HomeMy WebLinkAbout20151294 Ver 1_Approval Letter_20160119
Type of Impact Amount Approved Amount Approved
Temporary Impact Permanent Impact
Stream 60 linear ft. 290 linear ft.
Wetland 0 acre 0.22 acre
4. Diversion Ditches and other storm water conveyances as related to the sediment and
erosion control measures shall be matted and/or stabilized to reduce sediment loss and
turbidity. This includes interior/exterior slopes of sediment basins. 15A NCAC 02H .0506
(b)(3) and (c)(3)
5. Bare/fill slopes in excess of 15 feet in height and within 30 feet of surface waters shall be
matted. Strengthening of silt fence may be required along the boundary of the proposed
stormwater pond. 15A NCAC 02H .0506 (b)(3) and (c)(3)
6. The stormwater pond (Moody Lake) shall be maintained/repaired to meet the volume/size
requirements as previously approved under prior permits.
7. You are required to provide one copy of the approved SMP, including plan details on full-
sized plan sheets, with proof of approval. The approved SMP shall be submitted to the
DWR 401 & Buffer Permitting Unit (1650 Mail Service Center, Raleigh, NC 27699-1650)
before impacts
any authorized in this certification occur. After it is approved and
submitted to the Division, the SMP may not be modified without prior written
authorization. If the SMP is modified in the future, then you shall provide one modified
SMP with proof of approval to the DWR 401 & Buffer Permitting Unit prior to the
commencement of the modifications.
Stormwater discharge
8. structures at this site shall be constructed in a manner such that
the potential receiving streams (of the discharge) will not be impacted due to sediment
.
accumulations, scouring or erosion of the stream banks15A NCAC 02H .0506(b)(5)
9. Use of native vegetation and other soft stream bank stabilization techniques is
recommended where practicable instead of riprap or other bank hardening methods. If
riprap is necessary, it shall not be placed in the streambed, unless approved by DWR
10. During the construction of the project, no staging of equipment of any kind is permitted in
waters of the U.S., or protected riparian buffers. 15A NCAC 02H .0506(b)(3)
11. The Permittee shall ensure that the final design drawings adhere to the permit and to the
permit drawings submitted for approval. 15A NCAC 02H .0507 (c) and 15A NCAC 02H
.0506 (b)(2) and (c)(2)
12. All mechanized equipment operated near surface waters must be regularly inspected and
maintained to prevent contamination of stream waters from fuels, lubricants, hydraulic
fluids, or other toxic materials. 15A NCAC 02H.0506(b)(3)
13. No rock, sand or other materials shall be dredged from the stream channel except where
authorized by this Certification. 15A NCAC 02H.0506(b)(3)
14. The permittee shall report any violations of this Certification to the Division of Water