Loading...
HomeMy WebLinkAboutWQ0023310_Monitoring - 03-2024_20240424Monitoring Report Submittal Permit Number#* Name of Facility:* Month: * March Report Information Type * GW-59 WQ0023310 Warsaw Sanitation Trailer Wash Year:* 2024 Upload Document* Warsaw MW 3-14-24.pdf PDF Only 437.03KB Please upload one PDF containing all applicable monitoring reports (i.e., NDMR, NDAR-1, NDAR-2, NDMLR, GW-59). Confirmation Email Address: * aelmore@smithfield.com Name of Submitter: * Amy Elmore Signature: ��IIYf �IiIYO�G Date of submittal: 4/24/2024 This will be filled in automatically Initial Review Reviewer: Wanda.Gerald Is the project number correct?* WQ0023310 Is the monitoring report accepted?* Yes No Regional Office* Wilmington Reviewer: _anonymous Review Date: 4/30/2024 SUBMIT FORM ON YELLOW PAPER ONLY • • DEPARTMENT OF ENVIRONMENTAL QUALITY - DIV. OF WATER RESOURCES GROUNDWATER QUALITY MONITORING: INFORMATION PROCESSING UNIT COMPLIANCE REPORT FORM 1617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 FACILITY INFORMATION Please Print Cleady or Type PERMIT Number: Expiration Date: 11130/2024 Facility Name: Warsaw SanitationTrailer Wash Non -Discharge WQ0023310 UIC NPDES Other Permit Name (if different): Facility Address: 2822 Hwy 24 West TYPE OF PERMITTED OPERATION BEING MONITORED Warsaw (Street) NC 28398 County Du lin P El Lagoon ❑Remediation: Infiltration Gallery (City) (State) (zip) ❑■ Spray Field ❑Remediation: Contact Person: David Nordin Telephone#: 910-293-3434 ❑ Rotary Distributor ❑ Land Application of Sludge Well Location/Site Name: land application site No. of wells to be sampled: 3 ❑ Water Source Heat Pump ❑ Other: from Permit) SAMPLING INFORMATION If WELL WELL ID NUMBER (from Permit): MW-1R Date sample collected: 3/14/2024 FIELD ANALYSES: WAS Well Depth: 15 ft. Well Diameter: 2 in. pH 00400: 4.4 units Temp. 000lo: 19.1 °C DRY at Depth to Water Level 82546: 6.9 ft. below measuring point Screened Interval: ft. to — ft. Spec. Cond. oo094: µMhos time of sampling, Measuring Point is ft. above land surface Relative M.P. Elevation: ft. Odor 000m: none check Volume of water pumped/bailed before sampling: 3(dry) gallons Appearance tan/clear here: ❑ Samples for metals were collected unfiltered: F YES El NO and field acidified: © YES El NO LABORATORY INFORMATION Date sample analyzed: 3/26/2024 Laboratory Name: Envirochem Certification No. 94 PARAMETERS NOTE: Values should reflect dissolved and colloidal concentrations. COD 00335 mg/L Nitrite (NO2) as N 00615 mg/L Pb - Lead 01051 ug/L Coliform: MF Fecal 31616 <1 Col /100mL Nitrate (NO3) as N 00620 5.93 mg/L Zn - Zinc 01092 mg/L Coliform: MF Total 31504 /100mL Phosphorus: Total as P oo665 <0.04 mg/L (Note: Use MPN method for highly turbid samples) Orthophosphate 70507 mg/L Other (Specify Compounds and Concentration Units): issolved Solids:Total 70300 61 mg/L Al - Aluminum o11o5 mg/L pH (Lab) 00403 units Ba - Barium 01007 ug/L TOC 00680 mg/L Ca - Calcium oo916 mg/L Chloride 00940 7 mg/L Cd - Cadmium 01027 ug/L Arsenic 01002 ug/L Chromium: Total 01034 ug/L Grease and Oils 00552 mg/L Cu - Copper 01042 mg/L ORGANICS: (by GC, GC/MS, HPLC) Phenol 32730 ug/L Fe - Iron 01045 ug/L (Specify test and method #. ATTACH LAB REPORT.) Sulfate 00945 mg/L Hg - Mercury 71900 ug/L Lab Report Attached? ❑ Yes (1) ❑ No (0) Specific Conductance 00095 µMhos K - Potassium 00937 mg/L VOC 7873 method # Total Ammonia oo6lo <0.2 mg/L Mg - Magnesium 00927 mg/L method # (Ammonia Nitrogen; NH, as N; Ammonia Nitrogen, Total) Mn - Manganese 01055 ug/L , method # TKN as N 00625 mg/L Ni - Nickel 01067 ug/L method # For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs: mg/L VOC Removal% GW-59 Rev.06-07-2018 SUBMIT FORM ON YELLOW PAPER ONLY • • DEPARTMENT OF ENVIRONMENTAL QUALITY- DIV. OF WATER RESOURCES GROUNDWATER QUALITY MONITORING: INFORMATION PROCESSING UNIT COMPLIANCE REPORT FORM • • • • 1617 MAIL SERVICE CENTER, RALEI GH, NC 27699-1617 FACILITY INFORMATION Please Print Clearty or Type PERMIT Number: Expiration Date: 11/30/2024 Facility Name: Warsaw SanitationTrailer Wash Non -Discharge WQ0023310 UIC Permit Name (if different): NPDES Other Facility Address: 2822 Hwy 24 West TYPE OF PERMITTED OPERATION BEING MONITORED Warsaw (Street) NC 28398 County Duplin ❑ Lagoon ❑Remediation: Infiltration Gallery (City) (State) (Zip) ® Spray Field ❑Remediation: Contact Person: David Nordin Telephone#: 910-293-3434 ❑ Rotary Distributor ❑ Land Application of Sludge Well Location/Site Name: land application site No. of wells to be sampled: 3 ❑ Water Source Heat Pump ❑ Other: from Permit SAMPLING INFORMATION If WELL WELL ID NUMBER (from Permit): MW-2R Date sample collected: 3/14/2024 FIELD ANALYSES: WAS Well Depth: 15 ft. Well Diameter: 2 in. pH 00400: 5.2 units Temp. 000lo: 16.9 eC DRY at Depth to Water Level 82546: 5.4 ft. below measuring point Screened Interval: ft. to — ft. Spec. Cond. 00094: µMhos time of sampling, Measuring Point is ft. above land surface Relative M.P. Elevation: ft. Odor 00085: none check Volume of water pumped/bailed before sampling: 4 gallons Appearance clear here:❑ Samples for metals were collected unfiltered: ( ] YES ❑ NO and field acidified: 0 YES ❑ NO LABORATORY INFORMATION Date sample analyzed: 3/26/2024 Laboratory Name: Envirochem Certification No. 94 PARAMETERS NOTE: Values should reflect dissolved and colloidal concentrations. COD 00335 mg/L Nitrite (NO2) as N 00615 mg/L Pb - Lead olo51 ug/L Coliform: MF Fecal 31616 <1 col /100mL Nitrate (NO3) as N 00620 0.06 mg/L Zn - Zinc 01092 mg/L Coliform: MF Total 31504 /100mL Phosphorus: Total as P 00665 0.06 mg/L (Note: Use MPN method for highly turbid samples) Orthophosphate 70507 mg/L Other (Specify Compounds and Concentration Units): issolved Solids:Total 703oo 59 mg/L Al -Aluminum oil o5 mg/L pH (Lab) o0403 units Ba - Barium 01007 ug/L TOC 00680 mg/L Ca - Calcium 00916 mg/L Chloride 0094o 25 mg/L Cd - Cadmium 01027 ug/L Arsenic 01002 ug/L Chromium: Total 01034 ug/L Grease and Oils 00552 mg/L Cu - Copper 01042 mg/L ORGANICS: (by GC, GC/MS, HPLC) Phenol 32730 ug/L Fe - Iron 01045 ug/L (Specify test and method #. ATTACH LAB REPORT.) Sulfate 00945 mg/L Hg - Mercury 71900 ug/L Lab Report Attached? ❑ Yes (1) ❑ No (0) Specific Conductance 00095 µMhos K - Potassium 00937 mg/L VOC 7873 method # Total Ammonia 00610 <0.2 mg/L Mg - Magnesium 00927 mg/L method # (Ammonia Nitrogen; N1­13as N; Ammonia Nitrogen, Total) Mn - Manganese 01055 ug/L , method # TKN as N 00625 mg/L Ni - Nickel 01067 ug/L method # For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs: mg/L VOC Removal% GW-59 Rev.06-07-2018 SUBMIT FORM ON YELLOW PAPER ONLY • • DEPARTMENT OF ENVIRONMENTAL QUALITY - DIV. OF WATER RESOURCES GROUNDWATER QUALITY MONITORING: INFORMATION PROCESSING UNIT COMPLIANCE REPORT FORM • • • • 1617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 FACILITY INFORMATION Please Print Clearly or Type PERMIT Number: Expiration Date: 1113012024 Facility Name: Warsaw SanitationTrailer Wash Non -Discharge WQ0023310 UIC Permit Name (if different): NPDES Other Facility Address: 2822 Hwy 24 West TYPE OF PERMITTED OPERATION BEING MONITORED Warsaw (street) NC 28398 County DU lln p El Lagoon ❑Remediation: Infiltration Gallery (City) (State) (Zip) BE Spray Field ❑Remediation: Contact Person: David Nordin Telephone#: 910-293-3434 ❑ Rotary Distributor ❑ Land Application of Sludge Well Location/Site Name: land application field edge No. of wells to be sampled: 3 ❑ Water Source Heat Pump ❑ Other: from Permit SAMPLING INFORMATION If WELL WELL ID NUMBER (from Permit): MW-3R Date sample collected: 3/14/2024 FIELD ANALYSES: WAS Well Depth: 15 ft. Well Diameter: 2 in. pH 00400: 4.8 units Temp. 000lo: 17.6 °C DRY at Depth to Water Level 82546: 7.5 ft. below measuring point Screened Interval: ft. to ft. Spec. Cond. 00094: µMhos time of sampling, Measuring Point is ft. above land surface Relative M.P. Elevation: ft. Odor 00085: none check Volume of water pumped/bailed before sampling: 3 gallons Appearance clear here:❑ Samples for metals were collected unfiltered: D YES ❑ NO and field acidified: M YES ❑ NO LABORATORY INFORMATION Date sample analyzed: 3/26/2024 Laboratory Name: Envirochem Certification No. 94 PARAMETERS NOTE: Values should reflect dissolved and colloidal concentrations. COD 00335 mg/L Nitrite (NO2) as N oo615 mg/L Pb - Lead o1051 ug/L Coliform: MF Fecal 31616 <1 col /100mL Nitrate (NO.) as N 00620 14 mg/L Zn - Zinc 01092 mg/L Coliform: MF Total 31504 /100mL Phosphorus: Total as P 00665 0.05 mg/L (Note: Use MPN method for highly turbid samples) Orthophosphate 70507 mg/L Other (Specify Compounds and Concentration Units): issolved Solids:Total 70300 139 mg/L Al - Aluminum 01105 mg/L pH (Lab) 00403 units Ba - Barium 01007 ug/L TOC oo68o mg/L Ca - Calcium oo916 mg/L Chloride 0094o 27 mg/L Cd - Cadmium 01027 ug/L Arsenic 01002 ug/L Chromium: Total 01034 ug/L Grease and Oils 00552 mg/L Cu - Copper 01042 mg/L ORGANICS: (by GC, GC/MS, HPLC) Phenol 32730 ug/L Fe - Iron 01045 ug/L (Specify test and method #. ATTACH LAB REPORT.) Sulfate 00945 mg/L Hg - Mercury 71900 ug/L Lab Report Attached? ❑ Yes (1) ❑ No (0) Specific Conductance 00095 µMhos K - Potassium 00937 mg/L VOC 7873 method # Total Ammonia oo6lo <0.2 mg/L Mg - Magnesium 00927 mg/L method # (Ammonia Nitrogen; NH3as N; Ammonia Nitrogen, Total) Mn - Manganese o1o55 ug/L method # TKN as N 00625 mg/L Ni - Nickel 01067 ug/L method # For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs: mg/L VOC Removal% GW-59 Rev.06-07-2018 GW-59A COMPLIANCE REPORT FORM Permit # WQ0023310 (Submit one each monitoring period with GW-59 forms.) 1 Enter date monitoring results were due. 6aW2024 Will this monitoring report (GW-59 and GW-59A) YES NO be submitted after the established due date? 2 Was any required information missing on the GW-59 report forms? YES NO 1F the answer to question 1 or 2 is "YES", list in the space provided below the well identification number(s) and explain the problems encountered in obtaining the required information. 3 Are any of the monitor wells in need of repair or maintenance (damaged casing, unlocked or missing cap, missing YES O identification plate, area overgrown, etc.)? If the answer is "Yes", contact the Regional Office for guidance. 4 Are any monitored constituents equal to or above the established standards? NO If the answer to question 4 is "NO", skip to section 8. If the answer to question 4 is "YES" list the affected wells individually with constituent(s) and concentration(s) exceeding standards in the space provided below: MW-1 R pH 4.4 units MW-2R pH 5.2 units MW-3R pH 4.8 units N 14 mg/L 5 For the constituents identified in question 4 above, have standards been exceeded previously for the tknuaNO same constituent(s) in the same well(s) in the last two years? if the answer to question 5 is "NO", skip to section B. If the answer to question 5 is "YES", list in the space provided below, each well with constituent(s) exceeding standards, concentration(s) reported, and sample collection date for each occurrence (for the last two years). MW-1 R pH 3-14-24 4.4 units 11-4-22 4.1 11-8-23 3.75 est units 7-9-22 4 (See attached) 7-8-23 3.4 3-4-22 5.5 3-8-23 4.3 6 Are the monitoring wells listed in section 5 located at or beyond the review boundary? YES NO If the answer is "YES", a groundwater quality problem maybe occurring. CONTACT THE REGIONAL OFFICE IMMEDIATELY FOR GUIDANCE. If the answer is "NO", monitoring wells maybe improperly located; contact the Regional Office. 7 Is the permittee implementing previously approved actions required by the Division involving this YES NO groundwater quality problem? If the answer to question 7 is "YES", describe those actions in the space provided below. If the answer to question 7 is "NO", contact the Regional Office within 90 da s• an evaluation may be required to determine the impact the waste disposal system is having at the review and compliance boundaries surrounding this facility. Failure to do so may subject the permittee to a Notice of Violation, fines, and/or penalties. 8 The person completing this portion (GW-59A) of the monitoring report should sign below and submit this form with GW-59 forms for required wells to the address provided at the top of the current GW-59 form. it "hereby acknowledge that the above information was evaluated and the information submitted`in this resort (Complianc eport GW-59A) is true and complete to the best of my knowledge. &-405iz4/24/2024 Signature of Permittee (or Authorized Agent) Date GW-59A 12/8/2003 Continued 5. MW-2R pH 3-14-24 5.2 units 11-8-23 4.3 7-8-2 3 3.8 3-8-2 3 6.1 7-9-2 2 4.6 3-4-22 6.2 MW-3R pH 3-14-24 4.8 units MW-3R N 3-14-24 14 mg/L 11-8-23 4.4 7-8-23 4 3-8-23 4.4 11-4-22 4.3 7-9-2 2 4.4 3-4-2 2 5.2 7-8-23 10.8 3-8-23 16.5 7-9-22 12 3-4-22 17.7