Loading...
HomeMy WebLinkAboutWQCSD0663_Compliance Evaluation Inspection_20240430DocuSign Envelope ID: 42C83496-93D7-4B03-828B-B44AC8333F49 Comoliance Insoection Resort Permit: WQCSD0663 Effective: 03/01/00 Expiration: Owner : Aqua North Carolina Inc SOC: Effective: Expiration: Facility: Bogue Watch Deemed Collection System County: Carteret Region: Wilmington Contact Person: Joel A Mingus Title: Coastal Area Manager Phone: 910-270-1412 Directions to Facility: System Classifications: Primary ORC: Raymond Lacy Braxton Certification: 1001598 Phone: 910-431-9248 Secondary ORC(s): On -Site Representative(s): On -site representative Joel A Mingus 910-270-1412 Related Permits: WQCS00367 Aqua North Carolina Inc - Cannonsgate Collection System Inspection Date: 04/30/2024 Entry Time 10:30AM Exit Time: 11:OOAM Primary Inspector: Helen I Perez Docusignetd�by: Phone: 910-796-7387 Secondary Inspectors): n DocuSigned by: E1 D645B4A39694BE... TOn.� �narrl OA. 5/1/2024 7F141E73B6F3456... Reason for Inspection: Routine Inspection Type: Collection System Inspect Non Sampling Permit Inspection Type: Deemed permitted collection system management and operation Facility Status: Compliant ❑ Not Compliant Question Areas: Miscellaneous Questions General Grease Control Inspections Lines Pump Stations (See attachment summary) Page 1 of 5 DocuSign Envelope ID: 42C83496-93D7-4B03-828B-B44AC8333F49 Permit: WQCSD0663 Owner - Facility: Aqua North Carolina Inc Inspection Date: 04/30/2024 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Inspection Summary: A routine compliance inspection of the Bogue Watch deemed collection system was conducted on April 30, 2024. The purpose of the evaluation was to verify that the facility is operating in compliance with the conditions and limitations specified in Permit WQCSD0663. Joel Mingus and Raymond Braxton, from Aqua North Carolina, were present during the inspection. This collection system serves the Bogue Watch Subdivision and the flow has been averaging 27,000 to 30,000 GPD. The system appears to be well maintained and operated. Wastewater from Pump Station (PS) #2 and #3 is pumped to PS #1. From there, it is pumped to the equalization (EQ) tank at the inactive Bogue Watch WWTF (WQ0029821) and then to Cannonsgate WWTF (W00028666), through a dedicated line, for treatment. Flow is monitored and recorded on the Cannonsgate's monthly NDMR. The EQ tank and high level alarms at the Bogue Watch WWTF were inspected on 9/13/2023 and found to be compliant. The facility is compliant with the deemed Collection System Permit WQCSD0663. Please review the comment sections of the inspection report for more details. Page 2 of 5 DocuSign Envelope ID: 42C83496-93D7-4B03-828B-B44AC8333F49 Permit: WQCSD0663 Owner - Facility: Aqua North Carolina Inc Inspection Date: 04/30/2024 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine General Yes No NA NE # Is this system a satellite system? ❑ ❑ ❑ # If Yes, what is system name or permit number? Is there a overall sewer system map? ❑ ❑ ❑ Does the map include: Pipe sizes ❑ ❑ ❑ Pipe materials (PVC, DIP, etc) ❑ ❑ ❑ Pipe location ❑ ❑ ❑ # Flow direction ❑ ❑ ❑ # Approximate pipe age ❑ ❑ ❑ # Pump station ID, location and capacity ❑ ❑ ❑ # Force main air release valve location & type ❑ ❑ ❑ # Location of satellite connections ❑ ❑ ❑ Are system maintenance records maintained? 0 ❑ ❑ ❑ Comment: A copy of the GIS map of the system was available for review. Grease Control Yes No NA NE Is grease/sewer education program documented with req'd customer distribution? ❑ ❑ ❑ # Are other types of education tools used like websites, booths, special meetings, etc? ❑ ❑ ❑ If Yes, what are they? (This can reduce mailing to annual.) Their website and through other social media. For public systems, is there a Grease Control Program via an ordinance/agreement? ❑ ❑ ❑ If Yes, does it require grease control devices at applicable locations? ❑ ❑ ❑ Is the Grease Control Program enforced via periodic inspections/records review? ❑ ❑ ❑ Is action taken against violators? ❑ ❑ 0 ❑ Comment: Aqua distributes grease education material to it's customers through bi-annual mailings along with information on their website and other social media. Inspections Yes No NA NE Are adequate maintenance records maintained? ❑ ❑ ❑ Are pump stations being inspected at the required frequency? ❑ ❑ ❑ Is at least one complete functionality test conducted weekly per pump station? ❑ ❑ ❑ Is there a system or plan in place to observe the entire system annually? ❑ ❑ ❑ Is the annual inspection documented? ❑ ❑ ❑ # Does the system have any high -priority lines/locations? ❑ ❑ ❑ Are inspections of HPL documented at least every 6 months? ❑ ❑ ❑ Are new lines being added to the HPL list when found or created? ❑ ❑ ❑ Page 3 of 5 DocuSign Envelope ID: 42C83496-93D7-4B03-828B-B44AC8333F49 Permit: WQCSD0663 Owner - Facility: Aqua North Carolina Inc Inspection Date: 04/30/2024 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Comment: The 3 pump stations are connected to a telemetry system and inspected weekly as required. Inspection lops were available for review and stored at each pump station. The paper lops are also maintained on tablets for electronic upload to their database for storage and review. Lines/Right-of-Ways/Aerial Lines Yes No NA NE Please list the Lines/Right of Ways/Aerial Lines Inspected: ROWs are located along the streets in the subdivision. Are right-of-ways and easements maintained for the full width for access? ❑ ❑ ❑ If No, give details on temporary access: Is maintenance documented? ❑ ❑ ❑ Were all areas/lines inspected free of issues? 0 ❑ ❑ ❑ Comment: 1723 feet of gravity sewer lines have been jetted this year. Pump Stations Yes No NA NE Please list the Pump Stations Inspected: PS #1- located at 501 Lanyard Drive PS #2- located between Bogue Watch Drive and Bogue Harbor Court PS #3- located at southern end of Fishermans Point # Number of duplex or larger pump stations in system 3 # Number of vacuum stations in system 0 # Number of simplex pump stations in system 0 # Number of simplex pump stations in system serving more than one building 0 How many pump/vacuum stations have: # A two-way "auto polling" communication system (SCADA) installed? 0 # A simple one-way telemetry/communication system (auto -dialer) installed? 3 For pump stations inspected: Are they secure with restricted access? ❑ ❑ ❑ Were they free of by-pass structures/pipes? ❑ ❑ ❑ Were wet wells free of excessive grease/debris? ❑ ❑ ❑ # Do they all have telemetry installed? ❑ ❑ ❑ Is the telemetry system functional? ❑ ❑ ❑ Is a 24-hour notification sign posted ? ❑ ❑ ❑ Does the sign include Owner Name? ❑ ❑ ❑ Pump station identifier? ❑ ❑ ❑ # Address? ❑ ❑ ❑ Instructions for notification? ❑ ❑ ❑ 24-hour emergency contact numbers? ❑ ❑ ❑ Are audio and visual alarms present? ❑ ❑ ❑ Are audio and visual alarms operable? ❑ ❑ ❑ Page 4 of 5 DocuSign Envelope ID: 42C83496-93D7-4B03-828B-B44AC8333F49 Permit: WQCSD0663 Owner - Facility: Aqua North Carolina Inc Inspection Date: 04/30/2024 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine # Is there a backup generator or bypass pump connected? 0 ❑ ❑ ❑ If tested during inspection, did it function properly? 0 ❑ ❑ ❑ Is the back-up system tested at least bi-annually under normal operating conditions? 0 ❑ ❑ ❑ # Does it have a dedicated connection for a portable generator? 0 ❑ ❑ ❑ # Is the owner relying on portable units in the event of a power outage? 0 ❑ ❑ ❑ # If Yes, is there a distribution plan? ❑ ❑ ❑ If Yes, what resources (Units/Staff/Vehicles/etc) are included in Plan? Portable units stored at the Cannonsgate WWTF. # Does Permittee have the approved percentage of replacement simplex pumps? ❑ ❑ 0 ❑ Is recordkeeping of pump station inspection and maintenance program adequate? 0 ❑ ❑ ❑ Do pump station logs include at a minimum Inside and outside cleaning and debris removal? 0 ❑ ❑ ❑ Inspecting and exercising all valves? 0 ❑ ❑ ❑ Inspecting and lubricating pumps and other equipment? 0 ❑ ❑ ❑ Inspecting alarms, telemetry and auxiliary equipment? 0 ❑ ❑ ❑ Comment: All 3 pump stations were secured with fencing/locks and had 24-hour notification signs posted. All visual and audible alarms were operable when high-level floats were pulled, and the telemetry system contacted operator by text and phone call. Pump Station #1 and #2 have back-up generators which are auto tested every week. Pump Station #3 has a dedication connection for a portable generator that is stored at the Connonsgate WWTF. Page 5 of 5