Loading...
HomeMy WebLinkAboutNCC241351_Site Plan or Location Map_20240502 \� VICINITY MAP / o \ \ LEGION / \ HRFD. d (CI\ �p� / �� \___ , E _______ _ ,„ SITE / W \ MATCH EXISTING PAVEMENT CSMB HOLDINGS,LLC r \"'° MATCH EXISTING PAVEMENT ----_2DBIPD 700 PG 493-00003078 "�ZONED HOD EXISTING ® \ \ \ \ Know what's below. 4 .75"EIR PROPERTY LUSH LINE ,,\ Call before you dig. .. \ \ CO • • Ir `ice •"-_...... ►.5.6,5933 E N .. \.... 4 O \",°\.. BEGIN CURB / 11 • I __ _ "►►►...... o l d1p0 I" p .� - / COVERED \„,_ &GUTTER BEFOREFORE STYOU OP l ' - ►►.. 21 / 1 4'1' ` VACUUM \ -d -a i I , __ �.".. • / I�,.2 _ / .. CANOPY m 0, 7 N• / �. i �/ �sy,,,_```. • \, CALL 1 800 632-4949 20 2 r "fi \ ,. \ME-CALL CENTE _ Fa`° I ,n _/ _�►� __ R1 ` °\,„, 'S THE I AW ci m l cc/ �I Y _ `4�75"59 I 066 E• 2TE i a'=m E [: / S7S SgE 39`p o- O O O I i m en Jbi n i I i' Ifimilummift h. lO ® .JODWALKPFL1\T . .. E _`® FLUSH WITH �` ` `` �.``' •-- PAVEMENT° ° ° ° �`a`S�•` .4 aill, / fE\H mil 1`�9 ,�' `` � p STORMWATER W� ;/ I' .' ^ •'. n �' f• " `v . `/Xn w I-4 U CONTROL w • MEASURE o / " frit ACCESSIB M r I r �� �Y �_ LE i ^ F C � O `�/ / i �� •`� V� �'d _ ° ° ��s' - /-PARKING / `� z Z CC ° 4. z �� 2�• h N —_*12 I �� I .75"EIR Q r O 1 ka �� -„. . ,, ,.,. , i, Z .° °� � PROPOSED SITE&MATERIALS LEGEND —_ ' �I , s / ~ CI I- 7 Z OA CONCRETE WALKWAY/SIDEWALK ti� _ ° \ -- ° - N / g •I 7„;:wl ,/ $ROLLOVER CURB / 'II` / ict •\ N O __ L SIDEWALK /D PAY STATION SEE SEPARATE ARCHITECTURAL PLANS I�I�IO ( ) _ _. ___—____ FLUSHfWITH !'�� ° g� O�YOOW OFE VACUUM BOOM(SEE SEPARATE ARCHITECTURAL PLANS) . .* PI,VEV QT 4,� ("�� ' — S / , O PROVIDE HANDICAP RAMP PER LOCAL,STATE AND FEDERAL ACCESSIBILITY PROPOSED 1"E/P _ L_� a i'REQUIREMENTS PROPERTY (` r^BOUNDARY ESCAPE iBG ` I/iSP \ \ "JOG VACUUM ENCLOSURE(SAME MATERIAL AS BUILDING) 46.56 ACRES LANE - o' v MGROSS TOTAL __ rr^^ /y� 1. `V OH DUMPSTER ENCLOSURE(WOOD ENCLOSURE;GATE TO BE SOLID OPAQUE) CSDB MB HOLDI PGS,LLC NZBi51', ; _ 6_BUFFER ygRO Pia �oh CI PID-00005186 "W __ / J ' 4 /t OI SITE LIGHT HCD-CZ ZONING UNDERCUOUND WATER I �l (MULTI-USE) RECLAMATION SYSTEM '- BICYCLE PARKING ` :rptRO!y,. ,, o 'I7�yL, ALL HMGE CONSTRUCTIONN TO BE IN ACCORDANCEATIONWITH ALL TOWN OF� O «, 15'B =�'t CARIHAGE STANDARDS AND SPECIFICATIONS 1.�d 13 PAINTED TRAFFIC ARROWrt 1.5"BG 7 } 2 //�� SIGHT TRIANGLE NOTE ' TRANSFORMER 1. ,..';.,/>lsl�, -,'. Ld TRAFFIC ARROW(SCHEMATIC AND NOT TO BE PAINTED.SHOWN ONLY TO I --------- DISPLAY E. , IIII WITHIN THE SIGHT TRIANGLES SHOWN ON THIS PLAN,NO DIRECTION OF TRAFFIC FLOW) OBSTRUCTION BETWEEN TWO(2)FEET AND EIGHT(8)FEET IN HEIGHT n ABOVE THE CURB LINE ELEVATION OR THE NEAREST TRAVELED WAY, - • 1''' ABOVE IF NO CURBING EXISTS. - RALPH& • SITE&MATERIALS NOTES MOLLIE COX PID-00001663 ALL CURB RADII ARE 5'UNLESS OTHERWISE NOTED PROPOSED PAVEMENT LEGEND: �i 0,—°,E OB 418 PG 847 • PRELIMINARY ZONED HCD DO NOT STANDARD-DUTY ASPHALT CONCRETE PAVEMENT 2 ALL CONCRETE WALKS ARE 6'WIDE(MEASURED FROM BACK OF CURB) ry USE FOR X 4"THICK CONCRETE UNLESS OTHERWISE NOTED CONCRETE SIDEWALK • CONSTRUCTION • PROPERTY LINE AND RIGHT-OF-WAY MONUMENTS SHALL NOT BE DISTURBED / PLAN STATUS 3 BY CONSTRUCTION. IF DISTURBED, THEY SHALL BE RESET TO THEIR ^ — ORIGINAL LOCATIONS AT THE CONTRACTOR'S EXPENSE BY A REGISTERED 0 • 3/15/24 PRELIMINARY SUBMITTAL— LAND SURVEYOR. PROPOSED PAVEMENT MARKING LEGEND i 4/7/24 1ST SUBMITTAL — 4 PROOF ROLL BUILDING AND ALL PARKING AREAS. NOTIFY OWNER OF ANY 0STOP SIGN(R1-1,30"X30") 0 UNACCEPTABLE AREAS. BUILDING DIMENSIONS SHOWN ON THE CIVIL ENGINEERING PLANS ARE FOR O HANDICAP SIGN WITH FINE(R7-8,18'x9') DATE DESCRIPTION 5 REFERENCE PURPOSES ONLY, CONTRACTOR SHALL USE THE ARCHITECTURAL VAN ACCESSIBLE HANDICAP SIGN WITH FINE(R7-8,18"x9'&R7-OD 12"x6") AND STRUCTURAL PLANS FOR EXACT BUILDING DIMENSIONS. O MEL KXO MEL ALL SIDEWALKS,CURB AND GUTTER,STREET PAVING,CURB CUTS,DRIVEWAY OD DO NOT ENTER SIGN(R5-1,30"x30") y DESIGN DRAWN CHKD— APPROACHES,HANDICAP RAMPS,ETC.CONSTRUCTED OUTSIDE THE I SCALE H'1 =20' 6 PROPERTY LINE IN THE RIGHT-OF-WAY SHALL CONFORM TO ALL MUNICIPAL SIGNING NOTES Vi — AND/OR STATE SPECIFICATIONS AND REQUIREMENTS. JOB No. 220205-01-001 1 NOTE THAT ALL SIGNS ARE TO BE MOUNTED ON GALVANIZED U-CHANNEL GRAPHIC, SCALE 7 ALL SITE DIMENSIONS AVE REFERENCED TO THE BACK OF CURB OR EDGE OF POSTS(3LB/FT).BOTTOM OF SIGN PANELS TO BE 7'ABOVE FINISHED GRADE. DATE MARCH 15,2024 PAYMENT UNLESS OTHERWISE NOTED. POSTS TO BE EMBEDDED AT LEAST 3'.EXCEPT HANDICAP PARKING SIGNS, 20 0 10 20 00 e0 — ALL DISTURBANCE INCURRED TO ANY ADJOINING PROPERTY DUE TO WHICH SHALL BE MOUNTED IN ACCORDANCE WITH THE DETAIL-SEE SHEET FILE No. 220205-01-001 8 CONSTRUCTION OR DEMOLITION SHALL BE RESTORED TO THE PREVIOUS C-7.0. CONDITION OR BETTER,AND TO THE SATISFACTION OF THE CITY OR STATE 2 THE CONTRACTOR IS RESPONSIBLE FOR INSTALLING ALL STOP SIGNS, AUTHORITY. DIRECTIONAL SIGNS,AND STRIPING SHOWN ON THE PLANS. ( IN FEET) C3.O 1 inch= 20 ft. SHEET VJ Cod fie name:V:\220205-Rhetsan Compmies Inc\220205-of-001(ENG)-Cape Ford Car Wash Carthage NC\Engineering\Engnes*Plms\Construction Documents\220205-01-001-SIT.drg