HomeMy WebLinkAboutWQCS00068_Renewal (Application)_20240503 ROY COOPER ,;
Governor 7
ELIZABETH S.BISER .•�„"° '
Serrc/u,l
RICHARD E.ROGERS,JR. NORTH CAROLINA
Director Environmental Quality
May 06, 2024
South Granville Water & Sewer Authority
Attn: Scott N. Schroyer, Executive Director
415 Central Ave Ste B
Butner, NC 27509
Subject: Permit Renewal
Application No. WQCS00068
South Granville Water and Sewer Authority (SGWASA)
Granville County
Dear Applicant:
The Water Quality Permitting Section acknowledges the May 3, 2024, receipt of your permit renewal application and
supporting documentation. Your application will be assigned to a permit writer within the Section's Non-discharge
permitting branch. Per G.S. 150E-3 your current permit does not expire until permit decision on the application is made.
Continuation of the current permit is contingent on timely and sufficient application for renewal of the current permit. The
permit writer will contact you if additional information is required to complete your permit renewal. Please respond in a
timely manner to requests for additional information necessary to allow a complete review of the application and renewal
of the permit.
Information regarding the status of your renewal application can be found online using the Department of Environmental
Quality's Environmental Application Tracker at:
https://www.deq.nc.gov/permits-rules/environmental-application-tracker
If you have any additional questions about the permit, please contact the primary reviewer of the application using the
links available within the Application Tracker.
Sincerely,
, --DocuSlgned by'.
Wren T edfo
AbffRgirgfi1ve Assistant
Water Quality Permitting Section
cc: Robert S. Jackson, Utility Superintendent
ec: WQPS Laserfiche File w/application
.DE Qs, North Carolina Department of lnvlrorwental Quaht) Division of Watt,Resources
Raleigh Regional Office 1800 Barrett Drive Raleigh North Carolina 27609
919 7914200
SGWASA
South Granville Water and Sewer Authority(SGWASA) is made up of four towns and two districts. We
have around 114 miles of gravity sewer, about 39 miles of force mains and 47 pump stations. It is
maintained by 12 staff members, doing weekly and annual maintenance as well as repairs 24/7 as needed.
At this time,we are in the mist of the 1-85 Project which will remove 6 pump stations and be building 3
new pump stations. It will consist of various size sewer pipes from 8"-36". This project will be
completed in 2028 and will handle the ever-growing need for the next 20+years.
Please find the following items:
• Cover Letter& Application for Renewal
• Section IV.3 Pump Station List
• Section IV.4 High Priority Lines List
• Section V.4 Annual Budget for Collection System(Updated and Approved)
• Section V.6 Capital Improvement Plan(Updated and Approved)
• Section VI.2 Response Action Plan
• Section VI.4 Contingency Plan RECEIVED
• Section V1.6 Comprehensive Collection System Map
If any other items needed, please reach out to us: MAY 0 3 2024
Scott N. Schroyer
Executive Director NCDEQ/DWR/NPDES
Office: (919)575-3367 Ext. 312
sschroverc sgwasa.org
Robert S.Jackson
Utility Superintendent
Office: (919)575-3112 Ext.2
Cell: (919)603-4109
rjacksonsqwasa.org
Or myself at:
Joel M. Coats
Project Manager
Office: (919)575-3367 Ext. 313
Cell: (919) 384-5517
jcoats@sgwasa.org
South Granville Water & 0 (919)575-3367 ® www.sgwasa.org Q 415 Central Ave, Ste B
Sewer Authority 0 (919)575-4547 0 customerservice@sgwasa.org Butner,NC 27509
I. APPLICANT INFORMATION:
1. Applicant's name(Municipality, Public Utility,etc): South Granville Water and Sewer Authority
2. Facility Information: Name: South Granville Water and Sewer Authority Collection System Permit No.:
WQCS0068 U.DgCbCC7 X Q 2
3. Applicant type: ® Municipal ❑ State ❑ Privately-Owned Public Utility
❑County ❑Other: RECEIVED
4. Signature authority's name: Scott N. Schroyer per 15A NCAC 02T.0106(b)
Title: Executive Director MAY 0 3 2024
5. Applicant's mailing address:415 Central Ave. Suite B
City: Butner State:NC Zip: 27509- NCDEQIDWR/NPDES
6. Applicant's contact information:
Phone number:(919)575-3367 Fax number: (_)_- Email address: sschroyer@sgwasa.org
IL CONTACT/CONSULTANT INFORMATION:
1. Contact Name:N/A
2. Title/Affiliation:
3. Contact's mailing address:
4. City: State: Zip:5. Contact's information:
Phone number: ( ) - Fax number:( )_- Email address:
IIII. GENERAL REQUIREMENTS:
I. New Permit or Premit Renewal? ❑New ® Renewal
2. County System is located in: Granville County
3. Owner&Name of Wastewater Treatment Facility(ies)receiving wastewater from this collection system:
Owner(s)&Name(s): South Granville Water and Sewer Authority
4. WWTF Permit Number(s): NC0026824
5. What is the wastewater type? 42%Domestic or 58%Industrial(See 15A NCAC 02T.0103(20))
Is there a Pretreatment Program in effect?® Yes or❑No
6. Wastewater flow: 1_6 MGD(Current average flow of wastewater generated by collection system)
7. Combined permitted flow of all treatment plants: 5_5 MGD
8. Explain how the wastewater flow was determined: ® 15A NCAC 02T.0114 or❑ Representative Data
9. Population served by the collection system: 20,000
IV. COLLECTION SYSTEM INFORMATION:
1. Line Lengths for Collection System:
Sewer Line Description Length
Gravity Sewer 114.2 (miles)
Force Main 39.6(miles)
Vacuum Sewer (miles)
Pressure Sewer (miles)
APPLICATION CSA 04-16 Page 3 of 5
2. Pump Stations for Collection System:
Pump Station Type Number
Simplex Pump Stations(Serving Single Building) 15
_Simplex Pump Stations(Serving Multiple Buildings) 0
, Duplex Pump Stations 47
3. Submit a list of all major(i.e.not simplex pump station serving a single family home)pump stations. Include the following
information:
➢ Pump Station Name
➢ Physical Location
➢ Alarm Type(i.e. audible,visual,telemetry, SCADA)
➢ Pump Reliability(Can convey peak hourly wastewater flow with largest single pump out of service)
➢ Reliability Source(permanent/portable generator,portable pumps)
➢ Capacity of Station(Pump Station Capacity in GPM)
4. Submit a list of all high priority lines according per 15A NCAC 02T .0402(2) known to exist in the collection system. Head
the list with"Attachment A for Condition V(4)"and include the system name.
➢ Use the same line identification regularly used by the applicant
➢ Indicate type of high priority line(i.e.aerial),material and general location
V. COLLECTION SYSTEM ADMINISTRATION:
1. Provide a brief description of the organizational structure that is responsible for management, operation and maintenance of
the collection system.
This systerm is made up of four towns and two districts. We have 114.2 miles of gravity sewer, 39.6 miles of force mains and 48
pump stations. It is maintained by 12 staff members,doing weekly and annual maintenance as well as repairs.
2. Indicate the current designated collection system operators for the collection system per 15A NCAC 08G.020I
Main ORC Name: Robert S.Jackson Certification Number: 1002398
Back-Up ORC Name: William B. Weaver Certification Number: 1013928
See the"WQCS Contacts and ORC Report"for a current listing of the ORC(s)the Division has on file for WQCS permit
3. Approximate annual budget for collection system only: $ 1,863,998.00
4. Submit a copy of your current annual budget.
5. Approximate capital improvement budge for the collection system only: $255,000
6. Submit a copy of your current capital improvement plan.
7. Is this collection system currently a satellite system ❑Yes or®No
8. Do any satellite systems discharge to this collection system ❑ Yes or®No(If yes complete table below)
Satellite System Contact Information(Name,Address, Phone Number)
Complete for Satellite Systems that have a flow or capacity greater than 200,000 GPD(Average daily flow)
9. List any agreements or ordinances currently in place to address flows from satellite systems:
N/A
APPLICATION CSA 04-16 Page 4 of 5
VI. COLLECTION SYSTEM COMPLIANCE:
1. Is a Response Action Plan currently in place®Yes or❑No
2. If Yes,submit a copy of the Response Action Plan or see table 6 below.
3. Is a pump station contingency plan currently in place?® Yes or❑No
4. If Yes,submit a copy of the pump station contingency plan or see table 6 below.
5. Is a comprehensive collection system map currently in place? ®Yes or❑No
6. Submit a submit a copy of the collection system map(CD or hardcopy)or indicate a schedule for completion
7. Thoroughly read and review the System-Wide Collection System Permit Conditions. Typically compliance schedules
are only offered to NEW permit applicants and NOT permit renewals. Any compliance dates must be included within
the permit prior to issuance or the permit holder will be found in violation upon inspection.
Current If no, Indicate a Typical
Permit Condition Compliance Compliance
Compliance? Date Schedule
I(4)—Grease ordinance with legal authority to inspect/enforce ®Yes ❑No 12— 18 mo.
1(5)— Grease inspection and enforcement program ®Yes ❑No 12— 18 mo.
I(6)—Three to five year current Capital Improvement Plan. ®Yes ❑No 12— 18 mo.
1(8)—Pump station contingency plan ® Yes ❑No 3 mo.
I(9)—Pump station identification signs. ® Yes ❑No 3 mo.
1(11)—Functional and conspicuous audible and visual alarms. ® Yes ❑No 3—6 mo.
II(5)—Spare pumps for any station where one pump cannot
handle peak flows alone(in a duplex station,the 2"d pump is ®Yes ❑No 6—9 mo.
the spare if pump reliability is met).
11(7)—Accessible rights-of-way and easements. ®Yes ❑No 6— 12 mo.
II(9)—Response action plan with Items 9(a—h). ®Yes ❑No 3 mo.
III(3)—Comprehensive collection system map ®Yes ❑No 10%per year
For conditions not listed,compliance dates are not typically offered. List any permit conditions that may be difficult for the
applicant to meet(attach clarification if needed):
VII. APPLICANT'S CERTIFICATION per 15A NCAC 02T.0106(b):
I, Scott N. Schroyer attest that this application for South Granville Water and Sewer Authority
(Signature Authority's Name&Title from Item I.4) (Facility name from Item 1.1)
has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this
application are not completed and that if all required supporting information and attachments are not included, this application
package will be returned to me as incomplete.
Note: In accordance with NC Gener tutes 3-215.6A and 143-215.6B, any person who knowingly makes any false statement,
representation, or certification in an appl atio hall be guilty of a Class 2 misdemeanor which may include a fine not to exceed
$10,000 as well as civil penalties up o$25,000 er violation.
Signature: Date: " V
APPLICATION CSA 04-16 Page 5 of 5
IV.3 SGWASA —
Audible,Visual, C
Pump Stations Street Address Pumps H.P GPM Telemetry&SCADA •
11TH ST. 201 11TH St Duplex 5 100 YES
B ST.#1 1511 West B st. Duplex 15 300 YES
B ST.#2 1917 West B St. Duplex 15 300 YES
Blackstone 1701 Will Suitt Rd. Duplex 7.5 170 YES
Brinkley Park 663 Cameron Dr. Duplex 4 50 YES
Butner Business Park 1079 Business Park Dr. Duplex 5 180 YES
Cedar Creek 1642 Saratoga Dr. Duplex 25 200 YES
Coley Park 620A Cedar Dr. Duplex 4 30 YES
Crossings at Butner 2091A Longwood Dr. Duplex 5 80 YES
Davenport 1621 Irving PI. Duplex 10 80 YES
Dutchville 1 1186A Breda Ln. Duplex 5 75 YES
Dutchville 2 653 Eindhoven Ln. Duplex 2 25 YES
E-Middleton Drive 1230 E. Middleton Dr. Duplex 15 180 YES
East Tally Ho 127 E. Tally Ho Rd. Duplex 7.5 90 YES
FOOD LION 1703 East D St. Duplex 15 230 YES
Franklin Street 120 Franklin St. Duplex 10& 15 50 YES
Gate 1 Road 1547 Gate 1 Rd. Duplex 25 225 YES
GCHS Pump Station 2043 Sanders Rd. Duplex 4 50 YES
Golden Pond 2791 Barry Ct. Duplex 10 50 YES
Granville Forest 102 Oak Rd. Duplex 25 180 YES
Granville Oaks 1620 NC Hwy 56/1569 Skipping Duplex 20 180 YES
Stone Ln.
Hunter Ridge 511 Wild Goose Ln. Duplex 5 126 YES
Joe Peed 1658 Joe Peed Rd. Duplex 125 700 YES
Joe Peed/Sewer Booster Station 1506 Joe Peed Rd. Duplex 125 700 YES
' Lake Rd. 1708 NC Hwy 56 Duplex 15 80 YES
Little School St. 204 School St. Duplex 3 25 YES
Lyons 1 1653 Will Suitt Rd. Duplex 5 57 YES
Lyons 2 1627 Will Suitt Rd. Duplex 15 192 YES
Ledge Creek 208 Old Hwy 75 S. Duplex 3 25 YES
Mangum Farms#1 3170 Old Hwy 75 S. Duplex 75 760 YES
Mangum Farms#2 103A Richmond Run Duplex 15 209 YES
Mt. Energy Lift Station 2640 NC Hwy 56 Duplex 5 75 YES
Montclair 1550.5 Montclair Ln. Duplex 2.5 15 YES
Mount Hope 105 West A St. Duplex 37 260 YES
Old 75 @ Ruritan Club 215 Old Hwy 75 N. Duplex 3 35 YES
Prestwick 213 Edinburgh St. Duplex 20 220 YES
Robertson Creek 2181 Brassfield Rd. Triplex 60 490 YES
Rogers Pointe 1621 Rogers Pointe Ln. Duplex 15 80 YES
Recovery Rd. 809 Recovery Rd. Duplex 2 25 YES
Southerby's 2582A Mint Julep Dr. Duplex 25 180 YES
Stem Main 101A School St. Duplex 36 300 YES
Stem Rd. 2116 Brogden Rd. Duplex 5 80 YES
Tar River Elementary 2642 Philo White Rd. Duplex 30 200 YES
Whitehall 439 Mayview Dr. Duplex 16 150 YES
Wilkins Road 1130 Wilkins Rd. Duplex 3.3 50 YES
Wilton School 3519 NC Hwy 56 Duplex 10 180 YES
Wynwood Acres 1510 Millstone Dr. Duplex 4 35 YES
IV.3
South Granville Water & Sewer Authority
Contingency Plan For Pump/Power Failure
If a pump fails at a pump station and cannot be fixed with parts on hand
and the station will not operate, the following steps should be taken:
1. Contract one or more of the following persons:
ORC:
Robert S.Jackson: C: (919) 603-4109/0: (919) 575-3112 Ext: 2/H: (252)432-5666
Backup ORC:
William B.Weaver: C: (919) 691-3719/0: (919) 575-3112 Ext: 3/H: (919)601-7141
Project Manager/Backup ORC:
Joel M. Coats: _C: (919) 384-5517/0: (919) 575-3367 Ext: 313/H: (252)432-3190
Any other operator:
Ray Harris/P.M: C: (984) 514-9407
Chad Ferguson/P.M: C: (984) 514-9365
Jacob Garner/P.M: C: (919)497-2219
Alex Marcinko/Operator CS-1: C: (984) 514-9404
David Rosario/Operator CS-1: C: (984) 514-9381
2. If pump Station needs to avoid a spill, call one of the following for pump and
haul services:
Curtin Septic Service: (919) 625-7745 or (919) 408-1335
Granville Farms: (919)603-4799
Vision: (919) 748-3760 or(919) 291-9540
3. SGWASA own a 6"& 8"Godwin Dri-Prime pump with 100'of 6"&600'of 8"pipe
to perform a by if needed. If more pipe is needed or another pump required call:
Godwin Pumps: (919) 661-6061 or 24hrs. (919) 795-9020
Sunbelt: (919) 208-5490
4. To initiate emergency pump repair/replacement, call one of the following:
Tencarva Machinery: 1 (800) 548-2764 or(843) 222-8680
Pete Duty: (919) 730-6525
Pearson Pumps: (919)734-4629 or(919) 580-5507
5. In case of power failure/phase problems call respective power company:
Butner/Wilton-Duke Power: 1 (800) 653-5307
Stem/Oxford-Duke Progress: 1 (866) 582-6345
Lyon Station/Cozart-Wake Electric: 1 (800)474-6300
Section IV.4
SGWASA High Priority Sewer Lines
Aerial:
1. MH 1836-1837 - 30" DIP North Outfall (between Veazey Rd and WWTP)
2. MH 1838-1839 - 30" DIP North Outfall (between Veazey Rd and WWTP)
3. MH 1873-1874 - 30" DIP North Outfall (between VeazeyRd. and Central Ave. Ext.)
4. MH 1894-1895 - 30" DIP North Outfall (between Central Ave. Ext. and East F St.)
5. MH 1900-1901 - 30" DIP North Outfall (between Central Ave. Ext. and East F St.)
6. MH 1755-1756 - 36" DIP South Outfall
7. MH 1738-1739 - 30" DIP South Outfall
8. MH 1739-1740 - 30" DIP South Outfall
9. MH 1741-1742 - 30" DIP South Outfall
10. MH 1747-1748 - 30" DIP South Outfall
11. MH 1935-1936 - 12" DIP South Outfall (West of 12th. St)
12. MH 1000-1001 - 20" DIP South Outfall (near Creedmoor Force Main Discharge)
13. MH 1209-1231 - 8" CIP (1300 Blk East D St.)
14. MH 1159-1922 - 18" CIP (900 BIk Between East D & East E St.)
15. MH 1926-1927 - 15"CIP (800 BIk East C St. Spooky's Outfall)
16. MH 1566-1567 - 8" PVC (300 BIk 22nd St.)
17. MH 1559-1560 - 8" CIP (300 BIk 21st St.)
18. MH 1940-1942 - 8" CIP (500 BIk 12th St.)
19. MH 1310 - 1998 - 18" CIP (1200 Blk East FSt.)
20. MH 1389 to dead end - 4" CIP (600 BIk East F St.)
21. MH 1469-1470 - 8" CIP (600 Blk 14th St.)
22. MH 1889-1890 - 8" CIP (C.A. Dillon Outfall by Veazey Rd. bridge)
23. MH 5741-5742 - 8" DIP (Lake Rogers bridge)
24. 4"DIP Force Main (Lake Rogers bridge)
25. MH 5600-5609 - 8" DIP (East of 15 near Fleming)
26. MH 5602-5606 - 8" DIP (off Wilson Way)
27. MH 5505-5820 - 8" DIP (off Corbin to Hwy 15)
28. MH 5757-5354 - 8" DIP (near Park Ave.)
29. MH 5382-5379 - 8" DIP (off Watson near outfall-2 sections)
30. MH 5410-5411 - 8" DIP (301 Watson St.)
31. MH 5779-5423 - 8" DIP (207 Cozart St.)
32. MH 5463-5471 - 8" DIP (back of Kristina Crossing)
33. cs v Force Main (I-85 bridge at Gate 2 Rd.)
34. MH 3379-3380 - 8" DIP (between E. Lyon Station and 1-85)
35. MH 3347-3348 - 12" DIP (by Murdoch)
36. MH 3185-3187 8" DIP (IVAC outfall)
Sewer Contacting Surface Water
38. MH 1684-1685 8" VCP (12th St. exposed in creek)
39. MH 1390-1391 10" VCP (23rd and F St. exposed in creek)
40. MH 1358-1391 8" VCP (F 24th and F St. exposed in creek)
41. MH 1587-1589 10" CIP (300 blk 24th. St.)
V. 4
kt E LID
MAY 0 3 2024
SGWASA NCDE
Q/DWR/NPDES
South Granville Water and Sewer Authority(SGWASA),North Carolina
Annual Budget Ordinance for Fiscal Year 2023-2024
BE IT ORDAINED by the Board Members of SGWASA,North Carolina
Section 1:
It is estimated that the following revenues will be available in the Water and Sewer Fund for the fiscal
period beginning July I,2023 and ending June 30,2024.
In comparison to the approved FY 22-23 Budget, the FY 23-24 water sales and sewer use charges were
estimated using a revenue increase of$400,000 for water,$650,000 for sewer,and S96,225 for capital.
REVENUES:
Water Revenues $5,700,000
Wastewater Revenues $8,800,000
Non-billing revenue $303,500
Interest Income $486,155
Other Financing Sources $0
Transfer from Fund Balance-Appropriate $0
Total revenues&other financing sources $15,289,655
The following amounts are hereby appropriated in the Water and Scwcr Enterprise Fund for the fiscal
period beginning July 1, 2023 and ending June 30,2024
EXPENDITURES: Dept:
Administration 7110 $766,305
Human Resources 7114 $137,308
Engineering 7118 $431,305
Billing/Collections 7120 $504,421
Raw Water 7130 $50,100
Water Treatment Plant 7133 $1,884,115
Wastewater Treatment 7145 $2,290,947
Utilities
Meter Reading 7136 $149,878
Water Line Maintenance 7139 S817,251
Sewer Line Maintenance 7140 $1,138,105
Pump Stations/Towers 8000 $725,893
Depreciation/Board/Other 7200 S2,545,992
Projects&Studies 7300 S50,000
Debt Service 7500 $3,798,035
Total Expenditures $15,289,655
Section 2:
The grand totals of estimated revenues and other financing sources and expenditures and other
financing uses for all funds for the fiscal period beginning July I,2023 and ending June 30,2024 are
shown below.
Grand Totals-MI Funds:
Revenues S15,289,655
Expenditures $15,289,655
Section 3:
The Executive Director shall have the authority to reallocate appropriations between line items,except
for salary and benefits,within a department up to a maximum of$10,000 Such re-appropriations must
be recorded like other re-appropriations and reported at a subsequent Board of Directors meeting after
the funds are moved.
All transfers must be in accordance with the North Carolina General Statutes The Executive Director
shall not have any authority to appropriate fund balance or to increase total appropriations
The Finance Director shall establish and maintain all financial records, which arc in accordance with
this Ordinance,and in accorda,cc with appropriate state statutes of the State of North Carolina
Upon introduction of the Ordinance by Board member 1?O 612:r WAY
and seconded by Board member _ LIN) JpRD
thts ordinance is adopted on this the Q th day of MAt_ 2023.
Ayes-
Nays 0
r
Jimmy oc Chair an
ATE
DQ
Krystle Lee,Sec tsry
V.6 FY 2023-2033 SGWASA CAPITAL IMPROVEMENT PROGRAM SUMMARY
Program Category Project 0 ct Project Description FY 2023.1024 FY 2026-2025 Cl 2025.2026 FY 2026.2027 FY 2017-2028 FY 2028-1029 FY 2029-2030 FY 2030-2031 FY 2031-2032 FY 2032-2033 10-Year Total
100-Raw Water Intake 101-01 SCAM upgrades to equipment flake Non a wesebroa6 ees.l $ 10.000
and Transmission
•
101-Water Treatment
Facility 101-01 Wier Treatment o ant va ation a Master PuM
1
n $ 00,000 $ 1A00
101-03 SCADAupgrades to 0A
Engineering e one Coast.MrRehab..Falwq clear
equipment $ 10,000 5 500 $ 60,000
101.02 Well $ 175,000 $ 175,000
101.05 Engineering Design for New Clear Well $ 250AM $ 250,000
101-06 Ne w Clear Well Constructor B CA•100 0 - $ - $ -
301.07 Engineering Design for PEAS Removal Process $ ---- 500,000 $ SM,OM
101-0e P2 ion 8 CA i $ _ $ - $ $ - $ -
A5 RemOvol Constru[f _
Creedrnoor
ster Pump Station
101-09 (Construction old ldmni m v.m.�
stratianl 5 225,000 $ - $ 225,000
_ ConcreteExterior e $ 50,000 $ 51,500 $ 101,500
101.10 16'Water Valve Replacement Project 100.000
- - E.Leon Station Road ACP Water Main Replac.m.nt Io.skn• -
102-Water Distribution .,102-01 consnvnioel $ 10.00 $ 700.000 $ a00.m0
Station R AMOO $ 100.0M $ MOAN $ 350.000
1oz-az W.Lyon u e cP weer Replacement
_ - 10303 rah Street Water Main Replacement $ 250.000 $ 40,000 $ 235,000 $ 525,000
102-04 Waterline Cleaning and Linn,Program $ 250,000 $ 257,500 $ 265,225 $ 213.10E $ - $ 098,513 $ $07,6f8 $ 316,692 $ 1,964,511
102.05 Mass Meter Replacement'purchase and a.rdl.a1 $ 1.000,000 _ $ 1,000,000
102-06 Mow Line Replacement Pan. 1 250,000 $ 257,500 $ 265,225 $ 273,182 $ - $ 290,510 $ 007,666 $ 316,692 $ 1,9n,S81
102.01 Hydrant Replacement Program $ 50,000 $ 50,000 $ 51,500 $ 53,045 $ 5e,036 $ 66,176 $ 5),961 $ 51703 $ 6690 $ 63,339 $ 557,955
102-08 valve Replacement Program $ 75.0 $ 77,250 $ - 79,568 $ 81,955 $ 84,410 $ 06,946 $ 09,554 $ 92,1a1 $ 95,0M $ 97,850 $ 859,791
103-Water Distribution
Purr.Sfatirant oevelopine Programs for GP.
Solar 10g-Water Towers Mixer Replacement program $ •
10e-01 Wilton Water Tower 1$35,0001 $ 35,000 $ 35.000
106_02 wilt SuM Road Water Tower 1535,0001 $ 35,000 $ 35.000
104-03 33rd Street Water Tower l$35,0001 $ 35,000 $ 35,000
104-04 6.Iltown Road Water Tower 1535,0001 $ 35,000 $ 35A00
10e-05 Sere ate,Tower(535,000) $ 35,000 $ 35,000
104-06 19e7 water Tower Replacement-0esi9n $ 150,000 $ 150,000
10.7 1.2 Water Tower placement-C Wdion $ -
105-Wastewater
Collection Sewer Rehab Program _ $
- 105-02 Sewer Project Area C-3 $ 160,000 $ 930,000 $ 030.1100 S 2.020,000
105-03 Sewer Project Mea Gil S 80,000 $ 860.000 $ 925,000
105-04 Sewer Promo area.10 $ 30.000 $ 150A00 f 170,000
10508 Sewer P,njmo Mu 0.-11 $ 150.000 $ 250,000
_ 105-09 Sewer Promo Mea 6-10 $ 230.000 $ 250,000
105.13 Sewer Project Mea Ml
410,000� 00 $lSa MnholeRMaAgom 67
95,00801, , ,
636
105-07 SMN 3204 Replacement l$15,0001FY23-20 Project $ -
105-05 S1411 3179 Replacement(515,000)FT23.24 Pr lect $ -
-
105-06 S N5720,5717 and 5707 Replacementp v2a-251 _ $ -
106-lift Stations&Force 1M 02 Lift station improvement Program'cleaning pump..other
_ Mains _ des) $ 75A00 $ n,150 $ 79,568 $ 21.955 3 KW $ g6,966 $ n,5. $ 92j61 $ MAIM $ MAN $ 059,793
- 02 Franklin Sweet III station Improvements-Engineering $ 2y0r
107-Wastewater
Treatment Facility 107-01 Digester el/02 Repairs $ 400AM $ 400,000
10)-02 Chemical Storage Tank Replacement - 5 -800,000 $ BM,M 00,00 O
107-0a Clarifier 10 Repair $ 000,080 $ 1,100,000 $ 1,20,000
107-05 SCADA upgrades $ 34500 $ WOO $ 82,500
10706 Exterior Sudac.s Cancel.0.$ab 6 Coating 5 50000 $ 51,500 $ 53,045 $ - $ 154,545
108-Admi0Wtra6On 107-01 Organbational-W0e Facility Needs Study S 50,000.00
Designated Fund Balance Carryover.$ 5,270,702 $ 3A67,202 $ 3,624,702 $ 3,199,522 $ 3,816,073 $ 4,194,610 $ 4.575A4 $ 0,033,370 $ 2,222,161 $ 2.0,717
Funded Depredation $ 2,070A00 $ 2,000A00 5 2,000.000 $ 2.0,000 $ 2.000,000 $ 2,000A0 $ 2.000AM $ 2,000,000 $ 2,000,000 $ 2A00A00
Total Designated Fund Balance Available$ 7,340,702 5 5,667,202 5 5,624,702 $ 5,399,522 $ 5,214,073 $ 6,186,610 $ 6,575,aa4 $ 5,003,372 $ 6,222,163 5 4,070,717
-
Emergency Project Funding Goal$ 250,000 $ 750,000 $ 250,000 $ 250,a0 $ 250,000 $ 250,000 $ 250,000 $ 250,000 $ 750,000 $ 250.000
AV.LIabk Cr0 project Funding$ 7,090,702 $ 5,417,202 $ 5,374,702 $ 5,149,522 $ 5,564,073 $ 5,944.610 $ 6,325,444 $ 5,133,371 $ 3,972,163 $ 4,620,717
Total Fiscal Year Projects$ 3,420,500 5 1,79;500 $ 1,975,100 $ 0,335,449 $ ;369,463 $ 1,369,167 $ 2,942,071 $ 2,911,210 $ 1,101,M6 $ 081.09 $ 19,112,425
Carryover Funding$ 3,667,202 $ 0,620,702 $ 3,399,52E $ 3,804,070 $ 4,1.1,610 $ 4,575,644 $ 0,383,372 $ 2,222,163 $ 2970,717 $ 3,726,277
Non-Designated CIP
funded Projects 105.01 2115 Protect(Hen-ARPA Funded) $ soo,Ooo $ 10,0M,000 $ 25,000,000 $ 35,50,000
TOTAL 10-YFA0 CIP PROJECT FUNDING$ 54Al2,415
9�n
VI.2
SGWASA Response Action Plan
This plan is in place if there is a problem in the wastewater collection system
that requires immediate action or response.
1. Contact Numbers
Robert S. Jackson, ORC Scott N. Schroyer, Executive Director
C: (919) 603-4109 C: (919) 939-4801
0: (919) 575-3112 Ext: 2 0: (919) 575-3367 Ext: 312
H: (252) 432-5666
William B. Weaver, Backup ORC DWQ-Raleigh Regional Office
C: (919) 691-3719 (919) 791-4200
0: (919) 575-3112 Ext: 3
H: (919) 601-7141
Joel M. Coats, Project Manager Emergency Management
C: (919) 384-5517 1 (800) 858-0368
0: (919) 575-3367 Ext: 313
H: (252) 432-3190
2. Response time (worst-case scenario) would be no more than 30min.
3. All spare pump parts are stored at warehouse at 320 West G St. Butner,
NC or at pump station. There are enough pump parts to fix most any
problem at all pump stations. If a part is needed that is not stored at
either of these locations, a vendor list is located on the ORC's Desk.
4. The utility crew has access to sewer cleaning equipment 24 hours a day,
7 days a week.
5. Access to engineers is always maintained.
6. Sources of emergency funds are available through our purchasing office
5 days a week and through verbal contact w/management. Parts can be
purchased on SGWASA funded credit card 24 hours a day, 7 days a
N
week.
7. Site-sanitation and clean-up materials are available to the utility crew
24 hours a day, 7 days a week. They are located at the warehouse.
8. Post-overflow/spill assessment is to be performed by the spill
coordinator (ORC and/or Backup ORC).
•
SPILL RESPONSE PLAN
A. Scope
The scope of this plan is intended to limit the environmental impact of any sanitary sewer
overflow (SSO). SSOs can endanger our environment and potentially the health of all persons
that come into contact with such events. Unchecked SSOs can result in significant penalties
from State and Federal environmental regulatory agencies as well. The protocols in this plan
are designed to protect our environment, citizens and employees from an SSO event.
B. Notification and Evaluation Protocol
The following protocol will be followed in the event of an SSO:
1. Upon initial notification of an SSO, an initial response will be made by the on-call person
if the SSO has been reported after hours. During working hours, a collection system
operator will respond. Upon arrival, this person will make an immediate assessment to
determine if an SSO event has taken place. If an event has taken place or is in progress,
this person will attempt to identify and possibly eliminate the source of the SSO. This
person will then contact the collection system ORC or back-up ORC and they will respond
without delay.
2. Once onsite, staff will conduct an assessment of the SSO and determine what is required
to mitigate the event and establish a course of action for remediation of the SSO site.
3. Once the SSO event has ceased, remediation procedures shall begin.
C. Remediation Protocols
Follow the protocol for the specific type of SSO site.
A. On Asphalt or Concrete
1. Set up containment at or near a storm drainage system; do not let the SSO enter the
storm drainage system.
2. Put up "CAUTION DO NOT ENTER" tape around the SSO site.
3. Spread lime and sand (or equivalent material) on spillage to a depth of 1 inch. Let
this stand for 1 hour and sweep up. If moisture or grease is still present, repeat
procedure.
-1. After removing the contaminated material, spread lime again to control odor, unless
inclement weather is threatening. If this is the case, do not apply lime.
3. If this spill goes into the storm drainage system, refer to creek procedure.
B In Creek or Stream
1. Look for floating solids and/or paper in creek in order to determine the proper
placement of dam. If possible, place the dam at least 50 feet below the last place
solids and/or paper was visible. The dam should be constructed near a manhole or a
point that is accessible to a vacuum truck. Build the dam using dirt that is capable
of handling creek and hydrant water without dam failure. Station two pumps at the
dam that are capable of handling creek flow. Use one pump for backup. Have
backhoe at site at all times with extra material so dam can rebuilt if a breach occurs.
Pump effluent from the creek behind the dam into the manhole or vacuum truck.
2. Put up "CAUTION DO NOT ENTER" tape from the SSO site to the dam site on both
sides of the creek in populated areas. In unpopulated areas restrict access where
there is any chance of humans coming in contact with the SSO.
3. Flush stream with water from a hydrant in sufficient quantities to remove waste from
the creek. Continue to pump and flush stream until all solids and/or paper is
removed. This process should continue until the ranking Utilities staff member is
satisfied that the stream is sufficiently cleaned.
4. If rip-rap is in creek, wash down with high pressure water until there is no waste
residue remaining on, or within the rip-rap structure.
5. If sludge is in creek, broom creek bottom and sides until there is no waste residue
remaining.
6. If creek flows into a body of water used for recreation, and or drinking, notify the
affected county and local officials as soon as the problem is discovered. If this
happens, refer to pond & lake protocols.
C. In Pond or Lake
1. Put up "CAUTION DO NOT ENTER" tape around the shoreline at the contaminated
area.
2. Clean area of all visible solids and paper products. Remove all visibly ponded
wastewater.
3. Contact the NC Division of Water Quality for further instructions on cleanup.
D. Outfall
1. Put up "CAUTION DO NOT ENTER" tape around the SSO site.
2. Clean area of all visible solids and paper products. Remove all visibly ponded
\vastewwater.
3. In open area, lime (powder) heavily and till. Repeat procedure. Seed and then put
down straw.
4. In an area where there is undergrowth or small trees, wash area with large amounts
of water. Push into creek towards pump site. Do this until no waste remains. Wait
for 12 to 24 hrs then lime the area heavily. Do not get lime in the creek. Do not
lime when the weather forecast is predicting rainza.u.
E. in Customer's Yard
1. Clean area of all visible solids and paper products. Remove all visibly ponded
wastewater.
2. Till the area whenever possible. Apply lime, seed and straw.
3. If not able to till, apply lime thoroughly.
i
II
VL4
South Granville Water & Sewer Authority
Contingency Plan For Pump/Power Failure
If a pump fails at a pump station and cannot be fixed with parts on hand
and the station will not operate, the following steps should be taken:
1. Contract one or more of the following persons:
ORC:
Robert S. Jackson: C: (919) 603-4109/0: (919) 575-3112 Ext: 2/H: (252) 432-5666
Backup ORC:
William B.Weaver_ C:_(91a) 691-3719/0: (919) 575-3112 Ext: 3/H: (919) 601-7141
Project Manager/Backup ORC:
Joel M. Coats: C: (919) 384-5517/0: (919) 575-3367 Ext: 313/H: (252)432-3190
Any other operator:
Ray Harris/P.M: C: (984) 514-9407
Chad Ferguson/P.M: C: (984)514-9365
Jacob Garner/P.M: C: (919)497-2219
Alex Marcinko/Operator CS-1: C: (984) 514-9404
David Rosario/Operator CS-1: C: (984) 514-9381
2. If pump Station needs to avoid a spill, call one of the following for pump and
haul services:
Currin Septic Service: (919) 625-7745 or(919)408-1335
Granville Farms: (919) 603-4799
Vision: (919) 748-3760 or(919) 291-9540
3. SGWASA own a 6"& 8"Godwin Dri-Prime pump with 100'of 6"&600'of 8"pipe
to perform a by if needed. If more pipe is needed or another pump required call:
Godwin Pumps: (919) 661-6061 or 24hrs. (919) 795-9020
Sunbelt: (919) 208-5490
4. To initiate emergency pump repair/replacement, call one of the following:
Tencarva Machinery: 1 (800) 548-2764 or(843) 222-8680
Pete Duty: (919) 730-6525
Pearson Pumps: (919)734-4629 or(919) 580-5507
5. In case of power failure/phase problems call respective power company:
Butner/Wilton-Duke Power: 1 (800)653-5307
Stem/Oxford-Duke Progress: 1 (866) 582-6345
Lyon Station/Cozart-Wake Electric: 1 (800)474-6300
SGWASA
A
Section VI.6 Comprehensive Collection System Map
Please see attach collection system maps:
And if more information is needed South Granville Water and Sewer Authority webpage have our GIS
available.
South Granville Water & 0 (919)575-3367 ®www.sgwasa.org 0 415 Central Ave, Ste B
Sewer Authority 0 (919)575-4547 0 customerservice@sgwasa.org Butner, NC 27509
441k,
Location: GSHS P/S- 2043
Sanders Rd. Stem, NC 27581
�
Station type: Duplex
GPM: 300
Alarm: Audible, Visual, Telemetry
- •- & SCADA
xs •
F
"
5..
.
Q
V .
u,
'• .:‘
'.I.'
-S• ?"..; „." ""*"..t.„;.....vc......:
/
L
.
Z
,
Ie 1;
r
T A
14141e1:411 /
•:o
IL
ev,
/ Location: East Tally Ho PIS- 127 E.
Tally Ho Rd., Stem, NC 27581
Station type: Duplex
GPM: 90
Alarm: Audible, Visual, Telemetry &
SCADA
s tiu
CA
A
\It-, ilit.L11 1 I I'I 1".....'
ac-
N
w
Isis\
\ .
\\ :. , ,
Location: Stem Main P/S-101A School St., 4-
Stem, NC 27581 [Location: Prestwick P/S-
Station type: Duplex 213 Edinburgh St., Stem, NC 27581
GPM: 300 Station type: Duplex
'Alarm: Audible, Visual, Telemetry & I GPM: 300
SCADA Alarm: Audible, Visual, Telemetry &
SCADA
cp
'tee
\ ,
J M
O
e-
S
Location: Old 75 P/S- 215 Old 75 "
North, Stem, NC 27581 ;
Station type: Duplex -_ `' —
GPM: 35 I-
Alarm: Audible, Visual, Telemetry & j
•
SCADA
i
Location: Little School P/S-204
School St., Stem, NC 27581
Station type: Duplex V„
.%
GPM: 25 �'
Alarm: Audible, Visual, Telemetry & •
' x Location: East Tally Ho P/S- 127
SCADA E. Tally Ho Rd., Stem, NC 27581
• Station type: Duplex
GPM: 90
Alarm: Audible, Visual, Telemetry
�, & SCADA
• S Location: Franklin Street P/S- 120
Franklin St. Stem, NC 27581
Station type: Duplex
GPM: 50
Alarm: Audible, Visual, Telemetry
& SCADA
•
Location: Stem Main P/S- 101A
School St. Stem, NC 27581
Station type: Duplex "� " " '
GPM: 300
Alarm: Audible, Visual, Telemetry
& SCADA Location: Ledge Creek P/S- 208
Old Hwy 75 S. Stem, NC 27581
Station type: Duplex
GPM: 25
Alarm: Audible, Visual, Telemetry
& SCADA
Location: Ledge Creek P/S- 208
Old Hwy 75 S. Stem, NC 27581
Station type: Duplex
GPM: 25
Alarm: Audible, Visual, Telemetry
& SCADA
Location: Mangum Farms #1 P/S-
3170 Old Hwy 75 S. Stem, NC
27581
Station type: Duplex
GPM: 760
Alarm: Audible, Visual, Telemetry &
SCADA A
N
•
AA 0
AAA
..w
„
Location: Mangum Farms #1 PIS-
3170 Old Hwy 75 S. Stem, NC
27581 ,116
Station type: Duplex
GPM: 760
•
Alarm: Audible, Visual, Telemetry &
SCADA
• Location: Mangum Farms #2 P/S- 103A
Richmond Run Stem, NC 27581
Station type: Duplex
ktg c!. GPM: 209
Alarm: Audible, Visual, Telemetry &
kr 4e,
SCADA
44,7„
*tv,”
•
Location: Old 75 Booster Station (Water)
,Station type: Duplex
Alarm: Audible, Visual, Telemetry &
SCADA
Location: Old 75 Booster Station (Water)
Station type: Duplex
11 Alarm: Audible, Visual, Telemetry &
SCADA
` 33rd St
Zx r.
a.
>.
c
ro
l
f'
of way'
�" JjJJJJ
N
II
Y�_
Vil
\\I 1001111
0 .
. ,.
, 1 \
, 14C ‘ • 1 ,
NS 12 ,
, .
..*
. .
li
1 .
...
-, •
41/4,•
N)0trfe°
d:',;. .,,.•k,
\ • ..
•
'.....'n a
.A
•• Ike. dillt.t*4111;14.4..10. .t
neetn Citiak 4
44\,
•
Location: SGWASA WWTP-1000
West H St. NC 27509
Max Capacity: 5.5M
•
Alarm: Audible, Visual, Telemetry
& SCADA
Location: Food Lion P/S- 1703
East D St. Butner, NC 27509
Station type: Duplex ->'
GPM: 230
Alarm: Audible, Visual, Telemetry
& SCADA
•
, \
‘ \
. ,'
yr
lit
191
•f 56 Str .a
4at . \
\ ,
5' F
•
,".41 - ,
Le....4dic.:,.ilr if)
.. ,\
30r ' IIP)IN'
0("aillL'"Illede.....41\. . \\c
, 'Of'\if\4)t.
_ ..„,..",.......,....
r„
.0,0,10::;,"")„,.......4.s..„.k.
u
\ .
... 1\94,40"4.
•
\ley"
sf
x,\\
/14,) ,,:f14:ifirctek\ \ ,
A.
,
tiA
fct
•
t \
k. . \ .
i, . . , \ ,.
, V ^00. ?5Cli ,I.
S. •
eloy. . /tie
4 ,.' 7 1 \
t \ \it ,
But r
\' Location: Wilkins Rd. P/S- 1130
1- Wilkins Rd. Butner, NC 27509
Station type: Duplex
GPM: 50
' 1;, Alarm: Audible, Visual, Telemetry
�. & SCADA
,
I, /
,,
/ ,. 0!
.
i;, o
' 1* *I
e
ii : t °'
Location: Cedar Creek P/S- 1642
Saratoga Dr. Creedmoor, NC
27522
Station type: Duplex
GPM: 200
Alarm: Audible, Visual, Telemetry
& SCADA
Location: B St. #2 P/S 1917
B St. Butner, NC 27509
Station type: Duplex
GPM: 300
Alarm: Audible, Visual, Telemetry
& SCADA .,
But* / / \T
if40., `1. \
*I o
///143116---4 . tf)e."‘ (\
3' t � 0
f \ 4
11 aC
t / i
41/40
w' \ .., /
f
Location: Mount Hope P/S- 105
West A St. Butner, NC 27509
i
/ IStation type: Duplex
Location: 11th St. P/S 201 11th 4\ ti
GPM: 260
St. Butner, NC 27509 4+ Alarm: Audible, Visual, Telemetry
Station type: Duplex & SCADA .
GPM: 100 �' _ i
Alarm: Audible, Visual, Telemetry ,+` Location: Butner Business Park
& SCADA P/S- 1079 Business Park Dr.
Butner, NC 27509
Station type: Duplex
ifGPM: 180
Alarm: Audible, Visual, Telemetry
& SCADA
0
/ .
y,,04:‘ , ,
1.
41. ' 4: , w ,
V 1 1\ ilf
tr
14siss\toredevo,
17
Location: 11th St. P/S- 201 11th -1
ISt. Butner, NC 27509
r' Station type: Duplex
i GPM: 100
Alarm: Audible, Visual, Telemetry
L& SCADA
"ol
(4
.
if
Location: B St. #1 P/S 1511 West
B St. Butner, NC 27509
Station type: Duplex
GPM: 300
Alarm: Audible, Visual, Telemetry
& SCADA
t
k
Location: Cedar Creek P/S- 1642
Saratoga Dr. Creedmoor, NC 27522 .
Location: B St. #2 P/S 1917 West
Station type: Duplex
B St. Butner, NC 27509 GPM:
Station type: Duplex Alarm: Audible, Visual, Telemetry & 4' -
GPM: 300 SCADA
J NIIIIlk
Alarm: Audible, Visual, Telemetry
& SCADA
Illik"
Location: Granville Forest P/S- 102 1
Oak Rd. Creedmoor, NC 27522
Station type: Duplex j
GPM: 180 �`
Alarm: Audible, Visual, Telemetry & „_
SCADA
jorm.„.,, .,
t.
, latillr:e.. Lim 1- 'tlit-30100‘:4.
r___.,„..r.s_
_ --, ' ---;-:.--„,i, ,
Coitr-t - -,
—ar Location: Coley Park P/S- 620A
Cedar Dr. Creedmoor, NC 27522
Eatleies
i\;.. ir,,,,,,_ , ,
Station type: Duplex
GPM: 30
Alarm: Audible, Visual, Telemetry
� � '& SCADA
I
\,\---4 - — _
Location: Montclair P/S- 1550.5
Montclair Ln. Creedmoor, NC 27522
Station type: Duplex
GPM: 15
Alarm: Audible, Visual, Telemetry &
Location: Gate 1 P/S- 1547 Gate 1 i" SCADA
Rd. Creedmoor, NC 27522
Station type: Duplex
GPM: 225 1r _
•,-,, Location: Wynwood Acres P/S-
Alarm: Audible, Visual, Telemetry 1510 Millstone Dr. Creedmoor,
& SCADA ,. " NC 27522
t <
Station type: Duplex
l+ GPM: 35
II
.tir •
4 `' Alarm: Audible, Visual, Telemetry
,: r& SCADA
' \._y
Location: Dutchville 1 P/S- 653
Endhoven Ln. Creedmoor, NC
v, 27522
Station type: Duplex
GPM: 25
Alarm: Audible, Visual, Telemetry& SCADA
14\
Location: Dutchville 1 P/S 1186A
_l --. — - [ redaLn. CreedmoorNC27522
Location: Brinkley Park P/S- 663
` Station type: Duplex
Cameron Dr. Creedmoor, NC GPM: 75
27522 ` Alarm: Audible, Visual, Telemetry
Station type: Duplex , ` & SCADA
GPM: 50
Alarm: Audible, Visual, Telemetry
& SCADA
1
co,441:0—
0/P‘LY\lisil 4 //".1
i .
Ly s
. .,,,...
•
. .
.,„, .
,
, .
/, ,,
,
56
Location: Rogers Pointe P/S-
. . .
1621 Rogers Pointe Ln.
Creedmoor, NC 27522
4, Station type: Duplex
. 0
V' -
GPM: 80
. *
Alarm: Audible, Visual, Telemetry
a-
4, & SCADA
I ,
el/
, 1
. ..
trioitti.ri Toeto r
. - .
V-3
14"
I 56
6 [Location: Granville Oak P/S- 1620 -, 1
'
44--•''' ' ' " , , .
. Hwy 56/1569 Skipping Stone Ln.
7
.
Creedmoor, NC 27522 • .
4 Station type: Duplex
, GPM: 180 .
I Alarm: Audible, Visual, Telemetry
S& CADA
..fka \
Butner j
\ Nsk
\ t 11
�l: =Location: Mount Hope P/S- 105
e
West A St. Butner, NC 27509
/ Station type: Duplex
GPM: 260
\ • :: , Alarm: Audible, Visual, Telemetr
y
.a
,: & SCADA
'> .
.a, Location: Crossing @ Butner P/S-
_ '' X , 2091A Longwood Dr. Creedmoor,
`�, NC 27522
,_ Station type: Duplex
'-...-• , :: ,, ' . ' x, ,,,.
. GPM: 80
F' Alarm: Audible, Visual, Telemetry &
SCADA
yi
)111? „, , _r
4141*
C.
y,
' Q. `v I�� ` 4
Location: Butner Business Park I
P/S- 1079 Business Park Dr. �`,°'
I *a...I.1111044,1
Butner, NC 27509
Station type: Duplex
11
GPM: 180 E , \ '9
'#Alarm: Audible, Visual, Telemetry
& SCADA 1 tk
1.,'•-0, I ., tt
9 \,
. '. . . .
0 1 . • „
a
VP'''
Location: Joe Peed B/S- 1506 Joe .../. • -4.
Peed Rd. Creedmoor, NC 27522 . / ..
Station type: Duplex .., ... 1
WI ,
GPM: 700 ti„,p,i ..
.. . '
Alarm: Audible, Visual, Telemetry \i'v \ .,. • • „ , ,_ ••• ,
_0 ..
' t .
• ,
4
0 kt e.
t ,
'.,t4i tri
, • . 1, ,, ,
N . ,t ,40.4.--iiillik' am : s
• k ,, ;.., „, .
,.
' , 1
i \'
Off •
/ G1,:r,. 44011414#111.10,LI'• „ ... , _
) . ,
\ .,. i
b , 1__
Location: East Middleton P/S-
'7:, ,
i
* *I'''.‘'' ,,,.1: 1 1 ' la'`.6 ' 4' . 1230 E. Middleton Dr. Creedmoor,
/ 0 ,, NC 27522
Station type: Duplex
i ',. :.-,:-
,.., .z.- GPM: 180
i ..-''
,•
,•:., Alarm: Audible, Visual, Telemetry
& SCADA
k 1 r V DI Ie
I . - / /
z...
.01
Location: Lyon 1 P/S 1653 Will Location: Blackstone P/S- 1701
Will Suitt Rd. Creedmoor, NC
27522
/ Station type: Duplex
GPM: 170
y,,,;,,, Alarm: Audible, Visual, Telemetry
& SCADA
e_vitiii( ,
0-
ir
zit
Suitt Rd. Creedmoor, NC 27522 =
Station type: Duplex
GPM: 57 ,% .r
Alarm: Audible, Visual, Telemetry f.
& SCADA
0 ,/,
I
Location: Lyon 2 P/S- 1627 Will
Suitt Rd. Creedmoor, NC 27522
Station type: Duplex
GPM: 192
Alarm: Audible, Visual, Telemetry
& SCADA
11
Location: Recovery Rd. P/S- 809
Location: Lake Rd. P/S- 1708 NC Hwy 56 Recovery Rd. Creedmoor, NC
Creedmoor, NC 27522 .27522
Station type: Duplex Station type: Duplex
GPM: 80
GPM: 25
Alarm: Audible, Visual, Telemetry & Alarm: Audible, Visual, Telemetry
SCADA & SCADA
NIN
•
•
Location: Joe Peed B/S- 1506 Joe
Peed Rd. Creedmoor, NC 27522
Station type: Duplex
GPM: 700
Alarm: Audible, Visual, Telemetry
& SCADA
Y �. 0
Peed Location:Rd. JoeCreedmoor Peed PIS-
NC 165827522 Joe
y
Station type: Duplex
ri ��' GPM: 700
` Alarm: Audible, Visual, Telemetry
r t. & SCADA "_ °+ `'
� y ,•
, .
fr
Location: East Middleton P/S- `.r ,,
1230 E. Middleton Dr. Creedmoor, ",
NC 27522 '°
Station type: Duplex
GPM: 180
Alarm: Audible, Visual, Telemetry
& SCADA
co
ci
r
Location: Davenport P/S- 1621
Irving PI. Creedmoor, NC 27522
Station type: Duplex
GPM: 80
Alarm: Audible, Visual, Telemetry
& SCADA y
Location: Stem Rd. P/S- 2116 s
Brogden Rd. Creedmoor, NC ,,
27522 •`
Station type: Duplex
GPM: 80
Alarm: Audible, Visual, Telemetry 40 le
& SCADA
Xk
fr
hi e."4,""11/4 1\
4 /
ci i /
a-
_,
t" *-'"
• rh
,�FiC#ti"9nwaytit
.� >'_ eeoo
1
t°
e
1
1, ,
re ,
& y
0
.gig
N
Location: Robertson Creek P/S-
50 Location: Hunter Ridge P/S 511 2181 Brassfield Rd. Creedmoor,
Wild Goose Ln. Creedmoor, NC NC 27522
27522 Station type: Triplex
Station type: Duplex GPM: 620
GPM: 126 Alarm: Audible, Visual, Telemetry
Alarm: Audible, Visual, Telemetry • & SCADA
& SCADA
i
Location: Southerby's P/S- 2582A
•
Mint Julep Dr. Creedmoor, NC ,- `-
27522 Mou al' ner9
:21(.'
Station type: Duplex
GPM: 180
Alarm: Audible, Visual, Telemetry -4 • IR'--
& SCADA .
w
Location: Mt. Energy P/S- 2640
- �'"` . , NC Hwy 56
��--- : d �` � Station type: Duplex
,. -
GPM: 75
' .._ , Alarm: Audible, Visual, Telemetry
. . . & SCADA
4
,
'4 s' ' . t
Location: Golden Pond P/S- 2791 .
Barry Ct. Creedmoor, NC 27522
Station type: Duplex
GPM: 50
Alarm: Audible, Visual, Telemetry
& SCADA
/
l '
'
`
| '~~
} �~
Location: Tar River FYS- 2642
� Phi|O White Rd. (�Peod0oOr, NCr, o/ � ' W
> 27522
Station type: Duplex
GPM: 200
) ` ' °\ /N8Un: Audible, Visual, To|ernetm'
& SCADA '
| Location: Wilton School P/S- 3o/�'�l
. �
NC Hwy 56 CreedmOOr, NC '
�
27522 �
-
| 818tiOO type: Duplex
' GPM: 180
Alarm: Audibl8, Visual, Telemetry '
& SCAOA -
| _ - U
i - -
^
. �
`
| l -
` u ,
/\
� -
| � �
| �
' �w
^'---' ' ^n
mcw/o«��vsa
Wilton