUM BUILDING HEIGHT: BRT CU-100' MINIMUM BUILDING HEIGHT: BRT CU-25' PROVIDED BUILDING SETBACK: MINIMUM - 10', MAXIMUM - 30' MINIMUM YARDS: TYPE A: 5'; TYPE B: 10'; TYPE C: 50'; DISTRICT ACCESS BUFFER: 25' MIN. NUMBER OF LOTS IN EACH POD: 1 MAX. NUMBER OF LOTS IN EACH POD: 5 MIN. NUMBER OF LOTS FOR OVERALL SITE: 1 / MAX. NUMBER OF LOTS FOR OVERALL SITE: 30 MIN. LOT FRONTAGE 100, O / Gv / / P / zR / m I / / O EXISTING 12" ENTERPRISE GAS LINE II w s I d II O - - - - - - - - - - - - `I EX. WETLAND EX. STREAM M M 0 Q z u5 CREEK RD EX. STREAM 30' CAPE FEAR STREAM BUFFER SCALE 1 "=300' 0 300' 600' REFER TO GOODWIN PUMP STATION FOR SITE PLAN DEVELOPMENT AND INFORMATION SITE LIGHTING: INTERNAL ROADWAYS MUST BE LIGHTED PRIOR TO FIRST C.O. AND THAT ALL ADJACENT ROADWAYS WILL BE REQUIRED TO BE LIGHTED PRIOR TO STREET ACCEPTANCE FOR 1 YEAR WARRANTY. REFER TO SHEET SERIES C5.0 FOR SANITARY SHEETS AND PROFILES. GRAVITY FLOW ANALYSIS: GOODWIN SANITARY SEWER - FRIENDSHIP ROAD (PROPOSED CONDITIONS) TIMMONS GROUP l' t c=FS€J+ .ii rEV I I xJ 1"z h=2Jii5- A B C E F G H I J K L M SSMH NUMBER PIPE SEGMENT MATERIAL PROPOSED DIA. (INCHES) SLOPE (%) MANNIN G (N) % FULL ALLOWABLE ALLOWABLE FLOW (GPM) FULL PIPE (GPM) PROPOSED FLOWS (GPM) Q/Qfull %FULL (GPM) (QIQFuII) MH 1 - MH 3 P-1 PVC 8 1.020% 0.012 50% 297 595 271 0.460 46.0% MH 3 - MH 4 P-3 PVC 8 1.040% 0.012 1 50% 300 600 271 0.450 45.0% MH 4- MH 5 P-4 PVC 8 0.840% 0.012 50% 270 540 271 0.500 50.0% MH 5 - MH 6 P-5 PVC 8 0.840% 0.012 50% 270 540 271 0.500 50.01% MH 6 - MH 7 P-6 PVC 8 0.850% 0.012 50% 271 543 271 0.500 50.0% MH 7 - MH 8 P-7 PVC 8 0.980% 0.012 50% 291 583 271 0.470 47.0% MH 8 - MH 9 P-8 PVC 8 1.000% 0.012 50% 294 589 271 0.460 46.0% MH 9 - MH 10 P-9 PVC 8 1.000% 0.012 50% 294 589 271 0.460 46.0% MH 10 - MH 11 P-10 PVC 8 1.750% 0.012 50% 389 779 271 0.350 35.0% MH 11 - MH 12 P-11 PVC 8 1.600% 0.012 50% 372 745 271 0.360 36.0% ALLOWABLE FLOW =448.8 * (1.49/G) * (AREA @ 50%) *((HYDRAULIC RADIUS @ 500/6)A(2/3)) * J(F) GRAVITY FLOW ANALYSIS: GOODWIN SANITARY SEWER MAIN TRUNK (PROPOSED CONDITIONS) TIMMONS GROUP A B C E F G H I J K L M SSMH NUMBER PIPE SEGMENT MATERIAL PROPOSED DIA. (INCHES) SLOPE (%) MANNING (N) %FULL ALLOWABLE ALLOWABLE FLOW (GPM) FULL PIPE (GPM) PROPOSED FLOWS (GPM) Q/Qfull %FULL (GPM) Q/QFUII MH 1- MH 2 P-1-2 PVC 8 2.2405'. 0.012 50% 441 881 200 0.230 23.09/o MH 2 - MH 3 P-2-3 PVC 8 0.700% 0.012 50% 246 493 200 0.410 41.0% MH 3 - MH 4 P-3-4 PVC 8 0.700% 0.012 50% 246 493 200 0.410 41.0% MH 4 - MH 5 P-4-5 PVC 8 0.700% 0.012 50% 246 493 200 0.410 41.0% MH 5 - MH 6 P-5-6 PVC 8 0.700% 0.012 50% 246 493 200 0.410 41.0% MH 6 - MH 7 P-6-7 PVC 8 1 0.700% 1 0.012 50% 246 493 200 0.410 41.0% MH 7 - MH 8 P-7-8 PVC 8 0.700% 0.012 50% 246 493 241 0.490 49.0% MH 8 - MH 9 P-8-9 I PVC 8 0.700% 0.012 50% 246 493 241 0.490 49.0% ALLOWABLE FLOW =448.8 * (1.49/0 * (AREA @ 50%) *((HYDRAULIC RADIUS @ 50%)A(2/3)) *U(F) GENERAL UTILITY NOTES 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH ALL OSHA REQUIREMENTS AND TOWN OF HOLLY SPRINGS AND NCDOT STANDARDS, SPECIFICATIONS AND DETAILS. 2. INSTALL WATERMAINS WITH A COVER OF NO LESS THAN 4-FT. 3. SANITARY SEWER IMPROVEMENTS ARE TO BE INSTALLED IN ACCORDANCE WITH NCDEQ AND TOWN OF HOLLY SPRINGS REQUIREMENTS (INCLUDING STANDARD DETAILS AND SPECIFICATIONS) 4. ALL SANITARY SEWER SERVICES SHALL BE 4" OR 6" PVC (SCH 40) @1.04% MIN. SLOPE UNLESS INDICATED OTHERWISE. USE DUCTILE IRON WHEN COVER IS LESS THAN 36-IN. 5. CLEANOUTS ARE REQUIRED AT LEAST EVERY 50 FEET FOR FOUR -INCH SEWER SERVICES AND EVERY 100 FEET FOR SIX-INCH SEWER SERVICES AND AT ALL JUNCTIONS AND BENDS WHICH EXCEED 45 DEGREES. BENDS ARE REQUIRED AT ALL CHANGES IN DIRECTION. 6. INSTALL SEWER MAINS WITH A COVER OF NO LESS THAN 36-IN TO FINISH GRADE IN NON -TRAFFIC AREAS, 48-IN TO FINISH GRADE IN TRAFFIC AREAS. 7. SEWER MAINS SHALL BE INSTALLED WITH A MINIMUM VERTICAL CLEARANCE OF 18-IN TO STORM DRAINAGE PIPES. INSTALL ALL UTILITIES TO PROVIDE REQUIRED CLEARANCES AS INDICATED IN THE SPECIFICATIONS. 8. WATERLINES AND SEWER MAINS SHALL BE INSTALLED WITH A MINIMUM HORIZONTAL CLEARANCE OF 10-FT. 9. COORDINATE AND SCHEDULE INSTALLATION OF ALL UTILITIES WITH OTHER PRIME CONTRACTORS, UTILITY COMPANIES AND OTHER TRADES INCLUDING BUT NOT LIMITED TO: NATURAL GAS, ELECTRICITY, TELEPHONE AND CATV. 10. VERIFY EXISTING CONDITIONS AND CONNECTIONS TO EXISTING UTILITIES PRIOR TO CONSTRUCTION. NOTIFY ARCHITECT IF ANY DISCREPANCIES ARE DISCOVERED. 11. CONTRACTOR IS RESPONSIBLE FOR ALL DAMAGES DURING CONSTRUCTION AND SHALL MAKE REPAIRS AT NO EXPENSE TO THE OWNER. 12. THE CONTRACTOR SHALL PROVIDE AN AS -BUILT SURVEY OF ALL UTILITY AND STORM DRAINAGE IMPROVEMENTS FOLLOWING CONSTRUCTION. 13. CONTRACTOR SHALL PHASE DEMOLITION AND NEW CONSTRUCTION TO ENSURE UNINTERRUPTED ACCESS AND UTILITY SERVICE TO ADJACENT FACILITIES. COORDINATE SHORT-TERM, OFF -HOUR, TEMPORARY SHUT- DOWNS WITH THE OWNER. 14. METALLIC LINES SHALL BE IDENTIFIED WITH DURABLE PRINTED PLASTIC WARNING TAPES, MINIMUM 3 INCHES WIDE WITH LETTERING TO IDENTIFY BURIED LINE BELOW. 15. NON-METALLIC PIPES, OTHER THAN GAS LINES, SHALL BE IDENTIFIED BY DETECTABLE WARNING TAPE, MINIMUM 2 INCHES WIDE, WITH LETTERING TO IDENTIFY BURIED LINE BELOW. 16. FOR PLASTIC SEWER PIPING, AN INSULATED COPPER TRACER WIRE OR OTHER APPROVED CONDUCTOR SHALL BE INSTALLED ADJACENT TO AND OVER THE FULL LENGTH OF THE PIPING. ACCESS SHALL BE PROVIDED TO THE TRACER WIRE OR THE TRACER WIRE SHALL TERMINATE AT THE CLEANOUT BETWEEN THE BUILDING DRAIN AND BUILDING SEWER. THE TRACER WIRE SIZE SHALL BE NOT LESS THAN 14 AWG AND THE INSULATION TYPE SHALL BE LISTED FOR DIRECT BURIAL. 17. AN INSULATED COPPER TRACER WIRE OR OTHER APPROVED CONDUCTOR SHALL BE INSTALLED ADJACENT TO UNDERGROUND NONMETALLIC PIPING. ACCESS SHALL BE PROVIDED TO THE TRACER WIRE OR THE TRACER WIRE SHALL TERMINATE ABOVEGROUND AT THE END OF THE NONMETALLIC PIPING. THE TRACER WIRE SIZE SHALL NOT BE LESS THAN 18AWG AND THE INSULATION TYPE SUITABLE FOR DIRECT BURIAL. 18. ALL GATE VALVES NOT IN PAVEMENT REQUIRE A CONCRETE COLLAR. 19. GATE VALVES SHALL NOT BE INSTALLED IN GUTTER PAN. 20. UTILITIES CONTRACTOR TO NOTIFY INSPECTOR AT LEAST 48 HOURS BEFORE FLUSHING THE PROPOSED WATERLINE. 21. ALL EXISTING UTILITIES, SUCH AS VALVE BOXES, VAULT COVERS, AND MANHOLES, AFFECTED BY GRADING OR PAVING OPERATIONS MUST BE ADJUSTED TO FINAL GRADE AFTER CONSTRUCTION. 22. REFER TO PLUMBING DRAWINGS FOR SANITARY SEWER INVERTS OUT OF BUILDINGS 23. FIRE MARSHALL SHALL BE PRESENT ONSITE DURING WATER MAIN SHUTDOWN ON SCHOOL SITE. 24. FENCE POSTS SHALL NOT BE LOCATED WITHIN UTILITY EASEMENTS. 25. ALL NEW UTILITY LINES (POWER, CABLE, ETC.) MUST BE UNDERGROUND. 26. ALL CONSTRUCTION SHALL CONFORM TO THE TOWN OF HOLLY SPRINGS DESIGN AND CONSTRUCTION STANDARDS. 27. CONSTRUCTION DRAWING APPROVAL IS REQUIRED PRIOR TO BEGINNING CONSTRUCTION. DEVELOPMENT FEES (ACREAGE, FEE -IN -LIEU OF ASSESSMENT AND INSPECTION FEES AND OTHERS AS REQUIRED MAY BE APPLICABLE) ARE DUE BEFORE CONSTRUCTION DRAWING APPROVAL. 28. THE ESTIMATED SEWER FLOWS SHOWN ARE BASED ON ASSUMED TENANT MIX AT THE TIME OF THE SUBMITTAL. THE ESTIMATED FLOWS WILL BE UPDATED WITH EACH DEVELOPMENT PLAN SUBMITTAL. 29. THE PLAN IS SUBJECT TO REVISIONS DURING CONSTRUCTION DRAWING APPROVAL PROCESS. 30. REFER TO C0.1 FOR ZONING CONDITIONS IN THE DEVELOPMENT AGREEMENT. 31. THE MONUMENT CONTROL POINTS FOR THIS PROJECT IS: TOWN OF HOLLY SPRINGS GEODETIC MONUMENT "ALFORD 33" PUBLISHED COORDINATES N=693,650.75' E=2,041,575.85' ELEV.=377.10'. THE TOWN OF HOLLY SPRINGS HAS INSTALLED A LOCAL GEODETIC MONUMENTATION GRID, TIED TO NAD83, WITHIN AND SURROUNDING THE TOWN LIMITS. ALL SURVEYED INFORMATION (WHEN ANY PORTION OF THE PROJECT IN DESIGN IS WITHIN 2000 FEET OF THE TOWN'S GEODETIC MONUMENT) SHALL REFERENCE THE NEAREST MONUMENT AND SHALL BE CLEARLY NOTED ON THE FIRST SHEET OF, BOTH CONSTRUCTION PLANS, AND AS-BUILTS SUBMITTED TO THE TOWN. 32. IF THERE IS A GEODETIC MONUMENT LOCATED ON THIS SITE, IT MUST BE PROTECTED OR IF RELOCATION IS NEEDED IT WILL BE THE RESPONSIBILITY OF THE DEVELOPER TO RELOCATE IT WITH SURVEY ACCURACY. 33. INTERNAL ROADWAYS MUST BE LIGHTED PRIOR TO FIRST C.O. AND THAT ALL ADJACENT WILL BE LIGHTED PRIOR TO STREET ACCEPTANCE FOR 1 YEAR WARRANTY. 34. BLOW OFF VALVES ARE REQUIRED AT ALL AREAS WHERE THE UTILITY MAINS STOP AND/OR WILL BE EXTENDED IN THE FUTURE. 35. ALL BENDS SHOWN ON PLANS ARE HORIZONTAL BENDS UNLESS OTHERWISE NOTED. PIPES SHALL BE DEFLECTED PER MANUFACTURER'S STANDARDS. EASEMENTS: 1. WATER AND SANITARY SEWER MAINS SHALL BE LOCATED IN A 20' WIDE PUBLIC UTILITY EASEMENT. IN THE CASE OF UTILITES EXTENDING ADJACENT TO EACH OTHER THE EASEMENT MAY BE A VARIABLE WIDTH EASEMENT BUT NO LESS THAN 10' FROM EACH UTILITY LINE. WATER SERVICES UP TO THE METER AND FIRE HYDRANT ASSEMBLIES SHALL BE LOCATED IN A 10' WIDE PUBLIC UTILITY EASEMENT. SEE UTILITY PLANS FOR LOCATIONS OF EASEMENTS. 2. ALL PRIVATE STORM DRAINAGE PIPE WITH THE EXCEPTION OF SERVICE LINES TO BUILDINGS SHALL BE LOCATED IN A 20' PRIVATE STORM DRAINAGE EASEMENT. SEE GRADING AND STORM DRAINAGE PLANS FOR LOCATION OF EASEMENTS. 3. ANY STORM DRAINAGE PIPE EXTENDING FROM A PUBLIC RIGHT-OF-WAY INTO THE SITE SHALL BE LOCATED IN A 20' PUBLIC STORM DRAINAGE EASEMENT. LEGEND: POD BOUNDARY PROPERTY BOUNDARY PHASEIBOUNDARY PHASE II BOUNDARY �aoa6� k � CAR°�o �° o0 o �sj* ssS10% o0 o � i'7 q ; �' SEAL 3474 Q ; I I o 3 2 Gc) 22 3�Yn'�!; 0 U I'D 0 � o N w U z 4- ~ 3 a 3 0 U 0 N ILL-i O- U. N � �OoM a m -1 c� 0 °'ui J x <� ebLL 0 �-i LO T Ln rn L �� o � LLn rn J w U) U) U) U) U) z z z z z w w w w w O 0000 0 Cl_ UUUU U z z z z z w 0000 0 z w w w w w O Cl. Cl. Cl. Cl. Cl. U) U)U)U)U) U) z z z z z w 0000 0 V7 V7 V7 V7 V7 > > > > > rr) rr) rr) ry) ry) N N N N N w o 0 0 0 0 N N N N N Q o ,-I N rr) rr) 0 rr) ,-I N ,-I o �C) 00 rn o DATE 0511912023 D RAW N BY T. MORRISO/V DESIGNED BY B. MCLAMB CHECKED BY B HALL SCALE AS SHOWN 30B NO. 54318 SHEET NO. C4.0 a - t O _Os - o 0- c: >T c a O U c � a c O � U O L �� 0 U) c z O g c F- 0 o T C .� O L U U 0 O L o_ c > O U U a O x � E o O ,n c a L U N o > a) tb O a Ln L \ \ SCALE 1 "=40' �� i , i ✓ \ \ \ I \ \ \ - ✓ A \v z EER m \ \ / A / \V / I �\ \ �V A A— \ \ 0 40' 80' \ \ 1 340 \ \ \ \ EX STREAM > �— / I v \✓\ I v v v✓ A ��� z \ \ / / G) \ A \ \ \ W 30 CAPE FEAR RAM UFFER _ / \ W \ I ( ti` n� \ \ i �\ V �� �— A / / A \ \ V A� ✓ A \ v �—�A\ f v \ �� _ 77— 307 J'ro\ \ \ /�) 30.9 �--- v VA l �� V A \ �� ✓ 1 \ \ / \ ✓ A \ V A v \ 315 - - - - - - - - - / \ �� 1 - - -12"x6"TEE&3 - - - _- GATE VALVES 1 \ I _ / L� r.�J- -/_ - RPLE PVC i _ _ -_- _ --317- _ - - - - - - - - - - - -_ TEMPORARY 2" BLOW -OFF ASSEMBLY�� RECLAIMED WATERLINE - - - - - _ - - - _ _ - - - -- _ - _ -_ - C11 V�t 1 _c— -- - — — — — — — - IV 7- -- 357- - WOODS CREEK RD. 1 / — — — _ i — _ _ �A� _ v _ =�✓ — — — — _ _ \ \ - —-- � _ —_ — _— � / / ! /1— �_"_"T` '�- =- �----�= -- J � � J / ( � / � i ( l / / � � � \ �\ \ � -- � _- "- �_S" _��r1T � � (ill/I((/_�,-/ �`/ J / ✓ ( / I �1\✓ r pp 4 W 16"Ip/�/41 o-D �: 350 345 340 335 330 325 320 315 310 305 G _-- G G G - G -20' TOHS WATERLINE EASEMENT 10' GAS EASEMENT G J� 3 MATCHLINE REFER TO DRAWING C4.5 RECLAIMED WATERLINE PLAN VIEW TEM ORARY 2" BLOW -OFF SSEMB Y \ /` E (IS TING GRADE \ \ \ TA 14+5 .13 4.50'Mlll COVE 12" GATE VA TA 14+5 .16 STA 14 62.15 4 O N N m co M� co Lo pp N rf co d M� co 00 M 00 ri co d M� co O N Lo d M� co co M� co r- �i co� M� co Lo 00 M r� Mai MM co (O O (6 M00 MM co co Lo (�� MM co O h N M Mari MM M N 00 Oo M� MM M co � o Mco MM co Lo O O a� co M (O 0) • N, coN� co M 00 �— N cfl coNo Nao MN co O �i N� MN M N O rf Nco co (''•)N M � N N�ri MN co M M N� MN co co N M o Nco MN co co �cq MN co co O ao .,� MN co co O MN co N M co MN co 00 o co co MN O o � MN co 00 O cfl o � M M co N 00 co ai � M M Lo cfl ai � M M N 0p co ai � M co O N� 00 ai � co M O ai � co MN 0 N o co M 350 345 340 335 NOTES: 1. PIPE LENGTHS IN PROFILES ARE ACTUAL PIPE LENGTHS FROM CENTER TO CENTER OF STRUCTURE. PIPE LENGTHS IN DRAINAGE DESCRIPTIONS ARE PIPE LENGTHS AS MEASURED IN PLAN VIEW FROM CENTER TO CENTER OF STRUCTURE. KEY C/L EX. GRADE---------- C/L FINAL GRADE 330 REFER TO GOODWIN PUMP LEGEND STATION FOR SITE PLAN DEVELOPMENT AND PHASE I BOUNDARY LINE INFORMATION PHASE II BOUNDARY LINE 325 320 315 310 305 300 to 40 RDFILE SCALE M 9+80 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 WOODS CREEK ROAD RECLAIMED WATERLINE PROFILE - STA 9+80 TO 18+00 Horz: 1" = 40' Vert: 1" = 4' UTILITY NOTES: 1. ALL CONSTRUCTION WILL BE TO TOWN OF HOLLY SPRINGS OR NCDOT STANDARDS, SPECIFICATIONS, AND DETAILS. 2. ALL DRIVEWAYS MUST BE INSTALLED TO THE MINIMUM TOWN OF HOLLY SPRINGS OR NCDOT STANDARDS. 3. ALL PROPOSED BUILDINGS, VEHICULAR AREAS, PEDESTRIAN AREAS, SIGNAGE AND LANDSCAPING WILL MEET TOWN ARCHITECTURAL AND SITE DESIGN REQUIREMENTS, AS WELL AS THE DESIGN GUIDELINES THAT ACCOMPANY THE MASTER PLAN. WHERE THESE ARE NOT MET, WAIVERS WILL BE SUBMITTED FOR APPROVAL AT TIME OF THE DEVELOPMENT PLAN. 4. WHERE SIDEWALK IS PROPOSED AT THE BACK OF CURB SIDEWALK SHALL BE A MINIMUM OF 6' WIDE. 5. DOUBLE WHEELCHAIR RAMPS ARE TO BE INSTALLED AT ALL PUBLIC STREET INTERSECTIONS WHERE SIDEWALK IS REQUIRED. WHEN SIDEWALK IS NOT REQUIRED, CURB IS TO BE DEPRESSED AT ALL RAMP LOCATIONS. 6. ALL STREETS SHOWN ON THESE PLANS SHALL HAVE THE FULL WIDTH OF RIGHT-OF-WAY CLEARED AND GRUBBED WITHIN 50' OF ALL STREET INTERSECTIONS. 7. NO SIGHT OBSTRUCTINGS OR PARTIALLY OBSTRUCTING WALL, FENCE, FOLIAGE, BERM, SIGN, PARKED VEHICLE, OR OTHER OBJECTS BETWEEN THE HEIGHTS OF TWO FEET AND EIGHT FEET ABOVE THE CURB LINE ELEVATION (OR THE EDGE OF PAVEMENT IF NO CURB EXISTS) SHALL BE PLACED WITHIN SIGHT DISTANCE TRIANGLE. 8. THE PROJECT DEPENDS ON THE NECESSARY UTILITIES AND RELATED INFRASTRUCTURE FOR WATER SERVICE BEING FINISHED. IF ANY OFF -SITE WATER FACILITIES REQUIRED TO SERVE THIS PROJECT ARE NOT FINISHED AND ACCEPTED BY THE TOWN WHEN THIS PRELIMINARY SUBDIVISION PLAN IS APPROVED, THEN THESE FACILITIES MUST BE FINISHED PRIOR TO CONSTRUCTION DRAWING APPROVAL, UNLESS THE ADMINISTRATOR GRANTS AN EXCEPTION. 9. ALL BENDS SHOWN ON PLANS ARE HORIZONTAL BENDS UNLESS OTHERWISE NOTED. PIPES SHALL BE DEFLECTED PER MANUFACTURER'S STANDARDS. EASEMENTS: 1. WATER, RECLAIM WATER, AND SANITARY SEWER MAINS SHALL BE LOCATED IN A MIN. 20' WIDE PUBLIC UTILITY EASEMENT OR DECICATED R/W. IN THE CASE OF UTILITIES EXTENDING ADJACENT TO EACH OTHER THE EASEMENT MAY BE A VARIABLE WIDTH EASEMENT BUT NO LESS THAN 10' FROM EACH UTILITY LINE. WATER SERVICES UP TO THE METER AND FIRE HYDRANT ASSEMBLIES SHALL BE LOCATED IN A 10' WIDE PUBLIC UTILITY EASEMENT. SEE UTILITY PLANS FOR LOCATIONS OF EASEMENTS. 2. ALL PRIVATE STORM DRAINAGE PIPE WITH THE EXCEPTION OF SERVICE LINES TO BUILDINGS SHALL BE LOCATED IN A 20' PRIVATE STORM DRAINAGE EASEMENT. SEE GRADING AND STORM DRAINAGE PLANS FOR LOCATION OF EASEMENTS. 3. ANY STORM DRAINAGE PIPE EXTENDING FROM A PUBLIC RIGHT-OF-WAY INTO THE SITE SHALL BE LOCATED IN A 20' PUBLIC STORM DRAINAGE EASEMENT. Qo���60f1���OQpO C AROssill TT q sAL! c O a 34�74 a Q ; If 03 22 a 2233�; o .. IiV sT i� -ropo 0 U 0 � o N E LA U z }: ~ _ 3 a 3 0 U o N �LL_-i W N w p o M ax -'0� cM w 0 0 c)(-i m rn L �� o � Ln rn J w U) U) U) U) U) z z z z z w w w w w 0 0000 0 a U U U U U z z z z z W O O O O O W W W W W O a a a a a U) U) U) U) U) U) z z z z z w 0 0 0 0 0 U) U) U) U) U) > > > > > rorororo ro N N N N N W O O O O O N N N N N Q O \i N m m to 00 0) O i DATE 0511912023 D RAW N BY T. MORRISO/V DESIGNED BY B. MCLAMB CHECKED BY B HALL SCALE AS SHOWN 30B NO. 54318 SHEET NO. C4.2B D a� N �z 0 o c � a t o T c aC o C U c a c o D U o L �� 0 U Ccz 0 m 6 �s �0 o T c .� 0 L U U 0 L o— c o •� U a o x a� � t F •J - 0 0 9) L I EASEMENTS: m y 1. WATER, RECLAIM WATER, AND SANITARY SEWER MAINS SHALL BE m — _ LOCATED IN A MIN. 20' WIDE PUBLIC UTILITY EASEMENT OR DECICATED —_-� ____—= J� / _ ___— �� __ _ — _____— —— --_ _--_--_—_ _— ___ ___ ___ ____ RAN. INTHE CASE OFUTILITIES EXTENDING ADJACENT TOEACH OTHER = 0 z _ _ _ _ _ — - - _ _ - —_ — - _ __ __ = -- _ -_ — -- — — THE EASEMENT MAY BE A VARIABLE WIDTH EASEMENT BUT NO LESS _ — --- _--- m _ — J — \ ----------- --_--- —_ — —------- — - -- — — — _ —, , = y� I �/` (/ I / I ^ > / \ \ / / / — — _ _ _ _ _ _— _ — — _ _ _ _ _ _ — — _ THAN 10 FROM EACH UTILITY LINE. WATER SERVICES UP TO THE METER _ — D — — — — �� f \ ( / / / l / / \ \ — — _ _ — — _ — — — — — — — _ _ _ _ — — V AND FIRE HYDRANT ASSEMBLIES SHALL BE LOCATED IN A 10 WIDE — PUBLIC UTILITY EASEMENT. SEE UTILITY PLANS FOR LOCATIONS OF EASEMENTS. r � / / / / 2. ALL PRIVATE STORM DRAINAGE PIPE WITH THE EXCEPTION OF SERVICE _ LINES TO BUILDINGS SHALL BE LOCATED IN A 20' PRIVATE STORM LA DRAINAGE EASEMENT. SEE GRADING AND STORM DRAINAGE PLANS FOR LOCATION OCATION /O/ / F EASEMENTS. 3ANY STORM DRAINAGE PIPE \ \ I\I I \\ I \EXTENDING AI\\ I V \�\F\\RA \\OIV \ M\V \ \A \\ A A PUBLIC UBLIC RIGHT-OF-WAY INTO THE SITE SHALL BE LOCATED IN A 20'PUBLIC STORM DRAINAGE r EASEMENT. < In L � TIE TO EX. RECLAIMED WATERLINE w/ TEMPORARY 2" PVC BLOW -OFF ASSEMBLY 12" PURPLE 317— RECLAIMED WATERLIN5� 1925+5075/ 1 R --— — � q7, 13 i G1 G 0314/ E \\\ vv \ \ \ �OH WATERLINE EASEMENT 30 EX\STREAAM_ 305 30' CAPE FEAR STREAM BUFFER 340 335 330 325 320 315 310 305 POD C 12.61AC 11=40'I RECLAIMED WATERLINE PLAN VIEW PROPOSED GRADE \ -� EXl TING GRAD E i 2" PURPLE PVC 12" GATE VALVE 12" PURPLE PVC SEPARATION INV: 31 .05 N o0o I� m co M M N� M O M M �� O O ' M M M� N co O N M co NM O O M M �� O N M co N� (0 o N M M N� co N N N M M �N O M N N N M O rt� M cn N N M M �M M �f N N M M MO O � N N M M O oa' I� K N N M M mM M N N M M oo� M ao O N N M M m`n O � M N M M �� o M M M M M uo� � N M M M M mac° M N M M M M �� O 1 N M M M M �N 00 �'� � M coM co M oM co M co co M o� O (n M M co M N°O O rr M M co M o� 00 O �f M M co M MM rr M M M M N� N �r M M co M �� N '6 M M co M oN I� O N M M co M oa' ni M M M M O w M M M M c) M M o M ao N � N 340 335 33 325 320 315 310 305 4 TIE INTO EXISTING 12" RECLAIMED WATERLINE 0 40 PROFILE SCALE NOTES: 1. PIPE LENGTHS IN PROFILES ARE ACTUAL PIPE LENGTHS FROM CENTER TO CENTER OF STRUCTURE. PIPE LENGTHS IN DRAINAGE DESCRIPTIONS ARE PIPE LENGTHS AS MEASURED IN PLAN VIEW FROM CENTER TO CENTER OF STRUCTURE. KEY C/L EX. GRADE - - - - - - - - - - C/L FINAL GRADE REFER TO GOODWIN PUMP LEGEND STATION FOR SITE PLAN PHASE I BOUNDARY LINE DEVELOPMENT AND INFORMATION PHASE II BOUNDARY LINE UTILITY NOTES: 1. ALL CONSTRUCTION WILL BE TO TOWN OF HOLLY SPRINGS OR NCDOT STANDARDS, SPECIFICATIONS, AND DETAILS. 2. ALL DRIVEWAYS MUST BE INSTALLED TO THE MINIMUM TOWN OF HOLLY SPRINGS OR NCDOT STANDARDS. 3. ALL PROPOSED BUILDINGS, VEHICULAR AREAS, PEDESTRIAN AREAS, SIGNAGE AND LANDSCAPING WILL MEET TOWN ARCHITECTURAL AND SITE DESIGN REQUIREMENTS, AS WELL AS THE DESIGN GUIDELINES THAT ACCOMPANY THE MASTER PLAN. WHERE THESE ARE NOT MET, WAIVERS WILL BE SUBMITTED FOR APPROVAL AT TIME OF THE DEVELOPMENT PLAN. 4. WHERE SIDEWALK IS PROPOSED AT THE BACK OF CURB SIDEWALK SHALL BE A MINIMUM OF 6' WIDE. 5. DOUBLE WHEELCHAIR RAMPS ARE TO BE INSTALLED AT ALL PUBLIC STREET INTERSECTIONS WHERE SIDEWALK IS REQUIRED. WHEN SIDEWALK IS NOT REQUIRED, CURB IS TO BE DEPRESSED AT ALL RAMP LOCATIONS. 6. ALL STREETS SHOWN ON THESE PLANS SHALL HAVE THE FULL WIDTH OF RIGHT-OF-WAY CLEARED AND GRUBBED WITHIN 50' OF ALL STREET INTERSECTIONS. 7. NO SIGHT OBSTRUCTINGS OR PARTIALLY OBSTRUCTING WALL, FENCE, FOLIAGE, BERM, SIGN, PARKED VEHICLE, OR OTHER OBJECTS BETWEEN THE HEIGHTS OF TWO FEET AND EIGHT FEET ABOVE THE CURB LINE ELEVATION (OR THE EDGE OF PAVEMENT IF NO CURB EXISTS) SHALL BE PLACED WITHIN SIGHT DISTANCE TRIANGLE. 8. THE PROJECT DEPENDS ON THE NECESSARY UTILITIES AND RELATED INFRASTRUCTURE FOR WATER SERVICE BEING FINISHED. IF ANY OFF -SITE WATER FACILITIES REQUIRED TO SERVE THIS PROJECT ARE NOT FINISHED AND ACCEPTED BY THE TOWN WHEN THIS PRELIMINARY SUBDIVISION PLAN IS APPROVED, THEN THESE FACILITIES MUST BE FINISHED PRIOR TO CONSTRUCTION DRAWING APPROVAL, UNLESS THE ADMINISTRATOR GRANTS AN EXCEPTION. 9. ALL BENDS SHOWN ON PLANS ARE HORIZONTAL BENDS UNLESS OTHERWISE NOTED. PIPES SHALL BE DEFLECTED PER MANUFACTURER'S STANDARDS. C Aj�OTT o C) �'Osssj"o, o q SEAL! 40 O a 34�74 a al; Il 03 2o23 0 U 0 N LuU z }: a 3 0 U N <LL—� a LL N LuOoM ax -'00 Ln J x c� �LL 0 0 L T cm, rn _ E'Q: L �� oM Ln rn J L F— U) U) U) U) U) z z z z z LLJ Lu Lu Lu Lu O 0 0 0 0 0 a U U U U U z z z z z uu L 0000 0 C) L L L L L O a a a a a U7 U7 U7 U7 U7 z z z z z w 0 0 0 0 0 U) U) U) U) U) Lu Lu Lu Lu Lu rr) rr) rr) rr) rr) N N N N N C) C) C) CD CDLu N N N N N 0 (r) , -i N , -i O 1,0 00 0) O i DATE 0511912023 D RAW N BY T. 1VORRISO/V DESIGNED BY B. MCLAMB CHECKED BY B HALL SCALE AS SHOWN Hq Hq cz I..L LL U uz J LL 0 z Uo� u Lu 2 Z = O W 00 zLu CW G Lu J U WA' V ol uz 0 0 V 30B NO. 54318 SHEET NO. C4.3B L Q D 0 a� N �z 0 o ,:2 F- a - t o Q1 .� a o .� C T c a o U c a c D U o L C0 lil o z 0 �-0 o T C .� o L U U 0 O L o c o •� U O o U — X-0 a� � t •J 0 0 c � L U O N tb O O O 17+00 17+50 18+00 18+50 19+00 19+50 20+00 20+50 21+00 21+50 22+00 22+50 lA►nnne 9-DEC1[ onAn D=rll AIMGn IAIATGRI IMF PRnFII F _ STD 17+00 TO 25+75 L 23+00 23+50 24+00 24+50 25+00 25+50 25+75 / I _ — < < \ \ m > / �s / EASEMENTS: o00 0� / �_ �-- I ' �( / / o / — _ I� ( 1 \ \ \ m ��a ���/ \ / 1. WATER, RECLAIM WATER, AND SANITARY SEWER MAINS SHALL BE / / — r n �� �•au.. if �o i \ > \ \ � z 1 \\\ \ \ L o r — ����� — — / — 7 ( LOCATED IN A MIN. 20 WIDE PUBLIC UTILITY EASEMENT OR DECICATED o �.�,S5 j©•�� O z j ��� �� / r RAN. IN THE CASE OF UTILITIES EXTENDING ADJACENT TO EACH OTHER THE EASEMENT MAY BE A VARIABLE WIDTH EASEMENT BUT NO LESS • `� SEAL • o a a ,� , — � � THAN 10' FROM EACH UTILITY LINE. WATER SERVICES UP TO THE METER o • o r / / _ A z / /�/�%�/ / r \ V AND FIRE HYDRANT ASSEMBLIES SHALL BE LOCATED IN A 10' WIDE o I1 032 023 IF -1 / > / / / / /� V A ( 1 \ o o / / V O / //��/�/ / / / ( 1 ) PUBLIC UTILITY EASEMENT. SEE UTILITY PLANS FOR LOCATIONS OF EASEMENTS. o '• . •'o 2. ALL PRIVATE STORM DRAINAGE PIPE WITH THE EXCEPTION OF SERVICE C��'d L o LINES TO BUILDINGS SHALL BE LOCATED IN A 20 PRIVATE STORM �aD a Q uQ DRAINAGE EASEMENT. SEE GRADING AND STORM DRAINAGE PLANS FOR LOCATION OF EASEMENTS. z 3. ANY STORM DRAINAGE PIPE EXTENDING FROM A PUBLIC RIGHT-OF-WAY ,( \ �( \ ) / INTO THE SITE SHALL BE LOCATED IN A 20 PUBLIC STORM DRAINAGE C M \\ (\���/ 1 v ll� v J EASEMENT. o E 6" PURPLE PVC � / w RECLAIMED WATERLINE \ L _-----/ / —_/ / M \ \ (�/A\V� �� �� /�i� _\_— A 0 LLI ro �/ ✓V A �� �� —— F — / — / — / / O - — — — — W U N z z z z z ¢ co z 2: 2: 2: 2: 2: �, wp c� O L / ' 11.25' BEND MINIMUM 2' SEPARATION / / — — � a z o 0000 O —� _� / — a UUUU U < —� l 6 X6 TEE &3 z W moo, a z z z z z \ --� GATE VALVES 11.25 BEND - �� s — � �n U � � � � � MINIMUM 2 SEPARATION TEMPORARY / / — — — x U) -- — d¢ W OOOO O BLOW -OFF VALVE � — — — / / � — o 12+ Lr) ��n z WWWW W r� O a a a a a ( �� / /� (� �� ��z E� L� < l \ / /. 1fL �� 1 /S �� — �ti /� / ��r �� z z z z z U7 U7 U7 U7 U7 > � A 1/ ��— •• o�� —i \ 1 �� >> >> w W W W W W �� s / �� ; / A A 3Q CAPE FEAR STREAM BUFFEf� , .-� � _/ice �3 0 / /STREAM � � ♦ � � —__—� / l 299 / / l / > \, 305 s —_�/ V / / j� ( ( ( ( / / / l l ♦ — �-��/ 10 MIN. MAINTENANCE s s / ( / &ACCESS EASEMENT J T 7v / / (/ / / ♦ / ✓/ vy ay r I / / /� /J �/ j ♦ / ��� \ /�iiv \� N i \ � 1� / i /lb i �� ��A( �� — `� / /� �� / / /( / \ ��/ �/ t/lll / / /� / �/ `b l l �' SCM B SCALE 1 "=40' / / 0 40' 80' RECLAIMED WATERLINE PLAN VIEW 320 315 310 305 295 290 C M ' EXISTING GRADE � PROPOSED GRAD 6' GATE VALVE 11.25' BEND STA 10+04. 2 . 0' MIN. COVER STA TEE 14+87.5 6" PURPLE RE \ " PVC (FM) 1.50' MIN. SEPARATION 215 15" RCP I STRM `PVC BEND 05 11.25 STA 12+52.35 — - IN :298.47 \ 24' RCP STIRM RATION SEP I N pp (o N M � � (O N M M CDM N M M M O pp O M M M N*pp N M M M M O � O O M M CO C) 7 O O co I- LO O O C)O co M O (0 O O O O co N � I- M O O co I- Ln `* M O co coN N M O CDCDCDCD co N 0)N CD M O O co M I� O M O O co co � N M O M M I� M M O CD M c") 9+80 10+00 10+50 11+00 11+50 12+00 12+50 13+00 ACCESS ROAD B RECLAIMED WATERLINE PROFILE - STA 9+80 TO 14+00 320 NOTES: 1. PIPE LENGTHS IN PROFILES ARE ACTUAL PIPE LENGTHS FROM CENTER TO CENTER OF STRUCTURE. PIPE LENGTHS IN DRAINAGE DESCRIPTIONS ARE PIPE LENGTHS AS MEASURED IN PLAN VIEW FROM CENTER TO CENTER OF STRUCTURE. KEY C/L EX. GRADE---------- C/L FINAL GRADE REFER TO GOODWIN PUMP LEGEND 315 STATION FOR SITE PLAN DEVELOPMENT AND PHASE I BOUNDARY LINE INFORMATION PHASE II BOUNDARY LINE 310 305 300 295 290 C'7 o6 O C'7 13+50 14+00 4 UTILITY NOTES: 1. ALL CONSTRUCTION WILL BE TO TOWN OF HOLLY SPRINGS OR NCDOT STANDARDS, SPECIFICATIONS, AND DETAILS. 2. ALL DRIVEWAYS MUST BE INSTALLED TO THE MINIMUM TOWN OF HOLLY SPRINGS OR NCDOT STANDARDS. 3. ALL PROPOSED BUILDINGS, VEHICULAR AREAS, PEDESTRIAN AREAS, SIGNAGE AND LANDSCAPING WILL MEET TOWN ARCHITECTURAL AND SITE DESIGN REQUIREMENTS, AS WELL AS THE DESIGN GUIDELINES THAT ACCOMPANY THE MASTER PLAN. WHERE THESE ARE NOT MET, WAIVERS WILL BE SUBMITTED FOR APPROVAL AT TIME OF THE DEVELOPMENT PLAN. 4. WHERE SIDEWALK IS PROPOSED AT THE BACK OF CURB SIDEWALK SHALL BE A MINIMUM OF 6' WIDE. 5. DOUBLE WHEELCHAIR RAMPS ARE TO BE INSTALLED AT ALL PUBLIC STREET INTERSECTIONS WHERE SIDEWALK IS REQUIRED. WHEN SIDEWALK IS NOT REQUIRED, CURB IS TO BE DEPRESSED AT ALL RAMP LOCATIONS. 6. ALL STREETS SHOWN ON THESE PLANS SHALL HAVE THE FULL WIDTH OF RIGHT-OF-WAY CLEARED AND GRUBBED WITHIN 50' OF ALL STREET INTERSECTIONS. 7. NO SIGHT OBSTRUCTINGS OR PARTIALLY OBSTRUCTING WALL, FENCE, FOLIAGE, BERM, SIGN, PARKED VEHICLE, OR OTHER OBJECTS BETWEEN THE HEIGHTS OF TWO FEET AND EIGHT FEET ABOVE THE CURB LINE ELEVATION (OR THE EDGE OF PAVEMENT IF NO CURB EXISTS) SHALL BE PLACED WITHIN SIGHT DISTANCE TRIANGLE. 8. THE PROJECT DEPENDS ON THE NECESSARY UTILITIES AND RELATED INFRASTRUCTURE FOR WATER SERVICE BEING FINISHED. IF ANY OFF -SITE WATER FACILITIES REQUIRED TO SERVE THIS PROJECT ARE NOT FINISHED AND ACCEPTED BY THE TOWN WHEN THIS PRELIMINARY SUBDIVISION PLAN IS APPROVED, THEN THESE FACILITIES MUST BE FINISHED PRIOR TO CONSTRUCTION DRAWING APPROVAL, UNLESS THE ADMINISTRATOR GRANTS AN EXCEPTION. 9. ALL BENDS SHOWN ON PLANS ARE HORIZONTAL BENDS UNLESS OTHERWISE NOTED. PIPES SHALL BE DEFLECTED PER MANUFACTURER'S STANDARDS. rr) rr) rr) rr) rr) N N N N N 0 0 0 0 0 W N N N N N ¢ �0 00 .� DATE 0511912023 D RAW N BY T. MORRISO/V DESIGNED BY B. MCLAMB CHECKED BY B HALL SCALE AS SHOWN H4 H4 cz I..L ■ LL U) zLij H� u_ 0 z U ' U W = L = O W 00 zwo CW G J Q Lu J U W uz 0 0 V 30B NO. 54318 SHEET NO. C4.4B L Q a — t o Q1 0 a o — c U) >T c aC o C U c C) c O D U o L C� U) c z 0 �-0 o T C .� o L U U 0 o L a� c > o U a o U — x U a� � t F •J — 0 0 C a L U > o > a� o C) 0) Horz: 1" = 40' Vert: 1" = 4' L 0 40 PROFILE SCALE MATCH LINE REFER TO DRAWING C4.3 1q 4- 12"1TEE &3� I -- \ (✓/,�/� -r =_� GATE VALVES �/ I J<r�J I i /- �/X� I bH J /I r 61 325 320 315 310 305 300 295 290 i Ih I IIA,,r I LI , I IIII I�� �1 317 lml_ :�.:. Pit UTILITY NOTES: 1. ALL CONSTRUCTION WILL BE TO TOWN OF HOLLY SPRINGS OR NCDOT AR-S\l EAIVI\BIJ� C\\ \ II STANDARDS, SPECIFICATIONS, AND DETAILS. - \ \ \ \ I 2. ALL DRIVEWAYS MUST BE INSTALLED TO THE MINIMUM TOWN OF HOLLY �� \ SEC FEE I r1 ♦ \ \ \ \ \ \ \ \ \ \\�\� \ / � \����\), \ J //j /,� �/_ -� -� \ �III� ((( �\\ SPRINGS OR NCDOT STANDARDS. II1 I 1 3. ALL PROPOSED BUILDINGS, VEHICULAR AREAS, PEDESTRIAN AREAS, ♦ ` \ \ \ \ \ \\ \ \ I \� I \ \ ` �\ 1\ SIGNAGE AND LANDSCAPING WILL MEET TOWN ARCHITECTURAL AND SITE ♦ \ \ I \ \ I 1 I �\ I j)j� �, _ ! \ - \\ \ 1 I�L� DESIGN REQUIREMENTS, AS WELL AS THE DESIGN GUIDELINES THAT ♦ \ \ \ I I ` \ / / 1 I I ( )/`/ r�i �_% \�y// 1 \ ��_ J �i /�//\I� ACCOMPANY THE MASTER PLAN. WHERE THESE ARE NOT MET, WAIVERS JJ/ WILL BE SUBMITTED FOR APPROVAL AT TIME OF THE DEVELOPMENT I I 1 l l III lI t4 ��� ` �� / /� JJ�•" �,05 3 \ \\\ �I /� J I / -\ ♦ I ) I o I I I I / \ /��� %/� // _ ' Og` /( PLAN. g 4. WHERE SIDEWALK IS PROPOSED AT THE BACK OF CURB SIDEWALK SHALL ♦ < / I I I 1 �J I % - // / / // p \ \ ( BE A MINIMUM OF 6' WIDE. /1 \ \ \ \ I / \ \ 5. DOUBLE WHEELCHAIR RAMPS ARE TO BE INSTALLED AT ALL PUBLIC / • / / / % ) / I I I I 11��� / / //) '� i /// / , /� Q- \ \ \/n\ STREET INTERSECTIONS WHERE SIDEWALK IS REQUIRED. WHEN SIDEWALK IS NOT REQUIRED, CURB IS TO BE DEPRESSED AT ALL RAMP LOCATIONS. 6. ALL STREETS SHOWN ON THESE PLANS SHALL HAVE THE FULL WIDTH OF RIGHT-OF-WAY CLEARED AND GRUBBED WITHIN 50' OF ALL STREET INTERSECTIONS. 7. NO SIGHT OBSTRUCTINGS OR PARTIALLY OBSTRUCTING WALL, FENCE, I / '� I I I ( / °' ✓ ) I % ` / \ I FOLIAGE, BERM, SIGN, PARKED VEHICLE, OR OTHER OBJECTS BETWEEN 11.25° BEND /j I 1 / / / ` / o^o / / I ` \ I I ` \\\ THE HEIGHTS OF TWO FEET AND EIGHT FEET ABOVE THE CURB LINE / � (/ \ \ \\ ELEVATION (OR THE EDGE OF PAVEMENT IF NO CURB EXISTS) SHALL BE PLACED WITHIN SIGHT DISTANCE TRIANGLE. 8. THE PROJECT DEPENDS ON THE NECESSARY UTILITIES AND RELATED - INFRASTRUCTURE FOR WATER SERVICE BEING FINISHED. IF ANY 6"X3" TEE W/ - - ,�4 _ r ` I I I / \ OFF -SITE WATER FACILITIES REQUIRED TO SERVE THIS PROJECT ARE GATE VALVES \ - _ \ , I SCM A I\ I \\ �I( NOT FINISHED AND ACCEPTED BY THE TOWN WHEN THIS PRELIMINARY _ 3i 1? - / / \ \ \ \ II 1 ( SUBDIVISION PLAN IS APPROVED, THEN THESE FACILITIES MUST BE FINISHED PRIOR TO CONSTRUCTION DRAWING APPROVAL, UNLESS THE \ \ \ \\ i / / // / // / \ 3�0 r 11 - ✓` \ \ I ` 3p> y 2 / \ \ \ \ ��\1 \ ADMINISTRATOR GRANTS AN EXCEPTION. 9. ALL BENDS SHOWN ON PLANS ARE HORIZONTAL BENDS UNLESS OTHERWISE NOTED. PIPES SHALL BE DEFLECTED PER MANUFACTURER'S < / / / 310 370 �k l '� \� \ \ \ \ \ ) II STANDARDS. (I ONP\ � \\ \\ \I \ \ \ I I\ / II I � �I ( / J // I �� / � / /l (\ - �- -- _ \� \ � �. S ��� � \ �11 \ � \ \ \ � \� 1 I I I �✓ / 1 \ \ EASEMENTS: \ 1. WATER, RECLAIM WATER, AND SANITARY SEWER MAINS SHALL BE LOCATED IN A MIN. 20' WIDE PUBLIC UTILITY EASEMENT OR DECICATED 'MINIMUM 2' SEPARATION \ \ )!III // /^ R/W. IN THE CASE OF UTILITIES EXTENDING ADJACENT TO EACH OTHER O \ ( / / / / I I / / / / / / / J I \ _ \ - \ I - / / / 30 \ ` - / % \ \ (I THE EASEMENT MAY BE A VARIABLE WIDTH EASEMENT BUT NO LESS THAN 10' FROM EACH UTILITY LINE. WATER SERVICES UP TO THE METER - - AND FIRE HYDRANT ASSEMBLIES SHALL BE LOCATED IN A 10 WIDE JI / / / I / // / / / / / / �) y\ _ _ - J \ , \ - \ - - \ 1 / / / / I l \ - 7 „ \� \\\\ \ \ \ \ J PUBLIC UTILITY EASEMENT. SEE UTILITY PLANS FOR LOCATIONS OF EASEMENTS. _ 2. ALL PRIVATE STORM DRAINAGE PIPE WITH THE EXCEPTION OF SERVICE l I \ \ / I \ - - - _ _ _ _ - - _ 3 \ \ LINES TO BUILDINGS SHALL BE LOCATED IN A 20' PRIVATE STORM / \ _ I / I J I / - - - ` \ \ I \ C\ ( (/ / ( / - J - _ - - - - _ I �\ \ �� \ \ \ \ \ N X - DRAINAGE EASEMENT. SEE GRADING AND STORM DRAINAGE PLANS FOR ( I 3ti \ L - - - \ \ > \ \ \ J J l \ \ - - \ LOCATION OF EASEMENTS. I / ` _ r \ \ 6" PURPLE. 3. ANY STORM DRAINAGE PIPE EXTENDING FROM A PUBLIC RIGHT-OF-WAY RECLAIMED WATERLINE �/ I) \ \- \ / \- - - - - \ \ INTO THE SITE SHALL BE LOCATED IN A 20' PUBLIC STORM DRAINAGE - - - - - -�--- �� \ \ ) ) I I ` V �� �s --� -�- > > J tl� \ \ I J; J o \ EASEMENT. 10 MIN. MAINTENANCE \ 3 2 &ACCESS EASEMENT �\I0 z \ ^ - \ \ \ / TEMPORARY z \ \ \ I I 1 1 I \ I / ( f - L ^ \ \ I III \ \ \ 1 •• o \ \ - 1�-40'- - �\ \\ Lam\ \\� \ 1 < < I \J // / / 1 I \\ \ \ \- 1 1 h / ) \ \ \ � \ � /J ` \ \ 1 I \ I BLOW -OFF VALVES v RECLAIMED WATERLINE PLAN VIEW SE ARATIO GASLINE J � 317.71 1.50' MIN. -000l SEP RATION / ITA 20+44 90 1 15' RCP ST M A PROPOSED GRADE EXISTING GRADE 0001, 6" GATE VALVE INV: 316. DO STA 10+05.00 SERARATI IN 45° BEN 45' BEN 12" X " TEE + 1.50' M N. 219 6" URPLE „ 22 INV:31 .35 S 1 PARATI WTR N 111 INV: 312.69 11.25° BEN \ \403- 6.SEPA R SIR ATION STA 13+62.2 1.5 ' MIN. i.501 WIS. 18" RC 'SEPARATION SE ARATIO INV: 307.10 15" RCP STRM � P INV: 306.26 411- INV:306. 4 1.50' IN. 5° BEND 1.50' MIN. \-45-13END 36" R P STRM SEPARATION STA 1 +82.57 ^ 6" 6" TEE MIN. INV: 298.73 + 1.50 -SEPARATION \lol 1 STA 14+99 v 8 INCH VC 12" DI R 30" RCP STEM LEGEND DIP INV: 294.87 In 41) PROFILE SCAL M a)[-- M O �� Po M M � O .0) .� NN M M L o M NN M M O � "t 0 NN M M O a M 0 NN M M M a) M 0 co M M N N 00 (�j NN co M (D o NN M M I- M O O o NN M M O io� M ai O �O M M (D ao �M M M O �M M M O �� M r\ �I-- M M (D � co �� M M O ,z cfl �O M M N pp M 'i �� M M (o N (D �ci �Lo M M co Lo� O �r �� M M M "Z M �M M M I- Lo (D ni �M M M Co � O o �N M M (D co 00 O� M M 00 Sri O� M M (o p0 M c N �� M M O O CD a� �� M N I- I- o 0 �� M co Lo L O o eo �� M N (o o coo �� M N (D Z O �� M N O �� co o ao �� M N O � �� M M (o M �� M M M O �� M M 1 M N N �N M M O O '_M M M O M �� M M N O aS '_Lo M M L o N� M M I- ni (o N� M M co �� M M O M M M N NN M M DO O N NN M M N O LQ i N M M 9+80 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 ACCESS ROAD A RECLAIMED WATERLINE PROFILE - STA 9+80 TO 20+75 Horz: 1" = 40' 325 320 315 310 305 300 295 REFER TO GOODWIN PUMP STATION FOR SITE PLAN DEVELOPMENT AND INFORMATION NOTES: 1. PIPE LENGTHS IN PROFILES ARE ACTUAL PIPE LENGTHS FROM CENTER TO CENTER OF STRUCTURE. PIPE LENGTHS IN DRAINAGE DESCRIPTIONS ARE PIPE LENGTHS AS MEASURED IN PLAN VIEW FROM CENTER TO CENTER OF STRUCTURE. 290 KEY C/L EX. GRADE C/L FINAL GRADE 17+00 17+50 18+00 18+50 19+00 19+50 20+00 20+50 LEGEND PHASE I BOUNDARY LINE PHASE II BOUNDARY LINE 000,��aoo��aooaa C � PO eoo •'O�bSI©•'• �o SEAL ; 34 '74 Q ; If 03 2023 �� � •• v l SV ,>` •• ,.(~r Apo 0 U N o� iD 0 1%, E N E W U ; z 0 Lu U .2 N � 6L N � I c-, M (DN Z yJ � � J X < 0 LL 0 0 C)r� T L �OR o � Lrn J W I- U) U) U) U) U) z z z z z W W W W W O 0 0 0 0 0 a U U U U U z z z z z uu W 0 0 0 0 0 p I- I- I- I- I__ lo� lo� lo� lo� lo� W W W W W O a a a a a U) U) U) U) U) U) > z z z z z 0 0 0 0 0 U7 U7 U7 U7 U7 rr) rr) rr) rr) rr) N N N N N 0 0 0 0 0 W N N N N N Q o ,--1 N (r) (r) p (n + -i N + -i o DATE 0511912023 D RAW N BY T. MORRISO/V DESIGNED BY B. MCLAMB CHECKED BY B HALL SCALE AS SHOWN i--i i--i cz I..L Lij z Q z U, ' U w L = O w 00 zwo Cw G J Q Lu J U w' V ol uz 0 0 V 30B NO. 54318 SHEET NO. C4.5B o T C p O E' U � L C O C a- 0 D U O L o� N v z O m m �_0 0 -16 T c o Q> Q U o :3 ocn V c O •� U O U - Q) s Q> 0 0 c rn c � E 0 U• O fn -0 7 � U N C O � U O jN vi 0 0 ) 0 0 C L p 3 �Q) c rn 0 0 a Q� Q> a N T s c 0 L_ / 1\ ~\\\ \\ � \ \ \\\\� \ \ \ \ \ � \ \\\ \---'--•--^ / / — \ J^/ — \ / \ \ I I i Ir / I/' Ir/ L�v� -�--�1--�—/�--�__� \/,-.�� /---/ // /�//J// / � /J ��� �--'rl/-- tj 1 1I — � w r te— / \` \ � \ \\�J �� \�_ \ _,i /� / /^i //---� //' �'/r�i1 //_—__ J,� ,�--/I I / / � / / / / � I \ / �✓—\�'� / ///J� / / Imo/ \ \ \ \ \ �,-- — EXST1� PcM�� _ _ lZ / / _/ _ / SCM A ^ \ \ \ \\\ \ \ \ \ moo£- - - J / EArF BEAR S_TfEA1Vl BUFFER_(,) \\ll I _ 298 _ j �— _-�� �_���- /_ / / / 6" PURPLE PVC j / �JI _( / / // \\� / RECLAIMED WATERLINE - 11.25 ° BEND / .�(.6 MINIMUM 2 SEPARATION � - - -� +50/ 6"X6"TEE W/ 320 - - o...-- - 24 0-_ J �- GATE VALVES IL mAl rJj 311 /, EASEMENTS: 1. WATER, RECLAIM WATER, AND SANITARY SEWER MAINS SHALL BE -- 113 LOCATED IN A MIN. 20' WIDE PUBLIC UTILITY EASEMENT OR DECICATED �r /i / / /� R/W. IN THE CASE OF UTILITIES EXTENDING ADJACENT TO EACH OTHER J� I/( THE EASEMENT MAY BE A VARIABLE WIDTH EASEMENT BUT NO LESS 3�0� \ l \� `I \✓ / -1 / J v / \ - JI I / I \ I ( I I I / \ �� / \ / / / / / /� // / - / / THAN 10' FROM EACH UTILITY LINE. WATER SERVICES UP TO THE METER AND FIRE HYDRANT ASSEMBLIES SHALL BE LOCATED IN A 10' WIDE -312 / \ ( PUBLIC UTILITY EASEMENT. SEE UTILITY PLANS FOR LOCATIONS OF )� EASEMENTS. \ \ \ \ \ I l \ \ \ \ J J / ) \ l l \I _) I - I- \ I _ _ _ / / l J / - r' J L - _ J s 2. ALL PRIVATE STORM DRAINAGE PIPE WITH THE EXCEPTION OF SERVICE JJ/� / \ \ \ \ I \ - _ I \ / LINES TO BUILDINGS SHALL BE LOCATED IN A 20' PRIVATE STORM 6- \ \ \ \ - \ \ - �\ ; / - - / \ I I \ `� `/ ✓ I \ / DRAINAGE EASEMENT. SEE GRADING AND STORM DRAINAGE PLANS FOR \ _ - ' f J / / / I ) / / 1 1 I LOCATION OF EASEMENTS. 3. ANY STORM DRAINAGE PIPE EXTENDING FROM A PUBLIC RIGHT-OF-WAY INTO THE SITE SHALL BE LOCATED IN A 20 PUBLIC STORM DRAINAGE EASEMENT. EXISTING 12" ENTERPRISE GAS LINE \ � -- / / ^ � £8 db'N �j I \'� O r\\—// O / / Jl \ / _ J — / /jJ/ III \ \ 1 \ \ 1 \I \ \ L 1 \ _ \ \ _ ✓ ~' \\ _7 EXISTING ENTERPRISE GAS EASEMENT - SCAL€1"=4Q-�f L I— \ / ^J ( I� 'I 1 I ( I "1�� -�/ /_( -_ - 0 -4 0' - 80' 340 335 330 325 320 315 310 305 C n RECLAIMED WATERLINE PLAN VIEW ING ENTERPRISE GAS EA EMENT - 6" X " TEE 4.5 ' MIN. COVER / .52 01�SEPA ATION 1.50' MI ° . N EXISTING 12" ENTERPRISE GAS LINE VE 6" ATE VA " PURP REGISE 1.50' MIN TA 26+01.32 ARATIO 15" RC IN STRM : 322.97 \_169 - 15" RCP STR INV:324.70 15" RCP S RM I V:327.0 1.5 ' MIN. 8- INGH SSWR INV: 316.72 15" RCP TRM INV: 316.99 O m � N N N M M CO � � N N �� M M m � N N co M O � � I, N N co M I- co M 00 O M N co M M M � O � M M �o M O I� � � N M CO M M CO m � N � co co �� M N O � � � M co M co I- (A � � c) M M �o co I- I� � LO � M M M co M � � O CO CO M �� co LO O C') co M M M M M M � � co co M co co I� LO � I,- c) M M M co O � I,- co co M co co N O � I,- � M CO M co � N � � M co M co M 7 � � � M co co M OA � co co co CO co M O O O co � M CO M M N O � CO CO co CO M 7 M O � M M M M co N O M M 340 335 330 325 320 315 310 305 20+50 21+00 21+50 22+00 22+50 23+00 23+50 24+00 24+50 25+00 25+50 26+00 26+50 ACCESS ROAD A RECLAIMED WATERLINE PROFILE - STA 20+50 TO 26+50 4 0 40 PROFILE SCALE NOTES: 1. PIPE LENGTHS IN PROFILES ARE ACTUAL PIPE LENGTHS FROM CENTER TO CENTER OF STRUCTURE. PIPE LENGTHS IN DRAINAGE DESCRIPTIONS ARE PIPE LENGTHS AS MEASURED IN PLAN VIEW FROM CENTER TO CENTER OF STRUCTURE. KEY C/L EX. GRADE - - - - - - - - - - C/L FINAL GRADE REFER TO GOODWIN PUMP LEGEND STATION FOR SITE PLAN PHASE I BOUNDARY LINE DEVELOPMENT AND INFORMATION PHASE II BOUNDARY LINE UTILITY NOTES: 1. ALL CONSTRUCTION WILL BE TO TOWN OF HOLLY SPRINGS OR NCDOT STANDARDS, SPECIFICATIONS, AND DETAILS. 2. ALL DRIVEWAYS MUST BE INSTALLED TO THE MINIMUM TOWN OF HOLLY SPRINGS OR NCDOT STANDARDS. 3. ALL PROPOSED BUILDINGS, VEHICULAR AREAS, PEDESTRIAN AREAS, SIGNAGE AND LANDSCAPING WILL MEET TOWN ARCHITECTURAL AND SITE DESIGN REQUIREMENTS, AS WELL AS THE DESIGN GUIDELINES THAT ACCOMPANY THE MASTER PLAN. WHERE THESE ARE NOT MET, WAIVERS WILL BE SUBMITTED FOR APPROVAL AT TIME OF THE DEVELOPMENT PLAN. 4. WHERE SIDEWALK IS PROPOSED AT THE BACK OF CURB SIDEWALK SHALL BE A MINIMUM OF 6' WIDE. 5. DOUBLE WHEELCHAIR RAMPS ARE TO BE INSTALLED AT ALL PUBLIC STREET INTERSECTIONS WHERE SIDEWALK IS REQUIRED. WHEN SIDEWALK IS NOT REQUIRED, CURB IS TO BE DEPRESSED AT ALL RAMP LOCATIONS. 6. ALL STREETS SHOWN ON THESE PLANS SHALL HAVE THE FULL WIDTH OF RIGHT-OF-WAY CLEARED AND GRUBBED WITHIN 50' OF ALL STREET INTERSECTIONS. 7. NO SIGHT OBSTRUCTINGS OR PARTIALLY OBSTRUCTING WALL, FENCE, FOLIAGE, BERM, SIGN, PARKED VEHICLE, OR OTHER OBJECTS BETWEEN THE HEIGHTS OF TWO FEET AND EIGHT FEET ABOVE THE CURB LINE ELEVATION (OR THE EDGE OF PAVEMENT IF NO CURB EXISTS) SHALL BE PLACED WITHIN SIGHT DISTANCE TRIANGLE. 8. THE PROJECT DEPENDS ON THE NECESSARY UTILITIES AND RELATED INFRASTRUCTURE FOR WATER SERVICE BEING FINISHED. IF ANY OFF -SITE WATER FACILITIES REQUIRED TO SERVE THIS PROJECT ARE NOT FINISHED AND ACCEPTED BY THE TOWN WHEN THIS PRELIMINARY SUBDIVISION PLAN IS APPROVED, THEN THESE FACILITIES MUST BE FINISHED PRIOR TO CONSTRUCTION DRAWING APPROVAL, UNLESS THE ADMINISTRATOR GRANTS AN EXCEPTION. 9. ALL BENDS SHOWN ON PLANS ARE HORIZONTAL BENDS UNLESS OTHERWISE NOTED. PIPES SHALL BE DEFLECTED PER MANUFACTURER'S STANDARDS. QQ���L1CAPO 0fl�dd000p SEAL o 34 '74 Q ; li o3�2o23 o� � ••�I iV ,s' i� -,�r �o�o 0 U N O � iD p N w U z Q 3 0 Lu U .2 N =M —_j OL 6L N Lu 0 O M co (D w 0� Z yJ ul CT J X < < 0 0 C)rLn L GO O � Ln O'� J W F- 0 c� 0 F_ 0 W w U a z 0 0 U) U) U) U) U) z z z z z W W W W Lu 0 F- 00000 a U U U U U z z z z z w 0 0 0 0 0 C) W W W W W O a a a a a U) U) U) U) U) U) z z z z z w 0 0 0 0 0 U) U) U) U) U) Lu Lu Lu Lu Lu rr) rr) rr) rr) rr) N N N N N LuN 0 0 0 0 0 N N N N Q o ,--i N (n (n �o00rno .1 DATE 0511912023 D RAW N BY T. MORRISO/V DESIGNED BY B. MCLAMB CHECKED BY B HALL SCALE AS SHOWN I..L LL U) z J H� U- 0 z 0 U ° ' U w = L = O w 00 zwo < Lu 0 Lu J U w V z H� 0 0 V 30B NO. 54318 SHEET NO. C4.6B o T C 0 0 E' U L c � 0 c o Dof 0 U O L N v z O M0) o T c o 0 Q U O acn V c o •� U 0 0 U — Q� Q) s Q> o 0 c c � U• O fn � U Q C 0 U O jN vi O C3 ) 0 0 C L p 3 �Q) c C7 O CL Q� 0 0 0- 0 L lLl I % _I Il j l j/ �-- � M / POD L ( ( , / / I \ \ \ I `� �\ \ l \ \ M 1 I I M I \ 13.64AC m y _� I \ �—� \\� \\ \m �_ o z I I I l \i \ I �l \ \ \ I� -� \ \\o z �/ I I / I \ \ ` -7 rI / \I z G) EASEMENTS: 1. WATER, RECLAIM WATER, AND SANITARY SEWER MAINS SHALL BE LOCATED IN A MIN. 20' WIDE PUBLIC UTILITY EASEMENT OR DECICATED R/W. IN THE CASE OF UTILITIES EXTENDING ADJACENT TO EACH OTHER THE EASEMENT MAY BE A VARIABLE WIDTH EASEMENT BUT NO LESS THAN 10' FROM EACH UTILITY LINE. WATER SERVICES UP TO THE METER / AND FIRE HYDRANT ASSEMBLIES SHALL BE LOCATED IN A 10' WIDE PUBLIC UTILITY EASEMENT. SEE UTILITY PLANS FOR LOCATIONS OF EASEMENTS. 2. ALL PRIVATE STORM DRAINAGE PIPE WITH THE EXCEPTION OF SERVICE LINES TO BUILDINGS SHALL BE LOCATED IN A 20' PRIVATE STORM DRAINAGE EASEMENT. SEE GRADING AND STORM DRAINAGE PLANS FOR LOCATION OF EASEMENTS. 3. ANY STORM DRAINAGE PIPE EXTENDING FROM A PUBLIC RIGHT-OF-WAY I INTO THE SITE SHALL BE LOCATED IN A 20' PUBLIC STORM DRAINAGE EASEMENT. z \ \ _/ I �- \ TEMPORARY' 6" x 6" TEE & 3 \ � \ \ \ \ � \ � � 1 \ 1 \ / / / / J / I I / / J / ) I I ( / I r' \ BLOW -OFF VALVE, > GATE VALVES \ \ \ \ \ \ � _ p 24. I 1 \\ L zL \ i\ \ _ \ J 1 + / 6 PURPLE PVC L l) \I> \ — l 7 ✓ �/ 12'� s 1\` 13 RECLAIMED WATERLINE— \\S,4 + 44.+ MINIMUM 2' SEPARATION R 14* / 15+�0 \15+5 1�k9� s R \ +00 '16+ ,' TEMPORARY 12 W / / / / S SAN s BLOW -OFF VALVE -I 1 � \`,J�\ �j r � I 2"W F L `.. Z\ I 1 �,_�1 , \ \ \\\ � \II `\, �\ \\ 11 1 \ �1 I V ✓�� �� ___, �/ �✓ \> Z -7 r� \` �7 I ( r/ 340 335 330 325 320 315 310 305 300 RECLAIMED WATERLINE PLAN VIEW STA " GATE VALV 10+80.85 --� 6' TEMPORARY — 1 S A 10+01. 7 63 5" RCP cTRM ATE VALVE 10+91.32 INV: 327.20 CA Ii " ST SEPARA ION -n 12" DUCTILE IROl WTR RTA + SEPARATION / 161 1 " RCP S 1.50' MIN. SEPA ATIOW RM 159 157 1.50 MIN. .50' MIN. PVC— SEPARATION SE PARATIO PURP E. E� BL W-OFF VALVE 8" DU TILE IRON STA 16 51.41 INV: 316.44 15" IRCP STRIA INV: 316.88 LEGEND ® DIP O Ct M O '6 O Oo M co M M O 00 M M M co 00 I� c0 co M co M O I" O (,) M M M co <r M M M M 00 Lo ('i (,) co M M O N (,) M M co N M M M co M O (,) co co co N O ai (,) N co M L Oo O N N co M co N 00 Oo N N co M co 00 N N N co M O co I� N N co M . cp N N co M O I� . O (.0 N N co M Co L cp O N N(o co M I� co (7 (O O N M M O co M (O cp N N M M � co (O (O N N M M (O co cfl N N M M O L co (O N N M M N I� co cfl N N M M Lo 00 O N N M M O O N N M M O N N N M M N N N M 340 335 co Q SCALE 1 "=40' z 0 40' 80' NOTES: 1. PIPE LENGTHS IN PROFILES ARE ACTUAL PIPE LENGTHS FROM CENTER TO CENTER OF STRUCTURE. PIPE LENGTHS IN DRAINAGE DESCRIPTIONS ARE PIPE LENGTHS AS MEASURED IN PLAN VIEW FROM CENTER TO CENTER OF STRUCTURE. KEY C/L EX. GRADE - - - - - - - - - - C/L FINAL GRADE 330 REFER TO GOODWIN PUMP LEGEND STATION FOR SITE PLAN PHASE I BOUNDARY LINE DEVELOPMENT AND INFORMATION PHASE II BOUNDARY LINE 325 320 315 310 305 300 9+80 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 16+80 4 UTILITY NOTES: 1. ALL CONSTRUCTION WILL BE TO TOWN OF HOLLY SPRINGS OR NCDOT STANDARDS, SPECIFICATIONS, AND DETAILS. 2. ALL DRIVEWAYS MUST BE INSTALLED TO THE MINIMUM TOWN OF HOLLY SPRINGS OR NCDOT STANDARDS. 3. ALL PROPOSED BUILDINGS, VEHICULAR AREAS, PEDESTRIAN AREAS, SIGNAGE AND LANDSCAPING WILL MEET TOWN ARCHITECTURAL AND SITE DESIGN REQUIREMENTS, AS WELL AS THE DESIGN GUIDELINES THAT ACCOMPANY THE MASTER PLAN. WHERE THESE ARE NOT MET, WAIVERS WILL BE SUBMITTED FOR APPROVAL AT TIME OF THE DEVELOPMENT PLAN. 4. WHERE SIDEWALK IS PROPOSED AT THE BACK OF CURB SIDEWALK SHALL BE A MINIMUM OF 6' WIDE. 5. DOUBLE WHEELCHAIR RAMPS ARE TO BE INSTALLED AT ALL PUBLIC STREET INTERSECTIONS WHERE SIDEWALK IS REQUIRED. WHEN SIDEWALK IS NOT REQUIRED, CURB IS TO BE DEPRESSED AT ALL RAMP LOCATIONS. 6. ALL STREETS SHOWN ON THESE PLANS SHALL HAVE THE FULL WIDTH OF RIGHT-OF-WAY CLEARED AND GRUBBED WITHIN 50' OF ALL STREET INTERSECTIONS. 7. NO SIGHT OBSTRUCTINGS OR PARTIALLY OBSTRUCTING WALL, FENCE, FOLIAGE, BERM, SIGN, PARKED VEHICLE, OR OTHER OBJECTS BETWEEN THE HEIGHTS OF TWO FEET AND EIGHT FEET ABOVE THE CURB LINE ELEVATION (OR THE EDGE OF PAVEMENT IF NO CURB EXISTS) SHALL BE PLACED WITHIN SIGHT DISTANCE TRIANGLE. 8. THE PROJECT DEPENDS ON THE NECESSARY UTILITIES AND RELATED INFRASTRUCTURE FOR WATER SERVICE BEING FINISHED. IF ANY OFF -SITE WATER FACILITIES REQUIRED TO SERVE THIS PROJECT ARE NOT FINISHED AND ACCEPTED BY THE TOWN WHEN THIS PRELIMINARY SUBDIVISION PLAN IS APPROVED, THEN THESE FACILITIES MUST BE FINISHED PRIOR TO CONSTRUCTION DRAWING APPROVAL, UNLESS THE ADMINISTRATOR GRANTS AN EXCEPTION. 9. ALL BENDS SHOWN ON PLANS ARE HORIZONTAL BENDS UNLESS OTHERWISE NOTED. PIPES SHALL BE DEFLECTED PER MANUFACTURER'S STANDARDS. 0 40 PROFILE SCALE CAPO •'O�SSI©•'• �o SEAL 34 '74 Q ; If o3 2o23 0 U o � 0 N W U Q 3 0 Lu U a� N Lu� 6L N � o O M ax'-'c� (Dw� Z J U) x 0 0 �Ln L �0� o � LnON J W I- �13 U)U)U)U) U) z z z z z W W W W W O 0 0 0 0 0 a U U U U U uu W 0000 0 o W W W W W O a a a a a z z z z z Lu0 0 0 0 0 Lu Lu Lu Lu Lu rr) rr) rr) rr) rr) N N N N N O O O CD CDLu N N N N N Q O i N (r) (r) 0 (n , -i N , -i O l\O 00 0) C) DATE 0511912023 D RAW N BY T. MORRISO/V DESIGNED BY B. MCLAMB CHECKED BY B HALL SCALE AS SHOWN ■ 9 LL U) zLij H� U- 0 z 0 �--� ol/ U ° I.J^_ ' U w = L = O w 00 zLu Lu 0 � J Q Lu J U w V 30B NO. 54318 SHEET NO. C4.7B `o -0 0 Q>a 00 �V) �z 0 o c � T C 0 0 E' U L c � 0 c 0 � U Oof 0 L N v z 0 M 0) m.s �_0 T c 0 o a U O ocn V c 0 •� U 0 N 01 s Q> 0 0 c c � U• O cn � U Q C 0 U O >N vi 0 O ) 0 0 C L p 3 Q) c 0 0 Q� o 0- 0 L 36' MIN. LOCAL ROADS - SPEED LIMIT 25 MPH St M co iU 00 G M 200 36' MIN. 6' SPEED LIMIT 25-40 MPH �� -r 0o=lName-� G 0 NOTES: 1. 42" MINIMUM BURY DEPTH FOR BREAKAWAY GALVANIZED U-CHANNEL PER NCDOT STANDARDS. 2. ALL POLES SHALL BE BREAKAWAY, SUPPLIERS TO SUBMIT FHWA AND/OR NCDOT APPROVAL LETTER WITH QUOTES REGARDING PROPOSED BREAKAWAY DETAIL. 3. FOR SIGN BLADE INFORMATION SEE DETAIL HS357. 4. ALL SIGNS MUST MEET MUTCD STANDARDS AND GUILDEUNES. 5. ALL MATERIAL TO MEET REQUIRED SPECS. AS ATTACHED. 6. ALL MOUNTING HARDWARE SHALL BE BLACK. Decorative black powder coated alum. pineapple) finial) with Traffic control I I backplate sign size varies_ 3" dia black powder coated alum. post Decorative black powder Town standard street blade mounts coated alum. pineapple finial inside a custom extruded black Imperial post systems D powder coated alum. frame. series Finial #7 or (2 blades per unit) equivalont. Decorative black powder coated alum. pineapple finial Imperial post systems D series Finial #7 or Decorative black powder equivalant. coated alum. pineapple finial Imperial post systems D Town standard street blade mounts Cast iron bracket series Finial #7 or inside a custom extruded black equivolant. powder coated alum. frame. T (2 blades per unit) \ Cast iron w 4 a I aluminum panel L reflective vinyl �hics, mounted to a am backplate using w N iless steel bolts. Mounts :tly to black powder to xI .ed alum. post as shown Iel Size: 30"00") h ck powder coated cplate Size: 32"x32") 3" dia black powder 3" dio black powder coated alum. post coated alum. post Se e Bose Note See Base Note I 48' MIN. I SPEED LIMIT 40 MPH AND ALL MULTI -LANE CROSS SECTIONS0. NOTES: A� 1. ALL CURRENT MUTCD STANDARDS SHALL PREVAIL (2D.43 STREET NAME SIGNS) 2. 36" MIN. LENGTH OF BLADE WILL VARY DEPENDING ON THE NUMBER OF LETTERS IN THE STREET NAME. Private Traffic Control Stop Sign Street Name 3. IN THE CASE OF PRIVATE STREETS, THE HOLLY LEAF LOGO WILL BE REPLACED WITH A SQUARE YELLOW BOX THE Sign Blade Only SAME SIZE AS LARGE CAPS ON SIGN WITH THE WORDS "PRIVATE STREET" IN BLACK. Street *Height varies depending on speed of road. See detail HS357 for blade sizes. 4. BLADE THICKNESS: 2.Omm (36"-47.9"); 3.2mm (>- 48") w/Traffic Control Blade only 5. GREEN RETROREFLECTIVE BACKGROUND WITH WHITE REFLECTIVE LETTERS. - Local Road - 25 mph...........................................................162.. ...................150" 6. THE TOWN LOGO (PICTOGRAPH) SHALL ALWAYS BE TO THE LEFT OF THE STREET NAME. - Speed Limit - 25-40 mph .................................................... 170 .. ................... 158" See Base Note o+ .063 aluminum panel s with reflective vinyl a graphics, mounted to a, °i custom backplate. Mounts directly to black powder in coated alum. post as shown a, (Panel Size: 30"x30") a, rn (Black powder coated Backplate Size: 32"x32") 3" dia black powder coated olum. post \ R/W i MINIMUM PAVEMENT DESIGN 2' 1 5.0' 1 5.0' 1251 1-1/2" S9.5B SIDEWALK 2-1/2" 119.0 Base Note: 8" A.B.C. Black powder tooted " ' base Imperial Post NOTES: \ /� Systems D Series \ Base #8 or equivalont 1. NORMAL CROWN OF 1/4" PER FOOT UNLESS OTHERWISE DIRECTED BY THE UTILITY STRIP DIRECTOR OF ENGINEERING. STREET TREES WITH 2. PAVEMENT DESIGN SHALL BE AS SHOWN, ROOT GUARDS PER OR AS CALCULATED, WHICHEVER IS GREATER. HS816 Stop Sign With Blades 3. ALL COLLECTORS SHALL BE NO LOAD. 4. PAVEMENT DESIGN WILL REQUIRE NCDOT APPROVAL. R/W 59.0' RIGHT OF WAY 1251 5.0' 1 5.0' 1 2' ROADWAY ROADWAY SIDEWALK I \ UTILITY STRIP STREET TREES WITH ROOT GUARDS PER SEE DETAILS 311/312/314 HS816 7. FONT SHALL BE: ARTISTIC SERIES B2000 DRAWING NOT TO SCALE - Speed Limit - 40+mph (or multi -lanes cross-section).....182.. ...................182" DRAWING NOT TO SCALE POST -MOUNTED STANDARD TOWN STREET NAME SIGN BLADE STANDARD DETA/L NUMBER: HS357 *"Holly UPGRADED TRAFFIC CONTROL AND STREET NAME SIGN AND POSTS STANDARD DETAIL NUMBER: HS361 _ Holly 2 LANE NON RESIDENTIAL COLLECTOR 36 BTB ON 59' R/W DA TE REVISIONS (�Springs DA TE REVISIONS Springs TOWN OF HOLLY SPRINGS ENGINEERING DEPARTMENT 4 ' Dise°verThe9aaree. TOWN OF HOLL Y SPRINGS ENGINEERING DEPARTMENT ' 9 20 D,Sc°verTheS°aree. TOWN OF ROLL Y SPRINGS ENGINEERING DEPARTMENT GENERAL NOTES: 1. THIS PROJECT IS IN THE TRIASSIC BASIN. ALL PUBLIC ROADWAYS WILL BE REQUIRED TO MEET ALL SPECIAL DESIGN REQUIREMENTS AS OUTLINED IN THE ENGINEERING DESIGN AND CONSTRUCTION STANDARDS SECTION 3.02J. 2. THE PAVEMENT DESIGN WILL REQUIRE NCDOT APPROVAL. THE MOST RESTRICTIVE CROSS-SECTION BETWEEN THE MINIMUM DESIGN, CALCULATED PAVEMENT DESIGN, TRIASSIC DESIGN, AND NCDOT DESIGN WILL APPLY. 3. 2-LANE NON-RESIDENTIAL COLLECTOR AND 4-LANE THOROUGHFARE ROADWAY CROSS SECTIONS COMPLY WITH TOHS UPDATED CTP LC-2A AND T-4A MINIMUM STANDARDS, RESPECTIVELY. CONNECT TO FUTURE CONNECT TO FUTURE POTENTIAL SPACE POTENTIAL SPACE PEDESTRIAN PATHWAY / \ 5' WIDE HARD SURFACE PATHWAY/TRAIL - OPEN SPACE DECORATIVE CROSSWALK CONNECT TO FUTURE POTENTIAL SPACE 5' SIDEWALK PEDESTRIAN PATHWAY CONNECTING TO OPEN SPACES NOT TO SCALE H S 357 STANDARD LEAF WIDTH PER MANUFACTURER -MAX 8' � RAIL �� RAIL 1"0 o x16GA. C9 PICKET �r 3" x1 ?GA. LLI POST 10" [IfT FINISHED GRADE 2" 4", TYPICAL 2'-0" l l �U. U. 4" 4" 12" 3000 PSI 12w �3000 PSI CONC. FOOTING CONC. FOOTING (TYP.) (TYP.) NOTES: 1. FENCE SHALL BE ALUMINUM POWER COATED WITH BLACK PAINT. 2. DIMENSIONS MAY VARY. MAX HEIGHT IS 60". DECORATIVE FENCE MP-$ 0 SCALE: NTS 96' 28'R (TYP) 26' 96' DIAMETER CUL-DE-SAC 28'R (TYP) REQUIREMENTS FOR DEAD-END FIRE APPARATUS ACCESS ROADS LENGTH (feet) WIDTH (feet) TURNAROUNDS REQUIRED 0-150 20 None required 120-foot Hammerhead, 60-foot 'Y" or 151-500 20 96-foot diameter cul-de-sac in accor- dance with Figure 0103.1 120-foot Hammerhead, 60-foot 'Y" or 501-750 26 96-foot diameter cul-de-sac in accor- dance with Figure D103.1 60-FOOT "Y" r 60'-{-60'�{ 120' HAMMERHEAD (TYP) 21, 26' 20' MINIMUM CLEARANCE AROUND FIRE HYDRANT 28'R (TYP) 20']- ACCEPTABLE ALTERNATIVE TO 120' HAMMERHEAD HS 361 UPGRADED TRAFFIC CONTROL SIGN DETAIL 106' RIGHT OF WAY 78' S UTILITY ROADWAY SECTION S UTILITY STRIP 24' 20' 24' STRIP EX POWER ROADWAY MEDIAN ROADWAY 10' MULTI - EASEMENT PURPOSE PATH Z' j OFFSET i I ��SEE DETAIL SEE DETAIL- J- � 311/312/314 311/312/314 UTILITY STRIP 2.5' 1.5' 1.5' (STREET TREES WITH 2.5' ROOT GUARDS PER DETAIL MINIMUM HS816) PAVEMENT DESIGN 3EXISTING " S9.5C 4" 110.00 DUKE ENERGY POWER EASEMENT 10" C.A.B.C. NOTES: 1. NORMAL CROWN OF 4" PER FOOT UNLESS OTHERWISE DIRECTED BY THE DIRECTOR OF ENGINEERING 2. PAVEMENT DESIGN SHALL BE AS SHOWN, OR AS *MODIFIED HS307B HOLLY SPRING 4 LANE WITH MEDIAN DETAIL TO CALCULATED, WHICHEVER IS GREATER. COMPLY WITH NCDOT AND HOLLY SPRINGS STANDARD. 3. PAVEMENT DESIGN WILL REQUIRE NCDOT APPROVAL. WOODS CREEK ROAD IMPROVEMENT CROSS SECTION 4 LANE -MEDIAN THOROUGHFARE 79' BB ON 103' ROW NOT TO SCALE Dead-end fire apparatus access roads in excess of 150 feet (45 720 mm) in length shall be provided with an a Droved area for turn in around. f're apparatus. See table above. DRAWING NOT TO SCALE OverP750 fors ap�roval requ re� Grass pavers are acceptable alternatives to concrete, asphalt or gravel for the 120' Hammerhead or the acceptable alternative to 120' Hammerhead. Specification and data sheets on the pavers to be used will need to be submitted for approval. DEAD END ROAD DETAIL STANDARD DETA/L NUMBER.• HS367 VH0r'y DA TE REVISIONS Spings TOWN OF HOLLYSPRINGS ENGINEERING DEPARTMENT 9 9 2ODiscover The Source. c7-AA1nAPn 9'_ R" %URB & H.O.U. NOTES: 1. STONE IS REQUIRED UNDER ALL TYPES OF CURB AND GUTTER ON STREETS 2. STONE IS NOT REQUIRED ON PARKING LOTS A.B.C. UNDER CURB AND GUTTER TOWN OF HOLLY SPRINGS ENGINEERING DEPA R TMEN T 7" 3 112" MIN. DRAWING NOT TO SCALE STANDARD DETAIL NUMBER: FW22 DA TE REVISIONS DRAWING NOT TO SCALE STANDARD DETAIL NUMBER: HS305A DA TE REVISIONS HOLLY fz4fe SPRINGS Disce the S, GENERAL NOTES: 1. THIS SUBDIVISION IS IN THE TRIASSIC BASIN. ALL ROADWAYS WILL BE REQUIRED TO MEET ALL SPECIAL DESIGN REQUIREMENTS AS OUTLINED IN THE ENGINEERING DESIGN AND CONSTRUCTION STANDARDS SECTION 3.02J. 2. THE PAVEMENT DESIGN WILL REQUIRE NCDOT APPROVAL. THE MOST RESTRICTIVE CROSS-SECTION BETWEEN THE MINIMUM DESIGN, CALCULATED PAVEMENT DESIGN, TRIASSIC DESIGN, AND NCDOT DESIGN WILL APPLY. �6 72" 6" Holly ) Springs �� Discover The Source. 6' WIDE IMPRINTED AGGREGATE REINFORCED PREFORMED THERMOPLASTIC PAVEMENT MARKING SYSTEM MANUFACTURER-BELGARD COLOR - HOLLAND STONE PATTERN - HERRINGBONE V VVIL./L VVI II I L I I ILf\IVIvr Lnv I Iv v I r\IrL DECORATIVE IDENTIFIABLE PEDESTRIAN CROSSWALK TREATMENT NOT TO SCALE 3.0INCHES NCDOTS9.5C 4.0 INCHES NCDOT 119.00 10.0INCHES NCDOT CRUSHED *MIRAFI HP270 AGGREGATE BASE COURSE OR GEO-FABRIC (OR IC:D �00�00�00�oO�CO 5.0 INCHES B25.0 EQUIVALENT) PLACED ON COMPACTED SOIL SUBGRADE `SUBGRADE COMPACTED TO 95% STANDARD PROCTOR (REFER TO PROJECT SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS) DENOTES HEAVY DUTY ASPHALT PAVEMENT ON PLANS 4-LANE THOROUGH (HEAVY DUTY ASPHALT) NO SCALE 1.5 INCHES NCDOT S9.5C 2.5 INCHES NCDOT 119.00 0 0 0 0 0 0 0 *MIRAFI HP270 � AGGREGATE T BASE CRUSHED ED GEO-FABRIC (OR AGGREGATE BASE COURSE EQUIVALENT) PLACED ON COMPACTED SOIL SUBGRADE SUBGRADE COMPACTED TO 95% STANDARD PROCTOR IN ACCORDANCE WITH EDCS 3.02J (REFER TO PROJECT SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS) DENOTES HEAVY DUTY ASPHALT PAVEMENT ON PRIVATE ROADS IN PLANS NON-RESIDENTAIL COLLECTOR (HEAVY DUTY ASPHALT) NO SCALE QO��p60(Ifti1�00p0 klvL C ARO °oo o° $ �..(�•C•v•. �f °o q 'EA�t 77 L O 34P74 QII o3 2023 o� •��IN . �Qoo 0 U n 0 V7 O r� N E Lu U = 2!!}: F- 3 a 3 U) U) U) U) U) LULU (W,� N Z Z Z Z Z c w w w w w w _,1 00 LU 0 CD 0 a= o 0 0 0 0 0 U U U U U z LU Z3 M 11� J X U >z> >z> >z >z> >Z <�-6< w 00000000 00 0 -i Z T Ln o a a a a a .L U7 U7 U7 U7 U7 U7 `` z z z z z o°? w 0000 0 .--I C� U7 U7 U7 U7 U7 U-) rn11 U7 O (D O o w w_ 2 w Q fr) N 0 O fr) N 0 (V ,\-I fr) N 0 (V r1j fr) N 0 (V (r) fr) N CD (V (VI-_ ( r) U 0 r) ,--I N ,--I o 0 0 DATE 0511912023 O DRAWN BY T" 1VORRISO/V } • DESIGNED BY • B. MCLAMB CHECKED BY B HALL SCALE 0 L7 V�J H� o� 0 Q �cn 0X J O �X ° Q J U 0 � o o � O W o i z ° 06 0 0 0 z U) 0 O� 1�1 0 O I..LI a zU LU o 0 ,1 O ° Q Z�\ nC: z (D Uj o-0 Q � > 0 >o z o X� 1) ° ,- a o O� z o 0cn o .> o cn o V o � o > N N V) o a JOB NO. o 54318 V '0'�� C1 Q SHEET NO. C7.0 V, �>, L WITH THE EXCEPTION OF THE BASE SECTION, ALL 48" OR 60" DIAMETER OTHER COMPONENTS OF THE MANHOLE SHALL BE IN ACCORDANCE WITH STD. DETAIL HS706 4g" OR 60" DIAMETER FLEXIBLE RUBBER BOOT IN CONFORMANCE WITH ASTM C-923 8 e d RISER UNIT a e DOGHOUSE BASE 11 , A DOGHOUSE SEAL ANNULUS AROUND BASE PIPE WITH BRICK AND SEAL AROUND EXISTING PIPE MORTAR WITH NON -SHRINK GROUT ° a a RUBBER BOOT PROPOSED PIPE 4"x8"x16" SOLID CONCRETE BLOCK a aG�P STACKED TWO HIGH (TWO SETS g�� EACH SIDE OF EXISTING MAIN) ° POUR 8" BASE �- MINIMUM 12" TO FORM OR TO UNDISTURBED AREA _ WIRE MESH MIN. 12" FORMED INVERT TO ALLOW FLOW TO EXISTING PIPE. MAY BE POURED AT SAME TIME AS BASE #57 STONE COMPACTED CONCRETE BLOCK CUT AND REMOVE TOP HALF OF PIPE 6x6-W8xW8 WOVEN WIRE MESH AFTER APPROVED TESTING OR TOHS BASE UNIT INSTALLMENT INSPECTOR APPROVES INVERT INSTALLMENT NOTES: 1. DOGHOUSE OPENINGS IN PRECAST UNITS SHALL HAVE A RADIUS OF 4 TO 8 INCHES LARGER THAN THE EXISTING PIPE DIAMETER. 2. CAST -IN -PLACE CONCRETE SHALL BE 4000 PSI, PER ASTM C-94. 3. ALL PRECAST MANHOLE COMPONENTS SHALL MEET ASTM C-478. 4. BENCH SHALL SLOPE UPWARD FROM THE SPRINGLINE TO THE PROJECTED LEVEL OF THE PIPE CROWN OR 8 INCHES ABOVE THE SPRINGLINE, WHICHEVER IS LESS. DRAWING NOT TO SCALE STANDARD DETAIL NUMBER: H8728 STANDARD PRECAST CONCRETE DOGHOUSE MANHOLE Holly DA TE REVISIONS � � � Springs TOWN OF HOLLY SPRINGS ENGINEERING DEPA R TMEN T Discover The Source, STANDARD MANHOLE R' 1 RING AND COVER _ _ _ MAX 20" } 12" MAX i a. MANHOLE BREAK POINT 1 2 -O" <... I e} USE FOUR 3/8 INCH ANCHOR a: < e BOL IS TO BOLT FRAME s °. ECCENTRIC TAPER a p TO SPACER. USE ROPE ;: UNIT MAS77C SEAL BETWEEN FRAME AND SPACER. - - - - - - - SEE STANDARD DETAIL FOR MANHOLE. STEPS MAY NOT BE LOCATED ABOVE THE INFLUENT OR EFFLUENT PIPE - - - - - - - 4' DIA OR 5' DlA ALL LIFT HOLES WHICH COMPLETELY PENETRATE O-RING JOINT THE MANHOLE SHALL BE FILLED WITH NON - OR BUTYL RUBBER JOINT SHRINKING GROUT. 1 =4" TYR a .a ° RISER ° d UNIT ° 8" WIDTH MAS77C ASPHALT WRAP TO BE 5" � APPLIED TO ALL JOINTS BASE UNIT SOLID CONCRETE BLOCK/BRICK & MORTAR INVERT OR PRECAST INVERT MEE77NG�. ,,ko - SPECIFICA 17ONS a PIPE 6" NOTES 6" BEDDING 1. ANY MANHOLE OVER 20' IN DEPTH SHALL BE 5' IN DIAMETER. 2. NO FLAT TOPS ALLOWED. DRAWING NOT TO SCALE STANDARD PRECAST CONCRETE MANHOLE STANDARD DETAIL NUMBER: Hs7os �,�Holly DA TE REVISIONS , - 1 Springs e Discover The Source. TOWN OF HOLLY SPRINGS ENGINEERING DEPA R TMEN T STANDARD M.H. RING AND COVER LABELED APPROPRIATELY S7EPS AT 16" ON CENTER (ONLY INSTALLED WHEN \ DEPTH EXCEEDS 3) K T l " x 4' x 0'-8" LG. w/ 2- 0 HOLES (2 REQ'D) BRASS 1-2 x 2 x # (LENGTH DEPENDENT ON MANHOLE DIAMETER & SIZE OF VALVE) A w/ J70 x I" LG. SLOTTED FINISHED GRADE HOLE (VAR/ES) BRASS L2 x 2 x # (LENGTH DEPENDENT ON SIZE OF VALVE) w/ 4- 90 HOLES 4 < }0 CONC. EXP. i `a 4' PRECAST ANCHORS (2 EA. PLATE) CONC. MANHOLE NOTE �. 2" BRASS AIR/VACUUM VALVE SUPPORT ANGLES TO BE POS177ONED OPPOSITE 24' MIN `° MANHOLE OPENING. 4" THK. X 1j" WIDE BRASS FLAT BAR (LENGTH ` AS DETERMINED BY VALVE BODY DIAMETER) PLAN R" x 4" x 0'-8" LG. w/ 2- J"0 HOLES (2 REQ'D) J70 CONC. EXP. ANCHORS (2 EA PLATE) • '� BRASS 1-2 x 2 x i (LENGTH 0 12 2" FLOOR DRAIN TYPICAL SECTION 4" THK. X 1}" WIDE BRASS FLAT BAR (LENGTH AS DETERMINED BY VALVE BODY DIAMETER) .1-AIR/VACUUM VALVE BRASS TAPPING SADDLE MANHOLE OPENING ABOVE BRASS0 BOLT, NUT, & WASHER (4 REQ'D) DIP MAIN (WATER) OR C900 PVC (RECLAIMED) DEPENDENT ON MANHOLE DIAMETER & NOTES: SIZE OF VALVE) w/ 10 x 1" LG. SLOTTED HOLE 1. TAP SIZE AND ISOLATION VALVE TO BE SAME SIZE AS 2" THO. BRASS BALL VALVE AIR VALVE. 2. ALL PIPING AND FITTINGS, IN THE MANHOLE, SHALL BE 2" BRASS NIPPLE (TYP.) BRASS OR BRONZE UNLESS NOTED. DIP MAIN (WATER) OR C900 PVC (RECLAIMED) 3. MANHOLE STEPS SHALL BE PLACED 16" O.C. BRASS TAPPING SADDLE 4. CONCENTRIC CONES MAY BE USED FOR AIR VALVE MANHOLES LESS THAN 5' IN DEPTH. 12" No. 57 STONE TYPICAL CONCRETE F0077NG (3000 PSI. CONCRETE) VAL VE BOX AND COVER THREADED COUPLING 6" BELOW LID CONCRETE DRAWING NOT TO SCALE STANDARD DE -TAIL NUMBER: HS605 Holly TEMPORARY BLOW -OFF ASSEMBLY DA TE REVISIONS i Springs TOWN OF HOLLY SPRINGS ENGINEERING DEPARTMENT 6 27 z3 FULL SIZE GA IF VAL IERESTRICTIONNOlEADDED �� Discover The Source. MIN. 1/2" x 1 1/2" LAG BOLTS W/ LEAD SHIELD ANCHORS CONCRETE ENCASEMENT (POSITION AS SHOWN) (3000 PSI "I Y) (4 REQUIRED) CONCRETE ENCASEMENT d d FINISHED (3000 PSI MlX) ¢ � GRADE �.Q I ``��� 1/2" MIN. ASPHALT d BASE COURSE - - I u O O 18" MIN. I I COMPACTED BACKFILL d A STD MANHOLE RING AND COVER PLAN +-S7D MANHOLE SECTION FINISHED - 12" MIN GRADE d d. n BASE - COURSE COMPACTED BACKFILL NOTES: 1. ALL MANHOLE COVERS TO HAVE 2 HOLES ONLY. 2. USE SOLID LID ON ALL MANHOLES LOCATED IN LOW AREAS OF ROAD PROFILE. 3. MANHOLE RING TO BE BOLTED AS SHOWN W/ROPE MASTIC SEAL BETWEEN FRAME AND SPACER. 4. DOMESTIC MADE IN USA AND MEET H2O LOADING NCDOT NO 840.54. DRAWING NOT TO SCALE STANDARD MANHOLE RING AND COVER ENCASEMENT STANDARD DETAIL NUMBER: H8710 Holly FOR MANHOLES LOCATED IN PAVED AREAS DA TE REVISIONS Springs TOWN OF HOLLY SPRINGS ENGINEERING DEPA R TMEN T 7124109 U� Discover The Source. I II I II I II I� II I� II I� II a IQ II CO h Im II I 5' �00" I II I� II IN I I I� II o IW II K5 PLAN VIEW NOTES: 1. SIDEPATH SHALL BE 6" DEPTH AT ALL DRIVEWAYS. 2. SIDEPATH SHALL BE 6" DEPTH AT ALL HANDICAP RAMPS. 3. TRANSVERSE EXPANSION JOINT TO BE A MAX OF 50 FEET. * VARIES - SEE APPROVED PROJECT PLANS EXIS77NG 2 =6" CURB AND GUTTER GRASS UTILITY S7RIP PROPOSED SIDEPA 7H 1/2" / ft 1/4" / ft. (GONG. 3000 PSI) COMPACTED SOIL TO A DENSITY VARIES OF NO LESS THAN 957 TYPICAL SECTION SIDEPATH SURFACE 4.. 1/4„ 1/8" RAD. 112 \ JOINT FILLER TRANSVERSE EXPANSION JOINT 1' RAISED LETTERING WATER 7/16' VALVE BOX COVER 0 7-5/l6' 2' 6' 1-3/ 1/2' 1-1/2' 0 4-3/8' (PAVED AREAS) Tm.. nNISH£D GRADE 8-9/16' 12 THICKNESS 1-2, 7YP. nN/SHED GRAD£ /N UNPAVED AREAS /N PAVED AREAS 7-9/16' H OR HB BITUMINOUS 7-1/2" MIN. CONCRETE 6-5/16' -- - ---� XD/A. 1-1 2" ...... ... I ... III=III=III-I I 2-1/16' d d ............ '.'��'.'..'.'.'...'.'. (UNPAVED AREAS) .. BASE COURSE CONCRETE 16' ° d ... .... ........ ':'.'.'.'.'.'. .. ENCASEMENT 13-11/16' ° d° (PAVED AREAS) < 12" THICKNESS CONCRETE..... AT 3000 P.S./. 41 OR /-2, H OR HS B/fUMINOUS.' d CONCRETE ° CONCRETE ... .. .. ........ VALVE BOX a ,a ENCASEMENT t AT 3000 P.S/. ° VAL VE BOX .. ... .. ........ .. .. .. .. .. .. ... ..6-1/16' COVER TAMPED BACKFILL .... .................. ...... ...'..... NOTE TO CON.17rACAV.<' ' ' ' ' '=' ..... ..'.' TAMPED BACKRLL / ° ° VALVE BOX, SHOULD- NO T'.'.'.'.'.'.'.'.'.... ............... _ . L 711 CONTACT MATN'OR.'VALVE.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.................'.'.'. . ................. _ IrwilPLAN MAIN VALVE NOTES: 1. D.I.P. SHALL BE USED FOR VALVE BOX EXTENSIONS. TAMPED eACKr7LL 2. VALVE OPERATING NUT MUST BE EXTENDED SO .... . .. . . .. . . .. . ............. THAT THE DEPTH IS NO GREATER THAN 5' FROM ............... ..... THE SURFACE USING A MANUFACTURER APPROVED EXTENSION KIT. BLOCK DOT RATED SOLID 3000 PSI 3. PRECAST CONCRETE ENCASEMENT IS ALLOWED SECTION OUTSIDE OF PAVED AREAS. 4. DOMESTIC MADE IN USA. DRAWING NOT TO SCALE STANDARD VALVE BOX INSTALLATION STANDARD DETAIL NUMBER: HSsrn 'Holly DA TE REVISIONS � Springs TOWN OF HOLL Y SPRINGS ENGINEERING DEPA R TMEN T Discover The Source, 5-0" MAX. 50 -0" SINGLE VAL VE MAX. (IF EXCEEDS MAX D/STANCE NEED ADD/770NAL VAL VE 5' MAX FROM HYDRANT) _ 5 -O" MIN. 5" Stortz connection installed by the manufacturer and part of the hydrant assembly. (No adapters allowed). \ Q 5N NO1ES. HYDRANT TO BE PLACED WITH PUMPER NOZZLE FACING THE CLOSEST CURB. :......: ..... = W MINIMUM OF 8 C.F. =I I °' 3/4" BRIDLE ROD & ROD COLLAR III k NO. 57 STONE ♦=I I I I I MAIN MECYANICAL JOINT •'.•'? ..:.....�,.:'. III 2=0". 6" GATE VALVE MAX. CONCRETE BLOCKING MAIN LINE DUC77LE IRON PIPE MIN. 1/3 C. Y. AT TEE NOTES: 3000 P. S. 1. 1. TOP OF BLOCKING TO BE 2" FROM CONCRETE THRUST BLOCK HYDRANT WEEP HOLES. 1/3 C.Y. AT 3000 PS/ 2. HYDRANTS SHALL BE YELLOW IN COLOR (SHERWIN WILLIAMS PRO INDUSTRIAL URETHANE ALKYD ENAMEL SAFETY YELLOW B54 Y157) DRAWING NOT TO SCALE STANDARD HYDRANT INSTALLATION STANDARD DE -TAIL NUMBER. HS622Holly DA TE REVISIONS OU,_ Springs 11 21 �� Discover The Source STANDARD MANHOLE RING AND COVER d \ a dt F STANDARD PRECAST MANHOLE CAST OR DUCTILE IRON A PIPE CROSS WITH DIAGONAL CUT-OUT (MIN) FOR EASY CLEAN OUT ACCESS 5' 0" DIA. CLASS AWWA-C110 d4. J �✓ I I (MIN) 2 -0 II GROUT STAINLESS BOL T.4' ° STRAPS a a DUC77LE IRON PIPE <. CLASS AWWA-C151 a. CAST OR DUCTILE IRON 90' BEND .......... .... .......... d d < 3" FORMED WITH PRECAST INVERT 4" CONCRETE BLOCK OR CONSTRUCT INVERT WITH CONCRETE GROUT. NOTES: 1. PIPE SIZE FOR DROP TO EQUAL TO INFLOW SEWER PIPE SIZE. 2. MECH. JOINT OR PUSH- ON FITTINGS, ALL BELL, TO BE USED. 3. CORE OR DRILL ALL HOLES FOR PIPE AND BOLTS. 4. DROP MANHOLE MANDATORY WHEN DIFFERENTIAL BETWEEN INVERTS IS GREATER THAN 12". 5. STAINLESS STEEL STRAPS SHALL BE USED ON ALL DROPS GREATER THAN 5 FEET AT 18 INCH INTERVALS. Qo���60flO��OOaO oo° kV V C ARO °000 q�� c 77 � 7 q 'EA)_! 40 O a 34�74 a Q fl 0-- 2023 U U O � O N E LLA U z 4- ~ z 3 a 3 0 LLI U or N < LL _00 (I.LL N r4 LU 0 On) _ 00 J U) x � cz fa LL 0 � -i I T Ln M _ �`1_ L �"D o rn In rn J w U) U) U) U) U) z z z z z w w w w w O 2: 2: 2: 2: 2: 0 0 0 0 0 a U U U U U z z z z z U w 0 0 0 0 0 0 z w w w w w O a a a a a U) U) U) U) U) U) z z z z z w 0 0 0 0 0 U) U) U) U) U) > > > > > rr) rr) rr) rr) rr) N N N N N w 0 0 0 0 O (V (V (V (V (V p c+'1 1 N 1 o O O O _q _q DATE 0511912023 D RAW N BY T. MORRISO/V DESIGNED BY B. MCLAMB CHECKED BY B HALL SCALE AS SHOWN a 0 E 0 O 0 a-o O O 0 z o O Cn o z O o z o Q� 0 Q � N 0 0 0 0 X� E C) o V, COMBINATION AIR VALVE MANHOLE FOR RECLAIM AND WATER MAINS TO WN OF HOL L Y SPRINGS ENGINEERING DEPA R TMEN T L DRAWING NOT TO SCALE STANDARD DETAIL NUMBER.•HS1101 & HS610 `Holly DA TE REVISIONS Springs 1 422 1 Discover The Source. CONCRETE SIDEPATH TO WN OF HOL L Y SPRINGS ENGINEERING DEPA R TMEN T DRAWING NOT TO SCALE STANDARD DETAIL NUMBER: HS380 Holly DA TE REVISIONS Springs 3121 Discover The So STANDARD INSIDE DROP MANHOLE TO WN OF HOL L Y SPRINGS ENGINEERING DEPA R TMEN T DRAWING NOT TO SCALE STANDARD DETAIL NUMBER. H8707 Holly DA TE REVISIONS (�„ Springs 516115 �� Discover The Source. JOB NO. 54318 SHEET NO. C7.1 VARIABLE ^r ROADWAY WIDTH ROADWAY CROSS PIPE TYPICAL SECTION VARIABLE SLOPE 3" _ VARIABLE gL0_P 4 E' 4 6" MAX. 1� --------- 3r1 r-- ------ -- �1 6" MAX. f,' JOINT %' �D B A A B jlD�� FILLER 1 1 L_ __ li ♦1--- ----- r� L Tb _I Te PIPE 3" PIPE T3 Tb L e GROOVE INSTALLATION TONGUE INSTALLATION W D ' .. r , T Te I L PIPE „ L S L PLAN VIEW SIDE VIEW 6 rr �.W-I END VIEW END TREATMENT DIMENSIONS D L W Ts Tb Te A B 1811 W-O" 23" 4" 4" 6" 211/4" 25" 24" 8'-2" 30" 411 411 6" 27%8" 32" 30" 10'-4" 37rr 4" 4" 6r1 335/8" 39" ISOMETRIC VIEW NOTES: 1. CONSTRUCT PIPE END SECTION USING #4 REBAR SPACED 9" EACH WAY AND MEET ALL REQUIREMENTS OF STD. SPEC. 310. 2. CHAMFER ALL EXPOSED CORNERS 3/4" EMERGENCY SPILLWAY CONSTRUCTED OVER UNDISTURBED GROUND AND ARMORED DIMENSIONS ELEV. WITH RIP RAP - -� EMERGENCY SPILLWAY TOP OF DAM WIDTH (� I SEDIMENT TRAP ANTI -SEEP COLLAR RIP RAP DISSIPATER PAD DISSIPATER PAD ANTI -FLOATATION DEVICE \ '. RIP RAP TOP OF RISER \ OUTLET PIPE INVERT IN \ :•- 'r= ' '• OUTLET PIPE INVERT OUT SEDIMENT STORAGE AREA J OUTLET PIPE EARTH DAM CMP/ or RCP RISER PLAN VIEW PAINTED RED CLEANOUT MARK LOCATED HALFWAY UP RISER PIPE WATER LEVEL DURING STORM SKIMMER-,,, SEDIMENT STORAGE .,.AREA GRAVEL FILTER- -I I � i I=IF l=l -I � c STONE PAD-- -11 I'' II'"I I DESIGN ENGINEER MUST SIGN (3'X3'X1'D) AND SEAL BASIN DESIGN BELOW GATE VALVE OR ORIFICE ANTI -FLOATATION DEVICE TRASH RACK 1'-0" MINIMUM FREEBOARD TOP OF DAM EMERGENCY SPILLWAY ELEVATION -1- MINIMUM SLOPES 2-1/2 1 EARTH DAM 1I- ANTI -SEEP COLLAR CMP/ or RCP OUTLET PIPE CROSS SECTION STANDARD RISER -BARREL SEDIMENT BASIN (WITH SKIMMER) TOWN OF HOLLY SPRINGS ENGINEERING DEPAR TMEN T STEEP CUT OR FILL S UPSLOPE TOE SIDE SLOPES 2 1 (MAX.) DISSIPATER PAD RIP RAP Z O U Qa <�CD LL _J O O U 2 2 Z wQQILL 2 Q U 2 O CD I- 2 z w CnI-LLOJ o�cna Z Cr , ? H ao w w a_ H O CM °CZo LL z ~ 00 W r oaC N O p LL Z Q W o H W a I- H U) a w N � O U z c V O F- ro Q U w cc a SHEET 1 OF 1 310.03 LENGTHS OF WIRE NOTES: 1. TEMPORARY SILT DITCH TO BE USED WHERE TOE OF FILL SLOPES EXCEEDS 3 FEET IN VERTICAL HEIGHT AND ALONG STREAMS TO INTERCEPT FLOW AND/OR DIVERT TO A CONTROLLED OUTLET. 2. SILT SHALL BE REMOVED WHEN SILT DITCH IS ONE-HALF FULL. 3. DITCH SHALL BE RECONSTRUCTED WHEN DAMAGED BY EQUIPMENT OR COVERED BY FILL. I _ WASTE MATERIAL -COMPACT, VAR. SEED & MULCH AFTER -I Oa,~`r 2' - 10' CONSTRUCTION OF DITCH 2 VAR.01 �pf I I III -I I IM x 2 �111-III- I 18 CROSS SECTIONAL VIEW TEMP ORA R Y SIL T DITCH TO WN OF HOL L Y SPRINGS ENGINEERING DEPA R TMEN T BOTTOM ANCHORI NCHORED ON BOTH ENDS BAFFLE INSTALLATION - STEP 1 NOTES: 1. DRIVE STEEL FENCE POST AT LEAST 18" INTO SOLID GROUND. 2. WOOD POSTS ARE NOT ACCEPTABLE. 3. USE STAPLES 1' APART TO ATTACH FABRIC. 4. 4' MAX BETWEEN POSTS. 5. CLEAN OUT WHEN 1/2 FULL. 6. 700-900 GRAMS PER SO. METER COIR FABRIC. 7. STONE PAD INSTALLED AT LOCATION SKIMMER SETTLES (3'X3'X1'D). 8. BAFFLES SHALL BE INSTALLED PERPENDICULAR TO FLOW. UV RESIS 2' MIN. II I I III I I III I I I III I III I I III I l fI DRAWING NOT TO SCALE STANDARD DETAIL NUMBER: HS424 Holly DA TE REVISIONS Springs 7124109 1 Discover The Source. I- LNbI-'tL I IVL VILVV FABRIC DETAIL POROUS BAFFLE INSTALLATION - STEP 2 PIT MINIMUM REQUIREMENTS FOR EDUCATIONAL SIGNAGE FOR USE IN CONJUNCTION WITH STRUCTURAL STORMWATER CONTROL MEASURES PRACTICES MIN. 18"- MAX. 36" Stormwater Control Measure (SCM) This SCM is designed to treat strormwater runoff to reduce the risk of flooding and improve water quality. You can help it function properly by: not dumping trash or yard waste, recycling or safely disposing of pet waste, oil and other chemicals. MIN. 18" This SCM is inspected MAX. 36" and maintained by: (Add owner name and contact information) FOR QUESTIONS AND CONCERNS 0.5" (TYP.) PLEASE CONTACT OWNER Town of Holly Springs Environmental Services and Stormwater Management Division at (919) 567-4011 or at stormwater@hollyspringsnc.us 0.5" DIA. CENTERED MOUNTING: MOUNTING HOLES (2) 1. SIGN SHOULD NOT BE OVER 8 FT TALL AT HIGHEST POINT. 2. SIGN SHOULD BE MOUNTED TO A U-CHANNEL POST (ADD SPECS) OR AFFIXED TO FENCE. NOTE: 1. DECORATIVE SCM EDUCATIONAL SIGNAGE WILL BE REVIEWED ON A CASE BY CASE BASIS. 2. MATERIAL TO BE ALUMINUM, LETTERS TO BE BLACK ON A WHITE BACKGROUND. 3. SIGN SIZE AND MATERIAL MAY BE MODIFIED FOR THE SPECIFIC NEEDS OF THE SCM, BUT SHOULD BE NO SMALLER THAN 18" X 18" AND NO LARGER THAN 36" X 36". DRAWING NOT TO SCALE SCM Educational Signage STANDARD DETAIL NUMBER: H3437 Holly DA TE REVISIONS (s„ Springs TOWN OF HOL L Y SPRINGS ENGINEERING DEPA R TMEN T ' 75 '9 Discover The Source. TABLE 4.2 SEEDING EROSION CONTROL SCHEDULE SLOPES (3:1 AND 2:1 - NOT MOWED) DATE TYPE PLANTING RATE MARCH 1 -JUNE 1 SERICEA LESPEDEZA (SCARIFIED), 50 LBS/ACRE AND MARCH 1 - APRIL 15 ADD TALL FESCUE, 120 LBS/ACRE OR MARCH 1 - JUNE 30 ADD WEEPING LOVEGRASS, 10 LBS/ACRE OR MARCH 1 - JUNE 30 ADD HULLED COMMON BERMUDAGRASS 25 LBS/ACRE JUNE 1 - SEPTEMBER 1 TALL FESCUE, AND 120 LBS/ACRE ADD BROWNTOP MILLET,* 25 LBS/ACRE OR ADD SORGHUM-SUDAN HYBRIDS* 30 LBS/ACRE SEPTEMBER 1 - MARCH 1 SERICEA LESPEDEZA (UNHULLED-UNSCARIFIED), 70 LBS/ACRE AND ADD TALL FESCUE, 120 LBS/ACRE AND ADD ABRUZZI RYE AND ANNUAL RYE 25 LBS/ACRE For temporary seeding purposes. Note on maintenance: refertilize if growth is not fully adequate. Reseed, refertilize and mulch immediately following erosion or other damage. RIPARIAN AREAS TO BE RESEEDED WITH NATIVE SEED MIX. DRAWING NOT TO SCALE DRAWING NOT TO SCALE DRAWING NOT TO SCALE STANDARD DETAIL NUMBER: HS412 STANDARD DETAIL NUMBER: HS409 STANDARD DETAIL NUMBER: HS430 _ Holly Holly STANDARD SKIMMER FIL TER BASIN (PLAN VIEWS - Holly SEEDING EROSION CONTROL SCHEDULE - TABLE 4.2 DA TE REVIS�oIVs ell Springs DA TE REVISIONS4116119 , Springs DA TE REVISIONS Springs Discover The Source. TOWN OF HOLLY SPRINGS ENGINEERING DEPARTMENT TMEN T TOWN OF HOL Y SPRINGS ENGINEERING DEPA TMEN T �� \„ Discover The Source. Discover The Source. 2' MIN 2' MIN COMPACTED CROSS SECTION POSITIVE GRADE 1.0% MAX. - 51AIJILILL UIVLKSIUN UIIL:H WITH TEMPORARY SEEDING AND EROSION CONTROL NETTING 2' MIN. STEEP CUT OR FILL SLOPE P LAN VI EW 3 TIMES I.D. FLAN VILW SECTION 'A -A' NOTES: 1. L = THE LENGTH OF THE RIPRAP APRON. 2. d = 1.5 TIMES THE MAXIMUM STONE DIAMETER BUT NOT LESS THAN 6" (inches). 3. A FILTER BLANKET OR FILTER FABRIC SHOULD BE INSTALLED BETWEEN THE RIPRAP AND SOIL FOUNDATION. I ILI LI\ FABRIC DRAWING NOT TO SCALE STANDARD DETAIL NUMBER: HS417 PIPE OUTLET TO FLA T AREA NO WELL-DEFINED CHANNEL STANDARD DETAIL NUMBER: HS427 DI VERSION DI TCH Springs DA TE o9 REVISIoIVs DA TE REVISIONS (,�, TO WN OF HOL L Y SPRINGS ENGINEERING DEPA R TMEN T ' 24 09 Discover The Source. TO WN OF HOL L Y SPRINGS ENGINEERING DEPA R TMEN T TABLE 4.1 SEEDING EROSION CONTROL SCHEDULE (MAXIMUM SLOPE 3:1) DATE** TYPE PLANTING RATE AUGUST 15 - NOVEMBER 1 TALL FESCUE OR HARD FESCUE 300 LBS/ACRE NOVEMBER 1 - MARCH 1 TALL FESCUE AND ABRUZZI RYE OR ANNUAL RYE 300 LBS/ACRE MARCH 1 - APRIL 15 TALL FESCUE OR HARD FESCUE 300 LBS/ACRE MARCH 1 - JULY 15 HULLED COMMON BERMUDA GRASS 200 LBS/ACRE OR HYBRID BERMUDA GRASS OR CENTIPEDE GRASS OR ZOYSIA GRASS OR ST. AUGUSTINE GRASS APRIL 15 - JUNE 30 WEEPING LOVE GRASS 25 LBS/ACRE OR BAHIA GRASS JULY 15 - AUGUST 15 TALL FESCUE, AND 35 LBS/ACRE BROWNTOP MILLET OR SORGHUM-SUDAN HYBRID* *Temporary - Reseed according to optimum season for desired vegetation. Do not allow temporary cover to grow over 12 inches in height before mowing to keep fescue from being shaded out. **Seeding dates will vary depending on weather conditions (e.g. temperature, rainfall, etc.) Note on maintenance: refertilize if growth is not fully adequate. Reseed, refertilize and mulch immediately following erosion or other damage. RIPARIAN AREAS TO BE RESEEDED WITH NATIVE GRASS MIX/ VEGETATION Holl SEEDING EROSION CONTROL SCHEDULE - TABLE 4. / STANDARD DETAIL NUMBER: HS429 'Hollyg Springs DA TE REVISIONS Springs rin s Discover The s°arcs. TO WN OF HOL L Y SPRINGS ENGINEERING DEPA R TMEN T 9 2' '6 Discover The Source. QO��p60(IS7�0000 C ARO °po 49. 7 -1 o SEAL 3474 S Q N 03 2023 o� •.�I� . �Qoo 0 U 0 � o N L.I U = z }: a .Tj 3 LU U � N <LL-� a- LL N LUOCD a2'-'co U` 2 J x <� fuLL 0 o( -i �- T Ln rn L kD H � oM In rn J w V) 0 2 c� 0 2 0 w > w 2 U Q Z 0 0 0 L7 U7 U7 U7 U7 U7 z z z z z w w w w w 0 2: 2: 2: 2: 2: 1-1 0 0 0 0 0 a U U U U U z z z z z U w 0000 0 C) w w w w w O a a a a a U) U7 U7 U7 U7 U7 z z z z z w 0 0 0 0 0 LUI -I v7 I -I U7 I -I U7 I -I U7 I -I U7 > > > > > ry) ry) ry) ry) ry) N N N N N w 0 0 0 0 CD N N N N N Q 0 m ,-I N ,-I O O O O DATE 0511912023 D RAW N BY T. MORRISOIV DESIGNED BY B. MCLAMB CHECKED BY B HALL SCALE AS SHOWN JOB NO. 54318 SHEET NO. C7.2 o � z _00 Uz V) CD � U� z z 0 o� 0 zo a o E -0 E a- o 0 0-: o 0 z 0 z oz 0 � UQ� o E Qcn > o 0 X-0 z E o V � z E o cn _0 :::) o > N N o L C A tjo6000O0 STEEL FENCE POST WIRE FENCE HARDWARE CLOTH O •w•u•• �f 4 o° •• ,ASS19 • o A� P� �L�GROFILTER � OF 1" WASHED STONEIAMEfER o�(('L� pc °ro a q ; SEAL o Q it 03 023 • G P • 4 O MAX EXTRA STRENGTH FABRIC WITH WIRE FENCE ° 3' FILTER FABRIC °ON GROUND6' oo 0 °Q 6*'IL �O / 6" MIN. Q \� VARIABLE AS DIRECTED BY THE ENGINEER STEEL POST o0g�cbQa�}.{�0 Ojj QQ �Q ell o�Q�00,a °��0�Ou C 0 ° 8�0 1�' (R�O°Od•YTZSO OR2"TO3" .STONE 1� WOVEN WIRE FABRIC U I `AA�\ C+, GEOTEXTILE FABRIC TO STABILIZE FOUNDATION MIN. 12-1/2 GA. SILT FENCE FABRIC INTERMEDIATE BURY WIRE FENCE AND HARDWARE CLOTH II BURY 6" OF UPPER EDGE OF FILTER FABRIC IN TRENCH (ESPECIALL Y IMPORTANT WHERE WETNESS IS ANTICIPA TED) LINE WIRES >00 WIRES 1 I I GRADE )29. SI FENCE F BRIC 3 FILL SLOPE to I I "oD 0 DI VERSION IN TALLE TO ECO D c r Z Ury E �- RIDGE PUBLIC ROAD - SECTION VIEW w z 15, GEOTEXT/LE I I I I GRADE n GRADE 4' MIN. SILT FENCE ~ 3 Q 3 U) U) U) U) U) I 4" WIDE x 8" TRENCH o w ra LU U rV z z z z z - - I OVER SKIRT * a ANCHOR SKIRT AS DIRECTED BY ENGINEER aLL_� 1j rM LU C `CD z O a WWWW � � OU � � OU � � OU � � OU W � � OU z„ �� J x rY U) zz>z>z>z >z FRONT VIEW SIDE VIEW TOP OF SILT FENCE HEIGHTOFSTONE IMUM a 0 o O O O O 0 APPLICABLE AT ALL POINTS OF INGRESS & EGRESS UNTIL SITE IS STABILIZED. NOTE: MUST BE AT LEAST 1' ABOVE THE TOP of THE WASHED STONE �� ' z O W a W a W a W a W a FREQUENT CHECKS OF THE DEVICE AND TIMEL Y MAINTENANCE MUST BE PROVIDED. 1. USE SILT FENCE ONLY WHEN DRAINAGE AREA H Z Z Z Z Z NOTES. DOES NOT EXCEED 1/4 ACRE AND NEVER IN W o > W D O D O O A. TURNING RADIUS SUFFICIENT TO ACCOMMODATE LARGER TRUCKS IS TO BE PROVIDED. AREAS OF CONCENTRATED FLOW. rn � � ~ ~ ~ ~ ~ B. ENTRANCES SHOULD BE LOCH TED TO PROVIDE FOR MAXIMUM UTILIZA TION BY ALL CONSTRUCTION TRUCKS. 2. UV RESISTANT SILT FENCE FABRIC MUST BE USED LQ ORANGE SILT FENCE PERMITTED. J > > > > > LU C.MUST BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR DIRECT FLOW OF TRAFFIC ONTO STREETS FRONT VIEW II ~ °� rY rY rY rY PERIODIC TOP DRESSING WITH STONE WILL BE NECESSARY, KEEP SOME ON HAND. * FOR REPAIR OF SILT BURY WIRE FENCE, D. ANY MA TERIAL WHICH STILL MAKES IT ONTO THE ROAD MUST BE CLEANED IMMEDIA TEL Y. FENCE FAILURES, USE No. 57 WASHED I I FILTER FABRIC, AND HARDWARE STONE. SILT FENCE SHOULD NOT BE U CLOTH IN TRENCH STEEL FENCE POST Uj USED AS INLET SET MAX 2' APART 0 DRAWING NOT TO SCALE PROTECTION AROUND CATCH BASINS. DRAWING NOT TO SCALE MIN. 16" INTO SOLI GROUND DRAWING NOT TO SCALE o _ c� CONSTRUCTION ENTRANCE STANDARD DETAIL NUMBER: H8432 Holly STANDARD TEMPORARY S/L T FENCE STANDARD DETA/L NUMBER. HS401 S/L T FE/VCE OUTLET STANDARD DETA/L NUMBER: HS404 _°Holly DA81JOT s REVISIONS DATE REVISIONS DA TE REVISIONS , Springs Discover The Source ay,``Holly Springs Springs p TO WN OF HOL L Y SPRINGS ENGINEERING DEPA R TMEN T ' 24 09 Discover The Source. ' 6 " ! Discover The Source. ry)N ry)N ry)N ry)N TOWN OF HOLLY SPRINGS ENGINEERING DEPA R TMEN T TO WN OF HOL L Y SPRINGS ENGINEERING DEPA R TMEN T W (V (V (V (V (V N W O O O O O \-i 2 Q O N r) r) U 0 r'') �D�rno ,--i N ,--i O .� o TOP ELEVATION OF STORMWATER 0.5'-1' DATE s' MAX. STEEL POST VARIABLE AS DIRECTED BY THE ENGINEER 1� ----------------------------------------------------------------------------------------------- -- .. r 12" #57 WASHED 1 MAX. STONE 0511912023 Mfl 1 VARIES SCREEN ACCESSIBLE THROUGH DOOR (2' MAX AT CENTER) DRAWN BY WOVEN WIRE FABRIC L L L TREE PROTECTION AREA L L VENT EXISTING SLOPE _ _ _ FE BARRICADE FABRIC MIN. 12-1 /2 GA. L L L DO NOT ENTER L L INTERMEDIATE NOTE: =I1 III I I I T. MORRISO/V = MIN. 10 GA. WIRES 0 o LINE WIRES L L L L SKIMMER IS TO BE A SURFACE DEWATERING DEVICE SUCH AS BMP SKIMMER OR APPROVED CLASS B RIP -RAP FILTER FABRIC DESIGNED BY I 3 L L L L DEVICE. VARIES • r7 N L L L L L L B. MCLAMB • n GRADE L L L L L L L L GRADE SIDE VIEW • CHECKED BY 10 •0 B HALL N ORANGE, UV RESISTANT, HIGH - TENSIL STRENGTH, EXISTING SLOPES SCALE POLY BARRICADE FABRIC (TYPICAL) • AS SHOWN 71 VARIES FLOAT Ir,l�l - IIIr-= SIDE VIEW FRONT VIEW FLEXIBLE JOINTI II�II- II 11111= " (RADIATOR HOSE) ICI"` 6"-1' - H� 40"� -I I NOTES: 1. NO ORANGE SILT FENCE PERMITTED. 4' 2. ORANGE, UV RESISTANT, HIGH-TENSIL STRENGTH, POLY BARRICADE FABRIC MUST BE USED. 3• TREE PROTECTION AREA OUTLET END: CONNECTION TO OUTLET PIPE OR RISER w :WEIR' • � ; KEYED RIP RAP CL 4" 18" BARREL PIPE LONGER THAN SHOWN. 3. WARNING SIGNS TO BE MADE OF DURABLE, WEATHERPROOF MATERIAL. a' DO NOT ENTER NOT INCLUDED WITH SKIMMER SUPPLIED BY USER. _ I ITIT �I-, #57 WASHED STONE (SAME SEE ELEVATION NOTE 3) 4. LETTERS TO BE 3" HIGH MINIMUM, CLEARLY LEGIBLE AND SPACED AS DETAILED. 5. SIGNS SHALL BE PLACED AT 50' MAXIMUM INTERVALS. WARNING SIGN DETAIL 6. PLACE A SIGN AT EACH END OF LINEAR TREE PROTECTION AND 50' ON CENTER THEREAFTER. FRONT VIEW ------------ 7. FOR TREE PROTECTION AREAS LESS THAN 200' IN PERIMETER, PROVIDE NO LESS THAN ONE SIGN PER PROTECTION AREA. 8. ATTACH SIGNS SECURELY TO FENCE POSTS AND FABRIC. NOTES: EXISTING SLOPE -------------------- 1. HEIGHT & WIDTH DETERMINED BY EXISTING TOPOGRAPHY AND SEDIMENT STORAGE REQUIRED. STEP SEQUENCE 9. MAINTAIN TREE PROTECTION FENCE THROUGHOUT DURATION OF PROJECT. 2. KEY RIP RAP INTO THE DAM FOR STABILIZATION. U_ 3. TOP OF DOWNHILL CHECK DAM IS TO BE SAME 10. ADDITIONAL SIGNS MAY BE REQUIRED BY CITY OF RALEIGH INSPECTIONS DEPARTMENT BASED ON ACTUAL FIELD CONDITIONS. ELEVATION OF BOTTOM OF UPHILL CHECK DAM. 7 L 11. PLACE A SIGN AT EACH END OF LINEAR TREE PROTECTION AND 50' ON CENTER THEREAFTER. DRAWING NOT TO SCALE DRAWING NOT TO SCALE DRAWING NOT TO SCALE 0 z STANDARD TREE PROTECTION DETAIL STANDARD DETAIL NUMBER.•HS403 ° Holly Springs STANDARD SKIMMER DETAIL STANDARD DETAIL NUMBER: HS411 - Holly i Springs CHECK DAM STANDARD DETAIL NUMBER: HS413 _ Holly `� Springs DATE REVISIONS DATE REVISIONS DA TE REVISIONS 7124109 ! TOWN OF HOL L Y SPRINGS ENGINEERING DEPARTMENT 7124109 Discover The Source. TOWN OF HOL L Y SPRINGS ENGINEERING DEPARTMENT 9 21 16 �\� Discover The Source. TO WN OF HOL L Y SPRINGS ENGINEERING DEPA R TMEN T Discover The Source. �.9i / \ J V O 0 U) � U J NOTE: PLAN� � ~ 4 5' RETRIEVAL SKIMMER DETAIL COIR FABRIC (TYPICAL) CONTRACTOR SHALL FOLLOW CONSTRUCTION DRAWINGS. PUMP ZONE PROTECT WEIR WITH ROPE (SEE DETAIL HS411) (SEE SHEET 1) SEQUENCE AS NOTED ON CONTRACT z UV RESISTANT TARP WEIR 18" •\\ \\ \\ \\', \\ ////// _ 4j� \\ \\\ \ \ \\ \ 3 a DISCHARGE WITH ACTIVE WORK ZONE STABLE OUTLET REFER TO PLANS SUMP HOLE z o OR ON BEDROCK OR POOL O 0 w • 3 -0 \ ROCK SILT SCREEN Z U ~ EARTH LENGTH sx3'x1s" POLYETHYLENE MEMBRANE ON LEVEL MTH TOP OF BANK FACE 20 MIL THICK OR AS NECESSARY I M � 0 a Z NOTES: 6" STONE APRON STONE PAD WEIR DETAIL (3'x3'x1'D)��'� s ra^Na `\S INTAKE HOSE J 1. USE FOR DRAINAGE AREAS NOT EXCEEDING 5 (FIVE) ACRES.r I TRF \ qM \ Uj 2. EARTH BERM SHALL BE STABILIZED w/SEEDING ACCORDING TO TOWN SPECIFICATIONS. CLASS 1 RIP RAP, NJ BARRIER I DESIGN OF SPILLWAYS DRAINAGE AREA WEIR LENGTHI -? T RlAL ti °rj.(ar C pR OTHER APPROVED t�€A E a�j (r '010 �. (IF 11Sii�IG RIP -RAP pOWt�STREAI�, I \ (ACRES) FT TOP OF DAM ( ) ;a�,tso� �C Apr NO GREATER T3IAN�.B : 1} % arse SLOPE '-`"_ \ } f 1 4.0 2 6.0 3 s.o0" �:;�? fit .,�(� „Xl per' 0% Jn DISCHARGE HOSE HOSE DEWATERING 4 10.0 DITCH AND BURY 5 12.0 TARP EDGE UV RESISTANT TARP � 6�+�,�cr`'s�••�;�ro"1;,;?� 0 . �. r,PIPELINE O✓ v - ,r .� SEDIMENT PUMP �� FLOW - 1 DIMENSIONS SHOWN ARE MINIMUM WEIR LENGTH (MIN. 12" OF FABRIC) O Ja Tau. fT ^��J � SEE PROFILE FOR ;?C ";C> �.•w�- ¢f' , .^. £LE>,j,�T{ON --rJ:O _•; C--:c.'"'r SPECIAL AS NEEDED _ DIVERSION PUMP - - - Q MAINTENANCE INSPECT TEMPORARY SEDIMENT TRAPS AND EMPTY SKIMMER OF ALL DEBRIS AFTER EACH PERIOD OF SIGNIFICANT RAINFALL. REMOVE �i�'F , }r, ^z. C �. ". :-? .9°` STILLING BASIN RAW PUMP WITH ROCK PAD BASE FLOW O SEDIMENT AND RESTORE TRAP TO ITS ORIGINAL DIMENSIONS WHEN THE SEDIMENT HAS ACCUMULATED TO ONE-HALF THE DESIGN DEPTH OF THE TRAP. PLACE THE SEDIMENT THAT IS REMOVED IN A DESIGNATED DISPOSAL AREA AND REPLACE THE CONTAMINATED PART OF -� NOTES: O THE GRAVEL FACING. RAT'5 1 1. WORK AREA TO BE STABILIZED AT THE END OF EACH WORK DAY 2. ROCK SILT SCREENS REQUIRED FOR PUMP AROUND OPERATIONS ARE CHECK THE STRUCTURE FOR DAMAGE FROM EROSION OR PIPING. PERIODICALLY CHECK THE DEPTH OF THE SPILLWAY TO ENSURE IT IS SANDBAGS, CLASS 1 RIP A MINIMUM OF 1.5 FT BELOW THE LOW POINT OF THE EMBANKMENT. IMMEDIATELY FILL ANY SETTLEMENT OF THE EMBANKMENT To OR ETHER NON -ERODIBLE CONSIDERED INCIDENTAL TO PUMPING - SLIGHTLY ABOVE DESIGN GRADE. ANY RIP RAP DISPLACED FROM THE SPILLWAY MUST BE REPLACED IMMEDIATELY. MATERIAL 3. STABLE OUTLET TO CONSIST OF ROCK PLACED IN CHANNEL FOR ENERGY STABILIZE THE EMBANKMENT AND ALL DISTURBED AREAS ABOVE THE SEDIMENT POOL AND DOWNSTREAM FROM THE TRAP IMMEDIATELY AFTER CONSTRUCTION WITH SEEDING. DISSIPATION AND 45' ELBOW INSTALLATION AT THE END OF THE PIPING SO THAT THE WATER DISCHARGES VERTICALLY UP IN THE AIR. THE OUTLET WILL JOB NO. SYOT IETIC FILTER FABRIC COFFER DAM BE APPROVED BY THE DESIGNER PRIOR TO PUMPING. 54318 STANDARD SKIMMER F/L TER BASIN (PROFILE VIEW STANDARD DETA/L NUMBER: HS410 _ €� Holly Springs DA TE REVISIONS SHEET No. C7.3 TYPICAL PUMP AROUND N.T.S. TOWN OF HOLL Y SPRINGS ENGINEERING DEPARTMENT 416 79 �� Discover The Source. o � 0 0o U0 V) o U UU _Q z 0 o � 0 o 0 a 0 E i 0 0 o� 0 0 o � 0 oC: Z 0 o � -o 0 0 Q U of Q� > 0 U 0 0 U X� E 0 V� E U .> o cn 0 0 a 0 > o Q) V) 0 o L DEWATERING CONCRETE BLOCK lei CONSTRUCTION SPECIFICATIONS / v � v IV -_Idli -� 0 49d)090)000-..o0o o � 9 o 1. LAY ONE BLOCK ON EACH SIDE OF THE STRUCTURE ON ITS SIDE IN THE BOTTOM ROW TO ALLOW POOL -� O ° °�00h0' > ( 3D DRAINAGE. THE FOUNDATION SHOULD BE EXCAVATED -� AT LEAST 2 INCHES BELOW THE CREST OF THE STORM DRAIN. PLACE THE BOTTOM ROW OF BLOCKS AGAINST THE EDGE OF THE STORM DRAIN FOR LATERAL SUPPORT AND TO AVOID WASHOUTS WHEN OVERFLOW OCCURS. 2:1 SLOPE, GRAVEL FILTER IF NEEDED, GIVE LATERAL SUPPORT TO SUBSEQUENT ROWS BY PLACING 2 X 4 WOOD STUDS THROUGH BLOCK OPENINGS. WIRE SCREEN 2. CAREFULLY FIT HARDWARE CLOTH OR COMPARABLE TEMPORARY SEDIMENT WIRE MESH WITH 1/2-INCH OPENINGS OVER ALL POOL DEWATERING BLOCK OPENINGS TO HOLD GRAVEL IN PLACE. I -T------------------------------- 3. USE CLEAN GRAVEL, 3/4- TO 1/2-INCH IN DIAMETER, PLACED 2 INCHES BELOW THE TOP _ 16" OF THE BLOCK ON A 2:1 SLOPE OR FLATTER AND 1' MIN. �0 0 -- SMOOTH IT TO AN EVEN GRADE. DOT #57 WASHED 2' MAX. o o �: .... STONE IS RECOMMENDED. _ _ - I III III III- r 11 111 IEI I M I M I I -I I I -I I I -I I I 1 I, II 11=1 11=1 11=1 11=1 11= -I 11-1 I I, � I 111=1 11=111 .: SEDIMENT _III -III a BLOCK AND GRA VEL DROP INLET PRO TEC TION TO WN OF HOL L Y SPRINGS ENGINEERING DEPA R TMEN T NOTES: 1. CONCRETE SHALL NOT CONTACT BOLTS OR ENDS OF MECHANICAL JOINT FITTINGS. 3000 PSI S❑LID CONCRETE SHALL BE USED AS F❑❑TING FOR DUCTILE IR❑N PIPE. t TAF DRAWING NOT TO SCALE STANDARD DETAIL NUMBER: HS421 DA TE I REVISIONS ATE/TAPPING VALVE TOP VIEW SIDE VIEW /E ITTING Holly Springs Discover The Source. V 49,5Ej."'('-.00O0 6 0 -� STANDARD METAL POSTS 2'-0" IN GROUND MAX DISTANCE BETWEEN POSTS 2'. - GALVINIZED HARDWARD WIRE EXTENDS TO TOP OF BOX 0 ° °mac' --- - # 57 WASHED STONE PLACED TO A HEIGHT OF 12"-18" MIN. ABOVE TOP OF BOX DRAWING NOT TO SCALE STANDARD CA TCH BASIN/YARD INLET PROTECTION STANDARD DETAIL NUMBER.- HS422e�� Holly DA TE REVISIONS Springs TO WN OF HOL L Y SPRINGS ENGINEERING DEPA R TMEN T 912116 Discover The Source. APPROVED SEDIMENT FILTERING DEVICE (SEDIMENT FILTER BAG). PROVIDE POSITIVE DRAINAGE FROM SEDIMENT STREAM DIVERSION PUMP FILTER BAG TO STREAM. DISCHARGE HOSES r P DEWATERING PUMP INTAKE HOSE DISCHARGE ONTO STABLE RIPRAP P PAD TO PREVENT : K SCOUR HOLE N MB A / FLW FLOW SEDIMENT INTAKE CLEAN WATER -�...� HOSE SUMP -HOLE FOR POOL DIKE---,.4,DIKE (12" TO 18" DEEP, 2-FT DIAMETER) M. I� WORK AREA LENGTH NOT TO EXCEED THAT �I WHICH CAN BE COMPLETED IN ONE DAY TEMPORARY PUMP AROUND SEQUENCE 1. SET UP PUMP WITH SUCTION AND DISCHARGE HOSE. 2. INSTALL UP -STREAM SANDBAG DAM. 3. INSTALL DOWN -STREAM SANDBAG DAM. 4. THE PUMP MUST RUN CONTINUOUSLY WHILE WORKING IN THE STREAM. 5. STREAMBANKS MUST BE STABILIZED AT THE END OF EACH DAY. NOTES: 1. SANDBAG DIKES SHALL BE SITUATED AT THE UPSTREAM AND DOWNSTREAM ENDS OF THE WORK AREA, AND STREAM FLOW SHALL BE PUMPED AROUND THE WORK AREA. THE PUMP SHOULD DISCHARGE ONTO A STABLE VELOCITY DISSIPATER CONSTRUCTED OF RIPRAP OR SANDBAGS. 2. WATER FROM THE WORK AREA SHALL BE PUMPED TO A SEDIMENT FILTERING MEASURE SUCH AS A SEDIMENT BAG OR OTHER APPROVED DEVICE. THE MEASURE SHALL BE LOCATED SUCH THAT THE WATER DRAINS BACK INTO THE CHANNEL BELOW THE DOWNSTREAM SANDBAG DIKE WITHOUT CAUSING FURTHER EROSION BETWEEN THE SEDIMENT FILTER BAG AND THE STREAMBANK. TEMPORARY PUMP AROUND DRAWING NOT TO SCALE I 4" - 24 STANDARD TAPPING SLEEVE AND VALVE ASSEMBLY STANDARD DETAIL NUMBER: HS628 _ Holly DATE I REVISIONS ,} Springs TOWN OF HOLLY SPRINGS ENGINEERING DEPARTMENT a so 's 1 Discover The Source. z z 0 TOP OF FILL TOP OF FILL TOP OF FILL O CO NOTES: Q H Q Q< Q<� * ZOC=U Z =U W1 (FT.) ELEVATION W2 (FT. PLAN „r FOR�BARVSIZE D 6" THIS PRECAST ENDWALL MAY BE USED FOR THE FOLLOWING fI C3 STANDARDS: 838.01, 838.11, 838.21, 838.27, 838.33, w J �F-1 Z GROUND LINE H GROUND LINE H GROUND LINE - - - - - - - - - - - - - - H- - - - LL J w 1--i z 838.39, 838.51, 838.57, 838.63 AND 838.69. 0 0 C/7 = O 0 Cn 2 * INSTALL PRECAST ENDWALLS WITH WINGS AND PAY W Q Z LL Q = w=rn_n=nr_ am=m=rumour= m=maer_ur= =m=ur_w�ur_ ru �rnser_nr= =ur_m_w�ur_ LLJ Q Q LL FOR IN ACCORDANCE WITH SPECIFICATION SECTION 838. F- U Cr O (.3 !' - _' 711 �' Q U O C3 "' "' F- F-1 a nr nr n 4 * USE 4000 PSI CONCRETE. _ ~ Z w - COMPACT AFTER - COMPACT AFTER F _ z "' PIPE IS PLACED ' - - - 'I" r - _ - '�' PIPE IS PLACED w * PROVIDE ALL REINFORCING STEEL WHICH MEETS ASTM A615 U LL O J = - = _ - = U O J FOR GRADE 60 AND WELDED WIRE FABRIC CONFORMING 0 F1 Q "' u PLACEMENT OF " �� PLACEMENT OF O Q LL j TYPE 2 "' r & PRIOR TO Cr I--1 ° I TO ASTM A185 WITH 2" MIN. CLEARANCE. FILL - •rrr GEOTEXTILE - �_� FILL z fU-I H2 * PLACE LIFT HOLES OR PINS IN ACCORDANCE WITH ap H H I.D./6 MCL NOT IN. "r 00 H * OSHA STANDARD 1926.704. r w0 I.D./6 MIN. rp'- ,=rrr'rrr_rrr�rrI= rrr�rusrrrm THANL6SS rr -rrr=rrr=-rn=rrr =ar- EARTH T w0 1 I.D./6 MIN. - r= _ _ urErrr =rri � H1 PIPE TO BE GROUTED INTO HEADWALL AT JOB SITE BY r 0 NOT LESS THAN 6" 0. D. + 3' NOT LESS THAN 6" 2" PER F007 OF �1� r 0 CONTRACTOR BUT NOT LESS THAN - * ROCK O.D. + 3' NOR MORE THAN 24" 0. D. + 3' ALL ELEMENTS PRECAST TO MEET ASTM C913. NORMAL EARTH FOUNDATION AS DIRECTED By ENGR. WELDED WIRE FABRIC MAY BE SUBSTITUTED FOR REBAR ROCK FOUNDATION 1' -0" * UNSUITABLE MATERIAL FOUNDATION AS LONG AS THE SAME AREA OF STEEL IS PROVIDED. PIPE IN TRENCH * CHAMFER ALL CORNERS 1" OR HAVE A RADIUS OF 1 8" O C (TYP ) TOP OF FILL TOP OF FILL TOP OF FILL °Qo���6OQpppp06�0 1/2 DIAMETER OF PIPE COARSE AGGREGATE (#57) EARTH FILL COVERED BY OR 12" WHICHEVER IS 6" DEEP CLASS B RIPRAP OR SURGE STONE o ��.• SSSIO �oo GREATER 7 o ° q SEAL ; FILTER FABRIC 0 a 34 74 0 fl 03 2�02233�: O I o •. � F .l' - ,Qoo CAPACITY OF PIPE CULVERTS I i II I I I 1- TOGETHER = BANK FULL FLOW `:::::::.: FLOW ELEVATION EARTH FILL COVERED BY CLASS B RIPRAP OR SURGE STONE .. :. COARSE AGGREGATE o c "D 0 N E 00 O O O O Gt O O LLJ z O.oOo°°oo g 000 O ° O o0oppp O 00 _ o. O o.� °d °o o 0 0 O O °0 0 P ° 3 °O �o ° o °O o 00 ° 00 O ° 000 O p � o H o,3 O o° 0 0 0 O o 0 O. O p 0 0 00 0 p 0 O O O 0 o O Q 3 U) U) U) U) U) O .O O O.. O O O. 00 OO O O O O Q O ° .� O O O O U a N Z Z Z Z Z 0 0 0 00 ° 0 0 O O 00 0 0 0 0 0 0 0 O 0c 00 O 0Y w __j W W W W W 00 0 °o 0 00 O 0 ° 0. 0. ° 00 00 �U. °0 Z 0 ° O..o 0 0 O O 0 O. oo CD ° 0. 0 .0 O O .. o O o 0 LLJ N ri O���� � 000 O 00 00 a 00 O 000o OC;°0 0 0° o o 0 °O o0 O a= 00 0 0 0 0 O 0 0.0 0 0 0 O O° 0 .o O° O o°° O ° 0.p O o 0 0 O oo: C� N a; °; a U U U U U 0 0 o O°°0°0o Oo op°0 0.0O o OO, p° 00 ° ° 0o zLU Cr tY ZZZZ Z 0 0. 0 p °� °0 O Q p 0 o O O °O O° o O o� O °b° a x U o° O o O o o O ° O00 ° Q -aQ W 0 0 0 0 O 8�00 0 o p z U) rn W W W W W _ O a a a a a H .E U) U7 U7 U7 U7 U7 00 25 STREAM CHANNEL;" 25 �` o Lu O O O O O MINIMUM MINIMUM U) U) U) U) U) TOP OF BANK TOP OF BANK Lr' °J' > > > > > LU ���� Lu P LAN TEMPORARY STREAM CROSSING TOWN OF HOLL Y SPRINGS ENGINEERING DEPARTMENT DRAWING NOT TO SCALE STANDARD DETAIL NUMBER: HS418 Ho lly DA TE REVISIONS _ Springs 7124109 \� Discover The Source, 10'-0" MIN. HIGH A COHESIVE & LOW FILTRATION SOIL BERM 10 MIL PLASTIC SANDBAGS (TYP.) LINING OCD O O OR STAPLES SIDE SLOPE (TYP.) SANDBAGS (TYP.) O O OR STAPLES HIGH 10'-0" MIN. I COHESIVE & O I O 3'-Q„ O LOW FILTRATION 26" SOIL BERM O O X' MAX <0o O O 2'_0°° 8„ I ,I 2,-0„ /_V \/ y V\ SECTION A -A A PLAN Notes: 1. Actual Location Determined In Field. CLEARLY MARKED SIGNAGE 2. 2. The Concrete Washout Structures Shall Be NOTING DEVICE (18"X24" MIN.) CONCRETE Maintained When The Liquid And/Or Solid Reaches 75% Of The Structures Capacity To WASHOUT provide adequate holding Capacity With A Minimum 12 Inches Of Freeboard. 3. 3. Concrete Washout Structure Needs To Be Clearly Marked With Signage Noting Device. DRAWING NOT TO SCALE ABOVE GRADE WASHOUT STRUCTURE STANDARD DETAIL NUMBER. HS436 Holly A A V V_L'� DA TE REVISIONS (,, _ Springs TOWN OF- HOLLY SPRINGS ENGINEERING DEPAR TMEN T 4 6 " �wc Discover The Source. FLEXIBLE PIPE Round Corrugated Steel Pipe 2 2/3 x 1/2 corrugation ** Diameter Minimum cover Maximum Height of Cover (fleet) inches inches Ga 16 14 12 10 8 �� �� ( } - - 12 12 204 256 15 12 162 204 18 12 135 169 239 21 12 115 145 204 24 12 100 126 178 30 12 79 100 142 36 12 65 83 117 152 42 12 55 70 100 130 160 48 12 48 61 87 113 139 54 12 54 77 100 123 60 12 69 90 111 66 12 81 100 72 12 74 91 78 12 81 J REFER TO CHART Z 84 12 69 FOR BAR SIZE w O NOTE: THE MINIMUM BAR SIZE SHALL BE #5 BARS J y 0 AT 8" CTS.THE CONTRACTOR WILL HAVE THE OPTIONCr SIDE TO INCREASE THIS BAR SIZE AS NEEDED. LL Q o H H H LL a ENDWALL DIMENSIONS FT. MINIMUM MIN./MAX. MIN./MAX. MIN./MAX. MIN./MAX. MIN./MAX. PIPE DIA. BAR SIZE H1(FT.) H2(FT.) D (FT.) W1 W2 1.0 #5 @ 8" 1.25/2.00 2.00/3.75 1.25/1.75 3.00/3.75 5.50/6.00 1.25 #5 @ 8" 1.25/2.00 3.00/3.75 1.25/2.00 3.50/3.75 6.50/6.75 1.50 #5 @ 8" 1.25/2.00 3.00/4.25 1.50/2.50 3.50/3.75 6.50/6.75 2.0 1 #5 @ 8" 1.50/2.50 4.00/4.75 1.75/2.50 4.00/4.25 7.50/8.25 2.5 #5 @ 8" 2.50/3.50 4.00/6.00 2.00/3.00 4.50/5.50 10.00/11.50 3.0 #5 @ 8" 3.00/3.50 5.00/6.00 2.75/3.50 5.25/5.75 11.50/11.75 3.5 #5 @ 8" 3.25/4.50 6.00/6.75 3.25/3.50 6.00/6.75 12.00/13.25 4.0 #5 @ 8" 3.50/4.50 6.50/7.00 3.25/3.50 6.50/6.75 13.00/13.25 4.5 #5 @ 8" 4.00/5.00 6.50/8.50 3.25/4.00 7.00/9.25 13.50/15.75 5.0 #5 @ 8" 4.50/5.00 7.00/8.50 3.25/4.00 7.25/9.25 13.75/15.75 5.5 #5 @ 8" 4.50/5.00 7.50/8.50 3.25/4.00 7.25/9.25 14.00/15.75 6.0 #5 @ 8" 4.50/5.00 7.50/8.50 3.25/4.00 7.75/9.25 14.75/16.75 CD 3 0) - CD J H Z GROUND LINE GROUND LINE ZUJ Q MIN. O.D. MIN. O.D. MIN. O.D. MIN. O.D. MIN. O.D. W Q d GROUND LINE - _ - _ - - _ TYPE 2 _ - - _ - _ - r H o - - --� :1 �• - GEOTEXTILE •1 �• Q aC LU , , Z W HOPE * (Minimum fill) 2' for pipe diameters >_ 12" and < 60" 0 -"'-"_"'=' "_"'_"' 0 * (Maximum fill) 20' for pipe diameters <_ 24" =M-ur=r •.=rrGrn=rn _rn=W=ru 7•. _ COMPACT AFTER T.•.••... .. 0 ~ N - _ -PIPE IS PLACED „r 0 ~ 17' for pipe diameters >_ 30" and <- 60" W r` _ _ & PRIOR TO W 0 � I.D./6 MIN. •. _ PLACEMENT OF - • •• - 0 QNOT LESS THAN 6" ur_rn=nr=rn=ur_ ur_rn_ur FILLur=rn=rp_ru=ur_ ,q_rrr_rn Q a 0 PVC - * (Minimum fill) 2' for pipe diameters >_ 12" and -< 36" I.D./6 MIN. �AS DIRECTED 0 * (Maximum fill) 30' for pipe diameters >_ 12" and -< 36" Z Z = NOT LESS THAN 6" MIN. O.D. MIN. O.D. BY ENGINEER COMPACT AFTER O.D. + 2' NOT LESSTHAN6" O.D.+ 2' Q ~ 1--1 Q O � PIPE IS PLACED F- & PRIOR TO 1/2" PER FOOT OF 'H' I- Q. I= U) N PLACEMENT OF BUT NOT LESS THAN 12" U) * FILL HEIGHT IS MEASURED FROM THE TOP OF THE PIPE FILL NORMAL EARTH FOUNDATION ROCK FOUNDATION NOR MORE THAN 24" UNSUITABLE MATERIAL FOUNDATION LPL TO THE BOTTOM OF THE PAVEMENT STRUCTURE >" II-_ T PIPE ABOVE GROUND �" O Round Corrugated Aluminum Pipe 2 2/3 x %2 corrugation ** Diameter Minimum cover Maximum Height of Cover (feet) inches inches (Ga) 16 14 12 10 8 12 12 123 155 218 281 344 15 12 98 123 174 224 275 18 12 81 102 144 187 228 21 12 69 87 123 160 195 24 12 60 76 108 139 171 27 12 67 95 123 151 30 12 60 85 111 136 36 12 50 71 92 113 42 12 60 78 96 48 12 52 68 84 54 12 46 50 74 60 12 50 62 66 12 51 72 12 41 * FOR DIFFERENT CORRUGATIONS AND ARCH PIPES REFER TO ROADWAY DESIGN MANUAL OR MANUFACTURERS SPECIFICATION. REFER TO THE FOLLOWING FOR PIPE SPECIFICATIONS CSP AASHTO M36 CAAP - AASHTO M196 HOPE - AASHTO M294 PVC ASTM F949 or AASHTO M304 NOTES: FILL HEIGHTS SHOWN WERE CALCULATED USING AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS 1' MINIMUM COVER FOR ALL SIDE DRAIN PIPE IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS < _j Q 9 RIGID PIPE 0 0 Q v H GENERAL NOTES: 0 G Q O LU U)I.D. DO NOT OPERATE HEAVY EQUIPMENT OVER ANY PIPE CULVERT UNTIL THE PIPE CULVERT HAS = THE MAXIMUM HORIZONTAL INSIDE DIAMETER DIMENSION. BEEN PROPERLY BACKFILLED AND COVERED WITH AT LEAST 3 FEET OF APPROVED MATERIAL. RCP - * Minimum fill) 1' for Class IV & CLASS V ( ) 0 2' for Class III & Class II REFER TO THE FOLLOWING FOR PIPE SPECIFICATIONS = O.D. = THE MAXIMUM HORIZONTAL OUTSIDE DIAMETER DIMENSION. - - - - - SPRINGLINE OF PIPE WrE O H = THE FILL HEIGHT MEASURED VERTICALLY AT ANY POINT SELECT BACKFILL MATERIAL CLASS III OR CLASS II, * (Maximum fill) 10' - Class II pipe ® BELOW SPRINGLINE. 2O' - Class III pipe ALONG THE PIPE FROM THE TOP OF THE PIPE TO THE TOP OF THE EMBANKMENT AT THAT POINT. 30' - Class IV pipe APPROVED SUITABLE LOCAL MATERIAL ABOVE SPRINGLINE. ® 40' - Class V pipe TAKE CARE TO FULLY COMPACT HAUNCH ZONE OF PIPE BACKFILL. nFrrr- rrr-rr UNDISTURBED EARTH MATERIAL (For fills > 40' & < 80' use LRFD Direct Design Method) LOOSELY PLACED SELECT MATERIAL CLASS III OR CLASS II, TYPE 1 SELECT MATERIAL CLASS V OR VI FOR FOUNDATION CONDITIONING. ENCAPSULATE FOR PIPE BEDDING. LEAVE SECTION DIRECTLY BENEATH PIPE WITH TYPE 2 GEOTEXTILE AS DIRECTED BY THE ENGINEER. UNCOMPACTED AS PIPE SEATING AND BACKFILL WILL ACCOMPLISH COMPACTION.11 * FILL HEIGHT IS MEASURED FROM THE TOP OF THE PIPE TO THE BOTTOM OF THE PAVEMENT STRUCTURE SHEET 1 OF 1 SHEET 2 OF 3 3p.pO 838.80 OO.O1 300.01 RCP - AASHTO M170 NOTES: FILL HEIGHTS SHOWN WERE CALCULATED USING AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS 1' MINIMUM COVER FOR ALL SIDE DRAIN PIPE IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS z O Cn H < Q Q F, 0 U LLJ�1-IZ O O Cn 2 wQQw2 QUCC0c.D H (1) LL 0 O Cr O Cf) Z ,jam J� C H wo 1 0 Z O H U_aLL J CD ~ Q LU J NDO �"■ 0 Z H 0CC H oa Z H W F- a = U7 J Q O LL. 0 = CC �„■ LU G BEET 3 OF 3 300.01 ry) ry) ry) ry) (V (V (V (V (V W C:) 0 0 0 0 (V (V (V (V (V 0 (y) , -i N , -i O to 00 O O i 0 0 0 .-i .-i DATE 0511912023 D R.AW N BY T. 1V0RRIS01V DESIGNED BY B. MCLAMB CHECKED BY B HALL SCALE AS SHOWN H� H4 Z ■ LL z I -I 0 z U ° U) Q J 1 U 0 LLJ C) z 06 O � IVI JI W z %0 Q j L J Uj zuu III 30B NO. 54318 SHEET NO. C7.4 o� -Do UCL O UU� �z O o� O x O O E -0 E C1 a � Q O O 0:� o 0 n E z O :� o 0 0 Q � O Q � N 0 O O X X � 2 E �0 V) L- SECTION 11.00 RECLAIMED WATER DISTRIBUTION SYSTEM TABLE OF CONTENTS 11.00 GENERAL 11.01 RECLAIMED WATER DISTRIBUTION PIPE A.. Design B. Materials C. Installation 1.1.02 VALVES AND APPURTENANCES A. Valves B. Appurtenances 11.03 RECLAIMED WATER SERVICE TAPS A. Design B. Materials 11.04 RECLAIMED WATER IRRIGATION SYSTEMS A. General B. Designs C. Street Crossing D. Hose Bibs E. Rain Sensors 11.05 TESTING AND INSPECTION A. General B. Testing C. Inspection D. Cross Connection Control ,►►►i►ii1'fI/�f` 1.1.06 REPAIR OF RECLAIMED WATER SYSTEM 2015 ED&CS 1 t-1 Supp ii 9 Dec. 2023 11.00 GENERAL A. All aspects of the design and construction of any portion of the reclaimed water distribution system shall, at a minimum, meet the requirements of the North Carolina Department of Environmental Quality (NCDEQ) Division of Water Resources (DWR). Requirements presented in the Town of Holly Springs Standard Specifications hereunder that are more restrictive or go above and beyond the requirements of DWR are required by the Town of Holly Springs. B. All Reclaimed water systems must be designed per North Carolina Administrative Code Title 15A (15A NCAC) — Environmental Quality, Subchapters 02T, 02U, and 18C latest revisions, the governing regulations. C. Extensions of the existing reclaimed water distribution system must adhere to any and all Policy Statements and/or Master Plans pertaining to the reclaimed water distribution system and receive prior approval from the Executive Director of Utilities and Infrastructure Services, prior to consideration. D. Reclaimed water main extensions may require a detailed hydraulic report, signed and sealed by a North Carolina Professional Engineer, be submitted to the Executive Director of Utilities and Infrastructure Services and receive approval prior to construction drawing submittal. E. All utility extension permits must be obtained prior to construction. Refer to the Town Code of Ordinances Section 16 for further requirements. F. Reclaimed water shall be utilized and distributed in accordance with 15A NCAC 02U Sections .0500 through 0.0700. G. Any reclaimed water that leaves the reclaimed water distribution system other than by means of a properly permitted use must be disposed of into the Town of Holly Springs sanitary sewer system. This includes any reclaimed water line flushing, and/or line breaks unless otherwise allowed by NCDEQ rules. Deminimus runoff from distribution air relief valves and blow -off is deemed permitted per NCDEQ rules. Any reclaimed water that is not a properly permitted use or sent to a sanitary sewer must be reported and handled as if it were a wastewater spill. 11.01 RECLAIMED WATER DISTRIBUTION PIPE All new irrigation systems located within the Town's reclaimed service area desiring to obtain water service for such system from the Town must connect to the reclaimed water system, if reclaimed water is available to the property. Design must be in accordance with Chapter 16 Article IV of the Holly Springs Town Code of Ordinances. These areas are shown on the Reclaimed Water Distribution Service Area Map located on the Town's web site. 2015 ED&CS 11-2 Supp # 9 Dec. 2023 A. DESIGN 1. Location: Reclaimed water lines shall be extended along the roadway to the adjacent property line. All public reclaimed water mains shall be located within dedicated right of way or dedicated easements with a minimum width of 20 feet. See Section 2.10 for allowable landscape plantings within a Town of Holly Springs easement. 2. Sizing: Reclaimed water mains shall be sized in accordance with good design procedures to provide adequate pressures throughout the system or as directed by the Executive Director of Utilities and Infrastructure Services. The minimum pipe size for reclaimed water mains shall be 4 inches in accordance with the reclaim hydraulic model. 3. Installation: All utility extension permits must be obtained prior to construction utilizing appropriate application forms from NCDEQ and/or the town. All reclaimed water mains shall have a minimum cover of 4 feet measured from the top of the pipe to the finished grade. When reclaimed water mains are installed along a roadway which does not have curb and gutter, the reclaimed water main shall be installed at sufficient depth to prevent conflict with future road improvements or vertical alignment changes. 4. Relation to Potable Water Mains and Other Utilities a) Reclaimed water distribution lines shall be located at least 10-feet horizontally from any water line, unless local conditions or barriers prevent a 10-foot lateral separation. If these separation distances cannot be met, the piping and integrity testing procedures shall meet water main standards in accordance with 15A NCAC 18C. Reclaimed water distribution lines shall meet the separation distances to sewer lines in accordance with 15A NCAC 02T .0305. b) Reclaimed water mains should only cross sanitary sewer mains or potable water mains at an approximate 90 degree angle. d) The minimum separation between reclaimed water mains and storm sewer mains must be either 5 feet horizontal or 2 feet horizontal with a vertical separation of 24 inches unless otherwise approved by the Executive Director of Utilities and Infrastructure Services. Where storm sewers cross reclaimed water with a vertical separation of less than 24 inches the segment of reclaimed water pipe shall be ductile iron pipe at least one whole pipe length from the crossing point with joints equivalent to water main standards. 2015 ED&CS 11-3 Supp # 9 Dec. 2023 e) Where reclaim water main crosses under storm sewer main with a vertical separation less than 24 inches then reclaim water must be ductile iron minimum of 10 feet each side of crossing and properly marked as reclaim. f) Where sanitary sewer crosses reclaimed mains, a vertical separation of 18 inches must be maintained. g) Reclaimed water distribution lines shall not be less than 50 ft from a well unless the piping and integrity testing procedures meet water main standards, but in no case shall they be less than 25 feet from a private well or 50 ft from a public well. 5. Identification of Reclaimed Pipes a. General: All new distribution piping in the reclaimed water system, including service lines, valves and other appurtenances should either be colored purple (Pantone 522 or similar) and embossed or be integrally stamped/marked "CAUTION: RECLAIMED WATER — DO NOT DRINK," or be installed with a purple identification tape, and a purple polyethylene vinyl wrap. b) Polyethylene Wrap: Buried ductile iron pipe and fittings shall be wrapped with a purple colored polyethylene membrane conforming to ANSI A21.5, and installed in accordance with AWWA C105. The polyethylene sheets shall be 8 mils thick, minimum, and be colored purple (Pantone 522 or similar). c) Tracer Wire: Tracer wire shall be installed on all reclaimed piping. Tracer wire shall be installed as shown in the Details. Approved Wire Connectors shall be used to attach wire together. d) Identification Tape: Identification tape should be prepared with white or black printing on a purple field (Pantone 522 or similar) having the words "CAUTION: RECLAIMED WATER — DO NOT DRINK." The overall width of the tape should be at least 3 inches. ii. Identification tape should be installed on the top of the distribution piping longitudinally and should be centered over the pipe. The identification should be continuous in its coverage on the pipe and should be fastened to each pipe length no more than 10 feet apart. Tape attached to sections of pipe before they are placed in the trench should 2015 ED&CS 11-4 Supp # 9 Dec. 2023 have flaps sufficient for continuous coverage. Other satisfactory means of securing the tape during backfill of the trench may be used if suitable for the work, as determined by the Executive Director of Utilities and Infrastructure Services. iii. The identification tape differentiating the reclaimed water piping from other utility lines should be consistent throughout the service area. e) Signage: i. The public shall be notified of the use of reclaimed water. ii. Advisory signs shall be posted around reclaimed water irrigation activities in public areas, adjacent to ponds used to store reclaimed water in public areas, and at decorative water features that use reclaimed water. iii. All advisory signs should be colored purple (Pantone 522 or similar), should read "CAUTION: RECLAIMED WATER — DO NOT DRINK," The sign shall reference the TOHS Utilities and Infrastructure Services Department. Additionally, signage shall provide emergency number of 919-577-1090 and the Town's web site. B. MATERIALS 1. Material: All reclaimed water main distribution pipe 4" thru 12" diameter shall be C900 PVC pipe. All reclaimed water main distribution pipe greater than 12" diameter shall be C905 PVC. Ductile Iron Pipe shall only be used in special cases and with the Executive Director of Utilities and Infrastructure Services approval. New manufacturers must submit requests for approval to the Executive Director of Utilities and Infrastructure Services. Additional information such as catalogs, list of installations in the area or material samples may be required. A written response will be mailed to the applicant accepting or rejecting the product within 90 days of the receipt of all necessary information. 2. Ductile Iron Pipe: a) This material shall only be used for reclaimed water lines with Executive Director of Utilities and Infrastructure Services' approval. b) Buried ductile iron pipe and fittings shall be wrapped with a purple colored polyethylene membrane conforming to ANSI A21.5, and installed in accordance with AWWA C105. The polyethylene sheets shall be 8 mils thick, minimum, and be colored purple (Pantone 522 or similar). c) Ductile iron pipe shall be designed and manufactured in accordance with AWWA C150 and C151. The minimum required pressure ratings for ductile iron pipe installed at a Type 2 laying condition are tabulated below. For all 2015 ED&CS 11-5 Supp # 9 Dec. 2023 other installations other than specified, the laying condition or the minimum pressure class rating shall be increased in accordance with AWWA C151. Pipe Diameter Depth of Cover Pressure Class 6-8 -inch 3-20 feet 350 psi 10-12 -inch 3-14 feet 350 psi 14-20 -inch 3-10 feet 250 psi 24-64 -inch 3 - 8 feet 150 psi d) Pipe joints shall be of the push -on type as per AWWA C111. Pipe lining shall be cement mortar with a seal coat of bituminous material in accordance with AWWA C104. Galvanized steel pipe will not be allowed as a material for reclaimed water mains or reclaimed water service lines. 3. PVC Pipe: a) PVC pipe (4" to 12") shall be designed and manufactured in accordance with AWWA C900. PVC pipe larger than 12" shall be designed and manufactured in accordance with AWWA C905. The PVC pipe shall be made of virgin PVC resin that provides chemical and physical properties that meet or exceed cell class 12454-B as defined in ASTM D 1784. All PVC pipe shall be supplied in standard laying lengths of 20 feet. Pipe shall be furnished in factory packaged units, with each joint plainly marked with the manufacturer's name, pressure class, size, etc. PVC pipe shall have integral wall, bell and spigot joints fabricated with elastomeric gaskets that meet or exceed the performance requirements of ASTM D3139 and F477. Fittings used on PVC pipe shall be AWWA C153 compact ductile iron fittings. b) All PVC pipe supplied for reclaimed water applications shall be color coded purple (Pantone 522 or similar) as required by 15A NCAC 02U — Reclaimed Water). c) Furnish pipe for the following minimum pressure classes as indicated. Diameter 4"-12", C900 Pressure Class 150, SDR 18 Diameter 14" and larger, C905 Pressure Class 165, DR18. 4. Steel Encasement for reclaimed water pipes are required for the following Street Classifications to avoid traffic disruption in the future: • Controlled Access Highway For carrier pipes that employ cathodic protection anticorrosion systems, the carrier and casing pipes shall be effectively insulated from one another. Carrier and casing shall be cathodically protected as a unit. See Section 5.03 Boring and Jacking for more casing pipe size requirements. 2015 ED&CS 11-6 Supp # 9 Dec. 2023 C. INSTALLATION Ductile iron pipe shall be installed in accordance with the requirements of AWWA C600 and the Ductile Iron Pipe Handbook published by the Ductile Iron Pipe Research Association. At a minimum, all ductile iron pipe shall be installed at a Type 2 laying condition as specified by AWWA C600. 2. PVC pipe shall be installed in accordance with AWWA C605. At a minimum, all PVC pipe shall be installed at a Type 3 laying condition as specified by AWWA C605. 3. Materials at all times shall be handled with mechanical equipment or in such a manner to protect them from damage. At no time shall pipe and fittings be dropped or pushed into ditches. 4. Pipe and fitting interiors shall be protected from foreign matter and shall be inspected for damage and defects prior to installation. In the event foreign matter is present in pipe and fittings, it shall be removed before installation. Open ends of pipe shall be plugged or capped when pipe laying is not in progress. All pipes shall be in nominal lengths of eighteen or twenty feet and shall be installed with at least 48 inches of cover below the finished subgrade. Pipe shall be laid on true lines as directed by the Executive Director of Utilities and Infrastructure Services. Trenches shall be sufficiently wide to adjust the alignment. Bell holes shall be dug at each joint to permit proper joint assembly. The pipe shall be laid and adjusted so that the alignment with the next succeeding joint will be centered in the j oint and the entire pipeline will be in continuous alignment both horizontally and vertically. Pipe joints shall be fitted so that a thoroughly watertight joint will result. All joints will be made in conformance with the manufacturer's recommendations for the type of joint selected. All transition joints between different types of pipe shall be made with transition couplings approved on shop drawings showing the complete assembly to scale. 6. Prior to beginning construction, the Contractor shall contact local utility companies and verify the location of existing utilities. The Contractor shall be completely and solely responsible for locating all existing buried utilities inside the construction zone before beginning excavation. The Contractor shall be solely responsible for scheduling and coordinating the utility location work. When an existing utility is in conflict with construction, it shall be exposed prior to beginning construction to prevent damage to the existing utility. 7. Valves in the existing Town of Holly Springs water system shall not be operated without a minimum notice of 24 hours to the Executive Director of Utilities and Infrastructure Services and the Director of Public Utilities. The Contractor shall 2015 ED&CS 11-7 Supp # 9 Dec. 2023 operate valves only in accordance with Town of Holly Springs Engineering Design and Construction Standards. 11.02 VALVES AND APPURTENANCES A. VALVES 1. General a) Valves shall be installed on all branches from feeder reclaimed water mains according to the following schedule: 4 valves at crosses; 3 valves at tees. When a loop section of reclaimed water line is connected back into the feeder reclaimed water main within a distance of 200 feet or less, only one valve will be required in the feeder reclaimed main. Reclaimed water main extensions or mains extending at a project phase line shall include a valve and one additional standard length of pipe with a cap and a temporary blow -off assembly. b) Where no reclaimed waterline intersections are existing, amain line valve shall be installed at every 100 feet per 1-inch diameter main up to a distance of 1000 feet between valves. In addition, the Town of Holly Springs reserves the right to require additional isolation valves where necessary for efficient operation and maintenance. c) Valves shall be properly located, operable and at the correct elevation. All valves and reducers shall be rodded to the tee or cross if one is located within 10 feet as shown in the Details. If reducers cannot be rodded, concrete blocking or other restraining methods will be required. The maximum depth of the valve nut shall be 5 feet. When valve extension kits are used, they must be manufactured by the same company which manufactured the valve. 2. Combination Air Valves a) Combination air valves shall be installed at all high points of reclaimed water lines 12" inches in diameter or larger and at other locations as directed by the Town of Holly Springs. The reclaimed water main shall be installed at a grade which will allow the air to migrate to a high point where the air can be released through an air valve. A minimum pipe slope of 1 foot in 500 feet should be maintained. The valve shall have a minimum two (2) inch NPT inlet and 200- PSIG working pressure. Combination air valves shall be sized by the Engineer and approved by the Town of Holly Springs. b) Combination air valves shall be of the single housing style that combines the operation of both an air/vacuum and air release valve. The valve must meet the requirements of AWWA C512 and be installed in accordance with the Details. 2015 ED&CS 11-8 Supp # 9 Dec. 2023 c) Manholes installed for the combination air valves shall meet all requirements of Section 7.00. Crate Valves a) Gate valves 2 inches and greater shall meet all requirements of AWWA C500 for a working pressure of 200 psi. All gate valves shall be mechanical joint with iron body, bronze mounting double disc parallel seat type with a non -rising stem and open left with a double O-ring seal. b) Gate valves, up to and including 12 inches, shall be installed in a vertical position. c) Gate Valves 16 inches and larger must be approved by the Executive Director of Utilities and Infrastructure Services. They may be installed horizontally and equipped with bevel gears, grease case, rollers, tracks scrapers, and a bypass located on the side of the body (fully revolving disc valves shall not require rollers), or vertically and be equipped with spur gears enclosed in a grease case and with a bypass located on the side of the body. In either case, the roller and scraper operators shall be installed in a manhole that meets all requirements of Section 7.00. 4. Resilient Seat Wedge Gate Valves: Resilient seat wedge gate valves shall be manufactured in accordance with AWWA C509 for a working pressure of 200 psi. All shall be mechanical joint with iron body, open left with a non -rising stem and two O-ring stem seals. All ferrous surfaces, both inside and outside, shall be protected by a fusion -bonded epoxy coating. Butterfly Valves: Butterfly Valves may be installed in reclaimed water mains 24 inches or greater with the permission of the Executive Director of Utilities and Infrastructure Services. All butterfly valves shall meet the requirements of AWWA C504 with mechanical joints, 2 inch open left operating nut. Valves installed on reclaimed waterlines at depths greater than 6' (measured to top of pipe) shall be installed in a manhole (see Section 7.00) as shown in the Details. Valves designated by the Town of Holly Springs to potentially have a remote actuator shall be installed in a manhole (see Section 7.00) as shown in the Details. 6. Valve Boxes a) Valve boxes shall be cast iron, screw or telescopic type, with a 5-inch opening. Valve box ring adjustments will not be allowed. All valve boxes shall be furnished with an approved operating key which shall allow operation by authorized personnel only. b) Valve box covers shall be square in shape (NOT round) and shall be designed for AASHTO H-20 truck loadings. All valve box covers shall be of non- 2015 ED&CS 11-9 Supp # 9 Dec. 2023 interchangeable shape with potable water covers, and cast on the top surface with a recognizable inscription indicating "Reclaimed Water". All valve box covers shall be painted purple (Pantone 522 or similar). c) The valve box shall be centered over the wrench nut and seated on compacted backfill without touching the valve assembly. All valve boxes shall be encased in a trowel finished 2' x 2' x 6" pad of 3000-psi concrete beneath the asphalt with the cover flush with the top of the pavement or flush with the finished grade. Precast concrete valve box encasements may not be used for valve box encasement outside of paved areas. The maximum depth of the valve nut shall be 5 feet. When valve extension kits are used, they must be manufactured by the same company that manufactured the valve. B. APPURTENANCES 1. Pipe Fittings: Pipe fittings shall be castor ductile iron designed and manufactured as per AWWA C110. Sizes of fittings up to and including 12 inches shall be designed for an internal pressure of 250 psi, and larger size fittings shall be designed for an internal pressure of 150 psi. Compact ductile iron mechanical joint fittings designed and manufactured as per AWWA C111 are also acceptable. Joints for fittings shall be mechanical and lined with cement mortar with a seal coat of bituminous material, all in accordance with AWWA C104. 2. Blowoffs a) Blowoffs installed at the end of cul-de-sacs shall be a minimum of 2 inches. Blowoffs installed on transmission and distribution mains shall be a minimum of 2 inches. Where there is not sufficient pressure to thoroughly flush the system, a larger blowoff will be required. b) Blowoff assemblies shall be constructed as shown in the Details. The valves shall be gate type with a non -rising stem and a 2-inch operating nut, O-ring seals and screwed ends. A full-size valve is required on mains that are planned to be extended. c) Blowoffs shall be directed in a non -erosive manner to a stabilized grassed area at least 50 ft. from a jurisdictional feature or directed into the closest sanitary sewer manhole. Blowoffs installed at the end of cul-de-sacs should be tied into a sanitary sewer manhole where available. 3. Thrust Restraint: Reaction blocking for all fittings or components subject to hydrostatic thrust shall be securely anchored by the use of concrete thrust blocks poured in place or restrained joint piping as described below a. Concrete thrust blocks shall be poured in place with reaction areas as shown in the Details. No concrete shall interfere with the removal of fittings. Material for reaction blocking shall be 3000 psi concrete. A minimum 4 mil plastic shall 2015 ED&CS 11-10 Supp # 9 Dec. 2023 cover the fitting to ensure that no concrete will interfere with removal of the fitting. b. PVC Bell Joint Restraint - All PVC bell joints shall be restrained for both C900 and C905 PVC pipe. The bell joint restraint shall consist of either an approved restrained PVC joint provided by the same manufacturer of the PVC pipe or an approved bell joint restraint harness. All bell joint restraint harness assemblies shall be made of ductile iron pipe (DIP), coated with a manufacturer applied epoxy coating or polyester powder coating, including stainless steel bolts, nuts and rods. The bell joint restraint harness shall be manufacturer approved for use with PVC pipe and rated for at least 200-psi with a 3:1 safety factor. c. All valves and fittings shall be restrained to C900 or C905 pipe with an approved wedge action retainer gland or other approved restraining method. All DIP fittings for reclaimed water use shall be identified by purple painting or wrapping with polyethylene wrap (Pantone 522 or similar). Alternative restraining methods and mechanical joint restraints may be used upon approval by the Executive Director of Utilities and Infrastructure Services. 11.03 RECLAIMED WATER SERVICE TAPS A. DESIGN Individual reclaimed water services, and multiple branch services, shall be provided from the reclaimed water main to each reclaimed water meter for single customer locations in accordance with the Details. All connections shall be made by wet taps. Service connections shall be made perpendicular to the reclaimed water main and shall run straight to the reclaimed water meter. 2. All reclaimed water meter boxes and vaults shall be located at the edge of the serviced lot's right of way or easement. Reclaimed water meter boxes shall not be placed in streets, sidewalks, parking areas or obstructed by fencing or buildings. Exceptions to these conditions will be at the direction of the Executive Director of Utilities and Infrastructure Services. 3. Service taps to existing reclaimed water mains shall be made by the Town of Holly Springs. Service taps to new reclaimed water mains shall be made by the Contractor in accordance with the Specifications. 4. Water meters shall be sized based on applicant water budget calculations using the approved method. Water meter size shall be determined from the following table; or as otherwise specified by the Executive Director of Utilities and Infrastructure Services. Multiple branch services size shall be determined by the designer. 2015 ED&CS 11-11 Supp # 9 Dec. 2023 METER SIZING GUIDE Meter Size Flow Range inches GPM 3/4" PD 0 - 20 I" PD 20-50 11/2"PD 50- 100 2" C 100 - 200 3" C 200 - 400 4" C 400 - 600 PD = Positive Displacement T = Turbine (may be required on a case -by -case basis) C = Compound (must be sized on a case -by -case basis) 5. Service taps greater than 2 inches shall be made by a Contractor of the Developer. B. MATERIALS Direct taps shall not be allowed on C900 or C905 PVC mains. The maximum allowable size for saddle taps is 2". All taps larger than 2-inches shall be installed by inline fittings or tapping sleeves. All tapping of C900 or C905 PVC mains shall be implemented with shell type cutting tools classified for use with PVC pipe that retains the coupon cut while penetrating the pipe wall, use of twist drill bits and auger bits shall be prohibited. The maximum size of direct taps without a fitting, tapping sleeve or saddle for ductile iron mains shall be as follows: Main Size inches Tap Size inches 4" main 3/4" to 6" main 1" to 8" main 1 1/4" to 10" main 1 1/2" to 12" main 2" to 2. Tapping Sleeves: Tapping Sleeves shall be made of either cast iron or stainless steel. The sleeve shall be two-piece with mechanical joint to the main line and flanged to the tapping valve. Cast iron shall meet AWWA C110 2015 ED&CS 11-12 Supp # 9 Dec. 2023 specifications. Stainless steel shall meet AWWA C223 specifications. All sleeves shall require full circumferential gasket. All tapping sleeves shall be manufactured and approved for installation on the specific main line pipe material (DIP, C900, C905). 3. Tapping Saddles: Tapping Saddles shall be used on reclaimed water mains 16 inches and larger. Saddles shall be made of ductile iron providing a factor of safety of 2.5 with a working pressure of 250 psi. Saddles shall be equipped with an AWWA C110 flange connection on the branch. Sealing gaskets shall be O-ring type, high quality molded rubber having an approximate 70 durometer hardness, placed into a groove on the curved surface of the saddles. Straps shall be alloy steel. The maximum size saddle outlet for each size of pipe to be tapped shall be as follows: Size pipe to be tapped Maximum size Saddle Outlet 16" 8" 18" 8" 20' 10" 24" and larger 12" 4. Corporation Stops: Corporation Stops shall be ball type, made of brass and complete with a compression or flared coupling and AWWA Standard threads as per AWWA C800. Taps shall be located at 10:00 or 2:00 o'clock on the circumference of the pipe. Service taps shall be staggered alternating from one side of the reclaimed water main to the other and at least 12 inches apart. The taps must be a minimum of 24 inches apart if they are on the same side of the pipe. No burned taps will be allowed and each corporation stop will be wrapped with Teflon tape for ductile iron pipe reclaimed water mains. No tapping shall be made where rodding is placed. 5. Service Saddles: Service saddles shall be bronze body (85-5-5 waterworks brass) and double strap for taps with silicon bronze nuts conforming to ASTM A98 and factory installed grade 60 rubber gaskets. Service saddles shall be approved by the manufacturer for use on C900/C905 PVC mains. 6. Service Tubing: Copper service tubing shall be type K soft copper tubing per ASTM B88. No union shall be used in the installation of the service connection of 100-feet or less. The longest available length of service line shall be used with no unions (e.g. for 3/4 inch, only 1 union will be allowed for each 100 foot section). Unions shall be made with flare or compression type couplings. Copper service tubing shall be installed reclaimed locating tape, spirally wrapped from the tap through the setter. 7. Coppersetters for 3/4 and 1-inch Reclaimed Water Services: All 3/4 and 1-inch reclaimed water services shall be installed with coppersetters as shown in the 2015 ED&CS 11-13 Supp # 9 Dec. 2023 Details. All coppersetters shall be as manufactured by Mueller or Ford at the dimensions shown in the Details. All coppersetters shall be installed with a lockable angle ball valve assembly and outlet angle check valve on all size setters. Coppersetters shall be installed with flare fittings and all coppersetter assemblies shall be provided as shown in the Details with galvanized brace pipes for additional stability. All installations shall provide the coppersetter properly aligned with the meter box reader lid such that the meter is clearly visible below the reader lid. 8. Meter Boxes for 3/4-inch services: 3/4-inch meter boxes shall be light weight polymer concrete as shown in the Details. Meter boxes for 3/4-inch reclaimed water services shall provide a cover opening of 11 X 18 inches and boxes shall measure at least 18-inches in depth. Meter boxes and covers shall be rated for "heavy duty" uses, such as alleys, driveways, parking lots, etc. Standard meter box covers shall not bolt down to the box. The box interior walls and covers shall be consistently color - coded purple (Pantone 522 or similar). All covers shall include a 4 X 6 inch cast iron reader lid with the words "RECLAIMED WATER — DO NOT DRINK" cast into the lid in 1-1/2" tall lettering. The Town of Holly Springs reserves the right to require all meter box covers to include brackets and housing for "ITRON" compatible transponders for automated meter reading systems. All meter boxes and covers shall be installed as shown in the Details. 9. Meter boxes for 1-inch services: 1-inch meter boxes shall be lightweight polymer concrete as shown in the Details. Meter boxes for 1-inch reclaimed water services shall provide a cover opening of 11 X 18 inches and boxes shall measure at least 18-inch in depth. Meter boxes and covers shall be rated for "heavy duty" uses, such as alleys, driveways, parking lots, etc. Standard meter box covers shall not bolt down to the box. The box interior walls and covers shall be consistently color - coded purple (Pantone 522 or similar). All covers shall include a 4 X 6 inch cast iron reader lid with the words "RECLAIMED WATER — DO NOT DRINK" cast into the lid in 11/2" tall lettering. The Town of Holly Springs reserves the right to require all meter box covers to include brackets and housing for "ITRON" compatible transponders for automated meter reading systems. All meter boxes and covers shall be installed as shown in the Details. 10. Meter boxes for 1'/z and 2-inch services: 1 1/2" and 2" meter boxes shall be light weight polymer concrete as indicated in the Standard Details. All meter box interiors and covers shall be consistently color -coded purple (Pantone 522 or similar). Covers shall be marked on the top surface with a recognizable inscription indicating "RECLAIMED WATER — DO NOT DRINK" in 1-1/2" tall lettering. Piping for 1 1/2 and 2 inch reclaimed water meters shall be constructed from brass and copper tubing and shall be equipped with angled check valve outlets and by-pass flanged valve or by-pass flanged ball valve inlets. The box shall have an open bottom to allow drainage through stone. 2015 ED&CS 11-14 Supp # 9 Dec. 2023 11. Meter Vaults: Meter vaults and access doors within street right of way shall meet HS-20 loading requirements and shall be located outside of travel areas. The access double doors shall be aluminum with a flush drop lift handle, stainless steel hinges and bolts, a stainless steel slam lock, an automatic hold open arm, and compression springs to allow for easy opening. Covers shall be marked on the top surface with recognizable inscription indicating "Reclaimed Water -Do Not Drink" 12. Reclaimed Water Meters: Reclaimed water meters for 3/4" to 2" services will be provided by the Town of Holly Springs. Larger meters shall be provided by the developer as directed by the Executive Director of Utilities and Infrastructure Services. Reclaimed water meters, registers and covers shall be purple (Pantone 522 or similar). 11.04 RECLAIMED WATER IRRIGATION SYSTEMS A. GENERAL All reclaimed water irrigation systems within public street right of way require an encroachment agreement from the Town of Holly Springs or NCDOT prior to installation. Plans designating the location, size, material, and depth shall be submitted with the agreement application to the Engineering Department. Pipe material for the irrigation mainline proposed to be used within the public right of way shall be Schedule 40 PVC or greater. All pipe, fittings, and appurtenances shall be purple (Pantone 522 or similar). A minimum depth of 2 feet of cover shall be provided. A soil evaluation is necessary in order to determine the loading rate for irrigation permits. All development within the reclaim service area will need to complete an independent soil evaluation prior to submitting a reclaim irrigation permit. All reclaimed water irrigation systems are required to secure permits from the Code Enforcement Department and the Utilities and Infrastructure Services prior to installation and shall be inspected after installation. A separate meter is required for irrigation systems. For single family irrigation design, a CID, PE, or LA is required to develop the plan. For non -single family irrigation system designs, a PE must develop the plan. Impoundments for reclaimed water storage for large scale irrigation systems or aesthetic/decorative water features shall be designed in accordance with 15A NCAC 02U — Reclaimed Water. Service lines from mainline tap to the meter are installed and identified per the Town of Holly Spring's Standard Details. There shall be no direct cross -connection between potable and reclaimed water supplies. 2015 ED&CS 11-15 Supp # 9 Dec. 2023 B. DESIGNS Sprinklers chosen and located to maintain the following setbacks from the irrigation area to the following features: 1.) 25 feet from surface waters [perennial and intermittent streams, wetlands] not classified as tidal salt waters or high -quality water (SA). 2.) 100 feet from surface waters [perennial and intermittent streams, wetlands] classified as tidal salt waters or high -quality water (SA). 3.) 100 feet from any water supply well (not including monitoring wells). 4.) Sprinklers located on a steep slope have check valves installed on all the heads on that irrigation zone. 5.) No mainlines or valves shall be allowed within the utility/devil strip. Laterals will be allowed and shall be placed within 1 ft of sidewalk. 6.) The zoning of the irrigation system must allow that plants with different water requirements (such as grass and shrubs) are on separate zones. In addition, the irrigation design should consider the different microclimates found in most landscapes (such as north facing grass areas vs. south facing grass areas) and separate those microclimates into zones. These zoning practices may add slightly to the installation cost of an irrigation system, but can have a dramatic effect on system efficiency. 7.Guidelines on pressure at the head/emitter: Spray Heads 20 to 35 psi; gear rotors 60 psi or less; impact rotors 60 psi or less; drip emitters 40 psi or less. 8.Large commercial systems which have the potential to place undue burdens (demand or pressure requirements) on the Town of Holly Springs' public reclaimed distribution system must include on -site storage and/or pumping facilities. This determination will be made by the Executive Director of Utilities and Infrastructure Services. Design, operation, and maintenance of such on -site facilities shall be the sole responsibility of the applicant. These additional facilities must be designed in accordance with 15A NCAC 02U — Reclaimed Water. 9.Rain sensors must be installed to reduce the likelihood of overwatering. Rain sensors are required to remain in service at all times to prevent overwatering and/or ponding of reclaimed water. C. STREET CROSSING 2015 ED&CS 11-16 Supp # 9 Dec. 2023 All irrigation line street crossings shall be contained within a ductile iron or steel casing pipe. The Town of Holly Springs may, in some instances, permit irrigation systems installed in the medians of Town -maintained roadways. These systems must also have french drains installed behind the curb and gutter and piped to a storm drainage collection system. These systems shall be allowed only when some permanent mechanism is established for the private perpetual maintenance of the system(s). D. HOSE BIDS Hose bibs are not permitted for the reclaimed water system. E. RAIN SENSORS Rain sensors must be installed to reduce the likelihood of overwatering. Rain sensor must remain in operation to prevent ponding or runoff. 11.05 TESTING AND INSPECTION A. GENERAL 1. All reclaimed water used in testing and inspection must be disposed of properly as described in Section 11.00. 2. All materials must be approved by the Inspector prior to installation. Materials rejected by the Town of Holly Springs' Inspector shall be immediately removed from the job site. 3. Under no circumstance shall any waterline system valve be operated without prior approval by the Construction Inspector. Damage to Town of Holly Springs infrastructure resulting from illegal operation of valves shall be the responsibility of the Contractor. In addition, the Contractor shall be subject to a fine for operating a valve without prior approval. 4. The Contractor shall furnish all materials, labor, equipment, and shall pay for the water used to perform all testing and inspections to the satisfaction of the Construction Inspector. The Contractor shall obtain a Blowoff Permit from the Town of Holly Springs Engineering Department for use when blowing off reclaimed water mains. 5. Reclaimed water service taps shall not be made until after all main testing is completed, and bacteriological testing is satisfactory. B. TESTING 1. Hydrostatic Testing 2015 ED&CS 11-17 Supp # 9 Dec. 2023 a) All valves in the Town of Holly Springs reclaimed water system shall be operated by the Town of Holly Springs. A section of reclaimed water main which is to be hydrostatically tested shall be slowly filled with water at a rate which will allow complete evacuation of air from the line. Hand pumps shall not be used for the pressure testing of reclaimed water mains. Taps used for testing purposes shall be removed after testing. The corporation stops shall be removed and a threaded tapered plug shall be installed on the line. When approved by the Town of Holly Springs, the Contractor may utilize potable water or reclaimed water via an approved hydrant meter and RPZ assembly for testing and disinfection of new reclaimed mains which are not physically connected to a live reclaimed water supply. Once reclaimed water has been introduced into the system no direct connection to potable water will be allowed and an approved air gap assembly must be used. b) Any measured leakage not within the allowable limits as specified in the following table shall require repair of the reclaimed water main and additional testing until the standards are met. For pipe sizes other than those shown, the Contractor shall test within the allowable leakage amounts as specified by AWWA C600-99. All visible leaks shall be repaired regardless of the amount of leakage. Pipe Size (Inches) 4 6 8 12 16 20 24 2. Chlorination Allowable Leakage at 200-psi (Gal./Hr. per 1000 feet of pipe) 0.43 0.64 0.85 1.28 1.70 2.12 2.55 a) All additions or replacements to the reclaimed water system shall be chlorinated before being placed in service under the supervision of the Town of Holly Springs' Inspector in the following manner: i. Taps shall be made at the control valve at the upstream end of the reclaimed water main and at all extremities of the line including valves. ii. A solution of water containing 70% HTH available chlorine shall be introduced into the reclaimed water main by regulated pumping at the control -valve tap. The solution shall be of such a concentration that the reclaimed water main shall have a uniform concentration of 50 ppm total 2015 ED&CS 11-18 Supp # 9 Dec. 2023 3 chlorine immediately after chlorination. The chart below shows the required quantity of 70% HTH compound to be contained in solution in each 1,000 feet section of line to produce the desired concentration of 50 ppm. Pipe Size Pounds High Test Hypochlorite (70%) (inches) per 1000 feet of line 6 1.76 8 3.12 10 4.84 12 7.00 14 9.52 16 12.44 20 19.52 24 28.00 iii. The HTH Solution shall be circulated in the reclaimed water main by opening the control valve and systematically manipulating blowoffs and taps at the reclaimed water main extremities. All reclaimed water leaving the system during this test must be disposed of through either an approved use or sent to the sanitary sewer. The HTH solution must be pumped in at a constant rate for each discharge rate so a uniform concentration will be produced in reclaimed water mains. iv. HTH solution shall remain in reclaimed water mains for no less than 24 hours or as directed by the Town of Holly Springs' Inspector. v. Extreme care shall be exercised at all times to prevent the HTH solution from entering existing reclaimed water mains. Bacteriological Sampling a) Free residual chlorine after 24 hours shall be at least 10 ppm or the Town of Holly Springs' Inspector will require that the lines be re -chlorinated. b) Flushing of reclaimed water mains may proceed after 24 hours, provided the free residual chlorine analysis is satisfactory. Reclaimed water leaving the system because of line flushing must be returned to a sanitary sewer. Flushing shall be continued until an orthotolidine check (or other method approved by the Town of Holly Springs) shows that the reclaimed water mains contain only the normal chlorine residual. Samples for bacteriological analysis shall be collected by the Town of Holly Springs' Inspector 24 hours after flushing is completed. The Contractor shall furnish the sample bottles, the testing agency and such help as may be required to secure these samples. The Contractor shall also submit the test results to the Town of Holly Springs' Development Inspector. 2015 ED&CS 11-19 Supp # 9 Dec. 2023 c) If test results are unsatisfactory, the Contractor shall immediately rechlorinate reclaimed water mains and proceed with such measures as are necessary to properly sterilize those reclaimed water mains. d) The new reclaimed water system shall be valved off from the existing reclaimed water system until a satisfactory bacteriological sample has been obtained and the Town of Holly Springs' Inspector has authorized the use of the new reclaimed water system. C. INSPECTIONS Approved plans and permit must be issued and available on -site before any inspections are performed. 2. Underground Inspections — before work is covered up/back filled: a) Inspection of main line tap and piping to meter box; b) Inspection of underground piping from meter box through irrigation system from meter to end of system to insure compliance with approved plan and standards; 3. Final Inspection a) Includes inspection of the location of all heads, type of heads, spacing of heads and throw pattern of each head and correct pressure; b) Testing the system to ensure compliance with approved plans and Town of Holly Springs Ordinance; 4. A map of the approved valve and head layout shall be provided by the Contractor to the property owner and a copy placed near or with the timer. All zones shall be clearly labeled in the timer cabinet. 6. Responsible entity shall be listed on inner door of timer (for emergency contact purposes). 7. Verification of required setbacks (reclaimed water). D. CROSS CONNECTION CONTROL 1. Backflow prevention on potable water services serving any property that is also served with reclaimed water is required in accordance with the Federal Safe Drinking Water Act. At all locations where reclaimed water service is provided, the public potable water supply shall be protected by installation of an approved backflow prevention device. 2015 ED&CS 11-20 Supp # 9 Dec. 2023 a. For Residential Properties: prior to receiving reclaimed water service, a dual check valve shall be installed on each residential customer's potable water meter in order to protect the potable water system. A Reduced Pressure Principal (RPZ) type backflow prevention device downstream of the potable water meter is not required when the only reclaimed water use is landscape irrigation. b. For Multi -family complexes and commercial properties: master -metered potable water service and master -metered reclaimed water service shall be required to install a Reduced Pressure Principal (RPZ) type backflow prevention device downstream of the master potable water meter. 11.06 REPAIR OF RECLAIMED WATER SYSTEM Reclaimed water that leaves the system due to a leak or break in the system must be reported and handled as if it were a wastewater spill. A. Reclaimed Water Main Line Repairs 1. Joint leaks of Cast Iron Pipe, Ductile Iron Pipe, and PVC pipe shall be repaired by use of a bell joint leak repair clamp as manufactured by Rockwell, or other approved equal. 2. Line Breaks or Punctures shall be repaired by a full circle repair clamp as manufactured by Rockwell, Mueller, or other approved material. 3. Line Splits or Blow Outs shall be repaired by replacing the damaged section with ductile iron pipe with a cast iron coupling at each end. The following cast pipe couplings shall be used for each pipe material indicated: a) Ductile Iron Pipe - Rockwell 431 cast coupling or other approved equal. b) PVC Pipe — Rockwell 411 cast coupling or other approved equal. B. Reclaimed Water Service Line Repairs 1. A reclaimed water service line severed between the reclaimed water main and the reclaimed water meter shall be repaired using new type K copper tubing and bronze or brass 3-piece flared unions. 2. A corporation stop pulled out of a reclaimed PVC pipe water main shall have a new service saddle and a new corporation stop installed on the reclaimed water main. 3. A corporation stop pulled out of a ductile iron pipe shall have a full circle repair clamp placed over the old tap hole. A new tap shall be made and a new corporation stop installed on the reclaimed water main. 2015 ED&CS 11-21 Supp # 9 Dec. 2023 END OF SECTION 11.00 2015 ED&CS 11-22 Supp # 9 Dec. 2023