Loading...
HomeMy WebLinkAboutNC0082767_Staff Report_19971024TO: PERMITS AND ENGINEERING UNIT WATER QUALITY SECTION Attention: Mack Wiggins W.47�R ni u, ��, ME V e D , DATE: October 24, 1997 OCT 2 9 NPDES STAFF REPORT AND RECOMMENDATIONSpharpF Fe mitfinn COUNTY Mitchell PERMIT NUMBER NC0082767 PART I - GENERAL INFORMATION 1. Facility and Address: Town of Spruce Pine Water Treatment Plant Post Office Box 189 Spruce Pine, North Carolina 28777 2. Date of Investigation: October 16, 1997 3. Report Prepared By: Michael R. Parker 4. Persons Contacted and Telephone Number: Larry Carver 704/765-3000 5. Directions to Site: From the intersection of Old U. S. Highway 19E (Oak Street) and Elm Street, travel northeast on Elm Street to its intersection with Reservoir Road. Turn left on travel approximately 0.1 mile to the water treatment plant site. 6. Discharge Point(s), List for all discharge points: Latitude: 35055'09" Longitude: 82003'38" Attach a USGS map extract and indicate treatment facility site and discharge point on map. U.S.G.S. Quad No. D10NE U.S.G.S. Quad Name Spruce Pine, N. C. 7. Size (land available for expansion and upgrading): 1 acre S. Topography (relationship to flood plain included): Mountainous Not subject to flooding. 9. Location of nearest dwelling: approximately 200 feet g 7s 10. Receiving stream or affected surface waters: Beaver Creek a. Classification: C-trout b. River Basin and Subbasin No.: FBP, 06 C. Describe receiving stream features and pertinent downstream uses: fishing, wading, fish and wildlife propagation PART II - DESCRIPTION OF DISCHARGE AND TREATMENT WORKS 1. Type of wastewater: % Domestic 100 % Industrial a. Volume of Wastewater: 0.015 MGD (Design Capacity) b. Types and quantities of industrial wastewater: Water Treatment Plant C. Prevalent toxic constituents in wastewater: Chlorine, aluminum d. Pretreatment Program (POTWs only): in development approved should be required not needed 2. Production rates (industrial discharges only) in pounds per day: NA a. Highest month in the past 12 months: lbs/day b. Highest year in the past 5 years: lbs/day 3. Description of industrial process (for industries only) and applicable CFR Part and Subpart: Water Treatment Plant Alum Sludge and filter backwash water. 4. Type of treatment (specify whether proposed or existing): It is proposed to discharge 15,000 gpd of decant water from a thickener which will receive filter backwash water and settling basin blow - down water from the water treatment plant. 5. Sludge handling and disposal scheme: Sludge from the thickener is proposed to be discharged to the Town of Spruce Pine's wastewater treatment plant. 6. Treatment plant classification (attach completed rating sheet): Class I. 7. SIC Codes(s): 4941 Wastewater Code(s): Primary 21 Secondary Main Treatment Unit Code: 51007 Page 2 N. i PART III - OTHER PERTINENT INFORMATION 1. Is this facility being constructed with Construction Grant funds (municipals only) ? 2. Special monitoring requests: 3. Additional effluent limits requests: 4. Other: PART IV - EVALUATION AND RECOMMENDATIONS The Town of Spruce Pine has made application for a discharge of wastewater from the water treatment plant. The wastewater will consist of decant water from the sludge thickener with an estimated flow of 15,000 g.p.d. They are proposing to discharge this to Beaver Creek which is classified C-trout waters. Ultimate disposal of the thickened solids will be discharged from the thickener to the Town of Spruce Pine's existing wastewater treatment facility. It does not appear that this wastewater will violate water quality and it is recommended that the permit be issued. Currently there is no direct discharge to surface waters. All wastewater are being discharged to the Town of Spruce Pine's wastewater treatment plant. Si nature of Report Preparer dz;i W er Qualit Regional Supervisor Date Page 3