Loading...
HomeMy WebLinkAboutNC0082694_Permit Issuance_20150916Pat McCrory Governor NCDENR North Carolina Department of Environment and Natural Resources September 16, 2015 Mr. James M. Palenick, Interim Town Manager Town of Dallas 201 North Holland Street Dallas, NC 28034 Subject: Issuance of NPDES Permit NCO082694 Town of Dallas WTP Gaston County Dear Mr. Palenick: Donald van der Vaart Secretary Division personnel have reviewed and approved your application for renewal of the subject permit. Accordingly, we are forwarding the attached NPDES discharge permit. This permit is issued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between North Carolina and the U.S. Environmental Protection Agency dated October 15, 2007 (or as subsequently amended). This final permit contains no significant changes to its terms from those found in the draft permit sent to you on July 1, 2015. However, you are also reminded of the new condition requiring electronic reporting of discharge monitoring report (DMR) data using the Division's eDMR internet application. This new requirement will become effective on July 1, 2016 (approximately 270 days or nine months following the effective date of the permit). If any parts, measurement frequencies or sampling requirements contained in this permit are unacceptable to you, you have the right to an adjudicatory hearing upon written request within thirty (30) days following receipt of this letter. This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings (6714 Mail Service Center, Raleigh, North Carolina 27699-6714). Unless such demand is made, this decision shall be final and binding. Please note that this permit is not transferable except after notice to the Division. The Division may require modification or revocation and reissuance of the permit. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Water Resources or any other Federal, State, or Local governmental permits that may be required. 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Phone: 919-807-630011ntemet www.ncwaterqual4.org An Equal Opportunity 1 AffirnmWe Action Employer— Made in part by recycled paper Mr. James Palenick NC0082694 Permit Renewal 2015 p• 2 If you have any questions concerning this permit, please contact Bob Sledge at telephone number (919) 807-6398, or via e-mail at bob.sledge@ncdenr.gov. cer ly, Z�ZS. Jay Zimmerman, P. ., Director Division of Water Resources cc: Central Files Mooresville Regional Office/Water Quality NPDES File W Permit NCO082694 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER RESOURCES PERMIT TO DISCHARGE WASTEWATER UNDER THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, the Town of Dallas is hereby authorized to discharge wastewater from a facility located at the Dallas WTP 1342 Dallas Stanley Highway Northeast of Dallas Gaston County to receiving waters designated as the South Fork of the Catawba River in the Catawba River Basin in accordance with effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III and IV hereof. This permit shall become effective October 1, 2015. This permit and authorization to discharge shall expire at midnight on July 31, 2020. Signed this day September 16, 2015. Division of Water Resources By Authority of the Environmental Management Commission Page 1 of 7 Permit NCO082694 SUPPLEMENT TO PERMIT COVER SHEET All previous NPDES Permits issued to this facility, whether for operation or discharge, are hereby superseded and, as of this issuance, any previously issued permit describing this treatment facility or bearing this number is no longer effective. Therefore, the exclusive authority to operate and discharge from this facility arises under the permit conditions, requirements, terms, and provisions described herein. The Town of Dallas is hereby authorized to: 1. Continue to discharge filter backwash wastewater from a conventional water treatment plant (with surface water source water). This facility is located at the Dallas WTP, 1342 Dallas Stanley Highway, northeast of Dallas, in Gaston County. 2. Discharge from said treatment works at the location specified on the attached map into the South Fork of the Catawba River, classified WS-IV, CA waters in the Catawba River Basin. Page 2of7 Permit NCO082694 PART A. (1.) EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS [15A NCAC 02B .0400 et seq., 02B .0500 et seq.] During the period beginning on the effective date of this permit and lasting until expiration, the Permittee is authorized to discharge from outfall 001. Such discharges shall be limited and monitored) by the Permittee as specified below: EFFLUENT CHARACTERISTICS Parameter Code LIMITS MONITORING REQUIREMENTS Monthly Average Daily Maximum Measurement Frequency Sample T pype Sample Location Flow 50050 Monitor & Report (MGD) Weekly Instantaneous Effluent Total Suspended Solids C0530 30.0 mg/L 45.0 mg/L 21Month Grab Effluent pH 00400 >_ 6.0 and 5 9.0 standard units 21Month Grab Effluent Turbidity 00070 Monitor & Report (NTU) 21Month Grab Effluent Total Residual Chlorine2 50060 28 µg/L 21Month Grab Effluent Aluminum 01105 Monitor & Report (NgIL) Quarterly3 Grab Effluent Iron 01045 Monitor & Report (pg/L) Quarterly3 Grab Effluent Copper 01042 Monitor & Report (NgIL) Quarterly3 Grab Effluent Manganese 01055 Monitor & Report (NgIL) Quarterly3 Grab Effluent Fluoride 00951 Monitor & Report (Ng/L) Quarterly3 Grab Effluent Whole Effluent Toxicity Monitoring4 TGP3B Monitor & Report Quarterly Grab Effluent Footnotes: 1. No later than July 1, 2016 (270 days from the effective date of this permit), begin submitting discharge monitoring reports electronically using NC DWR's eDMR application system. See Condition A. (3.). 2. The Division shall consider all effluent TRC values reported below 50 µg/L to be in compliance with the permit. However, the Permittee shall continue to record and submit all values reported by a North Carolina certified laboratory (including field certified), even if these values fall below 50 µg/L. 3. Must be monitored in conjunction with the whole effluent toxicity test. 4. Chronic Toxicity (Ceriodaphnia dubia) P/F at 0.71 %: January, April, July and October. See Special Condition A. (2.). All samples must be collected from a typical discharge event. There shall be no discharge of floating solids or visible foam in other than trace amounts. Page 3 of 7 Permit NCO082694 A. (2.) CHRONIC TOXICITY MONITORING (QUARTERLY) [15A NCAC 02B .0500 et seq.] The permittee shall conduct quarterly chronic toxicity tests using test procedures outlined in the "North Carolina Ceriodaphnia Chronic Effluent Bioassay Procedure," Revised December 2010, or subsequent versions. The effluent concentration defined as treatment two in the procedure document is 0.71 %. The testing shall be performed as a Ceriodaphnia dubia 7-day pass/fail test. The tests will be performed during the months of January, April, July and October. These months signify the first month of each three month toxicity testing quarter assigned to the facility. Effluent sampling for this testing must be obtained during representative effluent discharge and shall be performed at the NPDES permitted final effluent discharge below all treatment processes. All toxicity testing results required as part of this permit condition will be entered on the Effluent Discharge Monitoring Form (MR-1) for the month in which it was performed, using the parameter code TGP3B. Additionally, DWR Form AT-1 (original) is to be sent to the following address: Attention: North Carolina Division of Water Resources Water Sciences Section/Aquatic Toxicology Branch 1621 Mail Service Center Raleigh, North Carolina 27699-1621 Completed Aquatic Toxicity Test Forms shall be filed with the Water Sciences Section no later than 30 days after the end of the reporting period for which the report is made. Test data shall be complete and accurate and include all supporting chemical/physical measurements performed in association with the toxicity tests, as well as all dose/response data. Total residual chlorine of the effluent toxicity sample must be measured and reported if chlorine is employed for disinfection of the waste stream. Should there be no discharge of flow from the facility during a month in which toxicity monitoring is required, the permittee will complete the information located at the top of the aquatic toxicity (AT) test form indicating the facility name, permit number, pipe number, county, and the month/year of the report with the notation of "No Flow" in the comment area of the form. The report shall be submitted to the Water Sciences Section at the address cited above. Should the permittee fail to monitor during a month in which toxicity monitoring is required, then monthly monitoring will begin immediately. Upon submission of a valid test, this monthly test requirement will revert to quarterly in the months specified above. Should any test data from this monitoring requirement or tests performed by the North Carolina Division of Water Resources indicate potential impacts to the receiving stream, this permit may be re- opened and modified to include alternate monitoring requirements or limits. NOTE: Failure to achieve test conditions as specified in the cited document, such as minimum control organism survival, minimum control organism reproduction, and appropriate environmental controls, shall constitute an invalid test and will require immediate follow-up testing to be completed no later than the last day of the month following the month of the initial monitoring. Page 4of7 Permit NCO082694 A. (3.) ELECTRONIC REPORTING OF DISCHARGE MONITORING REPORTS [G.S. 143-215.1(b)] Proposed federal regulations require electronic submittal of all discharge monitoring reports (DMRs) and specify that, if a state does not establish a system to receive such submittals, then permittees must submit DMRs electronically to the Environmental Protection Agency (EPA). The Division anticipates that these regulations will be adopted and is beginning implementation in late 2013. NOTE: This special condition supplements or supersedes the following sections within Part II of this permit (Standard Conditions for NPDES Permits): • Section B.'(11.) Signatory Requirements • Section D. (2.) Reporting • Section D. (6.) Records Retention • Section E. (5.) Monitoring Reports I. Reporting [Supersedes Section D. (2.) and Section E. (5.) (a)] Beginning no later than July 1, 2016 (270 days from the effective date of this permit), the permittee shall begin reporting discharge monitoring data electronically using the NC DWR's Electronic Discharge Monitoring Report (eDMR) internet application. Monitoring results obtained during the previous month(s) shall be summarized for each month and submitted electronically using eDMR. The eDMR system allows permitted facilities to enter monitoring data and submit DMRs electronically using the internet. Until such time that the state's eDMR application is compliant with EPA's Cross -Media Electronic Reporting Regulation (CROMERR), permittees will be required to submit all discharge monitoring data to the state electronically using eDMR and will be required to complete the eDMR submission by printing, signing, and submitting one signed original and a copy of the computer printed eDMR to the following address: NC DENR / DWR / Information Processing Unit ATTENTION: Central Files / eDMR 1617 Mail Service Center Raleigh, North Carolina 27699-1617 If a permittee is unable to use the eDMR system due to a demonstrated hardship or due to the facility being physically located in an area where less than 10 percent of the households have broadband access, then a temporary waiver from the NPDES electronic reporting requirements may be granted and discharge monitoring data maybe submitted on paper DMR forms (MR 1, 1.1, 2, 3) or alternative forms approved by the Director. Duplicate signed copies shall be submitted to the mailing address above. Requests for temporary waivers from the NPDES electronic reporting requirements must be submitted in writing to the Division for written approval at least sixty (60) days prior to the date the facility would be required under this permit to begin using eDMR. Temporary waivers shall be valid for twelve (12) months and shall thereupon expire. At such time, DMRs shall be submitted electronically to the Division unless the permittee re -applies for and is granted a new temporary waiver by the Division. Page 5 of 7 Permit NCO082694 A. (3.) ELECTRONIC REPORTING OF DISCHARGE MONITORING REPORTS, continued Information on eDMR and application for a temporary waiver from the NPDES electronic reporting requirements is found on the following web page: bt.tr)://vortal.ncdenr.ore/we"b/Wo/admin/boWi pu/edmr Regardless of the submission method, the first DMR is due on the last day of the month following the issuance of the permit or in the case of a new facility, on the last day of the month following the commencement of discharge. 2. Signatory Requirements [Supplements Section B. (11.) (b) and supersedes Section B. (11.) (d)1 All eDMRs submitted to the permit issuing authority shall be signed by a person described in Part II, Section B. (11.)(a) or by a duly authorized representative of that person as described in Part II, Section B. (11.)(b). A person, and not a position, must be delegated signatory authority for eDMR reporting purposes. For eDMR submissions, the person signing and submitting the DMR must obtain an eDMR user account and login credentials to access the eDMR system. For more information on North Carolina's eDMR system, registering for eDMR and obtaining an eDMR user account, please visit the following web page: http://portal.ncdenr.org/web/wq/admin/bog/ipu/edmr Certification. Any person submitting an electronic DMR using the state's eDMR system shall make the following certification [40 CFR 122.22]. NO OTHER STATEMENTS OF CERTIFICATION WILL BE ACCEPTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. " 3. Records Retention [Supplements Section D. (6.)l The permittee shall retain records of all Discharge Monitoring Reports, including eDMR submissions. These records or copies shall be maintained for a period of at least 3 years from the date of the report. This period may be extended by request of the Director at any time [40 CFR 122.41]. Page 6 of 7 PP�;r rrrrnna')Aon II!' �I 'm t ty/7�l.. ..A 71 10-Q��I�l t 7 15 „ n ;�= �, ;, ,.� 11 % �� u��1� �4;qq � � ' G l P Tw i � c[sx �`. �{ I t I ! . ,\ t4 Clem Y � K V � A `.4 10• � r. Nti �. �� � I � • •'� I�c J I f _`y c`1� J I 11 � 'p 9 ,/_ J � I�!/0 ea AX Town of Dallas Facility Dallas WTP Location La Hue 35' 19' 48" N State Grid: Gastonia NoM Loneitnde: 81- 09' 58" W Permitted Flow- N/A not m scale T AOrth NPDES Permit NCO082694 Gaston County RecOAne Stream South Fork Catawba River Stream Cl.,,- WS-IV CA Dninaee B.,,W Catawba River Basin Sulr-Basin 03 08-35 Page 7 of 7 NCDENR North Carolina Department of Environment and Natural Resources Pat McCrory Governor June 30, 2015 MEMORANDUM To: Keri B. Cantrell, Ph.D, P.E. NC DENR / DWR / PWS Environmental Engineer Mooresville Regional Office From: Bob Sledge IV Compliance & Expedited Permitting Unit Subject: Review of Draft NPDES Permit NCO082694 Town of Dallas WTP Gaston County Donald R. van der Vaart Secretary Please indicate below your agency's position or viewpoint on the draft permit and return this form by July 30, 2015. If you have any questions on the draft permit, please contact me at (919) 807-6398 or via e-mail at bob.sledge@ncdenr.gov. RESPONSE: (Check one) F] Concur with the issuance of this permit provided the facility is operated and maintained properly, the stated effluent limits are met prior to discharge, and the discharge does not contravene the designated water quality standards. F] Concurs with issuance of the above permit, provided the following conditions are met: F� Opposes the issuance of the above permit, based on reasons stated below, or attached: Signed Date:7/13/2015 1617 Mail Service Center, Raleigh, {forth Carolina 27699-1617 Phone: 919-807-6300 Untemet: www.ncwaterqua[4.org An Equal Opportunity 1 Affirmative Action Employer— Made in part by recycled paper PUBLIC NOTICE North Carolina Environmental Management Commission/ NPDES Unit 1617 Mail Service Center Raleigh, NC 27699-1617 Notice of Intent to Issue a NPDES Wastewater Permit The North Carolina Envi- ronmental Management Commission proposes to issue a NPDES waste- water discharge permit to below. Written comments regard- ing the proposed permit will be accepted until 30 days after the publish date of this notice. The Director of the NC Division of Water Resources (DWR) may hold a public hearing should there be a sTruft- 2 t agree of public inter- est Please mail comments and/or information re- quests to DWR at the above address. Interested persons may visit the DWR at 512 N. Salisbury Street, Raleigh, NC to review in- formation on file. Addi- tional Information on NPDES permits and this notice may be found on our website: htto://oortal. esMalaritlar 0r My ca4 ing (919) 807-6304. The Town of Dallas has re- quested renewal of permit N00082694 for the Dallas WTP in Gaston County; this permitted discharge is filter backwash wastewater to the South Fork Catawba River in the Catawba River Basin. 1 C-July 3, 2015. Text GS565151 to 56654 AFFIDAVIT OF INSERTION OF ADVERTISMENT The Gaston Gazette Gastonia, N.C. Gaston County The Gaston Gazette does certify that the advertisement for: PUBLIC NOTICE North Carolina Environmental Management Commission/ NPDES Unit 1617 Mail Service Measuring 7.35 inches appeared in The Gaston Gazette, a newspaper published in Gaston County, Gastonia, N.C., in issue(s): 07/03/2015. Name of Account: NCDENR/DWQ/NPDES Order Number: 54565151 Ad Number: 54666769 Sworn to, and subscribed before me this 10 th day of July, 2015. Via Nor p Lisa . yble, Notary Public IMLIC My Commission Expires April 25, 2017 FACT SHEET FOR EXPEDITED PERMIT RENEWALS This form must be completed by Permit Writers for all expedited permits which do not require full Fact Sheets. Expedited permits are generally simple 100% domestics (e.g., schools, mobile home parks, etc) that can be administratively renewed with minor changes, but can include facilities with more complex issues (Special Conditions, 303(d) listed water, toxicity testing, instream monitoring, compliance concerns). Basic Information for Expedited Permit Renewals Permit Writer/Date Bob Sledge 6/29/2015 Permit Number NCO082694 Facility Name Town of Dallas WTP Basin Name/Sub-basin number Catawba 03-08-35 Receiving Stream South Fork Catawba River Stream Classification in Permit WS-IV CA Does permit need Daily Max NH3 limits? No Does permit need TRC limits/language? Already Included Does permit have toxicity testing? Yes* Does permit have Special Conditions? Added eDMR Condition Does permit have instream monitoring? No Is the stream impaired on 303 d list)? No Any obvious compliance concerns? Tox??? Otherwise, no Any permit mods since lastpermit? No Current expiration date July 31, 2015 New expiration date July 31, 2020 Comments received on Draft Permit? No * For unknown reasons, at the last renewal the tox test concentration was set at 90%. The discharge is to a free flowing portion of the river, not affected by impoundments. New calculations were done, establishing the IWC at 0.71 %. IWC Calculations Town of Dallas WTP NCO082694 Prepared By: Bob Sledge, NPDES Unit Enter Design Flow (MGD): 05 Enter s7Q10(cfs): -.09 Enter w7Q10 (cfs): Residual Chlorine Ammonia (NH3 as N) (summer) 7Q10 (CFS) 109 7Q10 (CFS) 109 DESIGN FLOW (MGD) 0.5 DESIGN FLOW (MGD) 0.5 DESIGN FLOW (CFS) 0.775 DESIGN FLOW (CFS) 0.775 STREAM STD (UG/L) 17.0 STREAM STD (MG/L) 1.0 UPS BACKGROUND LEVEL (l 0 UPS BACKGROUND LEVEL 0.22 IWC (%) 0.71 IWC (%) 0.71 Allowable Conc. (ugll) 2408 Allowable Conc. (mg/1) 110.7 Ammonia (NH3 as N) (winter) 7Q10 (CFS) 199 Fecal Limit 200/100ml DESIGN FLOW (MGD) 0.5 (If DF >331; Monitor) DESIGN FLOW (CFS) 0.775 (If DF <331; Limit) STREAM STD (MG/L) 1.8 Dilution Factor (DF) 141.65 UPS BACKGROUND LEVEL 0.22 IWC (%) 0.39 Allowable Conc. (mg/1) 407.5 INPDES Servor/Current Versions/IWC 6/3/2015 NPDES PERMIT APPLICATION - SHORT FORM C - WTP For discharges associated with water treatment plants Mail the complete application to: N. C. Department of Environment and Natural Resources Division of Water Quality / NPDES Unit 1617 Mail Service Center, Raleigh, NC 27699-1617 NPDES Permit Number INCOO 82694 If you are completing this form in computer use the TAB key or the up - down arrows to move from one field to the next. To check the boxes, click your mouse on top of the box. Otherwise, please print or type. I. Contact Information: Owner Name TOWN OF DALLAS Facility Name TOWN OF DALLAS WATER TREATMENT PLANT Mailing Address 210 N. HOLLAND STREET city DALLAS RKEIVEDIDENWDWR State / Zip Code NORTH CAROLINA 28034 Telephone Number (704 ) 922-1309 MAy 2 1 2015 Fax Number ( 704 ) 922-9519 Water Quality e-mail Address mhurt@dallasnc.net Permitting Section 2. Location of facility producing discharge: Check here if same as above ❑ Street Address or State Road 1342 DALLAS STANLEY HWY. City DALLAS State / Zip Code NC 28034 County GASTON 3. Operator Information: Name of the firm, consultant or other entity that operates the facility. (Note that this is not referring to the Operator in Responsible Charge or ORC) Name Mailing Address City State / Zip Code Telephone Number ( ) Fax Number { ) 4. Ownership Status: Federal ❑ State ❑ Private ❑ Public Page I of 3 Version 5/2012 NPDES PERMIT APPLICATION - SHORT FORM C - WTP For discharges associated with water treatment plants S. Type of treatment plant: © Conventional (Includes coagulation, flocculation, and sedimentation, usually followed by filtration and disinfection) ❑ Ion Exchange (Sodium Cycle Cationic ion exchange) ❑ Green Sand Filter (No sodium recharge) ❑ Membrane Technology (RO, nanofiltration) Check here if the treatment process also uses a water softener ❑ 6. Description of source water(s) (i.e. groundwater, surface water) South Fork of The Catawba River 7. Describe the treatment process(es) for the raw water: The river water is pumped to a pee settling basin where copper sulfate is added for algea S. Describe the wastewater and the treatment process(es) for wastewater generated by the facility: The waste water from the treatment plant is Alum 9. Number of separate discharge points: Outfall Identification nu=ber(s) 1 10. Frequency of discharge: Continuous ❑ Intermittent x❑ If intermittent: Days per week discharge occurs: 7 days Duration: 120 minutes 11. Plant design potable flowrate 1.0 MGD Backwash or reject flow MGD 12. Name of receiving stream(s) (Provide a map showing the exact location of each outfalI, including latitude and longitudes South Fork of the Catawba River 13. Please list all water treatment additives, including cleaning chemicals or disinfection treatments, that have the potential to be discharged. Alum / aluminum sulfate es No Page 2 of 3 Version 5/2012 NPDES PERMIT APPLICATION - SHORT FORM C - WTP For discharges associated with water treatment plants Iron sulfate / ferrous sulfate Yes No Fluoride Yes No Ammonia nitrogen / Chloramines Yes No Zinc -orthophosphate or Sweetwater CP1236 TeelNo List any other additives below: Total chlorine residual, Aluminum, Iron, Total suspended solids 14. Is this facility located on Indian country? (check one) Yes ❑ No B 15. Additional Information: D Provide a schematic of flow through the facility, include flow volumes at all points in the water treatment process. The plan should show the point[s] of addition for chemicals and all discharges routed to an outfall [including stormwater]. D Solids Handling Plan 16. NEW Applicants Information needed in addition to items I -I S.- New applicants are highly encouraged to contact a permit coordinator with the NCDENR Customer Service Center. Was the Customer Service Center contacted? ❑ Yes ❑ No v Analyses of source water collected D Engineering Alternative Analysis Discharges from Ion Exchange and Reverse Osmosis plants shall be evaluated using a water quality model. 17. Applicant Certification I certify that I am familiar with the information contained in the application and that to the best of my knowledge and belief such information is true, complete, and accurate. VA.W 'do�e-'O=&SL14 ew - AaAbo' name of Person Signing Title As •l7- rS Signature of Applicant Date Forth Carolina General Statute 143-215.6 (b)(2) provides that: Any person who knowingly makes any false statement representation, or certification in any application, record, report, plan, or other document files or required to be maintained under Article 21 or regulations of the Environmental Management Commission Implementing that Article, or who falsifies, tampers with, or knowingly renders Inaccurate any recording or monitoring device or method required to be operated or maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, shall be guilty of a misdemeanor punishable by a fine not to exceed $25,000, or by imprisonment not to exceed six months, or by both. (18 U.S.C. Section 1001 provides a punishment by a fine of not more than $25,000 or imprisonment not more than 5 years, or both, for a similar offense.) Page 3 of 3 Version 5/2012 Public Water System (PWS) name: Town of Dallas Water Treatment Plant PWS ID: NC0082694 Water treatment plant name: Town of Dallas Water Treatment Plant Water system facility ID: TO1 Indicate the following on the diagram that best represents your facility type (if applicable) 1. Points of chemical treatment prior to the treatment plant 2. Filter backwash water addition 3. Pretreatment processes (e.g., Presedimentation basins, bank filtration) 4. Multiple source waters (show by adding additional sources 5. The Plant production at this time is 0.59 million gallons pre -day. 6. Waste water out put varies between 0.08 to 0.136 Earth Tech (Copper Sulfate) is added to reservoir year Raw Water Sample ID = SO2 Raw Water water Sample after Earth Tech addition Point is prior to chemical addition. \ Raw Water Sample Point before the addition of Earth Tech Sample ID= SO Raw Water Pump Station to Reservior ID zi Sol 0 i Plant uon a ' t::' .i Chemicals Fded in Flash — 5W.�2� �die `\: _\®��� ... . . 2 "Taod" :ƒ Page 1 of I Gaston County, NC Office of the Director of Revenue, GIS Division Disclaimer.The mformaton provided is not to de considered as a Legal Document or Descnpdon. The Map and Parcel Data is believed to be accurate. but Gaston County does not guarantee its accuracy. Vaiues oared on last general reappraisal - 2007 Print Oate: 31312010 Phmo \o; Avneoi: Prim Scale 1:5202 or 1p" = 436' b iy x %t -a T 24 K PARCEL INFORMATION undefined: urdefinea undefinea. undefined undefined undefined undefined: unrefined undefined: undefned undefined: undefined undefined: undefined undefined: undefined undefined: undefined undefined: unaefinea undefined 0 undefined: undefined undefined: undefined undefined: undefined undefined: undefined undefinedundefined undefined: undefined undefined: undefined undefined: undefined undefined. undefined ndefineo: undefined undefined: undefined undefined undefined lu undefined unrefined undefined: undefined undefined: undefined urulefineC'. undefined undefined: undefined undefined undefined undefined undefined undefined: unaefineo undefined: undefined undefined. undefined undefined unaefinea undefined: undefined undefined: undefined undefined: undefined http:/egovl.co.gaston.nc.usiservlet'com.esri.esrimap.Esrimap?ServiceName=MSOVERVI... 3/3/2010