Loading...
HomeMy WebLinkAboutNC0083101_Authorization to Construct_20040405Mr. Robert Young City of Henderson P.O. Box 1434 Henderson, North Carolina 27536 Michael F. Easley, Governor State of North Carolina William G. Ross, Jr., Secretary Department of Environment and Natural Resources Alan W. Klimek, P.E., Director Division of Water Quality April 5, 2004 Subject: Authorization to Construct ATC No. 083101A01 NPDES Permit No. NCO083101 Vance County Dear Mr. Young: The Division of Water Quality's NPDES Unit has reviewed your request for an Authorization to Construct at the Kerr Lake Regional Water System. The Division finds the proposed improvements to be satisfactory and hereby grants authorization for the following: • Two 80 feet diameter thickeners, • Sludge pumping station with two progressive cavity sludge pumps, rated at 205 gpm, 59 ft TDH, • all related structures, equipment, piping, controls, and other appurtenances, as presented in the proposed plans and specifications. This Authorization to Construct is issued in accordance with NPDES Permit No. NC0083101, issued July 15, 2002 and shall be subject to revocation unless the wastewater treatment facilities are constructed in accordance with the terms and conditions of the permit. Special Conditions The permittee shall evaluate the sludge handling operations to eliminate the practice of cleaning and disposing spilled sludge from the loading pad by hosing to the adjacent grassy area. Within 90 days of the issuance of this Authorization to Construct the permitte shall submit to the Division a report summarizing the evaluation and proposed solutions. Notification The Permittee shall notify the Water Quality Supervisor of the Raleigh Regional Office, telephone number (919) 571-4700, at least forty-eight (48) hours prior to operation of the installed facilities, so that an in -place inspection can be made. Notification shall be made during the normal office hours of 8:00 a.m. until 5:00 p.m., Monday through Friday. Engineer's Certification Upon completion of construction and prior to operation of the modified facility, the Permittee shall provide the Division with a certification (copy enclosed) from a professional engineer registered in North Carolina certifying that the permitted facility has been installed in accordance with the NPDES Permit, this Authorization to Construct, and the approved plans and specifications. The Certification should be submitted to: NCDENR / DWQ, NPDES Unit, 1617 Mail Service Center, Raleigh, North Carolina 27699-1617. 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Telephone (919) 733-5083 FAX (919) 733-0719 An Equal Opportunity Affirmative Action Employer Internet: http://h2o.enr.state.nc.us/ Kerr Lake Regional Water System NPDES Permit No. NCO083101 ATC No. 083101 A01 Page 2 Requirements for Certified Operator The Permittee shall employ a certified wastewater treatment plant operator to be in responsible charge (ORC) of the wastewater treatment facilities. The operator must hold a certificate of the type and grade at least equivalent to or greater than the classification assigned to the wastewater treatment facilities by the Certification Commission. The Permittee must also employ a certified back-up operator of the appropriate type and grade to comply with the conditions of Title 15A, Chapter 8G, .0200. The ORC of the facility must visit each Class I facility at least weekly and each Class II, III, and IV facility at least daily, excluding weekends and holidays; and mustproperly manage and document daily operation and maintenance of the facility and comply with all other conditions of Title 15A, Chapter 8G, .0200. Additional Requirements The Operational Agreement between the Permittee and the Environmental Management Commission is incorporated herein by reference and is a condition of this Permit. Noncompliance with the terms of the Operational Agreement shall subject the Permittee to all sanctions provided by G. S. 143-215.6 for violation of or failure to act in accordance with the terms and conditions of this Permit. Failure to abide by the requirements contained in this Authorization to Construct may subject the Permittee to an enforcement action by the Division of Water Quality in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. The issuance of this Authorization to Construct does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. The Permittee shall maintain a copy of the approved plans and specifications on file for the life of the facility. One (1) copy of the approved plans and specifications is enclosed for your records. If you have any questions about this Authorization to Construct, please contact Teresa Rodriguez, at (919) 733-5083, extension 553. Sincerely, �kE� Alan W. Klimek Director Enclosures: Project Plans and Specifications (approved) Engineer's Certification Form cc: Raleigh Regional Office, Water Quality Technical Assistance and Certification Unit Central Files NPDES Unit Files Mr. David A. Cornwell, Ph. D., P. E. — Environmental Engineeringand Technology, Inc 712 Gum Rock Court Newport News, Virginia 23606 Date: _7 63 Time: 1 1. ZO ❑ Return ❑ Call to ❑ Call from Subject: TELEPHONE RECORD Project: 1 00nlO l Mr Mrs Waya (JcgcC Representing: Ve "v Address Telephone: _ �Z— `i'39— 2,1 4-1 FAX: NOTES/ SUMMARY '` kr hldai- lac 7 tW/vm. qJ1Ja3- 1'33 b6 - Ni u v j adtlice, Jt D o u 4 -,Joa - NEEDED FOLLOW-UP 1. ACTION(S) BY y, 14, WHOMIV114RH 9. 4. 4 5. cc: Signed ATC SUMMARY ATC No. 083101 A01 PERMIT NO NCO083101 FACILITY Kerr Lake Regional WTP COUNTY Vance County RECEIVING STREAM Anderson Swamp Creek BASIN Roanoke CLASS WS-III, B-CA REGIONAL OFFICE Raleigh APPLICATION/PLANS PREPARED BY: EE&T David A. Cornwell, P.E. 712 Gum Rock Court Newport News, Va SCOPE: Construction of two residual thickeners, a residual pump station, and polymer addition system to treat the backwash from the filters. SUMMARY: The Kerr Lake Regional Water System has a 15 MGD treatment capacity and utilizes Kerr Lake as the source of water. The water treatment system consists of flocculation, sedimentation and filtration. The filters backwash will be treated in the two thickeners. Settled sludge will go to storage lagoons or loaded in trucks for disposal. Originally they intended to convert the sand drying beds to lagoons but they didn't do the modifications. Effluent from the thickeners will be discharged to Anderson Swamp Creek. This ATC was requested after the project was completed. PROJECT EQUIPMENT DESCRIPTION: Two Batch thickeners — 80 feet diameter, with a capacity of approximately 458,000 gpd Thickener residual pump station with two progressive cavity pumps, with a capacity of 205 gpm Turbidity meter and flow meter RECOMMENDATIONS: The Raleigh Regional Office conducted an inspection and recommended the installation of an underdrain or containment structure for the sludge truck loading rack were sludge spills are cleaned by hosing to the grass. A special condition will be included in the AtC for the facility to evaluate the practice and submit a report with proposed solutions. NPDES Unit contact: Teresa Rodriguez EE&T ENVIRONMENTAL ENGINEERING & TECHNOLOGY, INC. August 30, 2001 Mr. Mike Myers NCDENR - NPDES Permit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Re: Kerr Lake Regional Water System Kerr Lake Regional Water Filtration Plant Residuals Handling Facilities NPDES Permit #NC0083101 Dear Mr. Myers: Rtc, W, 0t31u1 � C)\ In accordance with your recent telephone conversation with Mr. Todd Smith of our office, enclosed please find the following: • Three (3) sets of plan sheets related to the residuals handling facilities • Three (3) sets of technical specifications for the work • Design calculations related to Residuals Handling Facilities • Approval letter form NCDENR, Division of Environmental Health, Public Water Supply Section, dated 12/12/99, for the facilities On behalf of the Kerr Lake Regional Water System and the City of Henderson as Managing Partner, we hereby request that these facilities be added to the referenced NPDES Permit for the facility. If there are any questions or if additional information is required, please contact the writer or Mr. Todd Smith at 757-873-1534. Sincerely, ENVIRONMENTAL ENGINEERING & TECHNOLOGY, INC. j David A. Cornwell, Ph.D., P.E. President l o /slh GR cc: Mr. Mark Warren, City Manager, Henderson Mr. Michael Hicks, Director, Kerr Lake Regional Water System { o= Mr. Todd Smith, P.E., EE & T f P:\HendDeslFlnalDoc%LeBers"mO830011V wpd 712 gum rock court- newport news, virginia 23606 - (757) 873-1534 - fax: (757) 873-2392 ern NCDENR JAMES B. HUNT JR. RECEIVED J" 0 3 is 2Y. `� NORTH AROLINA DEPARTMENT OF rY ENVIRONMENT AND NATURAL RESOURCES GOVERNOR Mr. Michael A. Hicks Kerr Lake Regional Water System Post Office Box 1434 Henderson, North Carolina 27536-1434 BILL HOLMAN SECRETARY DIVISION OF ENVIRONMENTAL HEALTH PUBLIC WATER SUPPLY SECTION December 22, 1999 11 9� - f �Y Re: Kerr Lake Regional Water System Treatment Plant Improvements Vance County ID# 02-91-010 Dear Mr. Hicks: LINDA C. SEWALL Enclosed please find one copy of the "Application for Approval..." together with one copy of the DIRECTOR referenced plans and specifications bearing the Division of Environmental Health stamp of approval and signature of the Public Water Supply Section Chief for the referenced project. These plans and specifications are approved under Division of Environmental Health serial number 99-01039, dated December 21,1999. JESSICA G. MILES . CHIEF Plans and specifications prepared by David A. Cornwell, P.E., Roger G. Stroud, P.E., Thomas Ogden Fenn, P.E., and S.G. Roberts, P.E., call for the construction of residual collectors In the existing sedimentation basins, residuals thickeners, a thickened residuals pumping station, a sodium hypochlorite storage and feed facility, a raw water pump and other improvements to the Kerr Lake Regional Water Treatment Facility. The enclosed approval contains conditions on the project as follows: The maximum (design) 15 million gallons per day treatment capacity of the plant shall not be impaired any time during construction of this project. Public water system rules require that a registered professional engineer verify that construction has been completed in accordance with these approved plans and specifications. In order to complete the approval of this project, please furnish us a copy of the engineer's verification affixed with his/her profes- sional engineering seal immediately upon completion of construction. One copy of each enclosed document is being forwarded to our Raleigh Regional Office. The third copy is being retained in our permanent files. If we can be of further service, please call on us at (919) 733-2460. a rfe k1u6cTen, P.E., Head echnical Services Branch Public Water Supply Section JWM/SMCljhr Enclosures: Approval Documents cc: Michael L. Douglas, Regional Engineer Vance County Health Department ,Z-ftvironmental Engineering and Technology Jtl qsl GltlGA 2 Q 1 0 1634 MAIL SERVICE CENTER, RALEIGH, NORTH CAROLINA 27699-1634 PHONE 919-733-2321 MAIN FAX 919.715-4374 LAB FORMS FAX 919-715-6637 AN EQUAL OPPORTUNITY / AFFIRMATIVE ACTION EMPLOYER - 50% RECYCLED/10% POST -CONSUMER PAPER Kerr Lake Regional Water System Treatment Plant Priority I Improvements Prepared for Kerr Lake Regional Water System Henderson, North Carolina June1999 Prepared by EE&T '\(`-j ENVIRONMENTALENGINEERING &TECHNOLOGY, INC. 712 Gum Rock Court, Newport News, Virginia 23606 RESIDUALS THICKENERS Description: Two batch thickeners will collect spent filter backwash water and residuals from the sludge collectors. The thickeners will operate in a fill and draw mode. Decanting of settled backwash water is through pipes located along the sidewall of each thickener. Decant valves will have electric motor operators controlled from the plant's SCADA system. Number of thickeners 2 ' Surface area Each 5,026 ft2 - Total 10,052 ft2 Basin dimensions Inside diameter 80 ft Sidewall water depth 14.8 ft Total sidewall depth 16.4 ft Water depth at center pier 21.9 ft Floor slope 13/a to 12 Washwater volume Average 386,000 gpd Maximum 852,000 gpd Sludge volume 72,000 gpd Total volume (washwater + sludge) Average 458,000 gpd Maximum 924,000 gpd Maximum water level elevation 360.0 ft Usable volume One basin --- 458,000 gal Two basins 924,000 gal Detention time Average 38 hrs Maximum 18 hrs Residuals quantities Average 2,800 lb/d Maximum month 4,100 lb/d Thickened solids concentration 4 percent Thickened residuals volumes Average 8,393 gpd Maximum 12,290 gpd Sludge pocket volume One basin 73,000 gal Two basins 146,000 gal pAhenddeslfina1docldsgnspec.wpd RESIDUALS THICKENER (con't) Thickened residuals detention Average Maximum month Thickener inlet pipe Residuals draw -off pipe Decant pipe size Number of decant pipes per thickener Time to decant Thickener drive mechanism Manufacturer Horsepower Power requirement Torque p:lhenddesVinaidocldsgnspec.wpd 17.4 days 11.9 days 30/24 in. 6 in. 8 in. 2 8 hrs Eimco, Envirex 1.5 Hp 230/460 volt, 3 phase 50,000 ft. lbs foug"T M= Licht to ILS" V"%Whf we chew TO sun W2&PA N OME MAT r HANWAL IZmdes ALVEAW►rEwtwer tiE CD%PCLOA"W � ne► .EEa - r7�pir TO Sun r .r R AiIKM A'1E •� i0 T . 4orEn AEEOi ? its L` Q COMEROOM ILLUSTRATIVE QEVATION IZ/OOO LES� wTo Ta ' �,p �♦ t«.co roP OF WALL I 1 1 � f �` :e.• �� f.l tat'AT" Lwam KEO _ r. n /wt wam %FM fm PANLWr SCE wrEN OEPTH T O[O wAt" fWarteNT CO6/KMT IS DEMO vtw (LOSE coam ►Tdt TO AWWA / ASCE A DeNDATb6. L FM AMO UL OETALS SEE ORAMIQ MOO Q . S C *CttfE A/Q PWOATO/ OLSOL NO i+ EKa C. S M OWNTAUK AAO ELEVATO+ OP PPNw WK RE PM POOR" **mat "Is L TMS ORAWMO WKSEWTS A SKLL COOCKY UM kM CTfPGAArOL mw twas" 1CO VARATO/S OE3LV40 TO Sur fWK A/PLlCATO• KEGS AAe ►OSSKL RRR We %arm v..orTKS LIOA ►EM GA , 0.0 •pQ $• StaANLe75 STE(l s.lTEp(RS NSOE lAMM RAM OR TAW WALL RaoVS WEIR DETAIL D Me+to TANK BOTTOM DETAIL D Itetay 4{!-4 [W oR YftNAV 04 NAMPA& "a Aw *coo RAM TanlaTe rep op am, Lw9 AGSATAM STAKISS STM SO mmil ANOCA BMTS RAKE BLADE DETAIL ELEVATION} A I0 a' CKO 0 )(6 WALKWAY ENO OETAL 8 WALL MOUNTED WFLUENT PPE SUPPORT 0 rLGwP Fm Aftlu pom WEIMCO r CCI!= ECW% M CoawAW SLUO(IE TMCKENERS FOR wATM TV&ATUWr r•a Ims T.. I - . n.. w... «• .+....w w..w . M �.. � awr wTC ..awa.• « � �+arr « �wd ti r ..r o..• � fa � awn .a.r . �r ..wr • wrw ,aw aawn. «...� � r r raw .ram. • �rr>II w w .A a.•wr�a r ./ w.ar M •A DETAILS vT - GST s.UVA MLVENFa 9nioa. MEND 2 Kerr Lake Regional Water Treatment Plant Filter Back Wash Hydraulic Calculations Thickener W.S.E. = 358.60 Wxshwkter Tmugh Inv. El. = 383.25 Backwash Waste Rate IS gpm/sf Total Headlnss= 14.27 h Filter Area = "I sf H.G.L. St. @ W W Trough = 372.87 Backwash Waste Flnw= 7,939 gpm Available Hend= 10.38 ft C= IIk7 Sludge Thickener No.1 to the Filters (BackWash Waste) Item Nn. Description i Bend etc Diameter mchu Q m Q cu Naec A s Acmal Pipe Length 0 Velocity Nsec(It) WMI, Depth of Flnw R K R Head Lou it Hydraulic Profile Elevation Comments J " - - 359.60 Pull Conduit Flow 1 Exit 307938 17.69 4.91 3.60 0.202 1 0.202 358.80 2 Vertical Column 30 7938 17.69 4.91 20 3.60 0.044 358.85 3 90°Bend 30 7938 17.69 4.91 3.60 0.202 0.3 0.061 358.91 0 M 30 7,938 17.69 4.91 46 3.60 0.101 359.01 5 301 x 24" Reducer 24 7.938 17.0 3.14 5.63 0.493 0.291 35930 6 45-Van. Bend 24 7,938 17.69 3.14 5.63 0.493 0.2 0.099 359.11 7 pipe 24 7,938 17.69 3.14 12 5.63 0.078 359.IR R 45"Vest. Brad 24 7938 17.69 3.14 5.63 OA93 .eif'., 0.2 0.099 359.29 9 pion 24 1 7939 1 17.69 3.14 10 5.63 0.065 359.33 10 Butter0 Valve 24 7.938 17.69 3.14 5.63 O.493 0.46 0.227 35957 II Pi 24 7939 17.69 3.14 2 5.63 0.013 35959 12 30" x 24" Reducin Tee tench 24 7.939 17.69 3.14 5.63 0.493 IA 0.887 360.47 13 Pi 30 7.938 17.69 4.91 101 3.60 0.222 360.70 14 30- Tee (Run)$30 7.939 17.69 4.91 3.60 0.202 0.6 0.121 360.82 15 Pi 7938 17.69 4.91 59 3.60 0.130 360.95 16 30" x 6" Tee (Run)7,938 17.69 4.91 3.60 0.202 0.6 0.121 361.07 17 Pi 7.939 17.69 491 17 3.60 0.037 361.11 I8 45°Hortz Bead 7.939 17.69 4.91 3.60 0.202 0.2 0.040 361.15 19 Pi 7 938 17.69 4.91 23 3.60 Y:. 0.051 361.20 20 11 WVmBend 7938 17.69 4.91 3.60 0.202 0.1 0.020 361.22 Fofk lm 90"Band 21 Pi 7938 17.69 4.91 53 3.60 0.117 36133 22 11 WVe0. Bend 7938 17.69 4.91 - 3.60 0.202 0.1 0.020 361.35 44 ofk for 90° Bend 23 Pi 7938 17.69 4.91 134 3.0 0.295 361.65 24 Enlmrwe @ New 30" BW W7,938 17.69 4.91 3.60 0.202 0.5 0.101 361.75 Enterin Sluice Gate Chamber 23 Exit istin 30"R.C.P. 7.938 17.69 4.91 3.60 0.202 OWMAM 1 0.202 361.95 26 H.G.L. El. @ SM. Gate Chamber 1.38 36035 Transition to Open Channel Flow 27 Inv.1st @ Sluice Gate Chamber - 359.97 4.530 28 H.G.L. El. @ Manhole No.3 Out I38 364.88 29 Inv. Out @ Manhole No.3 36350 0.170 30 H.C.L. E. @ Manhole No. 31n 1.38 365.05 31 Inv. in @ Manhnle No.3 363.67 0.830 32 H.G.L El. @ Manhole No. 2 Out 139 365.98 33 Inv. Out @ Manhnlc No.2 36450 0350 34 H.G.L. El. @ Manhole Na. 21n 1.38 366.23 35 Inv. In @ M.hnlc Nm.2 364.85 0.121 36 pipe 30 7.938 17.69 4.91 55 3.60 0.121 366.35 Traasicnn to Full Conduit Flow 37 1 VA' Bend 30 7.938 17.69 4.91 3.60 0.202 0.1 0.020 366.37 38 30" x 24" Reducing Tee Run 30 7.938 17.69 4.91 3.60 0.202 0.6 0.121 366A9 T.Run Filter No. 1 39 Miss 30 7939 1 17.69 4.91 7 3.60 0.015 36651 40 30'x 12'Red.:k Tee un 30 7938 1 17.69 4.91 3.60 0.202 0.6 0.121 366.63 TwRun Filter 0 Waste - Filter No.1 41 Pim 30 7,938 1 17.69 4.91 13.5 3.60 0.030 366.66 42 30"x 24"Reducin Tte(Ron) 30 7938 17.69 4.91 3.60 0.202 0.6 0.121 366.79 Tee -Run - Filer No.2 43 Pi 30 7.939 17.69 4.91 7.5 3.60 0.016 366.90 44 301x I Ralucin Tee(Run) 30 1 7.938 17.69 4.91 3.60 1 0.202 0.6 0.121 366.92 Tee -Run Filter to Waste - Filter No.2 45 PiN 30 7.938 17.69 4.91 13.5 3.60 0.030 366.95 46 30" x 24" Reducio Tee(Run) 30 7,938 17.69 4.91 3.60 0.202 0.6 0.121 367.07 TmRun -Filler No.3 47 Fix:30 7,938 17.69 4.91 75 3.60 0.016 367.08 48 30"x 12'Rrducin Tx un 7,938 17.69 4.91 3.60 0.202 0.6 0.121 367.21 Tee -Run Filter to Waste - Filter No.3 49 Pi 30 7,938 17.69 491 IJ5 3.60 0.030 367.24 50 30"x 24' Redwing Ten ranch 24 7,938 17.0 3.14 5.63 0.493 1.8 0.987 368.12 Redtdn T.Bmnch - Filter No.4 51 Pi 24 7,938 17.69 3.14 1.5 5.63 0.010 368.13 52 Mal. Valve 24 7.938 17.69 3.14 5.63 0.493 S 2.463 37059 53 Pi 24 7.939 17.69 3.14 2.08 5.63 0.014 370.61 54 Backman 24 7938 17.69 3.14 5.63 0.493 0.5 0.246 Mae 1 14.27 1 Kerr Lake Regional Water Trmtment Plant Mer Beek Wash tlydnidie Cekulations Thickener W.S.E.= 359.60 WxshwaterTmugh Inv. El.= 383.25 Backwash Waste Ram= 23 giant Iof Total Headloss= 19.480 Filter Ann = 441 sf H.G.L. El. @ W W Tmugh = 378.08 Backwash Wage Flow = 10.143 gpnt Availahle Head = 5.17 6 C = HMI Sludge Thickener Ne.1 to the Filter (BaekWuh Waste) Room No. Description i Bend etc. Diamaa inches Q m Q cu Now A s Actual Pipe LengOl R Velocity Nsa V^]/2B R Depth ofFlnw fitB K Head LassProfile fl H)drulie Elevation CornmCnts - 35R.60 I Full Conduit Flow 1 Exit 30 IO,I4J 22.60 4.91 4.60 0.329 I 0.329 358.93 2 Vertical Column 30 10143 22.60 4.91 20 4.W 0.069 359.00 3 90'Bond 30 10.143 22W 4.91 4.60 0.329 0.3 0.099 359.10 4 pripc 30 10143 22.60 4.91 46 4.60 0.159 359.26 5 30" x 24" Reduces 24 10143 22.60 3.14 7.19 0.804 0.474 359.73 6 45' Vertt, Band 24 10143 22.60 3.14 7.19 0.804 0.2 0.161 359.42 7 Pipe 24 10143 22.0) 3.14 12 7,19 0.123 35954 R 1 45'Vert. Bend 24 10.143 1 22.W 3.14 7.19 0.804 0.2 0.161 359.70 9 Pipe, 24 10143 22.60 3.14 10 7.19 0.103 359.90 10 Bulterfl Valve 24 10.143 22.60 3.14 7.19 0.904 DAIS 0.370 360.17 II Pipe 24 10143 22.60 3.14 2 7.19 0.021 3W.20 12 30" x 24' Reducin Tee .h 24 10143 22.60 3.14 7.19 0.804 1.8 1.448 361.64 13 Pipe 30 10143 22.60 4.91 101 4.60 0.350 361.99 14 30"Tee Run 30 10.143 2260 4.91 4.60 0.329 0.6 0.198 362.19 15 pipc 30 10143 2260 4.91 59 4.60 0.204 362.39 16 30'x6"Ten tin 30 10143 22.60 4.91 4.W 0.329 0.6 0.199 36239 17 MDR 30 10.143 2260 4.91 17 4.60 _ 0.059 362.65 IB 45-Hatia Bend 30 10.143 2260 4.91 4.60 0.329 02 0.066 36232 19 Pipe 30 10,143 2260 4.91 23 4.60 0.080 362.80 20 11 s4' Vat. Bend 30 10.143 22.60 4.91 4.60 0.329 0.1 0.033 36283 %of k for 90' Band 21 Pi 30 10.143 22.W 4.91 53 4.W 0.184 363.01 22 11 44" Vert. Bend 30 10.143 22. W 4.91 4.60 0.329 0.1 0.033 363.05 th of k for90' Bend 23 Plan 30 10,143 220 4.91 134 4.60 0A64 363.51 24 Enhance (@ Nov, 30"BWW 30 10.143 22.60 4.91 4.W 0.329 0.5 0.165 363.68 Enterin Sluice GateChamha 25 Exit(Existing 30"R.C.P. 30 10143 22.W 4.91 4.60 0.329 I 0.329 364.00 26 H.G.L. El.@ Sluice Gam Chamfer 1.39 36035 Transition tnOpen Channel Flow 27 Inv. In @ Sluicc Gam Chamhcr 358.97 4530 28 H.G.L. El. @ Manhole No. 3 Out 1.38 364.88 29 Inv. Out @ Manhole Nn.3 363M 0.170 30 H.G.L. EL @ Manhole No. 31n 1.39 365.05 31 Inv. In @ Manhole Nn.3 363.67 0,930 32 H.G.L. El.@ Manhole No. 2 Out 1.39 365.88 33 Inv. 0.10 Manhole Nn.2 364.50 0.350 34 H.C.L. El. @ ManM1ole No. 2 In 1.38 366.23 33 Inv. In @ Manhole No.2 364.85 0.191 36 PiN 30 10143 22.60 4.91 55 4.60 0.191 366.42 Transition In Full Conduit Flnw 37 11W Bend 30 10.143 22.60 4.91 4.60 0.329 0.1 0.033 366.45 38 30' x 24' Redmin Tee(Run) 30 10,143 2260 4.91 4.60 0.329 0.6 0.198 366.65 TenRun Filter No. 1 39 Pim 30 10143 2260 4.91 7 4.60 0.024 366.68 40 30"x 12"Redumn Ten un 30 10143 22.60 4.91 4.60 0.329 0.6 0.198 366.87 Tec.Run Filkrm Waste-RitcoNn.1 41 Pin 30 10,143 2260 4.91 13.5 4.60 0.047 366.92 42 30"x24"Roducin Ten(Run) 30 1 I43 22.60 4.91 4.60 0.329 0.6 0.198 367.12 TwRon - Filter No.2 43 Pin 30 10.143 2260 4.91 7.5 M 0.026 367.14 as 30"x 12'RWudn Tee tin 30 10.143 2260 4.91 4.60 0.329 0.6 0.199 367.34 Tee -Ruh Films m Waste - Film, No.2 45 Mix, 30 10143 22W 4.91 13.5 4.60 0.047 367.39 46 30"x 24'Reducin Tee(Run) 30 10143 22.60 4.91 4.60 0.329 0.fi 0.199 36759 T.Run-Flm, No.3 47 Pipe 30 10,143 2260 4.91 7S 4.60 0.026 367.61 48 30'x I Redaniv Tee(Run) 30 10.143 2260 4.91 4.60 0.329 0.6 0.198 367.81 1 T.Ran Fllta to Wean -She, No.3 49 pip, 30 10 I43 22W 4.91 13.5 4.60 0.047 367.96 50 30'x 24'Reducing Tm rnacM1 24 IM43 2260 11 3.14 7.19 QRM 1.8 1.448 369.30 Reducing: Tee-Beaach - Filmy No.4 51 Pipe 10,143 22W 1 3.14 1.5 7.19 0.015 369.32 52 Angle Volvo 24 10143 22.60 3.14 7.19 0.1104 5 4.W1 37330 53 Pi 21 10143 22.W 3.14 2.0R 7.19 0.021 37336 54 Eanown 21 10,143 22.60 3.14 7.19 0.mm 0.5 0.402 373.76 19.49 KERR LAKE REGIONAL WTP 30" Backwash Waste Pipe Hydraulics Pipe Diameter= 30 in (INPUT) 2.5 ft Pipe Radius= 1.25 It 15 in Q minimum= 7938 gpm (INPUT) 17.69 cfs Q average= 9041 gpm (INPUT) 20.14 cfs Q maximum= 10143 gpm (INPUT) 22.6 cfs Manning's n= 0.013 (INPUT) Invert Out @ MH No.2= 364.5 Invert In @ MH No.3= 363.67 Elevation Difference= 0.83 Distance= 108 Slope, S= 0.0077 Calculating ARA2/3 for Q min, Q avg, Q max, and Cabs ARA2/3 @ Q min= 1.761 yV%= kc D% (%-V ) ARA2/3 @ Q avg= 23 yn- IC.15 C\.St') AR42/3 @ Q max= 2.25, In c Yl.. 4.L Cl,4d0 0.2 2.4 1.15 0.19 1.44 0.13 0.05 0.3 3.6 1.41 0.33 1.76 0.19 0.11 0.4 4.8 1.65 0.51 2.06 0.25 02 0.5 6 1.85 0.69 2.31 0.3 0.31 0.6 7.2 2.05 0.91 2.56 0.36 0.46 0.7 8.4 2.23 1.12 2.79 0.4 0.61 0.8 9.6 2.41 1.36 3.01 0.45 0.8 0.9 10.8 2.57 1.59 3.21 0.5 1 1 12 2.74 1.84 3.43 0.54 1.22 1.1 13.2 2.9 2.08 3.63 0,57 1.43 1.2 14.4 3.06 2.33 3.83 0.61 1.68� 1.3 15.6 3.22 2.58 4.03 0.64 1.92 1.4 16.8 3.38 2.83 4.23 0.67 2.171 1.5 18 3.54 3.07 4.43 0.69 2.4 1.6 19.2 3.71 3.32 4.64 0.72 2.67 1.7 20.4 3.88 3.56 4.85 0.73 2.89 1.8 21.6 4.05 3.78 5.06 0.75 3.12 1.9 22.8 4.24 4.01 5.3 0.76 3.34 2 24 4.43 4.21 5.54 0.76 3.51 2.1 25.2 4.64 4.4 5.8 0.76 3.66 2.2 26.4 4.87 4.58 6.09 0.75 3.78 2.3 27.6 5.14 4.73 6.43 0.74 3.87 2.4 28.8 5.48 4.84 6.85 0.71 3.85 2.5 30 6.28 4.91 7.85 0.63 3.61 NOR M DPTH. W K4 r C 0 c 3 2.5 6 1 0.5 Normal Depth for 30" Diam. Backwash Waste Pipe 0 0.5 1 1.5 2 2.5 3 3.5 4 ARA2/3 J c� NORMDPTH.WK4 OWN IN W-A El- If I-o � tttttf t� ti � � l t f � ttt� tti ti � � ! ! t � tttt� t� ti ttl � ■ ■ I — t� tt� t� � t♦ tl ! t � — � � at � tl t{ ■ ��lrwtlltf��®�t'.>!�m!■i����t♦i/■t-����i■lf=i!►i �=aONE �Ir���l��ei�/1®f�rOO■��1�® ,err �����®111®1����1lI�I��i�111�1Y■®�1!i� mom1l1111®mmmilli immon11111�O�1FUll �r�,ill -■�111111�■■I11111®�®Illllt�.Pep;p;rn� 1111 3.000.3pN-0 ��I�;0 —�sf6 t�lt�r1� 1111 //®0 ��itrii0l�.- ii���®r!f■ ®rttOtit■APS■!//-I��i■ti=P,:.. �lttf�ill�■ - �1•���'s!s�./-��/.�i�■ f�ttt�isdttf�i!■■ _._ .. .._ tewt�/1��t1��a��ttt►i1/i�A�■11-�i���Il1� � ,. ' ��illl�®�t�l11111l���011lit �totstsstsot��wsao�®r_.tri�ar�r:��trt�t�rt�����f�ttttt� c !fill =20MU!Mons ttt=rimtfate►.*��ttt■■t�o�tst.�!■���f =sots OMEN �■�11111■1�■■�1�./.�il��®11�■!!s®11gs1!®®S!®tie ®i■ile 111®®®®milli Now 1 IIt: IRIIVAff1wdAREWIN1[a/IR1 3 t] Pipe Diameter= Pipe Radius= Q minimum= Q average= Q maximum= Manning's n= Invert Out @ MH No.3= Invert In @ Sluice Gate Chamber - Elevation Difference= Distance= Slope, S= KERR LAKE REGIONAL WiP 30" Backwash Waste Pipe Hydraulics 30 in 2.5 ft 1.25 It 15 in 7938 gpm 17.69 cfs 9041 gpm 20.14 cfs 10143 gpm 22.6 cfs 0.013 363.5 358.97 4.53 175 0.0259 Calculating ARA2/3 for Q min, Q avg, Q max, and Qabs : AIR A2/3 @ Q min= 0.96 AIR A213 @ Q avg= 1.09 ARA2/3 @ Q max= 1.23 (INPUT) (INPUT) (INPUT) (INPUT) (INPUT) 0.2 2.4 1.15 0.19 1.44 0.13 0.05 0.3 3.6 1.41 0.33 1.76 0.19 0.11 0.4 4.8 1.65 0.51 2.06 0.25 0.2 0.5 6 1.85 0.69 2.31 0.3 0.31 0.6 7.2 2.05 0.91 2.56 0.36 0.46 0.7 8.4 2.23 1.12 2.79 0.4 0.61 0.8 9.6 2.41 1.36 3.01 0.45 0.8 0.9 10.8 2.57 1.59 3.21 0.5 1 1 12 2.74 1.84 3.43 0.54 1.22 1.1 13.2 2.9 2.08 3.63 0.57 1.43 1.2 14.4 3.06 2.33 3.83 0.61 1.68 1.3 15.6 3.22 2.58 4.03 0.64 1.92 1.4 16.8 3.38 2.83 4.23 0.67 2.17 1.5 18 3.54 3.07 4.43 0.69 2.4 1.6 19.2 3.71 3.32 4.64 0.72 2.67 1.7 20.4 3.88 3.56 4.85 0.73 2.89 1.8 21.6 4.05 3.78 5.06 0.75 3.12 1.9 22.8 4.24 4.01 5.3 0.76 3.34 2 24 4.43 4.21 5.54 0.76 3.51 2.1 25.2 4.64 4.4 5.8 0.76 3.66 2.2 26.4 4.87 4.58 6.09 0.75 3.78 2.3 27.6 5.14 4.73 6.43 0.74 3.87 2.4 28.8 5.48 4.84 6.85 0.71 3.85 2.5 30 6.28 4.91 7.85 0.63 3.61 NORMDPTH.WK4 3 2.5 2 i 1 0.5 0—C 0 formal Depth for 30" Diam. Backwash Waste Pip( `Jh � 233e�IsF = �•� 0.5 1 1.5 2 AR^2/3 2.5 3 3.5 4 NORMDPTH.WK4 �m �W-�l 011111115 0_1F Ito t�tlfatlt!/-tltt•ttl t■tl tlQt �t�ttt•t�a�Qtl/�tt• �fa��t,r■ t■���r�e.r■■t/®®ate■sera■■�®■4o■mw■�re■r_s�,r�■■■■�fs■ir ■■.: pp ■�■��rtr■■■�■■rare■��r�■■�o��a�r■■■■r.�■���r■■■■w� ®®■eye■■move®!=MEN movi1-o■1Mongol ®em®m■■ile®� :Nip Owww�,lllww®w■■�111-www■/�Il�wwww�l!:� :itl w�www�t�11®wwww„�i�ww®e■,���iww®ww,.��l ��,;il� aRPNRPP"wM2%020m9111 aaaa■■■tt a�aa■ w■ ®� l� b ► •d t/5�� �® d LaZ a� O O Q ! .iit, tt� t� fait i� n o f ■ ■i■aaaaaa■,■ zivw s W m ►. as ! iii �i arr t■ st ► ■ a■■e,■ ■tom aaa■ aaw a■ ■ a+■ ■ :ate■■■es■�MMEsoon s■ �r i:i�lw�ww ■����Iswww����� ® , •�:�' .��®111!�®®�®llllwwwwwsllll rpi- ■■■B=fl��wwlllll�■®111111 �aaaaaama aaaaaaa ■■ar . � a � � �� as ■s � o � ■ aaa■/a■� aaarv: v. � ■/ r � . � taaaaaa�a- aaa■�a e• r t■. e. � ■ ■r■te•� ■t ■ w ■ f ®tt■■�t■faf✓f�aleifai�a!/tf�t��a���off ��siar�■■■ss4•.ia�e�■■■■��■w■��r■■■■�■mmannom rya■■ ■®ee�e■®■■��e®i®ee.s�■®��9��ee■���®et�tesee� iii ii ®ww®I'-i���®�w�®lll�wiw®E1111® Billl ®���eiill wwlll�l�®w11111i®®■I11!!l w®Illili I It:I"I II'mMa I"W;l ■1[a o LNn 05/27/99 Kerr Lake Regional Water Treatment Plant Hydraulic Calculations i Supernatant Flow = 490.00 gpm C = 100 Max elevation = 14.36 Min Elevation = 2.18 j Calc Elevation = 2.18 j Supernatant Line @ Invert Elevation 356.42 I' Item No. Description (Pipe, Bend, etc.) Diameter (inches) Q m) Q (cu ft/sec) A (SO Actual Pipe Length �'rlocity (ft) (.,Vsec)' V^2/2g (ft) K (ft) Head Loss (ft) Accumulated Head Loss (ft) l Inlet 8 490.00 1.09 0.35 3.13 0.152 1 0.152 0.152 2 Pie 8 490.00 1.09 0.35 2.75 3.13 0.152 0.143 0.022 0.174 3 Plug Valve 8 490.00 1.09 0.35 3.13 0.152 0.217 0.033 0.207 4 Pie 8 490.00 1.09 0.35 6 3.13 0.152 0.312 0.047 0.254 5 Tee (Branch) 8 490.00 1.09 0.35 3.13 0.152 1.8 0.274 0.528 6 Pie 8 490.00 1.09 0.35 4.75 3.13 0.152 0.247 0.038 0.566 7 Tee (Branch) 8 490.00 1.09 0.35 3.13 0.152 1.8 0.274 0.839 8 Pie 8 490.00 1.09 0.35 2.5 3.13 0.152 0.130 0.020 0.859 9 Tee ranch 8 490.00 1.09 0.35 3.13 0.152 1.8 0.274 1.133 10 90°Bend 8 490.00 1.09 0.35 3.13 0.152 0.8 0.122 1.254 11 90° Bend 8 490.00 1.09 0.35 1 3.13 0.152 0.8 0.122 1.376 12 Pie 8 490.00 1.09 0.35 5.75 3.13 0.152 0.299 0.046 1.421 13 Flow Meter 8 490.00 1.09 0.35 3.13 0.152 0.6 0.091 1.513 14 Pie 8 490.00 1.09 0.35 2.00 3.13 0.152 0.104 0.016 1.528 15 90° Bend 8 490.00 1.09 0.35 3.13 0.152 0.8 0.122 1.650 16 Pie Inside through P.S. Wall) 8 490.00 1.09 0.35 4.75 3.13 0.152 0.247 0.038 1.688 17 Pie Outside into MH No. 1) 8 490.00 1.09 0.35 43.00 3.13 0.152 2.239 0.340 2.028 18 Exit (into MH No. 1) 8 490.00 1.09 0.35 i3.13 0.152 1 0.152 2.180 i Highest Water elevation 360 Manhole invert 345.64 Max. Available Static Head 14.36 Elevation of Lowest Decant Pipe 347.82 Min. Available Static Head 2.18 i DECANTHY.WK4 08:55 AM 05/27/99 Kerr Lake Regional Water Treatment Plant Hydraulic Calculations Supernatant Flow = 1279.00 gpm C = 100 Max elevation = 14.36 Min Elevation = 2.18 Calc Elevation = 14.34 Supernatant Line @ Invert Elevation 356.42 Item No. Description (Pipe, Bend, etc.) Diameter (inches) Q m) Q (cu ft/sec) A (sf) Actual Pipe Length Velocity (ft) (ft/sec) VA2/2g (ft) K (ft) Head Loss (ft) Accumulated Head Loss (ft) Inlet 8 1279.00 2.85 0.35 8.16 1.036 1 1.036 1.036 2 Pie 8 1279.00 2.85 0.35 2.75 8.16 1.036 0.124 0.129 1.164 3 Plug Valve 8 1279.00 2.85 0.35 8.16 1.036 0.217 0.225 1.389 4 Pipe 8 1279.00 2.85 0.35 6 8.16 1.036 0.271 0.281 1.670 5 Tee (Branch) 8 1279.00 2.85 0.35 8.16 1.036 1.8 1.864 3.534 6 Pie 8 1279.00 2.85 0.35 4.75 8.16 1.036 0.215 0.222 3.757 7 Tee (Branch) 8 1279.00 2.85 0.35 8.16 1.036 1.8 1.864 5.621 8 Pie 8 1279.00 2.85 0.35 2.5 8.16 1.036 0.113 0.117 5.738 9 Tee (Branch) 8 1279.00 2.85 0.35 8.16 1.036 1.8 1.864 7.603 10 90° Bend 8 1279.00 2.85 0.35 8.16 1.036 0.8 0.829 8.431 11 90° Bend 8 1279.00 2.85 0.35 8.16 1.036 0.8 0.829 9.260 12 Pie 8 1279.00 2.85 0.35 5.75 8.16 1.036 0.260 0.269 9.529 13 Flow Meter 8 1279.00 2.85 0.35 8.16 1.036 0.6 0.621 10.151 14 Pie 8 1279.00 2.85 0.35 2.00 8.16 1.036 0.090 0.094 10.244 15 90° Bend 8 1279.00 2.85 0.35 8.16 1.036 0.8 0.829 11.073 16 Pi Inside through P.S. Wall 8 1279.00 2.85 0.35 4.75 8.16 1.036 0.215 0.222 11.295 17 Pipe (Outside into MH No.l 8 1279.00 2.85 0.35 43.00 8.16 1.036 1.943 2.012 13.307 18 Exit into MH No.l 8 1279.00 2.85 1 0.35 " " ' "' ' 8.16 1.036 1 1 1 1.036 1 14.343 1 ! 4.34 1 Highest Water elevation 360 Manhole invert 345.64 Max. Available Static Head 14.36 Elevation of Lowest Decant Pipe 347.82 Min. Available Static Head 2.18 DECANTHY.WK4 08:55 AM THICKENED RESIDUALS PUMP STATION Description: A thickened residuals pump station will transfer the residuals from the thickener to either (1) the truck loading station or (2) the residuals storage basins. The pump station will also house the polymer feed systems for the thickeners. Number of pumps 2 Manufacturers Moyno Pump type Progressive cavity Model number 1F065 (Moyno) without overhung motor Driver Constant speed Weight (each) 955 lbs Capacity 205 gpm Differential pressure 23.4 psi Speed 450 rpm Horsepower 15 Hp Power 480 volt, 60 Hz Connection sizes Suction 8 in. Discharge 8 in. Seal water piping Inlet 1/2 in. Outlet 1/2 in. Time to load a truck 2,000 gal 10 min 3,000 gal 15 min 4,000 gal 20 min p:\henddes\finaldoc\dsgnspec.wpd