Loading...
HomeMy WebLinkAboutSW6240102_Plansheet - Proposed Conditions/Site Plan_20240507 ■ sl e N solutions SITE NOTES N F��S 00 F� 1. ALL ELEVATIONS SHOWN ARE IN REFERENCE TO THE p///,q 3/ pp civil engineering I land surveying BENCHMARK AND MUST BE VERIFIED BY THE GENERAL 9/& A2 409 Chicago Drive,Suite 112,Fayetteville,NC 28306 CONTRACTOR. 2p//J 9� A office 1910-426-6777 fax 1910-426-5777N license r4Dsite bee I ns com 2. EXISTING UNDERGROUND UTILITIES ARE SHOWN ONLY WHERE Fp 3 EVIDENCE COULD BE FOUND TO VERIFY LOCATION. PRIOR TO /- Q CONSTRUCTION OR EXCAVATION OF THE SITE, THE GENERAL QTY. TYPE PLANTING SIZE MIN. HEIGHT SCIENTIFIC NAME N I CONTRACTOR SHALL VERIFY ALL UTILITY COMPANIES TO CANOPY TREES VERIFY THE LOCATION OF THEIR RESPECTIVE UTILITIES. ALL I SITE * DAMAGE INCURRED TO EXISTING UTILITIES DURING 21 WILLOW OAK 2" CALIPER 8' QUERCUS PHELLOS CONSTRUCTION SHALL BE REPAIRED AT THE GENERAL CONTRACTOR'S EXPENSE. I CA1?q���j� 3. ASPHALT AND BASE TYPE SHALL BE PER THE DETAILS. Z ���Q���.•••"'•••. / ��j 6' ILEX OPACA A 4. HANDICAP RAMPS, SIGNAGE AND PARKING SPACES SHALL 6 AMERICAN HOLLY N/A �, � �� :OF Or�,•.�i BE PROVIDED BY THE CONTRACTOR AND INSTALLED PER o �0 " � :`� `9•L FEDERAL ADA AND LOCAL REQUIREMENTS. UNDERSTORY TREES • x < 5. ALL DIMENSIONS ARE TO THE BACK OF CURB OR TO THE Lj�/F 0o 02E4 ' �5 FACE OF SIDEWALK UNLESS OTHERWISE NOTED. 7 JAPANESE CHERRY 1.5" CALIPER 8' PRUNUS SERRULATA 1Q c tip � c~n cD cD 6. ALL RADII ARE 5' UNLESS OTHERWISE NOTED. s9 TiQ �/LJ I cD • .� z 7. PARKING STALLS MUST BE STRIPED WITH A 4 INCH SHRUBS A �S` FS °' •. G I NE .• N CONTRASTING STRIPE (YELLOW ON CONCRETE AND ASPHALT C T N N /�SCOTT••8����`` PARKING LOT). ® 79 NANDINA 2 GAL. 18" NANDINA DOMESTICA 2�6 N I-+ ��� z 8. HANDICAP PARKING SPACES ARE TO BE DESIGNATED BY m NORTH BLUE STRIPING AND EITHER A BLUE SYMBOL ON A WHITE I j o!5. v 6 24/ BACKGROUND OR A WHITE SYMBOL ON A BLUE 26 CARISSA HOLLY 2 GAL. 24" ILEX CORNUTA 'CARISSA' S I BACKGROUND. ALL HANDICAP PARKING STALLS REQUIRE i VICINITY MAP THE INSTALLATION OF THE PROPER SIGNAGE. /••� 9. ALL PARKING SPACES ARE TO BE LAID OUT IN ACCORDANCE WITH THE SITE PLAN DIMENSIONS.10. /� °o , REVISIONS ALL WASTE MATERIAL SHALL BE DISPOSED OF OFF-SITE IN N50°46'29"E 21.20' - NOT TO SCALE ACCORDANCE WITH STATE AND LOCAL LAWS AND / / FiQ N50°43'15"E 128.86' N50°50'34"E 29.96' G REGULATIONS. 11. ALL SITE IMPROVEMENTS SHALL BE INSTALLED PER CITY OF RAEFORD AND STATE REGULATIONS. 12. ALL EXISTING UTILITIES, FENCES, AND OTHER STRUCTURES i IMPEDING CONSTRUCTION SHALL BE REMOVED OR I RELOCATED. ® N 0 a C7 Z7 n rn V) o rn D o � INFILTRATION BASIN #1 z ®® w $ r^ v) J D Z D ::E Z Z c(D Z m rn ®® rn Z N ® O 0 rn LA m rn _ m 1 -4 m cn I LEGEND: z 35'R 1 0 ECM 00 ECM-EXISTING CONCRETE MONUMENT o Co EPKO EPK-EXISTING PK NAILCD EiR 0 EIR-EXISTING IRON ROD o O S49°09'23"W 50.52' 41 o _ ____ _ _ �, C Z a COMPUTED POINT I rr _ _ CD G I R/W - RIGHT OF WAY Cz _ --_�__- _ - _ _ �__ = r N/F - NOW OR FORMERLY _ SHARED ACCESS ­ EASEMENT-EASEMENT - n C _ _ __' __ - _ _ ___ _ -_-___ ____ PROJECT NAME PROPERTY LINE a _ -_ -- �- o o —OPT— — — OLD PROPERTY LINE ADJACENT PROPERTY LINE O o _ _ _ - _ - _ -_ - _- _ RIGHT-OF-WAY - -- - - SETBACK LINE Nog°09 23 E RAEFORD S I TF I 20'R 35'R � ss SANITARY SEWER LINE �� S J MAINTENANCE' ANCE $ � - X FENCE LINE G VASS ROAD 270 MAJOR CONTOUR 0 18'x24' (MIN.) CONCRETE e- _° -_' N z7s MINOR CONTOUR z ,I DUMPSTER PAD AREA FOR _ ' _ / I -P.0 LIGHT POLE co °' (2) STD. DUMPSTERS 125.1' CA DOLLAR PP• UTILITY POLE 6 p '' Z 41 C SANITARY SEWER MANHOLE - a- _ co _ ? o - / 20' o w / 42 �' o GENERAL O �'' 5' TURN DOWN 20 ® I SIDEWALK ® �/ m I Sid, co eG' 0 . B /�S' o / � N / _ �G / OPL— — —OPL— — —OPL— — O OPL— — —OPL— — —OPL— — - -OPL— — —OPL— — O p / > I I m co 0 0 c ® I� ® � $ w /z Cn Ln SITE & J I PROPOSED BUILDING / CO/ I ® o Ty0 rs (1 (76'x,40') / / / -X ,o,s4o SF �- m , ® N m LANDSCAPE SITE DATA Ln ' PLAN DEVELOPER RHETSON COMPANIES, INC J/�F�, MAILING ADRESS 2075 JUNIPER LAKE ROAD `3 I I / J IAlk I CITY, STATE WEST END, NORTH CAROLINA 27376 I / / tD CONCRETE WHEELSTOPS PIN NUMBER 694351301045 HC RAMP (TYP) 694351301044 I / I 1 694351301215 I /�2. . // / £ CLIENT 694351301216 $ — TOTAL LOT AREA 2.16 AC SHED 16.0' F/�Q O OPL— — �oP� �oP �I A BOLLARDS - - 4 RACK BICYCLE S I EXISTING ZONING AREA TO BE ELOPED HC16 AC I N49°15'35"E 19.95' • _ -�;_- PARKIN S RHETSON EXISTING USE RESIDENTIAL/VACANT PROPOSED USE RETAIL COMPANIES, INC. DISTURBED DENUDED AREA 1.9 AC SETBACKS REQUIRED: r✓- w /HE VY DU Y PAVEMENT I w %0� /y/�! / o SHOWN SHADED) `�9 / FRONT 40 _ / 45'R ® N `Q SIDE 10 z _ F / 41 q - - / P /, / I � REAR 15 �C�Q9 _ - - /f / 0 9 N S• 1 0 TFQ cc = _ _ w _-__ / w 2075 Juniper Lake Road PARKING: L- - V - I ^' �_ West End, North Carolina 27376 REQUIRED (INCLUDING HANDICAP) 31 _ _ _ :-_-=_ :_/ 40' MIN BLDG SETBACK m Phone: 910 944-0881 _ -20 R LIGHTED PYLON SIGN W PROPOSED (INCLUDING HANDICAP) 36 Co Co - = 24.4' ® Ap UNDERGROUND ELECTRICAL C PROPOSED HC SPACES 201 SHARED ACCESS_�(D - _ - f J cl EASEMENT -_----/-__--_-- -"--------- �/ /g® c"t \ =35'Rtk"e — 10' STREETSCAPE BUFFER _ � \ PROJECT INFORMATION a tiC 79 SSS �Sy FiQ /' 35'R !S.A ®® ®�/� DESIGNED BY: SCOTT p) o-- G���ti 29 /� � N55°11'24"E 64.83' TIE � - S53°21'24"W 89.50' _ N p//J�O 110 8 / / / 3 DRAWN BY: SCOTT STRIPED ISLAND TO BE NCDOT ROW DEDICATION N CHECKED BY: CHRIS 6' FROM WHITE LINE U N40°48'07"W 30.65' 0.43 AC PROJECT NUMBER: 2019 3 c� cp cp w US 401 (FAYETTEVILLE ROAD) c° N DRAWING SCALE 60' PUBLIC R/W N o LANDSCAPING NOTES: \ HORIZONTAL: 1"=30' 1. HEIGHT AND SPREAD OF TREE SPECIMEN SHALL MEET REQUIREMENTS > OF THE AMERICAN ASSOCIATION OF NURSERYMEN, AMERICAN STANDARD o FOR NURSERY STOCK. 2. SHRUBBERY IS TO BE PLANTED AT LEAST 30" FROM CURBING AND FROM END OF PARKING SPACES TO PREVENT DATE RELEASED DAMAGE FROM s 3. ANY CHANGES TOT HOE PROPOSED PLANT SCHEDULE MUST BE APPROVED BY THE DESIGNER OF RECORD AND THE \ \ �i �j� Ay'2 / / GRAPHIC SCALE o COUNTY. THERE ARE NO WETLANDS ON THE PROPERTY PER A REPORT PREPARED BY 0& 2 92 MAY 6, 2024 �` S(� J 30 0 15 30 60 120 *THIS LANDSCAPING PLAN IS THE MINIMUM REQUIRED TO MEET WITH THE RAEFORD LIDO. THE OWNER OR DEVELOPER IS JEFF HARBOUR, SPWS WITH TERRACON 2St2 `S6 ENCOURAGED TO CONSULT WITH A LANDSCAPE ARCHITECT IN ORDER TO DEVELOP A PLAN THAT IS MORE IN DEPTH N S6 THAN THE MINIMUM REQUIREMENTS. THIS PLAN IS FOR PERMITTING PURPOSES ONLY. SHEET NUMBER **OWNER SHALL CONFIRM THAT EACH PLANT LISTED IN THE CHART SATISFIES CHAPTER 9 OF THE LIDO PRIOR TO ( IN FEET ) PLANTING. ALL CHANGES SHALL BE APPROVED BY RAEFORD PLANNING DEPARTMENT. 1 inch = 30 ft. —200 0 N I N C Q O